Workers Approach Warning System User's Manual Yoshikawa Kogyo Co., Ltd. 1. About this system Be sure to read this section before use. This system can provide only warnings to drivers and workers, and the braking operations such as braking of vehicles must be performed by the driver. It is impossible for this system only to prevent all accident. You must confirm the safety by sight as before. Consult with us if you have a heart pacemaker or a medical device such as a life support device installed. Radio wave interference in the surrounding area may cause the range of radio waves to change. We recommend measuring the radio wave environment in advance in the vicinity of electronic devices, power supply panels, cranes, and other heavy equipment. The detection range varies depending on the installation environment and surrounding conditions. After installation, confirm that the unit is operating correctly by following the operation check procedure. Confirm proper operation according to the daily inspection procedure in the User's Manual. Use in extremely high or low temperatures may cause malfunction or failure. Use within the operating temperature. Due to legal restrictions, this product is prohibited from being used for applications other than those related to Safety operation of the vehicle. It is illegal to disassemble or modify TAGs. Specifications and appearance are subject to change without notice for improvement. Line-up 1 3 4 5 6 No. Model Name Model number Power supply voltage Detection range Note DETECTOR YS-F-R023A DC 48V 38m Power supply cable 5m included
(stripped on one side) Up to 87dB, IP54 Speaker YS-F-S003A Indicator lamp YS-F-V027A-R No. Model Name Model number Alarm function Batteries Note ALERT-TAG YS-F-T003A Vib & Buzzer AAA 2pcs In the pocket or waistbelts STANDARD-TAG YS-F-T008A None CR2032 Attached on the helmet. 2. Glossary Term Meaning Detector It has a transmit function by a magnetic field, and an alarm function by receiving a radio signal from a TAG. It has a function to receive the magnetic field from the detector and a function to transmit radio waves. TAG Magnetic field Radio waves ALERT-TAG has a function to alert you. The magnetic field transmitted by the detector uses the 125kHz band. Stable sensing distance is achieved by using a magnetic field. The radio waves transmitted by the TAG use the 315MHz band. Transmitting radio waves from the TAG to the detector enables the detector to alert. They are used to define levels of sealing effectiveness of electrical enclosures against intrusion from foreign bodies (tools, dirt etc.) and moisture. As defined by International Standard EN 60529. 7 IP65 IP6 * [0 to 6] Dust-proof 6: Dust does not enter the inside. IP*5 [0 to 8] Waterproof 5: low-pressure jets (6.3 mm) of directed water from any angle Noise that affects the radio waves received by the detector. In places where radio noise is present, the sensing distance that the detector alarms may be shortened. Noise affecting the magnetic field received by the TAG. In places where magnetic field noise is present, the detection distance of the TAG may be shortened. Radio wave noise Magnetic field noise Ex. 1 2 3 4 10 11 the power distribution boards, factory equipment and large motors. Indicates the unit of sound volume. 12 dB Ex. 90dB: Bulldozer, etc. in a noisy plant 110dB: Automobile horn, etc. 3. What is Worker Approach Warning System?
This is a system that alerts people and vehicles to "dangerous situations" , when they are in close proximity with the technology of magnetic fields and electromagnetic waves. 1. A magnetic field (125KHz) is being transmitted from the detector. The direction of the magnetic field is transmitted in all directions by 360, and the transmission range is an oval shape with the largest longitudinal direction. 2. Radio waves (315MHz) including "Detection signal" and "Magnetic field strength"
are transmitted from the TAG in the area where the magnetic field from the detector reaches (max. 8m). 3. The detector sounds an alarm by determining the distance based on the magnetic field strength from the TAG. If you use ALERT-TAG, you can also alert from a TAG. Notes Detection range The detection area is 360 degrees in an oval. The oval shape depends on the orientation of the detector. Depending on the vehicle shape and environment, the detection area may not be an oval. Maximum detection range (e.g., 8m version outside detection range) Long side direction of the detector case:
Set distance Short side direction of the detector case:
Approx. 80% of the set distance
0 8
. x o r p p A DETECTOR Detection Range Distance Attenuation in the Environmental conditions The sensing distance may be slightly reduced depending on the environmental conditions
(effects of magnetic field noise or radio wave noise, structure of the building including reinforcement, etc.). e.g. 8m In this case, the setting of the detection distance by dialing decreases proportionally. may be reduced to 6m. DETECTOR (YS-F-R023A) Power Indicator Select alert sound FUSE POWER ALERM RANGE Select Range Vent filter Fuse Vent filter Do not touch it , because it is necessary to maintain the waterproof property. Fuse Use a mini glass tube fuse 5mm 2A. Power Indicator Green lights up when the detector is turned on. Select RANGE switch The maximum detection range can be set. Select ALERM switch Change the alert sound . Antenna Indicator lamp connector Speaker connector Power connector ANT LAMP SPEAKER POWER Antenna The radio signal receiving antenna is connected. Power connector (red) Connect the power cable (red). Speaker connector (green) Connects the speaker (green). Indicator Lamp connector (Blue) Connect the Indicator lamp (yellow) If the indicator lamp is not used, be sure to attach a protective cap to prevent dust into the unit. STANDARD-TAG (YS-F-T008A) The operator carries it. Alert function: None (The TAG itself does not alert) Wearing the watch: Mounting the helmet or storing it in a pocket Dust-proof/waterproof type : IP65 Low Battery LED Lights up (red) when the battery level is low. Battery 000126 YOSHIKAWA KOGYO YS-F-T008A FCC ID:2AWRK-YS-KT008 Mounting plate ALERT-TAG (YS-F-T003A) The operator carries it. Alarm Function: Required (Vibration, Sound, Light) Mobile method: Pocket and waistbelts Low Battery LED Lights up (red) when the battery level is low. Detection LED Flashes (red) when the detector enters the magnetic field detection range. Buzzer An alarm sounds when the TAG enters the magnetic field detection area of the Detector. Vibration It vibrates when it enters the magnetic field detection range of the detector. ALARM OFF BUTTON Used to stop the alarm. And check the battery. Battery ALERT YS-F-T003A YOSHIKAWA KOGYO FCC ID: 2AWRK-YS-KT008 AREA Action Near the vehicle Stop the alert Far from vehcle Low Battery LED Blink Enough OFF Empty 4. Alarm action Alarm function When the operator enters the detection range of the vehicle, the speaker (or indicator lamp) connected to the detector alarms. If a tag with an alarm function is used, an alarm will be sent from the tag at the same time. The alarm goes out of the detection range and stops after about 2 seconds. For Tags with Alarm Function ~
Speaker Alert both drivers and workers alert Operator Vibration Detector ALERT-TAG Detection range alert Blinking For Tags without Alarm Function ~
Speakers Alert drivers Operator alert Detector STANDERD
-TAG 5. Specification DETECTOR Model number Supply Voltage power consumption Operating Temperature Detection Range Transmission frequency Receive frequency Dustproof and water resistant Dimension Speaker Model number Supply Voltage power consumption Maximum Volume Dustproof and water resistant Weight Dimension Model number Supply Voltage power consumption Lighting Mode Dustproof and water resistant Dimension Indicator lamp W150D200H76mm YS-F-R023A DC48V 48W
-10+60 8m 125KHz 315MHz IP65 YS-F-S003A DC12-24V 3.5W 87dB IP54 300g DC9V 2.8W IP65 W11D605H90(mm) YS-F-V027A-R Rotation 3type, Blinking 2type, Flashing 5type 100H 139(mm) Lighting area10091.9mm Operating Temperature
-10+60 5. Specification TAGs Operating Temperature
-10+50
-10+50 Transmission frequency 315MHz 315MHz Model number Battery Battery life
(Operating time) Alarm mode Low battery LED Dustproof and water resistant Weight Dimension W, D, H STANDARD ALERT YS-F-T008A YS-F-T003A Coin Battery
(CR2032) AAA Battery 2 About a year About a year No yes 25g IP65 equivalent Buzzer
& Vibration yes
100g 406712.3 66.59221 DETECTOR (YS-F-R023A) 200 Label O Y G O K A W A K I H S O Y 8 4 8 0 A R
S Y
K R W A 2
D I C C F A 3 2 0 R
F
S Y L E D O M 4 2 1 0 0 0
. o N L A I R E S 0 5 1 6 7 FUSE POWER ALERM RANGE STANDARD-TAG (YS-F-T008A)
. 3 2 1 7 6 Battery 000126 YOSHIKAWA KOGYO YS-F-T008A FCC ID:2AWRK-YS-KT008 40 Battery ALERT 2 9 ON / OFF YS-F-T003A YOSHIKAWA KOGYO FCC ID: 2AWRK-YS-KT008 66.5 Battery 000126 YOSHIKAWA KOGYO YS-F-T008A FCC ID:2AWRK-YS-KT008 32 1 3 ON / OFF 80mm YS-F-T003A YOSHIKAWA KOGYO FCC ID: 2AWRK-YS-KT008 54.6mm ALERT-TAG (YS-F-T003A) 1 2 Battery ALERT FCC CAUTION FCC two conditions:
Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. No. Model Name Model number FCC ID DETECTOR Speaker YS-F-R023A YS-F-S003A 2AWRK-YS-RA0848 Out of scope Indicator lamp YS-F-V027A-R Out of scope STANDARD-TAG YS-F-T008A 2AWRK-YS-KT008 (Original) ALERT-TAG YS-F-T003A 2AWRK-YS-KT008 (Variant) Thin-ALERT-TAG YS-K-T010 Out of scope 1 2 3 4 5 6