all | frequencies |
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|
manual | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 2 3 4 |
|
User Manual | Users Manual | 4.78 MiB | June 29 2022 | |||
1 2 3 4 |
|
Internal Photos | Internal Photos | 5.21 MiB | June 29 2022 | |||
1 2 3 4 |
|
External Photos | External Photos | 1.15 MiB | June 29 2022 | |||
1 2 3 4 |
|
ID Label and Label Location | ID Label/Location Info | 221.22 KiB | June 29 2022 | |||
1 2 3 4 |
|
Attestation Letter | Attestation Statements | 73.46 KiB | June 29 2022 | |||
1 2 3 4 | Block Diagram | Block Diagram | June 29 2022 | confidential | ||||
1 2 3 4 |
|
FCC Long Term Confidential Authorization Form | Cover Letter(s) | 23.44 KiB | June 29 2022 | |||
1 2 3 4 | Operation Description | Operational Description | June 29 2022 | confidential | ||||
1 2 3 4 |
|
Power of Attorney Letter | Cover Letter(s) | 18.99 KiB | June 29 2022 | |||
1 2 3 4 |
|
RF Exposure | RF Exposure Info | 148.82 KiB | June 29 2022 | |||
1 2 3 4 | Schematics | Schematics | June 29 2022 | confidential | ||||
1 2 3 4 |
|
Test Report | Test Report | 1.30 MiB | June 29 2022 | |||
1 2 3 4 |
|
Test Setup Photos | Test Setup Photos | 718.23 KiB | June 29 2022 | |||
1 2 3 4 | Circuit Description | Operational Description | June 29 2022 | confidential |
1 2 3 4 | User Manual | Users Manual | 4.78 MiB | June 29 2022 |
Version: 1.0 | Date: Oct.2021 About This Manual Thank you for choosing Akuvox E18C door phone. This manual is intended for the administrators who need to properly configure the door phone. This manual applies to 18.30.2.23 version, and it provides all the configurations for the functions and features of E18C door phones. Please visit Akuvox forum or consult technical support for any new information or the latest firmwares. Introduction of Icons and Symbols Always abide by this information in order to prevent the persons Always abide by this information in order to prevent the damages to Informative information and advice from the efficient use of the Warning:
from injury. Caution:
the device. Note:
device. Tip:
Useful information for the quick and efficient use of the device. Related Documentation You are advised to refer to the related documents for more technical information via the link below:
https://knowledge.akuvox.com Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. if not FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment . This transmitter must not be colocated or operating in conjunction with any other antenna or transmitter. To maintain compliance with FCCs RF Exposure guidelines,this equipment should be installed and operated with minimum distance of 20cm from your body. Table of Contents 1. Product Overview.................................................................................................... 12. Change Log.............................................................................................................. 23. Model Specification............................................................................................... 34. Introduction to Configuration Menu.................................................................... 55. Access the Device................................................................................................... 7 5.1. Access the Device Setting on the device.................................................7 5.2. Access the Device Setting on the Web Interface....................................8 6. Time and Language Setting................................................................................10 6.1. Language Setting...................................................................................... 10 6.1.1. Language Setting on the Device..................................................10 6.1.2. Language Setting on the Device Web Interface........................11 6.2. Time Setting............................................................................................... 11 6.2.1. Configure Time Setting on the Device........................................ 11 6.2.2. Time Setting on the Device Web Interface.................................13 6.3. LED Setting.........................................................................................14 6.3.1. Configure Card Reader LED Setting............................................ 14 6.3.2. Configure LED White Light Setting..............................................15 6.4. LCD Screen Brightness Setting............................................................... 16 6.4.1. LCD Screen Brightness Setting on the Device.......................... 16 6.4.2. LCD Screen Brightness Setting on the Web Interface..............16 6.5. Screen Display configuration.................................................................. 17 6.5.1. Configure Screensaver.................................................................. 17 6.5.2. Configure Screensaver on the Device.................................17 6.5.3. Configure Screensaver on the Web Interface.................... 18 6.5.4. Customize Screensaver on the Web Interface.......................... 19 6.5.5. Home Screen Configuration......................................................... 20 6.6. Volume & Tone Configuration................................................................. 21 6.6.1. Volume Configuration................................................................... 21 6.6.1.1. Configure Volume on the Device...................................... 21 6.6.1.2. Configure Volume on the Web Interface......................... 22 6.6.2. Upload Open Door Tone................................................................ 23 6.6.3. Configure Door Open Prompt Text.............................................. 23 6.6.4. Configure Hang-up Tone.............................................................. 24 7. Network Setting.................................................................................................... 25 7.1. Device Network Connection Setting.......................................................25 7.2. Device Local RTP configuration..............................................................26 7.3. Device Deployment in Network...............................................................28 7.4. NAT Setting.................................................................................................29 8. Intercom Call Configuration............................................................................... 31 8.1. IP call & IP Call Configuration................................................................. 31 8.1.1. Make IP/SIP calls...........................................................................31 8.1.2. IP Call Configuration......................................................................32 8.2. SIP Call &SIP Call Configuration............................................................. 32 8.2.1. SIP Account Registration..............................................................33 8.2.1.1. Configure SIP Account on the Device..............................33 8.2.1.2. Configure SIP Account on the Web Interface.................34 8.2.2. SIP Server Configuration.............................................................. 35 8.2.3. Configure SIP Ports for SIP Calls................................................ 36 8.2.4. Configure Outbound Proxy Server...............................................36 8.2.5. Configure Data Transmission Type.............................................37 8.3. Dial Options Configuration...................................................................... 38 8.3.1. Quick Dial by Number Replacement........................................... 38 8.3.2. Quick Dial By Number Replacement on the Device..................38 8.3.2.1. Quick Dial by Number Replacement on the Device.......39 8.4. Call Auto-answer Configuration............................................................. 40 8.5. Call Settings............................................................................................... 41 8.5.1. Maximum Call Duration Setting...................................................41 8.5.2. Maximum Dial Duration Setting.................................................. 42 8.5.3. Audio& Video Codec Configuration for SIP Calls......................43 8.5.3.1. Configure Audio Codec...................................................... 43 8.5.3.2. Configure Video Codec...................................................... 44 8.6. Configure DTMF Data Transmission......................................................45 9. Phone Book Configuration..................................................................................47 9.1. Phone Book Configuration on the Device..............................................47 9.2. Phone Book Configuration on the Web Interface.................................48 9.2.1. Manage Contact Groups on the Web Interface......................... 48 9.2.2. Contact List Configuration on the Web Interface..................... 48 9.2.2.1. Contact List Display Setting............................................. 48 10. Relay Switch Setting.......................................................................................... 50 10.1. Relay Switch Setting...............................................................................50 10.2. DTMF Code Configuration..................................................................... 51 10.3. Web Relay Setting................................................................................... 52 10.3.1. Configure Web Relay on the Web Interface............................. 52 10.3.2. Configure Web Relay on the Device.......................................... 54 10.4. Relay Schedule........................................................................................ 54 11. Door Access Schedule Management.............................................................. 56 11.1. Configure Door Access Schedule......................................................... 56 11.1.1. Create Door Access Schedule on the Web Interface............. 56 11.1.2. Create Door Access Schedule on the Device.......................... 58 11.1.3. Import and Export Door Access Schedule...............................59 11.1.4. Edit the Door Access Schedule..................................................60 11.1.4.1. Edit the Door Access Schedule on the Web Interface 60 11.1.4.2. Edit the Door Access Schedule on the Device............. 60 12. Door Unlock Configuration............................................................................... 62 12.1. Configure PIN Code for Door Unlock................................................... 62 12.1.1. Configure Public PIN code......................................................... 62 12.1.2. Configure Private PIN Code on the Device.............................. 63 12.1.3. Configure Private PIN Code on the Web Interface..................64 12.1.4. Configure Private PIN Access Mode.........................................66 12.2. Configure RF Card for Door Unlock...................................................... 66 12.2.1. Configure RF Card on the Web Interface..................................66 12.2.1.1. Configure RF Card Code Format............................................ 67 12.2.2. Configure Facial Recognition for Door Unlock........................68 12.2.2.1. Configure Facial Recognition on the Device................ 68 12.2.2.2. Configure Facial Recognition on Web Interface.......... 69 12.3. Configure Door Access Using Configured Files................................. 69 12.4. Edit the User(s)-specific door access data........................................ 70 12.4.1. Unlock by QR Code.............................................................................. 71 12.4.2. Unlock by Bluetooth............................................................................ 71 12.4.3. Unlock by NFC.............................................................................. 72 12.4.4. Unlock by HTTP Command on Web Browser..................................72 12.4.5. Unlock by Exit Button by the Door.................................................... 73 12.4.6. Unlock by Reception Tab....................................................................74 12.4.7. Body Temperature Measurement for Door Access........................75 12.4.7.1. Body Temperature Measurement Configuration.................75 13. Security................................................................................................................78 13.1. Tamper Alarm Setting.............................................................................78 13.2. Voice Encryption..................................................................................... 79 13.3. Motion Detection.....................................................................................79 13.3.1. Configure Motion Detection on the Web Interface................. 79 13.3.2. Configure Motion Detection on the Device..............................81 13.4. Security Notification Setting................................................................. 81 13.4.1. Email Notification Setting...........................................................81 13.4.2. FTP Notification setting..............................................................83 13.4.3. TFTP Notification Setting........................................................... 83 13.4.4. SIP Call Notification.................................................................... 84 13.5. Web Interface Automatic Log-out........................................................84 14. Monitor and Image.............................................................................................86 14.1. Mjpeg Image Capturing..........................................................................86 14.2. Live Stream.............................................................................................. 87 14.3. RTSP Stream Monitoring....................................................................... 89 14.3.1. RTSP Basic Setting......................................................................89 14.3.2. RTSP Stream Setting...................................................................90 14.4. ONVIF........................................................................................................ 92 15. Logs......................................................................................................................94 15.1. Call Logs................................................................................................... 94 15.2. Door Logs................................................................................................. 94 15.3. Temperature Log..................................................................................... 96 15.4. Export Logs.............................................................................................. 96 16. Debug................................................................................................................... 98 16.1. System Log for Debugging....................................................................98 16.2. PCAP for Debugging............................................................................... 99 16.3. User Agent................................................................................................99 17. Firmware Upgrade........................................................................................... 101 18. Backup...............................................................................................................103 19. Auto-provisioning............................................................................................ 105 19.1. Configuration Files for Auto-provisioning........................................ 105 19.2. AutoP Schedule.....................................................................................106 19.3. PNP Configuration................................................................................ 106 19.4. DHCP Provisioning Configuration...................................................... 107 19.5. Static Provisioning Configuration...................................................... 108 20. Integration with Third Party Device.............................................................. 111 20.1. Integration via Wiegand....................................................................... 111 20.2. Integration via RS485...........................................................................112 20.3. OSDP Setting......................................................................................... 113 20.4. Integration via HTTP API..................................................................... 113 20.5. Power Output Control...........................................................................116 21. Password Modification................................................................................... 117 22. System Reboot&Reset.................................................................................... 118 22.1. Reboot.................................................................................................... 118 22.2. Reset....................................................................................................... 119 23. Abbreviations....................................................................................................121 24. FAQ.....................................................................................................................123 25. Contact Us........................................................................................................ 126 1.Product Overview E18C Door Phone Administrator Guide Akuvox E18C is an Liunx-based with a touch screen. It incorporates audio Its and video communications, access control, and video surveillance. finely-tuned SmartPlus and AI-based communication technology allow featured customization to better suit your operation habit. E18C multiple ports, such as RS485 and Wiegand ports, can be used to easily integrate external digital systems, such as elevator controller and fire alarm detector, helping to create a holistic control of building entrance and its surroundings and giving you a great sense of security via a variety of access such as card access, NFC, Bluetooth, QR code and newly added door access in an accompaniment with body temperature measurement. E18C door phone applies to residential buildings, office buildings,and their complex. AKUVOX SMART INTERCOM www.akuvox.com 1 E18C Door Phone Administrator Guide 2.Change Log The change log will be updated here along with the changes in new software version. AKUVOX SMART INTERCOM www.akuvox.com 2 3.Model Specification E18C Door Phone Administrator Guide Model
Feature Display Touch Screen Button Housing Material Relay Out Relay In RS485 PoE Resolution Brightness RAM ROM Card Reader Wi-Fi Bluetooth IP Rating Temperature Detection Face recognition LTE USB External SD Card E18C 7 IPS X Plastic 2 3 1024x600 500cd/m2 1GB 8GB 13.56MHz X IP65 Optional X X X AKUVOX SMART INTERCOM www.akuvox.com 3 E18C Door Phone Administrator Guide Wall Mounting Flush Mounting Desk Mounting POE Stand by Power POE Full Load Consumption Power Adapter Standby Power Power Adapter Full Load Consumption Color Option X 6.0W 11W 5.8W 10.35W Black AKUVOX SMART INTERCOM www.akuvox.com 4 4.Introduction to Configuration Menu E18C Door Phone Administrator Guide Status: this sections gives you basic information such as product information, Network Information, and account information etc. Account: this section concerns SIP account, SIP server, proxy server, transport protocol type, outbound proximity server. Network: this section mainly deals with DHCP&Static IP setting, and device deployment etc. Intercom: this section covers Intercom call setting, call log etc. Surveillance: this section includes audio&video related settings such as Live stream, RTSP, ONVIF, MJPEG. Access Control: this section includes input type setting, relay setting, door access control in terms private PIN code, Facial recognition, RF card, and BLE setting as well log related configurations such as door log and temperature log. Device: this section concerns LED light setting, ODSP Setting, screen saver setting, sound&volume setting and third-party integration in terms of integration via Wiegand, RS485. Setting:
this second deals with time &language setting, security notification settings and door prompt text setting. Upgrade: this section covers Firmware upgrade, device reset&reboot, configuration file auto-provisioning, PCAP. Security: this section is for Password modification, tamper alarm, and web interface automatic-logout. AKUVOX SMART INTERCOM www.akuvox.com 5 Mode selection :
E18C Door Phone Administrator Guide 1. Discovery mode:
It is a plug and play configuration mode. Akuvox devices will configure themselves automatically when users power on the devices and connect them to network. It is super time-saving mode and it will greatly bring users convenience by reducing manual operations. This mode requires no prior configurations previously by the administrator. 2. SmartPlus mode: Akuvox SmartPlus is an all-in-one management system. Akuvox SmartPlus is the mobile service that allows audio, video, remote access control between smart phones and Akuvox intercoms. All configurations in the device will be issued automatically from cloud. If users decide to use Akuvox Smartplus please contact Akuvox technical support, and they will help you configure the related settings before using. 3. SDMC mode: SDMC (SIP Device Management Controller) is a simple and comprehensive software for building management. It provides a topography for a community while offering you a graphical configuration interface for the door access, intercom, monitoring, alarm etc.,. It is a convenient tool for property manager to manage , operate and maintain the community. Tool selection Akuvox has many configuration tools for you to set up devices more conveniently. Here we list some common tools, please contact your administrator to get the tool if you need them. 1. SDMC: SDMC is suitable for the management of Akuvox devices large information, remote including access control, resident 2. Akuvox Upgrade tool: Upgrade Akuvox devices in batch on a LAN (Local communities, device control etc.,. Area Network). 3. Akuvox PC Manager: Distribute all configuration items in batch on a LAN. 4. IP scanner: it is used to search Akuvox device IP addresses on a LAN. 5. FacePro: Manage face data in batch for the door phone on a LAN. AKUVOX SMART INTERCOM www.akuvox.com 6 5.Access the Device E18C Door Phone Administrator Guide E18C door phoneinal system setting can be either accessed on the device directly or on the device web interface. 5.1. Access the Device Setting on the device If you want to access the device setting to configure and adjust the parameters, you can do it directly on the device. You can Long press any where on the initial screen for approximately five seconds, Enter the default PIN code admin, then press Confirm tab. AKUVOX SMART INTERCOM www.akuvox.com 7 5.2. Access the Device Setting on the Web E18C Door Phone Administrator Guide Interface You can also enter the device IP address on the web browser, an enter the username and password to log in the device web interface where you can configure and adjust parameter etc. Tip:
You can also obtain the device IP address using the Akuvox IP scanner to log in the device web interface. Please refer to the URL below for the IP scanner application:
https://knowledge.akuvox.com/docs/how-to-obtain-ip-address-via
-ip-scanner?highlight=ip%20scanner AKUVOX SMART INTERCOM www.akuvox.com 8 E18C Door Phone Administrator Guide Note:
Google Chrome browser is strongly recommended. The Initial user name and password are admin and please be case-sensitive to the user names and passwords entered. AKUVOX SMART INTERCOM www.akuvox.com 9 6.Time and Language Setting E18C Door Phone Administrator Guide 6.1. Language Setting When you first set up the device, you might need to set the language to your needs, or you can do it later if needed. And the language can either be set up directly on the device or on the device web interface according to your preference. 6.1.1. Language Setting on the Device Device Language can be configured on the device and on the device web interface that allows you to select or change the language for screen display to your preference. Path : Display&Sounds > Language. AKUVOX SMART INTERCOM www.akuvox.com 10 6.1.2. Language Setting on the Device Web Interface. E18C Door Phone Administrator Guide To configure the language on the web interface. Path:Setting >Time/Lang >
LCD Language. Parameter Set-up:
Type: choose a suitable web language. Normally, English is the default web and LCD language. 6.2. Time Setting Time setting can be set up on the device and on the device web interface in terms of time zone, date and time format etc. 6.2.1.Configure Time Setting on the Device Time setting on the web interface allows you to set up time and date manually while allowing you to use NTP server address that you obtained to automatically synchronize your time and date. And when your time zone is selected, the device will automatically notify the NTP server of its time zone selected so that the NTP server can synchronize the selected time zone setting to your device. Path:Display&Sounds > Language. AKUVOX SMART INTERCOM www.akuvox.com 11 E18C Door Phone Administrator Guide Parameter Set-up:
Automatic Date&Time: Automatic Date&Time is toggled on by default, which allows the date& time to be automatically set up and synchronized with the default time zone and the NTP server (Network Time Protocol). You can also set it up manually by toggling off the switch first then enter the time and date you want before pressing the Save tab for the validation. Date: click on Date to set the date. Time: click on Time to set the time. Time Zone: select the specific time zone depending on where the device is used and then press Confirm tab for the confirmation. The default time zone is GMT GMT+0.00. Date Format: select the date format as you like among three format options: M-D-Y; D-M-Y; Y-M-D and then press the Confirm tab for the confirmation. Time Format: you can either select 12 hour or 24-hour time format as you like, and then press the Confirm tab for the confirmation. AKUVOX SMART INTERCOM www.akuvox.com 12 E18C Door Phone Administrator Guide Note:
When the Automatic Date&Time toggle switch is toggled off then parameters related to NTP server will become not editable. And when the switch is toggled on, then time and date will be denied editing. 6.2.2.Time Setting on the Device Web Interface You can configure time setting on the web interface. Path :Setting >
Time/Lang > Time. Parameter Set-up:
Automatic Date&Time Enabled: tick the checkbox to allow the date& time in the device to be automatically set up and synchronized with the default time zone and the NTP server (Network Time Protocol). if it untick the checkbox, then you are allows to set up the time manually on the web interface. Time Zone: select the specific time zone depending on where the device is used and then press Confirm tab for the confirmation. The default time zone is GMT+0.00. Preferred Server: enter the NTP server you obtained in the NTP Server field. AKUVOX SMART INTERCOM www.akuvox.com 13 E18C Door Phone Administrator Guide Note:
When the check box is unticked , the parameters related to NTP server will become uneditable. 6.3. LED Setting 6.3.1. Configure Card Reader LED Setting You can enable or disable the LED lighting on the card reader area as needed on the web interface. Meanwhile, If you do not want to have the LED light on the card reader area to stay on, you can also set the timing for the exact time span during which the LED light can be disabled in order to reduce the electrical power consumption. Path: Device > Light > LED of Swiping Card Area. Parameter set-up:
and vice versa. Enabled: Tick the check box if want to enable the card reader LED lighting Start Time - End Time (H): enter the time span for the LED lighting to be valid, e.g. if the time span is from 18-22 it means LED light will stay on during the time span from 6:00 pm to 10:00 pm during one day (24 hours). AKUVOX SMART INTERCOM www.akuvox.com 14 6.3.2. Configure LED White Light Setting E18C Door Phone Administrator Guide LED White light is used to reinforce the lighting for facial recognition as well as for the QR code access as needed in the dark environment. You can set the white light function properly on the device web interface. Path: Device >
Light > White Light. Parameter Set-up:
Mode: select Auto or OFF. If you select Auto then the white light will turn on for 5 minutes for facial recognition and QR code scan. And if you select Off then the white light will be turned off. Max White Light Value: set the white light value from 1-5, and the default white light value is 3. The greater value it is, the brighter the light will be. Note:
IR LED light should be triggered first before the white light can be valid in the facial recognition, however IR LED light does not need to be triggered for the white light function in the QR code scan. AKUVOX SMART INTERCOM www.akuvox.com 15 6.4. LCD Screen Brightness Setting E18C Door Phone Administrator Guide If you want adjust the screen brightness in order to see the screen at greater ease in an environment with higher light intensity, you need to set up the related parameters. 6.4.1.LCD Screen Brightness Setting on the Device You can adjust the screen brightness on the device. Path: Display&Sounds >
Backlight. 6.4.2.LCD Screen Brightness Setting on the Web Interface You can adjust the screen brightness on the web interface, you can go to Device > Light > Screen Backlight Brightness. Backlight Brightness (day): set the screen backlight brightness during the daytime with the value ranging from (0-255). AKUVOX SMART INTERCOM www.akuvox.com 16 6.5. Screen Display configuration E18C Door Phone Administrator Guide E18C door phones allow you to enjoy a variety of screen displays to enrich your visual and operational experience through the customized setting to your preference. 6.5.1.Configure Screensaver Screensaver configuration is for the screen protection when the device goes into idle status. You can make the device to go into idle status for a predefined time span when there is no operation on the device or no one is detected approaching. You can configure the screensaver on device and the device web interface. 6.5.2. Configure Screensaver on the Device You can configure Display&Sounds > Screensaver > Lock Screen. the screensaver on the device directly.Path:
AKUVOX SMART INTERCOM www.akuvox.com 17 Parameter Set-up:
E18C Door Phone Administrator Guide Screensaver Mode: move the toggle switch to the right to enable the screen saver function. Screensaver Timeset the screensaver duration after the device goes in to sleep mode. The default setting is 30 min. Sleep: set the screen saver start time range from 10 min. to 30 min, for example, if you set it as 10 m then the device will go into screen saver mode in 10 min. when when there is no operation on the device or no one is detected approaching 6.5.3. Configure Screensaver on the Web Interface To configure screensaver on the web interface, you can go to Device > LCD >
Standby Interface Display. Parameter Set-up:
Screensaver Mode: move the toggle switch to the right to enable the screen saver function. Screensaver Timeset the screensaver duration after the device goes in to sleep mode. Screensaver duration ranges from 5 seconds to 2 hours on the web interface. While the default setting is 30min. Sleep: set the screen saver start time range from 10 min. to 30 min, for example, if you set it as 10 m then the device will go into screen saver mode in 10 min. when when there is no operation on the device or no one is detected approaching. AKUVOX SMART INTERCOM www.akuvox.com 18 6.5.4.Customize Screensaver on the Web Interface E18C Door Phone Administrator Guide You can upload and customize screensaver pictures separately or in batch to the device and to the device web interface for publicity purpose or for a greater visual experience.You are allowed to upload a maximum of 5 pictures, and each picture will be displayed in rotation according to the ID order with specific time duration (Time Interval ) you set. You can go to Device > LCD >
Upload Screensaver. Parameter Setup:
Interval(Sec): Set the display time of each individual picture you uploaded in Interval (Sec.) the display time range is from 1-120 seconds.The default setting is 5 seconds. Note:
maximum. The pictures uploaded should be in JPG format with 2M pixel AKUVOX SMART INTERCOM www.akuvox.com 19 E18C Door Phone Administrator Guide 6.5.5.Home Screen Configuration You can change the home screen display through the configuration of tab name and tab arrangement on the device web interface if needed. Path:
Device > LCD > Key In Homepage Of The Building Theme. Parameter Set-up:
Type: select the tab type corresponding to the index number which indicates the tab position. For example, if you want to make Speed Dial tab to be displayed in position one, you can change the type in index number 1 to Speed Dial. And you can change another tab position accordingly. Name: enter a new name to replace the original type of name, but it does not change the attribute of the type. Value: enter the IP or SIP number to be attached to the reception icon for the speed dial. The number enter will be dialed out as you press the reception icon on the home screen. This field is only valid for speed dial. 20 6.6. Volume & Tone Configuration E18C Door Phone Administrator Guide Volume and tone configuration in E18C door phone refers to the Call volume(speaker), Mic volume, prompt volume (eg. open door tone) Moreover, you can upload the tone you like to enrich your personalized user experience. 6.6.1.Volume Configuration You can configure the Mic volume, speaker volume and temper alarm volume according to your need for the intercom-based audio&video communication. More over, you can also set up the tamper alarm volume when unwanted removal of the door phone occurs. 6.6.1.1. Configure Volume on the Device You can adjust the microphone volume, speaker volume, prompt volume on the device. Path: Display&Sounds > Volume. 21 Mic Volume: adjust the microphone volume according to your need. E18C Door Phone Administrator Guide Speaker volume: adjust the loudspeaker volume according to your need. Prompt Volume: adjust the prompt volume, which includes various types of prompt sound for door open success and failure, ringback, and temperature measurement sound etc. 6.6.1.2. Configure Volume on the Web Interface On the web interface, you can set the temper alarm volume, Mic volume, speaker volume, prompt volume. Path: Device > Audio > Volume Control. Parameter Setup:
Mic Volume: set the mic volume from 0-15 according to your need. The default Mic volume is 8. Speaker Volume: set the speaker volume from 0-15 according to your need. The default speaker volume is 8.. Tamper Alarm Volume: set the tamper alarm volume from 0-15 according to your need. The default volume is 8. Prompt Volume: adjust the prompt volume, which includes various types of prompt sound for door open success and failure, ringback, and temperature measurement sound etc. Tamper Alarm Volume: set the tamper alarm volume from 0-15 according 22 to your need. The default volume is 8. E18C Door Phone Administrator Guide 6.6.2.Upload Open Door Tone You can upload the Open Door Tone on the device web interface. Path:
Device >Audio > Open Door Tone Setting. 6.6.3. Configure Door Open Prompt Text You can enable or disable the door open prompt to be shown on the devices screen for door open failure and success. Path: Setting > Door > Door Setting General. Parameter Setup:
Open Door Succeeded Text Prompt : Tick the check box if you want to see the text prompt after the door open success and vice versa. 23 Open Door Failed Text Prompt : Tick the check box if you want to see the prompt words after the door open failure and vice versa. E18C Door Phone Administrator Guide 6.6.4.Configure Hang-up Tone You can customize your call hang-up tone if needed. Path: Device > Audio >
Hang Up Tone Setting. Han Up Tone Enabled: tick the checkbox to enable the function. Hang Up Tone Upload: upload the hang-up tone file in .wav format. And the file size shall be less than 200KB. You can click on Reset if you want to delete the uploaded file and the change it back to the default hang-up tone. 24 7. Network Setting E18C Door Phone Administrator Guide 7.1. Device Network Connection Setting You can configure the default DHCP mode (Dynamic Host Configuration Protocol) and static IP connection. More over, you can set up IP address, Subnet Mask, Default Gateway, and DNS servers. Parameter Set-up:
DHCP: select the DHCP mode by moving the toggle switch to the right. DHCP mode is the default network connection. If the DHCP mode is turned on, then the door phone will be assigned by the DHCP server with IP address, subnet mask, default gateway, and DNS server address automatically. Static IP: select the static IP mode by checking off the DHCP check box. When static IP mode is selected, then the IP address, subnet mask, default gateway, and DNS servers address have to be manually configured according to your actual network environment. IP Address: set up the IP Address if the static IP mode is selected. Subnet Mask: set up the subnet Mask according to your actual network 25 environment. E18C Door Phone Administrator Guide Default Gateway: set up the correct gateway default gateway according to the IP address of the default gateway. Preferred&Alternate DNS Server: set up preferred or alternate DNS Server
(Domain Name Server) according to your actual network environment. Preferred DNS server is the primary DNS server address while the alternate DNS server is the secondary server address, and the door phone will connect to the alternate server when the primary DNS server is unavailable. You can also configure the network work setting on the web interface. Path:
Network > Basic > LAN Port . 7.2. Device Local RTP configuration For the device network data transmission purpose, device needs to be set up with a range of RTP port (Real-time Transport Protocol) for establishing an 26 E18C Door Phone Administrator Guide exclusive range of data transmission in the network. Path:Network >
Advanced > Local RTP interface. Parameter set-up:
Starting RTP Port: enter the Port value in order to establish the start point for the exclusive data transmission range. Max RTP port: enter the Port value in order to establish the end point for the exclusive data transmission range. 7.3. Device Deployment in Network E18C should be deployed before they can be properly configured in the network environment in terms of their location, operation mode, address and extension numbers for the device control and the convenience of the management. Path:Network > Advanced > Connect Setting. Parameter Set-up:
28 E18C Door Phone Administrator Guide Server Mode: it is automatically set up according to the actual device connection with a specific server in the network such as SDMC or Cloud and None. None is the default factory setting indicating the device is not in any server type, therefore you are allowed to choose Cloud, SMDC in discovery mode. Discovery Mode: click Enabled to turn on the discovery mode of the device so that it can be discovered by other devices in the network,and click Disabled if you want to conceal the device so as not to be discovered by other devices. Device Node: specify the device address by entering device location information from the left to the right :Community, Unit, Stair, Floor, Room in sequence. Device extension: enter the device extension number for the device you installed Location: enter the location in which the device is installed and used. 7.4. NAT Setting NAT (Network Address Translation) allows hosts in an organizations private intranet to transparently connect to hosts in the public domain. There is no need for internal hosts to have registered Internet addresses. It is a way to translate the internal private network IP address into a legal network IP address technology. The NAT in the device web is limited to maintaining a connection with the remote SIP server. The principle is to send a heartbeat message to the remote SIP server at a set interval after the function is turned on. Otherwise, the server may judge that the device is offline and allocate the SIP assigned to other devices, resulting in failure to connect to it in the future. Path: Account > Advanced > NAT. 29 E18C Door Phone Administrator Guide Parameter Set-up:
UDP Keep Alive Messages:
If enabled, the device will send out the massage to the SIP sever so that SIP sever will recognize that the device is in on-line status. UDP Alive Msg Interval: set the message sending time interval from 5-60 seconds, the default is 30 seconds. RPort: enable the Rport when the SIP server is in WAN (Wide Area Network). 30 8.Intercom Call Configuration E18C Door Phone Administrator Guide Intercom call in the device can be configured to allow you to perform a variety of customized intercom calls such as IP call and SIP call for different application scenarios. 8.1. IP call & IP Call Configuration IP call can be made directly on the intercom device by entering the IP number on the device. And you can also disable the direct IP call if you allow no IP call to be made on the device. 8.1.1.Make IP/SIP calls You can press the dial tab and make IP or SIP calls. 31 E18C Door Phone Administrator Guide 8.1.2.IP Call Configuration You are required to set up a specific port the for the data transmission for the IP calls. Path: Intercom > Basic > Direct IP. Parameter set-up:
Enabled : tick the checkbox to enable or disable the direct IP call . For example if you do not allow direct IP call to be made on the device, you can disable the function. Direct IP Port: the direct IP Port is 5060 by default with the port range from 1-65535. And you enter any values within the range other than the 5060, you are required to check if the value entered is consistent with the corresponding value on the device you wish to establish a data transmission with. 8.2. SIP Call &SIP Call Configuration SIP calls (Session Initiation Protocol ) are established and supported by SIP servers. If the two intercom devices want to initiate SIP calls with each other, then they should be registered in the same SIP server. And SIP call parameters related to its account, server, and transport type need to configured first before you can make calls on the device. You can make SIP call ( Session Initiation Protocol ) in the same way as you do for making the IP calls on the device. However, SIP call parameters related to its account, server, and transport type need to configured first before you can make calls on the device. 32 E18C Door Phone Administrator Guide Note:
Akuvox currently has its own PBX called My PBX server, and it has also achieved compatibility with third-party PBX, you can refer to the
URL https://www.akuvox.com/PartnersTechnology.aspx?ptype=16 below:
8.2.1.SIP Account Registration E18C supports two SIP accounts that can all be registered according to your applications. You can for example, switch between them if any one of the accounts failed and become invalid. The SIP account can be configured on the device and on the device interface. 8.2.1.1. Configure SIP Account on the Device To configure SIP account on the device. Path: Account. Parameter Set-up:
Display Name: configure the name, for example the devices name to be shown on the device being called to. Register Name: enter the SIP account register Name obtained from the SIP account administrator. 33 User Name: enter the user name obtained from SIP account E18C Door Phone Administrator Guide administrator. Password: enter administrator. the password obtained from the SIP account Server IP: enter the SIP server address for the SIP account selected. Server port: enter the SIP server port for communication. The SIP port is 5060 by default. 8.2.1.2. Configure SIP Account on the Web Interface To configure the configuration on the web interface, you go to Basic > SIP Account interface. Account >
Parameter Set-up:
Status: check to see if the SIP account is registered or not. Account: select the exact account (Account 1&2) to be configured . 34 E18C Door Phone Administrator Guide Account Enabled: tick the checkbox to enable or disable registered SIP account. Display Name: configure the name, for example the devices name to be in 63 bytes of be shown on the device being called to. You can fill characters in length maximum Display Label: configure the device label to be shown on the device screen.You can fill in 63 bytes of characters in length maximum Register Name: enter the SIP account register Name obtained from the SIP account administrator. You can fill in 63 bytes of characters in length maximum. User Name: enter the user name obtained from SIP account administrator. You can fill in 63 bytes of characters in length maximum Password: enter the password obtained from the SIP account administrator.You can fill in 63 bytes of characters in length maximum. 8.2.2.SIP Server Configuration You are required to enter the SIP port registration and for SIP calls.Path: Account > Basic > Preferred SIP Server the devices SIP account for 35 E18C Door Phone Administrator Guide Parameter Set-up:
Server Address ( preferred SIP server) : enter the primary server IP address number or its URL. Server Address ( alternate SIP server): enter the backup SIP server IP address or its URL. SIP Server Port: set up SIP server port for data transmission. Registration Period: set up SIP account registration time pan. SIP re-registration will start automatically if the account registration fails during the registration time span. The default registration period is 1800, ranging from 30-65535s. 8.2.3.Configure SIP Ports for SIP Calls You are required to set up a SIP port range for making SIP calls. Parameter Setup:
Max Local SIP Port: enter the maximum SIP port ranging from 1024 to 65535. The default port setting is 5062. Min Local SIP Port: enter the minimum SIP port ranging from 1024 to 65535. The default port setting is 5062. 8.2.4. Configure Outbound Proxy Server An outbound proxy server is used to receive all initiating request messages and route them to the designated SIP server in order to establish call session 36 E18C Door Phone Administrator Guide via port-based data transmission. Path: Account > Basic > Outbound Proxy Server. Parameter Set-up:
proxy server. proxy server proxy server. Outbound Enabled : tick the checkbox to enable or disablethe outbound Preferred Server IP: enter the SIP address of the outbound proxy server. Port: enter the Port number for establish call session via the outbound Alternate Server IP: set up Backup Server IP for the back up outbound Port: enter the Port number for establish call session via the backup outbound proxy server. 8.2.5. Configure Data Transmission Type Datagram Protocol),TCP(Transmission SIP message can be transmitted in three data transmission protocols: UDP
(User Protocol),TLS
(Transport Layer Security) and DNS-SRV. In the meantime, you can also identify the server from which the data come from. Path: Account > Basic >
Transport Type. Control 37 E18C Door Phone Administrator Guide Parameter Set-up:
UDP: select UDP for unreliable but very efficient transport layer protocol. UDP is the default transport protocol. TCP: select TCP for Reliable but less-efficient transport layer protocol. TLS: select TLS for Secured and Reliable transport layer protocol. DNS-SRV: select DNS-SRV to obtain DNS record for specifying the location of services. And SRV not only records the server address but also the server port. Moreover, SRV can also be used to configure the priority and the weight of the server address. 8.3. Dial Options Configuration E18C offers a variety of Dial options that allows you to have fast dial experience while relieving you off memory burden due to long and complex dial numbers. 8.3.1.Quick Dial by Number Replacement If you want to replace the long and complex dial number with a shorter number that can be memorized at greater ease and convenience for making calls, you can configure the dial number replacement on the device and on the device web interface. You can replace a multiple device dial numbers such as IP address or SIP numbers with only one short number. 8.3.2.Quick Dial By Number Replacement on the Device 38 E18C Door Phone Administrator Guide You can replace the long SIP/IP number with the short number on the device. Path: Replace Rule > Add Replace Rule. Parameter Set-up:
Account: select the account to which you want to apply dial number replacement. The account is Auto by default ( to dial out from the account in which the dial number has been registered). You can select either account 1 or account 2 from which the number can be dial out. if you have registered the dial number in both Account 1 and Account 2 , then the number will be called out from Account 1 by default. Prefix: enter the short number to replace the dial number you wish to replace. Replace 1/2/3/4/5: enter the dial number(s) you wish to replace. It supports up to 5 number maximum for the replacement on the device configuration. For example if you replace five original dial numbers with a common short number such as 101 then the five intercom devices with the dial number will be called to at the same time when you dial 101. 8.3.2.1. Quick Dial by Number Replacement on the Device You can replace the long SIP/IP number with the short number on the web interface. Path: Intercom > Dial Plan. 39 E18C Door Phone Administrator Guide 8.4. Call Auto-answer Configuration Auto-answer is a function that allows you to answer the incoming call without picking up the phone. When auto-answer is enabled, the incoming call will be answered automatically based on the answering timing you defined. Configure auto-answer function Path: Intercom > Call Feature > Auto Answer. Enable Auto-answer mode Path: Account > Advanced > Call. 40 Parameter Set-up:
E18C Door Phone Administrator Guide Auto Answer: tick the checkbox to enable the auto-answer function. Auto Answer Delay: set up the delay time (from 0-5 sec.) before the call an be answered automatically. For example, if you set the delay time as 1 second, then the call will be answered in 1 second automatically. Auto Answer Mode: set up the Video or Audio mode you preferred for the automatic call answering. 8.5. Call Settings 8.5.1.Maximum Call Duration Setting E18C door phone allows you to set up the call time duration in receiving the call from the calling device as the caller side might forget to hang up the phone. When the call time duration is reached, the door phone will terminate the call automatically. Path: Intercom > Call Feature > Max Call Time Parameter Set-up:
Max Call Time: enter the call time duration according to your need
(Ranging from 2-30 min.). The default call time duration is 5 min. 41 E18C Door Phone Administrator Guide Note:
Max call time of device is also related with max call time of SIP server. If using SIP account to make a call, please pay attention to the max call time of SIP server. If the max call time of SIP server is shorter than the max call time of device , the shorter one is available. 8.5.2.Maximum Dial Duration Setting Maximum Dial duration is consisted of Maximum dial-in time duration and the maximum dial-out time. Maximum dial in time refers to the maximum time duration before the door phone hang up the call is not answered by the door phone. In contrary, Maximum dial-out time refers to the maximum time duration before the door phone hang up itself automatically when the call from the door phone is not answered by the intercom device being called to. Path: Intercom > Call Feature> Max Dial Time. if the call Parameter set-up:
Dial In Time: enter the dial in time duration for you door phone (ranging from 30-120 sec.) for example, if you set the dial in time duration is 60 second in your door phone, then the door phone will hang up the incoming call automatically if the call is not answered by the door phone 42 in 60 seconds. 60 seconds is the dial in time duration by default. E18C Door Phone Administrator Guide Dial Out Time: enter the dial in time duration for your door phone (ranging from 5-120 sec.) for example, if you set the dial out time duration is 60 seconds in your door phone, then the door phone will hang out the call it dialed out automatically if the call is not answered by the device being called to. Note:
is available. Max dial time of device is also related with max dial time of SIP server. If using SIP account to make a call, please pay attention to the max dial time of SIP server. If the max dial time of SIP server is shorter than the max dial time of device, the shorter one 8.5.3.Audio& Video Codec Configuration for SIP Calls 8.5.3.1. Configure Audio Codec E18C door phone support four types of Codec (PCMU, PCMA, G729, G722) for encoding and decoding the the audio data during the call session. Each type of Codec vary in terms of the sound quality. You can select the specific codec with different bandwidth and sample rate flexibly according to the actual network environment. PathAccount > Advanced > Audio Codecs. 43 E18C Door Phone Administrator Guide Please refers to the bandwidth consumption and sample rate for the four types of codecs below:
Codec Type Bandwidth Sample Rate PCMA PCMU G729 G722 Consumption 64 kbit/s 64 kbit/s 8 kbit/s 64 kbit/s 8kHZ 8kHZ 8kHZ 16kHZ 8.5.3.2. Configure Video Codec This series support H.264 codec that provides a better video quality at much lower bit rate with different video quality and payload. Path Account >
Advanced > Video Codecs. Parameter set-up:
44 E18C Door Phone Administrator Guide Name: Check to select the H264 video codec format for the door phone video stream. H264 is the video codec by default. Resolution: select the code resolution for the video quality among four options:QCIF, CIF, VGA, 4CIF and 720P according to your actual network environment. The default code resolution is 4CIF. Bitrate: select the video stream bit rate (ranging from 320-2048). The greater the bitrate, the data transmitted in every second is greater in amount therefore the video will be clearer. While the default code bitrate is 2048. Payload: select the payload type (ranging from 90-118) to configure the audio codec payload. The pay load between the door phone and the corresponding intercom device should be identical. The default payload is 104. 8.6. Configure DTMF Data Transmission In order to achieve the door access via DTMF code or some other applications, you are required to properly configure DTMF in order to establish a DTMF-based data transmission between the door phone and other the third party integration. Path:Account >
Advanced > DTMF intercom device for Parameter set-up:
Mode: select DTMF mode among five options: Inband, RFC2833, Info+Inband and Info+RFC2833 based on the specific DTMF 45 E18C Door Phone Administrator Guide transmission type of the third party device to be matched with as the party for receiving signal data. How to Notify DTMFselect among four types: Disable DTMF DTMF-Relay Telephone-Event according to the specific type adopted by the third party device. You are required to set it up only when the third party device to be matched with adopts Info mode. Payload: set the payload according the the specific data transmission payload agreed on between the sender and receiver during the data transmission. 46 9.Phone Book Configuration E18C Door Phone Administrator Guide 9.1. Phone Book Configuration on the Device You can configure the contacts list in terms of adding and modifying contact groups or contacts on the device directly. To configure the phone book on the device User > Group 47 9.2. Phone Book Configuration on the Web E18C Door Phone Administrator Guide Interface 9.2.1.Manage Contact Groups on the Web Interface You can configure contact and contact groups by adding and editing them on the web interface Path: Access Control > User> Group . 9.2.2. Contact List Configuration on the Web Interface Contact can also be configured on the web interface where you can also upload the contact pictures if needed. To configure the configuration on the web Tenants > Tenants List interface. 9.2.2.1. Contact List Display Setting If you want to customize your contact list display to your desired visual preference. You can go to the web interface to do the configuration. To configure the configuration on the web interface. Path: Intercom > Basic >
48 Tenants List > Tenants List Setting. E18C Door Phone Administrator Guide Parameter Set-up:
Show Tenants of Local Group Enabled: tick or untick the check box to control the display the of the group label. If you untick the check box, then only the group tab will be displayed while the contact tab will be concealed and vice versa. Show Cloud Tenants Enabled: tick the check box to show the cloud tenants in the tenants list. And when you untick the check box, the cloud tenants will be concealed. Tenants Sort By: select ASCII Code or Room No. or Import. When you select ASCII Code, the tenants will be listed by their names in the sequence of the ASCII code. When you select Room No., the tenants will be sort according to their room numbers. Click Tenants to Dial Out: tick the check box to enable the dial-out by pressing the contact tab. When this function is enabled, you can press anywhere on the contact tab to dial out. This function will be disabled when you untick the check box, and when it is disabled, you need to press the Call icon in the middle of the tab to dial out. Hide Group Label for Contact List: tick or untick the check box to control the display the of the group label. If you untick the check box, then only the contact tab will be displayed while the group tab will be concealed and vise versa. 49 E18C Door Phone Administrator Guide 10. Relay Switch Setting 10.1.Relay Switch Setting You can unlock the door via DTMF code during the call. To do so, you are required to set up DTMF code along with relays. Path: Access Control >
Relay > Relay. Parameter Set-up:
Trigger Delay (Sec): set the relay trigger delay timing (Ranging from 1-10 Sec.) For example, if you set the delay time as 5 sec. then the relay will not triggered until 5 seconds after you press unlock tab. Hold Delay (Sec): set the relay hold delay timing (Ranging from 1-10 Sec.) For example, if you set the hold delay time as 5 Sec. then the relay will be delayed for 5 after the door is unlocked. DTMF Mode: select the number of DTMF digit for the door access control
(Ranging from 1-4 digits ) For example, you can select 1 digit DTMF code or 2-digit DTMF code etc., according to your need. 1-digt DTMF : set the 1-digt DTMF code within range from ( 0-9 and *,#). 2~4 Digits DTMF: set the DTMF code according to the DMTP Option setting. For example, you are required to set the 3-digits DTMF code if 50 DTMP Mode is set as 3-digits. E18C Door Phone Administrator Guide Relay Status: relay status is low by default which means normally closed(NC) If the relay status is high, then it is in Normally Open status(NO). Relay Name: name the relay switch according to your need. For example you can name the relay switch according to where the relay switch is located for the convenience. Only the external devices connected to the relay switch needs to be powered by powered adapters as relay switch does not supply power. Note:
Note:
If DTMF mode is set as 1 Digit DTMF , you cannot edit DTMF code in 2~4 Digits DTMF field. And if you set DTMF mode from 2-4 in 2~4 Digits DTMF field, you can not edit DTMF code in 1 Digit DTMF field. 10.2.DTMF Code Configuration DTMF codes can be configured on the door phone web interface and set up identical DTMF code on the corresponding intercom devices such as indoor monitor, which allows residents to enter the DTMF code on the soft keypad or press DTMF code attached unlock tab on the screen to unlock the door for visitors etc., during a call. Path: Account > Advanced > DTMF. Parameter Set-up:
51 E18C Door Phone Administrator Guide Mode: select DTMF type among five options: Inband, RFC2833, Info+Inband and Info+RFC2833 according to you need. DTMF Code Transport format: select among four options: Disable DTMF DTMF-Relay Telephone-Event according to your need. Payload: select the payload 96-127 for data transmission identification. The default payload is 101. Note:
Please refer to the chapter Configure DTMF Data Transmission for the specific DTMF code setting. Intercom devices involved must be consistent in the DTMF type otherwise DTMF code cannot be applied. 10.3.Web Relay Setting In additional to the relay that is connected to the device, you can also control the door access using the network-based web relay on the device and on the device web interface. 10.3.1. Configure Web Relay on the Web Interface Web relay needs to be set up on the web interface where you are required to fill in such information as relay IP address, password. And you can fill in a maximum of 50 web relay action commands for different web relay actions, which can later selected on the device screen for the specific relay action for 52 the door access control. Path: Access Control > Web Relay E18C Door Phone Administrator Guide Parameter Set-up:
Type: select among three options Disabled WebRelay and Both. Select WebRelay to enable the web relay. Select Disable to disable the web relay. Select Both to enable both local relay and web relay. IP Address: enter the we relay IP address provided by the web relay manufacturer. User Name: enter the User name provided by the web relay manufacturer. Password:
enter relay manufacturer.The passwords is authenticated via HTTP and you can define the passwords using http get in Action. the web password provided the by Web Relay Action: enter the specific web relay action command provided by the web manufacturer for different actions by the web relay. Web Relay Key: enter the configured DTMF code, when the door is unlock via DTMF code, the action command will be sent to the web relay automatically. Web Relay Extension: enter the relay extension information, which can be a SIP Account user name of an intercom device such as an indoor monitor, so that the specific action command will be sent when unlock is performed on the intercom device, while this setting is optional. And please refer to the example below:
53 http://admin:admin@192.168.1.2/state.xml?relayState=2. E18C Door Phone Administrator Guide 10.3.2. Configure Web Relay on the Device After the web relay actions is entered on the web interface, you can now select the specific number of the web relay actions to be carried for the specific resident you added for the door unlock. Path: User > User List 10.4.Relay Schedule You can set the specific relay to be always opened in specific time range during which time the door will stay open, allowing residents to gain door entry without applying any types of door access credentials to unlock the door. This feature is designed for some specific scenarios such as the time after school, or for morning work time. You are required to set the relay schedule first before applying the relay schedule to the specific relay for the door access control. Path: Access Control > Schedule 54 E18C Door Phone Administrator Guide After the relay schedule is created, you can select the relay schedule and to apply the schedule. select Path:Access control > Relay > Relay Schedule. the specific relay to which you want Note:
You can refer to the chapter 11.1 Create Door Access Schedule for the relay schedule setting as the configuration of relay schedule is identical to the 55 11. Door Access Schedule Management E18C Door Phone Administrator Guide You are required to configure and make schedule for the user-based door access via RF card, Private PIN and Facial recognition. 11.1. Configure Door Access Schedule You can create door access schedules so that they can be later conveniently applied to the door access control intended for individual user or a group of users created. More over, you can edit your door access schedule if needed. You can manage the door access schedule on the device and the devices web interface. 11.1.1. Create Door Access Schedule on the Web Interface You can create the door access schedule on the daily or monthly basis and you can also create schedule that allows you to plan for a longer period of time in addition to running the door access schedule on the daily or monthly basis. Path: Access Control > Schedule. To create a daily schedule, you can do as follows:
Parameter Setup:
56 E18C Door Phone Administrator Guide Name: enter the daily schedule name. Mode: select daily schedule. Date Time:Set up the time schedule for the validity of the door access during a day. To create a weekly schedule, you can do as follows:
Parameter Setup:
weekly basis. during a day. Name: enter the schedule name. Mode: select daily schedule. Day of Week: Select the day (s) on which door access can be valid on a Date Time:Set up the time schedule for the validity of the door access To create a longer period schedule, you can do as follows:
57 E18C Door Phone Administrator Guide Parameter Setup:
weekly basis. during a day. Name: enter the schedule name. Mode: select Normal schedule. Date Range: Set the data range of the validity of the door access. Day of Week: Select the day (s) on which door access can be valid on a Date Time:Set up the time schedule for the validity of the door access 11.1.2. Create Door Access Schedule on the Device. You can also create door access schedule on the device. Path: Schedule >
Add Schedule. 58 E18C Door Phone Administrator Guide 11.1.3. Import and Export Door Access Schedule In addition to creating door access schedule separately, you can also conveniently import or export the schedules in order to maximize your door access schedule management efficiency. Path: Access Control > Schedule. Note:
schedule. It only supports .xml format file for importing and exporting the 59 E18C Door Phone Administrator Guide 11.1.4. Edit the Door Access Schedule 11.1.4.1. Edit the Door Access Schedule on the Web Interface If you want to edit or delete your door access schedule you created, you can edit or delete the configured schedule separately or in batch on the web interface. Path: Access Control > Schedule 11.1.4.2. Edit the Door Access Schedule on the Device You can also edit or delete the door access schedule on the device. Path:
Schedule > Schedule. 60 E18C Door Phone Administrator Guide 61 12. Door Unlock Configuration E18C Door Phone Administrator Guide E18C offers you three types of door access via PIN code, NFC, RF card and Facial recognition. You can configure them on the device and web interface. More over, you can import or exporting the configured files to maximize your RF card configuration efficiency. 12.1.Configure PIN Code for Door Unlock You can create and modify both public PIN code and private PIN code for the door access on E18C door phone. 12.1.1. Configure Public PIN code You can configure and modify public PIN codes on the device and on the devices web interface. Configure public PIN code on the web interface Path: Access Control > PIN Setting > Public PIN Parameter Setup:
Enabled:Tick the checkbox to enable the Public PIN code application. PIN Code: set the PIN code with digit limit ranging from 4-8. Configure public PIN code on the device Path: Security > Public PIN. 62 E18C Door Phone Administrator Guide Public PIN code will not valid until the function is turned on. Note:
Note:
APT+PIN can only be applicable when the device is added to the Akuvox SmartPlus. 12.1.2. Configure Private PIN Code on the Device You can configure door access by Private PIN code for the resident on the device by entering the users name and the PIN code for the door access. Path: User > User List 63 12.1.3. Configure Private PIN Code on the Web Interface On the web interface, you can not only set up PIN code, but also set and select the door access schedule that you created for the validity of the PIN Code access during a certain time span you scheduled. In addition, you can set the limit for the total number of valid PIN code door access.Path:
Access Control > User. E18C Door Phone Administrator Guide 64 E18C Door Phone Administrator Guide Parameter Set-up:
User ID: enter users ID. Name:enter the user name ( residents name). Code: enter the users private PIN . After user information and PIN code is entered, you can start configuring the private PIN code for the door access. Parameter Set-up:
Relay: select the relay for the door unlock for the user. Floor NO: enter the residents floor number. Web relay: select the specific number of web relay action commands you have set up on the web interface. Schedule: select from the created door access schedule on the right box and move the one to be applied to the user(s)-specific PIN code door access to the box on the right side. 65 E18C Door Phone Administrator Guide Note:
This step is applicable to door access by RF card and facial recognition credentials as they are identical in configuration. 12.1.4. Configure Private PIN Access Mode E18C offers you two types of access modes for private PIN code access, namely PIN and APT#+PIN. Path: Access Control > PIN Setting > Private PIN Parameter Set-up:
Authorization Mode: select access mode between PIN and APT#+PIN. if you select PIN then you are only required to enter PIN code directly for the door access,while if you select APT#+PIN, then you are required to enter the Apartment Number first before entering your PIN code for the door access. 12.2.Configure RF Card for Door Unlock You can add RF card for the specific user for the door unlock on the web interface and on the device. 12.2.1. Configure RF Card on the Web Interface 66 E18C Door Phone Administrator Guide You can tap the RF card on the reader and click obtain to add RF card for the user. Path: Access Control > User > RF Card Note:
Note:
Please refer to PIN code access schedule selection for the RF card user(s)-specific door access. RF card with 13.56 MHz and 125 KHz can be applicable to the door phone for the door access. 12.2.1.1. Configure RF Card Code Format If you want to integrate with the third party intercom system in terms of RF card door access, you can change the RF card code format to be identical Path: Access Control > Card with that applied in the third party system. setting >RFID. 67 Parameter Set-up:
E18C Door Phone Administrator Guide IC/ID Card Display Mode: select the card format for the ID Card for the door access among five format options: 8H10D; 6H3D5D(W26); 6H8D; 8HN; 8HR. The card code format is 8HN by default in the door phone. 12.2.2. Configure Facial Recognition for Door Unlock 12.2.2.1. Configure Facial Recognition on the Device You can configure door access by facial recognition on the device by entering the users name and register your facial ID on the device for the door access. Path: User > User List > Add User. 68 12.2.2.2. Configure Facial Recognition on Web Interface E18C Door Phone Administrator Guide You can import the face data to the device on the web interface. Path: Access Control > User > Face. Parameter Set-up:
Status: It will show Registered when the picture uploaded conforms to the format and standard otherwise it would show Unregistered as the default. However, the status will be changed back to Unregistered if the picture uploaded is cleared when you press the Reset tab. Photo(jpg/png): select the picture with jpg or png format to be uploaded to the device and press if you want to clear the picture uploaded. Pictures to be uploaded should be in jpg or png format. 12.3. Configure Door Access Using Configured importing the E18C allows you to speedily configure user(s)-specific door access in batch by files incorporating user information, door access type, door access schedule etc., thus all the door access setting can be done at one stop, saving your time and effort from configuring the door access for users separately when users configured all-in-one door access control 69 Note:
Files. are large in number. Path: Access Control > User > User. E18C Door Phone Administrator Guide Note:
Configured file for facial recognition and the other types of configured door access file are separated with different file forms. 12.4.Edit the User(s)-specific door access data You can search user(s)-specific door access and edit the door access data on the web interface. Path:Access Control > User > User. 70 12.4.1. Unlock by QR Code E18C Door Phone Administrator Guide QR code is another option for door unlock. You need enable the QR code function before you can gain door unlock via QR code. Path:Access Control >
Relay > Open Relay via QR Code. Note:
The function should work with Akuvox cloud. For more information, please contact Akuvox technical team. 12.4.2. Unlock by Bluetooth You can also gain the door access by mobile phone with Bluetooth which is used together with Akuvox SmartPlus. You can shake the mobile phone closer to the door phone for the door access. Path: Access Control > BLE >
BLE. Parameter Set-up:
71 E18C Door Phone Administrator Guide Enabled: enable or disable the Bluetooth function. Bluetooth is turned off by default. Rssi Threshold: select the signal receiving strength from -85~-50db in absolute terms. The higher value it is, the greater strength it has. The default value is 72db in absolute terms. Open Door Interval: select the time interval between the every two Bluetooth door accesses. 12.4.3. Unlock by NFC You can also gain the door access by mobile phone with NFC which is used together with Akuvox SmartPlus. You can keep the mobile phone closer to the door phone for the door access. Path: Access Control > Card Setting>
NFC Parameter Set-up:
Enable: enable the NFC function if you want to unlock the door via NFC. 12.4.4. Unlock by HTTP Command on Web Browser You can unlock the door remotely without approaching the device physically for the door access by typing in the created the HTTP command (URL) on the web browser to trigger the relay when you are not available by the door for the door access. Path: Access Control > Relay > Open Relay via HTTP. 72 E18C Door Phone Administrator Guide Parameter Set-up:
Enable: enable the HTTP command unlock function by clicking on Enable User Name: enter the user name of the device web interface, for example Password: enter the password for the HTTP command. For example :
Please refer to the following example:
http://192.168.35.127/fcgi/do?action=OpenDoor&UserName=admin&Passw ord=12345&DoorNum=1 field. Admin. 12345. Note:
DoorNum in the HTTP command above refers to the relay number
#1 to be triggered for the door access. 12.4.5. Unlock by Exit Button by the Door When you need to open the door from inside using the exit button installed by the door, you can configure the devices Input to trigger the relay for the door access. Path: Access Control > Input > Input. 73 E18C Door Phone Administrator Guide Parameter Set-up:
Trigger Electrical Level: select the trigger electrical level options between High and Low according to the actual operation on the exit button. Action to Execute: select the method to carry out the action among four options: FTP, Email, HTTP, TFTP. Http URL: enter the URL if you select the HTTP to carry out the action. Action Delay: set up the delay time when the action is carried out. For example, if you set the action delay time at 5 seconds., then the corresponding actions will be carried out 5 minutes after your press the button. Execute Relay: set up relays to be triggered by the input. Door Status: display the status of input signal. 12.4.6. Unlock by Reception Tab In the device home screen, E18C provide residents and visitors a quick door unlock by pressing the Reception tab on the bottom of the home screen. Path:Intercom > Basic > Key Setting 74 E18C Door Phone Administrator Guide Parameter Set-up:
Reception Enabled: Tick the check box to enable the function. Name: enter the name for the Reception icon on the home screen. Number: enter the SIP/IP number to be called to after pressing the Reception icon for the door access. 12.4.7. Body Temperature Measurement for Door Access E18C provide you with an optional body temperature measurement function designed to be applied in the situation where the measurement becomes necessary for the safety of the residents and visitors etc. Residents and visitors are required to go through temperature measurement along with optional mask detection check before they are allowed for the door access. 12.4.7.1. Body Temperature Measurement Configuration You can configure the body temperature measurement function in terms of defining the normal temperature as well as making schedule for the validity 75 E18C Door Phone Administrator Guide of the function etc. Path:Access Control > Body Temperature > Measuring Body Temperature. Parameter set-up:
Mode: select either Disabled Mode Wrist or Forehead Mode for temperature measurement according to your need. The device can be installed with digital forehead and wrist temperature detector therefore you are required to set the mode properly according to your application. Mask Detection: select Disable if you want to turn off the mask detection. Select Set mask-wearing as mandatory and the device will check if the visitor is wearing a mask or not while reminding the visitor with the announcement Please wear a mask . select Display mask-wearing prompt and the device will display mask-wearing prompt only without making the the mask-wearing mandatory. Warning alarm will be triggered when the body temperature measured is detected higher than the defined normal body temperature. Normal Body Temperature: set the body temperature to the predefined body temperature as the measuring basis in either Fahrenheit or Celsius. For example if you set the temperature 37.3 degree Celsius as the normal 76 E18C Door Phone Administrator Guide temperature, then any body temperature measured higher than 37.3 degree Celsius will be deemed as abnormal temperature, while the temperature lower than 34 degree Celsius will be deemed as low body temperature. Low Temperature: set the low temperature. Action For Abnormal Body Temperature:
Action For Low Body Temperature:
Action to Execute: check the box to enable or disable the SIP/IP Call. If you want to be notified via SIP/IP call when abnormal temperature and low temperature is detected. SIP/IP Call Number: enter the SIP or IP call for the notification. The field will appear for you to fill in SIP/IP numbers when you check the box in the Action to Execute field. 77 E18C Door Phone Administrator Guide 13. Security 13.1.Tamper Alarm Setting Tamper alarm function serves as a protection against any unauthorized removal of the devices by triggering off the temper alarm on the device. Path:
Security > Basic > Temper Alarm. Parameter Set-up:
Enable: tick the check box to enable the temper alarm function. When the temper alarm goes off , you can press the Disarm tab beside the check box to clear the alarm. Key Status: temper alarm will not be triggered unless the key status is shifted from Low to High status. Note:
Note:
Disarm tab will turn gray when the temper alarm is cleared. The round rubber button at the back of the device must be in press-down status otherwise the alarm will not be fired. The round rubber button at the back of the device must be in press-down status otherwise the alarm will not be fired. 78 13.2.Voice Encryption E18C Door Phone Administrator Guide SRTP(Secure Real-time Transport Protocol) is a protocol defined on the basis of Real-time Transport Protocol. The data of the transmission protocol provides encryption, message authentication, integrity assurance and replay protection. Path: Account > Advanced > Encryption interface Parameter Set-up:
Voice Encryption(SRTP): choose Disabled, Optional or Compulsory for SRTP. If it is Optional or Compulsory, the voice during the call is encrypted, and you can grab the RTP packet to view 13.3. Motion Detection Motion Detection is often used for unattended surveillance video and automatic alarm. The images collected by the camera at different frame rates will be calculated and compared by the CPU according to a certain algorithm. You can turn enable motion detection and configure the time interval, and configure the motion detection sensitivity and notification type when the motion detection action is triggered. 13.3.1. Configure Motion Detection on the Web Interface On the device web interface, you can not only configure the time interval but also the motion detection sensitivity and notification type when the motion detection action is triggered. Path: Surveillance > Motion > Motion Detection Options interface 79 E18C Door Phone Administrator Guide Parameter Set-up:
Motion Detection Options: tick the check box to enable the motion detection function. Action to Execute: select the action to be executed ( FTPTFTP Email HTTPSIP Call) after motion detection is triggered. HTTP URL: enter the HTTP URL command which will be sent to the designated server for certain action. Time Interval: set the time interval in the same away as you do on the device. Detection Accuracy: set the detection sensitivity. The small value it is, the greater sensitivity. the default detection accuracy value is 20. the detection accuracy for Execute Relay : select the relay A or relay B to be triggered when then motion detection is triggered. You can also set the motion detection time schedule. 80 E18C Door Phone Administrator Guide 13.3.2. Configure Motion Detection on the Device You can turn on the motion detection and set up the motion detection interval on the device. Path: Advanced > Surveillance >Motion. 13.4.Security Notification Setting Security notification can be initiated as an action when the motion detection is triggered. And the security notification can be made via Email, FTP server, TFTP server, and SIP call. 13.4.1. Email Notification Setting If you want to receive the security notification via email, you can configure the Email notification on the web interface properly. Path: Setting > Action 81 E18C Door Phone Administrator Guide Parameter set-up:
Senders Email Name: enter the name of the email sender. Sender's email address: enter the senders email address from which the email notification will be sent out. Receiver's email address: enter the receivers email address. Receivers Email Name: enter the the name of the email receiver. SMTP server address:enter the SMTP server address of the sender. Port: enter the port number from which the email is sent out. SMTP user name: enter the SMTP user name, which is usually the same with senders email address. SMTP password:configure the password of SMTP service, which is same with senders email address. Email subject: enter the subject of the email. 82 E18C Door Phone Administrator Guide Email content: compile the emails contents according to your need. Email Test: click to test if the email can be sent and received. 13.4.2. FTP Notification setting If you want to receive the security notification via FTP, you can configure the FTP notification on the web interface properly. Path:Setting > Action > FTP Notification. Parameter set-up:
notification. FTP server: enter the address (URL) of the FTP server for the FTP FTP User Name: enter the FTP server user name. FTP Password: enter the FTP server password. FTP Path: enter the folder name you created in FTP server. 13.4.3. TFTP Notification Setting 83 E18C Door Phone Administrator Guide If you want to receive the security notification via TFTP, you can configure the FTP notification on the web interface properly. Path:Setting > Action > TFTP Notification. Parameter set-up:
notification TFTP Server: enter the address (URL) of the TFTP server for the TFTP 13.4.4. SIP Call Notification If you want to receive the security notification via SIP call, you can configure the FTP notification on the web interface properly. Path:Setting > Action >
TFTP Notification. Parameter Set-up:
SIP Call Number: enter the SIP call number. SIP Caller Name: enter the SIP caller Name. 13.5.Web Interface Automatic Log-out You can set up the web interface automatic log-out timing, requiring re-login by entering the user name and the passwords for the security purpose or for the convenience of operation. Path:Security > Basic > Session Time Out. 84 E18C Door Phone Administrator Guide To configure the web interface time-out, you can do as follows:
Parameter Setup:
Session Time Out Value: set the automatic web interface logout timing ranging from 60 seconds to 14400 seconds. The default value is 300. 85 14. Monitor and Image E18C Door Phone Administrator Guide 14.1.Mjpeg Image Capturing E18C allow you to capture the Mjpeg format monitoring image if needed. You can enable the Mjpeg function and set the image quality on the web interface. Path: Surveillance > MJPEG > Mjpeg Server Parameter Set-up:
Enabled: Tick the check box to enable or disable the Mjpeg service. Image Quality: select the quality for the image capturing among seven options: QCIF, QVGA, CIF, VGA, 4CIF, 720P, 1080P After the Mjpeg service is enabled, you can capture the image from the door phone using following three types of URL format:
http:// device ip:8080/picture.cgi http://device ip:8080/picture.jpg http://device ip:8080/jpeg.cgi For example, if you want to capture the jpg format image of door phone with the IP address:192.168.1.104, you can do as follows:
1. Enter http://192.168.1.104:8080/picture.jpg on the web browser 2. Press Enter key in your keyboard to capture the image. 86 E18C Door Phone Administrator Guide You can also enable the the MJPEG server on the device directly. Path:
Advanced > Surveillance > MJPEG server. 14.2.Live Stream If you want to check the real-time video from the E18C, you can go to the the device web interface to obtain the real-time video or you can also enter the correct URL on the we browser to obtain it directly. Path:Surveillance > Live Stream. 87 E18C Door Phone Administrator Guide Note:
You can also enter the correct URL (http://IP_address:8080/video.cgi) on the web browser if you want to obtain the real-time video directly without going to the web interface. 88 14.3.RTSP Stream Monitoring E18C Door Phone Administrator Guide E18C supports RTSP stream that allows intercom devices such as indoor monitor or the monitoring unit from the third party to monitor or obtain the the real time audio/ video (RTSP stream) from the door phone using the correct URL. 14.3.1. RTSP Basic Setting You are required to set up RTSP function in terms of RTSP Authorization, authentication and password etc., before you are able to use the function. Path: Surveillance > RTSP > RTSP Basic Parameter Set-up:
Enabled: Tick the check box to to turn on or turn off the RTSP function. Authorization Enabled: Tick the check box to enable the RTSP authorization. If you enable the RTSP Authorization, you are required to enter RTSP Authentication Type, RTSP Username, RTSP Password on the intercom device such as indoor monitor for authorization. RTSP Authentication Type: select RTSP authentication type between Basic and Digest. Basic is the default authentication type. 89 User Name: enter the name used for RTSP authorization. E18C Door Phone Administrator Guide Password: enter the password for RTSP authorization. You can also enable the RTSP function on the device directly. Path:
Advanced > Surveillance > RTSP Server. 14.3.2. RTSP Stream Setting the video codec format You can select for the RTSP stream for the monitoring and you can also configure video resolution and bit-rate etc. based on your actual network environment. Path:Surveillance > RTSP >
H.264 Video Parameters. 90 E18C Door Phone Administrator Guide Parameter Set-up:
Video Resolution: select video resolutions among seven options: QCIF, QVGA,CIF,VGA,4CIF,720P,1080P. The default video resolution is 720P. and the video from the door phone might not be able to be shown in the indoor monitor if the resolution is set higher than 720P. Video Framerate: 25fps is the video frame rate by default. Video Bitrate: select video bit-rate among six options: 128 kbps, 256kbps, 512 kbps, 1024 kbps, 2048 kbps, 4096 kpbs according to your network environment. The default video bit-rate is 2048 kpbs. 2nd Video Resolution2: select video resolution for the second video stream channel. While the default video solution is VGA. 2nd Video Framerate: select the video framerate for the second video stream channel. 25fps is the video frame rate by default for the second video stream channel. 2nd Video Bitrate: select video bit-rate among the six options for the second video stream channel. While the second video stream channel is 512 kpbs by default. Video Crop: select default if you want to obtained cropped video image and select Original if you want to obtain original video image. 91 E18C Door Phone Administrator Guide E18 series supports two video stream channels for H.264 codec Note:
video stream. 14.4. ONVIF Real-time video from the E18C camera can be searched and obtained by the Akuvox indoor monitor or by the third party devices such as NVR (Network Video Recorder) you can configure the ONVIF function in the door phone so that other device will be able to see the video from the door phone. Path:
Surveillance > ONVIF > Basic Setting. Parameter Set-up:
Discoverable: Tick the check box to turn on the the ONVIF mode. If you select video from the door phone camera can be searched by other devices. ONVIF mode is Discoverable by default. User Name: enter the user name. The user name is admin by default. Password: enter the password. The password is admin by default. After the setting is complete, you can enter the ONVIF URL on the third party device to view the video stream. For example: http://IP address:80/onvif/device_service 92 E18C Door Phone Administrator Guide Note:
Fill in the specific IP address of the door phone in the URL. 93 E18C Door Phone Administrator Guide 15. Logs 15.1. Call Logs If you want to check on the calls inclusive of the dial-out calls , received calls and missed calls in a certain period of time, you can check and search the call log on the device web interface and export the call log from the device if needed. Path:Intercom > Call Log Call History: select call history among four options: All, Dialed Received Missed for the specific type of call log to be displayed. Parameter Set-up:
15.2.Door Logs If you want to search and check on door access history, you can search and 94 E18C Door Phone Administrator Guide check the door logs on the device web interface. Path: Access Control > Door Log. Parameter Set-up:
log function. snapshot captured. Save Door Log Enabled: Tick the check box to turn on or turn off the door Save Picture Enabled: enable it if you want to save the door open Export Picture Enabled: enable it if you want export the door log with snapshot picture captured. Status: select between Success and Failed options to search for successful door accesses or Failed door accesses. Time: select the specific time select the specific time span of the door logs you want to search, check or export. Name/Code: select the Name and Code options to search door log by the name or by the PIN code. Action: click to display the picture captured. 95 15.3.Temperature Log E18C Door Phone Administrator Guide If you want to search and check on temperature log, you can search and check the logs on the device web interface. Path: Access Control >
Temperature Log Parameter Set-up:
temperature Log Save Door Log Enabled: Tick the check box to turn on or turn off the Save Picture Enabled: enable it if you want to save the temperature measuring snapshot. Export Picture Enabled: enable it if you want export the temperature log with snapshot picture captured. Time: select the specific time select the specific time span of the temperature log you want to search, check or export. Action: click to display the picture captured. 15.4.Export Logs You can export door logs, call logs and temperature logs if needed. Path:
Advanced > Export Log. 96 E18C Door Phone Administrator Guide 97 16. Debug E18C Door Phone Administrator Guide 16.1.System Log for Debugging System log in the door phone can be used for debugging purpose. If you want to export the system out to a local PC or to a remote server for debugging , you can set up the function on the web interface. Path:
Upgrade >Diagnosis > System Log. Parameter Set-up:
LogLevel: select log levels from 1 to 7 levels. You will be instructed by Akuvox technical staff about the specific log level to be entered for debugging purpose. The default log level is 3, the higher the level is 5, the more complete the log is 7. Export Log: click the Export tab to export temporary debug log file to a local PC. Remote System Log Enabled: tick the checkbox to enable the function. Remote System Server: enter the remote server address to receive the the device log. And the remote server address will be provide by Akuvox technical support. 98 16.2.PCAP for Debugging E18C Door Phone Administrator Guide PCAP in E18C is used to capture the data package going in and out of the devices for debugging and troubleshooting purpose. You can set up the PCAP on the device web interface properly before using it. Path:
Upgrade >Diagnosis > PCAP. Parameter Set-up:
Specific Port: select the specific ports from 1-65535 so that only the data packet from the specific port can be captured. You can leave the field blank by default. PCAP: click Start tab and Stop tab to capture the a certain range of data packets before clicking Export tab to export the data packets to you Local PC. PCAP Auto Refresh: select Enable or Disable to turn on or turn off the PCAP auto fresh function. If you set it as Enable then the PCAP will continue to capture data packet even after the data packets reached its 1M maximum in capacity. If you set it as Disable the PCAP will stop data packet capturing when the data packet captured reached the maximum capturing capacity of 1MB. 16.3.User Agent SIP user agent (UA) is an endpoint device that supports SIP, which is used to establish connections an enable session between two endpoint devices. And a UA is comprised of UAC (User Agent Client) and UAS (User Agent server) with the UAC used to issue requests and UAS used to issue response. UA 99 E18C Door Phone Administrator Guide acts as a SIP service provider for the specific user (device). You can customize user agent field in the SIP message. if user agent is set to specific value, users can see the information from PCAP. If user agent is blank, by default, users can see the company name Akuvox, model number and firmware version from PCAP. Path: Account > Advanced > User Agent interface. Parameter Set-up:
User Agent: support to enter another specific value, Akuvox is by default. 100 17. Firmware Upgrade E18C Door Phone Administrator Guide E18C can be upgraded on the device and on the device web interface. Upgrade the device on the web interface Path: Upgrade > Basic. Upgrade the device on the device Path:Advanced > Upgrade. 101 E18C Door Phone Administrator Guide Note:
When you insert the SD card, you are required to add a .rom file at the root directory and change the file name to update.com. 102 18. Backup E18C Door Phone Administrator Guide Configuration files and device data can be imported to or exported out of the device to your local PC on the device web interface if needed. Back up data on the web interface Path: Upgrade > Diagnosis > Others Back up data on the device You need to insert the SD card to the device for the backup. Path: Advanced > Backup&Restore Parameter Set-up:
Backup Options: select Only User Data or All Data which is the default setting. Select All data when you want to back up user, group schedule data, and configuration data exclusive of all type of logs. Select Only User Data if you only want to back up user and schedule data. 103 E18C Door Phone Administrator Guide Note:
SDHC and SDXC SD card with FAT32 format are supported. 104 19. Auto-provisioning E18C Door Phone Administrator Guide Configurations and upgrading on E18C can be done on the web interface via one-time via configuration files, thus saving you from setting up configuration needed one by one manually on the door phone. auto-provisioning provisioning scheduled auto-
and 19.1. Configuration Files for Auto-provisioning Configuration files have two formats for the auto-provisioning. one is the general configuration files used for the general provisioning and other one is the MAC-based configuration provisioning. The difference between the two types of configuration files is shown as below:
General configuration provisioning: a general file is stored in a server from which all the related devices will be able to download the same configuration file to update parameters on the devices. For example r000000000018.cfg. MAC-based configuration provisioning: MAC-based configuration files is used for the auto-provisioning on a specific device as distinguished by its unique MAC number. And the configuration files named with device MAC number will be matched automatically with the device MAC number before being downloaded for the provisioning on the specific device. Note:
If a server has these two types of configuration files, then IP devices will first access the general configuration files before accessing the MAC-based configuration files. 105 19.2.AutoP Schedule E18C Door Phone Administrator Guide Akuvox provides you with different Autop methods that enable the door phone to perform provisioning for itself in a specific time according to your schedule. Path: Upgrade > Advanced > Automatic Autop. Parameter Set-up:
Power On: select Power on, if you want the device to perform Autop every time it boots up. Repeatedly: select Repeatedly, if you want the device to perform autop according to the schedule you set up. Power On + Repeatedly: select Power On + Repeatedly if you want to combine Power On Mode and Repeatedly mode that will enable the device to perform Autop every time it boots up or according to the schedule you set up. Hourly Repeat: select Hourly Repeat if you want the device to perform Autop every hour. 19.3.PNP Configuration Plug and Play (PNP) is a combination of hardware and software support that enables a computer system to recognize and adapt to hardware configuration changes with little or no intervention by a user. Path:
configuration on web Upgrade > Advanced > PNP Option . 106 E18C Door Phone Administrator Guide 19.4.DHCP Provisioning Configuration Auto-provisioning URL can also be obtained using DHCP option which allows device to send a request to a DHCP server for a specific DHCP option code. If you wan to use Custom Option as defined by users with option code range from 128-255), you are required to configure DHCP Custom Option on the web interface. Path: Upgrade > Advanced > DHCP Option. Note:
TFTP server. The custom Option type must be a string. The value is the URL of 107 E18C Door Phone Administrator Guide Parameter set-up:
Custom Option: enter the DHCP code that matched with corresponding the find the configuration file server for URL so that device will configuration or upgrading. DHCP Option 66: If none of the above is set, the device will automatically use DHCP Option 66 for getting the upgrade server URL. This is done within the software and the user does not need to specify this. To make it work, you need to configure the DHCP server for the option 66 with the update server URL in it. DHCP Option 43: If the device does not get an URL from DHCP Option 66, it will automatically use DHCP Option 43. This is done within the software and the user does not need to specify this. To make it work, you need to configure the DHCP server for the option 43 with the update server URL in it. Note:
r0000000000xx.cfg The general configuration file for the in-batch provisioning is with the example format in total while the MAC-based r000000000915.cfg (10 zeros configuration file for the specific device provisioning is with the format MAC example 0C110504AE5B.cfg. device.cfg, Address taking E18 the for an as of 19.5.Static Provisioning Configuration You can manually set up a specific server URL for downloading the firmware or configuration file. If an autop schedule is set up, the door phone will perform the auto provisioning on a specific timing according to autop In addition, TFTP, FTP, HTTP, and HTTPS are the schedule you set up. 108 E18C Door Phone Administrator Guide protocols that can be used for upgrading the device firmware and configuration. Path:Upgrade > Advanced > Automatic Autop. Parameter set-up:
URL: set up tftphttphttpsftp server address for the provisioning. User Name: set up a user name if the server needs an user name to be accessed to otherwise leave it blank. Password: set up a password if the server needs a password to be accessed to otherwise leave it blank. Common AES Key: set up AES code for the intercom to decipher general Auto Provisioning configuration file. AES Key (MAC): set up AES code for the intercom to decipher the MAC-based auto provisioning configuration file. Note:
AES is one type of encryption, it should be configured only when the config file is encrypted with AES, otherwise leave the field blank. 109 E18C Door Phone Administrator Guide Note:
Server Address format:
TFTP: tftp://192.168.0.19/
FTP: ftp://192.168.0.19/
ftp://username:password@192.168.0.19/(requires a user name
(allows anonymous login) and password) HTTP: http://192.168.0.19/ (use the default port 80) http://192.168.0.19:8080/ (use other ports, such as 8080) HTTPS: https://192.168.0.19/ (use the default port 443) Tip:
Akuvox do not provide user specified server. Please prepare TFTP/FTP/HTTP/HTTPS server by yourself. 110 20. Integration with Third Party Device E18C Door Phone Administrator Guide 20.1.Integration via Wiegand The door phone Wiegand interface is used to connect the door phone to the third party devices for the data transmission via weigand protocol. If you want to integrate the E18C door phone with the third party devices via Wiegand, you can configure the Wiegand on the web interface. Path: Device >
Wiegand > Wiegand. Parameter set-up:
Wiegand Display Modeselect Wigand Card code format among 8H10D;
6H3D5D; 6H8D; 8HN; 8HR; RAW. Wiegand Card Reader Mode: set the wiegand data transmission format among three options: Wiegand 26, Wiegand 34, Wiegand 58. The transmission format should be identical between the door phone and the device to be integrated. Wiegand Input Data Orderset the Wiegand input data sequence between Normal and Reversed if you select Reversed then the input card number will be reversed an vice versa. Wiegand Output Data Order: set the Wiegand output data sequence 111 E18C Door Phone Administrator Guide between Normal and Reversed if you select Reversed then the input card number will be reversed an vice versa. Wiegand Output CRC: Tick to enable the parity check function to ensure that signal-based data can be transmitted correctly according to the established data transmission format. 20.2. Integration via RS485 RS485 is a physical interface used for two way data transmission between the two device. And RS485 Integration mode should be configured properly on the door phones web interface before you can implement the integration between the door phone and the third party devices. Path:Device > RS485 >
RS485 List. Parameter Set-up:
RS485 List: select integration mode between two options: None , OSDP, the detail for the two options will be provided in the following chart. NO. Integration Mode Description 1 2 None OSDP None OSDP Mode, then the RS485 If you select integration will be disabled. then the If you Select integration communication between the E18 series door phone and the third party device is via OSDP protocol. You are required to check for the device integration protocol and make sure if they use the same that integration protocol. 112 E18C Door Phone Administrator Guide 20.3. OSDP Setting OSDP (Open Supervised Device Protocol ) is standard for access control communications designed to achieve two way communication among the devices over networks. If you choose OSDP integration mode, you can not only check for OSDP status but also obtain the authentication from the third party devices for various applications such as door access etc. Path:Device > RS485 > OSDP Advance Setting. Parameter Set-up:
Connect Status: indicate OSDP based communication status. Send by: select in what way you want to send out the card number if you select among three options: OSDP, Wiegand and None. OSDP then the card number will be sent out to the third party devices via RS485. if you select Wiegand then the card number will be sent out via wiegand. If you select None then the card number will not be sent out but retained in the system. Note:
the RS485 list field. Dummy card numbers can not be sent if OSDP is not selected in 20.4.Integration via HTTP API HTTP API is designed to achieve an network-based integration between the third party device with the Akuvox intercom device. You can configure the 113 HTTP API function on the web interface. Path: Security > HTTP API. E18C Door Phone Administrator Guide Parameter Set-up:
HTTP API Enable enable or disable the HTTP API function for the third party integration. For example, if the function is disabled any request to initiate the integration will be denied and be returned HTTP 403 forbidden status. Authorization Mode: select among four options: None WhiteList Basic, Digest for authorization type, which will be explained in detail in the following chart. Username: enter the user name when Basic and Digest authorization mode is selected. The default user name is Admin. Password: enter the password when Basic and Digest authorization mode is selected. The default user name is Admin. 1st IP- 5th IP: enter the IP address of the third party devices when the WhiteList authorization is select for the integration. Please refer to the following description for the Authentication mode 114 Authorization NO. Description E18C Door Phone Administrator Guide Mode None Normal WhiteList Basic Digest 1 2 3 4 5 No authentication is required for HTTP API as it is only used for demo testing. This mode is used by Akuvox developer only. If this mode is selected, you are only required in the IP address of the third party to fill device for the authentication. The whitelist is suitable for operation in the LAN. If this mode is selected, you are required to fill in the User name and the password for the authentication.In Authorization field of HTTP request header, use Base64 encode method to encode of username and password. Password encryption method, only supports MD5. MD5( Message-Digest Algorithm) In Authorization field of Http request header:
WWW-Authenticate:Digest realm="HTTPAPI",qop="auth,auth-int",nonce="
xx", opaque="xx". 6 Token This mode is used by Akuvox developer only. 115 20.5.Power Output Control E18C Door Phone Administrator Guide E18C can serve as a power supply for the external relays. Path: Access Control > Relay >12V Power Output. Parameter Set-up:
Relay ID: Select the relay to be powered by E18C. 12V Power Output: select Disabled to disable the power output function;
select Always to enable the access controller to provide continuous power to the third party device. Select Triggered By Open Relay if you want the E18C to provide power to the third party device via 12 output and GND interface during the timeout when the relays status is shifted from low to high. Time Out (Sec): select the the power supply time duration after the relay is triggered. Three options: 3, 5, 10. It is 3 seconds by default. The power output is 12V , and the maximum output amperage is 0.8A. 116 21. Password Modification E18C Door Phone Administrator Guide On the device web interface, you can set and change both the System PIN Code for accessing the device setting and login password for accessing the web interface. In addition, you can also select the user role when setting passwords. Set and change web interface login password. Path:Security > Basic > Web Password Modify. Set and change system PIN code. Path:Security > Basic > Web Password Modify. 117 22. System Reboot&Reset E18C Door Phone Administrator Guide 22.1.Reboot If you want to restart the device, you can operate it on the device web interface as well. More over, you can set up schedule for the device to be restarted. Path: Upgrade > Basic To set up the device restart schedule, you can go to : Upgrade > Advanced >
Reboot Schedule. 118 E18C Door Phone Administrator Guide 22.2.Reset the device to the factor setting and reset the device You can reset configuration to the default configuration setting on the device and on the device web interface. To Reset the device on the device web interface Path: Upgrade > Basic To Reset the device on the device Path: Advanced > Reset. 119 E18C Door Phone Administrator Guide 120 23. Abbreviations E18C Door Phone Administrator Guide ACS: Auto Configuration Server Auto: Automatically AEC: Configurable Acoustic and Line Echo Cancelers ACD: Automatic Call Distribution Autop: Automatical Provisioning AES: Advanced Encryption Standard BLF: Busy Lamp Field COM: Common CPE: Customer Premise Equipment CWMP: CPE WAN Management Protocol DTMF: Dual Tone Multi-Frequency DHCP: Dynamic Host Configuration Protocol DNS: Domain Name System DND: Do Not Disturb DNS-SRV: Service record in the Domain Name System FTP: File Transfer Protocol GND: Ground HTTP: Hypertext Transfer Protocol HTTPS: Hypertext Transfer Protocol Secure Socket Layer IP: Internet Protocol ID: Identification IR: Infrared LCD: Liquid Crystal Display LED: Light Emitting Diode MAX: Maximum POE: Power Over Ethernet 121 PCMA: Pulse Code Modulation A-Law PCMU: Pulse Code Modulation -Law PCAP: Packet Capture PNP: Plug and Play RFID: Radio Frequency Identification RTP: Real-time Transport Protocol RTSP: Real Time Streaming Protocol MPEG: Moving Picture Experts Group MWI: Message Waiting Indicator NO: Normal Opened NC: Normal Connected NTP: Network Time Protocol NAT: Network Address Translation NVR: Network Video Recorder ONVIF: Open Network Video Interface Forum SIP: Session Initiation Protocol SNMP: Simple Network Management Protocol STUN: Session Traversal Utilities for NAT SNMP: Simple Mail Transfer Protocol SDMC: SIP Devices Management Center TR069: Technical Report069 TCP: Transmission Control Protocol TLS: Transport Layer Security TFTP: Trivial File Transfer Protocol UDP: User Datagram Protocol URL: Uniform Resource Locator VLAN: Virtual Local Area Network WG: Wiegand E18C Door Phone Administrator Guide 122 24. FAQ E18C Door Phone Administrator Guide Q1: How to obtain IP address of R2X A1: For devices with single button - E21/ R20/ R23/ R26:
the statue LED turns blue and it will enter While E21/ R20/ R23/ R26 power up normally, hold the call button for 5 seconds after into IP the IP address will be announcement mode. announced repeatedly. Press call button again to quit the announcement mode. In announcement mode, For devices with multiple numeric keyboard - R27:
While R27 power up normally, press *2396# to enter home screen and press 1 to go to system Information screen to check the IP address. For devices with touch screen - R29:
While R29 power up normally, in the dial interface, press 9999, Dial key, 3888 and OK to enter the system setting screen. Go to info screen to check the IP address. Common method:
Using Akuvox IP Scanner to search Akuvox devices in the same LAN network. Q2: Do Akuvox devices support opus codec?
A2: For now, only Akuvox Android video IP phone R48G can support Opus audio codec. Q3: What is the supported temperature range for akuvox doorphone?
A3: R20/E21/R26/R23/Standard R27/Standard R29 -- 14 to 112F (-10 to 45C) R27/R29 with heating supporting --- 40 degrees R28 -- (-40C~55C ) Indoorphone -- 14 to 112F (-10 to 45C) IPPhone -- 32~104F(0~40C) 123 E18C Door Phone Administrator Guide Q4: Do Akuvox devices support Modbus protocol?
A4: No. Q5Failure in importing the R29 face data to another R29 using the exported face data . A5Please confirm the following steps The import format is zip;
1. After you export , you need to unzip the .tgz folder , then make the unziped folrder into .zip again. Q55: Which version of ONVIF does R20 and R29 support?
A55: Onvif 18.04 profiles door phones Q6: Do iClass,iClassSE,HID Mifare, HID DESFire,HID SEOS A6: Sorry, they are not supported. They need to be implemented via hardware modifications. types? Prox, support Legacy these card Q7: How to confirm whether my device is hardware version 1 or hardware version 2?
A7: 1.Label Hardware version 1 Hardware version 2 124 E18C Door Phone Administrator Guide Firmware Version Hardware version The firmware is different between hardware version1 and hardware version 2. Go to Web-Status -Firmware Version. 20.X.X.X is hardware version 1. 220.X.X.X is hardware version 2. The firmware is different between hardware version1 and hardware version 2. Go to Web-Status -Firmware Version. If the hardware version is 220.x, then the device is hardware version 2. 125 25. Contact Us E18C Door Phone Administrator Guide For more information about the product, please visit us at www.akuvox.com or feel free to contact us by Sales email: sales@akuvox.com Technical support email: support@akuvox.com Telephone: +86-592-2133061 ext.7694/8162 We highly appreciate your feedback about our products. 126
1 2 3 4 | ID Label and Label Location | ID Label/Location Info | 221.22 KiB | June 29 2022 |
58.5mm >
Akuvox Model E180 cez ii i i OE HTH 08 06 09Z9r 3 Dp g e g
c=) A
) 5 5 oe PPR ROP TaN Omen beara vee bat alu eT |
08 OZ 09 0S OF OF Oz 01 99Z06 08 OZ 09 0S OF OE 0z 01 90] 06 7 Of 02 OL ogersisa 3 Isog
1 2 3 4 | Attestation Letter | Attestation Statements | 73.46 KiB | June 29 2022 |
Company: AKUVOX (XIAMEN) NETWORKS CO., LTD. Add: 10/F, No.56, Software Park II , Xiamen, China Tel: 086-0591-83057798 Fax: 086-0591-83057798 Email: yang@akuvox.com Date: 2022-06-15 To:
Attestation FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 We, AKUVOX (XIAMEN) NETWORKS CO., LTD., hereby declare that our product Door Phone, FCC ID: 2AHCR-E18CV1. Its module K016-CW43-SW supports 2.4GWIFI, Bluetooth function, but for this device, we only active BDR,EDR,BLE 1M, then BLE 2M and 2.4G WIFI were shielded by software. Please contact me if you have any question. Sincerely Yours, Clients signature Printed Name: Bo Yang Title: Manager
1 2 3 4 | FCC Long Term Confidential Authorization Form | Cover Letter(s) | 23.44 KiB | June 29 2022 |
AKUVOX (XIAMEN) NETWORKS CO., LTD. Add: 10/F, No.56, Software Park II , Xiamen, China Tel: 086-0591-83057798 Fax: 086-0591-83057798 Email: yang@akuvox.com Date: 2022-06-10 FEDERAL COMMUNICATIONS COMMISSIONS Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 FCC Confidential Authorization Subject: Confidentiality Request regarding application for certification of FCC ID:2AHCR-E18CV1 In accordance with Sections 0.457 and 0.459 of the Commissions Rules, AKUVOX (XIAMEN) NETWORKS CO., LTD. hereby requests long-term confidential treatment of information accompanying this application as outlined below:
Block Diagram Schematics Operation Description The above materials contain proprietary and confidential information not customarily released to the public. The public disclosure of these materials provides unjustified benefits to its competitors in the market. Sincerely, Signature:
Printed Name: Bo Yang Title: Manager QA-FR-171-A
1 2 3 4 | Power of Attorney Letter | Cover Letter(s) | 18.99 KiB | June 29 2022 |
Company: AKUVOX (XIAMEN) NETWORKS CO., LTD. Add: 10/F, No.56, Software Park II , Xiamen, China Tel: 086-0591-83057798 Fax: 086-0591-83057798 Email: yang@akuvox.com FCC Authorization Date: 2022-06-10 FEDERAL COMMUNICATIONS COMMISSION Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Subject: Agent Authorization To whom it may concern:
We , AKUVOX (XIAMEN) NETWORKS CO., LTD., Hereby authorizes China Certification ICT Co., Ltd (Dongguan) to act on its behalf in all matters relating to application for Equipment authorization, including the signing of all documents relating to these matters. All acts carried out by China Certification ICT Co., Ltd (Dongguan) on our behalf shall have the same effect as our own action. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, This authorization is valid until further written notice from the applicant. 21 U.S.C. 862. Sincerely Yours, Clients signature Printed Name: Bo Yang Title: Manager QA-FR-170-B
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2022-06-29 | 2402 ~ 2480 | DTS - Digital Transmission System | Original Equipment |
2 | 13.56 ~ 13.56 | DXX - Part 15 Low Power Communication Device Transmitter | ||
3 | JAB - Part 15 Class B Digital Device | |||
4 | 2402 ~ 2480 | DSS - Part 15 Spread Spectrum Transmitter |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 2 3 4 | Effective |
2022-06-29
|
||||
1 2 3 4 | Applicant's complete, legal business name |
AKUVOX (XIAMEN) NETWORKS CO., LTD.
|
||||
1 2 3 4 | FCC Registration Number (FRN) |
0025226762
|
||||
1 2 3 4 | Physical Address |
10/F, No.56, Software Park II
|
||||
1 2 3 4 |
Xiamen, N/A
|
|||||
1 2 3 4 |
China
|
|||||
app s | TCB Information | |||||
1 2 3 4 | TCB Application Email Address |
b******@baclcorp.com
|
||||
1 2 3 4 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
1 2 3 4 |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
|||||
app s | FCC ID | |||||
1 2 3 4 | Grantee Code |
2AHCR
|
||||
1 2 3 4 | Equipment Product Code |
E18CV1
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 2 3 4 | Name |
B**** Y******
|
||||
1 2 3 4 | Telephone Number |
086-0********
|
||||
1 2 3 4 | Fax Number |
086-0********
|
||||
1 2 3 4 |
y******@akuvox.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 2 3 4 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 2 3 4 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 2 3 4 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 2 3 4 | Equipment Class | DTS - Digital Transmission System | ||||
1 2 3 4 | DXX - Part 15 Low Power Communication Device Transmitter | |||||
1 2 3 4 | JAB - Part 15 Class B Digital Device | |||||
1 2 3 4 | DSS - Part 15 Spread Spectrum Transmitter | |||||
1 2 3 4 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Door Phone | ||||
1 2 3 4 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 2 3 4 | Modular Equipment Type | Does not apply | ||||
1 2 3 4 | Purpose / Application is for | Original Equipment | ||||
1 2 3 4 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | Yes | ||||
1 2 3 4 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 2 3 4 | Grant Comments | Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. | ||||
1 2 3 4 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 2 3 4 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 2 3 4 | Firm Name |
CHINA CERTIFICATION ICT CO., LTD (DONGGUAN)
|
||||
1 2 3 4 | Name |
T**** O****
|
||||
1 2 3 4 | Telephone Number |
0086 ********
|
||||
1 2 3 4 |
q******@ccttt.com.cn
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | CC | 2402.00000000 | 2480.00000000 | 0.0050000 | |||||||||||||||||||||||||||||||||||
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
2 | 1 | 15C | CC | 0.125 | 0.125 | ||||||||||||||||||||||||||||||||||||
2 | 2 | 15C | CC | 13.56 | 13.56 | ||||||||||||||||||||||||||||||||||||
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
3 | 1 | 15B | CC | ||||||||||||||||||||||||||||||||||||||
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
4 | 1 | 15C | CC | 2402.00000000 | 2480.00000000 | 0.0050000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC