all | frequencies |
|
exhibits | applications |
---|---|---|---|---|
manual |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User Manual | Users Manual | 3.17 MiB | October 03 2014 / November 03 2014 | |||
1 | Cover Letter(s) | October 03 2014 / November 03 2014 | ||||||
1 | Cover Letter(s) | October 03 2014 / November 03 2014 | ||||||
1 | Cover Letter(s) | October 03 2014 / November 03 2014 | ||||||
1 | External Photos | October 03 2014 / November 03 2014 | ||||||
1 | Internal Photos | October 03 2014 / November 03 2014 | ||||||
1 | ID Label/Location Info | October 03 2014 / November 03 2014 | ||||||
1 | ID Label/Location Info | October 03 2014 / November 03 2014 | ||||||
1 | Test Report | October 03 2014 / November 03 2014 | ||||||
1 | Test Setup Photos | October 03 2014 / November 03 2014 |
1 | User Manual | Users Manual | 3.17 MiB | October 03 2014 / November 03 2014 |
User Manual EKI-1361/EKI-1362 1/2-port RS-232/422/485 to 802.11b/g/n WLAN Serial Device Server Copyright The documentation and the software included with this product are copyrighted 2013 by Advantech Co., Ltd. All rights are reserved. Advantech Co., Ltd. reserves the right to make improvements in the products described in this manual at any time without notice. No part of this manual may be reproduced, copied, translated or transmitted in any form or by any means without the prior written permission of Advantech Co., Ltd. Information provided in this manual is intended to be accurate and reliable. How-
ever, Advantech Co., Ltd. assumes no responsibility for its use, nor for any infringe-
ments of the rights of third parties, which may result from its use. Acknowledgements Intel and Pentium are trademarks of Intel Corporation. Microsoft Windows and MS-DOS are registered trademarks of Microsoft Corp. All other product names or trademarks are properties of their respective owners. Product Warranty (5 years) Advantech warrants to you, the original purchaser, that each of its products will be free from defects in materials and workmanship for two years from the date of pur-
chase. This warranty does not apply to any products which have been repaired or altered by persons other than repair personnel authorized by Advantech, or which have been subject to misuse, abuse, accident or improper installation. Advantech assumes no liability under the terms of this warranty as a consequence of such events. Because of Advantechs high quality-control standards and rigorous testing, most of our customers never need to use our repair service. If an Advantech product is defec-
tive, it will be repaired or replaced at no charge during the warranty period. For out-
of-warranty repairs, you will be billed according to the cost of replacement materials, service time and freight. Please consult your dealer for more details. If you think you have a defective product, follow these steps:
1. Collect all the information about the problem encountered. (For example, CPU speed, Advantech products used, other hardware and software used, etc.) Note anything abnormal and list any onscreen messages you get when the problem occurs. 2. Call your dealer and describe the problem. Please have your manual, product, 3. and any helpful information readily available. If your product is diagnosed as defective, obtain an RMA (return merchandize authorization) number from your dealer. This allows us to process your return more quickly. 4. Carefully pack the defective product, a fully-completed Repair and Replacement Order Card and a photocopy proof of purchase date (such as your sales receipt) in a shippable container. A product returned without proof of the purchase date is not eligible for warranty service. 5. Write the RMA number visibly on the outside of the package and ship it prepaid to your dealer. Part No. Edition 1 Printed in Taiwan December 2013 EKI-1361/EKI-1362 User Manual ii Declaration of Conformity CE This product has passed the CE test for environmental specifications. Test conditions for passing included the equipment being operated within an industrial enclosure. In order to protect the product from being damaged by ESD (Electrostatic Discharge) and EMI leakage, we strongly recommend the use of CE-compliant industrial enclo-
sure products. FCC Class B Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installa-
tion. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful inter-
ference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interfer-
ence to radio or television reception, which can be determined by turning the equip-
ment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help. Declaration of Conformity For Wireless Device This device complies with Industry Canada licence-exempt RSS standard(s).Opera-
tion is subject to the following two conditions: (1) this device may not cause interfer-
ence, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. For ITE Products Industry Canada - Class B This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the interference-causing equipment standard enti-
tled Digital Apparatus, ICES-003 of Industry Canada. iii EKI-1361/EKI-1362 User Manual Technical Support and Assistance 1. Visit the Advantech web site at www.advantech.com/support where you can find the latest information about the product. 2. Contact your distributor, sales representative, or Advantech's customer service center for technical support if you need additional assistance. Please have the following information ready before you call:
Product name and serial number Description of your peripheral attachments Description of your software (operating system, version, application software, etc.) A complete description of the problem The exact wording of any error messages Safety Instructions 1. Read these safety instructions carefully. 2. 3. Disconnect this equipment from any AC outlet before cleaning. Use a damp Keep this User Manual for later reference. 4. 5. 6. 7. cloth. Do not use liquid or spray detergents for cleaning. For plug-in equipment, the power outlet socket must be located near the equip-
ment and must be easily accessible. Keep this equipment away from humidity. Put this equipment on a reliable surface during installation. Dropping it or letting it fall may cause damage. The openings on the enclosure are for air convection. Protect the equipment from overheating. DO NOT COVER THE OPENINGS. 8. Make sure the voltage of the power source is correct before connecting the 9. equipment to the power outlet. Position the power cord so that people cannot step on it. Do not place anything over the power cord. 10. All cautions and warnings on the equipment should be noted. 11. If the equipment is not used for a long time, disconnect it from the power source to avoid damage by transient overvoltage. 12. Never pour any liquid into an opening. This may cause fire or electrical shock. 13. Never open the equipment. For safety reasons, the equipment should be 14. opened only by qualified service personnel. If one of the following situations arises, get the equipment checked by service personnel:
The power cord or plug is damaged. Liquid has penetrated into the equipment. The equipment has been exposed to moisture. The equipment does not work well, or you cannot get it to work according to the user's manual. The equipment has been dropped and damaged. The equipment has obvious signs of breakage. 15. DO NOT LEAVE THIS EQUIPMENT IN AN ENVIRONMENT WHERE THE STORAGE TEMPERATURE MAY GO BELOW -40 C (-40 F) OR ABOVE 80 C (140 F). THIS COULD DAMAGE THE EQUIPMENT. THE EQUIPMENT SHOULD BE IN A CONTROLLED ENVIRONMENT. EKI-1361/EKI-1362 User Manual iv 16. CAUTION: DANGER OF EXPLOSION IF BATTERY IS INCORRECTLY REPLACED. REPLACE ONLY WITH THE SAME OR EQUIVALENT TYPE RECOMMENDED BY THE MANUFACTURER, DISCARD USED BATTERIES ACCORDING TO THE MANUFACTURER'S INSTRUCTIONS. 17. The sound pressure level at the operator's position according to IEC 704-1:1982 is no more than 70 dB (A). DISCLAIMER: This set of instructions is given according to IEC 704-1. Advantech disclaims all responsibility for the accuracy of any statements contained herein. Safety Precaution - Static Electricity Follow these simple precautions to protect yourself from harm and the products from damage.
To avoid electrical shock, always disconnect the power from your PC chassis before you work on it. Don't touch any components on the CPU card or other cards while the PC is on.
Disconnect power before making any configuration changes. The sudden rush of power as you connect a jumper or install a card may damage sensitive elec-
tronic components. v EKI-1361/EKI-1362 User Manual EKI-1361/EKI-1362 User Manual vi Contents Chapter Chapter Chapter 21 1 1.1 1.2 1.3 1.4 2 2.1 2.2 2.3 2.4 3 3.1 3.2 3.3 3.4 Overview...............................................1 Introduction ............................................................................................... 2 Features .................................................................................................... 3 Specifications ............................................................................................ 3 Package Check List .................................................................................. 5 Getting Started.....................................7 Understanding EKI-1361/EKI-1362........................................................... 8 2.1.1 Product Description....................................................................... 8 Figure 2.1 Dual Ethernet Connections......................................... 8 2.1.2 COM Port Redirector (Virtual COM Port)...................................... 9 Figure 2.2 COM Port Redirector .................................................. 9 Figure 2.3 Multi-Access Mode ................................................... 10 2.1.3 TCP Server Mode ....................................................................... 11 Figure 2.4 TCP Server Mode..................................................... 11 2.1.4 TCP Client Mode......................................................................... 11 Figure 2.5 TCP Client Mode ...................................................... 11 2.1.5 Serial Tunneling Mode ................................................................ 12 Figure 2.6 Serial Tunneling Mode.............................................. 12 2.1.6 UDP Server/Client Mode............................................................. 12 2.1.7 Control Mode .............................................................................. 12 Hardware................................................................................................. 13 LED Indicators ............................................................................ 13 2.2.1 Table 2.1: EKI-1361/1362 series LED Indicators ...................... 13 2.2.2 Dimensions (Units: mm).............................................................. 14 Figure 2.7 DIN-Rail Mount of EKI-1361 ..................................... 14 Figure 2.8 Wall Mount of EKI-1361............................................ 14 Figure 2.9 DIN-Rail Mount of EKI-1362 ..................................... 15 Figure 2.10Wall Mount of EKI-1362............................................ 15 Connecting Hardware ............................................................................. 16 2.3.1 Choosing the Location ................................................................ 16 Figure 2.11Combine the Metal Mounting Kit .............................. 16 Figure 2.12DIN-rail Step 2 .......................................................... 16 2.3.2 Wireless Connection ................................................................... 17 2.3.3 Network Connection.................................................................... 17 2.3.4 Power Connection....................................................................... 17 Figure 2.13Power Connector...................................................... 17 2.3.5 Serial Connection........................................................................ 18 Table 2.2: EKI-152X series Serial Pin Assignments.................. 18 Installing the Configuration Utility............................................................ 18 Configuration .....................................21 Configuration Utility Overview ................................................................. 22 Discovering Serial Device Servers .......................................................... 23 3.2.1 Auto Searching ........................................................................... 23 3.2.2 Clear Device List and Search Again ........................................... 25 3.2.3 Manual Appending ...................................................................... 25 Network Settings ..................................................................................... 26 Administrator Settings ............................................................................. 28 vii EKI-1361/EKI-1362 User Manual Chapter 4 4.1 Locate the Serial Device Server ................................................. 28 3.4.1 3.4.2 Lock the Serial Device Server (Password Protection) ................ 28 3.4.3 Restore to Factory Default Settings............................................ 30 3.4.4 Update Firmware ........................................................................ 31 Setting COM Redirector ................... 33 Setting COM Redirector (Virtual COM port)............................................ 34 4.1.1 Auto Mapping.............................................................................. 34 4.1.2 Manual Mapping ......................................................................... 36 4.1.3 Manual Direct Mapping Virtual COM Port................................... 38 4.1.4 Remove the Virtual COM Port .................................................... 38 Chapter 5 Web-Based Configuration................ 41 5.1 5.2 5.3 5.4 5.5 5.6 5.7 5.8 5.9 5.10 5.11 6 6.1 6.2 6.3 Overview ................................................................................................. 42 Accessing the Web Page........................................................................ 42 System .................................................................................................... 43 Network Configuration ............................................................................ 44 Wireless Configuration............................................................................ 45 Port Configuration ................................................................................... 48 5.6.1 Basic Port Configuration ............................................................. 49 5.6.2 Operation Mode .......................................................................... 49 Monitor .................................................................................................... 57 Auto Warning (Alarm) ............................................................................. 58 5.8.1 Email Alert .................................................................................. 58 5.8.2 SNMP Trap ................................................................................. 59 5.8.3 System Event.............................................................................. 59 5.8.4 Serial Port Event......................................................................... 60 Change Password................................................................................... 60 Import/Export Device Settings ................................................................ 61 Reboot .................................................................................................... 62 Telnet Configuration......................... 63 Overview ................................................................................................. 64 Telnet Console........................................................................................ 64 Command List......................................................................................... 65 Table 6.1: Console Command List ............................................ 65 Chapter Appendix A Pin Assignments............................... 79 A.1 Pin Assignments ..................................................................................... 80 A.1.1 RS-232 Pin Assignments............................................................ 80 A.1.2 RS-422/485 Pin Assignments..................................................... 80 Appendix B List of Known TCP and UDP Port Numbers ............................................ 81 B.1 List of Known TCP and UDP Port Numbers ........................................... 82 EKI-1361/EKI-1362 User Manual viii Chapter 1 1 Overview 1.1 Introduction Advantech's EKI-1300 series of Industrial Device Servers are a robust, feature-rich, and cost effective way to network-enable equipment in an industrial automation envi-
ronment. The EKI-1361/1362 provides one or two serial ports, 802.11b/g/n wireless LAN interface to connect any RS-232/422/485 devices to wireless LAN. These wire-
less serial device servers provide serial-to-wireless network connectivity as an alter-
native to wired Ethernet connectivity and enable virtually any serial device or equipment to be remotely accessed, controlled, monitored, or shared on an 802.11b/
g/n wireless network. By encapsulating serial data and transporting it over Ethernet, the EKI-1361/1362 allows virtual serial links over Ethernet IP-based networks. After Advantech Serial Device Server Configuration Utility installed, standard serial operation calls with vir-
tual COM port could be transparently redirected to the serial device servers, guaran-
teeing compatibility with legacy serial devices and enabling backward compatibility with existing software. EKI-1361/1362 also supports serial tunneling, allowing two native serial devices to communicate over a network without any hosts or program-
ming. As a result, you can extend limited distance, point-to-point, direct serial con-
nections within the plant, throughout the factory, the facility, the office building, or across the global enterprise. The EKI-1361/1362 provides an impressive list of features and functions enabling multiple industrial devices to be connected, controlled, configured, managed, and updated over a network. With serial ports and 802.11b/g/n wireless LAN, the EKI-
1361/1362 can easily connects multiple serial devices to a network. The transmission speed of the EKI-1361/1362 is up to 921.6 Kbps totally outstripping the competition to meet the demand for high-speed exchange. Functionally transparent and efficient, the EKI-1361/1362 is especially designed for remotely controlling and monitoring devices via the Internet. The EKI-1361/1362 provides roaming ability. EKI-1361/1362 can midgrate from AP to AP during certain condition. In some field applications, the device can't use a fixed physical connection, such as AGV, transportation, and cross wide space communica-
tion. EKI-1361/1362 can easily installed to fulfill this requirement. With compact size and lightweight design, EKI-1361/1362 could be installed onto the moving vehicle without much extra loading. Types of supported devices:
Human Machine Interface (HMI)
Programmable Controller(PLC)
Flow meters
Temperature / pressure monitoring equipment
Gas leak detection device
Scales
Power monitoring equipment
Data Acquisition Modules EKI-136X series provides various operation modes: COM port redirection (Virtual COM port), TCP/UDP server/client mode. Serial devices can be connected by means of multi-access modes. EKI-1361/EKI-1362 User Manual 2 C h a p t e r 1 O v e r v e w i 1.2 Features
Support standard Wireless 802.11 b/g/n
Support MIMO 2x2 technology
Expand up 4096 serial ports for one single host
Provides 10/100/1000 Mbps auto-sensing Ethernet ports for easy diagnostic
Supports any baud rate setting from 50 bps up to 921.6 Kbps
Supports various operation modes: COM port redirection (Virtual COM port), TCP server/client, UDP server/client, control mode and RFC-2217 mode
Easy to diagnostic LED indicators
Supports multi-access features: allows maximum 5 hosts to access one serial port simultaneously
Allows maximum 16 peers in TCP/UDP client mode
Mounts on DIN rail, wall, or panel easily
Surge protection for RS-422/485 line and power supply
SNMP MIB-II for network management 1.3 Specifications WLAN Interface
Standard Conformance: 802.11b, 802.11g, and 802.11n
Network Modes: Infrastructure, Ad-Hoc
Transmit Power:
802.11b: +16 dBm (typical) 802.11g: +16 dBm @ 6~36 Mbps, +11 dBm @ 54Mbps 802.11n/HT20: +16 bBm @ MCS 0 ~ 3, +9 dBm @ MCS 7, +19dBm @ MCS 9, +11 dBm @ MCS 15 802.11n/HT40: +16 bBm @ MCS 0 ~ 3, +8 dBm @ MCS 7, +19dBm @ MCS 9, +11 dBm @ MCS 15
Receive Sensditivity: -82 dBm (Max.)
Data Rate:
802.11b: 1, 2, 5.5, and 11 Mbps 802.11g: 6, 9, 12, 18, 24, 36, 48, and 54 Mbps 802.11n:
- 20 MHz Channel:
1Nss: 65 Mbps @ 800 GI, 72.2 Mbps @ 400 GI (Max.) 2Nss: 130 Mbps @ 800 GI, 144.4 Mbps @ 400 GI (Max.)
- 40 MHz Channel:
1Nss: 135 Mbps @ 800 GI, 150 Mbps @ 400 GI (Max.) 2Nss: 270 Mbps @ 800 GI, 300 Mbps @ 400 GI (Max.)
Transmission Distance: Up to 100 meters (in open areas with bundle external antenna)
Wireless Security:
WEP: 64-bit/128-bit data encryption WPA, WPA2, 802.11i: Enterprise mode and Pre-Share Key (PSK) mode Encryption: EAP-TLS, EAP-TTLS, EAP-PEAP
Antenna Connector: Reverse SMA 3 EKI-1361/EKI-1362 User Manual Bundle Externel Antenna
Frequency Range: 2.4GHz ~ 2.5GHz
Impedanc: 50 Nominal
VSWR: 1.92:1Max.
Return Loss: 10dB Max.
