UHF RFID READER MODULE RM-100 USA Users Manual Key Features ISO 18000-6C(Gen2) protocol support Dynamic RF output power : -4dBm to +27dBm Low current to extend battery life Compact size Low cost Introduction and system composition diagram Introduction The RM-100EUROPE is an compact size RFID reader module developed for the embedded reader market, which comprises printers, industrial PDA , and similar devices. Target Application
- PDA type RFID Reader
- RFID PRINTER
- OEM Module
- Other application System composition diagram UART Tag #1 Tag #2 Tag #N 2 Composition parts Reader module Antenna Interface connector cable User manual 3 Module Description ANT port : connect rf cable to reader module and ANT. RF switch connector : TX, RX test port. USB_D-
TXD RXD VCC GND USB_D+
VCC : 4.0 V 1A 4 Operation method ----------(1) Nesslab RFID Mobile Reader Application v1.0 setting
- Program Setting 1. Connect serial data cable (RS-232 to UART) to PC and Reader. 2. Run Nesslab RFID Mobile Reader Application v1.0 with window XP 3. First, check Serial , ISO 1800-6C and COM1 . 4. Supply 4.0v to module. The buzzer is sounded BEEP 5 Operation method ----------(2) 4. Click connect . 6 Operation method ----------(3) 5. Cleck 6. If this screen is displaied, the program setting is complited 6 Operation method ----------(4)
- Program Setting 1. The channel setting operation 1) If the frequency hopping ON/OFF check box is checked, set the frequency hopping ON/OFF check box unchecked. 2) Write the channel number to the CH NUM box. 3) Click SET , then the channel setting is completed 4) If you click Multi Read the module read the tags at the channel which you check. 5) The tag data is displayed at the Result box. 6 Operation method ----------(4) 2. The normal operation 1) If the frequency hopping ON/OFF check box is unchecked, set the frequency hopping ON/OFF check box checked. 2) If you click Multi Read , the module read the tags. 3) The tag data is displayed at the Result box. 6 Channel Table CHANNEL NO FREQUENCY CHANNEL NO FREQUENCY CHANNEL NO FREQUENCY 41 42 43 44 45 46 47 48 49 50 918.2 MHz 918.4 MHz 918.6 MHz 918.8 MHz 919.0 MHz 919.2 MHz 919.4 MHz 919.6 MHz 919.8 MHz 920.0 MHz 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 910.2 MHz 910.4 MHz 910.6 MHz 910.8 MHz 911.0 MHz 911.2 MHz 911.4 MHz 911.6 MHz 911.8 MHz 912.0MHz 912.2 MHz 912.4 MHz 912.6 MHz 912.8 MHz 913.0 MHz 913.2 MHz 913.4 MHz 913.6MHz 913.8MHz 914.0 MHz 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 914.2 MHz 914.4 MHz 914.6 MHz 914.8 MHz 915.0 MHz 915.2 MHz 915.4 MHz 915.6 MHz 915.8 MHz 916.0 MHz 916.2 MHz 916.4 MHz 916.6 MHz 916.8 MHz 917.0 MHz 917.2 MHz 917.4 MHz 917.6MHz 917.8 MHz 918.0 MHz 6 Cautions
- Additional Page -
Modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. FCC compliance Information This device complies with part 15 of FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received. Including interference that may cause undesired operation. Information to User This equipment has been tested and found to comply with the limits for a Class B digital device, Pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio Frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help. FCC WARNING:
This equipment may generate or use radio frequency energy. Changes or modifications to this equipment may cause harmful interference unless the modifications are expressly approved in the instruction manual. The user could lose the authority to operate this equipment if an unauthorized change or modification is made. FCC RF EXPOSURE:
The EUT will only be used with a separation of 20 centimeters or greater between the antenna and the body of the user.