C315W Indoor Monitor User Manual About This Manual Thank you for choosing Akuvoxs C315W indoor monitor. This manual is intended for end users, who need to use and configure the indoor monitor. It provides an overview of the most essential functions and features of the product. The document is suitable for 115.1.2.2xx version. Please visit our forum or consult technical support for any new information or latest firmware. Note: Please refer to universal abbreviation form in the end of the document when you meet any abbreviation letter in the whole user manual. FCC Caution:
Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment . This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This equipment should be installed and operated with minimum distance 20cm between the radiator &you body. Content 1. Product overview ........................................................................................................................................................................... 1 1.1. Product Description ................................................................................................................................................................ 1 1.2. Power connection ................................................................................................................................................................... 2 2. Daily use ......................................................................................................................................................................................... 3 2.1. Making a call ........................................................................................................................................................................... 3 2.1.1. Calling from digital keypad ............................................................................................................................................ 3 2.1.2. Calling from phonebook ................................................................................................................................................. 4 2.1.3. Calling from call log ....................................................................................................................................................... 5 2.2. Receiving a call ....................................................................................................................................................................... 6 2.2.1. Receiving a incoming call .............................................................................................................................................. 6 2.2.2. During the session ......................................................................................................................................................... 6 2.3. Live view ................................................................................................................................................................................. 7 2.3.1. Checking the monitor ..................................................................................................................................................... 8 2.4. Message(s) ............................................................................................................................................................................. 9 2.4.1. Text Message ................................................................................................................................................................ 9 2.4.2. Creating a message .................................................................................................................................................... 10 2.5. Arming ................................................................................................................................................................................... 11 2.5.1. Arming Mode ............................................................................................................................................................... 11 2.5.2. Disarm Code ................................................................................................................................................................ 12 2.5.3. Alarm Log .................................................................................................................................................................... 13 2.5.4. Status ........................................................................................................................................................................... 14 C315W User Manual Figure 1.1-1 1. Product overview 1.1. Product Description C315W is a Android-based IP indoor monitor with a touch screen. It incorporates audio communications, access control sensor arming and obtaining video stream from door phone or IP camera. Its finely-tuned Android OS allows for better suit the habit of usage of local people. Powered by it, C315W multiple ports, such as I/O and Bell ports, can be used to easily integrate external Arming systems, such as bell controller and fire alarm detector, helping create a holistic control of home safety and access control and giving occupants a great sense of security. It is applicable to multi-storey residential buildings or villas. 1 C315W User Manual 1.2. Power connection Ethernet(POE): Ethernet(POE) connector which can provide both power and network connection. RJ45(PON): This is a special connector to provide power and network for E10 series. 12V/GND: External power supply terminal if POE is not available. RS485-A/B: RS485 terminal. Bell/GND: Connect a simple two-wire door bell. RelayA/B (NO/COM/NC): Relay control terminal. IO1-IO8/GND: Connect with different alarm detector for 8 security zones. Note: The general indoor monitor interface diagram is only for reference. 2 Figure 1.2-1 interface Figure 1.2-2 General interface C315W User Manual 2. Daily use 2.1. Making a call There are two ways to make a call from the indoor monitor to other units. Call from Intercom, Contact or Call log. 2.1.1. Calling from digital keypad Figure 2.1-1 Call method Press Intercom in home page to enter the dial interface to dial the number directly. Choose a suitable phone account for the outgoing call. Note: C315W support 2 accounts. Please refer to admin guide for more account settings. Enter the number to call on the digital keypad Tap the dial key, users can choose Audio Call or Video Call
. to dial out. 3 Figure 2.1.1-1 Dial number C315W User Manual 2.1.2. Calling from phonebook Enter the contact interface to make a call. C315W supports fuzzy matching query
.To search the list by number or alphabet. Scroll up or down the pre-imported contact list to choose the contact you want to call. Select the right phone number from the contact. Click Audio or Video mode to call out. 4 Figure 2.1.1-1 Phonebook C315W User Manual 2.1.3. Calling from call log Press the Miss Call note to enter the call log interface. You can also enter Intercom interface to check call log . Then choose audio or video call to dial out. Figure 2.1.3-1 Miss call note Figure 2.1.3-2 Miss log 5 C315W User Manual 2.2. Receiving a call 2.2.1. Receiving a incoming call There will be a video preview in this window, when you receive a incoming call. Press Video or Audio key to pick up the incoming call. Press Cancel to reject the incoming call. Press + or - to adjust the ring tone volume in the right side. Figure 2.2.1-1 Receive call 2.2.2. During the session The call video will be showed in this window. Press Mute key to mute the current call. Tap Capture to capture the screenshot of the visitor. Press Unlock to unlock the corresponding door phone. Tap Switch to change the video or audio call. Press Cancel icon to hang up the current call. Figure2.2.1-1 During session 6 C315W User Manual 2.3. Live view Live view feature is used to monitor the real-time video from the IPC or door phone anytime. Click Live View in home page. 7 Figure 2.3-1 Live view C315W User Manual 2.3.1. Checking the monitor Choose the outdoor devices from the list . The real-time video from the door phone or IPC will show in the screen . Press Unlock to open the door which connected with door phone. Press Capture to take a photo from the outdoor devices. Press Cancel to exit the monitor. Press List button in the bottom right corner to switch the different outdoor videos. Press the Monitor list in the right side to choose the outdoor videos. Figure 2.3.1-1 Live view list Figure 2.3.1-2 Live view video 8 C315W User Manual 2.4. Message(s) Press Message to enter the message interface. Or there will be a notification if there is any new message, click the New Message notification to check directly. 2.4.1. Text Message By entering the message interface, it is text message list. Users can check the message you received or what you sent here. Select a message to check the content. Hold the one of existed messages , it will show up delete prompt. Click Select All to delete all messages. Click Delete to remove the message you choose. Click Cancel key to cancel the deletion. 9 Figure 2.4-1 Message Figure 2.4-1 Edit message C315W User Manual 2.4.2. Creating a message Press New key Choose the contact from the contact list or enter the to create a new message. destination number manually . Choose the frequently-used message , such as Hello, Help. Or input the message content you want to send . Select line 1 or line 2 account to send out. Note: C315W support 2 accounts. Please refer to admin guide for more account settings. Press Send key to send. Figure 2.4.2-1 Create message Figure 2.4.2-2 Create message 10 C315W User Manual 2.5. Arming Tap Arming to enter the Arming interface. C315W supports 4 mode, they are Home mode, Night mode, Away mode and disarm mode. 2.5.1. Arming Mode Go to the path Arming - Arming mode. Users can see all of the 8 zones and corresponding sensor types. Slide down to check more information in this interface. Adjust Defence delay time. It means when you change to the arming mode from other modes, there will be 30 seconds delay time. To setup the Alarm delay. It means when the sensor triggered, there will be 90 seconds delay time to announce the notification. 11 Figure 2.5-1 Arming Figure2.5-1 Arming mode C315W User Manual The Status the corresponding zone means whether the zone is available or not. Press Save in the top right corner to save the modification. 2.5.2. Disarm Code Go to the path Arming - Disarm Code to enter the disarm code settings interface. Users can modify the disarm code here. Enter the original disarm code first, it is 0000 as default. Enter the new disarm code . Enter the new disarm code again for confirming. Press Save to save the modification. 12 Figure 2.5.2-1 Disarm code C315W User Manual 2.5.3. Alarm Log Go to the path Arming - Alarm Log to enter the alarm log interface. Users can see the alarm log here including location, zone, zone type and alarm time. Hold a alarm log ,it will show up delete prompt. Press Select All and click Delete to delete all alarm log. Press Cancel to cancel to delete. Figure 2.5.3-1 Alarm log Figure 2.5.3-2 Edit alarm log 13 C315W User Manual 2.5.4. Status Go to the path Arming - Zone status to enter the zone status interface. Users can check the status of every zone, including location, zone type, trigger mode and status. Figure2.5.3-1 Zone status 14 C315W User Manual Abbreviations ACS: Auto Configuration Server Auto: Automatically DNS-SRV: Service record in the Domain Name System FTP: File Transfer Protocol AEC: Configurable Acoustic and Line Echo Cancelers GND: Ground ACD: Automatic Call Distribution Autop: Automatical Provisioning AES: Advanced Encryption Standard BLF: Busy Lamp Field COM: Common CPE: Customer Premise Equipment CWMP: CPE WAN Management Protocol DTMF: Dual Tone Multi-Frequency DHCP: Dynamic Host Configuration Protocol DNS: Domain Name System DND: Do Not Disturb HTTP: Hypertext Transfer Protocol HTTPS: Hypertext Transfer Protocol Secure IP: Internet Protocol ID: Identification IR: Infrared LCD: Liquid Crystal Display LED: Light Emitting Diode MAX: Maximum POE: Power Over Ethernet PCMA: Pulse Code Modulation A-Law PCMU: Pulse Code Modulation -Law 15 C315W User Manual PCAP: Packet Capture PNP: Plug and Play RFID: Radio Frequency Identification RTP: Real-time Transport Protocol RTSP: Real Time Streaming Protocol MPEG: Moving Picture Experts Group MWI: Message Waiting Indicator NO: Normal Opened NC: Normal Connected NTP: Network Time Protocol NAT: Network Address Translation NVR: Network Video Recorder ONVIF: Open Network Video Interface Forum SIP: Session Initiation Protocol SNMP: Simple Network Management Protocol STUN: Session Traversal Utilities for NAT SNMP: Simple Mail Transfer Protocol SDMC: SIP Devices Management Center TR069: Technical Report069 TCP: Transmission Control Protocol TLS: Transport Layer Security TFTP: Trivial File Transfer Protocol UDP: User Datagram Protocol URL: Uniform Resource Locator VLAN: Virtual Local Area Network WG: Wiegand 16 C315W User Manual Contact us For more information about the product, please visit us at www.akuvox.com or feel free to contact us by Sales email: sales@akuvox.com Technical support email: techsupport@akuvox.com Telephone: +86-592-2133061 ext.7694/8162 We highly appreciate your feedback about our products. 17