904 RFID/2 LEGIC 13.56MHz proximity R/W modules p/n 904.205.15 - Magstripe output or TTL serial module p/n 904.206.15 - RS232 or Wiegand or buffered Clock &
Data module. AXESS TMC srl Via della Filanda, 22 - 40133 Bologna - Italy Tel:+39 051 3519311 - Fax: +39 051 3519399 www.axesstmc.com Reader technology Transponder types Interface LEGIC SC2560 based proximity read-write interface for ISO15693 & ISO14443A tags LEGIC prime (13.56MHz proprietary), advant (ISO15693 and ISO14443A) Electrical: According to model p/n and pins. Data format: According to configuration pins. About 4 cm with ISO cards. Dont mount the reader directly on metal surface. Two LEDs (Red and Green) driven by connecting Yellow and Grey wires to GND. p/n 904.205.15: 5 Vdc. (+/-10%), 150mA typical. p/n 904.206.15: 5 to 18 Vdc, 150mA typical. 101 x 44 x 23 mm (outline)
-25 to +60C. 300 cm, PVC, 10 wires (904.205.15) or 12 wires, no connector (904.206.15). WARNING: connect first GND blue wire, then other connections, leaving Vdc last one. Configuration Pins
Output Format Brown 2Color wires - 904.206.15 only GreyPink BluRed Green (x) Serial/RS232 TO GND 19200,N,8: TO GND 38400,N,8: OPEN OPEN
(RXD) Magstripe Clk&Data OPEN TO GND OPEN TO GND Wiegand
(904.206.15 only) OPEN OPEN TO GND TO GND Reading range Visual indication Power supply Dimensions Temperature range Interface Cable Data transmission Readers are preprogrammed for automatic retrieving and transmission of any of a few common known segments data, or (if known segments are missing) of the UID code always present in all cards. UID is output in Magstripe emulation as binary conversion to a string of 20 decimal figures (10 figures for each 4Bytes/32bits group). Note: The preprogrammed logical output, is not proper for the Wiegand output. Proper logical output format, in general, can be reprogrammed with the TMC LEGIC configuration utility or CSW2000 program by LEGIC. Blue Red 904.205.15 904.206.15 GND Power 5 (+/-0.5) Vdc Green RXD serial TTL RXD - RS232 (x) White TXD serial TTL / Data TXD - RS232 Pink Black Clock Data0 / Clock Data1 / Data Yellow GREEN LED OFF = OPEN, ON = TOGND WARNING: Make all the connections before applying the power supply to the reader. Never connect the configuration pins (Brown, GreyPink or BluRed) to the Vdc. Gray Violet RED LED OFF = OPEN, ON = TOGND Reserved for FW upgrades do not connect. Connector - 904.205.15 only Output Assignment for TMC MAX Output for TMC PROX & TRAX The TTL output version only is supplied with a 8-pin MOLEX connector. It is factory configured for using (as a magnetic emulation reader) with TMC 914.003.20 HotMAX boards. Connection to PROX (and TRAX) terminals is also possible changing the pins order and reducing the connector as shown in the rightmost table. Note: to modify the pin connections or change the connector size, just press a little with a screwdriver into the corresponding rectangular hole and pull the wire at the same time. Then re-insert it in the required position. Blue Red Pink 1 2 3 4 5 White 6 7 Yellow 8 Gray GND Power 5 Vdc Clock Output Data Output GREEN LED RED LED 5 Red 4 Blue 3 White 2 Pink 1 Power 5Vdc GND Data Output Clock Output
(n.c.) 1 2 3 4 5 6 7 8 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. INSTRUCTIONS FOR FCC ID LABELING Module type: transmitter 90401-15 FCC-ID: SYL90401-15 This intends to inform you how to specify the FCC ID of our transmitter module 90401-15 on your final product. Based on the Public Notice from FCC, the product into which our transmitter module is installed must display a label referring to the enclosed module. The label should use wording such as Contains transmitter module FCC ID: SYL90401-15 or Contains FCC ID: SYL90401-15, any similar wording with the same meaning may be used. This device only conforms to all the standards of the CE mark if the installation and user instructions contained in this document are followed correctly. 904 RFID2 LEGIC Shortform-ENG-16.doc p.n.19040222