all | frequencies |
|
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|---|
manuals | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User Manual | Users Manual | 2.81 MiB | October 25 2022 / April 10 2023 | delayed release | ||
1 |
|
User Manual | Users Manual | 3.60 MiB | October 25 2022 / April 10 2023 | delayed release | ||
1 |
|
Internal Photos | Internal Photos | 3.58 MiB | October 25 2022 / April 10 2023 | delayed release | ||
1 |
|
External Photos | External Photos | 838.72 KiB | October 25 2022 / April 10 2023 | delayed release | ||
1 |
|
ID Label and Location | ID Label/Location Info | 473.41 KiB | October 25 2022 / November 01 2022 | |||
1 |
|
Agency Letter | Cover Letter(s) | 84.97 KiB | October 25 2022 / November 01 2022 | |||
1 | Antenna Gain Info | Operational Description | October 25 2022 | confidential | ||||
1 | Block Diagram | Block Diagram | October 25 2022 | confidential | ||||
1 |
|
Confidentiality Letter | Cover Letter(s) | 101.84 KiB | October 25 2022 / November 01 2022 | |||
1 | Operational Description | Operational Description | October 25 2022 | confidential | ||||
1 | Parts List | Parts List/Tune Up Info | October 25 2022 | confidential | ||||
1 | Schematics | Schematics | October 25 2022 | confidential | ||||
1 |
|
Test Report | Test Report | 1.29 MiB | October 25 2022 / November 01 2022 | |||
1 |
|
Test Report Appendix | Test Report | 3.00 MiB | October 25 2022 / November 01 2022 | |||
1 |
|
Test Setup Photos | Test Setup Photos | 1.12 MiB | October 25 2022 / April 10 2023 | delayed release |
1 | User Manual | Users Manual | 2.81 MiB | October 25 2022 / April 10 2023 | delayed release |
Model: V7232-3 / V7232-8 User Manual Thank you for choosing our products. Please read the instructions carefully before installation and keep it available for future maintenance or reference. Content S p e c i f i c a t i o n P a r a m e t e r e M a i n t e n a n c e O t h e r s Safety instructions Technical specification Parts identification Lid auto open/close Maintenance 1. Main unit care and maintenance 2. Spray nozzle care and maintenance 3. Filter maintenance Emergency troubleshooting 1. Power and water failure 2. Failure of remote control Description of the knob function LED display description Only for the toilet with LED display Troubleshooting guide 01 03 05 06 07 08 09 10 11 SAFETY INSTRUCTIONS When using electrical products, especially when children are present, basic safety precautions should always be followed, including the following:
1. The appliance is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction. 2. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. 3. Children shall not play with the appliance. 4. Cleaning and user maintenance shall not be made by children without supervision. READ ALL INSTRUCTIONS BEFORE USING DANGERTo reduce the risk of electrocution:
1. Do not place or store product where it can fall or be pulled into a tub or sink. 2. Do not place in or drop into water or other liquid. 3. Do not reach for a product that has fallen into water. Unplug immediately. 4. Do not wash the main unit or electrical plug with water or detergent. 5. Do not handle the electrical plug with wet hands. 6. Never block the outlet of the air dryer. 7. Never disassemble, repair or modify this product. 8. During installation, disassembly, repair and maintenance of the product, the power plug must be switched off and water supply be shut off. WARNING To reduce the risk of burns, electrocution, fire, or injury to persons. 1. Close supervision is necessary when this product is used by, on, or near children or individuals with disabilities. 2. Use this product only for its intended use as described in this manual. Do not use attachments not recommended by the manufacturer. 3. Never operate this product if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water. Return the product to a service center for examination and repair. 4. Keep the cord away from heated surfaces. 5. Never use while sleeping or drowsy. 6. Never drop or insert any object into any opening or hose. 7. Do not use outdoors or operate where aerosol (spray) products are being used or where oxygen is being administered. 8. Connect this product to a properly grounded outlet only. See Grounding Instructions. 9. Do not throw cigarettes and other burning materials into toilet, otherwise it might cause fire. 10. This product is an electric appliance, so it must be placed far away from water and other liquid. 11. Do not lay the product on its side or upside down during the electrical circuit. 12. It is prohibited to use other electric appliances in the same socket. 13. It is forbidden to use the power extension or unstable loose outlet. 14. Do not reuse any existing water supply hoses, otherwise it might cause leakage, fire or electrical shock. Installation should include specified components and a new water supply hose. 01 IMPORTANT SAFETY INSTRUCTIONS CAUTION Failure to follow the instructions may cause bodily injury or property damage. 