TA1102 / Product Specifications TA1102 Bluetooth Heart Rate Monitor Heart rate monitor (HRM) Bluetooth transmission LED light display Sound alarm Product Specifications Heart Rate Accuracy 1 BPM Heart Rate Range 30 to 240 BPM Sampling Rate 250 Hz Switch Power Switch (ON/OFF) Charging Connection Micro USB Battery Charge Time 1 hr to 90%, 3 hrs to 100% (full charged) Size (L W H) 61 mm 43.1 mm 16.1 mm Weight 22 g Battery Type Rechargeable Li-Polymer Battery
(Nominal Voltage: 3.7 V) *Note 1. Transmission Range Up to 10 m / 30 ft Transmission Frequency 2.4 GHz Wireless Technology Bluetooth Version 3.0 + EDR Battery Life *Note 2.
( Heart Rate Mode)
( Raw Data Mode) 20+ hrs 10+ hrs Operating Temperature 0C to +50C / +32F to +122F Sound
- Power ON
- Power OFF
- Low Battery Alarm Notes:
1.Battery Charging: Built-in Li-polymer cell, rechargeable via any USB port or with any USB-compliant adapter. 2. Heart Rate Mode: Average heart rate Raw Data Mode: Heart beat wave form
(Charging Connection: using Micro USB to USB cable) HRM Belt / Product Specifications HRM Belt Textile approach gives a natural platform for measuring heart rate Comfort belt sensor technology is based on polymer material This is the most flexible and lightweight belt Product Specifications Color Size (L W) Black 880 mm 30 mm Distance between snaps from center to center 45.5 mm Conductivity
(measured between electrical skin contact and a snap) In production: < 2.5 k After 100 washes: < 5 k Storage Temperature 0C to +40C / +32F to +104F Storage Humidity Machine Wash 20% to 98%
delicate at +40C / +104F Care and Maintenance Instructions HRM Belt / Care and Maintenance Storage Conditions Storage temperature and humidity :
Temperature 0C to +40C, Humidity 20% to 98% (RH) Inadequate storage conditions may cause product deterioration. Product should be stored away from light and heat. All the characteristics mentioned in specification remain as specified when stored in suitable conditions. Care and Washing Following of the given care instruction will ensure longer product lifetime. The HRM belt can be washed with most common laundry detergents. Use of detergents with optical brightening agents, detergents with bleaching agents, soap or fabric softener is not recommend. The belt does not resist soaking, dry-cleaning or bleaching. The HRM belt should be dry flat, hang dry or drip dry. Belt does not resist tumble drying and should not be wring dry. Wet belt should not be stretch unnecessarily. Ironing and pressing with heat are forbidden. Care symbols for HRM belt. How to Wear & Connect HRM Belt TA1102 Wear & Connect Before You Begin 1. Download the HRM-compatible smartphone App. 2. Charge the device battery for 1 full hour to start. 1. Adjust 2. Attach 3. Position Putting on Your HRM Belt Wet the electrode areas of the belt under running water. 1. Tie the belt around the chest and adjust the belt length to fit to the body. 2. Attach the HRM device to the belt. 3. Position the device below the middle of the chest. For women, the belt positioned below the bra. Check that the electrode areas are firmly against your skin and ensure the belt is centered on your chest. Connect with the Smart Phone App During paring, please keep least 20 meters away form other compatible HRM device, prevent interfering stray signals. 1. Setting General Bluetooth ON paring with the HRM device 2. Enter the PIN code: 0000 3. Active the smartphone mobile App and start workout General Guidance TA1102 / Bluetooth HRM Device Turn-on and Turn-off Turn-on Press power button for 3 seconds to turn-on the device turn-on sound (rising) and LED flash for 5 seconds HRM device is active Turn-off Press power button for 3 seconds to turn-off the device turn-off sound (falling) Indicator Light Heart Rate Mode : RED light blink slowly (If the heart beat faster, then RED light blinking faster) Raw Data Mode : no light indication Battery Charging State : RED light on (consistently); Light Off charging completed Low Battery Alarm: RED light flashing regularly, and the sound alarmed once a minute Charging the Battery To charge the battery, connect to a computer or AC adapter with the Micro USB to Standard USB cable. Care & Maintenance Store your device in a clean and dry environment at room temperature. Do not place the device where it could be scratched by hard objects. Do not use cleaning solvents, acetone, alcohol, insect repellents, paint, or other strong chemicals cleaners. Failure of the HRM Connection Troubleshooting The heart rate monitor device uses high frequency transmission to prevent reading disturbances. However, users near overhead power lines or magnetic or electronic devices may cause interference with the signal. If you lose the signal, please double check the following:
Check HRM device battery capacity. Make sure you are wearing the belt correctly. Make sure the electrode areas is wet. Check that the electrode areas of the belt are touch with your skin Check that the HRM device snap to the belt and position correctly. Make sure your device are not near (40 meters) other Bluetooth compatible devices, which could affect pairing. Move away from any potential sources of interference, such as microwave, motor, high voltage line, and Wi-Fi AP. If fail in connectivity with HRM device, please restart the device/ smartphones App for reconnection. Precautions-I Precautions The HRM is designed to help you achieve personal fitness goals and fitness training intensity. Please be noticed that physical training may include some risk. Before beginning a regular training program, answer the following questions concerning your health status. To Consult a physician before starting any training program if you answer yes to any following questions. 1. Do you have high blood pressure or high blood cholesterol?
2. Do you have symptoms of any disease?
3. 4. Do you have a history of breathing problems?
5. Are you recovering form a serious illness or medical treatment?
6. Do you use a pacemaker or other implanted electronic device?
7. Do you smoke?
8. Are you taking any blood pressure or heart medication?
Are you pregnant?
Precautions-II Precautions Note that in addition to training intensity, medication for heart conditions/blood pressure/psychological conditions/asthma/breathing/etc. as well as some energy drinks, alcohol, and nicotine may also affect heart rate. It is important to be sensitive to your bodys responses during the training. If you feel unexpected pain or excessive fatigue when training, stop the exercise or continue at a lighter intensity. If you have a pacemaker, defibrillator or other implanted electronic device, you use the HRM device at your own risk. Before starting use, take a maximal training stress test under the supervision of physician. The test is to ensure the safety and reliability of the simultaneous use of the pacemaker and the HRM device. Qualification & Certification Qualification & Certification FCC ID : B5OIWT11 Attention Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC/IC Radio Frequency Exposure The available scientific evidence does not show that any health problems are associated with using low power wireless devices. There is no proof, however, that these low power wireless devices are absolutely safe. Low power wireless devices emit low levels of radio frequency energy (RF) in the microwave range while being used. Whereas high levels of RF can produce health effects (by heating tissue), exposure to low level RF that does not produce heating effects causes no known adverse health effects. Many studies of low level RF exposures have not found any biological effects. Some studies have suggested that some biological effects might occur, but such findings have not been confirmed by additional research. This device has been tested and found to comply with FCC/IC radiation exposure limits set forth for an uncontrolled environment and meets the FCC radio frequency (RF) Exposure Guidelines in Supplement C to OET65 and RSS-102 of the IC radio frequency (RF) Exposure rules.