WDZ3ZT92
ZETA Water Leak Sensor
1
WDZ3ZT92
Copyright Statement
ZiFiSense owns the copyright on this specification. No part of
this specification may be reproduced in any form or means,
without the prior written consent of ZiFiSense.
Disclaimer
This specification is preliminary and is subject to change at any
time without prior notice. ZiFiSense assumes no responsibility
for any errors contained herein. ZiFiSense is not responsible for
any patent infringement of third party on its use or as a result
of its uses. Other products/services not certified by the patent
license, shall be deemed within patent ownership of ZiFiSense.
2
WDZ3ZT92
Table of Contents
1. Product Description.........................................................................................................................4
2. Applications....................................................................................................................................... 4
3. Appearance........................................................................................................................................ 4
4. Features.............................................................................................................................................. 4
5. Product parameters......................................................................................................................... 5
6. Packing List........................................................................................................................................5
7. Installation.......................................................................................................................................... 6
7.1. Screw...................................................................................................................................... 6
7.2. Adhesive 3M.......................................................................................................................... 8
7.3. Cable Ties.............................................................................................................................. 9
8. Use of Device................................................................................................................................... 12
8.1. Power on...............................................................................................................................12
8.2. Support function.................................................................................................................. 12
9. Common faults and handling...................................................................................................... 12
3
1. Product Description
WDZ3ZT92
ZETA Water Leak Sensor is a low power dry contact sensor which uses
electrodes to detect the leak water and generate dry contact signal, report
immediately once it detects the leak water.
2. Applications
Water leak detection, such as elevator pit water alarm, water collection
overflow of air conditioner, overflow of sewage wells
3. Features
Wireless transmission
Battery-powered, low power consumption
Easy to install, high sensitivity
Reliable detection
Real-time transmission
4
WDZ3ZT92
4. Product parameters
/ WDZ1ZT92/ WDZ2ZT92
Product No.
WDZ3ZT92
Transmission protocol
ZETA
Wireless Features
Frequency band
Output power
Sub-GHz, adjustable according to
local regulations
20dBm max, adjustable according
to local regulations
Electrical Features
Power supply
Battery, 2*ER14505
Battery capacity
2*2700 mAh
Stand-by current
≤ 10 μA
Working current
≤ 70 mA
Size
66*55*36 mm
Sense cable
Customisable cable length
Physical Features
Enclosure material
Waterproof level
ABS
IP30
Antenna
Monopole antenna
℃
℃
Working
Environment
Operating temperature
℃
-20
~+60
℃
Storage temperature
-30
~+85
5. Packing List
Motion Sensor
Probe sensor /Sense cable
Battery (ER14505)
1
1
2
5
6. Installation
WDZ3ZT92
There are three installation methods: Screw, 3M Adhesive and cable ties.
6.1. Screw
6.1.1.Auxiliary material
No. Materials
1
2
self tapping screw (M3*20)
#4 expanded plastic pipe
,
,
3
4
Percussion drill
#4 drill bit
hammer
slotted screwdriver, cross screwdriver
6.1.2.Installation instructions
Use a slotted screwdriver to open the top cover from the bottom edge.
Open the device case
Quantity
2/device
2
1
1
opening
Place the device in the mounting position, punch and insert the expanded
plastic pipe.
Punching
Fixation
6
WDZ3ZT92
Use the self-tapping screws to secure the device in the mounting position.
mounting hole
mounting hole
Power on
Insert the power plug into the upper power socket, install two 14505
batteries (remove the insulation sheet for the existing battery), and close
the upper cover.
power socket
7
6.2. Adhesive 3M
6.2.1.Auxiliary material
WDZ3ZT92
No. Materials
Quantity
3M seamless thickened double-sided adhesive
5CM
Slotted screwdriver, utility knife
2
1
2
6.2.2.Installation instructions
Installation position
Select a flat mounting position, and clean it up.
Open the device case
Use a slotted screwdriver to open the top cover from the bottom edge.
opening
Power on
Insert the power plug into the upper power socket, install two 14505
batteries (remove the insulation sheet for the existing battery), and close
the upper cover.
8
WDZ3ZT92
power socket
Adhesive device
Take the appropriate amount of 3M adhesive, attach it to the back of the
sensor, remove the protective film of the 3M adhesive, and install the
device to the specified position.
6.3. Cable Ties
6.3.1.Auxiliary material
No. Materials
(
1
2
Metal cable ties
5*300mm)
Slotted screwdriver, utility knife
6.3.2.Installation instructions
Quantity
2
Open the device case
Use a slotted screwdriver to open the top cover from the bottom edge.
9
WDZ3ZT92
opening
Fixation
Pass the 2 cable ties through the device and secure to the installation rod
Installation position
10
WDZ3ZT92
Power on
Insert the power plug into the upper power socket, install two 14505
batteries (remove the insulation sheet for the existing battery), and close
the upper cover.
power socket
11
6.4. Installation of sense cable
WDZ3ZT92
If it is the model of WDZ3ZT, it is necessary to standardize the installation
6.4.1.Auxiliary material
of the sense cable.
Material
Wire nail
Hammer
Screwdriver
No.
few
1
1
6.4.2.installation steps
Note:
Plan the installation and routing position of the sense cable before
installation.
The two ends of the sense cable have their own interface plugs, and the
plugs can be connected with the plugs connected to the sensors.
The part of the sense cable is fixedly installed according to the planned
line, and it is neat and tidy.
Any one of the sense cable will trigger an alarm.
The two black wires of the cable are conductive adhesives. If the
resistance between the black wires is less than 50MΩ, the alarm will be
triggered regardless of whether the wire is stripped.
During the installation or post-maintenance process, if you need to
re-wire the wiring.
Avoid the two black wires to be contact too close.
12
WDZ3ZT92
7. Use of Device
7.1. Power on
Place the device within the coverage of the ZETA network, install the
battery, and wait for the device to go online. After the device is online, the
current sensor status is reported once.
13
7.2. Support function
WDZ3ZT92
Report/Query version number: After the power is turned on, the
version number information is reported by default. After that, the
query can be sent.
Status report: Reports the heartbeat/alarm/de-alarm status, and
reports a heartbeat status after power-on.
Set/Query the alarm report period: The time when the sensor detects
the periodic report when it is flooded (range: 0-255 minutes, default
value: 0, 0 means the alarm is only reported once, no periodic report is
required.)
Set/Query Report Heartbeat Period: You can set or query the currently
set heartbeat reporting period by minute. (Range: 1~65535 min,
default: 24*60 min)
Set/Query Alarm Enable: Enable ON means that the alarm status needs
to be reported when the threshold is exceeded. Enable Off means no
alarm is required even if the threshold is exceeded.
Set/Query Acquisition Period: The period during which the device
collects sensor information (range: 0-65535 seconds, when the value is
0, it means real-time acquisition, default value: 5s).
Query device status: Actively query the current status of the device,
including whether it is flooded, and alarm enable information.
8. Common faults and handling
Ensure ZETA signal coverage
Ensure that the device is powered on, and the ZETA network device
management platform can observe that the ZETA module is on line
Check the battery usage of the device. When the battery is low, replace
the battery in time.
14
FCC WARNING
Any Changes expressly or modifications not approved by the party responsible for compliance
could void the user's authority to operate the equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference,
and (2) this device must accept any interference received, including interference that may cause
undesired operation.