1. Do not install or use the product in wet places such as a steam room etc. 2. It is recommended to use water-proof electrical outlet which should be installed in a place where is not easily to get wet. 3. This product should be used with 110V-120V, 50/60Hz electrical current only, load current is at least 15A. Power plug must be equipped with ground fault circuit interrupter or ground fault electrical leakage protector or similar high sensitive, rapid type leakage switch. (Rated sensitive current under 6mA). 4. When it thunders, it is strongly recommended to pull out the power plug. 5. Do not stand on product unit, seat and lid. 6. Do not lean against the lid when using the product, to avoid damage. 7. This product is equipped with a soft-closing seat and lid. Do not push the toilet seat closed, or damage may occur. 8. Do not use any caustic chemicals or scrubbing brush to clean this product. 9. Exposure to direct sunlight is prohibited. 10. Only use tap water or potable water; otherwise it may cause chafing. 11. Do not connect water supply to a hot water supply. Make sure inlet water temperature is between 3~35/37.4~95. 12. Raise room temperature to prevent the toilet from damage due to freezing. 13. When not using the product over three(3) days, drain the water out of the toilet and pull the electrical plug from the wall outlet. 14. Stop using the product and shut off the power when product malfunctions. Call for professional service. 15. Means for full disconnection must be incorporated in series in the power input loop of the same room where the product is installed, that is at the front end of the fixed wiring to ensure safe use. GROUNDING INSTRUCTIONS This product should be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electrical current. The plug must be plugged into an outlet that is properly installed and grounded. DANGER Improper use of the grounding plug can result in a risk of electric shock. If repair or replacement of the cord or plug is necessary, do not connect the grounding wire to either flat-head terminal. Check with a qualified electrician or serviceman if the grounding wire instructions are not completely understood, or if in doubt as to whether the product is properly grounded. This product is factory equipped with a specific electric cord and plug to permit connection to a proper electric circuit. Make sure that the product is connected to an outlet having the same configuration as the plug. No adapter should be used with this product. Do not modify the plug provided if it will not fit the outlet, please have the proper outlet installed by a qualified electrician. If the product must be reconnected for use on a different type of electric circuit, the reconnection should be made by qualified service personnel. SAVE THESE INSTRUCTIONS 02 Technical specification Model Rated voltage Rated power Water proof Main Unit V7232-3 / V7232-8 110V-120V, 50/60Hz 905W IPX4 Water pressure range 0.08MPa - 0.8MPa (static pressure) Flush volume Flushing mode 1.6/1.1Gpf, 6.0L(full flush) /4.2L(half flush) Washdown Toilet Outlet height 212mm Outlet outside diameter 102mm Drainage method Heating power P-trap 1400W Water temperature 6-level adjustment (Neutral level included) Water volume 3-level adjustment Cleaning mode Rear washing /Oscillating washing, Front washing /Oscillating washing Cleaning device Nozzle position 5-level adjustment Water pressure protector Pressure maintaining device, Automatic pressure relief device Anti-fouling device Automatic nozzle cleaning, Anti-syphon device, Anti-backflow device, Filter device Safety device Thermal fuse, Water temperature sensor, Ground protection, Thermostat, Over temperature protection, Leakage protection device Warm air speed Over 4m/s Drying device Warm air temperature 6-level adjustment (Neutral level included) Heating power Safety device 200W Thermal fuse, Leakage protection device, Thermostat Deodorization
(optional) Sterilization
(optional) Deodorization method Photocatalyst-free Sterilization device Plasma sterilization Surface temperature 6-level adjustment (Neutral level included) Heating power 50W Heated seat Burn protection Safety device After 10 minutes of use, the seat temperature will automatically drop slowly to a low level Seat sensor, temperature sensor, thermal fuse, thermostat, leakage protection device 03 Night light assembly Intelligent, Always on, Always off Noise-free setting The buzzer is off at night for a quiet environment. User ID setting To avoid interference when used by multiple users Caring device Automatic flushing Toilet will automatically flush as user walks away from bowl. Foot sensor function
(optional) Activate lid opening (optional) Activate a half flush (optional) Difference description Lid opening
(optional) Soft close Lid auto-open Antibacterial site Seat, Nozzle Rated power:
Under the condition of ambient temperature 23/73, water static pressure 0.18MPa0.02MPa, water temperature 15/59, power toilet on, set water pressure, seat temperature, water temperature to the highest level in turn and perform one rear washing cycle. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. The remote control operates at 2.4 GHz frequency. The main unit performs corresponding function upon the signal from remote control. The lid auto open sensor module operates at 24 GHz frequency. The module will sense movement and open the lid when approached.(Only for the product with lid auto opening/
