WARNING:pdfminer.pdfpage:The PDF <_io.BufferedReader name='/Volumes/Scratch/Incoming/eg-scratch/5480125.pdf'> contains a metadata field indicating that it should not allow text extraction. Ignoring this field and proceeding. Use the check_extractable if you want to raise an error in this case Quick Installation Guide Wireless AC1200 Wave 2 Industrial Outdoor Access Point DIS-3650AP Additional documentation is also available on the D-Link website Before You Begin System Requirements This installation guide provides instructions for installing the DIS-3650AP on your network. Additional documentation is also available on the D-Link support website. Nuclias Connect Manual: For additional information and instructions on how to configure the device using Nuclias Connect. DIS-3650AP User Manual: For additional information and instructions on how to configure the device using the web user interface. Package Contents This DIS-3650AP package includes the following items:
DIS-3650AP Access Point Quick Start Guide Mounting kit (Wall/Pole/DIN Rail Mount)
- Articulation Pole x 1
- T-form Bracket x 1
- M8x40 Screw Bolts x 1
- M6 Screw x 4
- M8 Nut x 1
- Washer (M8 x 1 ; M6 x 4)
- Spring Washer (M8 x 1 ; M6 x 4)
- Stainless Hose Clamp x 2
- Anchors plastic screws x 4
- Stainless screws x 4
- DIN Rail mounting kit If any of the above items are damaged or missing, please contact your local D-Link reseller. Note: To power the unit, use an 802.3at PoE Switch or PoE Injector. Computers with Windows, Macintosh, or Linux-based operating systems with an installed Ethernet Adapter Hardware Overview LED Indicators 1 2 3 4 Figure 1: Side Panel LED
1 2 3 4 LED Description Power/
Status Green (Solid) - Device operational Red (Flashing) - Device booting up/
Device malfunctioned Red (Solid) - Device boot up has failed 2.4 5G Solid green - 2.4GHz is enabled Blinking green - data transmission Solid green - 5GHz is enabled Blinking green - data transmission LAN
(PoE) Indicates whether a device is connected to LAN and receiving power on the PoE port. Table 1: LED Description DIS-3650AP Quick Installation Guide 1 ENGLISH Interface Connectors 1
# Connector DIN rail Adapter Wall/Pole Mount Grounding Wire 2 3 Description Connect DIN rail kit to mount it on DIN-Rail. Mount to connect to the mounting plate on a wall or a pole. Connector for the grounding wire. Table 3: Interface Description 1 2 3 Figure 2: Top Connectors Installation Using Power over Ethernet (PoE) 1. Use a standard Ethernet cable to connect the LAN(PoE) port on the DIS-3650AP to a PoE power source device such as an 802.3at PoE switch or PoE injector. Configuration Using Nuclias Connect The DIS-3650AP is designed to be managed through Nuclias Connect. Refer to the Nuclias Connect Manual for detailed configuration instructions. Note: D-Link recommends manually configuring the device before mounting it. Nuclias Connect App Configuration 1. Download the free Nuclias Connect app from the App Store or Google Play by searching for Nuclias Connect or by scanning the QR code below.
# Connector Description 1 LAN(PoE) 2 CONSOLE 3 Reset Gigabit RJ-45 port for data and Power over Ethernet (PoE) power. Connect an RJ-45 Ethernet console for CLI control (Option) Press and hold for 10 seconds to factory reset the device Table 2: Interface Description 1 2 3 Figure 3: Back Connectors 2 DIS-3650AP Quick Installation Guide ENGLISH 2. Open the Nuclias Connect app and follow the onscreen instructions to discover and set up your device. Connect an Ethernet Cable to the LAN(PoE) port on the DIS-3650AP. Use the LAN Port Waterproof Enclosures to seal the ports. Manual Configuration Note: The management computer, DHCP server and DIS-3650AP must be in the same subnet. Use one of the following methods to access the web user interface:
Connecting through Ethernet 1. Use an Ethernet cable to connect the DIS-3650AP to the switch or router the management computer is connected to. 2. Manage the access point from a computer. Enter dis3650ap.local in the address field of your browser. Log in to the administration user interface. The default login information is 3. Username: admin Password: admin Install Enclosure Onto The Articulation Pole Attach the articulation pole to back of AC using M5x16 screws & washers. Figure 5 Connecting Wirelessly Installation for Wall 1. Connect the management computer to the default SSID of the DIS-3650AP, dlink. 2. Manage the access point from a computer. Enter dis3650ap.local in the address field of your browser. Log in to the administration user interface. The default login information is 3. Fix the T-from Bracket to the wall by using the wood / gyprock screws. Username: admin Password: admin Mounting Figure 6 Figure 4: LAN Port Waterproof Enclosure DIS-3650AP Quick Installation Guide 3 ENGLISH Installation for Pole Mounting for Recommended Pole Dia.:
1.5~2(38.1~50.8mm) Mounting for Pole 1~ 3
(25.4~76.2mm) Fix the T-from Bracket to the pole by using the stainless hose clamp.
(A)
(B) Figure 8 Install Articulation Pole with The T-formed Bracket After finishing the previous two steps, fix the articulation pole to the T-formed bracket by using M8x40 bolts, nut, spring washer and washer. Figure 7
(A) The diameter of the Pole is too large Will result in the failure to install smoothly, the diameter is too small and the clamping force is insufficient.
* Pole diameter Max.: 2.1(53.3mm) Min.: 1.0(25.4mm)
(B) To minimize bolts crosstalk, the bolts should gradually increasing load and parallel tighten. Figure 9 4 DIS-3650AP Quick Installation Guide ENGLISH Installation for DIN Rail The DIS-3650AP can be mounted on a standard DIN rail using the included DIN mounting kit. Use the following instructions to install the DIS-
3650AP on a rail:
1. Install a Din rail kit on enclosure. Check that the DIN rail kit is installed properly using two screws on each end. Figure 12: Attaching the Grounding Wire 3. A grounding wire is to protect your device from lightning strikes and the buildup of static electricity. Attach the grounding wire to the DIS-3650AP using the included screw(M3.9 * 7.8 mm). Figure 10 2. Position the DIS-3650AP against the rail, then tilt it upwards and hook the DIN rail clip on the back of the device against the rail. Snap the device into place to complete the installation. Figure 13: Attaching the Grounding Wire Figure 11 DIS-3650AP Quick Installation Guide 5 ENGLISH 4. Tighten the grounding wire (green-and-
yellow, 18AWG) to the DIS-3650AP until it is securely attached. Professional installation instruction 1. Installation personal This product is designed for specific application and needs to be installed by a qualified personal who has RF and related rule knowledge. The general user shall not attempt to install or change the setting. 2. Installation location The product shall be installed at a location where the radiating antenna can be kept 28cm from nearby person in normal operation condition to meet regulatory RF exposure requirement. 3. External antenna Use only the antennas which have been approved by the applicant. The non-approved antenna(s) may produce unwanted spurious or excessive RF transmitting power which may lead to the violation of FCC limit and is prohibited. 4. Installation procedure Please refer to users manual for the detail. 5. Warning Please carefully select the installation position and make sure that the final output power does not exceed the limit set force in relevant rules. The violation of the rule could lead to serious federal penalty. Figure 14: Attaching the Grounding Wire 5. Attach the other end of the grounding wire to either the wall or pole mount. Ensure that the wall or pole mount is connected to an electrical ground. TECHNICAL SUPPORT dlink.com/support 6 DIS-3650AP Quick Installation Guide ENGLISH Appendix - Statements Federal Communication Commission Interference Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to pro-vide reasonable protection against harmful interference when the equipment is operate din a commercial environment. This equipment generates, uses, and can radiate radiofrequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. FCC Caution:
Any changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 28cm between the radiator & your body. Note: The country code selection is for non-US model only and is not available to all US model. Per FCC regulation, all WiFi product marketed in US must fixed to US operation channels only. Dclaration dexposition aux radiations Cet quipement est conforme aux limites dexposition aux rayonnements ISED tablies pour un environnement non contrl. Cet quipement doit tre install et utilis avec un minimum de 0.28 m de distance entre la source de rayonnement et votre corps. RED Compliance Statement Compliance with 2014/53/EU Radio Equipment Directive (RED) In accordance with Article 10.8(a) and 10.8(b) of the RED, the following table provides information on the frequency bands used and the maximum RF transmit power of the product for sale in the EU:
Frequency range (MHz) 2412-2472 5500-5700 Max. transmit power (dBm) 19.88 dBm 28.44 dBm DIS-3650AP Quick Installation Guide 7 ENGLISH This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body. Product and Warranty Information To find out more about D-Link Nuclias product or marketing information, please visit the website http://
www.dlink.com or https://www.nuclias.com. The D-Link Limited Lifetime Warranty information is available at http://www.dlink.com/warranty 1. Instructions for the installation of that conductor to building earth by a SKILLED PERSON. 2. Please contact the authorized distributor of D-Link for related accessories (Outdoor interconnection cable, Cable Gland, Cable, etc.) for purchase and installation. 8 DIS-3650AP Quick Installation Guide ENGLISH Notes Notes Notes Notes Ver. 1.00(WW)_130x183 2021/09/27 5300-00008121-01W