all | frequencies |
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|
manual | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User manual | Users Manual | 3.07 MiB | January 30 2024 | |||
1 |
|
Internal Photos | Internal Photos | 834.67 KiB | January 30 2024 | |||
1 |
|
External Photographs of EUT | External Photos | 586.51 KiB | January 30 2024 | |||
1 |
|
Label | ID Label/Location Info | 86.25 KiB | January 30 2024 | |||
1 |
|
Agent Authorization | Cover Letter(s) | 7.40 KiB | January 30 2024 | |||
1 |
|
Antenna Specification | Test Report | 1.02 MiB | January 30 2024 | |||
1 | Block Diagram | Block Diagram | January 30 2024 | confidential | ||||
1 |
|
Certification Equipment Type | Attestation Statements | 168.36 KiB | January 30 2024 | |||
1 |
|
Certificiation Applicant | Attestation Statements | 153.22 KiB | January 30 2024 | |||
1 |
|
Differences Declaration Letter | Cover Letter(s) | 37.41 KiB | January 30 2024 | |||
1 |
|
FCC Short & Long Term Confidentiality Request | Cover Letter(s) | 69.47 KiB | January 30 2024 | |||
1 | Operational Description | Operational Description | January 30 2024 | confidential | ||||
1 |
|
RF Exposure | RF Exposure Info | 482.54 KiB | January 30 2024 | |||
1 | SCH | Schematics | January 30 2024 | confidential | ||||
1 |
|
Test Report | Test Report | 3.84 MiB | January 30 2024 | |||
1 |
|
Test photos | Test Setup Photos | 383.04 KiB | January 30 2024 | |||
1 |
|
US agent | Attestation Statements | 164.54 KiB | January 30 2024 |
1 | User manual | Users Manual | 3.07 MiB | January 30 2024 |
User Manual M1600/1800/2000-SW MICRO INVERTER Carefully read this inverter user instructions before using. Read and save these instructions. 2023 ZHEJIANG HYXI TECHNOLOGY CO., LTD. All rights reserved. This document cannot be copied fully or partially, transferred, or distributed in any form without the prior written permission of ZHEJIANG HYXI TECHNOLOGY CO., LTD ( hereinafter referred to as "HYXIPOWER" ). TRADEMARKS and other HYXIPOWER trademarks are the trademarks or registered trademarks of HYXIPOWER All other trademarks mentioned herein are the properties of their respective owners. i HYX-M1600/1800/2000-SW User Manual HYX-M1600/1800/2000-SW User Manual Contents Contents 1. Safety Instructions ...........................................................................................................................................1 1.1 Safety Instruction .................................................................................................................................................................1 1.2 Symbol Description ...........................................................................................................................................................2 1.2.1 Symbols Used in the Manual ......................................................................................................................................2 1.2.2 Other Symbols .................................................................................................................................................................2 1.3 Radio Wave Interference Statement ..........................................................................................................................2 2. Product Introduction ...................................................................................................................................... 4 2.1 Photovoltaic On-Grid System ........................................................................................................................................4 2.2 Microinverter .......................................................................................................................................................................4 2.3 4-in-1 Microinverter System ..........................................................................................................................................5 2.4 Communication Technology .........................................................................................................................................5 2.5 Product Features ...............................................................................................................................................................5 2.6 Inverter Size and Termnial Instruction ......................................................................................................................6 3. Installation ......................................................................................................................................................... 7 3.1 Mircoinverter System Installation Accessories ......................................................................................................7 3.2 Customer Needs to Provide Tools .............................................................................................................................7 3.3 Installation Procedures....................................................................................................................................................8 3.3.1 How to Make a T-Junction Bus .................................................................................................................................8 3.3.2 Microinverter Installation ............................................................................................................................................9 3.3.3 Connect Microinverter with T-junction ..............................................................................................................10 3.3.4 Connect PV module ..................................................................................................................................................10 3.3.5 Draw Installation Map .................................................................................................................................................11 3.3.6 Operate and Power On ..............................................................................................................................................11 3.3.7 Configure the Gateway...............................................................................................................................................11 4. Fault Clearance ...............................................................................................................................................13 4.1 Status indication and error reporting ......................................................................................................................13 4.1.1 Start indicator ..................................................................................................................................................................13 4.1.2 Operating indicator ......................................................................................................................................................13 4.1.3 Alarm Troubleshooting ...............................................................................................................................................13 4.1.4 On-Site Inspection (qualified installers only) ....................................................................................................16 5. Maintenance Guide ........................................................................................................................................17 5.1 Routine maintenance ...................................................................................................................................................... 17 5.2 Microinverter Replacement ......................................................................................................................................... 17 5.3 Storage and transport ................................................................................................................................................... 17 ii Contents 5.4 End-of-life Disposal ........................................................................................................................................................18 6. Human-Computer Interaction ....................................................................................................................19 6.1 Installing the App .............................................................................................................................................................19 6.2 APP User manual .............................................................................................................................................................19 6.3 System debugging ..........................................................................................................................................................19 7. Appendix ..........................................................................................................................................................20 7.1 Technical Specifications ................................................................................................................................................20 7.2 Wiring Diagram .................................................................................................................................................................21 7.3 Installation Map ................................................................................................................................................................ 22 7.4 Contact Information .......................................................................................................................................................23 iii HYX-M1600/1800/2000-SW User Manual 1. Safety Instructions 1. Safety Instructions HYX-M1600-SW, HYX-M1800-SW, HYX-M2000-SW series microinverters can efficiently convert direct current into alternating current that meets the requirements of the power grid and feed the power into the power grid. They are designed and tested in strict accordance with relevant national safety standards. The installation, trial operation, operation and maintenance of the inverter must comply with relevant safety regulations. Incorrect operation or use will endanger:
Life and personal safety of operators or third parties. Other property of the operators or third parties. Important Safeguards and Warnings To ensure the installation and operation safety of inverter and reduce the risk of electric shock, this manual uses the following safety symbols to mark some danger indications and safety precautions. Safeguards and Warnings in the specific operation process will also be explained in detail in the corresponding chapters. This manual contains important instructions to be followed when installing and maintaining the microinverter. Users should read this manual thoroughly before installing or debugging the microinverter. For safety, the technicians responsible for the installation, operation and maintenance of this microinverter must have corresponding qualifications, received relevant training and master relevant skills. Installation, operation and maintenance must strictly follow the instructions contained in this manual. 1.1 Safety Instruction Only qualified professionals can install and replace the microinverter. The electrical installation of microinverter must comply with local electrical regulations. Read all instructions and warning signs in this manual before installing and using the microinverter. To avoid scalding, do not directly contact the shell of the microinverter, and the shell temperature can reach 80 . Before disconnecting the microinverter from the solar module, the AC side power grid must be disconnected first. If the microinverter does not work normally, contact after sales services of HYXIPOWER. Unauthorized destruction or opening of the microinverter will not be covered by warranty. 1 HYX-M1600/1800/2000-SW User Manual 1. Safety Instructions 1.2 Symbol Description 1.2.1 Symbols Used in the Manual DANGER Indicates dangerous conditions that might cause fatal electric shock risk, serious personal injury or fire. CAUTION To avoid potential safety hazards, the corresponding instructions must be strictly followed. NOTICE This operation is prohibited, and relevant personnel should stop the operation. 1.2.2 Other Symbols Symbol Description Caution When the device is running, do not step within 0.2 m of its periphery. High Voltage The high voltage generated by microinverter can endanger life. High Temperature The microinverter will generate heat during operation. Do not touch the metal surface. Reading Manual Read the users manual carefully before installation, operation and maintenance. CE The microinverter meets EU low voltage standard. Discarding Do not treat the microinverter as domestic garbage. 1.3 Radio Wave Interference Statement After testing, this microinverter meets the requirements of CE and EMC and is free from electromagnetic interference. This product might cause electromagnetic interference if it is improperly installed. You can turn off the microinverter and then start it again to detect whether the radio is interfered by the inverter. If the inverter interferes with radio, take the following measures to eliminate the influence:
2 HYX-M1600/1800/2000-SW User Manual 1. Safety Instructions Relocate the receiving antenna away from other devices. Ncrease the distance between the microinverter and the antenna. Use metal or concrete materials to separate the microinverter from the antenna. Consult a local supplier or skilled radio technician. 3 HYX-M1600/1800/2000-SW User Manual 2. Product Introduction 2. Product Introduction 2.1 Photovoltaic On-Grid System The on-grid system diagram of HYX-M2000-SW series microinverter is as follows:
2.2 Microinverter HYX-M1600-SW, HYX-M1800-SW, HYX-M2000-SW series are 4-in-1 microinverters, which can connect four photovoltaic modules. They are module-level photovoltaic inverters with module-
level monitoring function. The whole system consists of two parts, photovoltaic on-grid power generation system and photovoltaic monitoring system. photovoltaic on-grid power generation system includes photovoltaic modules, microinverter, AC cable and other accessories. Microinverter is the core product of photovoltaic power generation system, and it has independent maximum power point tracking (MPPT) control, which can maximize the energy output of the whole solar array and maximize the power generation performance of photovoltaic system no matter how the array is arranged or when it encounters unsatisfactory conditions such as shadow occlusion, dirt accumulation, illumination deviation or mismatch in practical application. In addition, microinverters do not require the consistency of photovoltaic modules like central and series inverters. Each microinverter transformer can be easily mounted on the rack below the panel. The panel-side low-voltage DC line can be directly connected to the microinverter, eliminating the danger of high-voltage DC voltage. Remote monitoring platform:
The operating data and working status of the inverter are transmitted through the wireless router, and the user is provided with module-level monitoring through the Web or App application to realize remote operation and maintenance. 4 HYX-M1600/1800/2000-SW User Manual 2. Product Introduction 2.3 4-in-1 Microinverter System The DC side can choose a microinverter series according to the number of connected photovoltaic modules. As shown below:
1-in-1 2-in-1 4-in-1 This manual mainly introduces Hyxipower 4-in-1 microinverter series. This series of HYX-M2000-SW has outstanding performance in 4-in-1 series, with an output power up to 2000VA. Each microinverter can be connected to four photovoltaic modules. It has independent MPPT and module-level data monitoring functions, high power generation, easy and convenient maintenance features. 2.4 Communication Technology HYX-M2000-SW microinverter series adopts a new wifi wireless communication solution. Wi-Fi communication solution: It operates in the 2.4GHz frequency band, and the transmission distance is weaker than the Sub-1G frequency band. It does not need additional communication equipment and can directly communicate with Hxyi Cloud. 2.5 Product Features Maximum output power 2000W. Module-level MPPT, the peak conversion efficiency reaches 96.7%. IP67 enclosure, 6000V surge protection for higher reliability. 5 HYX-M1600/1800/2000-SW User Manual 2.6 Inverter Size and Termnial Instruction 2. Product Introduction AAC Branch Connector BAntenna CDC terminal 6 HYX-M1600/1800/2000-SW User Manual 3. Installation 3. Installation Each microinverter is installed on a mount just below the solar module panel. The low-voltage DC line on the panel side of the solar module can be directly connected to the microinverter, but it must be protected from direct sunlight, rain, snow, ultraviolet rays, etc. A clearance of at least 20mm should be left around the microinverter enclosure to ensure ventilation and heat dissipation. CAUTION The instructions in the manual must be followed when moving and placing the device. Mishandling of equipment may result in minor, serious injury or contusion. The cooling fins of the device must be left uncovered to ensure sufficient internal cooling of the device. 3.1 Mircoinverter System Installation Accessories Image Description Image Description T-junction cable T-junction bus end plug M8*25 bolt (Self preparation) T-junction removal tool T-junction bus connector T-junction branch line port protection cover
*The above accessories are not included in the product package and need to be purchased separately. 3.2 Customer Needs to Provide Tools 7 HYX-M1600/1800/2000-SW User Manual 3. Installation 3.3 Installation Procedures 3.3.1 How to Make a T-Junction Bus Step 1: Prepare several sections of T-junction connecting wires according to the number of microinverters to be installed on site. Step 2Removing the T-junction cable at the end. Use the T-knot removal tool to remove the lower cover. Loosen the inner screw, unscrew the nut, and remove the cable. Install a T-junction bus end plug at the end of the T-junction. Insert the lower T-junction cover back into place and make sure it is secure. Step 3 T-junction and bus connection Prepare the AC cable by stripping the ends. Insert the AC cable into the T-junction connector at the correct hole position. Tighten the screws, and then the nuts. Insert the lower T-junction cover back into place, making sure it is secure. 8 HYX-M1600/1800/2000-SW User Manual Step 4: Secure the T-junction cable Put the T-junction connecting wire on the guide rail and fix it with cable tie. 3. Installation CAUTION Nut tightening torque2.50.5NmScrew tightening torque0.80.1NmDo not over-tighten, Do not damage the sealing ring in the T-junction connector during assembly and disassembly. Do not contact T-junction bus connectors with water directly. Use a professional tool to uninstall the T-junction bus connector. 3.3.2 Microinverter Installation Step1 Mark the installation position of the microinverter on the bracket According to the layout of the photovoltaic modules. Step 2: Fix the microinverter on the bracket with M8*25 screw, then lock the screw. (* The inverter indicator panel should face the bracket ) CAUTION Install the microinverter and all DC connections under the PV module to avoid direct sunlight, rain and snow, etc. Leave 20mm space between Microinverter and PV module for Ventilation and heat dissipation. Screw tightening torque: 9NmDo not over-tighten. Do not carry AC cables during transportation. 9 HYX-M1600/1800/2000-SW User Manual 3.3.3 Connect Microinverter with T-junction Insert the output AC feeder connector of the microinverter into the T-junction bus connector until hearing a "click" sound. Ensure that the installation is tight. 3. Installation 3.3.4 Connect PV module Step 1Install the PV module above the microinverter. Step 2Connect the DC output cable of the PV module with the input side of the microinverter. CAUTION Ensure that the output current and voltage of the PV modules are consistent with the inverter. Operating DC voltage range of the PV module must be within the input voltage range of the microinverter. The maximum Voc of the PV module shall not exceed the maximum input voltage of the microinverter . DC output power of PV module shall not exceed 1.5 times that of the AC output power of the microinverter. 10 HYX-M1600/1800/2000-SW User Manual 3. Installation 3.3.5 Draw Installation Map Tear off the serial number label of microinverter and affix serial number label on the corresponding position according to the installation map for quick identification during maintenance. 3.3.6 Operate and Power On Step 1: Close the main Grid circuit breaker. Step 2: Close the AC circuit breaker of each microinverter branch, and the system will automatically generate power after about 2 minutes. Step 3: Set up monitoring system on Hyxipower Smart PV Cloud Platform. 3.3.7 Configure the Gateway Step 1: Two ways of microinverter configuer network. Method 1: Before login A: Open app and click the "More". B: Click the "Wi-Fi Config". 11 HYX-M1600/1800/2000-SW User Manual 3. Installation Method 2: After login A: Log in to the app and click the "Me". B: Click the "Tool". C: Click the "Wi-Fi Config". Step 2Choose Wi-Fi connection method, then Search for microinverter Wi-Fi:MI-
XXXXXXXXXXX, enter the Wi-Fi default password: 12345678. Step 3Choose nearby Wi-Fi and enter the password. Step 4Click "Start To Configure The Wi-Fi", wait to configuer the network countdown. CAUTION If multiple devices need to be connected, repeat the same steps. 12 HYX-M1600/1800/2000-SW User Manual 4. Fault Clearance 4. Fault Clearance Only qualified professionals can implement the following troubleshooting operations when the microinverter solar system is not working properly. 4.1 Status indication and error reporting 4.1.1 Start indicator When the DC side of the microinverter is powered on for the first time :
The green lights blinks briefly indicates startup success. The red lights blinks briefly indicates startup failure. 4.1.2 Operating indicator Light Status Meaning Light Status Meaning Fast flashes (1s gap) Normal Light on Ground error Green Slow flashes (3s gap) Communication error Red Slow flashes (5s gap) PV input error Fast flashes (1s gap) Fast flashes (2s gap) Error AC error 4.1.3 Alarm Troubleshooting Fault code Fault description Solution 3073 PLL Phase lock 3074 3075 PV1-PV4 Circuit undervoltage PV1-PV4 Circuit overvoltage 3076 PV1-PV4 over-current 1. It may be a short-time grid abnormality when occurs occasionally. It will resume work without manual intervention after the grid is normal. 2. Check AC connection when the fault occurs frequently. 3. Contact the distributor if the cable connection and power grid are normal. 1. If the input voltage is too high, ensure that the input voltage of PV module is not higher than the maximum input voltage of the microinverter. 2. If the input voltage is low or zero, ensure that the component is properly connected. 3. Contact the distributor If the component voltage is within the normal range. 1. If the input current is too high, ensure that the input voltage of PV module is not higher than the maximum input voltage of the microinverter. 2. Contact the distributor If the component voltage is within the normal range. 13 HYX-M1600/1800/2000-SW User Manual 4. Fault Clearance Fault code Fault description Solution 3091 3092 PV-1 & PV-2 terminal connection fault PV-3 & PV-4 terminal connection fault 1. Check if the terminal connect to the PV module. 2. Check if the port is properly connected if connection is fine. 3082 Island protection 3083 Insultation resistance 3084 Device overheating 3086 The grid voltage fluctuates too much instantaneously 3087 3088 3090 EEPROM data corruption EEPROM data corruption Flash data corruption 1. Occasionally, it may be a short-term power grid abnormality. When the power grid is normal, it will resume work without manual intervention. 2. If all the microinverters in the power station have frequent islanding alarms, please contact the power bureau to confirm whether there is indeed an islanding phenomenon and solve it. 3. If the problem still cannot be solved, please try to contact the equipment manufacturer or dealer. 1. Check whether the wiring on the input side of the microinverter is normal. 2. Check whether the modules (junction box) are normal. 1. Check whether the ambient temperature of the microinverter exceeds the maximum allowable temperature. 2. If the ambient temperature exceeds the allowable temperature, please improve the installation environment. If the environment is normal, please contact the dealer or equipment manufacturer. 1. Occasionally, it may be a short-term power grid abnormality. When the power grid is normal, it will resume work without manual intervention. 2. If it occurs frequently, please confirm whether the grid voltage is normal. If the whole station alarms, please contact the local power bureau to solve the problem or adjust the instantaneous fluctuation limit of the grid voltage through the monitoring platform after obtaining the consent of the power bureau. 1. Occasionally, and the microinverter works normally without manual intervention. 2. It keeps appearing and cannot be recovered, the microinverter cannot work normally, Please contact your dealer or device. 14 HYX-M1600/1800/2000-SW User Manual 4. Fault Clearance Fault code Fault description Solution 3097 3098 3099 3100 1. If the input DC current is too high, please ensure that the input photovoltaic module current is not higher than the maximum input PV1- PV4 Primary side current of the microinverter. hardware overcurrent 2. If the module current is within the normal range for three days and the microinverter does not work, please contact the dealer or equipment manufacturer. 1. If the input DC voltage is too high, please PV1-PV4 absorption capacity ensure that the input photovoltaic module overvoltage voltage flow is not higher than the maximum Inverter bridge 1 hardware input voltage of the microinverter. overcurrent 2. If the module voltage is within the normal Inverter bridge 2 hardware range for three days and the microinverter overcurrent does not work, please contact the dealer or equipment manufacturer. 1. Confirm whether the anti-backflow is enabled. 3094 Remote shutdown 2. If the anti-backflow is not enabled,
Firmware error Low power generation please contact the dealer or equipment manufacturer. 1. Please confirm whether the upgraded firmware is correct, and re-upgrade. 2. Please confirm whether the communication between the microinverter and the platform is normal, and re-upgrade when connected to the grid. 3. If the fault still exists, please contact the equipment manufacturer or dealer. 1. If it occurs occasionally, it may be a short-
term power grid abnormality. When the power grid is normal, it will resume work without manual intervention. 2. If all the microinverters in the power station have frequent islanding alarms, please contact the power bureau to confirm whether there is indeed an islanding phenomenon and solve it. 3. If the problem still cannot be solved, please try to contact the equipment manufacturer or dealer. 15 HYX-M1600/1800/2000-SW User Manual 4. Fault Clearance 4.1.4 On-Site Inspection (qualified installers only) If the microinverter fails, please troubleshoot according to the following steps:
Step 1Verify whether the grid voltage and frequency are within the range specified in the technical parameter table of the user manual. Step 2: Check the connection to the grid. Disconnect the AC side first, then the DC side. When the inverter is still working, it is forbidden to disconnect its DC side connection. Reconnect the DC side and observe whether the indicator light flashes green briefly three times. Step 3: Check the connection of each microinverter in the AC branch, and confirm whether each microinverter is powered by the public grid. Step 4: Make sure that each AC circuit breaker is functioning normally and is in a closed state. Step 5: Check the connection between the microinverter and the DC side of the solar module. Step 6: Verify whether the DC voltage of the solar module is within the range specified in the technical parameter table of the user manual. Step 7: If the problem persists, please call Hyxipower's customer support number. Precautions for routine maintenance:
DANGER Do not attempt to repair the microinverter, if troubleshooting fails, return it to the factory for a replacement. Do not disassemble and repair the microinverter by yourself ! In order to ensure safety and insulation performance, users are prohibited from repairing internal parts. CAUTION Do not replace the AC input harness ( AC tap cable on the microinverter ). If the wire is damaged, the equipment should be scrapped. Unless otherwise specified, the connection between the equipment and the power grid ( disconnect the power switch ) must be cut off during maintenance, while shielding or isolating photovoltaic modules. Do not use rags made of filamentous or corrosive materials to clean the equipment, otherwise it may cause corrosion or generate static electricity. Do not repair the product without authorization. Qualified parts must be used for maintenance. NOTICE Each branch line should be equipped with a circuit breaker. 16 HYX-M1600/1800/2000-SW User Manual 5. Maintenance Guide 5. Maintenance Guide 5.1 Routine maintenance 1Only authorized personnel are allowed to perform maintenance operations and are responsible for reporting abnormal conditions. 2Wear personal protective equipment for maintenance operations. 3In normal operation, check the environment. Make sure that the environment does not meet the normal working requirements of the microinverter due to time changes, and ensure that the microinverter is not exposed to harsh weather and is not covered by foreign objects. 4Do not disassemble the microinverter or open the case for maintenance. In order to ensure safety and insulation integrity, the design of the microinverter does not allow the case to be opened for maintenance. 5.2 Microinverter Replacement Replacement of miniature inverter The following steps shall be followed when replacing the failed miniature inverter converter on site:
Step 1: Disconnect the power supply of the branch circuit AC side circuit breaker. Step 2: Disconnect the AC bus from the AC connector of the inverter. Step 3: Remove the PV modules from the rack. Step 4: Use the DC disconnect tool to disconnect the solar module and the DC connector of the microinverter. Step 5: Use the AC disconnect tool to disconnect the AC connectors of the failed microinverter and the adjacent microinverter. Step 6: Unscrew the fixing screws on the top of the microinverter and remove the device from the PV rack. Step 7: Install the new microinverter on the rack, and observe the blinking of the indicator light when the DC line is reconnected. Step 8: Connect the replacement microinverter's AC cables to the AC bus. Step 9: Close the branch circuit breaker to verify the operation of the replacement microinverter transformer. 5.3 Storage and transport In order to facilitate transportation and subsequent handling, HHYXIPOWER packaging adopts a special design to protect each component. When transporting equipment, especially by road, protect components from severe moisture, shocks, vibrations, etc. After receiving the microinverter, please check whether the outer packaging is damaged. If the outer packaging appears damaged, call the carrier immediately. After unpacking, please check whether the appearance of the inverter is damaged and whether the accessories are complete. In case of damage to the microinverter or missing parts, please 17 HYX-M1600/1800/2000-SW User Manual 5. Maintenance Guide contact the supplier or authorized dealer of Hxyi to apply for repair/replacement and consult the relevant procedures. The storage temperature of the microinverter should be maintained between -40 C to +85 C. 5.4 End-of-life Disposal If the device is no longer in use or needs to be stored for a long time, please make sure that the packaging is intact. Store the device in a well-ventilated indoor area that will not cause damage to device components. When restarting equipment that has been out of service for a long time, a complete inspection of the equipment must be carried out. Capacitors, modules and other components contained in the microinverter will pollute the environment, please dispose of them according to local regulations and laws. 18 HYX-M1600/1800/2000-SW User Manual 6. Human-Computer Interaction 6. Human-Computer Interaction 6.1 Installing the App Method 1 Download and install the App through the following application stores:
App Store (iOS). Google App market (Android, users other than mainland China ones). Method 2 Scan the following QR code to download and install the App according to the prompt information:
6.2 APP User manual For more information on using the HYXiPower APP, please refer to the user manual "HYXiPower APP". 6.3 System debugging For system configuration and debugging, please refer to the user manual "HYXipower Local Debugging APP". 19 HYX-M1600/1800/2000-SW User Manual 7. Appendix 7. Appendix 7.1 Technical Specifications Product Model Input (DC) HYX-M1600-SW HYX-M1800-SW HYX-M2000-SW Typical module compatibility 320 - 600 W 360 - 670 W 400 - 670 W Min./Max. MPPT voltage Operating voltage range Max. input voltage Start-up input voltage Max. input current Max. short-circuit DC input current Number of MPP trackers OVC categorie Max. backfilling current Output (AC Rated output power Rated output current Rated output voltage Nominal frequency 16 - 60V 16 - 60V 65V 20V 16A/16A/16A/16A 20A/20A/20A/20A 4 0A 1600VA 6.96A 1800VA 7.83A 2000VA 8.70A 220 / 230 / 240 / 183~276V 50 / 45 - 55, 60 / 55 - 65Hz Power factor (adjustable)
>0.99 / 0.8 leading0.8 lagging THDi Current (inrush) Max. output fault current Max. output overcurrent protection OVC categorie Protective class 26A/15us
< 3%
26A/15us 20A peak 20A Class Max. current of AC cable 40A10AWG30A12AWG 26A/15us Efficieny Peak efficiency Nominal MPPT efficiency CEC peak efficiency Night-time power loss Protection Input reverse connection protection Output overcurrent protection Output overvoltage protection Anti-islanding protection Surge protection 96.70%
99.80%
96.30%
30mW Yes Yes Yes Yes Type 20 HYX-M1600/1800/2000-SW User Manual 7. Appendix HYX-M1600-SW HYX-M1800-SW HYX-M2000-SW
-40 to +65 310*236*35.5mm IP67 Natural convection - No fans 4.8kg 0-100% RH PD3 Outdoor 3000m Built-in WiFi Hyxi Cloud Galvanically Isolated HF Transformer Product Model General Data Operating ambient temperature Dimensions (W*H*D) Enclosure rating Cooling Weight Relative humidity Class of pollution Work environment Operating altitude Features Communication Monitoring Type of isolation 7.2 Wiring Diagram 230VAC/400 VAC Three-phase grounding map 21 HYX-M1600/1800/2000-SW User Manual 7. Appendix 230V Single Phase Grounding Map 7.3 Installation Map 22 HYX-M1600/1800/2000-SW User Manual 7. Appendix 7.4 Contact Information If you have any questions about this product, please contact us !
In order to provide you with faster and better after-sales service, we need your assistance to provide the following information:
Device model Devise serial number Fault code/name Brief description of the fault phenomenon 23 HYX-M1600/1800/2000-SW User Manual Version: v1.0 2023 The manual is subject to change without notice while the product is being improved. Zhejiang Hyxi Technology Co., Ltd. 9-10F, Building 3, Jiuyao Commercial Center, Zhuantang Sub-district, Xihu District, Hangzhou, Zhejiang Province, China, 310008 support@hyxipower.com www.hyxipower.com FCC Warning This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator &
your body. IC Warning This device complies with Industry Canadas licence-exempt RSSs. Operation is subject to the following two conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including interference that may cause undesired operation of the device. This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. Cet appareil est conforme aux CNR exemptes de licence d'Industrie Canada . Son fonctionnement est soumis aux deux conditions suivantes :
( 1 ) Ce dispositif ne peut causer d'interfrences ; et
( 2 ) Ce dispositif doit accepter toute interfrence , y compris les interfrences qui peuvent causer un mauvais fonctionnement de l'appareil. Ce matriel est complt par une exposition de rayonnements IC pour un environnement naturel. Ce matriel doit tre install et se faire avec une distance minimale de 20cm entre les radiateurs et les autresYour body shop.
1 | Label | ID Label/Location Info | 86.25 KiB | January 30 2024 |
FCC/IC Label HYX 4-in-1 MICRO INVERTER HYX-M2000-SW-NA FCC ID: 2BDBN-4MSWG1 IC: 31516-4MSWG1 Size: 40*30mm The label is printed on the shell
1 | Agent Authorization | Cover Letter(s) | 7.40 KiB | January 30 2024 |
Zhejiang Hyxi Technology Co., Ltd. Agent Authorization Company name: Zhejiang Hyxi Technology Co., Ltd. Address: 9-10F, Building 3, Jiuyao Commercial Center, Zhuantang Street, Xihu District, Hangzhou, Zhejiang, China Product Name: HYX 4-in-1 MICRO INVERTER FCC ID: 2BDBN-4MSWG1 Model(s): HYX-M2000-SW-NA, HYX-M1600-SW-NA, HYX-M1800-SW-NA We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature:
Name:
Bin Hu Title:
Manager Company: Zhejiang Hyxi Technology Co., Ltd. Date: 2024.01.18
1 | Certification Equipment Type | Attestation Statements | 168.36 KiB | January 30 2024 |
Zhejiang Hyxi Technology Co., Ltd. Section 2.911(d)(5)(i) Certification Equipment Type Company name: Zhejiang Hyxi Technology Co., Ltd. Address: 9-10F, Building 3, Jiuyao Commercial Center, Zhuantang Street, Xihu District, Hangzhou, Zhejiang, China Product Name: HYX 4-in-1 MICRO INVERTER FCC ID: 2BDBN-4MSWG1 Model(s): HYX-M2000-SW-NA, HYX-M1600-SW-NA, HYX-M1800-SW-NA 2.911(d)(5)(i) Equipment Type We, [Zhejiang Hyxi Technology Co., Ltd.] (the applicant) certify that the equipment for which authorization is sought through certification is not:
Prohibited from receiving an equipment authorization pursuant to 2.903; of the FCC rules. Identified as an equipment type in the Covered List NOTE 1 Yours sincerely, Name: Bin Hu Date: 2024.01.18 Title and Company name: Manager Zhejiang Hyxi Technology Co., Ltd. NOTE 1 Covered List; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References;
1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the 2.911 (d)(5)(i) Equipment Type Attestation v1.2
1 | Certificiation Applicant | Attestation Statements | 153.22 KiB | January 30 2024 |
Zhejiang Hyxi Technology Co., Ltd. Section 2.911(d)(5)(ii) Certification Applicant (Covered List ) Company name: Zhejiang Hyxi Technology Co., Ltd. Address: 9-10F, Building 3, Jiuyao Commercial Center, Zhuantang Street, Xihu District, Hangzhou, Zhejiang, China Product Name: HYX 4-in-1 MICRO INVERTER FCC ID: 2BDBN-4MSWG1 Model(s): HYX-M2000-SW-NA, HYX-M1600-SW-NA, HYX-M1800-SW-NA 2.911(d)(5)(ii) Applicant filing We, [Zhejiang Hyxi Technology Co., Ltd.] (the applicant) certify that, as of the date of the filing of the application, the applicant is not identified NOTE 1 on the Covered List NOTE 2, established pursuant to 1.50002 of this chapter, as an entity producing covered communications equipment. Yours sincerely, Name: Bin Hu Date: 2024.01.18 Title and Company name: Manager Zhejiang Hyxi Technology Co., Ltd. NOTE 1 Delete option not applicable to this application. NOTE 2 Covered List; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References;
1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the 2.911 (d)(5)(ii) Applicant Attestation v1.3
1 | Differences Declaration Letter | Cover Letter(s) | 37.41 KiB | January 30 2024 |
Differences Description We Zhejiang Hyxi Technology Co., Ltd. state:
Product HYX 4-in-1 MICRO INVERTER Model Name HYX-M2000-SW-NA, HYX-M1600-SW-NA, HYX-M1800-SW-NA Brand Name N/A Motherboard, hardware, software, appearance, etc. are the same, only difference in model name. Sincerely, Signature:
Name:
Bin Hu Title:
Company: Zhejiang Hyxi Technology Co., Ltd. Manager Date: 2024.01.18
1 | FCC Short & Long Term Confidentiality Request | Cover Letter(s) | 69.47 KiB | January 30 2024 |
Zhejiang Hyxi Technology Co., Ltd. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Subject; Request for Confidentiality FCC ID: 2BDBN-4MSWG1 Date: 2024.01.18 To Whom It May Concern, Pursuant to the provisions of the Commissions rules Title 47 Sections 0.457 and 0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR 2.803 and the importation rules in Title 47 CFR 2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s);
External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature:
Name:
Bin Hu Title:
Manager Company: Zhejiang Hyxi Technology Co., Ltd. Date: 2024.01.18
1 | US agent | Attestation Statements | 164.54 KiB | January 30 2024 |
AOGES CO., LIMITED Section 2.911(d)(7) USA Agent for Service of Process Company name: Zhejiang Hyxi Technology Co., Ltd. Address: 9-10F, Building 3, Jiuyao Commercial Center, Zhuantang Street, Xihu District, Hangzhou, Zhejiang, China Product Name: HYX 4-in-1 MICRO INVERTER FCC ID: 2BDBN-4MSWG1 Model(s): HYX-M2000-SW-NA, HYX-M1600-SW-NA, HYX-M1800-SW-NA 2.911(d)(7) USA Designated Agent for Service of Process We, [Zhejiang Hyxi Technology Co., Ltd.] (the applicant) designate [AOGES CO., LIMITED] NOTE1 for the purpose of accepting service of process on behalf of the applicant. Applicant consent: We acknowledge our consent to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and email address of the designated agent and acknowledge our acceptance of our obligation to maintain an agent for service of process in the United States for no less than one year after either we the grantee have permanently terminated all marketing and importation of the applicable equipment within the U.S., or at the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. Agent obligation: We acknowledge our obligation to accept service of process in the United States for matters related to the applicable equipment at our physical U.S. address and email address for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or at the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. USA Agent Company name: AOGES CO., LIMITED USA Address: 1624 Market St., Ste 226,
#30327 Denver CO, 80202 US FRN Number 0033947847 Contact Name: XIAOYAN LAI Telephone No: +1 303 623 1940 Email: xiaoyanlai15@gmail.com Applicant Company name: Zhejiang Hyxi Technology Co., Ltd. Address: 9-10F, Building 3, Jiuyao Commercial Center, Zhuantang Street, Xihu District, Hangzhou, Zhejiang, China Grantee FRN Number0034399766 FCC Grantee Code: 2BDBN Contact Name: Bin Hu Telephone No: 18072760424 Email: hu_bin@hyxipower.com 2.911 (d)(7)USA Agent v1.5 Signature:
Title: General Manager AOGES CO., LIMITED Signature:
Title: Manager Date:2024.01.18 Date:2024.01.18 NOTE 1: An applicant located in the United States may designate itself as the agent for service of process. Reference; Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-nation al-security-threats-to-the-communications-supply-chain-through-the 2.911 (d)(7)USA Agent v1.5
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2024-01-30 | 2412 ~ 2462 | DTS - Digital Transmission System | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2024-01-30
|
||||
1 | Applicant's complete, legal business name |
Zhejiang Hyxi Technology Co., Ltd.
|
||||
1 | FCC Registration Number (FRN) |
0034399766
|
||||
1 | Physical Address |
9-10F, Building 3, Jiuyao Commercial Center, Zhuantang Street, Xihu District
|
||||
1 |
9-10F, Building 3, Jiuyao Commercial Center
|
|||||
1 |
Hangzhou, Zhejiang,, N/A
|
|||||
1 |
China
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
c******@micomlabs.com
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
2BDBN
|
||||
1 | Equipment Product Code |
4MSWG1
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
B**** H********
|
||||
1 | Title |
Manager
|
||||
1 | Telephone Number |
18676********
|
||||
1 | Fax Number |
18676********
|
||||
1 |
2******@qq.com
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
Zhejiang Hyxi Technology Co., Ltd.
|
||||
1 | Physical Address |
China
|
||||
1 |
h******@hyxipower.com
|
|||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DTS - Digital Transmission System | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | HYX 4-in-1 MICRO INVERTER | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
SHENZHEN STS TEST SERVICES CO.,LTD.
|
||||
1 | Name |
B**** Y****
|
||||
1 | Telephone Number |
+86 7********
|
||||
1 |
B******@stsapp.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 2412.00000000 | 2462.00000000 | 0.0513000 |