closing function) 04 Parts identification Left side Lid Knob Right side Drying shield Nozzle shield Spray nozzle Rear washing Front washing Bumper Seat Ceramic toilet Touch the sensing area with foot
(optional) Bumper Night light sensor 05 Lid auto open/close 1. Only for the product with lid auto opening/closing function. This function is turned off by default. For the first use, please turn on this function by remote control. 1. Approaching the toilet When user enters the sensing range, the ECO lights up and the lid opens automatically. 2. Leaving the toilet The lid closes automatically 180 seconds after user leaves. 2. If the model you purchased is with foot sensor, 1. When the seat and lid are both closed, touch the sensing area with your foot to open the lid. 2. When the lid is open and seat is closed, touch the sensing area with your foot to close the lid and activate a half flush. 3. When the seat and lid are open, touch the sensing area with your foot to activate a half flush. 06 Maintenance Main unit care and maintenance 1. Shut off power supply before doing maintenance. 2. Use only a soft, damp cloth to clean. Avoid using harsh chemicals. Spray nozzle care and maintenance 1. When no one is seated, turn the knob clockwise. The nozzle will automatically stretch out to allow access for cleaning. 2. When the nozzle moves forward, the nozzle can be removed and cleaned separately. 3. Use only a soft cloth or soft brush to clean. Do not pull or push the wand, to avoid damage. 3. Once cleaning is completed and all surfaces are dry, re-connect the power plug. 4. Put the nozzle back and press the knob to return the spray wand to its normal position. Note:
The spray wand will retract automatically after 10 minutes or if the seat is used. 07 Emergency troubleshooting Filter maintenance If poor spray performance occurs under normal conditions:
1. Turn off power and ball valve, unscrew water supply hose. Power and water failure Put around 8L water into a barrel and flush the ceramic bowl. Note: Avoid water spilling from bowl. Failure of remote control 1. Operate via knob on the main unit. Connect the end of the bidet 2. Remove the filter. 3. Clean out filter under running water. 4. Reinstall filter and water supply hose, turn on ball valve and connect power. 2. Battery replacement Remove the remote control from holder. Open the battery cover and replace the batteries. Put the remote control back. Note:
After battery replacement, the settings of auto functions and energy saving will be restored to the defaults. Please reset. 08 Description of the knob function 1. When seated, turn the knob clockwise to start front washing function, and turn counterclockwise to start rear washing function. Drying and flushing function are activated automatically after first washing completion or pressing knob during washing. When washing again, the same operation only activates drying. 2. When no one is seated, turn the knob clockwise to start manual cleaning function of the nozzle. 3. During rear and front washing, turn the knob clockwise to move the spray wand forward, and counterclockwise to move the spray wand backward; Long press the knob to switch to the water pressure adjustment function. Clockwise rotation increases the water pressure, while counterclockwise rotation decreases the water pressure. (Note: During washing, long press the knob to switch between the functions of water pressure adjustment and spray wand position adjustment. 4. During drying, clockwise rotation increases air temperature and counterclockwise rotation decreases air temperature. 5. In functional mode, press the knob to stop function in progress: rear washing, front washing, drying or nozzle cleaning. In addition, press the knob to flush the toilet. 6. To enter into standby mode (not seated), press and hold the knob. 7. To enter into functional mode, press and hold the knob. Note: Default settings for all functions are intermediate when powering on. Use remote control to switch to the function level set before. 09 LED display descriptionOnly for the toilet with LED display sterilization water temperature temperature display seat temperature ECO energy saving Description of LED display:
1. During self-inspection, icons of sterilization, water temperature, seat temperature and ECO light up, and the temperature is displayed at 88. After self-inspection, sterilization, water temperature and ECO icons go off and seat temperature icon lights up, showing current seat temperature. The temperature shows -- at neutral level. 2. In non-energy-saving mode, seat temperature icon lights up, showing current seat temperature (temperature in neutral shows "--"). During water temperature adjustment, seat temperature icon goes off and water temperature icon lights up, showing current water temperature (temperature in neutral shows "--"). Water temperature icon goes off and seat temperature is displayed after 10 seconds. 3. During washing, seat temperature icon goes off and water temperature lights up, showing current water temperature (temperature in neutral shows "--"). 4. Sterilization icon lights up when this function turned on, otherwise it goes off. 5. In energy saving mode, ECO icon lights up. Seat temperature in neutral shows "--", otherwise it shows Level 1. 6. LED display goes off completely when shutting down. 7. LED display goes off completely after 30 seconds once no longer being used. When seated or pressing any button, LED display is activated to show current status. 8. When user enters the sensing range, LED display lights up showing current status. Display goes off completely 30 seconds after user leaves. (Only for the toilet with lid auto open/close function.) 10 Troubleshooting guide Problem Cause Solution No water from nozzle Poor water spraying Low water temperature Low seat temperature Low dryer temperature Dryer not blowing Spray wand cannot retract Spray wand cannot stretch out Remote control cannot display Malfunction of deodorization Caution Water supply hose is kinked Straighten the hose to remove the kink Angle valve is off Turn on the angle valve A water failure occurred Restore the water supply Water supply hose is kinked Straighten the hose to remove the kink Angle valve is not fully turned on Filter is clogged The water temperature is not set properly The seat temperature is not set properly In standby mode The dryer temperature is not set properly In standby mode or energy saving mode Power off Turn on the angle valve fully Clean the filter Adjust the water temperature Adjust the seat temperature Switch to functional mode and wait for 3+ minutes Adjust the dryer temperature Switch to functional mode to use dry function Push back the spray wand gently and put power on Get stuck by impurities Remove the impurities Power off Turn on the power User is not within the sensing area of the seat The positive and negative direction of the batteries is incorrect Adjust position on seat to activate the sensor Reload the batteries Low battery Replace new batteries User is not within the sensing area of the seat Deodorization function continues after user leaves Adjust position on seat to activate the sensor It is normal for the deodorizing function to continue operating after user leaves, for complete odor removal. If the problem cannot be resolved as per above solutions, please disconnect the power and contact service providers. If the power leakage protection switch always trips, it means that the product is leaking. Please disconnect the power and contact service providers. 11 The picture of product may not be entirely consistent with actual appearance and color because of product improvements, please in kind prevail. ASVFA72320008A-1.1
1 | User Manual | Users Manual | 3.60 MiB | October 25 2022 / April 10 2023 | delayed release |
Model: V7282-3 / V7282-8 User Manual Thank you for choosing our products. Please read the instructions carefully before installation and keep it available for future maintenance or reference. Content S p e c i f i c a t i o n P a r a m e t e r e M a i n t e n a n c e O t h e r s Safety instructions Technical specification Parts identification Lid auto open/close Maintenance 1. Main unit care and maintenance 2. Spray nozzle care and maintenance 3. Filter maintenance Emergency troubleshooting 1. Power and water failure 2. Failure of remote control Description of the button function LED display description Only for the toilet with LED display Troubleshooting guide 01 03 05 06 07 08 09 10 11 SAFETY INSTRUCTIONS When using electrical products, especially when children are present, basic safety precautions should always be followed, including the following:
1. The appliance is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction. 2. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. 3. Children shall not play with the appliance. 4. Cleaning and user maintenance shall not be made by children without supervision. READ ALL INSTRUCTIONS BEFORE USING DANGERTo reduce the risk of electrocution:
1. Do not place or store product where it can fall or be pulled into a tub or sink. 2. Do not place in or drop into water or other liquid. 3. Do not reach for a product that has fallen into water. Unplug immediately. 4. Do not wash the main unit or electrical plug with water or detergent. 5. Do not handle the electrical plug with wet hands. 6. Never block the outlet of the air dryer. 7. Never disassemble, repair or modify this product. 8. During installation, disassembly, repair and maintenance of the product, the power plug must be switched off and water supply be shut off. WARNING To reduce the risk of burns, electrocution, fire, or injury to persons. 1. Close supervision is necessary when this product is used by, on, or near children or individuals with disabilities. 2. Use this product only for its intended use as described in this manual. Do not use attachments not recommended by the manufacturer. 3. Never operate this product if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water. Return the product to a service center for examination and repair. 4. Keep the cord away from heated surfaces. 5. Never use while sleeping or drowsy. 6. Never drop or insert any object into any opening or hose. 7. Do not use outdoors or operate where aerosol (spray) products are being used or where oxygen is being administered. 8. Connect this product to a properly grounded outlet only. See Grounding Instructions. 9. Do not throw cigarettes and other burning materials into toilet, otherwise it might cause fire. 10. This product is an electric appliance, so it must be placed far away from water and other liquid. 11. Do not lay the product on its side or upside down during the electrical circuit. 12. It is prohibited to use other electric appliances in the same socket. 13. It is forbidden to use the power extension or unstable loose outlet. 14. Do not reuse any existing water supply hoses, otherwise it might cause leakage, fire or electrical shock. Installation should include specified components and a new water supply hose. 01 IMPORTANT SAFETY INSTRUCTIONS CAUTION Failure to follow the instructions may cause bodily injury or property damage. 1. Do not install or use the product in wet places such as a steam room etc. 2. It is recommended to use water-proof electrical outlet which should be installed in a place where is not easily to get wet. 3. This product should be used with 110V-120V, 50/60Hz electrical current only, load current is at least 15A. Power plug must be equipped with ground fault circuit interrupter or ground fault electrical leakage protector or similar high sensitive, rapid type leakage switch. (Rated sensitive current under 6mA). 4. When it thunders, it is strongly recommended to pull out the power plug. 5. Do not stand on product unit, seat and lid. 6. Do not lean against the lid when using the product, to avoid damage. 7. This product is equipped with a soft-closing seat and lid. Do not push the toilet seat closed, or damage may occur. 8. Do not use any caustic chemicals or scrubbing brush to clean this product. 9. Exposure to direct sunlight is prohibited. 10. Only use tap water or potable water; otherwise it may cause chafing. 11. Do not connect water supply to a hot water supply. Make sure inlet water temperature is between 3~35/37.4~95. 12. Raise room temperature to prevent the toilet from damage due to freezing. 13. When not using the product over three(3) days, drain the water out of the toilet and pull the electrical plug from the wall outlet. 14. Stop using the product and shut off the power when product malfunctions. Call for professional service. 15. Means for full disconnection must be incorporated in series in the power input loop of the same room where the product is installed, that is at the front end of the fixed wiring to ensure safe use. GROUNDING INSTRUCTIONS This product should be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electrical current. The plug must be plugged into an outlet that is properly installed and grounded. DANGER Improper use of the grounding plug can result in a risk of electric shock. If repair or replacement of the cord or plug is necessary, do not connect the grounding wire to either flat-head terminal. Check with a qualified electrician or serviceman if the grounding wire instructions are not completely understood, or if in doubt as to whether the product is properly grounded. This product is factory equipped with a specific electric cord and plug to permit connection to a proper electric circuit. Make sure that the product is connected to an outlet having the same configuration as the plug. No adapter should be used with this product. Do not modify the plug provided if it will not fit the outlet, please have the proper outlet installed by a qualified electrician. If the product must be reconnected for use on a different type of electric circuit, the reconnection should be made by qualified service personnel. SAVE THESE INSTRUCTIONS 02 Technical specification Model Rated voltage Rated power Water proof Main Unit V7282-3 / V7282-8 110V-120V, 50/60Hz 905W IPX4 Water pressure range 0.08MPa - 0.8MPa (static pressure) Flush volume Flushing mode 1.6/1.1Gpf, 6.0L(full flush) /4.2L(half flush) Washdown Toilet Outlet height 212mm Outlet outside diameter 102mm Drainage method Heating power P-trap 1400W Water temperature 6-level adjustment (Neutral level included) Water volume 3-level adjustment Cleaning mode Rear washing /Oscillating washing, Front washing /Oscillating washing Cleaning device Nozzle position 5-level adjustment Water pressure protector Pressure maintaining device, Automatic pressure relief device Anti-fouling device Automatic nozzle cleaning, Anti-syphon device, Anti-backflow device, Filter device Safety device Thermal fuse, Water temperature sensor, Ground protection, Thermostat, Over temperature protection, Leakage protection device Warm air speed Over 4m/s Drying device Warm air temperature 6-level adjustment (Neutral level included) Heating power Safety device 200W Thermal fuse, Leakage protection device, Thermostat Deodorization
(optional) Sterilization
(optional) Deodorization method Photocatalyst-free Sterilization device Plasma sterilization Surface temperature 6-level adjustment (Neutral level included) Heating power 50W Heated seat Burn protection Safety device After 10 minutes of use, the seat temperature will automatically drop slowly to a low level Seat sensor, temperature sensor, thermal fuse, thermostat, leakage protection device 03 Night light assembly Intelligent, Always on, Always off Noise-free setting The buzzer is off at night for a quiet environment. User ID setting To avoid interference when used by multiple users Caring device Automatic flushing Toilet will automatically flush as user walks away from bowl. Foot sensor function
(optional) Activate lid opening (optional) Activate a half flush (optional) Difference description Lid opening
(optional) Soft close Lid auto-open Antibacterial site Seat, Nozzle Rated power:
Under the condition of ambient temperature 23/73, water static pressure 0.18MPa0.02MPa, water temperature 15/59, power toilet on, set water pressure, seat temperature, water temperature to the highest level in turn and perform one rear washing cycle. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. The remote control operates at 2.4 GHz frequency. The main unit performs corresponding function upon the signal from remote control. The lid auto open sensor module operates at 24 GHz frequency. The module will sense movement and open the lid when approached.(Only for the product with lid auto opening/
closing function) 04 Parts identification Left side Lid button Right side Drying shield Nozzle shield Spray nozzle Rear washing Front washing Bumper Seat Ceramic toilet Touch the sensing area with foot
(optional) Bumper Night light sensor 05 Lid auto open/close 1. Only for the product with lid auto opening/closing function. This function is turned off by default. For the first use, please turn on this function by remote control. 1. Approaching the toilet When user enters the sensing range, the ECO lights up and the lid opens automatically. 2. Leaving the toilet The lid closes automatically 180 seconds after user leaves. 2. If the model you purchased is with foot sensor, 1. When the seat and lid are both closed, touch the sensing area with your foot to open the lid. 2. When the lid is open and seat is closed, touch the sensing area with your foot to close the lid and activate a half flush. 3. When the seat and lid are open, touch the sensing area with your foot to activate a half flush. 06 Maintenance Main unit care and maintenance 1. Shut off power supply before doing maintenance. 2. Use only a soft, damp cloth to clean. Avoid using harsh chemicals. Spray nozzle care and maintenance 1. When no one is seated, turn the knob clockwise. The nozzle will automatically stretch out to allow access for cleaning. 2. When the nozzle moves forward, the nozzle can be removed and cleaned separately. 3. Use only a soft cloth or soft brush to clean. Do not pull or push the wand, to avoid damage. 3. Once cleaning is completed and all surfaces are dry, re-connect the power plug. 4. Put the nozzle back and press the knob to return the spray wand to its normal position. Note:
The spray wand will retract automatically after 10 minutes or if the seat is used. 07 Emergency troubleshooting Filter maintenance If poor spray performance occurs under normal conditions:
1. Turn off power and ball valve, unscrew water supply hose. Power and water failure Put around 8L water into a barrel and flush the ceramic bowl. Note: Avoid water spilling from bowl. Failure of remote control 1. Operate via knob on the main unit. Connect the end of the bidet 2. Remove the filter. 3. Clean out filter under running water. 4. Reinstall filter and water supply hose, turn on ball valve and connect power. 2. Battery replacement Remove the remote control from holder. Open the battery cover and replace the batteries. Put the remote control back. Note:
After battery replacement, the settings of auto functions and energy saving will be restored to the defaults. Please reset. 08 Description of the button function Stop 1. Press and hold Stop button to enter shutdown mode (white light off), press Stop button again to return to functional mode (white light always on). In shutdown mode, all functions and buttons (with the exception of the Stop Button) will not operate. 2. When seated, short press Stop Button to stop front washing, rear washing or drying functions. When no one is seated, repeatedly press Stop button, the main unit will switch between functional mode (white light always on) and energy saving mode (white light flashing). Rear washing/
Oscillating washing 1. When seated, press Rear washing button to start rear washing function and press again to shift to oscillating washing. Press Stop button to stop rear washing immediately. After one cycle washing, drying function will be automatically turned on and stop after one cycle. 2. When no one is seated, press Rear washing button, the nozzle will stretch out to allow access for cleaning; Press Stop Button, the nozzle will retract. Front washing/
