Tablet PC AIM-68S Series Startup Manual AIM-68S Appearance Description of Parts Left: Front View Right: Rear View For more information on this and other Advantech products, please visit our website at:
http://www.advantech.com For technical support and service, please visit our support website at:
http://support.advantech.com This manual is for AIM-68S Series First Edition Jan 2024 A: Power Button B: Volume Button C: Barcode (Optional) D: Programmable Button E: Front Camera F: Light Sensor G: Speaker H: Docking Pogo (USB3.0) I: Power LED J: Barcode LED K: Audio Jack (Headset Combo) L: USB 3.1 Type-A M: USB 3.1 Type C N: NFC O: Rear Camera with LED Flash P: Battery Cover Q: Add On Extension Pogo Easy Setup Power On Computer 1. 2. 3. 4. 5. Model: AIM-68S Rating 20 Vdc / 3.25 A This product is intended to be supplied by a UL Listed Power Adapter (Delta/ ADP-65SD B) for model AIM-68S. Please contact Advantech for further information and assistance. Push the Power button (A on description of parts.) for 3 seconds to start the computer. The product is equipped with a 10.1 Capacitive Touch Panel. Use finger to touch the following Active Area to operate the computer. The product is equipped with two LED indicator for power status and barcode scanning status. Power LED:
a) The orange LED blinks when internal battery capacity is below 10% to warn the user to charge. b) The Blue LED lights up when internal battery is being charged. c) The Green LED lights up when internal battery is full. Barcode LED: When built barcode scan successfully, BCR LED will flash red color, 6. While the computer is running, push the power button for 1 second will disable LCD backlight for power saving. Push the power button again will enable the backlight again; press the power button for 5 seconds while computer is running, the system will shut down. 7. Environment:
Operating Temperature : -10C ~ +50 C Operating Humidity : 10% ~ 90%@40C non-
Storage/Transportation Temperature :
condensed
-20C ~ +60C Storage/Transportation Humidity :
10% ~ 95%@40C non-condensed Humidity consider to 25C, 48 hrs Number and type of Means of Protection :
MOPP Altitude 3000m Atmospheric pressure 700-1013 hPa (for operating); 500-1060 hPa (for Storage/Transportation) IP level : IPX0 8. There will be ADVANTECH logo upside down while first boot up. This scenario will be disappear after 2nd boot up and wont influence functions and usage. Maintenance If encounter any ofsystem failure or serious incident in relation to device, please report to the manufacturer or local agent. Battery Caution CAUTION!
Danger of explosion if battery is incorrectly replaced. Replace only with the same type recommended by the manufacturer, discard used batteries according to the manufacturer's instructions.
(1) leaving a BATTERY in an extremely high temperature surrounding environment that can result in an EXPLOSION or the leakage of flammable liquid or gas
(2) a BATTERY subjected to extremely low air pressure that may result in an EXPLOSION or the leakage of flammable liquid or gas. Attention : Danger d'explosion si la batterie est inexactement remplace. Remplacez seulement avec la mme chose ou le type recommand par le fabricant, jettent les batteries utilises instructions de s selon fabricant des'. Mistreat the battery used in this device may present a risk of fire or chemical burn. Do not attempt to disassemble the computer or its accessories. Only qualified personal is allowed to replace the battery. Do not dispose batteries in a fire and check with local authorities for disposal instructions. AIM-68S can only be equipped with standard battery pack with Advantech, AIM-68S-BAT, 4010mAh, Li-ion Battery. Use of another battery may present a risk of fire or explosion. Battery Charge Notice It is important to consider the environment temperature whenever you are charging the Li-ion battery pack. The process is more efficient at normal room temperature or slightly cooler. It is essential that you charge batteries within the stated range of 0C to 40C. Charging batteries outside of the specified range could damage the batteries and shorten their charging life cycle. Storage and Safety Notice Although charge Li-ion batteries may be left unused for several months, their capacity may be depleted due to the buildup of internal resistance. If this happens they will require recharging prior to use Li-ion batteries may be stored at temperatures between
-20C to 60C, however they may be depleted more rapidly at the high end of this range. It is recommended to store AIM-68S within normal room temperature ranges. Warnings, Cautions and Notes Warning!
Caution!
A WARNING statement provides important information about a potentially hazardous situation which, if not avoided, could result in death or serious injury. Avertissement!
Une dclaration d'AVERTISSEMENT fournit des informations importantes sur une situation potentiellement dangereuse qui, si elle n'est pas vite, pourrait entraner la mort ou des blessures graves. A CAUTION statement provides important information about a potentially hazardous situation which, if not avoided, may result in minor or moderate injury to the user or patient or in damage to the equipment or other property. Une dclaration de MISE EN GARDE fournit des informations importantes sur une situation potentiellement dangereuse qui, si elle n'est pas vite, peut entraner des blessures mineures ou modres pour l'utilisateur ou le patient ou endommager l'quipement ou d'autres biens. Attention!
A NOTE provides additional information intended to avoid inconveniences. Details fo preparatory treatment or disposal Installation is only to be carried out by manufacturer authorized and trained personnel. Calibration the device
We suggest to send back to supplier for annually check. Safety Instructions 1. Strictly follow these instructions for use; please read these safety instructions carefully. 2. Keep this user manual for later reference; any use of the product requires full understanding and strict observation of all portions of these instructions. Observe all. 3. Repair of the device may also only be carried out by trained service personnel. 4. Advantech recommends that a service contract be obtained with Advantech Service and that all repairs also be carried out by them. Otherwise the correct functioning of the device may be compromised. Warning!
Because of the danger of electric shock, never remove the box of a device while it is in operation or connected to a power outlet. Avertissement!
En raison du risque d'lectrocution, ne retirez jamais la bote d'un appareil lorsqu'il est en fonctionnement ou branch une prise de courant. 5. If one of the following situations arises, get the equipment checked by service personnel:
The power cord or plug is damaged. Liquid has penetrated into the equipment. The equipment has been exposed to moisture. The equipment does not work well, or you cannot get it to work according to the user manual. The equipment has been dropped and damaged. The equipment has obvious signs of breakage. 6. Disconnect this equipment from any AC outlet before cleaning. Use a damp cloth. Do not use liquid or spray detergents for cleaning and keep this equipment away from humidity. Caution!
To avoid short-circuits and otherwise damaging the device, do not allow fluids to come in contact with the device. If fluids are accidentally spilled on the equipment, remove the affected unit from service as soon as possible and contact service personnel to verify that patient safety is not compromised. Attention!
Pour viter les courts-circuits et endommager l'appareil, ne laissez pas les liquides entrer en contact avec sont l'appareil. Si des accidentellement sur l'quipement, retirez l'unit concerne du service ds que possible et contactez le personnel de service pour vrifier que la scurit du patient n'est pas compromise. liquides rpandus 7. Put this equipment on a reliable surface during installation. Dropping it or letting it fall may cause damage. For plug-in equipment, the power outlet socket must be located near the equipment and must be easily accessible. Caution!
Do not leave this equipment in an uncontrolled environment where the Storage temperature is below 0 C or above 45 C. This may damage the equipment. Attention!
Ne laissez pas cet quipement dans un environnement non contrl o la temprature de stockage est infrieure 0 C ou suprieure 45 C. Ceci pourrait endommager l'quipement. 8. Grounding reliability can only be achieved when the equipment is connected to an equivalent receptacle marked Hospital Only or Hospital Grade. And, the equipment power cord shall be connected to a socket-
outlet with earthing connection. 9. Use a power cord that matches the voltage of the power outlet, which has been approved and complies with the safety standard of your particular country. 10. If the integrity of the protective earth conductor is in doubt. Please turn off the power switch. 11. To disconnect this product from the mains supply disconnects the mains plug from the socket outlet. The power supply is regarded as part of this equipment. 12. Make sure user not to contact SIP/SOPs and the 13. Do not switch on/off the power switch of the battery patient at the same time. system during operation. Warning!
Avertissement!
Warning!
Avertissement!
To avoid risk of electric shock, this equipment must only be connected to a supply mains with protective earth. Pour viter tout risque d'lectrocution, cet quipement doit uniquement tre raccord une alimentation secteur avec terre de protection. No modification of this equipment is allowed. Aucune modification de cet quipement n'est autorise. 14. The power cord for use on the device shall be no less robust than ordinary tough rubber sheathed flexible cord (IEC 60245-1:2003, Annex A, designation 53) or ordinary polyvinyl chloride sheathed flexible cord (IEC 60227-1:1993, Annex A, design. 53. For the US/CA the requirements of the NEC and Canadian code shall be followed (US and CA national differences). Warning!
Avertissement!
Battery system, equipotential pin, metal wiring on equipotential pin, wheels and brake shall be replaced/send back to maintain by the manufacturer every two years, risks of function failure, electrical shock, equipment damage, environment pollution and etc. may occur if not doing so. Le systme de batterie, la broche quipotentielle, le cblage mtallique sur la broche quipotentielle, les roues et le frein doivent tre remplacs /
renvoys par le fabricant tous les deux ans, les risques de dfaillance de fonctionnement, les chocs lectriques, les dommages matriels, etc. Ce faisant. 15. If your computer clock is unable to keep accurate time, please check the battery. Caution!
Attention!
Caution!
Attention!
When the battery has problem of charging. Please contact a qualified technician or your retailer. The computer is provided with a battery-
powered real-time clock circuit. There is a danger of explosion if battery is incorrectly replaced. Replace only with type recommended by the manufacturer. Discard used batteries according to the manufacturer's instructions. equivalent same or Lorsque la batterie a un problme de charge. Veuillez contacter un technicien qualifi ou votre revendeur. L'ordinateur est quip d'un circuit d'horloge en temps rel aliment par batterie. Il y a un risque d'explosion si la batterie est remplace. Remplacez uniquement par le mme type ou un type quivalent recommand par le fabricant. Jetez les piles usages conformment aux instructions du fabricant. incorrectement or the endorse When servicing the device, always use replacement parts that meet Advantech standards. Advantech Medical cannot warrant safe performance of third-party replacement parts for use with our medical device. Lors de la maintenance de l'appareil, utilisez toujours des pices de rechange conformes aux normes Advantech. Advantech Medical ne peut pas garantir ou performances scuritaires des pices de rechange endosser les tierces utiliser avec notre dispositif mdical. 16. Make sure the user does not allow contact between SIP/SOPs and the patient at the same time. 17. Follow national, state or local requirements to dispose of unit. 18. Maintenance: to properly maintain and clean the surfaces, use only the approved products or clean with a dry applicator. 19. Contact information:
No.1, Alley 20, Lane 26, Rueiguang Road Neihu District, Taipei, Taiwan 114, R.O.C. TEL: +886 2-7732-3399 20. This equipment shall not be used as a life support system. 21. Use a power cord that matches the voltage of the power outlet, which has been approved and complies with the safety standard of your particular country. 22. Do not place the power cord where it is difficult to disconnect and may be stepped by other person Environmental protection. Follow national requirements to dispose of unit. WARNING - Do not modify this equipment without authorization of the manufacturer. WARNING To avoid risk of electric shock, this equipment must only be connected to a supply mains with protective earth. CAUTION: This adapter Delta / ADP-65SD B is a forming part of the device. 23. 24. 25. 26. Remove the power cord to fully turn off the device when the battery pack is empty. 27. Classification:
1). Class I 2). No applied part 3). Continuous Operation 28. CAUTION! This product: AIM-68S is used with the Qualified & certificated power adapter: Delta /
ADP-65SD B. Output: 20 Vdc / 3.25 A max 29. DISCLAIMER: This set of instructions is given 30. according to IEC 704-1. Advantech disclaims all responsibility for the accuracy of any statements contained herein. In case of serious incident that has occurred, please contact the manufacturer and local authorities immediately. Notice: It is recommended to install the appropriate soft if have any question, please contact the manufacturer for further assistance. Notice: To prevent unauthorized access, it is recommended to install suitable anti-virus software or do not connect to unsafe external networks Complies with FDA performance standards for laser products except for deviations pursuant to Laser Notice No. 56, dated (Insert date of this guidance.) IEC 60825-1:2014 Caution - Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure Attention - L'utilisation des commandes ou rglages ou l'excution des procdures autres que celles spcifies dans les presents exigences peuvent tre la cause d'une exposition un rayonnement dangereux Explanation of Graphical Symbols IEC 60878 and ISO 3864-B.3.6 :
Warning dangerous voltage. ISO 7000-0434 : Caution, consult ACCOMPANYING DOCUMENTS. ISO 7000-1641 : Follow operating instructions or consult instructions for use. IEC 60417-5009 : STAND-BY. IEC 60417-5032 : Alternating Current. IEC 60417-5031 : Direct Current. Tablet Specifications 2. 3. 4. 5. Replacing the battery pack 1. Turn off the computer and disconnect the AC adapter. Carefully place the computer upside down. Remove the battery pack cover (P on the description of parts.) P Remove the battery pack out of the slot. Insert the new battery pack all the way into the slot Put the battery pack cover back 6. Cleaning and Disinfecting During normal use of the AIM tablet the device may become dirty and should be regularly cleaned. Turn off the AIM-68S and unplug the power Wipe the screen and exterior with a soft, damp Steps:
1. cord. 2. cloth moistened only with water. Do not use liquid or aerosol cleaners on the screen, as these will discolor the finish and damage the screen. 3. Clean the LCD display only with a soft cloth dampened with 60% above isopropyl alcohol or 60%
above ethyl alcohol each time after use. Attention!
Caution!
Do not immerse or rinse the AIM tablet or its peripherals. If you accidentally spill liquid on the device, disconnect the unit from the power source. Contact your IT support department regarding the continued safety of the unit before placing it back in operation-Do not spray cleaning agent on the chassis. Do not use disinfectants that contain phenol. Do not autoclave or clean the AIM Tablet or its peripherals with strong aromatic, chlorinated, ketone, ether, or ether solvents, sharp tools or abrasives. Never immerse electrical connectors in water or other liquids. Operating Principle The device provides input through touch panel, hard keys located at the bottom of it, accessories through USB ports or its LAN/WLAN connections. The device computes the input data with its processing unit and then output the generated data to LCD panel, accessories or other devices through its I/O ports or through its LAN/WLAN connections. The device is able to store data in its storage, and when the device is turned off, still maintain the data in the memory units of the storage. Connecting the Power Cord The AIM tablet can be powered by AC/DC power adapter. Be sure to always handle the power cords by holding the plug ends only. Follow these procedures in order:
1. Connect the DC plug of the power adapter to AIM tablet product DC in connector. (Step 1) 2. Connect the 2 pin male plug of the power cord to an electrical outlet. (Step 2) Disposing of Old Products Within the European Union EU-wide legislation, as implemented in each member state, requires that waste electrical and electronic products carrying the mark shown at left must be disposed of separately from normal household waste. This includes monitors and electrical accessories, such as signal cables or power cords. When you need to dis-pose of your display products, please follow the guidance of your local authority, or ask the shop where you purchased the product, or if applicable, follow any agreements made between you and the provider. The mark on electrical and electronic products only applies to the current European Union Member States. CPUAlder Lake-N N200/N50 (TDP: 6W)Memory/Storage8G LPDDR5 RAM/128G or 256G m.2 NVMe SSDOSWindows 10 LTSC, Windows 11Display10.1 19201200 LCD 380nits or 800 nits, 10-point multi-touch P-CAPMultimedia2 x internal speaker (2W), 2 x digital microphoneCameraFront: 5MP FF with USB, Rear: 13MP with AF/LED FlashlightSensorsAmbient light sensor, e-compass, g-sensor, gyroscopeBarcodeBuilt in Barcode EM50S-20 (Optional)Add On ModuleAIM extension 14-pin pogo connector: 1 x USB 2.0, 1 x 2-wire UART,5V/1A powerWLANIEEE 802.11a/b/g/n/ac/ax, Bluetooth 5.3NFC13.56 MHz, compatible with ISO 15693, ISO 14443A, ISO 14443B,FeliCaLED1x Power Indicator LED (Blue/Orange/Green),1x BCR Indicator LED (Blue/Orange/Green)Control button1x power button, 1x programmable button, 1x Volume button1x USB3.1 Type C for Charging &DP, 1x USB 3.1 type-A , 1 x comboaudio jack1 x AIM docking pogo connectorBatteryAbout 46.31 Wh for 5 hrs battery life with LCD 300 nits, WiFi on, run1080PRTC BatteryRechargeable RTC BatteryTPM 2.0Support TPM 2.0 chipsetReliabilityIP65, 1.2mDimension& Weight280 x 18.2 x 180.1 mm &1.1 KgOperating Temp.Operating: -10 ~50 C ; Storage: -20 ~60 CIOAIM-68S Declaration of Conformity CE Conformity Statement Radio products with the CE alert marking comply with the RED Directive (2014/53/EU) issued by the Commission of the European Community. Compliance with this directive implies conformity to the following European Norms (in brackets are the equivalent international standards). EN 62368-1 (IEC62368-1) - Product Safety ETSI EN 300 328 Technical requirement for radio equipment ETSI EN 301 893 Technical requirement for radio equipment ETSI EN 300 330 Short Range Devices (SRD) ETSI EN 300 440 Short Range Devices (SRD) ETSI EN 303 687 6 GHz WAS/RLAN ETSI EN 301 489 General EMC requirements for radio equipment Products that contain the radio transmitter are labeled with CE alert marking and may also carry the CE logo. The full text of the EU declaration of conformity is available at the following internet address:
https://www.advantech.com The device is restricted to indoor use only when operating in the 5150 to 5350 MHz frequency range. This device is intended for indoor use only when operating in the frequency range 5945 to 6425 MHz which is applicable in countries that support WiFi 6E. The adapter shall be installed near the equipment and shall be easily accessible. Caution - Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions. Slave station: The transmission of radio equipment is indoors use only CE RF Exposure warning This device meets the EU requirements (2014/53/EU) on the limitation of exposure of the general public to electromagnetic fields by way of health protection. The limits are part of extensive recommendations for the protection of the general public. These recommendations have been developed and checked by independent scientific organizations through regular and thorough evaluations of scientific studies. The unit of measurement for the European Councils recommended limit for mobile devices is the Specific Absorption Rate
(SAR), and the SAR limit is 2.0 W/Kg averaged over 10 grams of body tissue. It meets the requirements of the International Commission on Non-Ionizing Radiation Protection (ICNIRP). For next-to-body operation, this device has been tested and meets the ICNRP exposure guidelines and the European Standard EN 50566 and EN 62209-2. SAR is measured with the device directly contacted to the body while transmitting at the highest certified output power level in all frequency bands of the mobile device. FCC Compliance Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/ TV technician for help. To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. (Example: use only shielded interface cables when connecting to computer or peripheral devices). This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1) This device may not cause harmful interference, and This device must accept any interference received, including interference that may cause undesired operation. 2) 15.21 Any changes or modifications not expressly approved by the party responsible for compliance could void the authority to operate equipment. This device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. For product available in the USA/Canada market, only channel 1~11 can be operated. Selection of other channels is not possible. his device is slave equipment, the device is not radar detection and not ad-hoc operation in the DFS band. Operation of transmitters in the 5.925-7.125 GHz band is prohibited for control of or communications with unmanned aircraft systems. FCC Radiation Exposure Statement This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment for body-worn configuration in direct contact to the phantom. This device complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. End user must follow the specific operating instructions for satisfying RF exposure compliance. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. The portable device is designed to meet the requirements for exposure to radio waves established by the Federal Communications Commission (USA). These requirements set a SAR limit of 1.6 W/kg averaged over one gram of tissue. The highest SAR value reported under this standard during product certification for use when properly worn on the body The FCC has granted an Equipment Authorization for this device with all reported SAR levels evaluated as in compliance with the FCC RF exposure guidelines. SAR information on this device is on file with the FCC and can be found under the Display Grant section of https://apps.fcc.gov/oetcf/eas/reports/GenericSearch.cf m after searching on FCC ID: M82-AIM-68S. IC warning statement This device complies with Industry Canadas licence-
exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause interference;
and (2) This device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. This radio transmitter has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance are strictly prohibited for use with this device. Le present emetteur radio a ete approuve par Industrie Canada pour fonctionner avec les types d'antenne enumeres ci-dessous et ayant un gain admissible maximal et l'impedance requise pour chaque type d'antenne. Les types d'antenne non inclus dans cette liste, ou dont le gain est superieur au gain maximal indique, sont strictement interdits pour l'exploitation de l'emetteur.
(i)the device for operation in the band 51505250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile satellite systems; (For devices installed in vehicles point i. is not required.) Users should also be advised that high-power radars are allocated as primary users (i.e. priority users) of the bands 5250-5350 MHz and 5650-5850 MHz and that these radars could cause interference and/or damage to LE-LAN devices.
(i) l'appareil pour fonctionner dans la bande 5150-5250 MHz est rserv une utilisation en intrieur afin de rduire les risques d'interfrences nuisibles la co-canal systmes mobiles par satellite;
Devraient galement tre informs les utilisateurs que les radars haute puissance sont dsigns comme utilisateurs principaux (c.--utilisateurs prioritaires) des bandes 5250-5350 MHz et 5650-5850 MHz et que ces radars pourraient provoquer des interfrences et / ou endommager les appareils LE-LAN. Devices shall not be used for control of or communications with unmanned aircraft systems. Les appareils ne doivent pas tre utiliss pour contrler ou communiquer avec des systmes d'aronefs sans pilote. IC Radiation Exposure Statement This EUT is compliance with SAR for general population/uncontrolled exposure limits in IC RSS-102. This equipment should be installed and operated with minimum distance 0 cm between the radiator & your body. Cet EUT est la conformite avec SAR pour la population generale / les limites d'exposition incontrolees dans IC RSS-102. Cet equipement doit etre installe et utilise a une distance minimale de 0 cm entre le radiateur et votre corps. This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment. End user must follow the specific operating instructions for satisfying RF exposure compliance. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. The portable device is designed to meet the requirements for exposure to radio waves established by the ISED. These requirements set a SAR limit of 1.6 W/kg averaged over one gram of tissue. The highest SAR value reported under this standard during product certification for use when properly worn on the body. Cet quipement est conforme aux limites dexposition aux rayonnements ISED tablies pour un environnement non contrl. Lutilisateur final doit suivre les instructions spcifiques pour satisfaire les normes. Cet metteur ne doit pas tre co-implant ou fonctionner en conjonction avec toute autre antenne ou transmetteur. BSMI 30 10 2 2 1
: 26201
: 02-27927818 Additional Information and Assistance Contact your distributor, sales representative, or Advantech's customer service center for technical support if you need additional assistance. Please have the following information ready before you call:
Product name and serial number Description of your peripheral attachments Description of your software (operating system, version, application software, etc.) A complete description of the problem The exact wording of any error messages This equipment is a source of electromagnetic waves. Before use please, make sure that there are not EMI sensitive devices in its surrounding which may mal-
function therefore. Environmental protection Follow national requirements to dispose of unit. Manufacturer:
Advantech Co., Ltd. No.1, Alley 20, Lane 26, Rueiguang Road Neihu District, Taipei, Taiwan 114, R.O.C. TEL: (02) 7732-3399 Distributed in Europe by:
Advantech Europe GmbH Kolberger Stra e 7 D-40599 Dsseldorf, Germany Tel: 49-211-97477350 Fax: 49-211-97477300 Visit the Advantech websites at www.advantech.com or www.advantech.com.tw if you need more information. AIM-68S AIM-68S http://www.advantech.com/
http://support.advantech.com AIM-68S 2 024 1
: 26 20 1
: 02-27927818 A:
B: (/) C: Barcode D: () E:
F:
G:
H: Docking Pogo Connector (USB3.0) I: LED J: Barcode LED K: () L: USB 3.1 Type-A M: USB 3.1 Type C N: NFC O:
P:
Q:
1. Delta : ADP-65SD B AIM-68S 20 Vdc / 3.25 A Advantech 2. (A) 3 3. 1 5 4. :
: 0C+40C
-10C+50C
-20C+60C
1. 2.3010 3. 221 NCC AIM-68S AdvantechAIM-68S-BAT 11.55Vdc, 4010mAh, 46.31Wh
0C 40C
-20C 60C AIM-68S