SP230/SP230-S5
2x2 PtP/PtMP 802.11ac Wave 2 Access Point
QSG
Revision: 3.3.0.4
Page i
SP230/SP230-S5
2x2 PtP/PtMP 802.11ac Wave 2 Access Point
QSG
Package Contents
One access point
One clamp
Two waterproof cable glands
One ground wire
One mounting bracket
+ Four screws
Note: SP230 and SP230-S5 both provides two waterproof cable glands.
Installation Requirements
TERMS OF USE: All Ethernet cabling runs must use CAT5e, 24 AWG (or above) Shielded Twisted
Pair (STP) cabling. In addition, please cut the cable into a proper length, strip the cables on both
ends, and crimp the wires into RJ45 connectors. It is the professional installer’s responsibility to
follow local country regulations, including operation within legal frequency channels, output power,
indoor cabling requirements, and Dynamic Frequency Selection (DFS) requirements.
Mounting the Access Point on the Pole
Attach the mounting bracket to the device
using four screws (included in the packaging).
Securely tighten the screws.
Attach the clamp to encircle pole and the
mounting bracket. Securely tighten the clamp.
Note: Please avoid having obstacles or metal plates surround the access point.
58-140007-IQN _V1.0
Page 1
2x2 PtP/PtMP 802.11ac Wave 2 Access Point
SP230/SP230-S5
Two-dimensional Mounting Kit (Optional accessory_SP-MKM5)
Pole-Mount
Attach the intermediate steel plate to the
Attach the two-dimensional mounting
QSG
device using four M5 screws (included in the
bracket to the intermediate steel plate using
packaging). Securely tighten the screws.
four M4 screws (included in the packaging).
Securely tighten the screws.
Attach the pole-supported bracket and align the area where the flat head screws will be
attached. Insert two flat head screws into two-dimensional mounting bracket, and tighten
them approximately.
Note: The pole-supported bracket can accommodate up to 6 cm (2.36”) in diameter.
Wall-Mount
Separate it into two parts: half-mounting
bracket and M-type bracket and unscrew
using four M5 screws (included in the
four hex head machine bolts on the two-
packaging). Securely tighten the screws.
dimensional mounting bracket.
Attach the intermediate steel plate to the device
Attach half-mounting bracket to the device
Attach M-type bracket to the device onto the
with intermediate steel plate using four M4
wall, using four M5 screws + screw anchors
58-140007-IQN _V1.0
Page 2
SP230/SP230-S5
2x2 PtP/PtMP 802.11ac Wave 2 Access Point
screws (included in the packaging).
Securely tighten the screws.
screws.
QSG
(included in the packaging). Securely tighten the
Attach half-mounting bracket to the M-type bracket, then screw four hex head machine bolts.
Securely tighten the screws.
Anti-theft Steel Rope (Optional accessory_SP-CBM5)
Insert three anti-theft screws (included in
the packaging) to the device through the
mounting bracket. Securely tighten these
three screws. Attach the clamp to encircle
pole and the mounting bracket. Securely
tighten the clamp.
Firstly, encircle the Anti-theft steel rope as
following left diagram, then encircle on the pole.
Secondly, insert the last anti-theft screw (included
in the packaging) to the device with anti-theft steel
rope. Securely tighten the screw.
58-140007-IQN _V1.0
Page 3
SP230/SP230-S5
Grounding Connection & Protect from Lightning
1. Make your device GND port connect to ground wire.
2x2 PtP/PtMP 802.11ac Wave 2 Access Point
QSG
2. The ground wire connects to the earth. In addition, the
grounding wire meets to 6-AWG copper grounding wire.
Note: Be sure that grounding is available and that it
must comply with local and national electrical codes.
For additional lightning protection, use lightning rods
and lightning arrestors.
Safety Notice
1. Do not install the device close to any electrical grounding device or lightning protection system.
Place the device’s own grounding and lightning protection system apart from any electrical
grounding device and lightning protection system as far as possible.
2. Protect components from electrostatic discharge: Please wear an ESD wrist strap or handle the
power adapter by its edge and do not touch any component or printed circuit boards,
especially for module device.
3. Make sure to keep the temperature and humidity of the installation location at an optimal
level.
4. An excellent grounding system guarantees the stable operation of device, as well as to protect
device from lightning, interference and electrostatic discharges.
5. Supply stable power to the device. Unstable power may cause the device to malfunction. The
device supports PoE power supply and is recommended if the device is installed near grid lines
within less than 100 meters radius.
Installing a Waterproof Cable Gland for Ethernet Port
(Optional accessory_ SP-WP-CM20)
Dismantle all the components of waterproof cable gland, and plug the cable
through it. Thread and assemble one by one: (1) sealing nut (2) plastic ring (3)
rubber (4) locking nut. Securely tighten all the components.
58-140007-IQN _V1.0
Page 4
SP230/SP230-S5
Powering the Access Point
Connect the PoE cable into the WAN/PoE IN port of the device.
2x2 PtP/PtMP 802.11ac Wave 2 Access Point
QSG
Note: Please wait for 5-10 seconds while powering on.
Note: For PoE Out applications, the LAN port provides DC 48V, Max. 208mA, and up to
10W power supply. The positive side of the 48V is connected to pin 4 and 5, the negative
side is connected to pin 7 and 8.
Warning: Do NOT attempt to connect any non-PoE devices to LAN port and make sure
the input power should comply with PoE Out standard.
LED Indicator
Color
Red
Green
Behavior
Steady
Flashing
Steady
Flashing
Description
Initializing
Power / system on
Internet connection detected
No internet connection detected
Access Point Configuration
The SP230 default AP mode is TAP mode, which obtains IP addresses from DHCP Option 43
protocol. The SP230-S5 is FAP mode.
Note: In TAP mode, the AP must be able to go with wireless LAN controllers (WLCs) for
bulk configuration and performing other commands of access points. Please refer to WLC
QSG for settings first, then go back to finish the AP configuration.
https://www.zcom.com.tw/index/downloads?keyword=&meterial_type=49
Step 1. Power on the AP. As the status of LED indicator from flashing change to steady green, the
connection is successful.
Note: Please make sure DHCP server is enabled on the network once accomplished WLC
settings. The access point must receive its IP address through DHCP server.
Note: Switching from DHCP to assign a static IP address or DNS and L2 discovery mode
to the access point, please refer to the user manual for more information.
https://www.zcom.com.tw/index/downloads?keyword=&meterial_type=25
If the access point cannot connect to WLC by DHCP broadcast, please refer to the following
optional settings.
Optional: Set up a static IP address
58-140007-IQN _V1.0
Page 5
SP230/SP230-S5
2x2 PtP/PtMP 802.11ac Wave 2 Access Point
QSG
Note: The following procedure assumes that Windows 10 is the operating system.
Procedures for other operating systems are similar.
Step 1. On your computer, configure your network adapter from the “Local Area Connection
“settings as follows:
˙ StartControl PanelNetwork & InternetChange Adapter OptionsEthernet
Step 2. Edit the TCP/IPv4 address setting as follows:
˙ PropertiesInternet Protocol Version 4(TCP/IPv4)
Step 3. Select “Use the following IP address” and make the following entries:
˙
IP address: 192.168.1.168 (or any available address in the 192.168.1.x network, except
192.168.1.1)
˙ Subnet mask: 255.255.255.0
Leave the “Use the following DNS server address” field empty.
Step 4. Click “OK” to save your changes.
Login into the access point
Step 5. Launch a Web browser; type default URL https://192.168.1.1 to connect to the access
point. When a security alert dialog box appears, click OK/Yes to proceed.
Step 6. When login page appears, enter the following: Username: root/Password: password
Step 7. Click login.
Customizing the Wireless Settings
On the Web interface menu, Select StatusGeneral in the menu bar. Check your switchmod item
to select “Connect with via IP”, and setup your WLC IP address on “Wireless Switch Address 1”.
Note: IP address of WLC needs to be assigned (ex. 192.168.1.228) while on operation.
Note: If you need a standalone access point, please change to FAP mode.
FAP Mode
The default AP mode is TAP mode, before FAP configurations please change AP mode.
Step 1. Currently in TAP Mode: On the Web interface menu, click SystemAP mode.
Step 2. Select Fat AP from the drop-down list.
Step 3. Click save & apply to take effect.
Note: For FAP mode, please refer to the user manual for more information.
https://www.zcom.com.tw/index/downloads?keyword=&meterial_type=25
Bridge Mode
Bridge mode allows two or more wireless access points to communicate with each for the purpose
of joining multiple LANs. The default AP mode is TAP mode, before bridge mode configurations
please change to FAP mode.
58-140007-IQN _V1.0
Page 6
2x2 PtP/PtMP 802.11ac Wave 2 Access Point
QSG
Note: For bridge mode settings, please refer to the user manual for more information.
https://www.zcom.com.tw/index/downloads?keyword=&meterial_type=25
Technical Specifications
151 x 75.5 x 235 mm
(5.94 x 2.97 x 9.25 in)
WAN/PoE In Port One 10/100/1000 Mbps port
Weight
1000 grams (2.2 lbs.)
LAN Port
One 10/100/1000 Mbps port
SP230
SP230-S5
2.4GHz: Embedded 5.5 dBi antennas
5GHz: Embedded 6.5 dBi antennas
2.4GHz: Embedded 5.5 dBi omni antenna
5GHz: Embedded 10.43 dBi directional antennas
Power Supply
DC 48V, 0.5A PoE
LAN/PoE Out
48V/10 Watts (Max.), Passive PoE (Pairs 4, 5+; 7, 8 Return)
Power Consumption Max. 12 Watts
Environmental
Temperature
Humidity
Operating
Storage
-40°C to 70°C (-40°F to 158°F)
10% to 90% (Non-condensing)
-40°C to 80°C (-40°F to 168°F)
10% to 90% (Non-condensing)
SP230/SP230-S5
Physical
Dimensions
(L x W x H)
Antenna
58-140007-IQN _V1.0
Page 7
SP230/SP230-S5
2x2 PtP/PtMP 802.11ac Wave 2 Access Point
QSG
Compliance
FCC CAUTION
Changes or modifications not expressly approved by the party responsible for compliance could
void the user's authority to operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions.
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause
undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to pro-vide reasonable protection
against harmful interference when the equipment is operate din a commercial environment.
This equipment generates, uses, and can radiate radiofrequency energy and, if not installed and
used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own expense.
This radio transmitter has been approved by FCC.
Note: Operations in the 5.15-5.25GHz band are restricted to indoor usage only.
You are cautioned that changes or modifications not expressly approved by the part responsible
for compliance could void the user’s authority to operate the equipment.
Radiation Exposure Statement
•
•
•
This equipment complies with radiation exposure limits set forth for an uncontrolled
environment.
This equipment should be installed and operated with minimum distance 26 cm between the
radiator and your body.
This transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter.
CE Marking
applicable to it.
CE marking on this product represents the product is in compliance with all directives that are
58-140007-IQN _V1.0
Page 8
SP230/SP230-S5
2x2 PtP/PtMP 802.11ac Wave 2 Access Point
QSG
Country List
BFWA (Broadband Fixed Wireless Access) members noted in blue
Note: This device meets Max. TX power limit per ETSI regulations.
The following apply to products that operate in the 5 GHz frequency range:
Note: This device is restricted to indoor use only when operating in the 5150 - 5350 MHz
frequency range within all member states.
Note: Operation in the 5.8 GHz frequency band is prohibited in BFWA member states.
Other countries listed may use the 5.8 GHz frequency band.
WEEE Compliance Statement
European Directive 2012/19/EU requires that the equipment bearing this symbol on the product
and/ or its packaging must not be disposed of with unsorted municipal waste. The symbol
indicates that this product should be disposed of separately from regular household waste streams.
It is your responsibility to dispose of this and other electric and electronic equipment via
designated collection facilities appointed by the government or local authorities. Correct disposal
and recycling will help prevent potential negative consequences to the environment and human
health. For more detailed information about the disposal of your old equipment, please contact
your local authorities, waste disposal service, or the shop where you purchased the product.
EU Declaration of Conformity
Hereby, Z-COM, Inc. declares that the radio devices are in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following internet address:
https://www.zcom.com.tw/index/downloads?keyword=&meterial_type=56
NCC Statement (NCC 警語)
根據 NCC「低功率電波輻射性電機管理辦法」規定:
經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均不得擅自變更頻率、加大功
率或變更原設計之特性及功能。
低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象時,應立即停用,並
改善至無干擾時方得繼續使用。前項合法通信,指依電信法規定作業之無線電通信。低功率射
頻電機須忍受合法通信或工業、科學及醫療用電波輻射性電機設備之干擾。
• 減少電磁波影響,請妥適使用。
• 本產品使用安裝時,應避免影響附近雷達系統之操作。
• 本產品使用時,建議至少距離人體 26cm 以上。
58-140007-IQN _V1.0
Page 9
2x2 PtP/PtMP 802.11ac Wave 2 Access Point
QSG
Picture
SP230
SP230-S5
V
V
SP230/SP230-S5
Optional Accessories
PN
SP-CBM5
Item
Anti-theft steel rope
+ allen wrench + four screws
Two-dimensional mounting kit
• Two-dimensional mounting bracket
• Pole-supported bracket
• Intermediate steel plate
• Two flat head screws
• Four self-tapping screws
• Four screw anchors
• Four machine screws (M4)
• Four machine screws (M5)
SP-MKM5
V
V
SP-WP-CM20
Waterproof cable gland
SP-48063-XX
48V PoE Injector + power cord
V
V
V
V
Note: When ordering power adaptors, you must specify the destination region by
indicating -US, -EU instead of -XX.
Contact Information
All information may be changed by Z-COM at any time without prior notice or explanation to the
user. For further information please refer to our website: www.zcom.com.tw
58-140007-IQN _V1.0
Page 10