Oscillating washing When seated, press Front washing button to start front washing function and press again to shift to oscillating washing. Press Stop button to stop front washing immediately. After one cycle washing, drying function will be automatically turned on and stop after one cycle. 1. When seated, long press Flushing Button to start drying function. The drying will stop automatically after on cycle, while it will stop immediately if the user presses Stop button. 2. In non-off mode, short press Flushing button to start flushing function. During rear washing or front washing, flushing function will not operate. During nozzle cleaning, only when spray wand is fully extended or retracted can flushing function be activated. Flushing Note: Default settings for all functions are intermediate when powering on. Use remote control to switch to the function level set before. 09 LED display descriptionOnly for the toilet with LED display sterilization water temperature temperature display seat temperature ECO energy saving Description of LED display:
1. During self-inspection, icons of sterilization, water temperature, seat temperature and ECO light up, and the temperature is displayed at 88. After self-inspection, sterilization, water temperature and ECO icons go off and seat temperature icon lights up, showing current seat temperature. The temperature shows -- at neutral level. 2. In non-energy-saving mode, seat temperature icon lights up, showing current seat temperature (temperature in neutral shows "--"). During water temperature adjustment, seat temperature icon goes off and water temperature icon lights up, showing current water temperature (temperature in neutral shows "--"). Water temperature icon goes off and seat temperature is displayed after 10 seconds. 3. During washing, seat temperature icon goes off and water temperature lights up, showing current water temperature (temperature in neutral shows "--"). 4. Sterilization icon lights up when this function turned on, otherwise it goes off. 5. In energy saving mode, ECO icon lights up. Seat temperature in neutral shows "--", otherwise it shows Level 1. 6. LED display goes off completely when shutting down. 7. LED display goes off completely after 30 seconds once no longer being used. When seated or pressing any button, LED display is activated to show current status. 8. When user enters the sensing range, LED display lights up showing current status. Display goes off completely 30 seconds after user leaves. (Only for the toilet with lid auto open/close function.) 10 Troubleshooting guide Problem Cause Solution No water from nozzle Poor water spraying Low water temperature Low seat temperature Low dryer temperature Dryer not blowing Spray wand cannot retract Spray wand cannot stretch out Remote control cannot display Malfunction of deodorization Caution Water supply hose is kinked Straighten the hose to remove the kink Angle valve is off Turn on the angle valve A water failure occurred Restore the water supply Water supply hose is kinked Straighten the hose to remove the kink Angle valve is not fully turned on Filter is clogged The water temperature is not set properly The seat temperature is not set properly In standby mode The dryer temperature is not set properly In standby mode or energy saving mode Power off Turn on the angle valve fully Clean the filter Adjust the water temperature Adjust the seat temperature Switch to functional mode and wait for 3+ minutes Adjust the dryer temperature Switch to functional mode to use dry function Push back the spray wand gently and put power on Get stuck by impurities Remove the impurities Power off Turn on the power User is not within the sensing area of the seat The positive and negative direction of the batteries is incorrect Adjust position on seat to activate the sensor Reload the batteries Low battery Replace new batteries User is not within the sensing area of the seat Deodorization function continues after user leaves Adjust position on seat to activate the sensor It is normal for the deodorizing function to continue operating after user leaves, for complete odor removal. If the problem cannot be resolved as per above solutions, please disconnect the power and contact service providers. If the power leakage protection switch always trips, it means that the product is leaking. Please disconnect the power and contact service providers. 11 The picture of product may not be entirely consistent with actual appearance and color because of product improvements, please in kind prevail. ASVFA7282000*A-1.0
1 | External Photos | External Photos | 838.72 KiB | October 25 2022 / April 10 2023 | delayed release |
1 | ID Label and Location | ID Label/Location Info | 473.41 KiB | October 25 2022 / November 01 2022 |
1 | Agency Letter | Cover Letter(s) | 84.97 KiB | October 25 2022 / November 01 2022 |
Number: MS-0045317 .
/. TUVRheinland TCB Authority to Act as Agent Revision: 0 Effective date: Oct 8, 2021
, Authority to Act as Agent Date: 11 July, 2022 TUV Rheinland of North America, Inc. 1279 Quarry Lane., Suite. A Pleasanton, CA 94566 To Whom It May Concern:
| appoint TUV_ Rheinland (Shenzhen) Co., Ltd. to act as our agent in the preparation of this application for equipment certification. | certify that submitted documents properly describe the device or system for which equipment certification is sought. | also certify that each unit manufactured, imported or marketed, as defined in the FCC or Industry Canadas regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, |
acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by TUV Rheinland Group, still resides with Xiamen R&T Plumbing Technology Co., Ltd. /
No.18, HouXiang Road, HaiCang District, Xiamen, 361028, China For TCB applications, We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you, Agency Agreement Date: 12 Months Agreement is valid for 12 months from the above date. By:
Honqwei Wang
(Signature) { (Print name) Manager +8605926539772
(Title) (Telephone) On behalf of:
Xiamen R&T Plumbing Technology Co., Ltd.
(Company Name) Page 1 of 1
1 | Confidentiality Letter | Cover Letter(s) | 101.84 KiB | October 25 2022 / November 01 2022 |
Standard Form Request for Confidentiality Letter rOvAheinland Koa SHA AIDA Date: 11 July, 2022 Subject: Confidentiality Request for FCC ID: 2AW23-V7232V7282 Pursuant to FCC 47 CRF 0.457(d) and 0.459, the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality Requested
[x] Permanent Block Diagrams ternal Photos
><} Permanent peration Description/Theory of Operation une-Up Procedure chematics sers Manual est Setup xternal Photos ge) oO len}
3 pa)
=) ao jn) o
=) Xiamen R&T Plumbing Technology Co., Ltd. has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: , The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality:
The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of 180 __ days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify TUV Rheinland in the event information regarding the product or the product is made available to the public. TUV Rheinland will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. Sincerely, By: Hongwei Wang / Manager
(Signature/Title) (Print name) MS-0044715 Page 1 of 1 Revision 0
1 | Test Setup Photos | Test Setup Photos | 1.12 MiB | October 25 2022 / April 10 2023 | delayed release |
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2022-11-01 | 24025 ~ 24250 | DXX - Part 15 Low Power Communication Device Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2022-11-01
|
||||
1 | Applicant's complete, legal business name |
Xiamen R&T Plumbing Technology Co.,LTD.
|
||||
1 | FCC Registration Number (FRN) |
0029737574
|
||||
1 | Physical Address |
No.18, HouXiang Road, HaiCang District,Xiamen
|
||||
1 |
Fujian, N/A
|
|||||
1 |
China
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
t******@tuv.com
|
||||
1 | TCB Scope |
A2: Low Power Transmitters (except Spread Spectrum) and radar detectors operating above 1 GHz
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
2AW23
|
||||
1 | Equipment Product Code |
V7232V7282
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
H******** W******
|
||||
1 | Telephone Number |
+8605********
|
||||
1 | Fax Number |
+8605********
|
||||
1 |
e******@esmart-toilet.com
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
Xiamen R&T Plumbing Technology Co.,LTD.
|
||||
1 | Physical Address |
No.18, HouXiang Road, HaiCang District,Xiamen
|
||||
1 |
Fujian
|
|||||
1 |
China
|
|||||
1 | Telephone Number |
+8605********
|
||||
1 |
e******@esmart-toilet.com
|
|||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | If so, specify the short-term confidentiality release date (MM/DD/YYYY format) | 04/10/2023 | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DXX - Part 15 Low Power Communication Device Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Intelligent Toilet | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
MRT Technology (Suzhou) Co., Ltd.
|
||||
1 | Name |
M**** C********
|
||||
1 | Telephone Number |
+86-5******** Extension:
|
||||
1 |
m******@mrt-cert.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 24025.00000000 | 24250.00000000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC