FCC PART 15 COMPLIANCE Compliance Statement (Part 15.19) WARNING:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference and
(2) This device must accept any interference received, including interference that may cause undesired operation. Warning (Part 15.21) Caution: Any change or modification not expressly approved by Zonar Systems could void the users authority to operate the equipment. 19518 INTERNATIONAL BLVD. SEATTLE, WA 98188.5493 877.THE.EVIR FAX: 206.878.3082 www.zonarsystems.com 2004 Zonar Systems, LLC is a registered trademark of Zonar Systems, LLC REV: 9/04 TABLE OF CONTENTS WHAT IT IS ...............................................................................................................................3 HOW THE SYSTEM WORKS...................................................................................................3 WHY IT MATTERS ...................................................................................................................3 EQUIPMENT DESCRIPTION ...................................................................................................4 KEYPAD & NAVIGATION .........................................................................................................5 SCHEMATIC OVERVIEW.........................................................................................................6 HOW TO USE......................................................................................................................7-10 INDEX OF FUNCTION ......................................................................................................11-12 1 LIMITED WARRANTY Zonar does not represent or warrant that the hardware and software are free of bugs or errors andshall not be liable for any losses (financial or non-financial) occurring as a result of such bugs orerrors. No other warranty express or implied, including any warranties of merchantability or particularpurpose, is provided for any hardware or software provided pursuant to this contract. Zonar shall not be liable to customer, or any third-party for any general, special, punitive, incidental, indirect or consequential damages, or any loss of profits or business, arising out of this agreement. In no event shall Zonars liability exceed the value of one months subscription paid by customer to Zonar, not to exceed one thousand dollars, under this agreement. Zonar warrants that the hardware and software comprise a verified safety inspection system which,when used according to Zonar's instructions, will allow the customer the ability to verify that safety inspections have occurred. However, Zonar disclaims any liability arising as a result of operator error (whether willful, negligent, or intentional) or misuse of the hardware or software. Customershall have no other liability and customer shall have no other remedy, except as specifically provided in this paragraph; and in no event shall Zonar be liable for any consequential damages. The terms and conditions of this agreement shall apply to any replacement hardware and software furnished. 2 WHAT IT IS The Zonar 2010 Replaces Paper Forms For Safety Inspections If youre driving and stopped by a state trooper or police officer, youll use the Zonar 2010 to provide on-road inspection verification. The Zonar 2010 replaces all the paperwork thats required by Federal and State regulations for your pre and post-trip inspections. Its a handheld reader for radio frequency identification (RFID) tags. The RFID tags have been placed around the vehicleyou drive in critical inspection areas or zones. Sonow as you go around the vehicle checkingcomponents, instead of paper forms, youll use theZonar 2010. Safety Inspection Information Stored In A Computer Instead of Boxes HOW THE ZONAR SYSTEM WORKS The Zonar 2010s Part of An Electronic Safety Inspection System The information about safety inspections that you record in the Zonar 2010 gets transmitted tocomputers at Zonar Systems via the Internet. How?
Youll place the Zonar 2010 into a Reader Downloading Station (RDS) thats been installed where you work. Management, safety, and maintenance personnel access the pre and post trip inspection reports from The Zonar System is a paperless, electronic safetyinspection system. In other words, the power of their computers. No more passing of paper, computers and the Internet eliminate the hassles complaints about lost reports and illegible handwriting,and unnecessary delays in getting repairs made. of dealing with paperwork. Recording, reviewing,storing, and managing vehicle inspections becomes easier and faster. And most importantly, the Zonar System helps make sure that youre always drivinga safe vehicle. WHY IT MATTERS Specially Programmed Radio Frequency Identification (RFID) Tags RFID tags have been put on the vehicle in critical inspection areas or zones. The RFID tags, which are weather-resistantthey can withstand mud, grease, and even icecontain information about their location on the vehicle, fleet numbers, and the components you need to inspect. The Zonar 2010 reads the tags and then promptsyou to indicate whether the components in a particularzone are OK or BAD. When you find problems withcomponents, youll select descriptions of their defective conditions from a list. Then, youll decide whether or not its safe to operate the vehicle with the defective conditions. If youre driving and stopped by a state trooper or police officer, youll use the Zonar 2010 to provide on-road inspection verification. Safety Inspection Information Stored In A Computer Instead of Boxes The Zonar 2010 reads the tags and then prompts you to indicate whether the components in a particular zone are OK or BAD. When you findproblems with components, youll select descriptions of their defective conditions from a list. Then, youll decide whether or not its safe to operate the vehicle with the defective conditions. The information about safety inspections that you record in the Zonar 2010 gets transmitted tocomputers at Zonar Systems via the Internet. How?
Youll place the Zonar 2010 into a Reader Downloading Station (RDS) thats been installed where you work. Management, safety, and maintenance personnel access the pre and post trip inspection reports from their computers. No more passing of paper, complaints about lost reports and illegible handwriting,and unnecessary delays in getting repairs made. 3 EQUIPMENT DESCRIPTION 06/15/02 08:30 REPORT HISTORY CURRENT REPORT >
MANUAL INSP SET CONTRAST VERSION STORE CURR RPT SELECT ITEM Spotlights
> Cursor character Display Window UP arrow Light (for spotlights) button RIGHT arrow READ/ENTER button DOWN arrow Green Y (yes) button Date/Time;
Spotlight Indicator;
Battery Level;
(Title Line) Instruction Line Info button for main menu LEFT arrow Red N (no) button Power button for turning Zonar 2010 ON/OFF Charging indicator Light Power/Data Connector 4 USE:
Power button Info button READ/ENTER button Light button UP arrow DOWN arrow RIGHT arrow LEFT arrow KEYPAD & NAVIGATION TO:
Turn the Zonar 2010 on/off Return to the main menu at any time (except when youre being prompted to enter a value or answer a question) Read a card or tag Enter mileage/hours Turn the spotlights on/off Scroll up Add by increments of 1 (e.g. for mileage or screen contrast) Accelerate adding increments up to 10,000: hold after pressing Scroll down Decrease by increments of 1 Accelerate decreasing increments: hold after pressing View the next screen for an item that has the cursor character
> displayed Add by increments of 10 Accelerate adding increments up to 10,000: hold after pressing Go back to previous screen Decrease by increments of 10 Accelerate decreasing increments: hold after pressing Red N (no button) Answer No to questions Enter a Red condition (for components that are BAD) Green Y (yes button) Answer Yes to questions Enter a Green condition (for components that are OK) Charging indicator light Check for a steady green light when the battery is charging Check for a flashing green light when the batteries are fully charged 5 6 HOW TO USE THE ZONAR 2010 FOR SAFETY INSPECTIONS Complete Pre/Post-trip Inspections Turn on the Zonar 2010
- Remove the Zonar 2010 from its vehicle mount
- Press Power button Log in
- Press READ/ENTER button
- Place your Zonar ID Card within 2 inches of the Zonar 2010s spotlights
- Press any button after reviewing System Info screen
- Select inspection configuration using the Right button on the desired inspection. (Multi configuration only)
- Wait for Report History screen to appear Review previous inspection report (located at top of the list on Report History screen) IF THE PREVIOUS REPORT IS:
OK BAD THEN:
Press Info to go to main menu Press RIGHT arrow to go to BAD report screen Press RIGHT arrow to go to ZONES screen to view which zones have defective components Use the UP/DOWN arrows to go to a defective zone (R or Y) Note: Green = OK; Yellow = defective condition but safe to operate;
Red = defective conditionnot safe to operate Press RIGHT arrow to view display that lists defective components conditions Press Info to go to main menu Read the Asset tag
- Position the Zonar 2010s spotlights within 2 inches of Asset tag; press READ/ENTER button
- Verify that vehicle number appears on screen
- Enter vehicles mileage 7 TO:
Add increments of 1 Decrease increments of 1 Add increments of 10 Decrease increments of 10 Record the mileage in the report THEN:
Press the UP arrow Press the DOWN arrow Press the RIGHT arrow Press the DOWN arrow Press READ/ENTER Note: Holding the arrow buttons accelerates adding or decreasing increments. Inspect all the components in a zone
- Go to a zone (following the order youve been given)
- Position the Zonar 2010s spotlights within 2 inches of RFID tag
- Press READ/ENTER
- Inspect each component listed
- Determine if each component is OKno defects IF THE CONDITION OF:
THEN:
All the components are OK Press the green Y (yes) button Verify that theres a G for a green condition
(OK) by the zone Inspect the next zone One or more of the components arent OK Press the red N (no) button
- Identify the defective condition(s) for each component that isnt OK TO:
THEN:
View a list of defective conditions for a component Select a defective condition from the list of defective conditions for a component Highlight the component with the defective condition (by scrolling with the UP and DOWN arrows); press the RIGHT arrow Highlight the defective condition from the list
(by scrolling with the UP and DOWN arrows);
press the RIGHT arrow 8
- Decide whether the vehicle is safe to operate with the defective condition(s) IF:
THEN:
The vehicle is safe to operate with the defective condition Press the green Y (yes) button to flag the defect as Yellow The vehicle isnt safe to operate with the defective condition Press the red N (no) button to flag the defect as Red Note: If you need to enter a component thats not listed:
1) Scroll to OTHER 2) Press the RIGHT arrow to go to the next screen 3) Use the UP, DOWN, RIGHT, LEFT arrows to select the character you want 4) Press READ/ENTER to highlight the character (the maximum number of characters you canenter is 18) 5) Erase text or add a space using < or > characters 6) Press the Info button when youve completed entering text for the OTHER component. (A screen titled OTHER will be displayed with a list of defective conditions.) 7) Highlight the defective condition for this OTHER component (by scrolling with the UP and DOWN arrows); press the RIGHT arrow 8) Decide if the vehicle is safe to operate with this defective condition; press the red N (no) button if it isnt OR press the green Y (yes) button if the vehicle is safe to operate with this defective condition. Note: If you need to enter a description of a condition thats not listed:
1) Scroll to OTHER 2) Press the RIGHT arrow to go to the next screen 3) Use the UP, DOWN, RIGHT, LEFT arrows to select the character you want 4) Press READ/ENTER to highlight the character (the maximum number of characters you canenter is 18) 5) Erase text or add a space using < or > characters 6) Press the Info button when youve completed entering text for the OTHER condition 7) Decide if the vehicle is safe to operate with this defective condition; press the red N (no) button if it isnt OR press the green Y (yes) button if the vehicle is safe to operate with this defective condition
- Continue inspecting the zones until the question mark in front of each zone on the ZONES screen has been replaced with a G, Y, or R WHEN:
THEN:
Youre ready to inspect the next zone Go to the next zone Position the Zonar 2010 within 2 inches of RFID tag; press READ/ENTER Follow the directions above for inspecting a zone 9 Store the current report IF:
AND:
THEN:
The Store Report screen appears after youve inspected all the zones Youre ready to make a permanent record of the inspection report Press the green Y (yes) button The Store Report screen appears after youve inspected all the zones Youre not ready to make a permanent record of the inspection report Press the red N (no) button Note: Youll return to the Zones screen and can make changes The Incomplete Report screen appears after selecting StoreCurr Report from the Main Menu You want to go back and complete inspecting the missinglisted zone(s) The Incomplete Report screen appears after selecting StoreCurr Report from the Main Menu You dont want to go back and complete inspecting the missinglisted zone(s) Press the red N (no) button Go back and inspect the missing components Follow directions for storing the current report Press the green Y (yes) button to make a permanent record of the incomplete report Note: An incomplete report is recorded as BAD on the Report History screen Turn off the Zonar 2010s power
- Press Power button Return the Zonar 2010 to its vehicle mount between trip inspections
- Transmit Completed Pre/Post-trip Inspections To Zonar Systems Place Zonar 2010 into Reader Downloading Station (RDS) WHEN:
THEN:
The inspections reports are being transmitted The light on the cradle changes from green to red The screen shows: Downloading The light on the cradle is red Dont remove the Zonar 2010 from the cradle The light on the cradle changes from red to green The transmission is complete and you can remove the Zonar 2010 from the cradle Charge The Zonar 2010s Batteries Place the Zonar 2010 into its vehicle mount (connected to the 12V power using a cigarette ighter adapter or wired directly to the electrical system) Note: While the Zonar 2010 is in its vehicle mount or RDS, the CHARGING indicator light will bea steady green. When the batteries are fully charged, the CHARGING light flashes green. Whilethe time to fully charge the batteries varies depending upon the beginning battery level, it typicallytakes four hours to fully charge the batteries. 10 INDEX of FUNCTIONS TO:
THEN:
Activate the RFID tags so they can be read Position the Zonar 2010s spotlights within 2 inches of tag; press READ/ENTER Add incremental values of 1 Add incremental values of 10 Accelerate adding/decreasing values Answer No to questions Answer Yes to questions Charge the batteries Darken the text on screens Press the UP arrow Press the RIGHT arrow Hold the (UP/RIGHT/DOWN/LEFT) arrow after pressing Press the red N (no) button Press the green Y (yes) button Place the Zonar 2010 into its vehicle mount, 10x charger or RDS Highlight SET CONTRAST from main menu by scrolling the cursor with the DOWN arrow;
press the RIGHT arrow Press the UP arrow to increase the percentage Press READ/ENTER to set contrast Decrease incremental values by 1 Press the DOWN arrow Decrease incremental values by 10 Delete text Press the LEFT arrow Use the < character Determine the battery level of the main menu Determine operator who stored previous report Enter a Green condition
(for components that are OK) Enter mileage hold to accelerate adding increments Locate the drawing of a battery on the title line Note: Completely black = fully charged Press the RIGHT arrow after REPORT HISTORY on the main menu Press the RIGHT arrow after the first report in the list on the REPORT HISTORY screen (to go to the next screen) Highlight OPERATOR Press the green Y (yes) button Position the Zonar 2010s spotlights within 2 inches of Asset tag; press READ/ENTER button Use the UP/RIGHT arrows to add increments;
Press READ/ENTER 11 INDEX of FUNCTIONS TO:
THEN:
Enter text for an OTHER component or condition thats not listed Enter a Red condition (for components that are BAD) Highlight your selection from a list Lighten the text on screens Log in Read a RFID tag Review most recent inspection report Store the current report Use the UP, DOWN, RIGHT, LEFT arrows to select the character you want (use the >
character for a space; to erase text use the
< character) Press READ/ENTER Press the Info button when youve completed entering text Note: The maximum number of characters you can select is 18. Press the red R (no) button Scroll the UP/DOWN arrows to make your selection Highlight SET CONTRAST from main menu by scrolling the cursor with the DOWN arrow Press the RIGHT arrow Press the DOWN arrow to decrease the percentage Press READ/ENTER to set contrast Press READ/ENTER button Place your Zonar ID Card within 2 inches of the Zonar 2010s spotlights Position the Zonar 2010s spotlights within 2 inches of tag Press READ/ENTER Press the RIGHT arrow after REPORT HISTORY on the main menu Press the RIGHT arrow after the first report in the list on the REPORT HISTORY screen Press the green Y (yes) button when the Store Report screen appears Transmit completed pre and post inspection reports to Zonar Systems Place Zonar 2010 into Reader Downloading Station (RDS) Turn the Zonar 2010 on/off Press the Power button once to turn the Zonar 2010 on or off Turn the spotlights on/off Press the Light button View the next screen for an item that has the character > displayed Press the RIGHT arrow 12