User Manual rev1 part1 | Users Manual | 4.54 MiB | November 09 2023 / November 13 2023 | |||
1 |
|
User Manual rev1 part2 | Users Manual | 2.28 MiB | November 09 2023 / November 13 2023 | |||
1 |
|
Internal Photo | Internal Photos | 716.42 KiB | November 09 2023 / November 13 2023 | |||
1 |
|
External Photo | External Photos | 621.85 KiB | November 09 2023 / November 13 2023 | |||
1 |
|
Label and Location | ID Label/Location Info | 1.47 MiB | November 09 2023 / November 13 2023 | |||
1 |
|
230101492SHA-001 Test Report rev1 | Test Report | 676.22 KiB | November 09 2023 / November 13 2023 | |||
1 |
|
230101492SHA-002 Report FCC SAR Test Exclusion | RF Exposure Info | 391.28 KiB | November 09 2023 / November 13 2023 | |||
1 |
|
ACB-Covered-List-Attestation | Attestation Statements | 140.94 KiB | November 09 2023 / November 13 2023 | |||
1 |
|
ACB-FCC-Agency-Letter | Cover Letter(s) | 46.27 KiB | November 09 2023 / November 13 2023 | |||
1 |
|
ACB-FCC-Confidentiality-Letter | Cover Letter(s) | 105.85 KiB | November 09 2023 / November 13 2023 | |||
1 |
|
ACB-U.S.-Agent-Letter rev1 | Attestation Statements | 152.36 KiB | November 09 2023 / November 13 2023 | |||
1 |
|
Antenna Declaration Letter | Test Report | 91.06 KiB | November 09 2023 / November 13 2023 | |||
1 | Confidential Block Diagram | Block Diagram | November 09 2023 | confidential | ||||
1 | Confidential Operation Description | Operational Description | November 09 2023 | confidential | ||||
1 | Confidential Schematic | Schematics | November 09 2023 | confidential | ||||
1 |
|
Test Setup | Test Setup Photos | 233.90 KiB | November 09 2023 / November 13 2023 |
1 | User Manual rev1 part1 | Users Manual | 4.54 MiB | November 09 2023 / November 13 2023 |
111 DA e-Motion+
THANK YOU FOR PURCHASING OUR MIRADOR e-Motion+
This manual will provide you with clear and detailed instructions on how to safely and correctly assemble and maintain your pergola, to ensure it brings you many years of use and enjoyment. IMPORTANT Warning: Important safety instructions. It is important for the safety of persons to follow these instructions. Save these instructions. This product can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the product in a safe way and understand the hazards involved. Children shall not play with the product. Cleaning and user maintenance shall not be made by children without supervison. Intended use This pergola is intended for outdoor domestic use in residential environments, and to protect users from direct sunlight, glare and heat . Any use or modification to the pergola not included in this manual shall be considered as improper use, which may cause considerable danger to users and property and will void the product warranty. For parts and customer service, please call 1-800-867-9018 in the U.S. and Canada (English and Spanish)Monday Friday, 8:30 am to 4:30 pm, Pacific Time. Or email: support@miradoroutdoor.com Digital instruction manual is also available on our official website www.miradoroutdoor.com for your reference. Mirador_111 DA e-Motion+_4_Pillar_EN_23v2.0 1 TABLE OF CONTENTS
- Before Assembling Your Pergola
- Important Safety Advice
- Technical Data
- List of Parts
- Installation
- Operation of Your Mirador Pergola
- Problem Solving, Care & Maintenance
- Warranty & Complaints Procedure
- Disassembly and Disposal of the Product
- Certification Information 3 5 9 10 12 34 35 38 39 40 2 BEFORE ASSEMBLING YOUR PERGOLA WARNING: Improtant safety instructions. Follow all instructions, since incorrect installation can lead to severe injury. Make sure you have all the tools required for assembling your pergola In order to assemble your pergola safely and correctly, please ensure you have access to the following tools and accessories, all of which are not provided. Hard hat Protective gloves Box cutter Tape measure Spirit level Phillips screwdriver Cordless screwdriver Hexagonal spanner/
wrench set Hammer drill Hammer 2 step ladders Scissors 3 Check to ensure there are no missing parts Before you begin installation, please check that you have all the parts required to assemble your e-Motion. Please also carefully check that the quantity of parts match with that of the model you have purchased. If any parts are missing, please refer Warranty & Complaints Procedure to contact customer service before beginning the installation. Prepare the parts you will need for each step In the Installation section of the manual, each step indicates the necessary parts and quantities required to complete the step. We recommend that you prepare the parts you will need for each installation step. Doing this will save you time and effort during assembly. If possible, place the parts on cardboard or other soft surface to protect from scratching the painted surfaces. Select a suitable location:
The ground should be solid and flat The ground should be level Sufficient water drainage Easy access to power No overhanging trees and powerlines
>2.5 Warning:
Most terraces or patios are designed with a slight slope to prevent (rain) water from forming pools or reaching the house or other structures. For the perfect pergola installation, a level concrete surface without such a slope is required. Small pebbles could also prevent the pergola from being safely secured on the ground. If the pergola is installed on an uneven surface, it may prevent accessory components from working correctly and may void the product warranty. Prepare a foundation:
To prepare it, you need to:
- check for underground pipes and cables (Call 811 before you dig if you live in the USA)
- check with your local authorities regarding any building permits that may be required
- contact a reliable contractor to have concrete base if you dont have one Do not assemble the pergola on sandy, muddy or loose soil, as the stakes do not have the suffcient anchorage to be installed in these types of soil. 4 IMPORTANT SAFETY ADVICE For the safety of all persons installing and using the pergola, it is important to follow the safety guidelines below. The pergola must be positioned and fixed on flat level surface. Always wear appropriate work shoes, gloves and eye protection when working. Work well away from power lines, particularly when handling metal parts. If using power tools or a ladder, always follow the manufacturers safety instructions. Make sure the pergola complies with local building regulatory codes. Working at heights can be dangerous. Always wear protective clothing to prevent injury in the event of a fall. Only use ladders and scaffolding with a sufficiently high load bearing capacity. Before installing the drive, remove any unnecessary cords and disable any equipment not needed for powered operation. 5 Hazardous unprotected moving parts of the drive shall be installed higher than 2.5m above the floor or other level that could provide access to it. Keep clothing and body parts away from the pergola to prevent them from getting caught in the moving parts. Foliage or other foreign objects on the louvers and in the guide rails should be removed regularly, to prevent damage to the pergola. Put the louvers into the vertical position during snowfall or wind to avoid damage.