Radiation: Omni-directional
Gain(Peak): 2dBi
Polarization: Linear; Vertical
Admitted Power: 1W LAN
Ethernet: 10/100 Mbps auto sensing
No. of Ports: 1
Port Connector: RJ45
Protection: Built-in 1.5 KV magnetic isolation Serial Interface
Interface: RS-232/422/485, software selectable
No. of Ports:
EKI-1361: 1 EKI-1362: 2
Port Connector: DB9 male
Baud Rate: 50 bps to 921.6 Kbps
Parity: None, Even, Odd, Space, Mark
Data bits: 5, 6, 7, 8
Stop bits: 1, 1.5, 2
Flow control: XON/XOFF, RTS/CTS, DTR/DSR
Signals:
RS-232: TxD, RxD, CTS, RTS, DTR, DSR, DCD, RI, GND RS-422: TxD+, TxD-, RxD+, RxD-, GND RS-485: Data+, Data-, GND
Protection: 15 KV ESD for all signals, enhanced protection for RS-422/485 lines Software
Utility: Advantech Serial Device Server Configuration Utility
Driver support: Windows 2000/XP/Vista/7, Windows Server 2003/2008, Linux
Operation Mode:
COM port redirection (Virtual COM) TCP/UDP server (polling) mode TCP/UDP client (event handling) mode Pair connection mode
Configuration: Web interface, Windows utility, Telnet console
Protocol: ICMP, IP, TCP, UDP, BOOTP, DHCP, Auto IP, Telnet, SNMP, HTTP, DNS, SMTP, ARP, NTP
Management: SNMP MIB-II EKI-1361/EKI-1362 User Manual 4 General
LED indicators:
System: Power, System Status WLAN: Signal Strength, Link LAN: Speed, Link/Active Serial: Tx, Rx Power
Power input: 12 ~ 48 V(DC), redundant dual inputs
Power connector: Terminal block
Power Consumption:
EKI-1361: 8W EKI-1362: 9W
Power Line Protection: 1 KV burst (EN61000-4-4), 0.5 KV surge (EN51000-4-5) C h a p t e r 1 O v e r v e w i Environmental
Operation Temperature: -30 ~ 65C (-22 ~ 149F)
Storage Temperature: -40 ~ 80C (-40 ~ 176F)
Operating Humidity: 5 to 95% RH Regulatory Approvals
ECM: CE, FCC Part 15 Subpart B (Class B) 1.4 Package Check List
1 x EKI-1361/1362 Serial Device Server
Panel/Wall mounting bracket
DIN-rail mounting kit
CD-ROM for utility and user manual Optional Accessory:
OPT1-DB9-AE D-sub 9 (female) to terminal block connector (for EKI-1000 series RS-422/485 use) 5 EKI-1361/EKI-1362 User Manual EKI-1361/EKI-1362 User Manual 6 Chapter 2 2 Getting Started 2.1 Understanding EKI-1361/EKI-1362 The EKI-136X series are wireless-based, serial device servers for connecting RS-
232/422/485 devices to a TCP/IP network. Once connected through EKI series, the serial device will be able to send and receive data on a network like any other net-
work device. It extends traditional COM ports of a PC with access over a TCP/IP net-
work. Through networking, you can control and monitor remote serial devices either over a LAN or over the WAN. Since the EKI series is connected through a TCP/IP network, you might need to know some basic facts about networking in order to get the server hooked up correctly. 2.1.1 Product Description The EKI series is designed to network-enable any RS-232/422/485 serial device and provide industry-grade hardware and easy-use software to make connecting serial devices to an Ethernet network a surprisingly simple process. These units immedi-
ately upgrade your existing serial devices for integration into the Internet world. The EKI series features a lot of powerful functions such as: high speed data transfer, access-control, auto-detection of all EKI series products, remote connection from dif-
ferent network domain, remote firmware download, and more. After the simple installation steps to attach your network and serial device to the appropriate connectors on the serial device servers and driver installation, you will then be able to communicate with the serial devices via its own application software and with the EKI serial device server. COM port redirector, TCP server mode, TCP client mode, UDP server mode, UDP client mode and Control mode are all different schemes to make a serial connection across using one or more Serial device server. Figure 2.1 Dual Ethernet Connections EKI-1361/EKI-1362 User Manual 8 2.1.2 COM Port Redirector (Virtual COM Port) Advantech Serial Device Server Configuration Utility is a serial COM port redirector that creates virtual COM ports and provides access to serial device connected to Advantech serial device server. You can configure the serial device server and enable the Virtual COM port using one integrated utility. Advantech Serial Device Server Configuration Utility allows you to configure Microsoft applications to communicate with network enabled serial device servers as easily as if they were physically installed in or directly connected on the PC. The Advantech redirector can create up to 4096 virtual COM ports. Application on the host can open virtual COM port to access the serial device servers at the same time. The redirector will handle each active virtual COM port as a separate TCP connection to Advantech serial device servers. C h a p t e r 2 G e t t i n g S t a r t e d Figure 2.2 COM Port Redirector 2.1.2.1 Normal Mode The Advantech redirector connects the Advantech serial device servers while an application open the COM port and disconnects from the Advantech serial device servers when the application closes the COM port. The redirector uses TCP network connections to the Advantech serial device server to gain the access to the connected serial devices. 9 EKI-1361/EKI-1362 User Manual 2.1.2.2 Multi-Access Mode (Shared COM port mode) Most of serial devices are connected directly and physically to the PC serial ports via a cable. The operation system, ex. Windows XP, provides the COM ports that users application can access, and control the serial device through the serial cable. This means that the serial device can be connected to one host and only one application on this host can handle input, output and control operation on this device. If you want to run more than one applications to use a serial device, you can employ EKI serial device servers that provide a virtual COM port for a host or multi-hosts on an Ethernet network. EKI serial device server is located between hosts and serial devices. Each serial port on the EKI serial device server can allow max. five host connections through one Ethernet port or two Ethernet ports. There are two major operation modes for Multi-Access Mode. First one is broadcast mode; EKI serial device server handles a command from one application and replies the data from the serial port to all applications that are connecting this serial port. Another one is polling mode; EKI serial device server handles the command from one application and reply to this application only. Query from other applications must be queued and wait for current process completing. Figure 2.3 Multi-Access Mode By using a serial derive server to share serial device, you eliminate the separate serial lines and serial devices that can be attached to individual hosts. Collecting the data from these serial devices become more easily and more effectively. EKI-1361/EKI-1362 User Manual 10 2.1.3 TCP Server Mode In TCP server mode, you might initiate the TCP connection from host to EKI serial device server. This operation mode support max. 5 simultaneous connections for each serial port on EKI serial device server from one host or several hosts, however multi-hosts collect the data from one serial port at the same time 2.1.4 TCP Client Mode Figure 2.4 TCP Server Mode In TCP Client mode, the TCP connection will be established from EKI serial device server. This operation mode supports max.16 simultaneous connections for each serial port on EKI series to one host or several hosts. You should configure the IP address and TCP port number of the network hosts which the EKI serial device server connect to using Advantech Serial Device Server Configuration Utility. After configuration, when EKI serial device server receives the data from serial port, the device server will employ the connection to hosts which are configured. C h a p t e r 2 G e t t i n g S t a r t e d Figure 2.5 TCP Client Mode 11 EKI-1361/EKI-1362 User Manual 2.1.5 Serial Tunneling Mode Two native serial devices can communicate over an Ethernet network without any intermediate host PC and software programming. Serial Tunneling is very simple to use. You can use Advantech Serial Device Server Configuration Utility to designate one serial port as the tunneling master and another serial device server port as the tunneling slave. Figure 2.6 Serial Tunneling Mode 2.1.6 UDP Server/Client Mode UDP is used primarily for broadcasting messages over a network. In the UDP server mode, EKI series access max. 8 hosts UDP message. In the UDP client mode, EKI serial device servers transmit UDP message to max. 16 hosts simultaneously. 2.1.7 Control Mode In controlling mode, the EKI serial device server presents a modem interface to the attached serial device: it accepts AT-style modem commands to connect / disconnect to other networking device. If you want serial device running application program to connect/disconnect to different devices by request, you can use controlling mode. The controlling mode provides three kinds of modem AT-style commands. The serial devices can use these commands to control EKI series connecting or disconnecting to remote networking devices. Thus intelligent serial devices such as stand-alone PLC will send /receive data to/from devices one by one via Ethernet. EKI-1361/EKI-1362 User Manual 12 2.2 Hardware In this section, we will give you an overview of EKI-1361/EKI-1362 hardware and installation. 2.2.1 LED Indicators There are LEDs display the power status, network status, and serial communication status located on the front panel of EKI-1361/EKI-1362, each of them has its own specific meaning as below table. Table 2.1: EKI-1361/1362 series LED Indicators LED Name LED Color LED Description PWR1 PWR2 Status Green Off Green Off Status Power 1 is on. Power 1 is off, or power error condition exists. Power 2 is on. Power 2 is off, or power error condition exists. Blinking: System is ready. Steady on: The device server has been located by utilitys location function. Off System is not working. LAN Green Blinking: Ethernet port is transmitting or receiving data. Steady on: Ethernet has the good link for 10Mbps or 100Mbps operations. C h a p t e r 2 G e t t i n g S t a r t e d WLAN Signal Strength Off Ethernet is not working. Orange Steady on: WLAN link is ready Off Off Orange
(One) Orange
(Two) Orange
(Three) WLAN is not working. 0~25% WLAN signal strength. 25~50% WLAN signal strength. 50~75% WLAN signal strength. 75~100% WLAN signal strength. Tx, Orange Serial port is transmitting data. Serial Rx, Green Serial port is receiving data. Off No data is transmitted or received through the serial port. 13 EKI-1361/EKI-1362 User Manual 2.2.2 Dimensions (Units: mm) Figure 2.7 DIN-Rail Mount of EKI-1361 Figure 2.8 Wall Mount of EKI-1361 EKI-1361/EKI-1362 User Manual 14 C h a p t e r 2 G e t t i n g S t a r t e d Figure 2.9 DIN-Rail Mount of EKI-1362 Figure 2.10 Wall Mount of EKI-1362 15 EKI-1361/EKI-1362 User Manual 2.3 Connecting Hardware Next, we will explain how to find a proper location for your EKI series, and then explain how to connect to the network, hook up the power cable, and connect to the EKI series serial port. 2.3.1 Choosing the Location Due to its versatility and innovative design, EKI serial device server can be:
Fixed to a panel/wall mount
Fixed to a DIN-rail 2.3.1.1 Panel/Wall Mounting The EKI-1361/EKI-1362 can be attached to a wall using the included metal brackets. Each bracket comes with 3 screws; and then you can install the device firmly via the components, please see the figure as below. Figure 2.11 Combine the Metal Mounting Kit 2.3.1.2 DIN Rail Mounting You can mount the EKI-152X series on a standard DIN-rail. Please screw the DIN-rail kit on the serial device server first. Figure 2.12 DIN-rail Step 2 EKI-1361/EKI-1362 User Manual 16 2.3.2 Wireless Connection EKI-1361/EKI-1362 operates in the 802.11b/g/n WLAN environment, which is cre-
ated by an access point working with 802.11b/g/n protocols. When configuring EKI-
1361/EKI-1362 in unknown status, user can use the Ethernet port and Configuration Utility to locate device easily. After found device in the Configuration Utility, user can configure the Ethernet and Wireless IP address to access web interface for advanced settings including serial port operation mode and wireless configurations. More detail description can be found in next chapters. You can check the signal access strength with the WLAN signal strength LED indica-
tors. Adjust the antenna of the EKI serial device server to optimize communication quality. 2.3.3 Network Connection EKI-1361/EKI-1362 has a RJ-45 Ethernet port that supports 10 Mbps Ethernet, or 100 Mbps Fast Ethernet, and half or full duplex operation. EKI-1361/EKI-1362 can be connected to other hubs or switches through a twisted-pair straight through the cable or a crossover cable up to 100m long. When use EKI-1361/EKI-1362 for first time, user can connect to device with Configuration Utility. Or you can set the host's ip address in the same domain with device. Then user can use popular browser to connect web interface EKI-1361/EKI-1362 built-in for advanced configuration. 2.3.4 Power Connection The EKI-1361/EKI-1362 supports dual 12 to 48 VDC power inputs and power-fail relay output. C h a p t e r 2 G e t t i n g S t a r t e d Figure 2.13 Power Connector You can connect an alarm indicator, buzzer or other signaling equipment through the relay output. The relay opens if power input 1 or 2 fails (Open means if you connect relay output with an LED, the light would be off). 17 EKI-1361/EKI-1362 User Manual 2.3.5 Serial Connection EKI-1361/EKI-1362 provides 1 or 2 serial ports with DB9 (male) connectors. RS-232/
422/485 pin assignments as below:
Table 2.2: EKI-152X series Serial Pin Assignments Pin 1 2 3 4 RS-232 DCD RX TX DTR RS-422 TX-
RS-485 DATA-
-
-
-
-
TX+
DATA+
5 GND GND GND 6 DSR
-
-
7 RTS RX+
-
8 CTS
-
-
9 RI RX-
-
2.4 Installing the Configuration Utility The following section will show you how to install the Advantech serial device server configuration utility, a tool to set up and monitor the EKI serial device servers. Note!
Be sure the Microsoft .NET Framework on your host PC is greater than version 2.0. 1. Insert the Advantech industrial communication IEDG series driver utility CD into the CD-ROM drive (e.g. E:\) on the host PC. 2. Use Windows explorer or the Windows Run command to execute the setup pro-
gram, the path for the setup program on the CD-ROM should be: E:\Util-
ity&Driver\SerialDeviceServerConfigurationUtility\Serial_Device_Server_Config uration_Utility_[Version]_Release_[date].exe EKI-1361/EKI-1362 User Manual 18 3. Upon executing the setup program, the Welcome Dialog Box will be pop-up. Press the "Next" button to continue. 4. Carefully read the Software License Agreement, and press "Yes" to continue. C h a p t e r 2 G e t t i n g S t a r t e d 19 EKI-1361/EKI-1362 User Manual 5. The Setup program will specify a default installation path: C:\Program Files\Advantech eAutomation\Serial Device Server Configuration Utility\
6. After setup has copied all program files to your computer, click the <Finish> but-
ton to finish the installation. EKI-1361/EKI-1362 User Manual 20 Chapter 3 3 Configuration 3.1 Configuration Utility Overview Advantech provides an easy-to-use utility to configure the serial device servers through an Ethernet connection. User can use the utility to search or locate the device and configure it, even don't know the exactly ip address of the device. Advantech Serial Device Server Configuration Utility is an excellent device server management tool. You can connect and configure the local and remote Advantech serial device servers easily. Moreover, Virtual COM port will be enabled in the same utility. You may open the Serial Device Server Configuration Utility from the Windows Start Menu by clicking Start All Programs Advantech eAutomation Serial Device Server Configuration Utility. The Serial Device Server Configuration Utility will appear as below. There are four major areas in the serial device server configuration utility. 1. 2. Serial Device Server List Area: All devices will be searched and listed in this area. You can arrange different favorite group and virtual COM ports. Serial Device Server Information Area: Click on the serial device server or move cursor to the serial device server, the related information will be shown on this area. 3. Configuration Area: Click on the item on the Device Server List Area, the configuration page will display on the area. 4. Quick Tool Bar: Useful management functions shortcut. Note!
Please reserve TCP/UDP port 5048 and 5058 in your Ethernet network, configuration utility will use these ports to communicate with Advantech EKI-1000, ADAM-4570, and EDG-4500 serial device servers. EKI-1361/EKI-1362 User Manual 22 3.2 Discovering Serial Device Servers 3.2.1 Auto Searching Advantech Serial Device Server Configuration Utility will automatically search all the EKI-1000, ADAM-4570 and EDG-4500 series device servers on the network and show them on the Serial Device Server List Area of the utility. The utility provides an auto-search function to show your device(s) by simply executing the configuration utility program from the Start Menu. From here all device on the same network domain will be searched and display on Device Server List Area. You can click on the device name to show the features of the specific device. Click on the + before the model name, and the utility will expand the tree structure to show the individual device name. Click on the - before the model name, and the utility will collapse the tree structure. C h a p t e r 3 C o n f i g u r a t i o n Note!
The default device name shown in the Configuration Utility will be the device model name appended with last 3 bytes of MAC address. You can change to a meaningful name for identification. 23 EKI-1361/EKI-1362 User Manual Select the device in this sub-tree. The first tab on the Configuration Area shows the summary of Basic Information included device type, version, and name, Ethernet Information, and Serial Port Information. In the serial port information frame, it dis-
plays the operation mode, status and connected host IP. Click on the + before the device name, and the utility will expand the interfaces on this device server. Click on each item, you will entry the configuration page to change the setting. The configuration will be introduced on following sections. EKI-1361/EKI-1362 User Manual 24 3.2.2 Clear Device List and Search Again You can click the button on the Quick Tool Bar. The utility will clear all list device servers in the Serial Device Server List Area and re-search again. Dont use this function frequently. The warning message will be pop-up when you double click this button. You can click the button on the Quick Tool Bar. The utility will search serial device server on local LAN. 3.2.3 Manual Appending Using Add IP address to Favorite or Search a Range of IP addresses function, you are able to add one device or group of devices to Favorites. These devices can locate on local network domain or other network domain. C h a p t e r 3 C o n f i g u r a t i o n 25 EKI-1361/EKI-1362 User Manual 3.3 Network Settings This section explains how to configure the network setting of EKI device using this utility so that it can communicate over a network with serial devices. Click on the + before the model name, and the utility will expand the tree structure to show the individual device name. And click on the + before the device name, and the utility will expand the interfaces on this device server. Select the Ethernet interface. (Select Eth1 or Eth2, these are two individual Ethernet ports) MAC address:
The MAC address is for the local system to identify and locate each serial device servers. This MAC address is already set before delivery from factory, hence no need for further configuration. IP address, Subnet Mask, Default Gateway:
You can choose from four possible IP Configuration modes --- Static, DHCP, BOOTP, and DHCP/BOOTP. EKI-1361/EKI-1362 User Manual 26 C h a p t e r 3 C o n f i g u r a t i o n Static IP User defined IP address, Subnet Mask, and Default Gateway. DHCP + Auto-IP DHCP Server assigned IP address, Subnet Mask, Default Gateway, and DNS. BOOTP + Auto-IP BOOTP Server assigned IP address. DHCP + BOOTP + Auto-IP DHCP Server assigned IP address, Subnet Mask, Default Gateway, and DNS, or BOOTP Server assigned IP address. (If the DHCP Server does not respond) DHCP Timeout When EKI device doesn't get response from DHCP server within specific timeout, the EKI device will give up the request and take next action. DNS Setting In order to use DNS feature, you need to set the IP address of the DNS server to be able to access the host with the domain name. The EKI-152X series serial device server provides Primary DNS Server and Secondary DNS Server configuration items to set the IP address of the DNS server. Secondary DNS Server is included for use when Primary DNS server is unavailable. DHCP Advanced Setting When you enabling DHCP protocol to get IP address, it will be waited DHCP server to give IP within DHCP timeout. The default value is 30 seconds. Note! When you have finished the configuration of these settings for each cat-
egory, please press the Apply button in order to make these settings effective on the Serial Device Server. (Will reboot your Serial Device Server immediately) 27 EKI-1361/EKI-1362 User Manual 3.4 Administrator Settings The configuration utility provides several administrator settings for easy management and configuration. Right click the mouse on the device name in the sub-tree of Serial Device Sever List Area, and select these administrator settings. 3.4.1 Locate the Serial Device Server If there are many serial device severs need your management, you may need to identify which unit is correct to configuration on utility. Click Locate to make that units Status LED be steady on and the buzzer will make the beep sound until you click Stop Locate. 3.4.2 Lock the Serial Device Server (Password Protection) The configuration utility provides the Lock Device function to make it more confiden-
tial. You need to set up a password while the first time clicking Lock Device. Be sure to click Reset Device to restart the serial device server and store your setting pass-
word into the memory. EKI-1361/EKI-1362 User Manual 28 C h a p t e r 3 C o n f i g u r a t i o n Click Unlock Device to unlock the serial device sever, and you need to fill in the password you have set up before. If you forgot the password, the only way to solve this problem is to restore the setting of the serial device server to the factory default which will be introduced next section. If you want to disable this function or change the password, click Change Password to change the password to default None (leave the new password and confirm new password columns blank) to disable this function or other password you want to change. Be sure to click Reset Device to restart the serial device sever and store the new password into the memory. 29 EKI-1361/EKI-1362 User Manual 3.4.3 Restore to Factory Default Settings The configuration utility provides this function to let you can restore the serial device server to factory default settings. The confirm message will be pop-up while clicking Restore to Factory Default Settings. If you really want to restore the serial device sever to factory default settings, please click Yes button to continue. Then, please power off the serial device server within ten seconds, after reconnect-
ing the power back, the all setting will be reset to the factory default. If the power remains more than ten seconds, the serial device server will not have any changes. EKI-1361/EKI-1362 User Manual 30 3.4.4 Update Firmware Advantech continually upgrades its firmware to keep up with the ever-expending world of computing. You can use the update firmware function in the utility to carry out the upgrade procedure. Please access Advantechs website: http://www.advan-
tech.com to download the latest version of the firmware. Before update the firmware, make sure that your hosts Network domain is as same as the serial device server or the host can establish the TCP connection to the serial device server. Right Click on the device name and select Update Firmware function. C h a p t e r 3 C o n f i g u r a t i o n Select the firmware file you want to update. 31 EKI-1361/EKI-1362 User Manual Wait for few seconds to process the updating firmware. After downloading the firm-
ware completely, click on the OK button. The serial device server will restart auto-
matically. Note!
Be sure that the host PC Ethernet network domain is as same as the serial device server or the host PC can establish the TCP connection with the serial device server while doing the updating firmware process. EKI-1361/EKI-1362 User Manual 32 Chapter 4 4 Setting COM Redirector 4.1 Setting COM Redirector (Virtual COM port) Advantech COM port mapping software is a serial COM port redirector that creates virtual COM ports and provides access to serial devices connected to Advantech serial device servers. Your serial device applications can communicate with serial devices connected to Advantech serial device servers without software changes. Since the virtual COM ports work like standard Windows COM ports, your application software sees no difference between a local serial device and one connected to a Advantech serial device server. COM redirector utility and Virtual COM port Management utility are integrated into one utility with same GUI. Advantech Serial Device Server Configuration Utility can create all Virtual COM ports using Auto Mapping function. You can map the Virtual COM port by yourself. 4.1.1 Auto Mapping Right click the serial device name on the sub-tree of Device Server List area and select the Auto Mapping function. The serial ports that can be assigned to virtual COM will be shown in this window. Select the serial ports you wish to map or click the <Select All> button and press
<Map Selected Ports> button. The selected serial ports will be mapped to virtual COM ports in sequential order. EKI-1361/EKI-1362 User Manual 34 C h a p t e r 4 S e t t i n g C O M R e d i r e c t o r The COM ports in the Virtual Com Ports listing are now available for use by Win-
dows applications. 35 EKI-1361/EKI-1362User Manual 4.1.2 Manual Mapping Right click the serial device name on the sub-tree of Device Server List area and select the Manual Mapping function. ADAM series, EDG series, and EKI wireless series have only one IP address. Select the serial port on the device server and the host COM that you want to set. Press
<Map it> to establish the virtual COM port on the host. EKI-1361/EKI-1362 User Manual 36 Auto Reconnect Property Sometimes, the connection between Advantech serial device server and HOST is interrupted by network traffic or powered-off by accident. In such a situation, the host has to reconnect to Advantech serial device server. The function "Auto Reconnect" is for this purpose, if the Advantech serial server loses the connection to its host, the COM redirector will try to re-establish the connection while the hosts AP access the virtual COM port. The COM redirector DOES NOT re-establish the connection auto-
matically. When the connection is working again, the host's commands will be auto-
matically received by the Advantech serial device server again. Reconfiguration is not necessary, so this function enhances the reliability of the system. If the function is disabled, the connection can not be re-established again unless the COM redirector or host is restarted. Serial device server has two Ethernet ports. You can select two Ethernet port to establish two Ethernet connections with one virtual COM port. It means that COM redirector will use one connection with the COM port on device server to communicate. If this connection failed, COM redirector will establish another Ethernet connection to communicate with device. The switch time will be 3 seconds ~ 5 seconds depending on the network traffic and host status. C h a p t e r 4 S e t t i n g C O M R e d i r e c t o r If you dont use the redundant function, just select the correct IP address in the IP address 1 field. Note If you set the wrong IP address, COM redirector will still try to connect the device. It might cause the system performance low or other issue. 37 EKI-1361/EKI-1362User Manual 4.1.3 Manual Direct Mapping Virtual COM Port Click the button on the Quick Took area, you can add a target by selecting the Device Type and inputting the IP address without physically connecting the serial device server to the network. 4.1.4 Remove the Virtual COM Port If you want to remove the virtual COM port, you can remove them one by one or group remove ports.
Individually Remove Right click on COM port you have mapped and select Remove This Port. EKI-1361/EKI-1362 User Manual 38 C h a p t e r 4 S e t t i n g C O M R e d i r e c t o r
Group Remove Port Right click on Virtual Com Ports on Device Server List Area and select Group Remove Port, you can choose which ports you want to remove. 39 EKI-1361/EKI-1362User Manual EKI-1361/EKI-1362 User Manual 40 Chapter 5 5 Web-Based Configuration 5.1 Overview EKI series serial device server provides web interface configuration. You can configure EKI device with most popular standard browsers. can be configured through a web interface. By using a standard web browser, you can configure EKI device with the same procedure as with the Windows configuration utility can be used. In the browsers address field, enter the IP Address of your EKI-152X series serial device server. The default IP setting is 10.0.0.1, but you should use the IP which you have previously assigned for this device. Once the IP is entered, you will be presented with the following windows. Note!
Before using the web-based configuration, make sure your host PC Ethernet network IP domain is as same as the serial device server, or it can establish the TCP connection with the serial device server. 5.2 Accessing the Web Page By configuration utility By Windows Internet Explorer EKI-1361/EKI-1362 User Manual 42 C h a p t e r 5 W e b
-
B a s e d C o n f i g u r a t i o n 5.3 System You can change the Device Name and Device Description on this page. You can also enable or disable the Web, Telnet, and SNMP functions. Moreover, you can set the Timezone related setting.
Device Name User can change the default device name to a meaningful name for easy identi-
fication.
Device Description User can place a note about the device in this field for tracking, remind, and etc.
Device Services User can disable the default services to avoid unauthorized access about the device settings.
Device Time User can set the device time for the SNMP trap, mail alarm and etc. That can help identify the time when the event happened. User can set the Time Server to use the NTP function to sync the device time with time server automatically. Or user can set the time manually. Device will keep the time setting even power off. 43 EKI-1361/EKI-1362 User Manual 5.4 Network Configuration Click the Net Configuration and chose either Net 1 or Net 2, there are Net Mode, IP Address, Subnet Mask, Default Gateway and DNS. Enter the corresponding values for your network environment. Remember press Save after fill in all values.
MAC address:
The MAC address is for the local system to identify and locate each serial device servers. This MAC address is already set before delivery from factory, hence no need for further configuration.
IP address, Subnet Mask, Default Gateway:
You can choose from four possible IP Configuration modes --- Static, DHCP, BOOTP, and DHCP/BOOTP. EKI-1361/EKI-1362 User Manual 44
Static IP User defined IP address, Subnet Mask, and Default Gateway.
DHCP + Auto-IP DHCP Server assigned IP address, Subnet Mask, Default Gateway, and DNS.
BOOTP + Auto-IP BOOTP Server assigned IP address.
DHCP + BOOTP + Auto-IP DHCP Server assigned IP address, Subnet Mask, Default Gateway, and DNS, or BOOTP Server assigned IP address. (If the DHCP Server does not respond)
DHCP Timeout When EKI device doesn't get response from DHCP server within specific time-
out, the EKI device will give up the request and take next action.\
DNS Setting In order to use DNS feature, you need to set the IP address of the DNS server to be able to access the host with the domain name. The EKI-152X series serial device server provides Primary DNS Server and Secondary DNS Server config-
uration items to set the IP address of the DNS server. Secondary DNS Server is included for use when Primary DNS server is unavailable.
DHCP Advanced Setting When you enabling DHCP protocol to get IP address, it will be waited DHCP server to give IP within DHCP timeout. The default value is 30 seconds. Note!
All new configurations will take effect after rebooting. The reboot func-
tion is located on the main menu of the Web Configuration. 5.5 Wireless Configuration You may onfigure the detail wireless configuration in this page. C h a p t e r 5 W e b
-
B a s e d C o n f i g u r a t i o n 45 EKI-1361/EKI-1362 User Manual
Mode User can set EKI as Client mode to connect EKI device to a wireless access point or set EKI as Ad-hoc mode to connect with other wireless device directly without wireless access point.
Site survey User can use this function to discovery the wirelees access point near EKI device. Sometimes, due to the wireless access point setting and environment issue, the specific wireless access point may not be listed in the result. User can try to refresh the list several times.
SSID When using Client mode, user can specify the SSID that EKI device should con-
nect to; When using Ad-hoc mode, user can specify the SSID and channel that forms a ad-hoc network.
Country code Differet country code specify different selectable channels. User should choose the correct corresponding country code to avoid breaking the local law. EKI-1361/EKI-1362 User Manual 46
Encryption User can choose using wireless communication without encryption, or choose with "WEP", "WPA/WPA2-Personal", or "WPA/WPA2-Enterprise" that can use standard encryption method to protect the data.
WEP Wired Equivalent Privacy (WEP) is a security algorithm for IEEE 802.11 wireless networks. When using WEP encryption, user should also choose the authenti-
cation algorithm, key index, key format and fill in the key content repspectively. C h a p t e r 5 W e b
-
B a s e d C o n f i g u r a t i o n 47 EKI-1361/EKI-1362 User Manual
WPA/WPA2-Personal, WPA/WPA2-Enterprise The main difference between WPA/WPA2-Personal and WPA/WPA2-Enterprise is the authentication method. WPA/WPA2-Enterprise uses additional certifica-
tion to identify the specific device. User should provide the extra certification and private key files. If using WPA/WPA2 encryption, user should also choose which EAP method is using with: TLS, TTLS, or PEAP. User should also provide the relative parameters: Man-
agement frame protection, Identity, Password, Inner Authertication. 5.6 Port Configuration There are Basic, Operation Mode, and Advanced Setting in the serial port configuration. For more detailed information for setting, please refer to chapter 3.4 and chapter 3.5. EKI-1361/EKI-1362 User Manual 48 C h a p t e r 5 W e b
-
B a s e d C o n f i g u r a t i o n 5.6.1 Basic Port Configuration
Type The EKI-152X series serial device server offers three kinds of serial interfaces, RS-232, RS-485 and RS-422. User can use any of the three serial interfaces according to users requirements.
Baud Rate User can choose the regular baud rate from the drop down list or key in any par-
ticular baud rate manually.
Parity The EKI serial device server provides five options for parity: None, Odd, Even, Space, and Mark.
Data Bits The EKI serial device server provides four options for data bits: 5, 6, 7, and 8.
Stop Bits The EKI serial device server provides three options for stop bits: 1, 1.5, and 2.
Flow Control The EKI serial device server provides four options for flow control: None, XON/
XOFF, RTS/CTS, and DTR/DSR. 5.6.2 Operation Mode 5.6.2.1 Virtual COM Mode The EKI serial device server extends traditional COM ports of a PC to Ethernet access. Through Ethernet networking, users can control and monitor remote serial devices and equipment over LAN or WAN. The EKI device server comes with a COM port redirector (Virtual COM driver) that transmits all serial signals intact. This means that your existing COM-based software can be preserved, without modifying to fulfill the needs. The Virtual COM mode allows user to continue using RS-232/422/485 serial communications software that was written for pure serial communication appli-
cations. The EKI series comes with COM port redirector (virtual COM driver) that work with Window 2000/XP/Vista(X86) systems. The driver establishes a transparent con-
49 EKI-1361/EKI-1362 User Manual nection between host and serial device by mapping the IP of the EKI-152X seriesse-
rial device server serial port to a local COM port on the host computer. The EKI series provides Multi-access function through Ethernet connection path. Allow the maximum of 5 connections to open one serial port simultaneously. In this mode, all connection has to use the same serial setting. If one serial setting of these connections is different from others, the data communication may operate incorrectly.
Host Idle Timeout The Host Idle Timeout setting monitors the connection between the host and the device. If the Host Idle Timeout setting time is reached, the device server will release the resources allocated to the port mapping. This prevents a stalled host from affecting the connective device. The EKI device provides Multi-access function through Ethernet connection path. Allow the maximum of 5 connections to open one serial port simultane-
ously. In the mode, all connection has to use the same serial setting. If one serial setting of these connections is different from others, the data communica-
tion may operate incorrectly. There are two operating mode of Multi-access function. One is Normal mode;
another is Round-Robin mode.
Normal mode Disabling Response Timeout parameter, the EKI device will operate in normal mode. When multiple hosts open the serial port simultaneously, the EKI device only offers control ability for the first connected host and provides data commu-
nication function for others. Each serial port supports up to five simultaneous connections, so multiple hosts can transmit/receive data to/from the same serial port simultaneously. Every host can transmit data to the same serial port, and the EKI device will also transmit data to every hosts. When the multiple hosts transmit data to the same serial port at the same time, the received data from EKI-1361/EKI-1362 User Manual 50 Ethernet and the outputs of serial port are mixed. When the EKI device receives data from serial port, the data will also be transmitted to the connected hosts simultaneously.
Round-Robin mode:
Enabling Response Timeout parameter, the EKI device will operate in Round-
Robin mode. Each serial port supports up to five simultaneous connections, so multiple hosts can transmit/receive data to/from the same serial port simultane-
ously. Every host can transmit data to the same serial port simultaneously, but the EKI device will process the data communication in order. The EKI device will process the first hosts request and reply the response to the first host. The EKI device serial device server can determine the end of the serial acknowledge-
ment via response timeout. When EKI device serial device server receives noth-
ing from serial port after the setting of response timeout, the device will reply the acknowledgement to the host and then process the next hosts request. While the connected hosts are more and Response Timeout is long, the process time is much longer. Frame Break is a very import parameter for Round Robin mode. This parameter is the smart way to reduce inefficient waiting time and the EKI device can trans-
mit data more efficiently. Disabling the Frame Break function, the EKI device will wait Response Timeout period, whether the device have transmitted the data. During this period, the commands from hosts will be queued and the EKI device just processes this command. Enabling Frame Break, if the serial port idle is longer than the Frame Break period, the EKI device will assume the communi-
cation is completed and continue the next hosts query. This is an efficient way to reduce the waiting time and improve the performance. 5.6.2.2 Data Mode (USDG Mode) The EKI device can be Data server or Data client either. Both operations support TCP and UDP protocol. The EKI device makes your serial devices behave just like networking devices. You can issue commands or transmit data from serial devices, which connected to the EKI device, to any devices that are connected to the Internet. The EKI device allows most 5 host PCs accessing data simultaneously via polling networking architecture. You can use it according to your application. If you want to access the EKI device, you must ascertain your application software supports stan-
dard networking application programming interface (API) such as: WinSock Socket. You might select USDG Mode as the following figure to change the mode of the port to TCP server/client or UDP mode. C h a p t e r 5 W e b
-
B a s e d C o n f i g u r a t i o n 51 EKI-1361/EKI-1362 User Manual
Protocol The EKI device provides TCP/IP and UDP two protocols. In settings, you can choose either TCP mode or UDP mode according to your application.
Data Listen Port The TCP/UDP port number represents the source port number, and the number is used to identify the channel for remote initiating connections. Range: 1024-
65533. If an unknown caller wants to connect to the system and asks for some services, they need to define the TCP/UDP port to carry a long-term conversa-
tion. Each node on a TCP/IP network has an IP address, and each IP address can allow connections on one or more TCP port. The well known TCP ports are those that have been defined; for example, port 23 is used for Telnet connec-
tions. There are also custom sockets that users and developers define for their specific needs. The default TCP/UDP port of the EKI device is 5300. The exam-
ple initial 5300 is System Port, and 5301 is Data Port. But users can adjust them by one's preference or application. Each port has its own data listen port to accept connected request of other net-
work device. So, the data listen port cant be set the same value. You can trans-
mit/receive data to/from device via the data listen port.
Command Listen Port Each port has its own command listen port to accept connected request of other network device. So, the command listen port cant be set the same value. You can use AT command to change the port setting via the command listen port. The Command Listen Port should be different from the Data Listen port.
Data Idle Timeout The default is 60 seconds. If you want to keep connection continually, you can disable the Data Idle Timeout. Data idle Time is the time period in which the device waits for data. If the EKI device does not receive data over an estab-
lished idle time, the EKI device will disconnect temporarily. When the data EKI-1361/EKI-1362 User Manual 52 C h a p t e r 5 W e b
-
B a s e d C o n f i g u r a t i o n comes to the EKI device, it will reconnect automatically. Users do not need to reconnect.
Enable Time Sharing The EKI device provides Multi-access function through Ethernet connection path. Allow the maximum of 5 connections to open one serial port simultane-
ously. In the mode, all connection has to use the same serial setting. If one serial setting of these connections is different from others, the data communica-
tion may operate incorrectly. There are two operating mode of Multi-access function. One is Normal mode;
another is Round-Robin mode.
Normal Mode Disabling Response Timeout parameter, the EKI device will operate in normal mode. When multiple hosts open the serial port simultaneously, the EKI device only offers control ability for the first connected host and provides data commu-
nication function for others. Each serial port supports up to five simultaneous connections, so multiple hosts can transmit/receive data to/from the same serial port simultaneously. Every host can transmit data to the same serial port, and the EKI device will also transmit data to every hosts. When the multiple hosts transmit data to the same serial port at the same time, the received data from Ethernet and the outputs of serial port are mixed. When the EKI device receives data from serial port, the data will also be transmitted to the connected hosts simultaneously.
Round-Robin Mode Enabling Response Timeout parameter, the EKI device will operate in Round-
Robin mode. Each serial port supports up to five simultaneous connections, so multiple hosts can transmit/receive data to/from the same serial port simultane-
ously. Every host can transmit data to the same serial port simultaneously, but the EKI device will process the data communication in order. The EKI device will process the first hosts request and reply the response to the first host. The EKI device serial device server can determine the end of the serial acknowledge-
ment via response timeout. When EKI device serial device server receives noth-
ing from serial port after the setting of response timeout, the device will reply the acknowledgement to the host and then process the next hosts request. While the connected hosts are more and Response Timeout is long, the process time is much longer. Frame Break is a very import parameter for Round Robin mode. This parameter is the smart way to reduce inefficient waiting time and the EKI device can trans-
mit data more efficiently. Disabling the Frame Break function, the EKI device will wait Response Timeout period, whether the device have transmitted the data. During this period, the commands from hosts will be queued and the EKI device just processes this command. Enabling Frame Break, if the serial port idle is longer than the Frame Break period, the EKI device will assume the communi-
cation is completed and continue the next hosts query. This is an efficient way to reduce the waiting time and improve the performance.
Auto Connect Peer IP If enabling this option, EKI device will connect to TCP/IP which are set at Peers page automatically after boot up.
Peer Number Set the number of network device which you want to connect. You can set max-
imum sixteen network devices which you want to connect. You need to fill out the IP Address and Port (including local port and peer port) of network devices which you want to connect. 53 EKI-1361/EKI-1362 User Manual
Data Pack Data pack means you can set condition of receiving data from serial port to be a package according to your application. There are four options to set the data packing: by data size (Byte), by time interval (ms), by character timeout (4 Bytes), or by end of character. 5.6.2.3 USDG Control Mode In controlling mode, the EKI device presents a modem interface to the attached serial device: it accepts AT-style modem commands to connect/disconnect to other net-
working device. If you want serial device running application program to connect/dis-
connect to different devices dynamically, you can use controlling mode. The Control mode provides three kinds of modem AT-style commands. The serial devices can use these commands to control the EKI device to connect/disconnect to remote networking device. Thus, intelligent serial devices such as standalone PLC will send/receive data to/from devices one by one via Ethernet. Please refer to the USDG Data Mode to setup the Data Listen Port, Command Listen Port, and Data Idle Timeout.
Hangup Character The default character is +. After you have connected to another serial device via EKI device, you may need to disconnect. Then you can use the command
"+++" to disconnect. To do this leaves your keyboard idle (don't press any keys) for at least several seconds, then press + three times. You can set Guard Time" to define the idle time. Be sure that you have to press + over the idle time.
Guard Time The default value is 1000 ms. Example: <Guard Time>+++<Guard Time>
EKI-1361/EKI-1362 User Manual 54 C h a p t e r 5 W e b
-
B a s e d C o n f i g u r a t i o n Control Mode is designed for use with legacy operating systems, such as MS-
DOS, that do not support TCP/IP Ethernet. By connecting one of EKIs serial ports to the MS-DOS computers serial port, it is possible to use legacy software originally designed to transmit data via modem, but now transmit the data over the Ethernet.
Dial-in (Use TCP connect to serial port of EKI) EKI listens for a TCP/IP connection request from the remote host. when a TCP connection is coming, there will have prompt string "RING" shows on serial port site. After the system prompting the "RING" string, user can use "ATA" com-
mand to accept the connection or just ignore it. After accepted the connection, EKI will enter data mode.
Dial-out (From serial port connect to specific TCP host target) User can user the AT Comand "ATD <IP>#<TCP port>" to connect to a specific TCP target host from serial port. when the TCP connection is accepted by the remote host, EKI will show "CONNECT" string to serial port and enter data mode.
Disconnect from serial port When EKI is in data mode, user can type the hangup character triple times, such as "+++". EKI will shut down the TCP connection and back to command mode, and shows NO CARRIER to indicate the connection has been shut down.
Disconnect from remote TCP connection
When EKI shows "NO CARRIER" on serial port, it means the TCP connection has been shut down. EKI will back to command mode automatically. Note!
The +++ command cannot be divided. The + character can be changed in Hang-up Character, and the guard time, which prefixes and suffixes the +++ in order to protect the raw data, can be changed in Guard Time (ms). See picture. AT Commands EKI supports the following common AT commands used with a typical modem:
AT command Description ATA ATD ATE ATH ATZ AT&F Answer Dial up the IP address#Port No. ATE0=Echo OFF ATE1=Echo ON (default) On-hook Reset and Recall users settings Restore factorys Default settings 55 EKI-1361/EKI-1362 User Manual Example 1 (Local connect to remote) Example 2 (Remote connect to local) EKI-1361/EKI-1362 User Manual 56 5.7 Monitor You can monitor the serial ports settings, statistic, and the connected IP address by click on Monitor function on the main menu. C h a p t e r 5 W e b
-
B a s e d C o n f i g u r a t i o n 57 EKI-1361/EKI-1362 User Manual 5.8 Auto Warning (Alarm) You can set the e-mail server and SNMP Trap server in the Setting page, and set the event type in the Event page. 5.8.1 Email Alert Consult your ISP or Network Administrator for the proper SMTP mail server settings. The auto warning functions may not work properly without proper settings. EKI-1361/EKI-1362 User Manual 58 C h a p t e r 5 W e b
-
B a s e d C o n f i g u r a t i o n 5.8.2 SNMP Trap You need to set the proper IP address of SNMP Trap Server. And choose the Trap Version; there are SNMP v1 and SNMP v2c options. 5.8.3 System Event
Cold Start This refers to starting the system from power off. When performing a cold start, the EKI device will send an e-mail, or send a SNMP trap after success reboot-
ing.
Warm Start This refers to restarting the system without turning the power off. When perform-
ing a warm start, the EKI device will send an e-mail, or send a SNMP trap after restarting the system.
Authentication failure The user types a wrong password from Console or Administrator. When authen-
tication failure occurs, the EKI device will send an e-mail, or send a SNMP trap.
IP Change The user changes the EKI devices IP address. When the IP address changes, the EKI device will send an e-mail, or send a SNMP trap after restarting the sys-
tem.
Password Change The user changes the EKI devices password. When the password changes, the EKI device will send an e-mail, or send a SNMP trap after restarting the system.
Ethernet 1 Down The Ethernet 1 port has link failure condition. When the Ethernet 1 links fail, the EKI device will send an e-mail, or send a SNMP trap immediately.
Ethernet 2 Down The Ethernet 2 port has link failure condition. When the Ethernet 2 links fail, the EKI device will send an e-mail, or send a SNMP trap immediately. 59 EKI-1361/EKI-1362 User Manual 5.8.4 Serial Port Event
DCD Change The DCD (Data Carrier Detect) signal has changed, also indicating that the modem connection status has changed. For example, a DCD change to high also means Connected between local modem and remote modem. If the DCD signal changes to low, it also means that the connection line is down. When the DCD signal changes, the EKI device will send an e-mail, or send a SNMP trap.
DSR Change The DSR (Data Set Ready) signal has changed, also indicating that the data communication equipments power is off. For example, a DSR change to high also means that the DCE is powered ON. If the DSR signal changes to low, it also means that the DCE is powered off. When the DSR signal changes, the EKI device will send an e-mail, or send a SNMP trap. Note!
All new configurations will take effect after rebooting. The reboot func-
tion is located on the main menu of the Web Configuration. 5.9 Change Password You can change the serial device server password on here:
If you have set a password via the configuration utility or Telnet or serial console, when you access the web configuration, you need to key in the password. Do not need to enter the user name in the dialog. EKI-1361/EKI-1362 User Manual 60 If you want to disable the password protection, just change the password to the default None (leave the new password column blank), Be sure to press the Save button and reboot the serial device server to make the change effective. 5.10 Import/Export Device Settings You can Import or Export the serial device server all setting as the .conf file format. C h a p t e r 5 W e b
-
B a s e d C o n f i g u r a t i o n 61 EKI-1361/EKI-1362 User Manual 5.11 Reboot The configuration will take effect after clicking Save button. But all configurations will save to flash memory after this reboot step. Press the Reboot button and the system will give a reset response. It will take a few seconds to reconnect with the new values. EKI-1361/EKI-1362 User Manual 62 Chapter 6 6 Telnet Configuration 6.1 Overview The purpose of the Console Configuration is to help you manage your device in con-
sole mode. One of the main functions of the console mode is to change the web con-
figuration login password. You can use terminal software like Hyper Terminal, Telix and other related terminal software. 6.2 Telnet Console Create a new connection You can create a new Telnet connection and assign a connection name for the con-
sole configuration. Input the IP address Confirm that the Telnet console configuration works ok. Be sure that your host PC Ethernet network IP domain is as same as the EKI-152X series serial device server, and the Telnet TCP port number is 23. EKI-1361/EKI-1362 User Manual 64 Connecting Success After connection the serial device server in Telnet console mode, you can see the welcome message in the Hyper Terminal Windows. C h a p t e r 6 l T e n e t C o n f i g u r a t i o n 6.3 Command List Table 6.1: Console Command List Command Function Description system port portadv mvcom mctrl mdata net Show or configure the system information Show or configure the serial ports information Show or configure the serial ports advanced settings Show or configure the serial ports in Virtual COM mode Show or configure the serial ports in Control mode (USDG) Show or configure the serial ports in Data mode (USDG) Show or configure the Ethernet ports settings password Set or change the password apply exit help Write settings to the flash memory and reboot the system immediately Terminate the shell session Display help information of command list
<Tab> <Tab>
Display help information of command list import export monitor alarm time service Import the serial device server all settings Export the serial device server all settings Monitor the serial ports status Show or configure the auto warning functions including mail alarm and SNMP alarm Show or configure the time information Enable or disable the web, Telnet and SNMP functions wireless Show or configure the wireless settings or informations 65 EKI-1361/EKI-1362 User Manual wirelessadv Show or configure the advanced wireless settings or informations Help You might type the help command or press <Tab> twice to show the supported command list.
[Usage] help
[Function] Display help information of command list You might use help command to show the usage of all commands.
[Usage] help [command]
[Function] Show the usage of command EKI-1361/EKI-1362 User Manual 66 C h a p t e r 6 l T e n e t C o n f i g u r a t i o n System
[Usage] system
[Function] Show firmware version, device name and description
[Usage] system
[Function] Show current device status and information
[Usage] system name XXXX
[Function] Set current device name [XXXX: maximum length 31 bytes]
[Usage] system desc XXXX
[Function] Set current device description [XXXX: maximum length 127 bytes]
Port Port is the command to show all serial ports information and configure the serial ports settings. 67 EKI-1361/EKI-1362 User Manual
[Usage] port nn or port all
[Function] Show the nnth port or all ports information
[Usage] port nn desc XXXX
[Function] Set the nnth ports description [XXXX: maximum length 127 bytes]
EKI-1361/EKI-1362 User Manual 68
[Usage] port nn||all type 232|422|485 flow 0|1|2|3
[Function] Set serial ports type and flow control Flow 0: None Flow 1: XOn/XOff Flow2: RTS/CTS Flow3: DTR/DSR
[Usage] port nn|all baud XXXX parity n|e|o|m|s data 5|6|7|8 stop 1|1.5|2
[Function] Set the serial ports baud rate, parity, data bits, and stop bits. Acceptable baud rate: 50, 75, 110, 150, 300, 600, 1200, 1800, 2400, 4800, 7200, 9600, 14400, 19200, 38400, 57600, 115200, 230400, 460800, and 921600 Parity n: None Parity e: Even Parity o: Odd Parity m: Mark Parity s: Space
[Usage] port nn|all mode vcom|ctrl|data
[Function] Set the serial ports as virtual COM mode, control mode, or data mode mvcom Show and setup the VCOM mode C h a p t e r 6 l T e n e t C o n f i g u r a t i o n 69 EKI-1361/EKI-1362 User Manual
[Usage] mvcom
[Function] Show all serial ports mode and related information
[Usage] mvcom nn|all
[Function] Set the nnth or all serial ports as the Virtual COM mode
[Usage] mvcom nn|all idleto XX
[Function] Set the nnth or all serial ports host idle timeout (S)
[Usage] mvcom nn|all respto XX framebk XX
[Function] Set the nnth or all serial ports response timeout and frame break mctrl Show and setup the Control mode
[Usage] mctrl
[Function] Show all serial ports mode and related information
[Usage] mctrl nn|all
[Function] Set the nnth or all serial ports as the Control mode
[Usage] mctrl nn|all idleto XX guardt XX hangchr XX
[Function] Set the nnth or all serial ports data idle timeout, guard time and hang character EKI-1361/EKI-1362 User Manual 70 C h a p t e r 6 l T e n e t C o n f i g u r a t i o n mdata Show and setup the Data mode
[Usage] mdata
[Function] Show all serial ports mode and related information
[Usage] mdata nn|all
[Function] Set the nnth or all serial ports as the Data mode
[Usage] mdata nn|all protocol TCP|UDP
[Function] Set the nnth or all serial ports transmit protocol as TCP or UDP
[Usage] mdata nn|all idleto XX lsport XXXX atport XXXX
[Function] Set the nnth or all serial ports data idle timeout, listen port, and AT com-
mand port
[Usage] mdata nn|all respto XX framebk XX
[Function] Set the nnth or all serial ports response timeout and frame break
[Usage] mdata nn|all peernum 1|2|3|4|5|6|7|8|9|10|11|12|13|14|15|16 peer XX.XX.XX.XX:ppp
[Function] Set the peer IP address and port for receive data 71 EKI-1361/EKI-1362 User Manual net Show and setup the Ethernet port configuration
[Usage] net 1|2
[Function] Show the first or second Ethernet port status and information
[Usage] net 1|2 mode static|dhcp|boot|all
[Function] Set the network operating mode
[Usage] net 1|2 ip XX.XX.XX.XX netmask XX.XX.XX.XX gw XX.XX.XX.XX
[Function] Set IP address, subnet mask, and default gateway
[Usage] net 1|2 dns auto|specific
[Usage] net 1|2 dns1 XX.XX.XX.XX
[Usage] net 1|2 dns2 XX.XX.XX.XX
[Function] Set the DNS function EKI-1361/EKI-1362 User Manual 72 C h a p t e r 6 l T e n e t C o n f i g u r a t i o n password
[Usage] password new XXXX
[Function] Set new password [XXXX: maximum 31 characters]
[Usage] password old XXXX new XXXX
[Function] Confirm the old password and set a new password apply
[Usage] apply
[Function] Save the settings to the flash memory and reboot the system immediately exit
[Usage] exit
[Function] Terminate the shell session import/export
[Usage] import
[Function] Import the serial device server settings file
[Usage] export
[Function] Export the serial device server settings file 73 EKI-1361/EKI-1362 User Manual monitor Show the serial ports settings, statistic, and connected IP address
[Usage] monitor port 1|2||16 setting
[Function] Monitor the serial ports settings
[Usage] monitor port 1|2||16 statistic
[Function] Monitor the serial ports statistic
[Usage] monitor port 1|2|16 ip
[Function] Monitor the serial ports connected IP address EKI-1361/EKI-1362 User Manual 74 alarm Show or configure the auto warning function For more detailed setting for auto warning, please refer to chapter 3.7 time Show or configure the time information C h a p t e r 6 l T e n e t C o n f i g u r a t i o n 75 EKI-1361/EKI-1362 User Manual
[Usage] time
[Function] Show the current time information
[Usage] time YYYYMMDDhhmmss
[Function] Modify the current time information
[Usage] time timezone -12||0|1||12
[Function] Set the current timezone configuration
[Usage] time daylight on|off begin MMDD end MMDD
[Function] Set the current time daylight saving configuration
[Usage] time ntp XXXX
[Function] Set the NTP timeserver [XXXX: time server]
service Enable or disable some extra service
[Usage] service web enable|disable
[Function] Enable or disable the web-based configuration
[Usage] service telnet enable|disable
[Function] Enable or disable the telnet console
[Usage] service SNMP enable|disable
[Function] Enable or disable the SNMP function EKI-1361/EKI-1362 User Manual 76 C h a p t e r 6 l T e n e t C o n f i g u r a t i o n wireless Show or configure the wireless settings or informations
[Usage] wireless
[Function] Show or configure the wireless settings or informations
[Usage] wireless ssid XXXX
[Function]Set SSID as XXXX
[Usage] wireless country us|de|fr|es|jp|kr|cn channel 0|1||14
[Function] Set country code and channel. us - United States de Germany fr France es - Spain jp Japan kr Korea cn - China channel 0 - Auto
[Usage] wireless encryption none|wep|wpa-psk|wpa-enterprise
[Function] Set encryption type.
[Usage] wireless wepauth on|off
[Function] Set WEP authentication algorithm.
[Usage] wireless wepidx 0|1|2|3
[Function] Set WEP key index.
[Usage] wireless wepkey asc|hex XXXX
[Function] Set WEP key as XXXX in specific format
[Usage] wireless wpakey XXXX
[Function] Set WPA-PSK key as XXXX
[Usage] wireless wpaeap tls|ttls|peap
[Function] Set WPA-Enterprise EAP method.
[Usage] wirelesswpa11w 0|1|2
[Function] Set WPA-Enterprise management frame protected. 0 Disable 1 Optional 2 Required
[Usage] wireless wpaid XXXX
[Function] Set WPA-Enterprise identity as XXXX. 77 EKI-1361/EKI-1362 User Manual
[Usage] wireless wpapw XXXX
[Function] Set WPA-Enterprise as XXXX.
[Usage] wireless wpaphase mschapv2|md5
[Function] Set WPA-Enterprise inner authentication.
[Usage] wireless capw XXXX
[Function] Set private key as XXXX.
[Usage] wireless cacert
[Function] import the CA certification from host PC to device.
[Usage] wireless caclient
[Function] import the Client certification from host PC to device.
[Usage] wireless cakey
[Function] import the private key from host PC to device. wirelessadv Show or configure the wireless advanced settings or information
[Usage] wirelessadv
[Function] Show device wireless advance informations.
[Usage] wirelessadv rts 256||2347
[Function] Set RTS threshold.
[Usage] wirelessadv frag 256||2346
[Function] Set fragmentation threshold.
[Usage] wirelessadv roaming on|off
[Function] Enable/disable Roaming.
[Usage] wirelessadv rssi 10||95
[Function] Set connection quality monitor RSSI threshold.
[Usage] wirelessadv preamble short|long
[Function] Set preamble.
[Usage] wirelessadv scanint_high 10||600
[Function] Set scan interval when received signal strength is better than RSSI threshold.
[Usage] wirelessadv scanint_low 10||600
[Function] Set scan interval when received signal strength is worse than RSSI threshold. EKI-1361/EKI-1362 User Manual 78 Appendix A APin Assignments A.1 Pin Assignments A.1.1 RS-232 Pin Assignments Pin #
Description 1 2 3 4 5 6 7 8 9 DCD Rx Tx DTR GND DSR RTS CTS RI A.1.2 RS-422/485 Pin Assignments A.1.2.1 1. RS-422 Pin #. Description 1 4 5 7 9 Tx-
Tx+
GND Rx+
Rx-
A.1.2.2 2. RS-485 Pin #
Description 1 4 5 Data-
Data+
GND EKI-1361/EKI-1362 User Manual 80 Appendix B BList of Known TCP and UDP Port Numbers B.1 List of Known TCP and UDP Port Numbers Port 5048 5058 5202 9999 22 23 25 53 67 68 80 123 161 162 443 502 514 546 547 Protocol
(TCP/UDP)
(TCP/UDP)
(TCP)
(TCP)
(TCP)
(TCP)
(TCP) Service Configuration Utility Configuration Utility VCOM/RVCOM Firmware Download SSH Telnet SMTP(Mail Client)
(TCP/UDP) DNS
(UDP)
(UDP)
(TCP)
(TCP)
(UDP)
(TCP/UDP)
(TCP)
(TCP)
(UDP)
(TCP/UDP)
(TCP/UDP) BOOTP Server/DHCP BOOTP Client/DHCP Web Interface/HTTP NTP SNMP SNMP Trap HTTPS Modbus/TCP(Default) Syslog DHCPv6 Client DHCPv6 Server EKI-1361/EKI-1362 User Manual 82 A p p e n d x B i i L s t o f K n o w n T C P a n d U D P P o r t N u m b e r s 83 EKI-1361/EKI-1362 User Manual www.advantech.com Please verify specifications before quoting. This guide is intended for reference purposes only. All product specifications are subject to change without notice. No part of this publication may be reproduced in any form or by any means, electronic, photocopying, recording or otherwise, without prior written permis-
sion of the publisher. All brand and product names are trademarks or registered trademarks of their respective companies. Advantech Co., Ltd. 2013 Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.
15.21 FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. 15.19 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC RF Radiation Exposure Statement:
1. This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. 2. This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body.
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2014-03-11 | 2412 ~ 2462 | DTS - Digital Transmission System | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2014-03-11
|
||||
1 | Applicant's complete, legal business name |
Advantech Co Ltd
|
||||
1 | FCC Registration Number (FRN) |
0013543681
|
||||
1 | Physical Address |
No. 1, Alley 20, Lane 26, Rueiguang Road
|
||||
1 |
Taipei, N/A 114
|
|||||
1 |
Taiwan
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
c******@telefication.com
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
M82
|
||||
1 | Equipment Product Code |
EKI1362
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
L****** H****
|
||||
1 | Telephone Number |
886-2******** Extension:
|
||||
1 | Fax Number |
886-2********
|
||||
1 |
L******@advantech.com.tw
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
Compliance Certification Services Inc. Hsinchu Lab
|
||||
1 | Name |
W******** C******
|
||||
1 | Physical Address |
Taiwan
|
||||
1 | Telephone Number |
886-3********
|
||||
app s | Non Technical Contact | |||||
1 | Firm Name |
Compliance Certification Services Inc. Hsinchu Lab
|
||||
1 | Name |
W******** C******
|
||||
1 | Physical Address |
Taiwan
|
||||
1 | Telephone Number |
886-3********
|
||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DTS - Digital Transmission System | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Serial Device Server | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Power output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Device includes 20/40MHz bandwidths. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Compliance Certification Services Inc.
|
||||
1 | Name |
W**** C********
|
||||
1 | Telephone Number |
886-3******** Extension:
|
||||
1 | Fax Number |
886-3********
|
||||
1 |
w******@ccsrf.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | MO | 2412.00000000 | 2462.00000000 | 0.4000000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC