all | frequencies |
|
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|---|
manual | photos | labels |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
user-manual | Users Manual | 1.57 MiB | June 29 2020 | |||
1 |
|
Internal Photos | Internal Photos | 1.99 MiB | June 29 2020 | |||
1 |
|
EXT PHOTO | External Photos | 2.47 MiB | June 29 2020 | |||
1 |
|
Label | ID Label/Location Info | 625.92 KiB | June 29 2020 | |||
1 |
|
Label and Label Location | ID Label/Location Info | 246.57 KiB | June 29 2020 | |||
1 | Block Diagram | Block Diagram | June 29 2020 | confidential | ||||
1 |
|
Differences Declaration | Cover Letter(s) | 155.28 KiB | June 29 2020 | |||
1 |
|
FCC Long Term Confidentiality Request Rev4.1 | Cover Letter(s) | 101.75 KiB | June 29 2020 | |||
1 |
|
GTS202005000207F01 2.4G | Test Report | 3.23 MiB | June 29 2020 | |||
1 |
|
Letter of Authorization | Cover Letter(s) | 15.76 KiB | June 29 2020 | |||
1 | Operation Description | Operational Description | June 29 2020 | confidential | ||||
1 | Schematic | Schematics | June 29 2020 | confidential | ||||
1 |
|
Test Setup Photos | Test Setup Photos | 853.39 KiB | June 29 2020 |
1 | user-manual | Users Manual | 1.57 MiB | June 29 2020 |
Hanshow ESL Controller HS_C09959 Product Manual HS-AP-GEN3001 V1.0.2 For more information, visit our website at: http://www.hanshow.com Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 STATEMENT This document and all its contents contained remain the proprietary material of Zhejiang Hanshow Technology Co., Ltd. (Hanshow) and are protected by Chinese laws and applicable international conventions on copyrights. Any reproduction, transmission, disclosure, revision, modification or use otherwise of this document or the whole or part of its contents, in whatever form and by whatever means, is not permitted without prior express written authorization from Hanshow. Offenders will be liable for any and all damages caused by their offence hereof and will be subject to all remedies that Hanshow is entitled to seek under applicable laws. I Hanshow Copyright Reserved Zhejiang Hanshow Technology Co., Ltd. Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 ABOUT THE MANUAL The manual mainly introduces the role of HS_C09959, functional, hardware parameters, features and precautions, as well as all the information that can help you install and achieve good performance. Thank you very much for using the HS_C09959 of Hanshow. Please read the product manual carefully before using this product, retain the document for subsequent use or for the next owner. If the instructions contained in this manual are insufficient to resolve issues that occur during device operation or maintenance, please contact Hanshow Technical Customer Service Center (400-0365-305) directly, we will provide you with multi-channel technical services. TARGET USERS This document provides engineers with necessary data and related guidelines. Users have to master the basic knowledge on communication, DSP, network and so on. This manual is applicable for the below engineers:
Testing Engineer Technical Support Engineer After Sales Engineer Installation Engineer II Hanshow Copyright Reserved Zhejiang Hanshow Technology Co., Ltd. Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 SYMBOL DESCRIPTION Icon Description Information indicated with this icon should be paid special attention and attached great importance by the reader Information indicated with this icon is the explanation on the formal text for the readers to comprehend the text better
[X-X]
It means special noun definition is provided here EXPLANATION OF TERMS Acronym Expanded form Description Wireless Access Point ESL controller Electronic Shelves Label ESL Wireless Fidelity Wireless Fidelity Bluetooth Bluetooth Radio Frequency Electromagnetic frequency that can radiate into space AP ESL Wi-Fi BT RF III Hanshow Copyright Reserved Zhejiang Hanshow Technology Co., Ltd. Table of Contents Table of Contents STATEMENT ................................................................................................................................ I ABOUT THE MANUAL ................................................................................................................ II TARGET USERS ......................................................................................................................... II SYMBOL DESCRIPTION ........................................................................................................... III EXPLANATION OF TERMS ....................................................................................................... III Table of Contents ...................................................................................................................... IV 1 Overview ................................................................................................................................... 1 1.1 System architecture of ESL controller ........................................................................... 1 1.2 Features ......................................................................................................................... 2 2 Hardware feature ...................................................................................................................... 3 2.1 Basic configuration ........................................................................................................ 3 2.2 Physical interface........................................................................................................... 5 2.3 Indicator meaning .......................................................................................................... 6 2.4 Nameplate information .................................................................................................. 7 2.5 Status code meaning ..................................................................................................... 8 2.6 View parameter .............................................................................................................. 8 3 Product installation ................................................................................................................... 9 3.1 Installation requirements ............................................................................................... 9 3.2 Installation accessories ............................................................................................... 10 4 Product operation ................................................................................................................... 11 4.1 Key operation ............................................................................................................... 11 4.1.1 Press ................................................................................................................... 11 4.1.2 Press and hold .................................................................................................... 11 4.2 Parameter setting ........................................................................................................ 12 4.2.1 Homepage .......................................................................................................... 12 4.2.2 Network setting ................................................................................................... 14 4.2.3 ESL-Working setting ........................................................................................... 15 4.2.4 Reboot AP........................................................................................................... 16 4.2.5 AP description ..................................................................................................... 18 4.2.6 Change admin password .................................................................................... 19 4.2.7 Restore factory settings ...................................................................................... 19 4.2.8 Upgrade firmware ............................................................................................... 20 5 Workflow ................................................................................................................................. 21 6 Package .................................................................................................................................. 22 6.1 Package drawing ......................................................................................................... 22 6.2 Package contents ........................................................................................................ 22 7 Precautions ............................................................................................................................. 23 IV Hanshow Copyright Reserved Zhejiang Hanshow Technology Co., Ltd. Table of Contents 8 FCC ID warning ...................................................................................................................... 24 8.1 Warning for nameplate ................................................................................................ 24 8.2 Warning for product manual ........................................................................................ 24 V Hanshow Copyright Reserved Zhejiang Hanshow Technology Co., Ltd. List of Figures List of Figures Figure 1-1 Overall system architecture of ESL controller ...................................... 1 Figure 2-1 External interface of HS_C09959 ......................................................... 5 Figure 2-2 Front panel of HS_C09959 ................................................................... 6 Figure 2-3 Nameplate information for HS_C09959 ................................................ 7 Figure 3-1 HS_C09959 installation ........................................................................ 9 Figure 3-2 Standard installation accessories for HS_C09959 ............................. 10 Figure 3-3 Assembly drawing for HS_C09959..................................................... 10 Figure 4-1 Login page ......................................................................................... 12 Figure 4-2 Configuration homepage .................................................................... 13 Figure 4-3 Network configuration page ................................................................ 14 Figure 4-4 ESL-Working setting ........................................................................... 15 Figure 4-5 Reboot device .................................................................................... 17 Figure 4-6 AP description .................................................................................... 18 Figure 4-7 Change password .............................................................................. 19 Figure 4-8 Restore factory settings ...................................................................... 20 Figure 6-1 Package of HS_C09959 ..................................................................... 22 VI Hanshow Copyright Reserved Zhejiang Hanshow Technology Co., Ltd. List of Tables List of Tables Table 2-1 Basic configuration for HS_C09959....................................................... 3 Table 2-2 Function description for each interface .................................................. 5 Table 2-3 Status code meaning ............................................................................. 8 Table 2-4 HS_C09959 view parameter ................................................................. 8 Table 4-1 Configuration item description ............................................................. 13 Table 4-2 Configuration item description ............................................................. 14 Table 4-3 Configuration item description ............................................................. 15 Table 7-1 Precautions and suggestions .............................................................. 23 VII Hanshow Copyright Reserved Zhejiang Hanshow Technology Co., Ltd. Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 1 Overview HS_C09959 is the third generation wireless Access Point (AP) researched and developed independently by Hanshow Technology Co., Ltd, which is highly integrated to meet rapid development of new-generation AP. HS_C09959 achieves higher performance, smaller volume and low power, making customer to have a better data services experience. HS_C09959 works at the wireless frequency band of 2.4G. It is response for the data transmission and information interaction between ESL and ESL-Working, which adopts the design of modular and omnidirectional internal antenna, one ARM A7 processor, and integrates RF module, as well as supporting all software and hardware products of Hanshow. 1.1 System architecture of ESL controller ESL controller system consists of ShopWeb, ESL-Working, ESL controller (AP), Electronic Shelves Label (ESL) and Hand-hold Terminal (PDA), interacting with ESL and ESL-Working, the system architecture as shown in Figure 1-1. Figure 1-1 Overall system architecture of ESL controller The HS_C09959 is an integral part of Hanshow electronic shelf label system, to be as data transmission links and responsible for data forwarding. HS_C09959 connects to electronic working system via Ethernet interface (POE), and establishing bi-directional 2.4GHz wireless communication with ESL. Downlink: HS_C09959 could receive downlink packets from ESL-Working via wireless network, and send variable price, inventory and template data to ESL. 1 Hanshow Copyright Reserved Zhejiang Hanshow Technology Co., Ltd. Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 Uplink: HS_C09959 will forward heartbeats data and other information to ESL-
Working platform based on the ESL wireless protocol standard. 1.2 Features The main features of HS_C09959 are as follows:
Operation System (OS): embedded Linux operation system, it works for data interaction with ESL-working system, including the registration of ESL controller system, heartbeat reception, data transmission, and support for on-line upgrade, etc. Radio frequency system: support four way RF subsystem, and support concurrent communication in order to ensure communicate success rate, reduce the packet loss and improve the efficiency of channel. Memory: support 512MB DDR3L + 256MB NandFlash Compatibility: support all Hanshow series label, including label with LCD and EPD screen Multiple power supply: support power supply by POE and AC/DC power adapter Administration configuration: support Web configuration mode LED light: LED light real-time display working status 2 Hanshow Copyright Reserved Zhejiang Hanshow Technology Co., Ltd. Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 2 Hardware feature This chapter presents the information, including the basic configuration, physical interface, indicator meaning, nameplate information, status code information and view parameter. 2.1 Basic configuration HS_C09959 has the following basic configuration, as shown in Table 2-1. Table 2-1 Basic configuration for HS_C09959 Other Overload/over-voltage/over-temperature protection HS_C09959 specifications Power supply module Input voltage DC 12V or POE 802.3af/at Rated current 1A (adapter)/350 mA (POE) Rated power 12W CPU Memory OS Main processor module 528MHz ARM 512MB DDR3L + 256MB NandFlash Linux 4.1.15 RF module (2.4G Module) Working frequency 2402 MHz ~ 2480 MHz Transmit power 6dBm by default Antenna gain 2dBi Antenna features Four omni-directional antenna Ultra high sensitivity
-95dBm at 500Kbps
-97dBm at 100Kbps Ethernet module Connection speed 10/100M (adaptive) Auto-negotiation Support 3 Hanshow Copyright Reserved Zhejiang Hanshow Technology Co., Ltd. Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 HS_C09959 specifications Automatic flip DHCP Support Support POE module Input voltage 36 ~ 57V DC Output voltage Rated current Maximum power 12V 1A 12W Standard IEEE 802.3af/at Idle state power 12V, 160mA Maximum power 12V, 370mA Power parameter Temperature Operating temperature 0 ~ 50 Storage temperature
-30 ~ 70 4 Hanshow Copyright Reserved Zhejiang Hanshow Technology Co., Ltd. Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 2.2 Physical interface HS_C09959s physical interfaces are as shown in Figure 2-1, and each interfaces function is illustrated in Table 2-2. Figure 2-1 External interface of HS_C09959 Table 2-2 Function description for each interface No. Interface name Description Press and hold: restore factory settings, press this button for more than 5 seconds, Press: HS_C09959 could switch between enabling DHCP and fixed IP (192.168.1.199), after triggering the function, it will invalid to press in 30 seconds. For detailed information, refer to the section of 4.1. USB2.0 5V/250mA. interface, output current is less than Can connect to DC power adapter that is standard 12V/1A adapter provided by Hanshow 1 Reset button USB interface Power interface 2 3 4 5 6 7 Light Light CONSOLE interface Professionals debug device interface POE interface Adaptive 10M/100M Ethernet, and support IEEE 802.3at/af standard Ethernet power supply LED indicator is used for system status. For more information, refer to section of 2.3 LED indicator is used for network status. For more information, refer to section of 2.3 5 Hanshow Copyright Reserved Zhejiang Hanshow Technology Co., Ltd. Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 No. Interface name Description 8 Light 9 Two-digit nixie tube LED indicator is used for power status. For more information, refer to section of 2.3 Green, which is HS_C09959 ID got from ESL-Working when HS_C09959 is connected to ESL-Working successfully. (The direction of Nixie light is aligned to Hanshow logo direction on the panel.) 2.3 Indicator meaning There are two-digit Nixie light and three LED indicators in the front panel, as shown in Figure 2-2. Figure 2-2 Front panel of HS_C09959 Table 2-2 Nixie light and LED indicators description No. Name Status Description 1 2 Green Green light is always on, and system runs normally System indicator light status Green flashing Green light flashing, and data transmission status. Red Green Red light is always being on, system runs abnormally. Green light is always on, Ethernet link normally, but not connect to ESL-Working Network indicator light status Green flashing Green flashing, Ethernet link normally, and connect to ESL-Working normally Red Red light is always on, Ethernet link 6 Hanshow Copyright Reserved Zhejiang Hanshow Technology Co., Ltd. Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 No. Name Status Description 3 4 Power indicator light Nixie light On Off Number abnormally Green light is on, and AP is powered-on Green light is off, and AP is powered-off AP has been connected to ESL-Working, the number currently is ID, and the range of 1 ~ 99 (if the ID is over 99, just display the last two-digit)
AP is not connected to ESL-Working Notice: Pay attention to note that all system indicators are being on Red firstly once AP powered-on, then they are changing to Green when the system works normally. 2.4 Nameplate information HS_C09959s nameplate information has the following implications, as shown in Figure 2-3. IP address and MAC address are default configuration in HS_C09959. IP address can be modified through configuration page. HS_C09959 supports POE and DC power supply, and either POE or DC, but not both. Figure 2-3 Nameplate information for HS_C09959 7 Hanshow Copyright Reserved Zhejiang Hanshow Technology Co., Ltd. Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 2.5 Status code meaning The definition of two-digit Nixie light displayed on panel is shown as Table 2-3. Table 2-3 Status code meaning Code value Description
AP is not connected to ESL-Working Number DH ST AP has been connected to ESL-Working, and the number currently displayed is ID, the range of 1 ~ 99 (If the ID is over 99, just display the last two-digit). AP is able to switch status between DHCP/Static IP, if switching to DHCP, the nixie light displays DH. AP is able to switch status between DHCP/Static IP, if switching to Static IP, the nixie light displays ST. 2.6 View parameter HS_C09959s view parameter such as structural materials, dimension&weight, and color parameter are shown in Table 2-4. Table 2-4 HS_C09959 view parameter Structural materials The case and the bottom shell ABS plastic material Indicate lampshades Translucent PC Length (mm) Width (mm) Height (mm) Whole belt packing (g) Net weight (g) 505 397 Size 166mm 166mm 40.5mm Weight Color Appearance color Two color selection: white and black 8 Hanshow Copyright Reserved Zhejiang Hanshow Technology Co., Ltd. Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 3 Product installation 3.1 Installation requirements In actual use, HS_C09959 should be installed in a higher position to achieve better transmission and coverage. Moreover, the higher the installation height, the smaller the device spacing should be, as shown in Figure 3-1. Figure 3-1 HS_C09959 installation The recommendations for installation scenario are as follows:
When the shelf height is 3m, H in Figure 3-1 is recommended to 3m ~ 5m, and the coverage radius R is 10 ~ 15m. It is recommended that the installation distance of two Hanshow APs is about 25m, and at least 5m;
When the shelf height is 3 ~ 5m, H in Figure 3-1 is recommended to 5 ~ 8m, and the coverage radius R is 7 ~ 12m. It is recommended that the installation distance of two Hanshow APs is about 20m and at least 5m. Notice:
occlusion. If shelf height exceeds 5m, the installation height of AP is determined according to the actual situation;
The installation height of AP should be higher than shelf height to avoid signal 9 Hanshow Copyright Reserved Zhejiang Hanshow Technology Co., Ltd. Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 3.2 Installation accessories HS_C09959s standard installation accessories and assembly drawing is shown in Figure 3-2 and Figure 3-3. Figure 3-2 Standard installation accessories for HS_C09959 Figure 3-3 Assembly drawing for HS_C09959 Note:
recommended. How to install HS_C09959, Ceiling Horizontal Suspended Mounting is For more detailed information, refer to (HS-AP-GEN3002) Hanshow ESL controller HS_C09959 Installation Manual. 10 Hanshow Copyright Reserved Zhejiang Hanshow Technology Co., Ltd. Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 4 Product operation 4.1 Key operation 4.1.1 Press Reset key supports press and hold and press that owns different function respectively. Press is used to switch IP address acquisition mode. This feature is strictly limited and just to operate when AP is not connected to the network. AP address will switch between DHCP and static IP with each press. When AP works at DHCP client mode, its IP address will get from DHCP server. When AP works at static IP mode, its default settings are: IP --192.168.1.199, Subnet mask -- 255.255.255.0, and Gateway -- 192.168.1.1. The nixie light of AP will also give corresponding prompt:
When AP switches to DHCP mode, nixie light will display DH, and last for 5s. When AP switches to static IP mode, nixie light will display ST, and last for 5s. When AP is not connect to ESL-Working, nixie light is always display --. Note: The protection time between two operations is 30s, that is, if you press again in 30s after the last successful operation, your operation will be invalid. 4.1.2 Press and hold Press and hold reset key is more than 5s, AP will restore factory setting. And the nixie light and LED indicators on the front panel is all being on, about 2s, changing to off, AP will restore factory setting and re-startup. Restore factory setting has the following contents:
Restore to DHCP client mode Restore to auto search mode of ESL-Working Clear the custom description Restore web login password to admin 11 Hanshow Copyright Reserved Zhejiang Hanshow Technology Co., Ltd. Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 HS_C09959 supports Web configuration mode, that is, user can manage the AP via Web. 4.2 Parameter setting 4.2.1 Homepage You can logon the HSC09959 IP address to configure the page. For example: If HS_C09959 IP is 192.168.51.100, logging on to http://192.168.51.100, that is, enter the following page to configure related parameters, as shown in Figure 4-1 and Figure 4-2. Figure 4-1 Login page Note:
logon the homepage. The default password of HS_C09958 is admin, and enter your password to Both Chinese and English are supported on the page, and users can switch the language by the upper right corner. 12 Hanshow Copyright Reserved Zhejiang Hanshow Technology Co., Ltd. Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 Figure 4-2 Configuration homepage HS_C09959s configuration page is as shown in Table 4-1. Table 4-1 Configuration item description Configuration item Description Network ESL-Working Used to set the network parameters of HS_C09959, such as DHCP switch, IP address, subnet mask, etc. ESL-Working IP address, port number and SSL encryption can be set Reboot AP Reboot AP device AP Description Add description information Change admin password Used to modify the password of the configuration page Restore factory settings You can restore the default settings of HS_C09959 Update firmware Software version upgrade for HS_C09959 main system and RF subsystem 13 Hanshow Copyright Reserved Zhejiang Hanshow Technology Co., Ltd. Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 4.2.2 Network setting Network setting is used for setting the network parameter of HS_C09959. IP address acquiring mode includes DHCP or static IP, as show in Figure 4-3. Figure 4-3 Network configuration page The detailed configuration item is illustrated as shown in Table 4-2. Table 4-2 Configuration item description Configuration item Description DHCP When set to OFF, IP address of device should be configured manually;
When set to ON, the device is DHCP client, and IP address should be get from DHCP server. IPv4 address IPv4 address, can configure when the DHCP is OFF. Subnet mask Subnet mask, can configure when the DHCP is OFF. Gateway Gateway, can configure when the DHCP is OFF. DNS Domain Name Server (DNS), Must be set when the ESL-Working address is configured as domain name address;
14 Hanshow Copyright Reserved Zhejiang Hanshow Technology Co., Ltd. Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 Configuration item Description Enable DHCP, to get DNS from DHCP. MAC Unique MAC address of device, refer to nameplate Note: Network modified will effective immediately, and you need to re-enter setting website to access. 4.2.3 ESL-Working setting ESL-Working setting can set IP address and port number of ESL-Working, as shown in Figure 4-4. Figure 4-4 ESL-Working setting Configuration item of network configuration is illustrates as shown in Table 4-3. Table 4-3 Configuration item description Configuration item Description AUTO search When set to OFF, it need to specify relative parameter of ESL-
Working manually. When set to ON, AP will search ESL-Working address in local area network (LAN), as well as accessible to ESL-Working automatically. ESL-Working address The IPv4 or DNS in ESL-Working can configure when AUTO search is set to OFF. 15 Hanshow Copyright Reserved Zhejiang Hanshow Technology Co., Ltd. Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 Configuration item Description Port number of ESL-Working:
When AUTO search is set to ON, this port number is the target one for AP accessible to ESL-Working;
When AUTO search is set to OFF, this port number is the target one for AP accessible to ESL-Working. Whether to use SSL to connect securely with ESL-Working Port number SSL Note:
After the domain name address of ESL-Working is set, you need to check if DNS server is configured correctly. If set to SSL is enabled, please check port number is correct. In general, the part number for connecting/nonconnecting to SSL is different. ESL-Working information modified will take effective about 30s later, no need to Notice: Please make sure to configure ESL-Working address manually when AP and ESL-Working is used in the cross-network segment. restart AP. 4.2.4 Reboot AP Click OK on the homepage, a confirmation box pops up, then to confirm again. The device will reboot, as shown in Figure 4-5. Please wait for about 1min to reboot AP. 16 Hanshow Copyright Reserved Zhejiang Hanshow Technology Co., Ltd. Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 Figure 4-5 Reboot device 17 Hanshow Copyright Reserved Zhejiang Hanshow Technology Co., Ltd. Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 4.2.5 AP description The description setting item of HS_C09959 can add custom device information description for record and recognition, as shown in Figure 4-6. Figure 4-6 AP description 18 Hanshow Copyright Reserved Zhejiang Hanshow Technology Co., Ltd. Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 4.2.6 Change admin password Change admin password is used for changing the password of configuration page, as shown in Figure 4-7. Figure 4-7 Change password 4.2.7 Restore factory settings It can restore the factory setting of AP. You need to check again on the pop-up dialog, click OK. The AP will restore factory setting and restart, as shown in Figure 4-8. Please wait for about 1min to restore factory setting. 19 Hanshow Copyright Reserved Zhejiang Hanshow Technology Co., Ltd. Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 Figure 4-8 Restore factory settings Note:
The effect is the same as the press button. Dont cut off the power during the process of restoring factory setting, otherwise the device will be damaged. 4.2.8 Upgrade firmware Upgrade firmware: Used for on-line upgrading of main system and RF subsystem. Notice:
damaged. Dont cut off the power during upgrading process, otherwise the system will be Upgrade the main PCB and four-way sub-PCB of RF. The whole upgrading process takes about 10 min. For more detailed information, please refer to (HP-AP-GEN3003) ESL Controller HS_C09959 Upgrade Manual. 20 Hanshow Copyright Reserved Zhejiang Hanshow Technology Co., Ltd. Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 5 Workflow 1. Before starting HS_C09959, please check if the power cord and network cable are connected correctly in first. 2. Whether to use the standard 12V adapter or POE mode power supply 3. After powered-on, the power indicator on the HS_C09959 panel is on and the system starts to boot. 4. The startup time is about 1min. After the system is started, both of system status light and network status light is on, all of which indicate working status. 5. After the system starts, please follow the section of 4.2 to configure HS_C09959s IP and ESL-Workings IP. 6. HS_C09959 will automatically connect to ESL-Working after the configuration is correct. If success, network status indicator will display green; if failed, it will timing reconnect until connection is successful. 7. After HS_C09959 is connected to ESL-Working, the two digital tubes will display HS_C09959 ID. And HS_C09959 can perform data communication operations, including heartbeat reception, data transceiver, and label inquiry, etc. 21 Hanshow Copyright Reserved Zhejiang Hanshow Technology Co., Ltd. Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 6 Package 6.1 Package drawing HS_C09959s physical packaging is shown as Figure 6-1. Figure 6-1 Package of HS_C09959 HS_C09959 device (with the product model on the nameplate) 6.2 Package contents HS_C09959s package contains:
Sheet metal mounting bracket Screws Metal cable tie Quick Start Guide 22 Hanshow Copyright Reserved Zhejiang Hanshow Technology Co., Ltd. Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 7 Precautions When installing and using HS_C09959 (hereinafter referred to as AP), please pay attention to the following precautions and suggestions:
Table 7-1 Precautions and suggestions Item Description Pre-installation check Before connecting the cables, please use the testing tool to check if the network cable is normal, and ensure AP can work normally. Installation scenario Avoid metal interference around the AP, especially the cage interference effect. Install network cable The cable is ultra 5 type and higher. Installation distance If the shelf height is 3m, it is recommended that the installation distance of two Hanshow APs is about 25m, and at least 5m;
If the shelf height is 3 ~ 5m, it is recommended that the installation distance of two Hanshow APs is about 20m and at least 5m;
If shelf height exceeds 5m, the installation height of AP is determined according to the actual situation;
Keep the distance not less than 2m from operator 4G;
The installation height of AP should be higher than shelf height to avoid signal occlusion. Installation check loosening and falling-off. Make sure the installation is fixed firmly in case of the Never cable of POE into CONSOLE interface. Network settings It is suggested to set the channel of 2.4GHz as 1, 6 or 11 in case of using 2.4GHz Wi-Fi. It is required to stagger the time of RF optimization and ESL updating if users want to use 2.4GHz Wi-Fi. is required to allocate It the 2.4GHz wireless communication channel in advance in void of disturbance if other Internet of Things devices with 2.4GHz frequency band are used (such as Zigbee and BT). 23 Hanshow Copyright Reserved Zhejiang Hanshow Technology Co., Ltd. Hanshow ESL Controller HS_C09959 Product Manual V1.0.2 8 FCC ID warning 8.1 Warning for nameplate This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. 8.2 Warning for product manual Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. 24 Hanshow Copyright Reserved Zhejiang Hanshow Technology Co., Ltd.
1 | Differences Declaration | Cover Letter(s) | 155.28 KiB | June 29 2020 |
Differences Declaration To whom concern, We company Zhejiang Hanshow Technology Co., Ltd. hereby declares: The product models HS_C09989 are identical in the same PCB layout, interior structure and electrical circuits with the model HS_C09959 which tested in Global Unit Technology Co., Ltd., the only difference is that several resistors are welded in different positions.Different welding positions of resistors represent different hardware types and realize different software functions. Differences in software functionality do not affect any hardware performance, including rf performance.This difference is mainly due to different business logic for different application scenarios, such as large malls, small convenience stores, and so on. Authorized signature:
Date: 2020/06/02
1 | FCC Long Term Confidentiality Request Rev4.1 | Cover Letter(s) | 101.75 KiB | June 29 2020 |
< Zhejiang Hanshow Technology Co., Ltd. >
Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD21046 Date: 2020-06-05 Subject; Request for Long Term Confidentiality FCC ID: 2AHB5-C09959 To Whom It May Concern, Pursuant to the provisions of the Commissions rules Title 47 Sections 0.457 and 0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Operational Description It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature:
Name: Xiaochen Jia Title: manager
1 | Letter of Authorization | Cover Letter(s) | 15.76 KiB | June 29 2020 |
Zhejiang Hanshow Technology Co., Ltd. Letter of Authorization Company: Zhejiang Hanshow Technology Co., Ltd. Address: Bld. 33, No. 966 xiuyuan Rd., BeiKeJian Innovation Park, XiuZhou District, Jiaxing, Zhejiang, China Product Name: ESL Controller Model Number(s): HS_C09959, HS_C09989 Product Description: ESL Controller We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature:
Date: 2020-06-05 Name:
Xiaochen Jia Title:
manager Company: Zhejiang Hanshow Technology Co., Ltd.
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2020-06-29 | 2402 ~ 2480 | DXX - Part 15 Low Power Communication Device Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2020-06-29
|
||||
1 | Applicant's complete, legal business name |
Zhejiang Hanshow Technology Co., Ltd.
|
||||
1 | FCC Registration Number (FRN) |
0025221466
|
||||
1 | Physical Address |
Bld. 33, No. 966 xiuyuan Rd., BeiKeJian Innovation Park, XiuZhou District, Jiaxing, Zhejiang, China
|
||||
1 |
Bld. 33, No. 966 xiuyuan Rd., BeiKeJian Innovation
|
|||||
1 |
Jiaxing, N/A
|
|||||
1 |
China
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
c******@micomlabs.com
|
||||
1 | TCB Scope |
A2: Low Power Transmitters (except Spread Spectrum) and radar detectors operating above 1 GHz
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
2AHB5
|
||||
1 | Equipment Product Code |
C09959
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
X**** J****
|
||||
1 | Telephone Number |
86-13********
|
||||
1 | Fax Number |
86-05********
|
||||
1 |
x******@hanshows.com
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
Zhejiang Hanshow Technology Co., Ltd.
|
||||
1 | Physical Address |
China
|
||||
1 |
x******@hanshows.com
|
|||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DXX - Part 15 Low Power Communication Device Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | ESL Controller | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Global United Technology Services Co. Ltd.
|
||||
1 | Name |
R**** L******
|
||||
1 | Telephone Number |
86-0-********
|
||||
1 |
r******@gtstest.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 2402.00000000 | 2480.00000000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC