YFGW520 Field Wireless Access Point Read Me First IM 01W02E02-11EN This document specifies the important information to use this product correctly and safely and the License Agreement of Attached Software for YFGW520 Field Wireless Ac-
cess Point. Before use the product, be sure to read this document first. The configuration of the field wireless system is described in Users Manual of the YFGW410 Field Wireless Management Station (IM 01W02D01-01EN). Read that document first. Contents Introduction ...................................................................................................2 Safety Precautions .......................................................................................4 Explosion Protected Type Specifications .............................................. 12 Installation of an Explosion Protected Instrument ......................... 13 ATEX ...................................................................................................... 14 IECEx ..................................................................................................... 21 Ground Cable Connection .................................................................. 29 How to Use Online Manual ....................................................................... 30 Preparation to Use YFGW520 Attached Software ................................. 30 Copyright and Trademark Notices .......................................................... 31 Patent Notice ............................................................................................. 31 Open Source Software ............................................................................. 32 About Users Manual ................................................................................ 32 Information of Users Manual Revision .................................................. 33 YFGW520 Software License Agreement ................................................. 34 IM 01W02E02-11EN 1st Edition UsersManual 2 Introduction This manual (IM 01W02E02-11EN) describes the safety precautions, explosion protected type specifications and the license agreement of attached software for the YFGW520. There are three documents including this one for the YFGW520 listed below. Read them along with this manual. Document No. IM 01W02E02-01EN IM 01W02E02-11EN Document name YFGW520 Field Wireless Access Point YFGW520 Field Wireless Access Point Read Me First GS 01W02E02-01EN YFGW520 Field Wireless Access Point Description This manual is stored in the attached DVD-ROM for YFGW520. It describes installation, wiring, operation, maintenance and specification of the YFGW520. This manual. It describes the safety precaution, explosion protected type specifications and the license agreement of the attached software for the YFGW520. Product specification including detailed model and suffix code, optional specifications and accessory of the YFGW520. n Regarding This User's Manual l This manual should be provided to the end user. Please recommend end users to keep this manual at hand and refer to it as needed. l This manual and the identification tag attached on packing box are essential parts of the product; keep them in a safe place for future reference. l Before use, read this manual thoroughly to comprehend its contents. l The purpose of the Users Manual is to describe details of functions provided in this product, not to warrant the product's suitability to the specific purposes of customers. l No part of this manual may be reproduced in any form without Yokogawa's written permission. l The contents of this manual may be changed without prior notice. l All reasonable effort has been made to ensure the accuracy of the contents of this manual. However, if any errors or omissions are found, please inform any of sales offices listed on the back cover or your local distributor. l The specifications covered by this manual are limited to those for the standard type under the specified model number break-down and do not cover custom-
made instruments. When products whose suffix code or optional codes contain code Z and an exclusive document is attached, please read it along with this manual. l Please note that this Users Manual may not be revised for any specification changes, construction changes or operating part changes that are not considered to affect function or performance.
<Read Me First>IM 01W02E02-11EN n ATEX Documentation l This is only applicable to the countries in European Union. GB DK I E NL SF P F D S GR SK CZ LT LV EST PL SLO H BG RO M 3 F01.ai
<Read Me First>IM 01W02E02-11EN Safety Precautions n Safety, Protection, and Modification of the Product 4 l In order to protect the operator, product, and system controlled by the product, observe the safety precautions described in this Users Manual. If users handle contrary to these instructions, we can not guarantee the safety. l If this instrument is used in a manner not specified in this Users Manual, the protection provided by this instrument may be impaired. l Modification of the product is strictly prohibited. l If customers attempt to repair or modify explosion protected type products and fail to return them to their original state, the explosion protected structure of this product will be lost, resulting in a hazardous state. All repairs and modifications of the product must be consulted with Yokogawa. l If any protection or safety circuit is required for the system controlled by the product or for the product itself, prepares it separately. l Be sure to use the spare parts approved by Yokogawa Electric Corporation
(hereafter simply referred to as Yokogawa) when replacing parts or consumables. l The following symbols are used in the product and Users Manual to indicate that there are precautions for safety:
CAUTION Indicates that caution is required for operation. This symbol is placed on the parts necessary to refer to the Users Manual for protecting the operator and equipment. In the Users Manual you will find precautions to avoid physical injury or death of the operator, including electrical shocks, injuries of human body, and so on. WARNING Indicates instructions that must be observed in order to prevent the software or hardware from being damaged or the system from becoming faulty. IMPORTANT Indicates important information required to understand operations or functions.
<Read Me First>IM 01W02E02-11EN NOTE Draws attention to information essential for understanding the operation and features. 5 TIP Indicates additional information. SEE ALSO Indicates a source to refer to Indicates a protective grounding terminal. Before using the product, ground the terminal. Indicates a functional grounding terminal. Before using the product, ground the terminal. Indicates a DC supply n Safe Use of This Product This product is designed to be used by a person with specialized knowledge. For the safety of the operator and to protect the instrument and the system, please be sure to follow this manuals safety instructions when handling this instrument. If these instructions are not heeded, the protection provided by this instrument may be impaired. In this case, Yokogawa cannot guarantee that the instrument can be safely operated. Please pay special attention to the following points:
(a) Installation This instrument may only be installed by an engineer or technician who has an expert knowledge of this device. Operators are not allowed to carry out installation unless they meet this condition. All installation shall comply with local installation requirements and the local electrical code.
(b) Wiring The instrument must be installed by an engineer or technician who has an expert knowledge of this instrument. Operators are not permitted to carry out wiring unless they meet this condition.
(c) Operation Wait 1 min. after the power is turned off, before opening the covers.
(d) Maintenance Please carry out only the maintenance procedures described in this manual. If you require further assistance, please contact the nearest Yokogawa office. Care should be taken to prevent the build up of dust or other materials on the display glass and the name plate. To clean these surfaces, use a soft, dry cloth.
(e) Explosion Protected Type Instrument Users of explosion protected instruments should refer first to Explosion Protected Type Specifications section of this manual. The use of this instrument is restricted to those who have received appropriate training in the device.
<Read Me First>IM 01W02E02-11EN 6 Take care not to create sparks when accessing the instrument or peripheral devices in a hazardous location. Repair or modification to this instrument by customer will cause malfunction of explosion protect function and hazardous situation. If you need to repair or modification, please contact the nearest Yokogawa office.
(f) Modification Yokogawa will not be liable for malfunctions or damage resulting from any modificationmade to this instrument by the customer.
(g) Product Disposal The instrument should be disposed of in accordance with local and national legislation/
regulations. n Warranty l The warranty terms of this instrument are described in the quotation. We will make any repairs that may become necessary during the guaranteed term free of charge. l Please contact our sales office or your local distributor if this instrument requires repair. l If the instrument is faulty, contact us with complete details about the problem and the length of time it has been faulty, and state the model and serial number. We would appreciate the inclusion of drawings or additional information. l The results of our examination will determine whether the product will be repaired free of charge or on an at-cost basis. n The guarantee will not apply in the following cases:
l Damage due to negligence or insufficient maintenance on the part of the customer. l Problems or damage resulting from handling, operation or storage that violates the intended use and specifications. l Problems that result from using or performing maintenance on the instrument in a location that does not comply with the installation location specified by Yokogawa. l Problems or damage resulting from repairs or modifications not performed by Yokogawa or someone authorized by Yokogawa. l Problems or damage resulting from inappropriate installation after delivery.
<Read Me First>IM 01W02E02-11EN l Problems or damage resulting from disasters such as fires, earthquakes, storms, floods, or lightning strikes and external causes. 7 n Warranty and Disclaimer l Yokogawa assumes no responsibilities for this product except as stated in the warranty. l Yokogawa shall have neither liability nor responsibility to any person or entity with respect to any direct or indirect loss or damage arising from using the product or any defect of the product that Yokogawa can not predict in advance. n Authorized Representative in the EEA The Authorized Representative for this product in the EEA is: Yokogawa Europe B.V. Euroweg 2, 3825 HD Amersfoort, THE NETHERLANDS. n Notes on Hardware l Appearance and Accessories Check the following when you receive the product:
Appearance Standard accessories Contact our sales representative or your local distributor if the products coating has come off or any accessories are missing. l Model and Suffix Codes The name plate on the product contains the model and suffix codes. Verify that the specification indicated in the MODEL AND SUFFIX CODES and OPTIONAL SPECIFICATIONS in General Specifications GS 01W02E02-01EN is in compliance with the specifications written on the order sheet. If you have any questions, contact our sales office or your local distributor. n Notes on Attached Software l Before opening the media package, read YFGW520 Software License Agreement. Once the package is opened, it is thought that the contract is agreed. l Yokogawa assumes no responsibilities for this software except as stated in the warranty. l This software is used with this product exclusively. This can be installed in the computer which connects with this product.
<Read Me First>IM 01W02E02-11EN n Regulatory Compliance for Radio and Telecommunication Please confirm that an installation region fulfills a standards, require additional regulatory information and approvals, contact to Yokogawa Electric Corporation. 8 l Radio Equipment Directive Hereby, Yokogawa Electric Corporation declares that the radio equipment type YFGW520 is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address:
http://www.yokogawa.com/fld/
l EMC Conformity Standards EN 301 489-1, EN 301 489-17, EN 61326-1 Class A, Table 2 (For use in industrial locations), EN55011 Class A, Group 1, EN61000-6-2 This instrument is a Class A product, and it is designed for use in the industrial environment. Please use this instrument in the industrial environment only. l Safety Conformity Standards Applicable standard: EN61010-1, EN62479
(1) Pollution Degree 2 Pollution degree describes the degree to which a solid, liquid, or gas which deteriorates dielectric strength or surface resistivity is adhering. 2 applies to normal indoor atmosphere. Normally, only non-conductive pollution occurs. Occasionally, however, temporary conductivity caused by condensation must be expected.
(2) Installation Category I Overvoltage category (Installation category) describes a number which defines a transient overvoltage condition. It implies the regulation for impulse withstand voltage. I applies to electrical equipment which is supplied from the circuit when appropriate transient overvoltage control means (interface) are provided. l Spectrum Conformity Standard EN 300 328
<Read Me First>IM 01W02E02-11EN l FCC compliance 9 FCC Approval (Part 15C) This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Co-located:
This transmitter must not be co-located or operated in conjunction with any other antenna or transmitter. FCC CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. NOTE This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. RF Exposure Compliance:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment and meets the FCC radio frequency (RF) Exposure Guidelines. This equipment should be installed and operated keeping the radiator at least 20cm or more away from persons body.
<Read Me First>IM 01W02E02-11EN l ISED compliance
<Read Me First>
10 This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numrique de la classe A est conforme la norme NMB-003 du Canada. This device complies with ISEDs applicable licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR dISDE applicables aux appareils radio exempts de licence.Lexploitation est autorise aux deux conditions suivantes : (1) lappareil ne doit pas produire de brouillage, et (2) lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. This radio transmitter IC Number 8999A-WIC014 has been approved by ISED to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Antenna type Frequency Band Gain, Impedance Description Sleeve Collinear Hybrid patch 2.4 GHz 2.4 GHz 2.4 GHz 2.14dBi, 50 9dBi, 50 15dBi, 50 Le prsent metteur radio IC Number 8999A-WIC014 a t approuv par Industrie Canada pour fonctionner avec les types dantenne numrs ci-dessous et ayant un gain admissible maximal et limpdance requise pour chaque type dantenne. Les types dantenne non inclus dans cette liste, ou dont le gain est suprieur au gain maximal indiqu, sont strictement interdits pour lexploitation de lmetteur. Antenna type Frequency Band Gain, Impedance Description Sleeve Collinear Hybrid patch 2.4 GHz 2.4 GHz 2.4 GHz 2.14dBi, 50 9dBi, 50 15dBi, 50 This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment and meets RSS-102 of the IC radio frequency (RF) Exposure rules. This equipment should be installed and operated keeping the radiator at least 20cm or more away from persons body. Cet equipement est conforme aux limites dexposition aux rayonnements enoncees pour un environnement non controle et respecte les regles dexposition aux frequences radioelectriques
(RF) CNR-102 de lIC. Cet equipement doit etre installe et utilise en gardant une distance de 20 cm ou plus entre le radiateur et le corps humain. IM 01W02E02-11EN 11 n Control of Pollution Caused by the Product l EU RoHS This product is in conformity with the following standard:
EN 50581:2012 (Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances)
<Read Me First>IM 01W02E02-11EN