2.5m Only use replacement parts that are approved by the manufacturer. Electrical installation may only be carried out by certified personnel according to the applicable regulation. (e.g. VDE 100 for europe) Make sure all electrical connections are disconnected from the mains during installation. Mirador electric pergolas should only be connected to power sources that have been installed by a licensed electrical contractor. Approved The pergola should only be remote controlled when you have a full view of the moving parts. Installation of non-Mirador branded accessories will void the product warranty and can damage the operating mechanism. Dispose of all plastic bags safely. Keep them out of the reach of children. Keep children and pets away from the assembly area until the work is completed. Mirador 6 Changes to the design or configuration of equipment may not be made without consulting the manufacturer or authorized representative. Hot items such as recently used grills, fire pits etc. must not be stored under or close of the pergola. Prior to each operation, visually check the pergola for damage. If damage is visible, stop using it immediately and contact authorized personnel to repair the damage. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified people in order to avoid a hazard. Do not climb on the louvers. Do not touch moving parts during operation. Do not place anything on the louvers. Do not attempt to assemble the pergola in windy or wet conditions. Do not start the roof mechanism in case of frost or ice build-up, as it may damage the drive of the louvers. Do not allow children to contact the fixed controls. Keep remote controls away from children. Hanging objects on the pergola may cause serious damage and is not permitted. 7 WARNING:
When using outdoor use portable lighting products, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and personal injury, including the following:
WARNING WARNING WARNING WARNING Do not mount or support flexible light in a manner that can damage the outer jacket or cord insulation. Risk of Fire and Electric Shock. Uncoil flexible light prior to plugging in. Do not install near flammable liquids. Material may become brittle when cold. Do not install where it may be stepped on or subject to physical damage. Use only outdoor extension cords, such as type SW, SOW, STW, STOW, SJW, SJOW, SJTW, or SJTOW. This designation is marked on the wire of the extension cord. CAUTION CAUTION CAUTION Suitable for outdoor use. Risk of Electric Shock. Do not use with extension cord near water or where water may accumulate. For use only on GFCI protected circuits. 8 TECHNICAL DATA Pergola Linear Actuator Control Box Continuous Operating Cycle Sound Pressure Level Ingress Protection Rating Wind Resistance Input Voltage Ingress Protection Rating Input Voltage Output Voltage Ingress Protection Rating Input Voltage Light LED Strip Wattage Per Meter Ingress Protection Rating Input Voltage Power supply Ingress Protection Rating Maximum Power Control Method 10 cycles 70 dB IPX5 Class 6/ 9 BFT 24V DC IP66 24V DC 24V DC IPX5 24V DC 10W IP67 100 to 240V IP67 350W Remote Control + App Control Control LTE Max Transmit power 23dBm2dBm LTE Frequency band B1, B3, B7, B8, B20, B28A, B38, B40 Remote control frequency band 2400MHz~2483MHz Remote control Max Transmit power 0dBm Data Center North America Europe West Coast: Oregon East Coast: Virginia Sweden Amsterdam Frankfurt 9 LIST OF PARTS PLEASE NOTE that the anchor bolts provided may not be suitable for your chosen installation location. Please check before proceeding. DO NOT USE AN IMPACT CORDLESS SCREW DRIVER TO ASSEMBLE THE PERGOLA. USE A STANDARD CORDLESS SCREW DRIVER ON THE BASE SETTING. ALL HOLES HAVE BEEN PREDRILLED OR FITTED FOR ASSEMBLY. REF Part name QTY
(3x3m) QTY
(3x3.6m)
(3.6x3.6m) QTY
(3x4m)
(3.6x4m) A A2 B1 B2 C D G 10 Standard corner pillar 3 Cabled corner pillar Side beam with motor Side beam without motor End beam Louver Connecting strip 1 1 1 2 19 1 3 1 1 1 2 3 1 1 1 2 23 25 1 1 REF Part name QTY
(3x3m) QTY
(3x3.6m)
(3.6x3.6m) QTY
(3x4m)
(3.6x4m) REF Part name QTY
(3x3m) QTY
(3x3.6m)
(3.6x3.6m) QTY
(3x4m)
(3.6x4m) I J K L M N O P Q R S W X Y Z Foot plate cover Foot plate 4 4 4 4 4 4 Louver end cap Louver end cap with control arm Shaft support cover 37+2 45+2 49+1 1 1 1 38+2 46+2 50+2 Z4 Pillar cover 4 4 4 Z5 Screw ST5.65x 45mm Screw M5x 12mm Screw 4.2x 25mm Screw 5.5x 19mm 24+2 24+2 24+2 76+4 92+5 100+5 76+4 92+5 100+5 12+2 12+2 12+2 Z6 Z7 Z8 Z9 Cotter pin 19+3 23+3 25+4 Z10 Anchor bolt M8x80mm Hex key
(small) Hex key
(large) 12mm SDS Plus Drill Bit Power supply LED light strip Remote control 2.4G and 4G Antenna Waterproof tape Screw ST4.8x 13mm Spare plastic pin 16 16 16 1 2 1 1 2 1 1 1 4 1 2 1 1 2 1 1 1 4 1 2 1 1 2 1 1 1 4 0+10 0+10 0+10 11 INSTALLATION 1. Set up the corner pillars 1A Fix the cable flange with screws Z9 onto the cabled corner pillar A2 , and make sure the cable is hanging outside. Installation Video A2 Z9 x 4 Z9 x 4 A2 x 1 I x 1 12 1B I Slide the foot plate cover with its wide opening facing outwards on the straight end of the cabled corner pillar A2 . I A2 1C Push the foot plate J against the straight end of the cabled corner pillar A2 . It only fits in one direction and in one position. If in doubt, rotate it until it fits easily. Screw in the foot plate J with 6 screws O using a cordless screwdriver. O x 6 A2 J 1D x 3 Repeat steps 1B 1C to assemble the foot plates J of the 3 standard corner pillar A . O x 6 J x 1 I x 3 O x 18 J x 3 A x 3 A 13 2. Connect the side beam with motor B1 to the cabled corner pillar A2 and a regular corner pillar A 2A Pull out the cable at the end of the side beam with motor B1 through the small cut-out. B1 2B Using a hex key (large) Y , slightly loosen the 8 built-in screws at the both ends of the side beam with motor B1
(4 on each side). B1 x 1 Y x 1 B1 x 1 14 2C Lay two corner pillars ( A & A2 ) and place the side beam with gearbox B1 on the floor as shown in the picture. A2 x 1 B1 x 1 2D Slide beam with motor B1 into the grooves of the cabled corner pillar
( A & A2 ) in such a way that the slot nuts of the side beam with motor B1 interlock with the slots in the cabled corner pillar ( A & A2 ) . Warning:
Pull the cables out of the cabled corner pillar. Take care not to crush or squeeze the cables. A B1 A A2 B1 A2 15 2E Tighten the 8 screws ( 4 on each side) with the hex key Y . Y x 1 A B1 A2 3. Connect the side beam without motor B2 to the remaining two regular corner pillars A 3A Repeat steps 2A - 2E to connect the beam without motor B2 with the remaining two corner pillars A . A B2 Y x 1 B2 x 1 A x 2 16 4. Slide in the two end beams This phase requires four persons and at least two stepladders. Make sure that the stepladders are standing securely to avoid falling. Only use ladders suitable for this kind of installation work. 4 PEOPLE REQUIRED 4A m a e d b g t h n n e e le n o Gearbox n e p o Stand the two structures built during steps 2 and 3 in an upright position, and place them at one end beam length away from one another. Make sure that one person is supporting each corner leg ( A & A2 ) to prevent the structures from falling. Reminder:
When determining the installation direction of the product, please consider the opening direction of the louvers as well as the desired sunshade effect. 4B Slightly loosen the 8 built-in screws at both ends of the end beam C . Y x 1 C x 1 m a e d b g t h n n e e le n o x 8 17 4C C Slide the slot nuts of the end beams C from above into the slots of the corner pillars A . A A 4D Once the beam is in the correct position, tighten the 8 built-in screws on both ends using the hex key Y provided. 4E Install the other end beam C by repeating steps 4B - 4D . C x 1 Y x 1 Y x 1 C x 1 18 x 8 C A2 A 5. Install the LED strip lights READ AND FOLLOW ALL SAFETY INSTRUCTIONS Do not cover this product as the covering may cause the flexible light to overheat and melt or ignite. Do not operate with the flexible light tightly coiled. Do not puncture, cut, shorten, or splice the flexible lighting. Do not route the cord or flexible lighting through walls, doors, windows or any like part of the building structure. Do not use if there is any damage to the light or cord insulation. Inspect periodically. Do not submerge flexible light in liquids, or use the product in the vicinity of standing water or other liquids. Secure this flexible light using only the hangers or clips provided. Do not secure this product or its cord with staples, nails, or like means that may damage the insulation or permanently attach to the building structure. Do not subject flexible lighting to continuous flexing.
(For extendible units) Do Not Exceed The Length in Feet Permitted By The Marking. SAVE THESE INSTRUCTIONS 19 5A Z5 Place both LED light strips Z5 along the grooves on the side beams
( B1 & B2 ) and end beams C , as shown in the figure. Put the connection socket of the LED light strip Z5 close to the cabled corner pillar A2 , and put the end of the LED light strip Z5 into the top of the corresponding corner pillar if needed. B1 A2 Z5 B2 5B As shown in the figure, press both LED light strips Z5 firmly into the light strip slots one by one to ensure they are fitted evenly. Z5 x 2 Z5 x 2 20 Z5 Z5 6. Connect the power cables of the motor and LED strip lights Z5 5 pin 6A Connect the cable connector (5-pin) of the side beam with motor B1 into the corresponding connector socket on the top of the cabled corner pillar A2 . Then tighten the waterproof connector Connect the cable connector (4-pin) of the LED light strip Z5 into the corresponding connector socket on the top of the cabled corner pillar A2 . Then tighten the waterproof connector (there is no need to differentiate the plug sockets of the two light strips as they are the same). 4 pin Z5 x 2 Z8 x 1 B1 x 1 A2 x 1 Tip:
It is recommended to wrap waterproof adhesive tape on the waterproof connectors to prolong their service life. 5 pin B1 Z5 4 pin 21 6B Carefully tuck all connected cables and connectors at the top of the structure back into the corner pillar. 7. Check the alignment of the frame and the distance between the corner pillars You are now almost done installing the main frame of the pergola. Please double check to ensure all corner pillars, beams, and cables have been installed and fitted correctly. You may have to unscrew certain bolts during this step. You will also need a tape measure and a spirit level to complete this step. 7A Choose one of the corner pillars ( A &
A2 ) and work from this pillar. Choose this pillar carefully as it will define the final installation location of the pergola. Use a spirit level to measure against both of the inner sides to ensure that the corner pillar is straight and level. Make sure this corner pillar does not move position during the remaining installation steps. 22 Spirit level 7B Measure the distances between the adjacent corner pillars. Adjust accordingly and ensure the distances match those shown in the opposite figure. Size
(m) 3x3 a b
(mm)
(inch)
(mm)
(inch) 2790.4 109.9 2790.5 109.9 3x3.6 3400 133.9 2790.5 109.9 3x4 3705 145.9 2790.5 109.9 3.6x3.6 3400 133.9 3400 133.9 3.6x4 3705 145.9 3400 133.9 7C Measure the diagonal distance between the opposite corner pillars. Adjust the other corner pillars accordingly until both diagonal distances are equal. You may have to repeat the above steps after completing the remaining steps. Size
(m) 3x3 c
(mm)
(inch) 3951 155.6 3x3.6 4403 173.3 3x4 4643 182.8 3.6x3.6 4813 189.5 3.6x4 5033 198.1 b a a b c c 23
1 | User Manual rev1 part2 | Users Manual | 2.28 MiB | November 09 2023 / November 13 2023 |
Spirit level 7D Check that all corner pillars are straight and level using a spirit level. If the corner pillars or beams are still not level, this means that your main building surface isnt sufficiently level, and that you will need to raise the corner pillars that are positioned lower than the others. (Contact qualified workers if needed.) Warning:
If you do not adjust the main structure at this point, you may encounter problems when fitting the louvers and/or accessories to the frame. 24 8. Install the louvers, and connecting strip 8A Prepare the driving louver: select one of the louvers D to be the driving louver. Attach the louver end cap with control arm L to one end of the driving louver, and attach an louver end cap K to the other end of the driving louver. Use two screws Q on each side, and fix them firmly using a cordless screwdriver. D Q L x 1 K x 1 Q x 4 D x 1 L Q D K 25 K Q D K 8B Prepare the regular louvers: attach the louver end caps K to each end of the rest of the louvers D with two screws Q using a cordless screwdriver. Repeat this step for all louvers. D 3x3m 3x3.6m 3.6x3.6m 3x4m 3.6x4m Q K Q D 36 72 18 44 88 22 48 96 24 8C Place the louvers D on the corresponding louver shaft support on both side beams ( B1 & B2 ), with each louver overlapping the next, and make sure that the driving louver is placed 4th from the left. 26 4th Driving louver 8D Loosen the screw and washer already attached to the beam with motor. Then fix the connecting rod L of the driving louver to the side beam with motor B1 , by firmly tightening the same screw and washer, using the hexagon socket key X . L B1 X x 1 8E Secure the louvers D in the shaft support brackets by fixing a shaft support cover M onto the shaft support brackets on both ends of each louver D . Use two screws P each and secure them with a cordless screwdriver. Repeat this step for all louvers. 27 P G 3x3m 3x3.6m 3.6x3.6m 3x4m 3.6x4m 38 76 46 92 50 100 M P 8F Take the connecting strip G . Attach it to each louver fitting each of the holes onto the corresponding bolts of the louvers. Secure every bolt with a cotter pin S , inserting it through the small bolt hole. Repeat this step for all cotter pins. Reminder:
For the single louver model, the connecting strips are on both sides. M S 3x3m 3x3.6m 3.6x3.6m 3x4m 3.6x4m 1 19 1 23 1 25 G S 28 9. Finalize the electric connection and install the pillar cover 9A Install the 2.4G and 4G antenna Z7 , and make sure they correspond to the label on the side beam with motor B1 . B1 Z7 Z7 Z7 x 1 N x 4 R x 12 9B R To install the pillar cover, fix a pillar cover N to the top of each corner with three screws each R . Fix them using a cordless screwdriver. N Tip:
Check the frame alignment and pillar distances again by repeating 7A - 7D if necessary. x 4 29 2 pin 2 pin 9C Connect the cable on the base of the cabled corner pillar A2 to the cable of the power supply adapter Z4 . Tighten firmly. A2 Z4 x 1 Z8 x 1 Tip:
It is recommended to wrap waterproof adhesive tape on the waterproof connectors to prolong their service life. Z4 10. Pair the remote control 10A Insert the AAA batteries into the remote control Z6 . Z6 AAA batteries Z6 x 1 30 Z4 10B Plug the power supply adapter Z4 into the mains. Warning:
This product has a polarized plug
(one blade is wider than the other) as a feature to reduce the risk of electric shock. This plug will fit in a polarized outlet only one way. lf the plug does not fit fully in the outlet, reverse the plug. lf it still does not fit, contact a qualified electrician. Do not use with an extension cord unless plug can be fully inserted. Do not alter or replace the plug. This item may be omitted if the product does not employ a polarized plug. 10C Within 5 minutes, press and hold both 4 and 5 to pair the remote control Z6 . 4 5 Z4 x 1 Z6 x 1 Within the first 5 minutes of the gazebo being powered on, press and hold both open 1 and close 2 buttons for 3 seconds to pair the remote control with the gazebo. The LED light will then blink twice to indicate that the device has been successfully paired. For full remote control instructions, please see Light strip remote control guide. 31 11. Secure the corner pillars to the ground The pergola must be firmly and permanently secured to the ground. If the ground is not level or suitable, please refer to the section Before assembling your pergola. 11A x 4 To fix the corner pillars ( A & A2 ) with the four foot plates J , drill through each hole with a hammer drill. J x 4 Z x 1 11B x 4 Remove all the debris and dirt. Then firmly insert an anchor bolt W into each hole, using a hammer. W x 16 10A x 4 Tighten the hexagonal ends of each bolt with a spanner/wrench. 32 J W 12. End of installation 33 OPERATION OF YOUR MIRADOR PERGOLA How to use the remote control 1 2 3 4 5 6 7 8 9 10 Pairing I. Insert 2 AAA batteries into the remote control II. Plug the power adapter of the pergola into a socket III. Within the first 5 minutes of the pergola being powered on, press and hold both open 4 and close 5 buttons for 3 seconds to pair the remote control with the pergola.
(Once paired, all louvers will move back and forth once to indicate success.) Operating 1 Toggle to control actuactor 1, actuactor 2 or both actuactors 2 Led indicator for actuactor 1 3 Led indicator for actuactor 2 4 Open louvers 5 Close louvers 6 Stop louver movement 7 Single color mode: Toggle light colors 8 Dynamic lighting mode: Toggle chasing effects 9 Adjust brightness (Only works for single color mode) 10 Turn on/off lights Notice How to connect the product with your phone If you own a single pergola instead of a dual-pergola set, make sure only led indicator 2 is on. If you have problem paring or controlling the pergola Stand closer to the pergola I. Download the Mirador app from Google Play Store or App Make sure to point the remote control directly at the pergola Store by scanning the QR code below Make sure batteries are not worn out and that they are inserted correctly II. Open the Mirador app and scan the QR code on the nameplate on the beam to pair the pergola Try pairing again the remote control by unplug the pergola first and follow the pairing steps Warning Non-rechargeable batteries are not to be recharged. Different types of batteries are not to be mixed. New and used batteries are not to be mixed. Batteries are to be inserted with the correct polarity. Exhausted batteries are to be removed from the appliance and safely disposed of. If the appliance is to be stored unused for a long period, the batteries should be removed. Please refer to the problem solving section on page 35 if you run into any issues. The supply terminals are not to be short-circuited. 34 PROBLEM SOLVING, CARE & MAINTENANCE Issue Explanation or action to take The LED light strip is deformed after removing it from the packaging. Expand the light strip and leave it at room temperature for a period of time until its shape is restored before installing it. The surface of the LED light strip oxidizes and changes color after long-term use. Regularly clean the surface to ensure cleanliness. If necessary, order a replacement light strip. Abnormal noise occurs during the rotation of the louver(s). The remote control cannot be paired with the control system. The remote control can be paired with the control system, but the app cannot. Check if any of the louvers are deformed. If this is the case, replace them. If the louvers are not deformed but they are colliding with one another, replace the beam. Check if the product is powered on. Check if the remote control battery is installed or if the battery is depleted. Remove the rear cover of the remote control and check if the positive and negative poles of the battery are correct. Remove the battery and reinstall it to avoid poor contact. (The details can be reviewed in the Page34) If the problem still persists, please contact customer service. It may take a few minutes for the device to search for the network. Please enter the network configuration diagnostic mode. Then wait patiently and confirm that the light strip flashes blue before attempting to scan the code for pairing. If there are still problems, please contact point of sale. The LED light strip operates normally, but the liner actuator does not. Replace the beam with motor. During operation, the product takes time to respond, or the app does not operate in real-time. Check the local network signal strength. The product is a dual-pergola, and the louvers on both sides do not open or close synchronously. Slight asynchronization is normal. If it differs by more than 1 second, please refer to the contact section on page 38. 35 Issue Explanation or action to take Some of the light beads on the LED light strip do not work according to the instructions. Replace the light strip. The flatness of the louver is damaged due to weather conditions. Replace the affected louvers. The louvers cannot be reset when there is a power failure. Remove the screws on the driver, take out the driver connected to the screws, and allow the louvers to reset automatically. The drain is blocked by leaves or debris. Clean the ducts and guttering of the pergola regularly. The casting powder on the beam surface falls off after the motor runs for long periods. No intervention is needed under normal circumstances. How do I enter the network configuration diagnostic mode?
Connect the device to the mains and ensure that the light strip is turned off. Then, simultaneously press and hold the increase brightness + and decrease brightness - keys. The light strip in the device's corner will blink in different colors to indicate the current network status. SIM card not detected IP Obtained Searching for Service Connected to the Cloud Registered Successfully SIM Card Registration Denied General Care & Maintenance Dust and dirt will collect on the pergola and will require periodic cleaning Use a water/detergent mixture and a soft clean cloth to clean the pergola. Air dry or wipe with a soft clean cloth Do not operate the awning when maintenance, such as window cleaning, is being carried out in the vicinity. 36 For more soiled areas, rinse the surface with clean water from top to bottom. In most situations it is not necessary to lubricate the moving parts of the pergola. However, when squeaking occurs, using a silicone spray lubricant is recommended. Do not use any petroleum based spray lubricant. Disconnect the awning from the supply when maintenance, such as window cleaning, is being carried out in the vicinity. Silicone based Petroleum based In coastal areas, it is recommended that you frequently spray the pergola with water to reduce accumulation of salt and dirt. Disconnect the cables if the pergola is not being used for long periods. When the temperature is below 0C/32F , it is recommended to use the product less frequently to prolong the product's service life. The drive shall be disconnected from its power source during cleaning, maintenance and when replacing parts.
< 0C / 32F Periodic inspection Frequently examine the installation for imbalance and signs of wear ordamage to cables and springs. Do not use if repair or adjustment isnecessary. Check the pergola is fixed firmly to the ground. Check the pergolas mobile components are in good working order, Check that the driving parts are sufficiently lubricated, Check the condition of the electrical cables and inspect their mains connection. Check the operation of the motors limit switch and correct where necessary. Check the screws and rivet joints on the pergola. Check of the condition of mobile roof and bearings. 37 WARRANTY &
COMPLAINTS PROCEDURE For terms and conditions of our limited warranty, please visit www.miradoroutdoor.com or contact your local Mirador sales representative. Complaints procedure:
The complaint must include an order number or transaction number. Goods without an order number or transaction number are not covered under the warranty. The complaint must include a detailed description of the defect, the name of the company which installed the product and the date when the defect was discovered. At Sorara outdoor Living USA's discretion, customer must offer supplier the photos/videos of the issue/damaged parts. Otherwise, supplier reserves the right to refuse replacement parts or credit. Please save a copy of your purchase receipt. Contact:
USA: support@miradoroutdoor.com 1-800-867-9018from Mon-Fri 8:30AM-4:30 PM PST Other areas: Please contact the point of sale 38 DISASSEMBLY AND DISPOSAL OF THE PRODUCT Incorrect disassembly of the pergola may lead to serious injury and product damage. Disassembly should be assigned to qualified personnel with adequate training within the scope of occupational health and safety and knowledge within the scope of recycling. Disposal of used Electrical and Electronic Equipment When the service life of the product is over, it is necessary to disassemble it for disposal and to sort the individual materials and components in compliance with the local regulations of your country. Important disposal information In compliance with European Directive 2012/19EU on waste electrical and electronic equipment (WEEE) is it forbidden to place the waste equipment marked with the crossed bin symbol with other waste to a container intended for domestic waste. Users wishing to dispose of electronic or electrical equipment are obliged to return it to a designated waste equipment collection point. The above statutory obligations were introduced in order to limit the amount of waste generated from waste electrical and electronic equipment, and to ensure an appropriate level of collection, recovery and recycling. The equipment does not contain hazardous components which have a particularly adverse effect on the environment or human health. Utilization of used batteries In compliance with the provisions of the Directive 2006/66/EC of the European Parliament and of the Council of 6 September 2006 on batteries and accumulators and waste batteries and accumulators and repealing Directive 91/157/EEC, the End User is obliged to transfer used portable batteries, which are no longer used as a source of energy, to an official collection point. It is forbidden to place used batteries with other waste in the same container. To prevent environmental pollution and causing a possible hazard for human and animal health, used batteries should be disposed of in the correct container at the designated collection points. 39 CERTIFICATION INFORMATION
- Declaration of performance (DOP)
- EU Declaration of Conformity
- EC Declaration of Conformity
- UK Declaration of Conformity
- ETL
- FCC 40 41 42 43 44 45 46 Declaration of performance (DOP) Reference no. DOP0001 Product name and type Mirador Pergola and Mirador Wall Pergola/ pergola awning Model name/ Unique identification code of the product:
111 Deluxe AxBm, 111 Deluxe e AxBm, 111 Deluxe e-Motion RC AxBm, 111 Deluxe e-Motion AxBm, 111 DA AxBm, 111 LED DA AxBm, 111 e-Motion DA AxBm, 111 e-Motion+ AxBm, 111 Deluxe Edge AxBm, 111 Deluxe Edge e AxBm, 111 Deluxe Edge e-Motion RC AxBm, 111 Deluxe Edge e-Motion AxBm, 111 Deluxe R AxBm, 111 Deluxe R e AxBm, 111 Deluxe R e-Motion RC AxBm, 111 Deluxe R e-Motion AxBm, AxB:
3x3, 3x3.6, 3x4, 3.6x3.6, 3.6x4, 3x5.3, 3x6, 3x7.2, 3.6x5.3, 3.6x6, 3.6x7.2 111 Classic AxBm, 111 Classic e AxBm, 111 Classic e-Motion AxBm, 111 S AxBm, 111 LED S AxBm, 111 e-Motion S AxBm, 111 Premium AxBm, 111 Premium e AxBm, 111 Premium e-Motion AxBm, 111 A AxBm, 111 LED A AxBm, 111 e-Motion A AxBm, AxB:
3x3, 3x3.6, 3x4, 3x5.3, 3x6, 3x7.2 111 Infinite AxBm, 111 Infinite e AxBm, 111 Infinite e-Motion RC AxBm, 111 Infinite e-Motion AxBm, 111 Infinite LED AxBm, 111 Infinite e-Motion DA AxBm, 111 Infinite e-Motion+ AxBm, 111 Infinite Edge AxBm, 111 Infinite Edge e AxBm, 111 Infinite Edge e-Motion RC AxBm, 111 Infinite e-Motion AxBm, AxB:
3x3, 3x3.6, 3x4, 3x5.3, 3x6, 3x7.2, 3.6x3.6, 3.6x4, 3.6x5.3, 3.6x6, 3.6x7.2, 7.2x7.2 Purpose of Usage:
External use in buildings and other construction works Manufacturer:
Zhejiang Zhengte Co., Ltd. 811 Dongfang Ave, Zhejiang, PRC Documentation officer:
Stefan Baricik Sorara Outdoor Living B.V. Cockeveld 3, 5672 AE Nuenen, The Netherlands System for assessing and verifying the constancy of performance according to Annex V of the Construction Products Directive 305/2011/EC System 4 Declared performance (Excluding the structural part):
Wind resistance = Class 6 Standard: EN 13561:2004+A1:2008 Zhejiang 20.07.23 41 EU Declaration of Conformity Product name Mirador Pergola Model name/ Unique identification code of the product:
111 Deluxe e-Motion RC 3x7.2m, 111 Deluxe e-Motion RC 3.6x3.6m, 111 Deluxe e-Motion RC 3.6x4m, 111 Deluxe e-Motion RC 3.6x5.3m, 111 Deluxe e-Motion RC 3.6x6m, 111 Deluxe e-Motion RC 3.6x7.2m 111 Deluxe e-Motion 3x3m, 111 Deluxe e-Motion 3x3.6m, 111 Deluxe e-Motion 3x4m, 111 Deluxe e-Motion 3x5.3m, 111 Deluxe e-Motion 3x6m, 111 Deluxe e-Motion 3x7.2m, 111 Deluxe e-Motion 3.6x3.6m, 111 Deluxe e-Motion 3.6x4m, 111 Deluxe e-Motion 3.6x5.3m, 111 Deluxe e-Motion 3.6x6m, 111 Deluxe e-Motion 3.6x7.2m, 111 Deluxe Edge e-Motion 3x3m, 111 Deluxe Edge e-Motion 3x3.6m, 111 Deluxe Edge e-Motion 3x4m, 111 Deluxe Edge e-Motion 3x5.3m, 111 Deluxe Edge e-Motion 3x6m, 111 Deluxe Edge e-Motion 3x7.2m, 111 Deluxe Edge e-Motion 3.6x3.6m, 111 Deluxe Edge e-Motion 3.6x4m, 111 Deluxe Edge e-Motion 3.6x5.3m, 111 Deluxe Edge e-Motion 3.6x6m, 111 Deluxe Edge e-Motion 3.6x7.2m, 111 Deluxe R e-Motion 3x3m, 111 Deluxe R e-Motion 3x3.6m, 111 Deluxe R e-Motion 3x4m, 111 Deluxe R e-Motion 3x5.3m, 111 Deluxe R e-Motion 3x6m, 111 Deluxe R e-Motion 3x7.2m, 111 Deluxe R e-Motion 3.6x3.6m, 111 Deluxe R e-Motion 3.6x4m, 111 Deluxe R e-Motion 3.6x5.3m, 111 Deluxe R e-Motion 3.6x6m, 111 Deluxe R e-Motion 3.6x7.2m 111 Infinite e-Motion 3x3m, 111 Infinite e-Motion 3x3.6m, 111 Infinite e-Motion 3x4m, 111 Infinite e-Motion 3x5.3m, 111 Infinite e-Motion 3x6m, 111 Infinite e-Motion 3x7.2m, 111 Infinite e-Motion 3.6x3.6m, 111 Infinite e-Motion 3.6x4m, 111 Infinite e-Motion 3.6x5.3m, 111 Infinite e-Motion 3.6x6m, 111 Infinite e-Motion 3.6x7.2m, 111 Infinite Edge e-Motion 3x3m, 111 Infinite Edge e-Motion 3x3.6m, 111 Infinite Edge e-Motion 3x4m, 111 Infinite Edge e-Motion 3x5.3m, 111 Infinite Edge e-Motion 3x6m, 111 Infinite Edge e-Motion 3x7.2m, 111 Infinite Edge e-Motion 3.6x3.6m, 111 Infinite Edge e-Motion 3.6x4m, 111 Infinite Edge e-Motion 3.6x5.3m, 111 Infinite Edge e-Motion 3.6x6m, 111 Infinite Edge e-Motion 3.6x7.2m 111 Classic e-Motion 3x3m, 111 Classic e-Motion 3x3.6m, 111 Classic e-Motion 3x4m, 111 Classic e-Motion 3x5.3m, 111 Classic e-Motion 3x6m, 111 Classic e-Motion 3x7.2m Software: ZTC1_EU_M2_Boot_Main Accessories: Remote control, 3V DC Battery Purpose of Usage:
External use in buildings and other construction works Manufacturer:
Zhejiang Zhengte Co., Ltd. No. 588 Linhai Ave., 317000 Linhai, Zhejiang, PRC Documentation officer:
Stefan Baricik Sorara Outdoor Living B.V. Cockeveld 3, 5672 AE Nuenen, The Netherlands Meets the provisions of Machinery Directive 2006/42/EC Harmonised standards used:
EN 13561:2015, EN 60335-1:2012+A11:2014+A13:2017+A1:2019 + A14:2019 +A2:2019+A15:2021, EN 60335-2-97:2006+A11:2008+ A2:2010+ A12:2015, EN 62233:2008, EN IEC 55014-1:2021, EN IEC 55014-2:2021 EN IEC 55015:2019/A11:2020, EN 61547:2009, EN IEC 61000-3-2:2019/A1:2021, EN 61000-3-3:2013/A2:2021, EN 301 489-1 V2.2.3:2019, EN 301 489-3 V2.3.2:2023, EN 301 489-52 V1.2.1:2021, EN 300 440 V2.1.1, EN 300 440 V2.2.1, EN 301 908-1 V15.1.1, EN 301 908-13 V13.2.1, EN 50663:2017, EN 62311:2008, EN 50665:2017 Notified Body: TV SD Danmark ApS NB No.: 2443 Certificate No.: DK-RED002818 i01, DK-RED002821 i01 Zhejiang 28.09.23 42
(Chairman/President) EC Declaration of Conformity Product name and type Mirador Pergola and Mirador Wall Pergola/ pergola awning Model name/ Unique identification code of the product:
111 Deluxe AxBm, 111 Deluxe e AxBm, 111 Deluxe e-Motion RC AxBm, 111 Deluxe e-Motion AxBm 111 Deluxe Edge AxBm, 111 Deluxe Edge e AxBm, 111 Deluxe Edge e-Motion RC AxBm, 111 Deluxe Edge e-Motion AxBm 111 Deluxe R AxBm, 111 Deluxe R e AxBm, 111 Deluxe R e-Motion RC AxBm, 111 Deluxe R e-Motion AxBm AxB:
3x3, 3x3.6, 3x4, 3.6x3.6, 3.6x4, 3x5.3, 3x6, 3x7.2, 3.6x5.3, 3.6x6, 3.6x7.2 111 Classic AxBm, 111 Classic e AxBm, 111 Classic e-Motion AxBm 111 Premium AxBm, 111 Premium e AxBm, 111 Premium e-Motion AxBm, AxB:
3x3, 3x3.6, 3x4, 3x5.3, 3x6, 3x7.2 111 Infinite AxBm, 111 Infinite e AxBm, 111 Infinite e-Motion RC AxBm, 111 Infinite e-Motion AxBm AxB:
3.6x3.6, 7.2x7.2 Purpose of Usage:
External use in buildings and other construction works Manufacturer:
Zhejiang Zhengte Co., Ltd. 811 Dongfang Ave, Zhejiang (China) Documentation officer:
Stefan Baricik Sorara Outdoor Living B.V. Cockeveld 3, 5672 AE Nuenen (The Netherlands) Meets the provisions of Machinery Directive 2006/42/EC Harmonised standards used:
EN 13561:2015 EN 60335-1:2012+A11:2014+A13:2017+A1:2019 + A14:2019 +A2:2019+A15:2021 EN 60335-2-97:2006+A11:2008+ A2:2010+ A12:2015 EN 62233:2008 Zhejiang 20.07.23 43 UK Declaration of Conformity Product name and type Mirador Pergola Model name/ Unique identification code of the product:
111 Deluxe AxBm, 111 Deluxe e AxBm, 111 Deluxe e-Motion RC AxBm, 111 Deluxe e-Motion AxBm 111 Deluxe Edge AxBm, 111 Deluxe Edge e AxBm, 111 Deluxe Edge e-Motion RC AxBm, 111 Deluxe Edge e-Motion AxBm 111 Deluxe R AxBm, 111 Deluxe R e AxBm, 111 Deluxe R e-Motion RC AxBm, 111 Deluxe R e-Motion AxBm AxB:
3x3, 3x3.6, 3x4, 3.6x3.6, 3.6x4, 3x5.3, 3x6, 3x7.2, 3.6x5.3, 3.6x6, 3.6x7.2 111 Classic AxBm, 111 Classic e AxBm, 111 Classic e-Motion AxBm 111 Premium AxBm, 111 Premium e AxBm, 111 Premium e-Motion AxBm, AxB:
3x3, 3x3.6, 3x4, 3x5.3, 3x6, 3x7.2 111 Infinite AxBm, 111 Infinite e AxBm, 111 Infinite e-Motion RC AxBm, 111 Infinite e-Motion AxBm AxB:
3.6x3.6, 7.2x7.2 Purpose of Usage:
External use in buildings and other construction works Manufacturer:
Zhejiang Zhengte Co., Ltd. 811 Dongfang Ave, Zhejiang (China) Documentation officer:
Stefan Baricik Sorara Outdoor Living B.V. Cockeveld 3, 5672 AE Nuenen (The Netherlands) Meets the provisions of Supply of Machinery (Safety) Regulations 2008 (No. 1597) Harmonised standards used:
EN 13561:2015 EN 60335-1:2012 EN 60335-1:2012/AC:2014 EN 60335-1:2012/A11:2014 EN 60335-1:2012/A13:2017 EN 60335-1:2012/A15:2021 EN 60335-2-97:2006 EN 60335-2-97:2006/A12:2015 Zhejiang 20.07.23 44 CERTIFICATION INFORMATION ETL LISTED MARK Conforms to the standard Door, Drapery, Gate, Louver, and Window Operators and Systems
[ANSI/CAN/UL 325:2017 Ed.7+R:28Feb2020]
ETL is a Certification Program provided by Intertek, which is a Recognized Testing Laboratory (NRTL) in the United 5026666 States, and is accredited by institutes and associations such as ANSI, A2LA, and UKAS. The Mirador 111 DA e-Motion+ is ETL certified in the United States of America under Control Number 5026666 45 FCC INFORMATION Supplier's Declaration of Conformity Compliance Information Unique Identifier Product Description Model Number Trade Name FCC Compliance Statement Electrical pergola 111 DA e-Motion+
Mirador This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Responsible Party - U.S. Contact Information Company:
Address:
Sorara Outdoor Living USA, Inc. 15271 Fairfield Ranch Rd. , Ste# 180, Chino Hills, CA 91709 Telephone or internet contact information:
1-800-867-9018 Hello@Sorara.com Warning: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. For Pergola:
MPE Requirements To satisfy FCC RF exposure requirements, a separation distance of 20 cm or more should be maintained between the antenna of this device and persons during device operation. To ensure compliance, operations at closer than this distance is not recommended. For remote control:
This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter. 46 111 DA e-Motion+
1 | Label and Location | ID Label/Location Info | 1.47 MiB | November 09 2023 / November 13 2023 |
_ZTH1_ 41.5mm x 59mm 59mm Pair the remote control Insert batteries into the remote control Plug your pergola into a power socket Within 5 minutes, press and hold both and to pair the remote control All louvers will move back and forth once to indicate successful pairing PLEASE UNPLUG AND REPEAT THE PAIRING PROCESS IF YOU MISS THE 5-MINUTE TIME WINDOW. Connect your phone Download the Mirador app from Google Play Store or App Store Make sure your pergola is plugged in Open the Mirador app and scan the QR code on the beam to connect PLEASE RESCAN THE QR CODE OR REFEAR TO THE MANUAL IF YOU ENCOUNTER ANY ISSUES. Model No: ZTH1 FCC ID: 2BAQKZTPG0001 41.5mm Pair the remote control Insert batteries into the remote control Plug your pergola into a power socket Within 5 minutes, press and hold both and to pair the remote control All louvers will move back and forth once to indicate successful pairing PLEASE UNPLUG AND REPEAT THE PAIRING PROCESS IF YOU MISS THE 5-MINUTE TIME WINDOW. Connect your phone Download the Mirador app from Google Play Store or App Store Make sure your pergola is plugged in Open the Mirador app and scan the QR code on the beam to connect PLEASE RESCAN THE QR CODE OR REFEAR TO THE MANUAL IF YOU ENCOUNTER ANY ISSUES. Model No: ZTH1 FCC ID: 2BAQKZTPG0001 R1 Arial Bold Italic7pt Arial Regular6pt Arial Narrow Italic7pt Arial Bold Italic6pt
1 | 230101492SHA-001 Test Report rev1 | Test Report | 676.22 KiB | November 09 2023 / November 13 2023 |
1 | 230101492SHA-002 Report FCC SAR Test Exclusion | RF Exposure Info | 391.28 KiB | November 09 2023 / November 13 2023 |
1 | ACB-Covered-List-Attestation | Attestation Statements | 140.94 KiB | November 09 2023 / November 13 2023 |
ZHEJIANG ZHENGTE CO.,LTD. Certification Application Attestation Statements Date: November 1, 2023 American Certification Body, Inc. 313 Park Avenue Suite 300 Falls Church, VA 22046 To Whom It May Concern:
Statement for 47 CFR section 2.911(d)(5)(i) ZHEJIANG ZHENGTE CO.,LTD._ certifies that as of the date of the application the equipment for which authorization is sought is not covered equipment1 prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, including affiliates or subsidiaries of the named companies, the applicant must include an explanation on why the equipment is not covered equipment. Additional Explanation: <N/A>
Statement for 47 CFR section 2.911(d)(5)(ii) ZHEJIANG ZHENGTE CO.,LTD._ (the applicant) certifies that, as of the date of the filing of this application, the applicant - is / - is not identified on the Covered List as an entity producing covered equipment. Thank you, By:
___ ______ ________Leo zhou________ Title:
____Senior Engineer___ Company:
__ZHEJIANG ZHENGTE CO.,LTD.___ Telephone:
___18989785133_____ 1 - The Commissions Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commissions website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes covered equipment. https://www.fcc.gov/supplychain/coveredlist . 022423-17 rev 6
1 | ACB-FCC-Agency-Letter | Cover Letter(s) | 46.27 KiB | November 09 2023 / November 13 2023 |
ZHEJIANG ZHENGTE CO.,LTD. Authority to Act as Agent Date: November 1, 2023 American Certification Body, Inc. 313 Park Avenue Suite 300 Falls Church, VA 22046 To Whom It May Concern:
______Intertek Testing Service Shanghai______ is authorized to act on our behalf, until otherwise notified, for applications to American Certification Body, Inc. (ACB). We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. We also declare that the information provided to the FCC is true and correct to the best of our knowledge (47 CFR 2.911(d)) and we have been informed of the grantee responsibilities (47 CFR 2.909) with regard to certified equipment. Thank you, Agency Agreement Expiration Date: ___2023/12/31___ By:
___ _____ ______Leo zhou_____ Title:
_____ Senior Engineer ____ On behalf of: ___ZHEJIANG ZHENGTE CO.,LTD.____ Telephone:
_______18989785133____________________ 050222-17
1 | ACB-FCC-Confidentiality-Letter | Cover Letter(s) | 105.85 KiB | November 09 2023 / November 13 2023 |
ZHEJIANG ZHENGTE CO.,LTD. Request for Confidentiality Date: November 1, 2023 Subject: Confidentiality Request for: ______ 2BAQKZTPG0001______ Pursuant to FCC 47 CFR 0.457(d) and 0.459 and/or IC RSP-100, Section 12.4, the applicant requests that a part of the subject application(s) be held confidential. Type of Confidentiality Requested Short Term Short Term Short Term Short Term Short Term Short Term Short Term Short Term Short Term Exhibit Permanent Block Diagrams
--------------------------- External Photos Permanent *1 Internal Photos Permanent Operation Description/Theory of Operation Permanent Parts List & Placement/BOM Permanent Tune-Up Procedure Permanent Schematics
--------------------------- Test Setup Photos Permanent *1 Users Manual _ ZHEJIANG ZHENGTE CO.,LTD.__ has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality:
The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality for FCC Applications:
The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of __ (specify number of days not to exceed 180)2___ days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify ACB in the event information regarding the product or the product is made available to the public before the requested period has expired. ACB will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. Short Term Confidentiality for Industry Canada Applications:
Starting May 2022, ISED will recognize short term confidentiality on certain exhibits until the intended date of marketing. The applicant requests the exhibits selected above as short term confidential be withheld from public view until: (specify ISED expiration date / date of marketing) . Sincerely, By:
(Signature/Title3) Senior Engineer_ _______Leo zhou____________ 1 - The asterisked items (*) require further information to be provided to ACB before permanent confidentiality will be extended to these exhibits. Please refer to FCC KDB 726920 and the specific Document link for D01 found at:
https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=41731 and review section II, 3) regarding specific information that must accompany these requests. 2 - Please refer to https://acbcert.com/documents/misc-docs/Memo-Short-Term-Vs-Standard-Confidentiality.pdf for complete details. 3 - Must be signed by applicant contact given for applicant on the FCC site, or by the authorized agent if an appropriate authorized agent letter has been provided. Letters should be placed on appropriate letterhead. 050222-17
1 | ACB-U.S.-Agent-Letter rev1 | Attestation Statements | 152.36 KiB | November 09 2023 / November 13 2023 |
U.S. Agent Designation for Service of Process
(Applicant and U.S. Agent are Separate Parties) TO: American Certification Body, Inc. 313 Park Avenue Suite 300 Falls Church, VA 22046 ATTENTION: FCC Certification Section 2.911(d)(7) Information Designated U.S. Agent Company Name: RQ&T Inc Contact Name: Will Zhang Street Address: 1020 S EASTHILLS DR WEST COVINA CA 91791 City/Province/Zip: CA 91791 Telephone No: +626 3715766 Email: willz@rqtusa.com FRN #: 0033406182 This letter is to confirm that we (the Designated U.S. Agent) have accepted the responsibility to act as the Designated U.S. Agent for Service of Process as required by section 47 CFR 2.911(d)(7) on behalf of the Applicant noted below. U.S. Agent Signature:
Date: 09.13 2023 Signed by (Printed Name/Title): Will Zhang / Regulation Manager The Applicant acknowledges that they must maintain an agent for no less than one year after terminating all marketing and importation OR the conclusion of any Commission-related proceeding involving the equipment. The applicant further acknowledges their responsibility to inform the FCC whenever the Designated U.S. Agent information above changes. Applicant Company name: ZHEJIANG ZHENGTE CO.,LTD. Grantee Code: 2BAQK FRN #: 0033601824 Contact Name: Leo Zhou Street Address: No.811, Oriental Ave., Linhai, 317004, Zhejiang, China City/Province/Zip: Linhai/317004 Telephone No: +86-18989785133 Email: leo@zhengte.com.cn Applicant Signature1:
Date: September 13, 2023 Signed by (Printed Name/Title): Leo Zhou/ Senior Manager
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2023-11-13 | 2430 ~ 2437 | DXX - Part 15 Low Power Communication Device Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2023-11-13
|
||||
1 | Applicant's complete, legal business name |
ZHEJIANG ZHENGTE CO.,LTD.
|
||||
1 | FCC Registration Number (FRN) |
0033601824
|
||||
1 | Physical Address |
No.811, Oriental Ave., Linhai, 317004, Zhejiang, China
|
||||
1 |
No.811, Oriental Ave., Linhai, 317004
|
|||||
1 |
Linhai, N/A
|
|||||
1 |
China
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
h******@acbcert.com
|
||||
1 | TCB Scope |
A2: Low Power Transmitters (except Spread Spectrum) and radar detectors operating above 1 GHz
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
2BAQK
|
||||
1 | Equipment Product Code |
ZTPG0001
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
L******** z******
|
||||
1 | Telephone Number |
18989********
|
||||
1 | Fax Number |
18989********
|
||||
1 |
l******@zhengte.com.cn
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
Intertek Testing Services Limited Shanghai
|
||||
1 | Name |
S**** Y********
|
||||
1 | Physical Address |
Building No.86, 1198 Qinzhou Road(North)
|
||||
1 |
Shanghai, 200233
|
|||||
1 |
China
|
|||||
1 | Telephone Number |
+8621********
|
||||
1 |
s******@intertek.com
|
|||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DXX - Part 15 Low Power Communication Device Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | ZTH1 | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Intertek Testing Services Shanghai
|
||||
1 | Name |
L****** X******
|
||||
1 | Telephone Number |
+86 2********
|
||||
1 |
l******@intertek.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 2430.00000000 | 2437.00000000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC