INTRODUCTION 1 1.1 LYNX DESCRIPTION The Lynx contains the most innovative technical features, providing them to the user in an ergonomic and elegant form factor. The accelerometer, the vibrator alert and the 3 LEDs help to do not waste time in the configuration and usage of the product. Working with the Lynx becomes an easy pleasure. The great aesthetics does not put the rubustness on a second level.The Lynx has been deisgned for surviving to industrial environmental, outside and inside the four walls. The reliability of the product continues with the architecture chosen: an 806MHz processor working with 256 MB RAM and 512 MB of Flash. A Micro SD card slot supporting SDHC storage cards provides for virtually unlimited storage space. The Lynx has been equipped with both a 1D laser scanner and 2D bar code imager. For being ready also to the most demanding applicatinons, an autofocus camera with flash has been foreseen on the back of the product. The Lynx provides four wireless technologies in the same form factor, without antenna protruding: Bluetooth v2.1 EDR for fast data transfer, 802.11b/g/n with CCX v4, 802.11i Security, UMTS HSPA+ for real-time communication outside the four walls and Assisted GPS (A-GPS) with Skyhooks Core Engine hybrid positioning system for location based applications. Them micro-USB port facilitates charging with a phone industry standard power supply or On-the-Go (OTG) communications. The Lynx integrates the latest Windows Embedded Hend Held 6.5, tailored for mobile devices. As all the Datalogic ADC Computers, also this PDA is offering Wavelink Avalanche for a fast configuration and deploymant. Finally, Datalogics comprehensive service programs protect the Lynx investment. communication options: 802.11 b/g/n radio, Bluetooth, GSM data capture options: laser, 2D imager compute options: Windows Mobile 6.5 keyboard options: numeric, qwerty 1.2 AVAILABLE MODELS The brand new Lynx is available in different models depending on the options it is equipped with. All options are listed below:
For further details about the Lynx models refer to the web site:
www.adc.datalogic.com. For further information regarding Windows Embedded Handheld refer to the website:
http://www.microsoft.com/windowsembedded. The currently available models are:
944400000 Lynx with Bluetooth v2.0, Wi-Fi 802.11 b/g/n, Decodified Laser (SE955), Windows Mobile 6.5, 27-Key Numeric Lynx 00N0LD-1N0-MEN0 944400001 Lynx with Bluetooth v2.0, UMTS HSPA+ Voice and Data, Assisted GPS, Wi-Fi 802.11 b/g/n, Decodified Laser (SE955), Camera, Windows Mobile 6.5, 27-Key Numeric Lynx H2N0LD-1N1-MEN0 Lynx 00N0WI-1N1-MEN0 944400002 Lynx with Bluetooth v2.0, Wi-Fi 802.11 b/g/n, 2D Imager (4500) Wide Aspect, Camera, Windows Mobile 6.5, 27-Key Numeric 944400003 Lynx with Bluetooth v2.0, UMTS HSPA+ Voice and Data, Assisted GPS, Wi-Fi 802.11 b/g/n, 2D Imager (4500) Wide Aspect, Camera, Windows Mobile 6.5, 27-
Key Numeric Lynx H2N0WI-1N1-MEN0 Lynx 00N0LD-1Q0-MEN0 944400004 Lynx with Bluetooth v2.0, Wi-Fi 802.11 b/g/n, Decodified Laser (SE955), Windows Mobile 6.5, 46-Key QWERTY 944400005 Lynx H2N0LD-1Q1-MEN0 Lynx with Bluetooth v2.0, UMTS HSPA+ Voice and Data, Assisted GPS, Wi-Fi 802.11 b/g/n, Decodified Laser (SE955), Camera, Windows Mobile 6.5, 46-Key QWERTY Lynx 00N0WI-1Q1-MEN0 944400006 Lynx with Bluetooth v2.0, Wi-Fi 802.11 b/g/n, 2D Imager (4500) Wide Aspect, Camera, Windows Mobile 6.5, 46-Key QWERTY 944400007 Lynx with Bluetooth v2.0, UMTS HSPA+ Voice and Data, Assisted GPS, Wi-Fi 802.11 b/g/n, 2D Imager (4500) Wide Aspect, Camera, Windows Mobile 6.5, 46-
Key QWERTY Lynx H2N0WI-1Q1-MEN0 1.3 PACKAGE CONTENTS The Lynx package contains:
1 Lynx PDA 1 Lynx quick start guide 1 rechargeable battery pack (standard for Wi-Fi models, high cap for UMTS models) 1 power supply with regional plugs 1 Lanyard 1 guitar pick stylus Any other packages will contain the accessories necessary for the Lynx connection to the host computer and to the network: the cradle, one or more connection cables. Remove all the components from their packaging; check their integrity and congruity with the packing documents. Keep the original packaging for use when sending products to the technical assistance center. Damage caused by improper packaging is not covered under the warranty. CAUTION Rechargeable battery packs are not initially charged. Therefore the first operation to perform is to charge them. See paragraph !
.. NOTE INSERTING MICROSD CARD 1.4 Lynx supports microSD memory cards. To access the microSD card slot and insert the card, proceed as follows:
1. Turn off the Lynx. 2. Shift the battery latch to the left and remove the battery pack:
3. Open the card slot and insert the microSD card with the written part downward:
4. Shift the card to the right to lock it into the cardholder; close the card slot:
5. First insert the bottom (contacts) and then the upper side of the battery pack into the slot. Press until the battery latch clicks.. 1.4.1 Removing the MicroSD Card To remove the microSD card, follow the steps above to access the microSD card cage under the battery, and remove it from microSD slot. the to avoid damaging Follow proper ESD precautions microprocessors in the Lynx or the microSD card itself. Proper ESD precautions include, but are not limited to, working on an ESD mat and ensuring that the operator is properly grounded. Do not force the card. If you feel resistance, remove the card, check the orientation, and reinsert it. Do not use the microSD card slot for any other accessories. It is highly recommended that users latch the card cage's bale even when the card is not present. CAUTION INSTALLING THE SIM CARD 1.5 To correctly insert the SIM Card, proceed as follows:
1. Turn off the Lynx. 2. Shift the battery latch to the left and remove the battery pack:
Insert the SIM card with the contacts downwards:
3. 4. First insert the bottom (contacts) and then the upper side of the battery pack into the slot. Press until the battery latch clicks. CAUTION Follow proper ESD precautions to avoid damaging the SIM card. Proper ESD precautions include, but are not limited to, working on an ESD mat and ensuring that the operator is properly grounded. Do not force the card. If you feel resistance, remove the card, check the orientation, and reinsert it. Do not use the SIM card slot for any other accessories. 1.5.1 Removing the SIM Card To remove the SIM card, follow the steps above to access the SIM area, and remove it from its slot. NOTE All the basic functionalities normally associated to the SIM card are managed by the terminal (GPRS connectivity, phone calls, SMS handling). All core functionalities (GPRS connectivity, phone calls, and SMS handling) is managed by the terminal. Advanced functionality may require additional software from the SIM card vendor. It is possible that not all the services connected to the SIM card can be used or can be managed by the terminal. 1.6 ACCESSORIES Cradles 94A150036 Dock, Single Slot, Lynx 94A150037 Charger, 4 Slot Dock, Lynx 94A150038 Dock, Ethernet 4 Slot, Lynx 94A150039 Charger, 4 Slot Battery, Lynx Batteries 94ACC0064 Battery, Standard Capacity, Lynx 94ACC0065 Battery, High Capacity, Lynx Power Supply 94A051975 Power Adapter, 12 to 24v Pwr Plug 2.1mm 94A051976 Adapter, Pwr Jack 2.1mm To Handylink 94ACC1380 Power Supply, Micro USB 94ACC1381 Power Supply, Dock, PWR Plug 2.1mm Cables 94A051020 Cable for dock-PC (RS232) communication 94A051968 Cable, Micro USB, Client 94A051969 Cable, Micro USB, Host 94A051970 Cable, USB Handylink, Client 94A051971 Cable, USB Handylink, Host 94A051972 Cable, RS232 Handylink, Client 94A051973 Cable, RS232 Handylink, Host 94A051974 Cable, Dex Handylink Various 95ACC1033 Screen Protector Kit, 5 Pack 94ACC1230 Swivel for Functional Case (10pcs) 94ACC1345 Stylus Pen (10 pcs.) 94ACC1371 Module, Ethernet, Single Slot Dock 94ACC1372 Module, Modem, Single Slot Dock 94ACC1382 Stylus, Guitar Pick W/ Cord (5pcs) Use only a Datalogic ADC-approved power supply and cables. Use of an alternative power supply will invalidate any approval given to this device and may be dangerous. NOTE 2. BATTERIES AND MAINTENANCE NOTE CAUTION Rechargeable backup batteries and battery packs are not initially charged. Therefore the initial operation to perform is to charge them. See below. By default, the battery pack is disconnected at the factory to avoid damage due to excessive draining. Annual replacement of rechargeable battery pack avoids possible risks or abnormalities and ensures maximum performance. 1.1 CHARGING THE BATTERY PACK The battery pack autonomy varies according to many factors, such as the frequency of barcode scanning, RF usage, battery life, storage, environmental conditions, etc. NOTE The battery icon on the Taskbar indicates when the battery pack is low. It is possible to recharge the battery pack by connecting the power supply directly to the Lynx. Alternatively, it is also possible to recharge the battery pack by using the single slot dock, the powered mobile dock, the Ethernet four slot dock or the four slot battery charger. Moreover recharging is possible by USB Direct connection with the host computer, but with longer charging times and only if the PDA is off. During the charging process the LED positioned at the left side of the display is red constant. Once the charging process has been completed this LED is green constant
(see par. ! .). If the battery pack is removed from the PDA, it can be recharged by inserting it into the rear slot of the single slot dock, the powered mobile dock, the Ethernet four slot dock or the four slot battery charger. NOTE CAUTION CAUTION Its recommended to charge batteries before first use. Risk of explosion if battery is replaced by an incorrective type. Dispose of used batteries according to the instructions. Il y a risque dexplosion si la batterie est remplace par une batterie de type incorrect. Mettre au rebut les batteris usages conformment aux instructions. Avoid storing batteries for long periods in a state of full charge or very low charge. We recommend charging the battery pack every two to three months to keep its charge at a moderate level to maximize battery life. CAUTION Even if the storage temperature range is wider, In order to achieve the longest battery life, store the terminal and the spare batteries between 20 to 30 C (68 to 86 F). Extended batteries must be charged at a temperature ranging from 0 to +45C (+32 to +113F). Standard batteries must be charged at a temperature ranging from 0 to +45C (+32 to +113F). The battery level may display incorrectly for several minutes after the Lynx is disconnected from its charger if the charging cycle is not completed. NOTE NOTE NOTE NOTE The Lynx could get warm during charging, this is normal and does not mean a malfunction. Use only a USB-IF compliant USB port as a charging source. 1.2 REPLACING THE BATTERY PACK To correctly replace the battery pack, proceed as follows. 1. Turn off the Lynx. 2. Shift the battery latch to the left and remove the battery pack:
3. Install the new battery pack, first insert the bottom (contacts) and then the upper side of the battery pack into the slot. Press until the battery latch clicks. WARNING Installing, charging and/or any other action should be done by authorized personnel and following this manual. The battery pack may get hot, explode, ignite, and/or cause serious injury if exposed to abusive conditions. If the battery pack is replaced with an improper type, there is risk of explosion. Do not place the battery pack in or near a fire or heat; do not place the battery pack in direct sunlight, or use or store the battery pack inside unventilated areas in hot weather; do not place the battery pack in microwave ovens, dryer, high pressure containers, on induction cookware or similar device. Doing so may cause the battery pack to generate heat, explode or ignite. Using the battery pack in this manner may also result in a loss of performance and a shortened life expectancy. Use only a Datalogic ADC approved power supply. The use of an alternative power supply will void the product warranty, may cause product damage and may cause heat, explode or ignite. The area in which the units are charged should be clear of debris and combustible materials or chemicals. Do not use the battery pack of this terminal for power devices different from this PDA. Immediately discontinue use of the battery pack if, while using, charging or storing the battery pack, the battery pack emits an unusual smell, feels hot, changes colour or shape, or appears abnormal in any other way. Do not short-circuit the battery pack contacts connecting the positive terminal and negative terminal. This might happen, for example, when you carry a spare battery pack in your pocket or purse;
accidental shortcircuiting can occur when a metallic object such as a coin, clip, or pen causes direct connection of the contacts of the battery pack (these look like metal strips on the battery pack). Short circuiting the terminals may damage the battery pack or the connecting object. Do not apply voltages to the battery pack contacts. Do not pierce the battery pack with nails, strike it with a hammer, step on it or otherwise subject it to strong impacts or shocks. Do not disassemble or modify (i.e. bend, crush or deform) the battery pack. The battery pack contains safety and protection devices, which, if damaged, may cause the battery pack to generate heat, explode or ignite. In case of leakage of liquid from the battery, avoid contact with liquid the skin or eyes. If the contact occurs, immediately wash the affected area with water and consult a doctor. Do not solder directly onto the battery pack. Do not expose the battery pack to liquids. Avoid any knocks or excessive vibrations. If the device or the battery is dropped, especially on a hard surface, you should take it to the nearest Authorised Repair Centre for inspection before continuing to use it. Do not replace the battery pack when the device is turned on. Do not remove or damage the battery packs label. Do not use the battery pack if it is damaged in any part. Battery pack usage by children should be supervised. Collect and recycle waste batteries separately from the device in comply with European Directive 2006/66/EC, 2002/95/EC, 2002/96/EC and subsequent modifications, US and China regulatory and others laws and regulations about environment. In order to guarantee an adequate operating autonomy, when replacing the battery pack the PDA checks the battery energy level. If the battery is not sufficiently charged, Lynx does not turn on (when pressing the ON/OFF key). In this case, either substitute the battery pack with a charged one
(sufficiently charged) or insert Lynx into a powered cradle or plug it into the direct power supply. To maximize battery life, turn off radios when they are not needed. WARNING NOTE NOTE CLEANING THE PDA 1.3 Periodically clean the Lynx with a slightly dampened cloth. Do not use alcohol, corrosive products or solvents. 3. CONNECTIONS 1.1 USB CONNECTION You can use the standard micro USB cable 94A051968 or the Datalogic Handylink cable 94A051970 to directly connect the Lynx to a host computer to transfer data through the USB interface. A B C Key:
A Host computer B Standard Micro USB cable 94A051968/ 94A051970 Handylink USB Client Cable C Lynx Connection through the cable complies to the 1.1 USB standard. NOTE The Single Dock can be connected to the Host by means of the Micro-B USB cord 94A051968. Once the host has been turned on, insert the Lynx PDA into the cradle. A B C D Key:
A Host computer B 94A051968 Micro USB Client Cable C 94A150036 Lynx Single Slot Dock D 94ACC1381 Power Adapter NOTE NOTE Connection through the cradle complies to 1.1 USB standard. The actual data transfer speed can be appreciably lower than the maximum theoretical speed. 1.2 CONNECTION TO USB PERIPHERALS To connect the Lynx to a keyboard or a memory, connect the terminal to the Datalogic 94A051969 cable or to the Datalogic 94A051971 cable (together with a standard A to micro A USB cable). For all these devices maximum current withdrawal must be below 100mA. B A Key:
A Keyboard with USB interface B Lynx A Key:
A USB hard drive/ external memory source B Lynx D C C 94A051969 Micro USB Host Cable/
94A051971 Handylink Micro USB Host Cable D Standard A to Micro A USB Cable D C B C 94A051969 Micro USB Host Cable/
94A051971 Handylink Micro USB Host Cable D Standard A to Micro A USB Cable Connect the Single Slot Dock to the peripheral by means of a Micro-A USB cord, or use a Micro-A to Std-A receptacle USB adapter such as Datalogic 94A051969
(together with a standard USB cable if needed). B A D C E A USB Peripheral (memory) B Lynx Single Slot Dock C 94A051969 Micro USB Host Cable D Standard A to Micro A USB Cable E 94ACC1381 Power Adapter Lynx works with most of mentioned USB peripherals. Datalogic can not guarantee the operations of Lynx with all devices on the market. Connection is compliant to 1.1 USB standard. The actual data transfer speed can be appreciably lower than the maximum theoretical speed. NOTE NOTE NOTE 1.3 RS232 CONNECTION You can use the Datalogic 94A051972 cable to directly connect the Lynx to a host computer to transfer data through the RS232 interface A B C Key:
A Host computer B 94A051972 Handylink Micro RS232 Client Cable C Lynx The Single Slot Dock can be connected to the Host by means of a standard null modem cable such as Datalogic 94A051020 CAB-427 for 9-pin connections. Once the Host has been turned on, insert the Lynx PDA into the cradle. A C B D Key:
A Host Computer B 94A051020 CAB-427 RS232 Null Modem Cable C Lynx Single Slot Dock D 94ACC1381 Power Adapter 1.4 WLAN CONNECTION Lynx 802.11 b/g/n radio models can communicate with the host using the on-board radio frequency component and an Access Point connected to the host computer. For models using the 802.11 b/g/n radio, you can find information about the applet for radio configuration: http://www.summitdata.com/SCU.htm. To launch this utility you can tap the specific icon if it's visible on the taskbar or you can select the menu item: Start->Programs->Summit and tap the SCU icon. A B A C Key:
A) Lynx B) Access point C) Host Application Server NOTE NOTE NOTE NOTE 802.11 b/g/n radio module is on by default, in order to avoid wasting energy, you can switch it off using the SCU. Suspending the terminal powers off the 802.11 b/g/n radio and drops the radio connection. When the terminal resumes, depending on the radio power mode and security protocol selected, it may take up to 30 seconds for the 802.11 b/g/n radio driver to re-associate the radio to the network. Area coverage and to environmental conditions, access points types or interference caused by other devices (microwave ovens, radio transmitters, etc.). radio performance may vary, due In case of heavy usage the Lynx could get warm, this is normal and does not mean a malfunction. 1.5 WPAN CONNECTIONS Lynx Bluetooth, models can communicate with a Bluetooth, device, such as a printer, within a range of 10 m, using the on-board Bluetooth, module. B A Key:
A) Lynx B) Bluetooth, printer In order to extend battery life, the Bluetooth, module is off by default. If you need to have Bluetooth working, the module must be powered on using the Wireless Communications applet (see par.
! .), and perform the Discovery procedure (see par. ! .). Suspending the terminal powers off the Bluetooth radio and drops the piconet (Bluetooth connection). When the terminal resumes, it takes approximately 10 seconds for the Bluetooth radio driver to re-
initialize the radio. Area coverage and Bluetooth radio performance may vary, due to environmental conditions or interference caused by other devices
(microwave ovens, radio transmitters, etc.). NOTE NOTE NOTE 1.6 WWAN CONNECTION Lynx GSM models enhance your connectivity solutions giving you an opening to an international wireless infrastructure that is the global standard. GSM (Global System for Mobile communications) is a digital mobile phone system based on TDMA; it utilizes the 850, 900, 1800 and 1900 MHz bands. MicroPDA,comeElf,ancheUMTS/HSDPA. Bande:UMTS/HSPA+:800/850/900/1900/2100MHz GSM/GPRS/EDGE85090018001900MHzforvoiceanddata communication. In order to use a WWAN Connection you have to install a SIM Card (see instructions on par. 1.5). NOTE NOTE In order to avoid wasting energy, the GSM module is off by default. If you need to have GSM working, the module must be powered on using the Wireless Communications applet (see par. !
.). Suspending the terminal powers off the GSM radio and drops the connection. When the terminal resumes, if the connection was managed by Microsoft Internet Explorer, it is automatically restored, otherwise, the radio connection must be manually re-initialized. the SIM Card option is not available in 802.11 a/b/g radio and batch models The GSM voice capability of this PDA has to be addressed to occasional use, in well covered areas. If the coverage is poor, the voice quality can be highly affected. NOTE NOTE NOTE NOTE Calls can be made or received using the Lynx as a phone handset, by the Lynx headset or by a Bluetooth headset. During a call, you can set the speaker volume by pressing the arrow navigation keys. In case of heavy usage the Lynx could get warm, this is normal and does not mean a malfunction. 1.7 WIRELESS AND RADIO FREQUENCIES WARNINGS Use only the supplied or an approved replacement antenna. Unauthorized antennas, modifications or attachments could damage the product and may violate laws and regulations. WARNING WARNING WARNING Most modern electronic equipment is shielded from RF signals. However, certain electronic equipment may not be shielded against the RF signals generated by Lynx. Datalogic recommends persons with pacemakers or other medical devices to follow the same recommendations provided by Health Industry Manufacturers Associations for mobile phones. Persons with pacemakers:
Should ALWAYS keep this device more than twenty five (25) cm from their pacemaker and/or any other medical device;
Should not carry this device in a breast pocket;
Should keep the device at the opposite side of the pacemaker and/or any other medical device;
Should turn this device OFF or move it immediately AWAY if there is any reason to suspect that interference is taking place. Should ALWAYS read pacemaker or any other medical device guides or should consult the manufacturer of the medical device to determine if it is adequately shielded from external RF energy. In case of doubt concerning the use of wireless devices with an implanted medical device, contact your doctor. Turn this device OFF in health care facilities when any regulations posted in these areas instruct you to do so. Hospitals or health care facilities may use equipment that could be sensitive to external RF energy. WARNING WARNING WARNING WARNING RF signals may affect improperly installed or inadequately shielded electronic systems in motor vehicles. Check with the manufacturer or its representative regarding your vehicle. You should also consult the manufacturer of any equipment that has been added to your vehicle. An air bag inflates with great force. DO NOT place objects, including either installed or portable wireless equipment, in the area over the air bag or in the air bag deployment area. If vehicles wireless equipment is improperly installed and the air bag inflates, serious injury could result. Turn off the device when in any area with a potentially explosive atmosphere. Observe restrictions and follow closely any laws, regulations, warnings and best practices on the use of radio equipment near fuel storage areas or distribution fuel areas, chemical plants or where some operation involves use of explosive materials. Do not store or carry flammable liquids, explosive gases or materials with the device or its parts or accessories. Areas with a potentially explosive atmosphere are often, but not always, clearly marked or showed. Sparks in such areas could cause an explosion or fire, resulting in injury or even death. 4. USE AND FUNCTIONING The use of the Lynx depends on the application software loaded. However there are several parameters that can be set and utilities that can be used to perform some basic functions such as data capture, communications, file management, etc 1.1 STARTUP The Lynx turns on when the battery pack or the external supply is inserted and the ON/OFF Power button is pressed. After the battery pack is installed, use the [ON/OFF] key to turn the PDA on and off. As soon as the PDA is on, the Windows Embedded Handheld 6.5 desktop configuration will appear on the screen. Wait a few seconds before starting any activity so that the PDA completes its startup procedure. Today Screen Start Menu Use the stylus (par. 1.1.1) as suggested to select icons and options. The PDA goes into power-off (low power with display and keyboard backlight off), when it is no longer used for more than a programmable timeout, which is defined in the POWER applet of the Control Panel. In this mode it can be awakened (resuming operation) by the [ON/OFF] key. NOTE The PDA can also be awakened or turned off by the application program. 1.1.1 Using the Stylus The stylus selects items and enters information. The stylus functions like a mouse. Tap:
Drag:
Tap-and-hold:
Touch the screen once with the stylus to open items and select options. Hold the stylus on the screen and drag across the screen to select text and images. Drag in a list to select multiple items. Tap and hold the stylus on an item to see a list of actions available for that item. On the pop-up menu that appears, tap the action you want to perform. To recalibrate the touch screen use the Stylus Applet (see par. 1.6.7). Use only original Datalogic styluses supplied with the product itself. In harsh applications, use of screen protectors should be taken into consideration, in order to extend the touch screen operating life. To prevent damage to the screen, do not use sharp devices or any device other than the Datalogic ADC -provided stylus. Do not apply too much pressure when touching the screen. For applications where an intensive use of the touch screen is foreseen, please consider that touch screen components are subject to progressive wear. CAUTION 1.2 WINDOWS EMBEDDED HANDHELD WELCOME WIZARD In Windows Embedded Handheld, at the very first Lynx startup, following a clean boot or following a registry restore to default values, the PDA startup (see par. 1.1) is preceded by the Welcome Wizard. Welcome Wizard Screen The Welcome Wizard allows the user to calibrate the touch screen (see par. 1.6.7) and to configure an email account and a password to protect the terminal. Touch Screen Calibration Screen 1.3 DATA CAPTURE To capture data first of all tap Start > Settings > System > Decoding:
To configure and enable data capture parameters refer to par. 1.6.1. Laser Data Capture 1.3.1 To scan barcodes, point the Lynx laser model onto the code from a distance within the reading range while pressing the SCAN key. The lighted band emitted by the laser must completely cross the barcode as shown in the figure below. If the scan has taken place correctly:
the Good Read LED gets constant Green for a configurable time;
if enabled, the GoodReadSound emits an acoustic signal;
if enabled, the GreenSpot projects a green spot onto the bar code image. Remove the protective film cover over the Laser Output Window before use. NOTE Imager Data Capture 1.3.2 The Lynx Imager captures a picture of the entire bar code. The omni-directional scanning does not require that the operator orient the bar code to align with the scan pattern. To read a 1D or 2D code, simply point the Lynx Imager model onto the code and press the SCAN Key. The Lynx Imager uses an intelligent aiming system pattern, similar to those on cameras, indicating the field of view, which should be positioned over the code:
Aiming System If the aiming system pattern is centered over the entire symbology as shown in the following figure, either wait for the timeout or release the Scan key to capture the image. A red beam illuminates the code, which is captured and decoded. You will get a good read. Linear barcode 2D Matrix symbol BX3 Relative Size and Location of Aiming System Pattern The field of view changes its size as you move the reader closer or farther away from the code. The field of view indicated by the aiming system pattern will be smaller when the Lynx Imager is closer to the code and larger when it is farther from the code. Symbologies with smaller bars or elements (mil size) should be read closer to the unit. Symbologies with larger bars or elements (mil size) should be read farther from the unit. (See par. ! . for further details). If the scan has taken place correctly:
the Good Read LED gets constant Green for a configurable time;
if enabled, the GoodReadSound emits an acoustic signal. 1.4 DESCRIPTION OF THE KEYS The Lynx comes with two different keyboards, an alphanumeric keyboard (qwerty), having 46 keys, and a numeric keyboard, having a total of 27 keys. 1.4.1 Alphanumeric Keyboard Numeric Keyboard Main Keys Function KEY FUNCTION It starts barcode data capture. They let you move forwards, backwards, upwards or downwards within text fields, scroll through a Menu list or browse among folder files. Yellow modifier (toggle key): when pressed before a standard key, it enables the character or function printed in yellow above the key. Blue modifier (one shot key): when pressed before a standard key, it enables the character or function printed in blue above the key It powers the Lynx ON or OFF. It is placed on the upper left side of the terminal. The hang up key normally generates the VK_TEND virtual key code, used to hang-up phone calls.and to exit applications. the hang up key generates a In blue mode, VK_ESCAPE virtual key code for applications that uses this specific virtual key code to exit (e.g. touch screen calibration application). Resetting the Lynx 1.4.2 There are several reset methods for the Lynx. A warm boot terminates an unresponsive application and clears the working RAM, but preserves the file system. Registry is restored from persistent memory if available or returned to factory default. A cold boot forces all applications to close reinitializing completely the system. It clears the working RAM, but the file system is preserved. Registry is restored from persistent memory. A clean boot restores the Lynx to a clean configuration: both the registry and the file system returns to a clean status that conforms to factory default. Warm Boot To perform a warm boot, press and hold the following keys simultaneously:
Cold Boot To perform a cold boot, do the following steps:
1. 2. 3. 4. 5. Turn off the Lynx by pressing the on-off key. Pull the battery latch down and remove the battery pack. Press the reset button. Insert the battery pack. Turn on the Lynx by pressing the on-off key. Clean Boot To perform a clean boot, do the following steps:
1. Perform a Cold Boot (see Cold Boot) 2. Press and hold down the 0 and hang up keys simultaneously and then press the on-off key:
A dialog box will appear asking for confirmation. Press the Enter Key. Registry Warm Boot Restored from flash Preserved Cold Boot Restored from flash Preserved Clean Boot Clean configuration (no user config) Clean Installation (no user files) File System 1.5 STATUS INDICATORS 1.5.1 The Lynx provides three different LEDs signaling the PDA status. LED Status LED STATUS Good Read
(right side) Charging Status
(left side) Red Green Green Red Scanning LED is ON from the time the user hits the scan button (Trigger) until the bar code is decoded (laser models) Time-out (imager models). Scanning LED is ON, showing a good decode. It is constant once the charging process has been completed (full charge). It is constant while charging. Red blinking In case of charge fault it is constant for two hours, then it starts blinking. Keyboard Status
(center) Off Keyboard in primary. Yellow solid Blue solid Yellow alternate key mode. Blue alternate key mode Pink CapsLock enabled. Taskbar 1.5.2 The Taskbar provides information about the time, the battery level, the keyboard function, and the decoding status. Windows Embedded Handheld Taskbar ICONS DESCRIPTION Zooms the screen. Opens the Wireless Manager (see par. 1.6.6). Displays the system battery status. Allows to set the volume of screen taps. Opens Clock & Alarms application. It allows to set date, time and alarms. 1.6 CONTROL PANEL From the Start menu, tap Settings. The Control Panel is split into three sections:
Personal, System, Connections. Control panel applets are displayed as icons; each icon corresponds to one applet:
Windows Embedded Handheld Control Panel 1.6.1 Data Capture Configuration You can configure the Lynxs decoding options by tapping Start -> Settings ->
System -> Decoding:
There are two sections in the Decoding control panel, each containing additional pages. There are seven General Configuration pages and multiple Barcode symbology pages. DECODING CONFIGURATION PAGES Select the desired configuration from the options shown in the figure below, and the other Decoding Properties figures on the following pages. Select General or 1D Bar Code, then use the menu or tap the left and right arrow keys to navigate the different pages of the Decoding utility. The menu options will change to reflect the items most recently selected. Audio From the Decoding menu, tap Configure > General > Audio. Use it to set volume, tone, duration, and number of various types of beeps. Good Read From the Decoding Properties page, tap Configure > General > Good Read. Use it to enable Good Read indications, the use of Green Spot and a to set the decoding timeout for decoding labels. Formatting From the Decoding Properties page, tap Configure > General > Formatting. Use it to configure prefix, suffix and data separator character strings. General Options From the Decoding menu, tap Configure > General > General Options. Select from Label Programming Enable, Symbology IDs and Group Separator Replacement. Decoding Options From the Decoding Properties page, tap Configure > General > Decoding Options. Use it to configure the User ID for symbologies, Redundancy and Aggressive Decoding (if supported by the decoding module). Select a symbology to view or change the available properties settings. Spot Beam From the Decoding Properties page, tap Configure > General > Spot Beam. It allows enabling and configuration of Spot Beam and triggering modes. It is only available on devices equipped with laser and advanced long range laser decoding modules that support the Spot Beam Feature. Imager Options From the Decoding Properties page, tap Configure > General > Imager Options. It configures illumination, target beam and Pick List mode, and triggering modes. It is only available on devices equipped with 2D decoding engines. Devices From the Decoding Properties page, tap Configure > General > Devices. Use it to enable or disable the keyboard wedge for Barcode scanner. 1D Barcode Symbology Pages Use the drop-down menus from Configure > 1D Barcode, or tap the left and right arrow keys to navigate the different pages of the barcode symbology pages. Each barcode symbology opens to its own page, as shown in the figure below. Refer to the sample symbology control panels for examples of the types of fields and options you can modify. Codabar: Select Enable, Min/Max Lengths, Enable Checksum, Send Checksum, Send Start/Stop, Convert to CLSI and Wide Gaps. restore previous to from the Decoding Properties Settings menu Decoding Settings Select configurations and/or other available default settings. Choose from:
Factory Defaults Minimum Settings Maximum Settings Save (New Settings) Revert to Saved Settings The settings are saved when you tap OK. The settings are saved when you tap Yes. When open, Decoding Properties acts as a simple barcode test tool that provides the Data decoded and the Data Type of the barcode scanned. 1.6.2 Buttons From the Start menu, tap Settings > Personal > Buttons. On the Program Buttons tab, customize the program hardware buttons to launch your most used applications. Under Select a button, tap the button you want to assign a program to, and then select a program from Assign a program. To configure the way the up/down control repeats, use the Up/Down Control applet
(Start > Settings > Personal > Buttons > Up/Down Control). 1.6.3 DL Buttons In Windows Embedded Handheld devices, <F1>-<F10> buttons (excluding F5) are assigned by Windows to default applications. To customize one of these buttons and assign it to a different application, you first need to disable it. Tap Start > Settings > System > DL Buttons to display the DL Buttons window:
Select the button you want to disable. Select the function None and the click OK. To remove the disabled button, select it and click Delete. A dialogue box appears, asking for confirmation. Click Yes:
To add the button back, click New and write the name of the button on the box that appears:
To assign a new application to the button, select the function and then click OK:
To restore the old settings , do a clean boot. Triggers 1.6.4 Triggers are special customizable buttons that are mapped by default by DL Mobile. Also, they can be set as wakeup buttons:
TRIGGER Scan Pistol Trigger APPLICATION Bar Code Bar Code 1.6.5 Application Switcher The application switcher provides the same functionality as the standard Windows Alt+Tab function. This allows the user to switch between the various open applications. The application switcher is activated via an assigned shortcut key specified in the DL Buttons tab (refer to par. 1.6.3). When the assigned button is pressed, the dialog shown below will be displayed:
The <Esc> key can be used to close the Application Switcher. NOTE Press the assigned button to open the application switcher. Press the assigned button to cycle through the running applications when the dialog is open. Press
<Enter> to switch to the selected application or <Esc> to close the application switcher. 1.6.6 Wireless Communications The Wireless Manager application is a sort of 'Control Panel' for wireless connections. From here it's possible to turn on or off bluetooth and radio modules. Open the Wireless Manager by tapping Start > Settings > Connections > Wireless Manager, or by tapping the connectivity icon on the taskbar (see par. !
.). The following window will appear:
Summit Client Utility (SCU) Wireless networking has a customized control, Summit Client Utility (SCU), specific to the radio. From the Start menu, tap: Summit > SCU:
The SCU will open to the Main tab:
Summit Client Utility 1. To create a new profile, tap the "Profile" tab:
Information about the wireless network can be entered directly in the profile tab or by pressing Scan when the desired network ESSID is in range. 2. At the "Scan" screen, select the desired SSID:
3. Click the "Configure" button 4. Follow the on-screen instructions to setup security parameters for your network. For more detailed settings specific to your installation please contact your wireless network administrator. 5. When finished, click Commit to save your settings. Return to the Main tab, if you have not previously selected Commit you will be prompted to save your changes. At the Main tab select the profile you just created. If you used the scan button the desired profile will have the same name as the ESSID. Use the Status tab to check connectivity to the network. More detailed information about the applet for radio configuration can be found at http://www.summitdata.com/SCU.htm. Stylus Calibration 1.6.7 You might need to recalibrate the touch screen (i.e. when you attempt to select one item with the stylus, another item is erroneously selected). To recalibrate the touch screen, complete the following steps:
1. Select Start > Settings > System > Screen to open the Screen Settings dialog as shown in the figure below:
2. Tap Align Screen to open the Calibration screen shown in the figure below. 3. Carefully press and briefly hold stylus on the center of the target. Repeat as the target moves around the screen. 4. By completing the calibration procedure you implicitly accept the new calibration settings. 5. New calibration settings are persistently saved in registry. Startup Stylus Calibration When starting the terminal, a Welcome Wizard (with Stylus Calibration) comes up if valid calibration settings are not available. This happens following circumstances:
1. At the first startup of the terminal. 2. After any cold boot if the user skipped stylus calibration earlier. 3. After a Clean Boot. the in 1.6.8 Audio Settings There are two applets that control volume: Audio and Volume & Sounds. Audio From the Start Menu, tap Settings > System > Audio:
The audio control panel can be used to independently set the playback or recording volume for different types of audio inputs and outputs, such as a headset, powered mobile dock, or the internal speakers and microphone. Audio Windows Sounds & Notifications From the Start Menu, tap Settings > Sounds and Notifications:
The Volume & Sounds applet configures audio features of all speakers and headphones:
Sounds Tab Notifications Tab To set the Bluetooth headset volume, you can also tap:
Start > Settings > System > Bluetooth Manager > Connections and select the headset. The following window will appear:
1.7 WINDOWS CONNECTIONS To connect the Lynx to another device (i.e. Host PC) from Windows, several programs are available. These programs require specific electrical connections in order to function properly. 1.7.1 Windows Mobile Device Center The desktop application Windows Mobile Device Center gives you the ability to synchronize information between a desktop computer and your Lynx. Synchronization compares the data on the Lynx with that on the desktop computer and updates both with the most recent information. Windows Mobile Device Center is only compatible with Windows Vista and Windows 7; if you run Windows XP or earlier, you have to download Microsoft ActiveSync. You can establish a connection to your Lynx through the following interfaces:
To establish a partnership between the Lynx and a host PC, start Windows Mobile Device Center and follow the steps below:
1. Connect the Lynx to the host PC. Windows Mobile Device Center configures USB either directly or through the Single Dock RS232 either directly or through the Single Dock Bluetooth (see par. 1.7.2) itself and then opens. device. 2. On the license agreement screen, click Accept. 3. On the Windows Mobile Device Centers Home screen, click Set up your 4. Select the information types that you want to synchronize, then click Next. 5. Enter a device name and click Set Up. When you finish the setup wizard, Windows Mobile Device Center synchronizes the mobile computer automatically. Microsoft Office Outlook emails and other information will appear on your device after synchronization. NOTE NOTE Visit the following Microsoft Web site for the latest in updates and technical information:
http://www.microsoft.com/windowsphone/en-
us/howto/wp6/sync/prepare-to-sync-windows-phone-6-5-with-my-
computer.aspx When a microSD card is inserted, Lynx allows a mass storage data connection to a host PC. This functionality can be enabled through the Control Panel. When doing so, the microSD card is not available to the Lynx. An ActiveSync connection is not possible when this feature is enabled. 1.7.2 Bluetooth, Manager Device Setup The Bluetooth Manager icon will only be visible if Bluetooth hardware has been installed on the unit. NOTE Using the Lynx to connect to another device To create a Bluetooth pairing between your device and another device that has Bluetooth capabilities, ensure that the two devices are turned on, discoverable, and within close range. 1. Open the Bluetooth control panel by tapping Start > Settings > System >
Bluetooth Manager:
2. Search for available Bluetooth devices by tapping the button for the type of device you want (Printer, Serial or All) or tap Discovery > Discover to skip this step. The Lynx will search for Bluetooth devices within range. If you attempt to set up a connection when the Bluetooth radio is disabled, you will receive a message reminding you that the radio is turned off, and asking if you want to turn it on. Tap Yes if you need to enable the Bluetooth radio. NOTE 3. Once searching is complete, Bluetooth device Profiles will be displayed in the Discovery tab. You can set up a connection to a device in the list by selecting the device and then tapping the 'Connect' button:
To create a pairing:
1. Select a service:
2. Configure any encryption, authentication, or virtual port options required by the service selected. Icon Service Dialup Networking Printer Object Push (OPP) Object Exchange (OBEX) ActiveSync Human Interface Device (HID) - Keyboard Serial Personal Area Network (PAN) Modem Headset Handsfree Virtual Port allows you to specify the incoming port, which is used to communicate serially with an incoming device just as if it were a physical COM port. This option is available only if you have selected a Printer or Serial service. You can also select Encrypt or Authenticate from the Bluetooth control panel to apply or modify those settings. 1. To require Authentication, check the checkbox, then tap OK. If required, the Authentication Request dialog will then open, requesting that you enter a PIN. Use the Input Panel or the keyboard to type the PIN. 2. 3. Tap OK to complete. The dialog will also appear when an Authentication request is received from another device. Once you have set up a Pairing, you can view the settings by double-tapping its name from the Connections tab. Tap the arrow to change the Virtual Port, or Delete to remove the device pairing. Tap Sync to initiate a Sync (available only if the service is an ActiveSync connection). Using your device to connect to the Lynx Before turning on Bluetooth, ensure that the two devices are within close range and that both Bluetooth-enabled devices are discoverable. 1. Tap Start > Settings > System > Bluetooth Manager to open the Bluetooth control panel. 2. Tap Settings. The Settings tab allows you to enable or disable the Bluetooth radio and specify settings for Incoming Connections. 3. Select or clear the Enable Bluetooth Radio check box. the Port control to select a virtual COM port to use for the connection. If youre going to be attaching a serial device (i.e. a scanner) to the Lynx, use 4. Tap Find Me if you want to make the Lynx visible to other Bluetooth devices for 60 seconds, allowing them to set up a connection. By default, Bluetooth is turned off. If you turn it on, and then turn off your device, Bluetooth also turns off. When you turn on your device again, Bluetooth turns on automatically. NOTE 1.7.3 Windows Mobile Phone For information on Windows Mobile Phone use and functioning, refer to the Windows Mobile web site: http://www.microsoft.com/windowsmobile. XPS - Virtual GPS for Windows Mobile 1.8 SKYHOOK XPS SETTINGS 1.8.1 Skyhook synthesizes data from Skyhook's Wi-Fi Positioning System (WPS), GPS satellites and cell towers with advanced hybrid positioning algorithms combining as much as possible to build a composite position and to provide the best possible location available in any environment. XPS Program Icon 1.8.2 Configuring XPS When the XPS Settings installation has completed, the settings panel will display five tabs that can be used to configure your device. The default settings should be correct for most applications. You MUST click [Apply] when changing settings on each tab. NOTE NOTE Storage tab Port tab GPS - tab Temporary folder:
Select the folder on your device or storage card where the XPS application will store data files. Temporary folder max size:
This controls the amount data storage allocated to the XPS Settings application (default setting is 4096kb). XPS Port:
Select the port that XPS will stream location data from by default, XPS will select an unused port. Disabling other serial drivers:
Use this option to disable an active device if a port for XPS is needed. COM Port:
Select the port that XPS will read the GPS data from
(default is Auto). Baudrate:
Set the baudrate for your GPS device. Description:
The description of the GPS as identified by Windows Mobile. Service tab About tab Activate / Deactivate:
Toggles the XPS service On and Off. About:
View the XPS version and copyright information. 1.8.3 Uninstalling XPS To remove XPS from your Windows Mobile device:
1. 2. 3. 4. Open the Settings panel Open the System panel Tap Remove Programs Select XPS Settings and tap remove Can I install to a storage card?
Yes however, as with most mobile apps installing to the device is recommended. FAQ and Troubleshooting 1.8.4 1. 2. What does registering XPS as my default GPS do?
3. What happens if I uninstall or deactivate XPS?
4. Ive installed but cannot get location, what is wrong?
There are several things that could cause this to happen:
Registering XPS simply sets the Windows Mobile OS to use XPS whenever an application asks for positioning. If you choose not to set XPS as the default, you will need to select the XPS COM port manually when configuring an application. XPS will reset your system settings to what they were prior to install. Do you have an internet connection? An internet connection is required after install for XPS to complete setup. An internet connection is also needed if you are moving (this connection will be present if you have data service). Do you have wi-fi disabled? Enable wi-fi and try again. Are you in an area with low numbers of access points? The WPS portion of XPS requires wireless routers to be in scanning range to provide positioning. Ive installed XPS but it will not run, what happened?
If you installed to a storage card, that card must be present in the device for XPS to function (installing to the device is the recommended configuration). My app is not providing location?
Verify that XPS is activated in the XPS Settings Service tab and that your app has the XPS port selected within your applications settings panel. My XPS settings are not being saved?
You must tap the Apply button before exiting the tab in XPS Settings. 5. 6. 7. on are updates available 1.9 DATALOGIC FIRMWARE UTILITY The Datalogic devices are equipped with a field upgradeable firmware mechanism. Firmware the Datalogic ADC website
(http://www.adc.datalogic.com/). After you have downloaded the desired update, there are several ways you can update the firmware on your device. Use Wavelink Avalanche if you have multiple Datalogic ADC devices to update. Refer to the Product CD included with your device for more information. If Wavelink Avalanche is not available or you have only a few Datalogic ADC devices to update, use the Datalogic Firmware Utility (DFU), described below, to install or update the firmware using an ActiveSync connection. The following sections provide procedures for the retrieval and installation of the most current firmware image onto a Datalogic device. 1.9.1 Retrieving a Firmware Image Update The following instructions use Internet Explorer to retrieve the most current firmware image. 1. Launch Internet Explorer on your PC and navigate to the Datalogic ADC website. Navigate to the Downloads section of the website. Select the file you want to download, then click Save to begin copying the files to your local machine (or local network location). 2. 3. Installing DFU on the Host PC 1.9.2 The Datalogic Firmware Utility (DFU) provides administrators with a field upgrade mechanism. You must have Microsoft ActiveSync (for Windows XP devices) or Windows Mobile Device Center (for Windows 7 and Vista devices) already loaded and running on the host PC to use DFU. Refer to par. 1.7.1 for more information about Windows Mobile Device Center. Prior to installing, you must remove any previous versions of DFU installed on the host PC. NOTE To install the Datalogic Firmware Utility, complete the following steps on the PC:
1. Insert the CD ROM shipped with your device into the PC and click on the link to install Datalogic Firmware Utility. OR Go to the Datalogic ADC website and download the most current version of the Datalogic Firmware Utility. Unzip the file, then double-click to run DFU_Setup. exe. Click OK to continue once you have removed previous versions of DFU. The Welcome to DFU Setup Program screen opens. Please exit all Windows applications before running this installer. Click Next to continue the Setup. Follow the onscreen instructions to complete the installation. 2. 3. 1.9.3 Updating the Firmware After copying the firmware image to the host PC (see par. 4.10.1) and installing DFU
(see par. 1.9.2), you can upgrade the firmware on your Datalogic device. The following steps require that you have already established an ActiveSync or Windows Mobile Device Center connection between the host computer and the Datalogic device. NOTE Go to Start > Programs > DFU > Datalogic Firmware Utility. Verify that ActiveSync is selected by clicking Communications > ActiveSync. Click browse (...) and navigate to the location where you saved the firmware file for your terminal. Select the current *.out file and click Open. Click Update. DFU will compare the selected firmware image with the firmware already loaded on the device; if the images are different, DFU will proceed to update the firmware image on your device. After the firmware of your device has been updated, DFU will automatically perform a warm reset of the device. 1. 2. 3. 4. 5. 6. 7. 1.10 DATALOGIC CONFIGURATION UTILITY Datalogic Configuration Utility (DCU) is a Datalogic Windows-based utility tool allowing the uploading, modifying and downloading of a Datalogic device. Configuration settings include Scanner, Control Panel, and Datalogic Desktop Utility
(DDU). The DCU installer is available on the product CD which came with your device or from the Datalogic ADC web page (http://www.adc.datalogic.com/
DCU functions in both direct (with an ActiveSync connection) and indirect (with Wavelink Avalanche) modes. In direct mode, connect a device through ActiveSync and then click on the Get from Device icon to receive the devices current configuration. Once loaded, the Configuration Tree (on the left side of the window) is used to navigate the devices configuration. The right side of the window is a work area where the values of different parameters may be set for each branch of the configuration tree. Click on the parameter group branch to open it and visualize the parameters you wish to modify. After altering the devices configuration, the new configuration can be sent to the terminal by clicking on the Send to Device icon. Reference the Wavelink Avalanche documentation on your Datalogic CD for a description of indirect mode for DCU, which will allow you to update the configuration of multiple devices simultaneously over Wi-Fi. 1.11 SUSPEND MANAGEMENT Suspend Management allows the user to keep device features powered while the device is off. The features managed by this feature are: Cellular Data/Voice and GPS. The WiFi driver has been measured to consume about 50 A when left powered. As a result, WiFi will always be left powered during suspend. This has the positive effect of substantially reducing the time required for WiFi to fully resume when the device is powered back on. NOTE Normally, the device features will behave the same as today. This means when the device is powered off, certain features (such as cellular communications) will remain powered if enabled prior to the device powering off. The behavior of each feature left powered during suspend is as follows:
Power is not removed from the feature. It can act as a wakeup source for the CPU. When the CPU wakes up, the device continues to appear "off", but the device driver on the CPU can interact with the feature. Depending on what activity takes place, any feature can optionally decide to change the system power state from Suspend to On. This would appear to the user as a wakeup event. When the user powers off the device by pressing the power key, the behavior begins similar to today:
The user is required to press the power key for at least 500 ms. After this much time, the red suspend LED turns on to provide user feedback that the power key has been recognized. If the user releases the power key in the next 1.5 seconds, the system completes the shutdown of the CPU and device features will remain powered. If instead the user continues to hold down the power key for a total of at least two seconds, then the following pop-up dialog will be displayed:
The user is given five seconds to respond. If the user selects "Yes", then the device and all features are powered off. If the user selects "No", or does not respond within five seconds, the device will power off, but leave features as they were. The term "device off" here refers to a condition where the display is off and the device appears unpowered. The device CPU may in fact be powered on. In this condition the power consumption can be relevant and battery can be completely discharged in some hours. 1.12 DATALOGIC DESKTOP UTILITY Datalogic Desktop Utility (DDU) allows Datalogic Windows administrators to configure Windows CE and Embedded Handheld devices to control individual user access. This includes:
Prevent users from changing your device OS settings. Use Application Selector to replace desktop with a selection of authorized applications. Internet Explorer access restriction, configuration and customized error recovery mechanisms. Create quick access hot keys and configure trigger actions. To open the DDU for the first time, tap Start > Settings > System > Datalogic Desktop Utility or Start > Device tools > Datalogic Desktop Utility. You can also get into DDU by pressing Alt-6. You can use DL Buttons to associate specific keys, such as <F1>-<F10>, with specific applications (see par. 1.6.3). The Alt + 6 is the button initially assigned to Datalogic Desktop Utility. If you wish to assign this key to a different function, you must first select an unassigned Button and assign it to the function Datalogic Desktop Utility. You can then go back and reassign the Button to something else. 1.12.1 Administrative Options (Admin tab) When you open the DDU control panel, the Admin tab appears. Enter Password DESCRIPTION COMMAND Enable Datalogic Desktop Select/tap this checkbox to activate the DDU functions such as Windows Access Restrictions and Application Selector. Enter a password in the text box. This allows the user to specify a password when this utility is launched. By default the password is 1234. A password can consist of all standard keyboard characters. Carefully re-enter the password in the second text box. Select/tap Set Password to enable the password. To change or remove the password, enter a new value, re-enter the new value, and select/tap Set Password. Select/tap Set Defaults to reset the default values of all the functions on all the tabs. After you select this option, you will receive a prompt to verify this selection. Re-Enter Password Set Password Set Defaults Setting a Password To set a password:
1. Enter a password in the field. This allows the user to specify a password when this utility is launched. By default the password is 1234. Be sure to record the Password for future reference. NOTE 2. Re-enter the password in the second field. 3. Select/tap Set Password to enable the password. 4. Select/tap OK to close the Set Password Confirmation dialog. You must select/tap Set Password prior to exiting DDU in order to store and activate your new password. It is not necessary to select Enable Datalogic Desktop. If you select/tap Set Defaults it will remove all custom settings and restore all the factory default settings, except a previously set password. NOTE CAUTION Changing a Password To change to a new password:
1. Enter a new value in the Enter Password field. 2. Re-enter the new value in the Re-enter Password field. 3. Select/tap Set Password. Removing a Password To remove a password:
1. Enter blanks in both Password fields. 2. Select/tap Set Password. Password Request Dialog Box Once the password is set, the next time you open the Datalogic Desktop Utility, the DDU Password dialog box opens. This dialog box will only open if a password was defined. 1. Type in your password using either the keypad on the unit, or using the stylus on the soft input panel (SIP). If you enter an incorrect password, the system will prompt you to input the cor-
rect one. 2. Select/tap OK to verify the password. Or tap X to cancel. 1.12.2 WebAppLock Options (WebAppLoc tab) Tap the "WebAppLocK tab to access the WebAppLock Configuration options. Error Page Redirection Use the Error Redirection option to provide customized recovery from common errors. When an error occurs, the browser can redirect access to a specified error page with instructions on how to recover from the problem. WebAppLock Window Features WebAppLock Configuration Tab Error Redirection options Error Type The Error Type pull-down list displays available Error Types:
(400) Invalid Syntax, (403) Request Forbidden, (404) Object Not Found, (406) No Response Format, (410) Page Doesn't Exist, (500) Internal Server Error, (501) Server Can't Do That, Generic Error, Network Disconnected Error Page Edit this textbox to associate a website or html file with the specified error. Other options Full Screen Set the web browser in full screen mode. Status Icon Enable or disable the status icons view (see par. 1.12.3). Trap Keys When checked, all key presses will be trapped by WebAppLock to prevent the user from accessing other parts of the system. DL Buttons keys will not work in WebAppLock when this box is checked. When unchecked, all system key presses, including DL Buttons keys, will work. 1.12.3 Status Icons Options (Status Tab) Tap the Status tab to access the Status Icons option. You can configure the view of some status icons that are used in WebAppLock and in Application Selector to display the status of: wi-fi radio, battery and GSM. Status Icons Options Set Status Icon Defaults Icon Size Icon Location Restores the status icons factory settings. Sets the status icons size. Selects the preferred location for each status icon. 1.12.4 Windows Controls Select/tap the Win (Windows Controls) tab to access the Windows Controls option. Use Windows controls to allow or restrict access to Windows system functions. You can disable normal Windows functions such as the taskbar, leaving nothing but a blank workspace. This allows applications to be run on the full screen and prevents users from accidental or unauthorized use of the taskbar, Internet Explorer, and any other resident applications. WINDOWS CONTROLS Taskbar Enabled AutoSIP Enabled Scroll Bars Enabled Hide Start Button Windows Wifi Error Dialog Select/tap Taskbar Enabled to specify whether the taskbar is accessible. This option is only available when the Show Taskbar is checked. Enables the AutoSIP Windows feature. This control only take effects in WebAppLock. When checked, displays horizontal and vertical scroll bars to help view large web pages which do not fit the screen. When unckecked, those scrolls will not be present. Select/tap Hide Start Button to specify whether the Start Button is displayed or not. This option works only when Task Bar Enabled is checked. This control only takes effects in WebAppLock and Internet Explorer. When checked, the device will display a warning dialog when the WiFi connected device moves out of range of an access point and the user attempts to navigate to a web page. This dialog box allows the user to reconfigure the wifi on the device. When unchecked, that dialog box will not appear and the Network Disconnected error page redirection is used to prevent users from reconfiguring the wifi on the device. Tap the WebAppLock Configuration Tab to configure the Network Disconnected error page redirection (see par 1.12.2). NOTE Settings require device rebooted 1.12.5 AppSelector Options (AppSelect tab) Tap the Application Selector (AppSelect Tab) to edit, add, or delete applications for the application selector. Application Selector Options Enable Application Selector Select/tap Enable Application Selector to enable/disable the application selector. When this is enabled, the desktop and allows only authorized use of applications. This is a list of applications that the user may access. the Application Selector replaces Authorized Applications Application Selector Commands New Select/tap New to create a new application entry. Edit Del Up/Down Select/tap Edit to edit the selected entry. Select/tap Del to delete the selected entry. Select/tap Up/Down to move an entry up or down in the ListView Add Applications The Add Application dialog opens when you tap either New or Edit. From the Add Application dialog the administrator can configure and/or add/change an a new application entry in the list. Applications with the Run Application at Startup option enabled will start automatically when the Application Selector starts up. COMMAND Application Title Executable Browse Arguments Icon File DESCRIPTION Type the name of the application in this textbox in the way you wish it to appear for the user. Displays the path for the executable file which you want to run. to browse for the desired executable file. Select/tap The results of this search are placed in the Executable textbox. Type any command line arguments to be used when an application is executed. Displays the path/link to the desired icon file. COMMAND DESCRIPTION Browse Run Application at Startup Delay OK X to browse for the desired icon file. The Select/tap results of this search are placed in the Icon File textbox. Select/tap this box to force this application to auto start when the Application Selector starts up. Applications will be started in the order listed in the authorized application list. Enter a delay duration in seconds in the combo box. This option delays auto start of application(s) to allow drivers to load prior to starting applications. Select/tap OK to add/save changes. Select/tap X to cancel the creation of this entry. 1.13 APPSELECTOR (APPLICATION SELECTOR) The Application Selector is an application that allows a device to run in kiosk mode. The administrator can choose for the user to have access to the desktop or not. The Application Selector can replace the desktop and limit the user to the specified list of applications. By default, the Application Selector comes with the WebAppLock preset. The administrator can customize this list as shown in chapter 1.12.5. To run an application, tap on its name. To exit from Application Selector, press ALT + 6, uncheck the Enable Application Selector check box on the AppSelect Tab and press OK to exit DDU. 1.14 WEBAPPLOCK (LOCKED WEB BROWSER) WebAppLock is a web browser that creates a restricted internet usage environment. It prevents the user from exiting the web application/ website set by the administrator. Zoom In and Zoom Out will only affect screen text and not bitmaps. NOTE If the taskbar has been disabled, the Settings menu is not displayed. However, the user can still navigate within the web application by using the following keyboard shortcuts:
Home Refresh Cancel Exit Ctrl + 7 Ctrl + 8 Ctrl + 9 Ctrl + 0
/E optional parameter which allows for Exit without entering a password For firmware versions 1.60 and greater, the following command line arguments are supported:
- @URL optional parameter which specifies a URL to use as a home page.
/C optional parameter which disables the ctrl keys (including the one to exit).
/W optional parameter which allows for a performance boost. When present, only WIFI error redirection will function.
/T0 optional parameter which sets the initial text size to 0 on a scale of 0 to 4.
(Default when not set is 1). The value can later be adjusted when not in full screen mode using the Font Size + and Font Size menu options.
/T1 optional parameter which sets the initial text size to 1 on a scale of 0 to 4.
(Currently does nothing) The value can later be adjusted when not in full screen mode using the Font Size + and Font Size menu options.
/T2 optional parameter which sets the initial text size to 2 on a scale of 0 to 4.
(Default when not set is 1). The value can later be adjusted when not in full screen mode using the Font Size + and Font Size menu options.
/T3 optional parameter which sets the initial text size to 3 on a scale of 0 to 4.
(Default when not set is 1). The value can later be adjusted when not in full screen mode using the Font Size + and Font Size menu options.
/T4 optional parameter which sets the initial text size to 4 on a scale of 0 to 4.
(Default when not set is 1). The value can later be adjusted when not in full screen mode using the Font Size + and Font Size menu options.
1.14.1 WebApplock Special Meta-tags General Meta-Tag Comments A meta-tag is a special HTML tag that is used to store information about a Web page but is not displayed in a Web browser. For example, meta tags provide information such as what program was used to create the page, a description of the page, and keywords that are relevant to the page. As per the HTML specification, all meta-tags must be contained within a <head>
</head> tag set. Also, the head tag set must be complete within the first 15K of the web page. The Datalogic WebAppLock defines some special meta-tags that allows the web application to interact with the device:
In particular, the special meta-tags allow to:
enable/disable the scan engine triggers enable/disable specific codes groups in the scan engine easily handle the keys pressing The trigger, decoding and DL_Keys meta tags stay in scope beyond the page they are defined in until a later page changes them. Trigger Meta-tag DL_Triggers Enable or Disable all triggers If the page contains this tag, the triggers are enable or disable depending on the content= value. Example:
<meta http-equiv="DL_Triggers" content="Disable">
CGI Error Meta-tag DL_CGIError Overrides DDU error page redirection and replaces it with a reference to a CGI script which is passed the error number as an argument. Content A CGI URL with variable name argument in place. The name of both the CGI function and the error number variable is completely configurable by the user. Do not put an = at end of the URL. HTTP header error numbers are returned if they are greater than or equal to 300. For example, 404 is returned if object is not found on the server. In addition the following WebAppLock specific error numbers are returned:
Error Number Error Condition 1000 2000 3000 4000 5000 6000 WiFi is disconnected Failed to open internet connection with WiFi Failed to connect to server Failed to open page on server Failed to send query to page on server Failed to receive query from page on server Failed to find file on device 7000 Warning: Error redirection from the WebAppLock tab in DDU will be ignored if a page has this meta-tag defined. Example:
<meta http-equiv=DL_CGIError content=http://www.SOMEWHERE.org/cgi-
bin/errorpage.plx?errornum">
In the event of a 404 error (object not found on the server), WebAppLock will navigate to the following URL:
http://www.SOMEWHERE.org/cgi-bin/errorpage.plx?errornum=404 content="Javascript:CustomerFunction">
GetSerialNumber Meta-tag DL_GetSerialNumber Obtains the device serial number and sends it as an argument to a customers javascript function. Content name of function to pass serial number to. Example:
<meta When this page is loaded the specified javascript function with the device number as the only argument (such as CustomerFunction(D10P00031). OnPowerResume Meta-tag DL_OnPowerResume Invokes the specified javascript function upon power resumption on the device. Content The URL to the JavaScript function to be called upon resume. Example:
http-equiv="DL_GetSerialNumber"
serial
<meta http-equiv="DL_OnPowerResume" content="Javascript:PowerUp()">
<meta http-equiv="DL_Reboot" content=" OnPageLoad ">
Reboot Warm boot device Meta-tag DL_Reboot Warm boot device. Content OnPageLoad Warm boot immediately upon page load. In future might have more content options. Example:
Exit Meta-tag DL_Exit Exit WebAppLock. Content OnPageLoad Exit immediately upon page load. In future might have more content options. Example:
<meta http-equiv="DL_ Exit " content=" OnPageLoad ">
Decoding meta-tags:
Each decoding meta-tag has a possible content of Enable or Disable. The settings are valid for the entire page (enable/disable each symbology). DL_Code_39 DL_Code_128 DL_Code_I25 DL_Code_S25 DL_Code_M25 DL_Code_CODABAR DL_Code_93 DL_Code_UPCA DL_Code_UPCE DL_Code_EAN13 DL_Code_EAN8 DL_Code_MSI DL_Code_MSR DL_Code_GS1_14 DL_Code_GS1_LIMIT DL_Code_GS1_EXP DL_Code_16K DL_Code_49 DL_Code_PDF417 DL_Code_DATAMATRIX DL_Code_MAXICODE DL_Code_TRIOPTIC DL_Code_PHARMA39 DL_Code_RFID DL_Code_MICROPDF417 DL_Code_COMPOSITE DL_Code_QRCODE DL_Code_AZTEC DL_Code_POSTAL Some examples:
<meta http-equiv="DL_Code_39" content="Disable">
<meta http-equiv="DL_Code_I25" content="Enable">
<meta http-equiv="DL_Key_13" content="Javascript:CheckEnter();">
Key press Metatags The key press meta-tags can be used to call JavaScript functions. They have the name structure: DL_Key_xxx where xxx is the VKey code. Example:
If one of this tag is present, the pressure of this key is handled at level of page, independently from the currently focused item. Refer to the Microsoft website to find the list of all the possible Vkey codes:
http://msdn.microsoft.com/en-us/library/bb431750.aspx http://msdn.microsoft.com/en-us/library/aa243025(VS.60).aspx The DL_Keys meta tag can exist past the page they are defined in, hence the existence of the DL_Clear meta-tag, that allows to clear all the settings and statuses. NOTE Scanning Metatags DL_Scan Captures scan results and sends barcode/tag value to a javascript function on the web page. If the content= value is a javascript function the device will be taken out of keyboard wedge mode and start listening for scan events. A scanned barcode/tag result will be used as an argument to that javascript function which is then invoked. If the content= value is Wedge then the device will stop listening for scanned event and enter keyboard wedge mode. If the content= value is Disable then the device will stop listening for scanned events but not enter keyboard wedge mode. Example:
<meta http-equiv=DL_Scan content=Javascript:ValidateInput()>
1.15 AUTOSTART The AutoStart program provides three functions:
- Allows you to create a list of applications (with optional command line arguments) to run automatically prior to loading CAB files.
- Automatically reinstalls specified CAB files when the Lynx 10 is cold booted.
- Allows you to create a list of applications (with optional command line arguments) to run automatically after loading CAB files. AutoStart launches each time the Lynx is rebooted executing each line with the specified command line arguments. It will take into account any AutoStart options at the beginning of the line. Upon a Cold Boot, AutoStart installs all the CAB files located in the \FlashDisk\CAB folder. If the CAB folder does not exist, no CAB files will be installed. AutoStart will then run the Autostart.ini from the \FlashDisk directory, executing each line with the specified command line arguments. It will take into account any AutoStart options at the beginning of the line. 1.15.1 Copy any CAB files you want to install into the \FlashDisk\CAB folder. These CAB files will then be automatically in-stalled in alphabetical order the next time you start the device. Installing CAB files 1.15.2 How AutoStart Uses Wceload If you intend to create highly interactive installers, you should either install the CABs manually or review the section on Interactive CAB Install in this chapter.. NOTE In certain environments, CAB files will be deleted after execution. To prevent the CAB file from being deleted, write protect the file before copying the file onto the device. CAUTION CAB files are installed by AutoStart using the Wceload.exe application. The following table shows available command line option:
Option
/noui Description Specifies that you will not be prompted for any input during the installation. If the CAB file is signed, any responses will automatically be answered Yes. If the CAB is unsigned, then any responses will be answered No.
/silent Suppresses dialog boxes during the installation. Please refer to the Microsoft documentation on your device for further details on Wceload.exe. Sample:
\Windows\Wceload.exe /delete 1 /noui /silent
\FlashDisk\CAB\<cab file>
Interactive CAB Install 1.15.3 If the CAB installer requires user interaction that must be performed during the AutoStart CAB installation process, you can specify a special file name to disable the silent mode installation. If this mode is specified, the CAB file will be installed with Wceload without any command line arguments specified. An example of what AutoStart would execute is:
\Windows\Wceload.exe <cab file>
To force this mode of installation via AutoStart, rename the CAB file to include a _ character before the .cab extension of the file. Example:
File.cab should be renamed File_.cab to force AutoStart to not install the CAB in silent mode. This specially-named CAB file should be placed in the AutoStart folder with other CAB files intended for installation on the next reboot. 1.15.4 Autostart.ini A file named PreAuto.ini can also be created in addition to or instead of Autostart.ini. PreAuto.ini is executed before CAB files in the \FlashDisk\Cab folder are installed. Autostart.ini is executed after CAB files in the \FlashDisk\Cab folder are installed. The format for the PreAuto.ini is identical to that of Autostart.ini.. NOTE Autostart.ini is a text file that AutoStart will run upon startup of the Lynx, and after any CAB files are installed. This file should be placed in the \FlashDisk folder. AutoStart will run the Autostart.ini file on each reboot of the device. Line Formatting Each line of the Autostart.ini can consist of Autostart options, an executable, and any command line arguments.
< Autostart option(s)> <full path to executable>
<command line arguments>
Sample:
- \windows\pword.exe \file.doc The following table breaks down the sample Autostart.ini line:
Autostart option(s) Full path to executable Command line arguments
\file.doc
\windows\pword.exe
Spaces must be placed between each component of the line in the Autostart.ini. If the executable path is in a folder that contains spaces in the name, quotes are required to distinguish what the actual executable name is. The following is an example of this:
\Program Files\ScannerApp.exe /run
(valid)
\Program Files\ScannerApp.exe /run The second line is an invalid line because there is no way to distinguish the executable from the argument.
(invalid) AutoStart Options The table below shows options you can use when writing a line in the Autostart.ini file. Description Character Comments Comment: This line will not be executed.
# OR (space) This may only be used as the first character of the line. If the comment option is specified in the options elsewhere, is ignored. it Do not wait on line completion:
This will cause to execute and immediately move onto the next line. line the
Request Query:
user confirmation when running the executable.
Execute only on Cold Reset
until This will halt parsing the Autostart.ini the confirmation is answered. This is intended for debugging the Autostart.ini file. Execute only after a warm boot %
Cold Reset Only: This will cause the line to execute only after a Cold Reset. An empty line will be treated as a comment line. NOTE Combining Options Autostart options can be combined together as shown in the following sample:
?- \Windows\Pword.exe This line would:
Request confirmation before executing the line. The next line would not be processed before the confirmation is answered. Run the next line without waiting on the current line to complete execution. Query Option The query option is intended for use when debugging the autostart.ini. When a line with this option is executed, the following dialog will appear with the specified executable and command line arguments. The populated fields shown in the AutoStart Execute Query are described the next table:
Field Description Line Number This is the line number in the script being executed. Exe Args The executable as parsed by AutoStart. The argument as parsed by AutoStart. NOTE The fields may be broken up into multiple lines (as shown in the example) due to limited space in the dialog. AutoStart Query Options Parentheses are used to surround the given field and make it very clear what the value of the field is. The following table describes the results of each choice:
Button Action Yes No Cancel The current line will execute. The current line will not execute. AutoStart will continue parsing the Autostart.ini. The current discontinue parsing the Autostart.ini. line will not execute and AutoStart will Autostart.ini Samples The next table is a collection of sample Autostart.ini lines:
Line Description
\windows\wceload.exe \My
Documents\Sample.cab
\Program Files\App.exe will the confirm execution This of
\Windows\wceload.exe with specified argument
\My Documents\Sample.cab
(invalid) This will execute argument Files\App.exe.
\Program with the
\Program Files\App.exe /run
(invalid) This will execute argument Files\App.exe /run.
\Program with the will the confirm execute program
\Program This will Files\App.exe with the argument /run. This of
\Windows\Pword.exe. If the execution is confirmed, AutoStart will immediately process the next line. This will
\Program Files\App.exe with the argument /run ONLY after a Cold Reset. execution program execute the the
\Program Files\App.exe /run
?- \Windows\Pword.exe
!\Program Files\App.exe /run 5. TECHNICAL FEATURES 1.1 TECHNICAL DATA PHYSICAL CHARACTERISTICS DIMENSIONS (LXWXH) WEIGHT
(DEPENDING ON MODEL) AUDIO LEDS DISPLAY KEYBOARD 157 x 81x 42 mm (6.18 x 3.18 x 1.65 in) 415 to 440 g (14.6 to 15.5 oz) depending on model (incl. battery) Loudspeaker Headset Six LEDs Decoding Status/ Keyboard Status/ Charging Status Reflective TFT daylight readable color display, allowing both resolution 320 x 240 pixels and 640 x 480, 89 mm (3.5 in) diagonal, 65K color, backlight, touch screen 27-key Numeric or 46-key QWERTY backlit keyboard standard. Side scan keys, push to talk and volume setting OPERATING TEMPERATURE*
STORAGE TEMPERATURE
-10 +50C (14 to 122F)
-20 +70C (-4 to 158F) HUMIDITY**
95% non condensing for temperatures < 40 C DROP RESISTANCE***
Withstands 18 drops from 1.5 m (5 ft) onto concrete ENVIROMENTAL SEALING IP64 standard for water and dust resistance ESD PROTECTION 4 KV contact discharge, 8 KV air discharge Close to the limits of the working temperature, some display and/or battery performance
* Std batteries must be charged at a temperature ranging from 0 to +40 C. High batteries must be charged at a temperature ranging from 0 to +35 C For the GSM models the maximum recommended temperature is +35C. At higher values slow down. occur. When the battery is exhausted, the GSM turns off and it is not working until the battery is
** Multiple rapid humidity and/or temperature variations may cause condensing.
*** Multiple drops can permanently damage the device. the charging may degradation may charged or changed. SYSTEM OPERATING SYSTEM MICROPROCESSOR Microsoft Windows Mobile 6.5 with Office Mobile 2010:
Outlook, Word Mobile, Excel Mobile, PowerPoint Mobile, One Note Mobile and Internet Explorer Mobile 6.0 XScale PXA310 @ 624 MHz SYSTEM RAM MEMORY 256 MB SYSTEM FLASH MEMORY 256 MB (including backup directory for user data & program permanent storage) POWER SUPPLY*
COMMUNICATIONS INTERFACES WIDE AREA NETWORK (WAN) LOCAL AREA NETWORK (LAN) PERSONAL AREA NETWORK (PAN) Removable battery pack with rechargeable Li-ion batteries; 3.7 V 3000/5000 mAh (11.10/18.50 Watt hours) Micro USB connector: USB 1.1 Client, USB 1.1 Host and Client OTG, also for supplying power; Integrated RS232 up to 115.2 Kbps, USB 1.1 Client, USB 1.1 Host UMTS HSDPA 850 1900 2100 - GSM/GPRS/EDGE 850 900 1800 1900 MHz for voice and data communication SIM socket under the battery Summit IEEE 802.11a/b/g Frequency range: Country dependent, typically 2.4 and 5.2 GHz CCX v4 Security Bluetooth Wireless Technology IEEE 802.15 Class 2 with EDR GLOBAL POSITIONING SYSTEM (GPS) Integrated GPS
* Use only DL approved power adapters. READING OPTIONS LASER CHARACTERISTICS SCANNING RATE MINIMUM RESOLUTION 104 12 scan/sec 0.10 mm / 4 mils DEPTH OF FIELD 5 to 64 cm (2 to 25 in), depending on bar code density SKEW ANGLE PITCH ANGLE AIMING LASER BAR CODES 50 65 VLD, wavelength 630~680 nm GS1 Databar, EAN/UPC, Code 39, 2/5 Codes, Plessey, Codabar, Code 128, EAN128, MSI, Code 93, Code 11 LASER CLASSIFICATION VLD - Class 2/II EN 60825-1/CDHR LED CLASSIFICATION IMAGER CHARACTERISTICS SCANNING RATE MINIMUM RESOLUTION IEC Class 1M 60 frames/sec maximum Linear codes at 3 mils; 2D codes at 5 mils AIMING LASER VLD, wavelength 645~665 nm BAR CODES LASER CLASSIFICATION LED CLASSIFICATION ILLUMINATION SYSTEM UPC A, UPC E, EAN 8, EAN 13, Interleaved 2 of 5, Code 39, Code 39 Full ASCII, Codabar, Code 128, EAN 128, Code 93, MSI, PDF417, Micro PDF, DataMatrix, QR, GS1 Databar, Aztec, Maxicode, POSTNET, PLANET, Japan Post, Australia Post, KIX Code, Royal Mail RM4SCC, USPS 4CB, UPU FICS CDRH/IEC Class II IEC Class 1M LEDs 620~630 nm 1.2 READING DIAGRAMS Typical Reading Diagram - Reading Zones (10 skew angle) Lynx 1D 400 300 200 100 0 100 200 300 400 mm 0,35 mm
(14 mils) 0,50 mm
(20 mils) 0,25 mm
(10 mils) 1,00 mm
(40 mils) 1,4 mm
(55 mils) 0,19 mm
(7,5 mils) 0,13 mm
(5 mils) 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 mm LYNX SE4500-DL Typical Reading Diagram - Reading Zones (10 skew angle) 13 mil UPC-A 20 mil Code 39 6.67 mil PDF417 10 mil PDF417 15 mil PDF417 5.0 mil PDF417 7.5 mil Code 39 5.0 mil Code 39 0 50 100 150 200 250 300 350 400 450 500 550 600 mm 200 150 100 50 0 50 100 150 200 mm 6. TEST CODES 0.25 mm (10 mils) Code 39 2/5 Interleaved Code 128 EAN 13 EAN 8 0.38 mm (15 mils) Code 39 High Density Codes
!17162H!
17162
"8Ndu 0123456784 testw test 80%
x(0B2DE5*KKKKLM(
80%
(6450*TRMN(
Medium Density Codes
!17162H!
17162
"8Ndu 0123456784 testw test 100%
x(0B2DE5*KKKKLM(
100%
(6450*TRMN(
Low Density Codes
!17162H!
17162
"8Ndu 0123456784 Interleaved 2/5 Code 128 EAN 13 EAN 8 0.50 mm (20 mils) Code 39 Interleaved 2/5 testw test 120%
120%
x(0B2DE5*KKKKLM(
(6450*TRMN(
Code 128 EAN 13 EAN 8 2D Codes Example Example Datamatrix ECC200 Inverse Datamatrix ECC200 DECODING PARAMETERS This section contains information about programmable settings for the Lynx. Use the Lynx Management Utility (FMU), the Scanner Control Panel applet, the Imaging Control Panel applets to program the Lynx. It provides the following information:
Code Parameter is the human name for the programming option. I.D. # is the decoder name for the programming option. For example, to set a Code 39 minimum label length, use I.D. 0120. Programming I.D. numbers given in this appendix can be used with all programming methods. Note that the Programming I.D. numbers are provided in hexadecimal notation. Type tells what kind of setting to use for each code parameter. On/Off is a toggle. 1 turns the parameter on, and 0 turns it off. Acceptable Input gives the settings or range of settings for each code parameter. Defaults indicates how the parameter is set when the predefined default FF39, FF3A, or FF3B is selected. Minimum (FF39) turns every on/off parameter off and sets all minimum and Maximum Label Lengths to the lowest values. Maximum (FF3A) turns every on/off parameter on, sets all Minimum Label Lengths to the lowest values, and sets all Maximum Label Lengths to the highest values. Use this default for troubleshooting; it provides the best settings for reading an unknown code symbology and can identify the symbology of scanned bar codes. Factory (FF3B) is the factory setting installed on the Lynx. This default set will work for most applications. To reset the Lynx the original defaults, scan the Factory bar code Scanner Type shows, with a checkmark, which modules support the specified parameter. PROGRAMMING CODES WITHOUT PARAMETERS The following table describes the functions of special bar codes that take no parameters:
Code Parameter Defaults Minimum Defaults Maximum Defaults Factory Defaults Registry Exit and Restore Exit and Save Exit and Commit I.D. #
FF39 FF3A Function Turns every On/Off parameter off and sets all minimum and Maximum Label Lengths to the lowest values. Turns every On/Off parameter on and sets all minimum and Maximum Label Lengths to the highest values. This default set is normally used only for troubleshooting. It gives the best chance of reading an unknown bar code symbology and also identifies the symbology of each bar code scanned. FF3B This is the default parameter settings that was installed at the factory. This default set will work for most applications. FF3C FF3D FF3E FF3F This restores all parameter settings to the values that exist in the registry. This is useful for restoring parameters to a known working set of values which have been saved using code parameter FF3F. Stops a label programming sequence and restores all parameter settings to the values that exist in the registry. Stops a label programming sequence. The last valid parameter settings are left intact. Stops a label programming sequence and writes all parameter settings into the registry. This can be used to save a customized set of parameter settings for restoring later via parameter FF3C. BAR CODE PARAMETERS The following table lists the standard customer programmable settings for the Lynx:
Codabar Defaults Scanner Type Code Parameter Description I.D.#
Accept. Input i n M x a M y r o t c a F r e s a L r e g a m I D 2 x a r o L Enable Enable Aggressive Decoding Enable Checksum Send Checksum Send Start/
Stop Convert to CLSI Allow Wide Intercharacter Gaps Minimum Label Length Enables/disables the Codabar symbology. Enables more aggressive decoding algorithms to be used in order to scan hard to read labels. Requires the use of checksum characters to verify a bar code. Instructs the terminal to include the checksum in the label transmission. Instructs the decoder to transmit the decoded start and stop characters of Codabar labels. The start and stop characters will both be translated as A, B, C, or D. Restricts the Codabar decoder to only read labels that conforms to CLSI specifications. Label length must be 14, and the data is split into fields of 1, 4, 5, and 4 characters separated by spaces. Allows wide gaps to appear between characters in a label. Set the minimum label length to be less than or equal to maximum label length. Enter 1 for On and 0 for Off 0300 On or Off Off On On 0301 On or Off Off On Off 0302 On or Off Off Off Off 0303 On or Off Off Off Off 0305 On or Off Off On Off 0306 On or Off Off Off Off 0307 On or Off Off On On 0320 01 - 50 01 01 04 Defaults Scanner Type Code Parameter Description I.D.#
Accept. Input i n M x a M y r o t c a F r e s a L r e g a m I D 2 x a r o L This feature specifies the maximum allowable length of a Codabar label. The length includes check and data characters. Maximum Label Length should be greater than or equal to Minimum Label Length. Sets the number of times a label must be read before it is transmitted. Specifies the symbology identifier (if any) that is sent when parameter Send Code ID (Index 0025) is set to 3. ASCII code zero (null) is used to indicate that an identifier is not to be sent for the symbology. Maximum Label Length Read Verification User ID 0321 01 - 50 01 50 20 0322 01 - 04 01 02 01 0323 Any single ASCII character
(00 = Off) I I I Code 39 Code Parameter Description I.D.#
Accept. Input Defaults Scanner Type i n M x a M y r o t c a F r e s a L r e g a m I D 2 x a r o L Enable Enable Aggressive Decoding Enable Checksum Send Checksum Full ASCII Mode Minimum Label Length Maximum Label Length Read Verification User ID Enables/disables the Code 39 symbology. Enables more aggressive decoding algorithms to be used in order to scan hard to read labels. Requires the use of checksum characters to verify a bar code. Instructs the terminal to include the checksum in the label transmission. Supports the entire ASCII character set by replacing various encoded ASCII characters with their corresponding. Set the minimum label length to be less than or equal to maximum label length. This feature specifies the maximum allowable length of a Code 39 label. The length includes check and data characters. Maximum Label Length should be greater than or equal to Minimum Label Length. Sets the number of times a label must be read before it is transmitted. Specifies the symbology identifier (if any) that is sent when parameter Send Code ID (Index 0025) is set to 3. ASCII code zero (null) is used to indicate that an identifier is not to be sent for the symbology. Enter 1 for On and 0 for Off 0100 On or Off Off On On 0101 On or Off Off On Off 0102 On or Off Off Off Off 0103 On or Off Off Off Off 0105 On or Off Off On On 0120 01 - 50 01 01 01 0121 01 - 50 01 50 20 0122 01 - 04 01 02 01 0123 Any single ASCII character
(00 = Off) C C C Pharmacode 39 (Code 32) Code Parameter Description I.D.#
Accept. Input Defaults Scanner Type i n M x a M y r o t c a F r e s a L r e g a m I D 2 x a r o L Enables/ disables the Pharmacode 39 (Code 32) symbology. Instructs the terminal to include the checksum in the label transmission. Instructs terminals to prefix a Pharmacode 39 label with an A prior to transmission. Specifies the symbology identifier (if any) that is sent by the decoder when parameter Send Code ID
(Index 0025) is set to 3. ASCII code zero (null) is used to indicate that an identifier is not to be sent for the symbology. Enable Send Checksum Send Start/
Stop User ID Enter 1 for On and 0 for Off 0110 On or Off Off On Off 0112 On or Off Off Off Off 0113 On or Off Off On Off 0127 Any single ASCII character
(00 = Off) Y Y Y Trioptic Code Parameter Description I.D.#
Accept. Input Defaults Scanner Type i n M x a M y r o t c a F r e s a L r e g a m I D 2 Enables/disables the Trioptic symbology. Enables more aggressive decoding algorithms to be used in order to scan hard to read labels. Sets the number of times a label must be read before it is transmitted. Specifies the symbology identifier (if any) that is sent when parameter Send Code ID (Index 0025) is set to 3. ASCII code zero (null) is used to indicate that an identifier is not to be sent for the symbology. Enter 1 for On and 0 for Off 0108 On or Off Off On Off 0109 On or Off Off On Off 0124 01 - 04 01 02 01 0125 Any single ASCII character
(00 = Off) X X X Enable Enable Aggressive Decoding Read Verification User ID x a r o L Code 93 Code Parameter Description I.D.#
Accept. Input Defaults Scanner Type i n M x a M y r o t c a F r e s a L r e g a m I D 2 x a r o L Enables/disables the Code 93 symbology. Enables more aggressive decoding algorithms to be used in order to scan hard to read labels. Set the minimum label length to be less than or equal to maximum label length. This feature specifies the maximum allowable length of a Code 93 label. The length includes check and data characters. Maximum Label Length should be greater than or equal to Minimum Label Length. Sets the number of times a label must be read before it is transmitted. Specifies the symbology identifier (if any) that is sent when parameter Send Code ID (Index 0025) is set to 3. ASCII code zero (null) is used to indicate that an identifier is not to be sent for the symbology. Enable Enable Aggressive Decoding Minimum Label Length Maximum Label Length Read Verification User ID Enter 1 for On and 0 for Off 0400 On or Off Off On Off 0401 On or Off Off On Off 0420 01 - 50 01 01 02 0421 01 - 50 01 50 20 0422 01 - 04 01 02 01 0423 Any single ASCII character
(00 = Off) L L L Code 128 Code Parameter Description I.D.#
Accept. Input Defaults Scanner Type i n M x a M y r o t c a F r e s a L r e g a m I D 2 x a r o L Enable Enable Aggressive Decoding GS1-128 Enable Code 128 Ext. ASCII Enable ISBT Concatenation Minimum Label Length Maximum Label Length Read Verification Enables/disables the Code 128 symbology. Enables more aggressive decoding algorithms to be used in order to scan hard to read labels. Enable GS1-128 variant of Code 128 (independent of Code 128). Enable Extended ASCII character conversion. This enables the ability of Code 128 labels to use the FNC4 character to encode Extended ASCII characters, as defined by the latest Code 128 symbology specification. Instructs the decoder to concatenate Code 128 labels conforming to the ISBT 128 standard. Set the minimum label length to be less than or equal to maximum label length. This feature specifies the maximum allowable length of a Code 128 label. The length includes check and data characters. Maximum Label Length should be greater than or equal to Minimum Label Length. Sets the number of times a label must be read before it is transmitted. Enter 1 for On and 0 for Off 0408 On or Off Off On On 0409 On or Off Off On Off 040C On or Off Off On Off 040F On or Off Off On On 040E On or Off Off Off Off 0424 01 - 50 01 01 02 0425 01 - 50 01 50 20 0426 01 - 04 01 02 01 Code Parameter Description I.D.#
Accept. Input User ID Specifies the symbology identifier (if any) that is sent when parameter Send Code ID (Index 0025) is set to 3. ASCII code zero
(null) is used to indicate that an identifier is not to be sent for the symbology. 0427 Any single ASCII character
(00 = Off) Defaults Scanner Type i n M x a M y r o t c a F r e s a L r e g a m I D 2 x a r o L K K K European Article Numbering-13 (EAN-13) Code Parameter Description I.D.#
Accept. Input Defaults Scanner Type i n M x a M y r o t c a F r e s a L r e g a m I D 2 x a r o L Enable Enable Aggressive Decoding Send Check Digit Send System Digit Convert EAN-
13 to ISBN Convert EAN-
13 to ISSN Enable EAN 4-
Digit Price/
Weight Check Digit Enable EAN 5-
Digit Price/
Weight Check Digit Read Verification Enables/disables the EAN-
13 symbology. Enables more aggressive decoding algorithms to be used in order to scan hard to read labels. Includes a check digit in the label which is transmitted. This instructs the decoder to include the system digit in the label transmission. For UPC-E, the system digit is zero. This instructs the decoder to identify ISBN labels and append the check digit (per ISBN guidelines) to the end of the label. This instructs the decoder to identify ISSN labels and append the check digit (per ISSN guidelines) to the end of the label. Requires the use of a 4-
digit price/ weight check digit to verify a bar code. Requires the use of a 5-
digit price/ weight check digit to verify a bar code. Sets the number of times a label must be read before it is transmitted. Enter 1 for On and 0 for Off 0510 On or Off Off On On 0511 On or Off Off On Off 0512 On or Off Off On Off 0513 On or Off Off On On 0514 On or Off Off Off Off 0515 On or Off Off Off Off 0516 On or Off Off Off Off 0517 On or Off Off Off Off 0524 01 - 04 01 02 01 Code Parameter Description I.D.#
Accept. Input Specifies the symbology identifier (if any) that is sent by the decoder when parameter Send Code ID
(Index 0025) is set to 3. ASCII code zero (null) is used to indicate that an identifier is not to be sent for the symbology. 0525 Any single ASCII character
(00 = Off) User ID Defaults Scanner Type i n M x a M y r o t c a F r e s a L r e g a m I D 2 x a r o L M M M European Article Numbering-8 (EAN-8) Code Parameter Description I.D.#
Accept. Input Defaults Scanner Type i n M x a M y r o t c a F r e s a L r e g a m I D 2 x a r o L Enter 1 for On and 0 for Off 0518 On or Off Off On On 0519 On or Off Off On Off 051A On or Off Off On Off 051B On or Off Off On Off 0526 01 - 04 01 02 01 0527 Any single ASCII character
(00 = Off) G G G Enables/disables the EAN-
8 symbology. Enables more aggressive decoding algorithms to be used in order to scan hard to read labels. Instructs the terminal to include the check digit in the label transmission. Instructs the decoder to expand EAN-8 labels to their EAN-13 equivalents. Any EAN-13 parameters will then apply to the result. Sets the number of times a label must be read before it is transmitted. Specifies the symbology identifier (if any) that is sent by the decoder when parameter Send Code ID
(Index 0025) is set to 3. ASCII code zero (null) is used to indicate that an identifier is not to be sent for the symbology. Enable Enable Aggressive Decoding Send Check Digit Convert EAN-8 to EAN-13 Read Verification User ID Universal Product Code-A (UPC-A) Code Parameter Description I.D.#
Accept. Input Defaults Scanner Type i n M x a M y r o t c a F r e s a L r e g a m I D 2 Enables/disables the UPC-
A symbology. Enables more aggressive decoding algorithms to be used in order to scan hard to read labels. Includes check digit in the label which is transmitted. Includes the system digit in the label transmission. For UPC-A, the system digit is always zero. Instructs the decoder to expand UPC-A labels to their EAN-13 equivalents. Any EAN-13 parameters will then apply to the result. Sets the number of times a label must be read before it is transmitted. Specifies the symbology identifier (if any) that is sent when parameter Send Code ID (Index 0025) is set to 3. ASCII code zero
(null) is used to indicate that an identifier is not to be sent for the symbology. Enable Enable Aggressive Decoding Send Check Digit Send System Digit Convert UPC-A to EAN-13 Read Verification User ID Enter 1 for On and 0 for Off 0500 On or Off Off On On 0501 On or Off Off On Off 0502 On or Off Off On Off 0503 On or Off Off On On 0504 On or Off Off On Off 0520 01 - 04 01 02 01 0521 Any single ASCII character
(00 = Off) A A A x a r o L Universal Product Code-E (UPC-E) Code Parameter Description I.D.#
Accept. Input Defaults Scanner Type i n M x a M y r o t c a F r e s a L r e g a m I D 2 x a r o L Enables/ disables UPC-E labels with a system digit of zero. Enables more aggressive decoding algorithms to be used in order to scan hard to read labels. Includes the check digit in the label which is transmitted. This instructs the decoder to include the system digit in the label transmission. For UPC-E, the system digit is zero. Instructs the decoder to expand UPC-E labels to their UPC-A equivalents. Any UPC-A parameters will then apply to the result. Sets the number of times a label must be read before it is transmitted. Specifies the symbology identifier (if any) that is sent when parameter Send Code ID (Index 0025) is set to 3. ASCII code zero
(null) is used to indicate that an identifier is not to be sent for the symbology. Enable System Digit 0 Enable Aggressive Decoding Send Check Digit Send System Digit Convert UPC-E to UPC-A Read Verification User ID Enter 1 for On and 0 for Off 0508 On or Off Off On On 0509 On or Off Off On Off 050A On or Off Off On Off 050B On or Off Off On Off 050C On or Off Off On Off 0522 01 - 04 01 02 01 0523 Any single ASCII character
(00 = Off) E E E UPC / EAN Extensions Code Parameter Description I.D.#
Accept. Input Defaults Scanner Type i n M x a M y r o t c a F r e s a L r e g a m I D 2 x a r o L Enable 2-
Digit Extensions Enable 5-
Digit Extensions Enable Code 128 Extensions Require Extensions Read Verification Requires a 2 digit extension
(supplemental label) to be verified for a successful decode of a label. Requires a 5 digit extension
(supplemental label) to be verified for a successful decode of a label. Enables/disables Code 128 extensions. Instructs the decoder to require any enabled UPC/EAN extensions
(supplemental labels) to be with a label in order for a scan to be successful. Sets the number of times an extension
(supplemental label) must be read before it is included in the transmission of the base UPC/EAN label. Enter 1 for On and 0 for Off 051C On or Off Off On On 051D On or Off Off On Off 051E On or Off Off On Off 051F On or Off Off On Off 0528 01 - 04 01 02 01 Interleaved 2 of 5 Code Parameter Description I.D.#
Accept. Input Defaults Scanner Type i n M x a M y r o t c a F r e s a L r e g a m I D 2 x a r o L Enable Enable Aggressive Decoding Enable Checksum Send Checksum Enable Case Code Minimum Label Length Maximum Label Length Read Verification Enables/ disables the Interleaved 2 of 5 symbology. Enables more aggressive decoding algorithms to be used in order to scan hard to read labels. Requires the use of checksum characters to verify a bar code. Instructs the terminal to include the checksum in the label transmission. Restricts Interleaved 2 of 5 label lengths to only 6 and 14 data characters. Enabling this parameter overrides the minimum and maximum length values. Set the minimum label length to be less than or equal to maximum label length. This feature specifies the maximum allowable length of an Interleaved 2 of 5 label. The length includes check and data characters. Maximum Label Length should be greater than or equal to Minimum Label Length. Sets the number of times a label must be read before it is transmitted. Enter 1 for On and 0 for Off 0210 On or Off Off On On 0211 On or Off Off On Off 0212 On or Off Off Off Off 0213 On or Off Off Off Off 0214 On or Off Off Off Off 0228 02 - 50 02 02 06 0229 02 - 50 02 50 10 022A 01 - 04 01 02 01 Code Parameter Description I.D.#
Accept. Input User ID Specifies the symbology identifier (if any) that is sent by the decoder when parameter Send Code ID
(Index 0025) is set to 3. ASCII code zero (null) is used to indicate that an identifier is not to be sent for the symbology. 022B Any single ASCII character
(00 = Off) Defaults Scanner Type i n M x a M y r o t c a F r e s a L r e g a m I D 2 x a r o L B B B Standard 2 of 5 Code Parameter Description I.D.#
Accept. Input Defaults Scanner Type i n M x a M y r o t c a F r e s a L r e g a m I D 2 x a r o L Enable Enable Aggressive Decoding Enable Checksum Send Checksum Use 2-bar Start/Stop Minimum Label Length Maximum Label Length Read Verification User ID Enables/disables the Standard 2 of 5 symbology. Enables more aggressive decoding algorithms to be used in order to scan hard to read labels. Requires the use of checksum characters to verify a bar code. Instructs the terminal to include the checksum in the label transmission. Allows the terminal to recognize labels that are printed using only two bars for start/stop characters. Set the minimum label length to be less than or equal to maximum label length. This feature specifies the maximum allowable length of a Standard 2 of 5 label. The length includes check and data characters. Maximum Label Length should be greater than or equal to Minimum Label Length. Sets the number of times a label must be read before it is transmitted. Specifies the symbology identifier (if any) that is sent when parameter Send Code ID (Index 0025) is set to 3. ASCII code zero
(null) is used to indicate that an identifier is not to be sent for the symbology. Enter 1 for On and 0 for Off 0200 On or Off Off On Off 0201 On or Off Off On Off 0202 On or Off Off Off Off 0203 On or Off Off Off Off 0204 On or Off Off Off Off 0220 01 - 50 01 01 06 0221 01 - 50 01 50 10 0222 01 - 04 01 02 01 0223 Any single ASCII character
(00 = Off) F F F Matrix 2 of 5 Code Parameter Description I.D.#
Accept. Input Defaults Scanner Type i n M x a M y r o t c a F r e s a L r e g a m I D 2 Enables/ disables the Matrix 2 of 5 symbology. Enables more aggressive decoding algorithms to be used in order to scan hard to read labels. Requires the use of checksum characters to verify a bar code. Instructs the terminal to include the checksum in the label transmission. Set the minimum label length to be less than or equal to maximum label length. This feature specifies the maximum allowable length of a Matrix 2 of 5 label. The length includes check and data characters. Maximum Label Length should be greater than or equal to Minimum Label Length. Sets the number of times a label must be read before it is transmitted. Specifies the symbology identifier (if any) that is sent by the decoder when parameter Send Code ID
(Index 0025) is set to 3. ASCII code zero (null) is used to indicate that an identifier is not to be sent for the symbology. Enable Enable Aggressive Decoding Enable Checksum Send Checksum Minimum Label Length Maximum Label Length Read Verification User ID Enter 1 for On and 0 for Off 0208 On or Off Off On Off 0209 On or Off Off On Off 020A On or Off Off Off Off 020B On or Off Off Off Off 0224 01 - 50 01 01 06 0225 01 - 50 01 50 10 0226 01 - 04 01 02 01 0227 Any single ASCII character
(00 = Off) D D D x a r o L MSI Code Parameter Description I.D.#
Accept. Input Defaults Scanner Type i n M x a M y r o t c a F r e s a L r e g a m I D 2 x a r o L Enable Enable Aggressive Decoding Require 2 Check Digits Send Check Digits 2nd Check Digit Mod 11 Minimum Label Length Maximum Label Length Read Verification User ID Enables/ disables the MSI symbology. Enables more aggressive decoding algorithms to be used in order to scan hard to read labels. An MSCI label must contain 2 check digits. This instructs the decoder to include any enabled check digit(s) in the label which is transmitted. Instructs the decoder to interpret any second MSI check digit as module 11 instead of module 10 Set the minimum label length to be less than or equal to maximum label length. This feature specifies the maximum allowable length of an MSI label. The length includes check and data characters. Maximum Label Length should be greater than or equal to Minimum Label Length. Sets the number of times a label must be read before it is transmitted. Specifies the symbology identifier (if any) that is sent by the decoder when parameter Send Code ID
(Index 0025) is set to 3. ASCII code zero (null) is used to indicate that an identifier is not to be sent for the symbology. Enter 1 for On and 0 for Off 0608 On or Off Off On Off 0609 On or Off Off On Off 060A On or Off Off Off Off 060B On or Off Off On Off 060C On or Off Off Off Off 0624 01 - 15 01 01 04 0625 01 - 15 01 15 10 0626 01 - 04 01 02 01 0627 Any single ASCII character
(00 = Off) H H H GS1 DataBar-14 Code Parameter Description I.D.#
Accept. Input Defaults Scanner Type i n M x a M y r o t c a F r e s a L r e g a m I D 2 x a r o L Enter 1 for On and 0 for Off On On Off 0800 On or Off Enables/ disables the GS1 DataBar -14 symbology. Instructs the decoder to transmit the label data as one or more UCC-128 labels. The transmission will use the UCC-128 AIM identifier. If GS1 DataBar -14, GS1 DataBar -Expanded, GS1 DataBar -Limited, or GS1 DataBar Composite symbologies are enabled for UCC-EAN 128, then that setting is also enabled for all other GS1 DataBar symbologies. For the 2D Imager, GS1 DataBar -Expanded User Code ID is used for GS1 DataBar -14. On or Off 0804 Off Off On Enable Convert to UCC-EAN 128 NOTE GS1 DataBar Limited Code Parameter Description I.D.#
Accept. Input Defaults Scanner Type i n M x a M y r o t c a F r e s a L r e g a m I D 2 x a r o L Enable Convert to UCC-EAN 128 NOTE Enter 1 for On and 0 for Off On On Off 0808 On or Off Enables/disables the GS1 DataBar Limited symbology. Instructs the decoder to transmit the label data as one or more UCC-128 labels. The transmission will use the UCC-128 AIM identifier. If GS1 DataBar -14, GS1 DataBar -Expanded, GS1 DataBar -Limited, or GS1 DataBar Composite symbologies are enabled for UCC-EAN 128, then that setting is also enabled for all other GS1 DataBar symbologies. For the 2D Imager, GS1 DataBar -Expanded User Code ID is used for GS1 DataBar -14. On or Off 080C Off Off On GS1 DataBar Expanded Code Parameter Description I.D.#
Accept. Input Defaults Scanner Type i n M x a M y r o t c a F r e s a L r e g a m I D 2 x a r o L Enables/disables the GS1 DataBar Expanded symbology. Instructs the decoder to transmit the label data as one or more UCC-128 labels. The transmission will use the UCC-128 AIM identifier. Sets the minimum bar code label length to be less than or equal to maximum label length. This feature specifies the maximum allowable length of a label. The length includes check and data characters, if applicable. Maximum Label Length should be greater than or equal to Minimum Label Length. Specifies the symbology identifier (if any) that is sent when parameter Send Code ID (Index 0025) is set to 3. ASCII code zero
(null) is used to indicate that an identifier is not to be sent for the symbology. Enable Convert to UCC-EAN 128 Minimum Maximum User Code ID Enter 1 for On and 0 for Off 0810 On or Off Off On On 0814 On or Off Off On Off 0824 1 - 74 01 74 01 0825 1 - 74 01 74 74 0827 Any single ASCII character
(00 = Off) R R R PROGRAMMABLE 2D SYMBOLOGIES Aztec Code Code Parameter Description I.D.#
Accept. Input Defaults Scanner Type i n M x a M y r o t c a F r e g a m I D 2 Enter 1 for On and 0 for Off Aztec Code Enable Aztec Code Minimum Aztec Code Maximum Aztec Code User ID Enables/disables the Aztec symbology. Set the minimum bar code label length to be less than or equal to maximum label length. This feature specifies the maximum allowable length of a label. The length includes check and data characters, if applicable. Maximum Label Length should be greater than or equal to Minimum Label Length. Specifies the symbology identifier (if any) that is sent when parameter Send Code ID (Index 0025) is set to 3. ASCII code zero (null) is used to indicate that an identifier is not to be sent for the symbology. 0B18 On or Off Off On On 0B2C 1-3750 1 3750 1 0B2D 1-3750 1 3750 3750 0B2F Any single ASCII character
(00 = Off) d d d DataMatrix Code Parameter Description I.D.#
Accept. Input Defaults Scanner Type i n M x a M y r o t c a F r e g a m I D 2 Enables/ disables the Datamatrix symbology. Set the minimum bar code label length to be less than or equal to maximum label length. This feature specifies the maximum allowable length of a label. The length includes check and data characters, if applicable. Maximum Label Length should be greater than or equal to Minimum Label Length. Specifies the symbology identifier (if any) that is sent when parameter Send Code ID (Index 0025) is set to 3. ASCII code zero (null) is used to indicate that an identifier is not to be sent for the symbology. Datamatrix Enable Datamatrix Minimum Datamatrix Maximum Datamatrix User Code ID Enter 1 for On and 0 for Off 0B00 On or Off Off On On 0B20 1-1500 1 1500 1 0B21 1-1500 1 1500 1500 0B23 Any single ASCII character
(00 = Off) V V V Composite Code Parameter Description I.D.#
Accept. Input Defaults Scanner Type i n M x a M y r o t c a F r e g a m I D 2 Composite Enable Composite to UCC/EAN-128 Composite Minimum Composite Maximum Composite User ID Enables/disables the Composite symbology. Instructs the decoder to transmit the label data as one or more UCC-128 labels. The transmission will use the UCC-128 AIM identifier. Set the minimum bar code label length to be less than or equal to maximum label length. This feature specifies the maximum allowable length of a label. The length includes check and data characters, if applicable. Maximum Label Length should be greater than or equal to Minimum Label Length. Specifies the symbology identifier (if any) that is sent when parameter Send Code ID (Index 0025) is set to 3. ASCII code zero (null) is used to indicate that an identifier is not to be sent for the symbology. Enter 1 for On and 0 for Off 0A10 On or Off Off On Off 0A14 On or Off Off Off Off 0A28 1-2435 1 2435 1 0A29 1-2435 1 2435 2435 0A2B Any single ASCII character
(00 = Off) b b b NOTE:
For the 2D Imager, GS1 DataBar -Expanded User Code ID is used for Composite. Maxicode Code Parameter Description I.D.#
Accept. Input Defaults Scanner Type i n M x a M y r o t c a F r e g a m I D 2 Enables/ disables the Maxicode symbology. Set the minimum bar code label length to be less than or equal to maximum label length. This feature specifies the maximum allowable length of a label. The length includes check and data characters, if applicable. Maximum Label Length should be greater than or equal to Minimum Label Length. Specifies the symbology identifier (if any) that is sent when parameter Send Code ID (Index 0025) is set to 3. ASCII code zero (null) is used to indicate that an identifier is not to be sent for the symbology. Maxicode Enable Minimum Label Length Maxicode Maximum Maxicode User ID Enter 1 for On and 0 for Off 0B08 On or Off Off On On 0B24 1-138 1 138 1 0B25 1-138 1 138 138 0B27 Any single ASCII character
(00 = Off) W W W PDF 417 Code Parameter Description I.D.#
Accept. Input Defaults Scanner Type i n M x a M y r o t c a F r e g a m I D 2 Enables/disables the PDF 417 symbology. Set the minimum bar code label length to be less than or equal to maximum label length. This feature specifies the maximum allowable length of a label. The length includes check and data characters, if applicable. Maximum Label Length should be greater than or equal to Minimum Label Length. Specifies the symbology identifier (if any) that is sent when parameter Send Code ID (Index 0025) is set to 3. ASCII code zero (null) is used to indicate that an identifier is not to be sent for the symbology. PDF-417 Enable PDF-417 Minimum PDF-417 Maximum PDF-417 User Code ID Enter 1 for On and 0 for Off 0A00 On or Off Off On On 0A20 1 - 2710 1 2710 1 0A21 1 - 2710 1 2710 2710 0A23 Any single ASCII character
(00 = Off) S S S MicroPDF 417 Code Parameter Description I.D.#
Accept. Input Defaults Scanner Type i n M x a M y r o t c a F r e g a m I D 2 Enables/disables the MicroPDF 417 symbology. Set the minimum bar code label length to be less than or equal to maximum label length. This feature specifies the maximum allowable length of a label. The length includes check and data characters, if applicable. Maximum Label Length should be greater than or equal to Minimum Label Length. Specifies the symbology identifier (if any) that is sent when parameter Send Code ID (Index 0025) is set to 3. ASCII code zero (null) is used to indicate that an identifier is not to be sent for the symbology. MicroPDF-417 Enable MicroPDF-417 Minimum MicroPDF-417 Maximum MicroPDF-417 User Code ID Enter 1 for On and 0 for Off 0A08 On or Off Off On Off 0A24 1 - 366 1 366 1 0A25 1 - 366 1 366 366 0A27 Any single ASCII character
(00 = Off) a a a QR Code Code Parameter Description I.D.#
Accept. Input Defaults Scanner Type i n M x a M y r o t c a F r e g a m I D 2 QR Code Enable QR Code Minimum QR Code Maximum QR Code User ID Enables/disables QR Code symbology. Set the minimum bar code label length to be less than or equal to maximum label length. This feature specifies the maximum allowable length of a label. The length includes check and data characters, if applicable. Maximum Label Length should be greater than or equal to Minimum Label Length. Specifies the symbology identifier (if any) that is sent when parameter Send Code ID (Index 0025) is set to 3. ASCII code zero (null) is used to indicate that an identifier is not to be sent for the symbology. Enter 1 for On and 0 for Off 0B10 On or Off Off On Off 0B28 1 - 3500 1 3500 1 0B29 1 - 3500 1 3500 3500 0B2B Any single ASCII character
(00 = Off) c c c Micro QR Code Enable Enables/disables Micro QR Code symbology. 0B14 On or Off Off On Off POSTAL CODES Code Parameter Description I.D.#
Accept. Input Defaults Scanner Type i n M x a M y r o t c a F r e g a m I D 2 US PostNet Enable US Planet Enable US Postal Send Chk USPS 4-State Enable UPU FICS Enable Royal Mail Enable Royal Mail Send Chk Australian Postal Enable KIX Code Enable Postal Code Redundancy Enables/ disables PostNet symbology. Enables/ disables Planet symbology. Transmit US Postal Code check digit. Enables/ disables USPS 4-
State symbology. Enables/ disables UPU FICS symbology. Enables/ disables Royal Mail symbology. Transmit Royal Mail symbology check digit. Enables/ disables Australian Postal symbology. Enables/ disables KIX Code symbology. Required number of matching reads (more than differing reads). Enter 1 for On and 0 for Off 0910 On or Off 0911 On or Off 0912 On or Off 0913 On or Off 0914 On or Off 0915 On or Off 0916 On or Off 0917 On or Off 0918 01 - 04 0928 01 - 04 Off Off Off Off Off Off Off Off 01 01 On On On On On On On On 02 02 On On On On Off On Off Off 01 01 Postal Code User ID User defined symbology ID for Postal Codes. 0929 Any single ASCII character
(00 = Off) f f f IMAGING CONTROLS Code Parameter Description I.D.#
Accept. Input Defaults Scanner Type i n M x a M y r o t c a F r e g a m I D 2 Instructs the PDT to illuminate the scanning area (independent of any targeting beam) when using an imager. Toggles between two different operating modes for the targeting beam:
Concurrent (Off): The targeting beam is turned on at the same time as an enabled illumination beam. Interlaced (On): Toggles the aimer and illumination beam. Enable the use of a target beam. Imager Illuminate Enable Imager Aim Mode Enable Aiming Beam Enter 1 for On and 0 for Off 0008 On or Off On On On 0009 On or Off On On On 000A On or Off On On On OTHER CONTROLS Code Parameter Description I.D.#
Accept. Input Defaults Scanner Type i n M x a M y r o t c a F r e s a L r e g a m I D 2 x a r o L Enable Label Programming Enables/disables the ability to perform label programming. Enter 1 for On and 0 for Off FF00 On or Off On On On Send Symbology Identifiers Specifies the symbology identifier
(if any) that is sent by the decoder when parameter Send Code ID (Index 0025) is set to 3. ASCII code zero
(null) used to indicate an identifier not to be sent for the symbology. 0025 Select symbology identifier to transmit immediately preceding scanned data:
0=None 1=DLM identifier before label:
<ID> " "
<data>
2=AIM identifier before label:
"]" <ID>
<modifier>
<data>
3=User defined identifier before label:
<ID> <data>
4=DLM identifier after label:
<data> " "
<ID>
5=AIM identifier after label:
<data> "]"
<ID>
<modifier>
6=User defined identifier after label:
<data> <ID>
00 01 00 Defaults Scanner Type Code Parameter Description I.D.#
Accept. Input i n M x a M y r o t c a F r e s a L r e g a m I D 2 x a r o L Label Prefix Label Suffix Label Separator Automatic Good Read Enable Green Spot Remove Non-
Printables GS Substitution Character sent immediately prior to symbology identifier
(0=None). Character sent immediately after final character in data
(0=None). Character sent after each string in a sample where multiple strings exist. Enable automatic Good Read on a successful read. Enable Green Spot with Good Read. Removes all characters in the range 0x00 - 0x31 or 0x7F - 0x9F from the label data. The min/max length checks made for each symbology are made before any characters are removed. Characters in the code ID, prefix, suffix, or separator will not be removed. Each occurrence of the GS character
(ASCII code 0x1D) in the label data will be substituted for the character defined by this parameter. The value 0 (NUL) is considered a valid replacement character and cannot be used to remove GS characters. 0026 0027 0028 A string of Unicode characters. A string of Unicode characters. Any single ASCII character
(00 = Off). NUL NUL NUL CR+LF CR+LF CR+LF CR CR CR 0010 On or Off 0011 On or Off On On On On On On 0018 On or Off Off Off Off 002C The maximum number of data characters is 127. All defined Unicode characters are valid. GS GS GS Code Parameter Description I.D.#
Accept. Input Decode Timeout Defines the maximum time the scanner will remain on without reading a barcode. This value does not include time spent with a spot beam (1D scanner) or target pattern (2D scanner) 002D Beeper Volume Defines the volume of decoding sounds. FF20 2 to 40
(step=1) 2 = 500 ms 40 = 10000 ms 0 to 7 = Soft to Loud 8 = lowers the volume by 1 9 = raises the volume by 1 Defaults Scanner Type i n M x a M y r o t c a F r e s a L r e g a m I D 2 x a r o L 20 20 20 7 7 7 Long Range Spot Enable Long Range Release Time Target Release Time Enable the use of a spot beam, if detected. Maximum time laser is on after trigger release using Release Scan spot beam mode. Maximum time (in seconds) imager is on after trigger release using Release Scan target beam mode. 0001 On or Off Off Off Off 0024 1-5 2 2 2 002A 1-5 2 2 2 DATALOGIC ADC LABEL IDS Datalogic ADC Label IDs UPC-A = A UPC-E = E EAN-8 = G EAN 13 = M Code 39 = C Codabar = I M 2 of 5 = D Code 93 = L MSI = H Trioptic = X Datamatrix = v Composite = s Maxicode = w PDF417 = s Pharmacode 39 = Y MicroPDF = a GS1 DataBar-14 = P QR = c Code 128 = K GS1 DataBar Limited = Q Postal Codes = f I 2 of 5 = B S 2 of 5 = F GS1 DataBar Expanded = R Aztec = d GLOSSARY Access Point A device that provides transparent access between Ethernet wired networks and IEEE 802.11 interoperable radio-equipped mobile units. Hand-held mobile computers, PDAs or other devices equipped with radio cards, communicate with wired networks using Access Points (AP). The mobile unit (mobile computer) may roam among the APs in the same subnet while maintaining a continuous, seamless connection to the wired network. Applet Diminutive form of app (application), it refers to simple, single-function programs that often ship with a larger product. Programs such as Windows' Calculator, File Manager, and Notepad are examples of applets. Barcode A pattern of variable-width bars and spaces which represents numeric or alphanumeric data in binary form. The general format of a barcode symbol consists of a leading margin, start character, data or message character, check character (if any), stop character, and trailing margin. Within this framework, each recognizable symbology uses its own unique format. Baud Rate A measure for data transmission speed. Bit Binary digit. One bit is the basic unit of binary information. Generally, eight consecutive bits compose one byte of data. The pattern of 0 and 1 values within the byte determines its meaning. Bluetooth A standard radio technology using a proprietary protocol. The onboard Bluetooth module in the device is compatible with the 1.1 protocol. Byte On an addressable boundary, eight adjacent binary digits (0 and 1) combined in a pattern to represent a specific character or numeric value. Bits are numbered from the right, 0 through 7, with bit 0 the low-order bit. One byte in memory can be used to store one ASCII character. 1 Decode To recognize a bar code symbology (e.g., Codabar, Code 128, Code 3 of 9, UPC/EAN, etc.) and analyze the content of the bar code scanned. Depth of Field (DOF) The portion of a scene that appears acceptably sharp in the image. Although a lens can precisely focus at only one distance, the decrease in sharpness is gradual on each side of the focused distance, so that within the DOF, the unsharpness is imperceptible under normal viewing conditions. EDGE Enhanced Data rates for GSM Evolution (EDGE) is a backward-compatible digital mobile phone technology that allows improved data transmission rates, as an extension on top of standard GSM. EDGE is considered a 3G radio technology and is part of ITU's 3G definition. EEPROM Electrically Erasable Programmable Read-Only memory. An on-board non-volatile memory chip. Ethernet The standard local area network (LAN) access method. A reference to "LAN," "LAN connection" or "network card" automatically implies Ethernet. Defined by the IEEE as the 802.3 standard, Ethernet is used to connect computers in a company or home network as well as to connect a single computer to a cable modem or DSL modem for Internet access. Firmware Firmware is a software program or set of instructions programmed on a hardware device. It provides the necessary instructions for how the device communicates with the other computer hardware. Firmware is typically stored in the flash ROM of a hardware device. While ROM is "read-only memory," flash ROM can be erased and rewritten because it is actually a type of flash memory. Flash Disk Non-volatile memory for storing application and configuration files. GSM Global System for Mobile communication. It is a standard for digital cellular communications, currently used in the 900 MHz and 1800 MHz bands. 2 Host A computer that serves other mobile computers in a network, providing services such as network control, database access, special programs, supervisory programs, or programming languages. WLAN A Wireless Local Area Network links devices via a wireless distribution method
(typically spread-spectrum or OFDM radio), and usually provides a connection through an access point to the wider internet. This gives users the mobility to move around within a local coverage area and still be connected to the network. IEEE 802.11 A set of standards carrying out wireless local area network (WLAN) computer communication in the 2.4, 3.6 and 5 GHz frequency bands. They are created and maintained by the IEEE LAN/MAN Standards Committee. Liquid Crystal Display (LCD) A display that uses liquid crystal sealed between two glass plates. The crystals are excited by precise electrical charges, causing them to reflect light outside according to their bias. They use little electricity and react relatively quickly. They require external light to reflect their information to the user. Light Emitting Diode (LED) A low power electronic light source commonly used as an indicator light. It uses less power than an incandescent light bulb but more than a Liquid Crystal Display (LCD). Null modem cable RS-232 serial cable where the transmit and receive lines are crosslinked. In some cables there are also handshake lines crosslinked. In many situations a straight through serial cable is used, together with a null modem adapter. The adapter contains the necessary crosslinks between the signals. Pairing A Bluetooth pairing occurs when two Bluetooth devices agree to communicate with each other and establish a connection. Piconet 3 A piconet is a Bluetooth PAN that links up to eight devices. Each piconet is controlled by one master device, and up to seven slave devices at any one time. Any device may be a member of more than one piconet, changing its membership as a user moves from one area to another. 4 RAM Random Access memory. Data in RAM can be accessed in random order, and quickly written and read. RF Radio Frequency. RTC Real Time Clock. TDMA Time division multiple access (TDMA) is digital transmission technology that allows a number of users to access a single radio-frequency (RF) channel without interference by allocating unique time slots to each user within each channel. The TDMA digital transmission scheme multiplexes three signals over a single channel. The current TDMA standard for cellular divides a single channel into six time slots, with each signal using two slots, providing a 3 to 1 gain in capacity over advanced mobile-
phone service (AMPS). Each caller is assigned a specific time slot for transmission. USB Universal Serial Bus. Type of serial bus that allows peripheral devices (disks, modems, printers, digitizers, data gloves, etc.) to be easily connected to a computer. A plug-and-play interface, it allows a device to be added without an adapter card and without rebooting the computer (the latter is known as hot-plugging). The USB standard, developed by several major computer and telecommunications companies, supports data-transfer speeds up to 12 megabits per second, multiple data streams, and up to 127 peripherals. WWAN Stands for "Wide Area Network." It is similar to a Local Area Network (LAN), but it is not limited to a single location and it uses Mobile telecommunication cellular network technologies such as UMTS, GPRS, CDMA2000, GSM, CDPD, Mobitex, HSDPA or 3G to transfer data. WWAN connectivity allows a user with a laptop and a WWAN card to surf the web, check email, or connect to a Virtual Private Network (VPN) from anywhere within the regional boundaries of cellular service. WPAN A Wireless Personal Area Network is a personal area network - a network for interconnecting devices centered around an individual person's workspace - in which the connections are wireless. Typically, a wireless personal area network uses some 5 technology that permits communication within about 10 meters - in other words, a very short range. 6 INDEX A Accessories; 20 Available Models; 10 B Batteries and Maintenance; 22 Bluetooth, Manager Device Setup; 72 Buttons; 63 C Charging the Batteries; 22 Cleaning the PDA; 29 Connections; 30 Connection to USB peripherals; 32 RS232 Connection; 34 USB Connection; 30 WLAN Connection; 35 WPAN Connections; 37 Control Panel; 62 CTIA Compliance; 150 D Data Capture; 45 Imager Data Capture; 47 Laser Data Capture; 45 Data Capture Configuration; 57 Datalogic Configuration Utility; 88 Datalogic Firmware Utility; 83 Decoding Parameters; 100 Description of the Keys; 49 E Lynx Description; 9 F FCC Compliance; 147 G General View; 7 Glossary; 153 I Industry Canada Compliance; 149 L Laser Safety; 138 LED Class; 144 LED Status; 55 M Mini SD Card Insertion; 14 P Package Contents; 12 Patents; 150 Power Supply; 137 R Radio Compliance; 145 Reading Diagrams; 94 References; 6 Replacing the Batteries; 25 Resetting the Lynx; 53 RF Exposure Information (SAR); 148 S Safety Regulations; 137 SAR Compliance; 149 Services and Support; 6 SIM Card; 17 Skyhook XPS Settings; 79 Startup; 42 Status Indicators; 55 Stylus Calibration; 66 Suspend Management; 89 T Taskbar; 56 Technical Data; 91 Technical Features; 91 Test Codes; 96 U Using the Stylus; 43 V Volume Settings; 68 W WEEE Compliance; 151 Windows Connections; 70 Windows Mobile Phone; 78 Windows Mobile Welcome Wizard; 44 Windows Mobile Device Center; 70 Wireless and Radio Frequencies Warnings; 40 Wireless Communication; 65 WWAN Connection; 38 Datalogic ADC S.r.l. Via S. Vitalino 13 40012 - Lippo di Calderara Bologna - Italy 11 dichiara che declares that the dclare que le bescheinigt ,da das Gert declare que el LYNX sono conformi alle Direttive del Consiglio Europeo sottoelencate:
are in conformity with the requirements of the European Council Directives listed below sont conformes aux spcifications des Directives de lUnion Europenne ci-dessous:
der nachstehend angefhrten Direktiven des Europischen Rats:
cumple con los requisitos de las Directivas del Consejo Europeo, segn la lista siguiente:
modelli con funzionalit radio 802.11a/b/g+BT models with 802.11a/b/g+BT radio feature modles avec 802.11a/b/g+BT radio intgrs modelle mit 802.11a/b/g+BT radio-funktionalitt modelos con funcionalidad radio 802.11a/b/g+BT 1999/5/EEC R&TTE EN 55024: 1998 AMENDMENT A1:2001 AMENDMENT A2:2003 ETSI EN 301 489-1 V1.8.1, APRIL 2008:
Questa dichiarazione basata sulla conformit dei prodotti alle norme seguenti:
This declaration is based upon compliance of the products to the following standards:
Cette dclaration repose sur la conformit des produits aux normes suivantes:
Diese Erklrung basiert darauf, da das Produkt den folgenden Normen entspricht:
Esta declaracin se basa en el cumplimiento de los productos con la siguientes normas:
EN 55022: 2006 (CLASS B ITE) , SEPTEMBER 2006 INFORMATION TECHNOLOGY EQUIPMENT AMENDMENT A1:2007 RADIO DISTURBANCE CHARACTERISTICS LIMITS AND METHODS OF MEASUREMENTS INFORMATION TECHNOLOGY EQUIPMENT IMMUNITY CHARACTERISTICS LIMITS AND METHODS OF MEASUREMENT ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS
(ERM); ELECTROMAGNETIC COMPATIBILITY (EMC) STANDARD FOR RADIO TECHNICAL EQUIPMENT REQUIREMENTS ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS
(ERM); ELECTROMAGNETIC COMPATIBILITY (EMC) STANDARD FOR RADIO EQUIPMENT; PART 17: SPECIFIC CONDITIONS FOR 2,4 GHZ WIDEBAND TRANSMISSION SYSTEMS, 5 GHZ HIGH PERFORMANCE RLAN EQUIPMENT AND 5,8 GHZ BROADBAND DATA TRANSMITTING SYSTEMS ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS
(ERM); WIDEBAND TRANSMISSION SYSTEMS; DATA TRANSMISSION EQUIPMENT OPERATING IN THE 2,4GHZ ISM BAND AND USING WIDE BAND MODULATION TECHNIQUES; HARMONIZED EN COVERING ESSENTIAL REQUIREMENTS UNDER ARTICLE 3.2 OF THE R&TTE DIRECTIVE BROADBAND RADIO ACCESS NETWORKS (BRAN);5 GHZ HIGH PERFORMANCE RLAN;HARMONIZED EN COVERING THE ESSENTIAL REQUIREMENTS OF ARTICLE 3.2 OF THE R&TTE DIRECTIVE ETSI EN 301 893 V1.5.1, DECEMBER 2008 ETSI EN 300 328 V1.7.1, OCTOBER 2006 :
ETSI EN 301 489-17 V2.1.1 MAY 2009:
SERVICES;
PART1:
COMMON AND EN 60950-1:2006 EN 62311:2008 Lippo di Calderara, June 27th 2011 INFORMATION TECHNOLOGY EQUIPMENT - SAFETY -
PART 1 : GENERAL REQUIREMENTS ASSESSMENT OF ELECTRONIC AND ELECTRICAL EQUIPMENT RELATED TO HUMAN EXPOSURE RESTRICTIONS FOR ELECTROMAGNETIC FIELDS (0 HZ - 300 GHZ) Paola Chientaroli Quality Assurance Manager Datalogic ADC S.r.l. Via S. Vitalino 13 40012 - Lippo di Calderara Bologna - Italy 11 dichiara che declares that the dclare que le bescheinigt ,da das Gert declare que el LYNX modelli con funzionalit radio Edge+BT+802.11a/b/g models with Edge+BT+802.11a/b/g radio feature modles avec Edge+BT+802.11a/b/g radio intgrs modelle mit Edge+BT+802.11a/b/g radio-funktionalitt modelos con funcionalidad radio Edge+BT+802.11a/b/g sono conformi alle Direttive del Consiglio Europeo sottoelencate:
are in conformity with the requirements of the European Council Directives listed below sont conformes aux spcifications des Directives de lUnion Europenne ci-dessous:
der nachstehend angefhrten Direktiven des Europischen Rats:
cumple con los requisitos de las Directivas del Consejo Europeo, segn la lista siguiente:
1999/5/EEC R&TTE Questa dichiarazione basata sulla conformit dei prodotti alle norme seguenti:
This declaration is based upon compliance of the products to the following standards:
Cette dclaration repose sur la conformit des produits aux normes suivantes:
Diese Erklrung basiert darauf, da das Produkt den folgenden Normen entspricht:
Esta declaracin se basa en el cumplimiento de los productos con la siguientes normas:
EN 55022: 2006 (CLASS B ITE) , SEPTEMBER 2006 AMENDMENT A1:2007 EN 55024, SEPTEMBER 1998:
AMENDMENT A1:2001 AMENDMENT A2:2003 ETSI EN 301 489-1 V1.8.1, APRIL 2008:
ETSI EN 301 489-3 V1.4.1, AUGUST 2002 :
ETSI EN 301 489-7 V1.3.1, NOVEMBER 2005 :
(ERM); ELECTROMAGNETIC COMPATIBILITY INFORMATION TECHNOLOGY EQUIPMENT RADIO DISTURBANCE CHARACTERISTICS LIMITS AND METHODS OF MEASUREMENTS INFORMATION TECHNOLOGY EQUIPMENT IMMUNITY CHARACTERISTICS LIMITS AND METHODS OF MEASUREMENT ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM
(EMC) MATTERS STANDARD FOR RADIO EQUIPMENT AND SERVICES; PART1:
COMMON TECHNICAL REQUIREMENTS ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM);ELECTROMAGNETIC COMPATIBILITY (EMC) STANDARD FOR RADIO EQUIPMENT AND SERVICES;PART 3:
SPECIFIC CONDITIONS FOR SHORT-RANGE DEVICES (SRD) OPERATING ON FREQUENCIES BETWEEN 9 KHZ AND 40 GHZ ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); ELECTROMAGNETIC COMPATIBILITY (EMC) STANDARD FOR RADIO EQUIPMENT AND SERVICES; PART 7:
SPECIFIC CONDITIONS FOR MOBILE AND PORTABLE RADIO AND ANCILLARY RADIO TELECOMMUNICATIONS SYSTEMS (GSM AND DCS) EQUIPMENT OF CELLULAR DIGITAL ETSI EN 301 489-17 V2.1.1, MAY 2009 :
ETSI EN 301 489-24 V1.4.1, SEMPTEMBER 2007 ETSI EN 301 511 V9.0.2, MARCH 2003 :
ETSI EN 301 908-1 V3.2.1, MAY 2007 ETSI EN 300 328 V1.7.1, OCTOBER 2006 :
ETSI EN 301 893 V1.5.1, DECEMBER 2008 ETSI EN 300 440-2 V1.3.1, MARCH 2009 EN 60950-1:2006 EN 50360, NOVEMBER 2001 :
EN 62311:2008 Lippo di Calderara, June 27th, 2011 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS
(ERM); ELECTROMAGNETIC COMPATIBILITY (EMC) STANDARD FOR RADIO EQUIPMENT; PART 17: SPECIFIC CONDITIONS FOR 2,4 GHZ WIDEBAND TRANSMISSION SYSTEMS, 5 GHZ HIGH PERFORMANCE RLAN EQUIPMENT AND 5,8 GHZ BROADBAND DATA TRANSMITTING SYSTEMS ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS
(ERM);ELECTROMAGNETIC COMPATIBILITY (EMC) STANDARD FOR RADIO EQUIPMENT AND SERVICES;PART 24: SPECIFIC CONDITIONS FOR IMT-2000 CDMA DIRECT SPREAD (UTRA) FOR MOBILE AND PORTABLE (UE) RADIO AND ANCILLARY EQUIPMENT GLOBAL SYSTEM FOR MOBILE COMMUNICATIONS (GSM);HARMONIZED EN FOR MOBILE STATIONS IN THE GSM 900 AND GSM 1800 BANDS COVERING ESSENTIAL REQUIREMENTS UNDER ARTICLE 3.2 OF THE R&TTE DIRECTIVE (1999/5/EC) ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS
(ERM);BASE STATIONS (BS), REPEATERS AND USER EQUIPMENT
(UE) FOR IMT-2000 THIRD-GENERATION CELLULAR NETWORKS;PART 1: HARMONIZED EN FOR IMT-2000, INTRODUCTION AND COMMON REQUIREMENTS, COVERING THE ESSENTIAL REQUIREMENTS OF ARTICLE 3.2 OF THE R&TTE DIRECTIVE ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS
(ERM); WIDEBAND TRANSMISSION SYSTEMS; DATA TRANSMISSION EQUIPMENT OPERATING IN THE 2,4GHZ ISM BAND AND USING WIDE BAND MODULATION TECHNIQUES; HARMONIZED EN COVERING ESSENTIAL REQUIREMENTS UNDER ARTICLE 3.2 OF THE R&TTE DIRECTIVE BROADBAND RADIO ACCESS NETWORKS (BRAN);5 GHZ HIGH PERFORMANCE RLAN;HARMONIZED EN COVERING THE ESSENTIAL REQUIREMENTS OF ARTICLE 3.2 OF THE R&TTE DIRECTIVE ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS
(ERM); SHORT RANGE DEVICES; RADIO EQUIPMENT TO BE USED IN THE 1 GHZ TO 40 GHZ FREQUENCY RANGE; PART 2: HARMONIZED EN UNDER ARTICLE 3.2 OF THE R&TTE DIRECTIVE INFORMATION TECHNOLOGY EQUIPMENT - SAFETY -
PART 1 : GENERAL REQUIREMENTS PRODUCT STANDARD TO DEMONSTRATE THE COMPLIANCE OF MOBILE PHONES WITH THE BASIC RESTRICTIONS RELATED TO HUMAN EXPOSURE TO ELECTROMAGNETIC FIELDS ( 300MHZ - 3GHZ ) ASSESSMENT OF ELECTRONIC AND ELECTRICAL EQUIPMENT RELATED TO HUMAN EXPOSURE RESTRICTIONS FOR ELECTROMAGNETIC FIELDS (0 HZ - 300 GHZ) Paola Chientaroli Quality Assurance Manager REFERENCES CONVENTIONS This manual uses the following conventions:
User refers to anyone using an Lynx PDA. PDA and "Lynx" refer to Lynx PDA. You refers to the System Administrator or Technical Support person using this manual to install, configure, operate, maintain or troubleshoot an Lynx PDA. Single Dock refers to the Lynx Single Slot Dock. REFERENCE DOCUMENTATION For further information regarding Lynx refer to the SDK Help on-Line. SERVICES AND SUPPORT Datalogic provides several services as well as technical support through its website. Log on to www.adc.datalogic.com and click on the links indicated for further information including:
- PRODUCTS Search through the links to arrive at your product page where you can download specific Manuals and Software & Utilities
- SERVICES & SUPPORT
- Datalogic Services Warranty Extensions and Maintenance Agreements
- Authorised Repair Centres
- CONTACT US E-mail form and listing of Datalogic Subsidiaries GENERAL VIEW C D B A E F G H M L K J I N H) Laser Safety Label I) Loudspeaker J) Color Camera K) Flash L) Product Label M) MicroSD Card Slot (under battery) N) SIM Card Slot (under battery) A) Color Display*
B) ON/OFF Power Key C) Receiver D) LEDs E) Front Scan Key F) Keyboard G) Stylus Remove protective film cover before use O P Q R S O) Side Scan Key (right) P) Up/down Volume Keys T Q) Side Scan Key (left) R) Headset Connector S) Micro USB Charging Port U T) Data Capture/Laser Output Window U) Handylink Connector (host/slave) Datalogic ADC Inc. Via S. Vitalino 13 40012 - Lippo di Calderara di Reno Bologna - Italy Lynx - Safety and Regulatory Addendum Ed.: 09/2012 2012 Datalogic ADC Inc. ALL RIGHTS RESERVED. Protected to the fullest extent under U.S. and international laws. Copying, or altering of this document is prohibited without express written consent from Datalogic ADC Inc. Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. Lynx and the Lynx logo are trademarks of Datalogic ADC Inc. All other brand and product names mentioned herein are for identification purposes only and may be trademarks or registered trademarks of their respective owners. CONTENTS 1 1.1 1.2 2 2.1 2.2 2.3 2.4 2.5 2.5.1 2.6 2.7 2.8 2.9 2.10 2.11 BATTERIES AND MAINTENANCE.................................................... 1 Charging the Battery Pack .................................................................. 1 Replacing the Battery Pack................................................................. 3 SAFETY REGULATIONS ................................................................... 6 General Safety Rules .......................................................................... 6 Power Supply ...................................................................................... 6 Laser Safety ........................................................................................ 7 LED Class ......................................................................................... 13 Radio Compliance............................................................................. 13 Information for the User..................................................................... 14 FCC Compliance............................................................................... 15 RF Exposure Information (SAR)........................................................ 16 Industry Canada Compliance............................................................ 17 SAR Compliance............................................................................... 18 Patents .............................................................................................. 18 WEEE Compliance............................................................................ 19 1 BATTERIES AND MAINTENANCE Rechargeable backup batteries and battery packs are not initially charged. Therefore the initial operation to perform is to charge them. See below. Annual replacement of rechargeable battery pack avoids possible risks or abnormalities and ensures maximum performance. NOTE CAUTION 1.1 CHARGING THE BATTERY PACK The battery pack autonomy varies according to many factors, such as the frequency of barcode scanning, RF usage, battery life, storage, environmental conditions, etc. NOTE The battery icon on the Taskbar indicates when the battery pack is low. It is possible to recharge the battery pack by connecting the power supply directly to the Lynx. Alternatively, it is also possible to recharge the battery pack by using a Single Cradle or the Lynx Multi Battery Charger. Moreover recharging is possible by USB Direct connection with the host computer, but with longer charging times. During the charging process the LED positioned at the right side of the display is red constant. Once the charging process has been completed this LED is green constant. If the battery pack is removed from the mobile computer, it can be recharged by inserting it into the rear slot of a Single Cradle or the Lynx Multi Battery Charger.. Do not use the Lynx until standard batteries are charged for minimum 4 hours and extended batteries are charged for minimum 6 hours. CAUTION 1 Even if the storage temperature range is wider, In order to achieve the longest battery life, store the terminal and the spare batteries between 20 to 30 C (68 to 86 F). The Batteries must be charged at a temperature ranging from 0 to +44 C (+33.8 to +111.2 F). The battery level may not be displayed correctly for some minutes after the disconnection if the Lynx is disconnected from power supply before the charging cycle is completed. The Lynx could get warm during charging, this is normal and does not mean a malfunction. Use only a USB-IF compliant USB port as a charging source. NOTE NOTE NOTE NOTE 2 1.2 REPLACING THE BATTERY PACK To correctly replace the battery pack, proceed as follows. 1. Turn off the Lynx. 2. Shift the battery latch to the left and remove the battery pack:
3. Install the new battery pack, first insert the bottom (contacts) and then the upper side of the battery pack into the slot. Press until the battery latch clicks. 3 Installing, charging and/or any other action should be done by authorized personnel and following this manual. The battery pack may get hot, explode, ignite, and/or cause serious injury if exposed to abusive conditions. If the battery pack is replaced with an improper type, there is risk of explosion. Do not place the battery pack in or near a fire or heat; do not place the battery pack in direct sunlight, or use or store the battery pack inside unventilated areas in hot weather; do not place the battery pack in microwave ovens, dryer, high pressure containers, on induction cookware or similar device. Doing so may cause the battery pack to generate heat, explode or ignite. Using the battery pack in this manner may also result in a loss of performance and a shortened life expectancy. Use only a Datalogic Mobile approved power supply. The use of an alternative power supply will void the product warranty, may cause product damage and may cause heat, explode or ignite. The area in which the units are charged should be clear of debris and combustible materials or chemicals. Do not use the battery pack of this terminal for power devices different from this mobile computer. Immediately discontinue use of the battery pack if, while using, charging or storing the battery pack, the battery pack emits an unusual smell, feels hot, changes colour or shape, or appears abnormal in any other way. Do not short-circuit the battery pack contacts connecting the positive terminal and negative terminal. This might happen, for example, when you carry a spare battery pack in your pocket or purse; accidental shortcircuiting can occur when a metallic object such as a coin, clip, or pen causes direct connection of the contacts of the battery pack (these look like metal strips on the battery pack). Shortcircuiting the terminals may damage the battery pack or the connecting object. Do not apply voltages to the battery pack contacts. Do not pierce the battery pack with nails, strike it with a hammer, step on it or otherwise subject it to strong impacts or shocks. WARNING 4 WARNING If liquid the skin or eyes. Do not disassemble or modify (i.e. bend, crush or deform) the battery pack. The battery pack contains safety and protection devices, which, if damaged, may cause the battery pack to generate heat, explode or ignite. In case of leakage of liquid from the battery, avoid contact with the contact occurs, immediately wash the affected area with water and consult a doctor. Do not solder directly onto the battery pack. Do not expose the battery pack to liquids. Avoid any knocks or excessive vibrations. If the device or the battery is dropped, especially on a hard surface, you should take it to the nearest Authorised Repair Centre for inspection before continuing to use it. Do not replace the battery pack when the device is turned on. Do not remove or damage the battery packs label. Do not use the battery pack if it is damaged in any part. Battery pack usage by children should be supervised. Collect and recycle waste batteries separately from the device in comply with European Directive 2006/66/EC, 2002/95/EC, 2002/96/EC and subsequent modifications, US and China regulatory and others laws and regulations about environment. In order to guarantee an adequate operating autonomy, when replacing the battery pack the mobile computer checks the battery energy level. If the battery is not sufficiently charged, the Lynx does not turn on (when pressing the ON/OFF key). In this case, either substitute the battery pack with a charged one (sufficiently charged) or insert the Lynx into a powered cradle or plug it into the direct power supply. To achieve the best battery life, turn off the radios not in use. NOTE NOTE 5 2 SAFETY REGULATIONS Read this manual carefully before performing any type of connection to the Lynx mobile computer. The user is responsible for any damages caused by incorrect use of the equipment or by inobservance of the indication supplied in this manual. NOTE 2.1 GENERAL SAFETY RULES Use only the components supplied by the manufacturer for the specific Lynx being used. Do not attempt to disassemble the Lynx mobile computer, as it does not contain parts that can be repaired by the user. Any tampering will invalidate the warranty. When replacing the battery pack or at the end of the operative life of the Lynx mobile computer, disposal must be performed in compliance with the laws in force. Before using the devices and the battery packs, read chapter 1. Do not submerge the Lynx in liquid products. For further information, refer to this manual and to the Datalogic Mobile web site: www.adc.datalogic.com. 2.2 POWER SUPPLY This device is intended to be connected to a UL Listed/CSA Certified computer which supplies power directly to the Lynx or else be supplied by a UL Listed/CSA Certified Power Unit marked Class 2 or LPS power source rated 5 V, 1.8 A, which supplies power directly to the Lynx via the power connector of the cable. The package includes three international plug adapters. The adapters must be plugged in the power supply before the power supply itself is plugged on the wall outlet. 6 2.3 LASER SAFETY The laser light is visible to the human eye and is emitted from the window indicated in the figure. This information applies to both laser models and the Lynx Imager Aiming System. Laser output window 7 I D F E La luce laser visibile all'occhio umano e viene emessa dalla finestra indicata nella figura. LUCE LASER NON FISSARE IL FASCIO APPARECCHIO LASER DI CLASSE 2 MASSIMA POTENZA DI USCITA: 1.7mW LUNGHEZZA D'ONDA EMESSA: 650nm CONFORME A IEC 60825-1 (2007) Die Laserstrahlung ist fr das menschliche Auge sichtbar und wird am Strahlaustrittsfenster ausgesendet (siehe Bild). LASERSTRAHLUNG NICHT IN DER STRAHL BLINKEN PRODUKT DER LASERKLASSE 2 MAXIMALE AUSGANGLEISTUNG:
1.7mW WELLENLNGE:
650nm ENTSPR. IEC 60825-1
(2007) Le rayon laser est visible l'oeil nu et il est mis par la fentre dsigne sur l'illustration dans la figure. La luz lser es visible al ojo humano y es emitida por la ventana indicada en la figura. RAYON LASER EVITER DE REGARDER LE RAYON APPAREIL LASER DE CLASSE 2 MAXIMUM PUISSANCE DE SORTIE: 1.7mW LONGUER D'ONDE EMISE: 650nm CONFORME A IEC 60825-1 (2007) RAYO LSER NO MIRAR FIJO EL RAYO APARATO LSER DE CLASE 2 MXIMA POTENCIA DE SALIDA: 1.7mW LONGITUD DE ONDA EMITIDA: 650nm CONFORME A IEC 60825-1
(2007) 8 ENGLISH The following information is provided to comply with the rules imposed by international authorities and refers to the correct use of your mobile computer. STANDARD LASER SAFETY REGULATIONS This product conforms to the applicable requirements of both CDRH 21 CFR 1040 Subchapter J and IEC 60825-1:2007 at the date of manufacture. For installation, use and maintenance, it is not necessary to open the device. Do not attempt to open or otherwise service any components in the optics cavity. Opening or servicing any part of the optics cavity by unauthorized personnel may violate laser safety regulations. The optics system is a factory only repair item. Use of controls or adjustments or performance of procedures other than those specified herein may result in exposure to hazardous visible laser light. CAUTION CAUTION The product utilizes a low-power laser diode. Although staring directly at the laser beam momentarily causes no known biological damage, avoid staring at the beam as one would with any very strong light source, such as the sun. Avoid that the laser beam hits the eye of an observer, even through reflective surfaces such as mirrors, etc. CAUTION Use of optical systems with the scanner will increase eye hazard. Optical binoculars, microscopes, eye glasses and magnifying glasses. instruments include ITALIANO informazioni vengono fornite dietro direttive delle autorit Le seguenti internazionali e si riferiscono alluso corretto del terminale. NORMATIVE STANDARD PER LA SICUREZZA LASER Questo prodotto risulta conforme alle normative vigenti sulla sicurezza laser alla data di produzione: CDRH 21 CFR 1040 sezione J e IEC 60825-1:2007. Non si rende mai necessario aprire lapparecchio per motivi di installazione, utilizzo o manutenzione. 9 ATTENZIONE Non tentare di accedere allo scomparto contenete i componenti ottici o di farne la manutenzione. Lapertura dello scomparto, o la manutenzione di qualsiasi parte ottica da parte di personale non autorizzato, potrebbe violare le norme della sicurezza. Il sistema ottico pu essere riparato solamente alla fabbrica. L'utilizzo di procedure o regolazioni differenti da quelle descritte provocare un'esposizione pericolosa a luce laser visibile. documentazione nella pu ATTENZIONE Il prodotto utilizza un diodo laser a bassa potenza. Sebbene non siano noti danni riportati dallocchio umano in seguito ad una esposizione di breve durata, evitare di fissare il raggio laser cos come si eviterebbe qualsiasi altra sorgente di luminosit intensa, ad esempio il sole. Evitare inoltre di dirigere il raggio laser negli occhi di un osservatore, anche attraverso superfici riflettenti come gli specchi. ATTENZIONE Luso di strumenti ottici assieme allo scanner pu aumentare il pericolo di danno agli occhi. Tali strumenti ottici includono cannocchiali, microscopi, occhiali e lenti di ingrandimento. DEUTSCH Die folgenden Informationen stimmen mit den Sicherheitshinweisen berein, die von internationalen Behrden auferlegt wurden, und sie beziehen sich auf den korrekten Gebrauch vom Terminal. NORM FR DIE LASERSICHERHEIT Dies Produkt entspricht am Tag der Herstellung den gltigen EN 60825-1:2007 und CDRH 21 CFR 1040 Subchapter J Normen fr die Lasersicherheit. Es ist nicht notwendig, das Gert wegen Betrieb oder Installations-, und Wartungs-Arbeiten zu ffnen. ACHTUNG Unter keinen Umstnden darf versucht werden, die Komponenten im Optikhohlraum zu ffnen oder auf irgendwelche andere Weise zu warten. Das ffnen bzw. im Optikhohlraum durch Warten der Komponenten unbefugtes Personal verstt gegen die Laser-
Sicherheitsbestimmungen. Das Optiksystem darf nur werkseitig repariert werden. 10 Jegliche nderungen am Gert sowie Vorgehensweisen, die nicht in dieser Betriebsanleitung beschrieben werden, knnen ein gefhrliches Laserlicht verursachen. ACHTUNG Der Produkt benutzt eine Laserdiode. Obwohl zur Zeit keine Augenschden von kurzen Einstrahlungen bekannt sind, sollten Sie es vermeiden fr lngere Zeit in den Laserstrahl zu schauen, genauso wenig wie in starke Lichtquellen (z.B. die Sonne). Vermeiden Sie es, den Laserstrahl weder gegen die Augen eines Beobachters, noch gegen reflektierende Oberflchen zu richten. ACHTUNG Die Verwendung von Optiksystemen mit diesem Scanner erhht die Gefahr einer Augenbeschdigung. Zu optischen Instrumenten gehren unter anderem Fernglser, Mikroskope, Brillen und Vergrerungsglser. FRANAIS Les informations suivantes sont fournies selon les rgles fixes par les autorits internationales et se rfrent une correcte utilisation du terminal. NORMES DE SECURITE LASER Ce produit est conforme aux normes de scurit laser en vigueur sa date de fabrication: CDRH 21 CFR 1040 sous-chapitre J et IEC 60825-1:2007. Il nest pas ncessaire douvrir lappareil pour linstallation, lutilisation ou lentretien. Ne pas essayer douvrir ou de rparer les composants de la cavit optique. Louverture de la cavit optique ou la rparation de ses composants par une personne non qualifie peut entraner le nonrespect des rgles de scurit relatives au laser. Le systme optique ne peut tre rpar quen usine. L'utilisation de procdures ou rglages diffrents de ceux donns ici peut entraner une dangereuse exposition lumire laser visible. ATTENTION ATTENTION Le produit utilise une diode laser. Aucun dommage aux yeux humains na t constat la suite dune exposition au rayon laser. Eviter de regarder fixement le rayon, comme toute autre source lumineuse intense telle que le soleil. Eviter aussi de diriger le rayon vers les yeux dun observateur, mme travers des surfaces rflchissantes (miroirs, par exemple). 11 Lutilisation dinstruments optiques avec le scanneur augmente le danger pour les yeux. Les instruments optiques comprennent les jumelles, les microscopes, les lunettes et les verres grossissants. ATTENTION ESPAOL Las informaciones siguientes son presentadas en conformidad con las disposiciones de las autoridades internacionales y se refieren al uso correcto del terminal. NORMATIVAS ESTNDAR PARA LA SEGURIDAD LSER Este aparato resulta conforme a las normativas vigentes de seguridad lser a la fecha de produccin: CDRH 21 CFR 1040 Seccin J y IEC 60825-1:2007. No es necesario abrir el aparato para la instalacin, la utilizacin o la manutencin. No intente abrir o de ninguna manera dar servicio a ninguno de los componentes del receptculo ptico. Abrir o dar servicio a las piezas del receptculo ptico por parte del personal no autorizado podra ser una violacin a los reglamentos de seguridad. El sistema ptico se puede reparar en la fbrica solamente. La utilizacin de procedimientos o regulaciones diferentes de aquellas describidas en la documentacin puede causar una exposicin peligrosa a la luz lser visible. ATENCIN ATENCIN El aparato utiliza un diodo lser a baja potencia. No son notorios daos a los ojos humanos a consecuencia de una exposicin de corta duracin. Eviten de mirar fijo el rayo lser as como evitaran cualquiera otra fuente de luminosidad intensa, por ejemplo el sol. Adems, eviten de dirigir el rayo lser hacia los ojos de un observador, tambin a travs de superficies reflectantes como los espejos. El uso de sistemas pticos con el escner aumentar el riesgo de daos oculares. Los instrumentos pticos incluyen binoculares, microscopios, lentes y lupas. ATENCIN 12 2.4 LED CLASS LED illuminators integrated in the LYNX models with SE-4500 imager engine are compliant with exempt risk group requirements according to IEC62471:2006 and EN62471:2008. Flash LED integrated in the LYNX models with camera is blue light hazard risk group 1 according to IEC62471:2006 and EN62471:2008 2.5 RADIO COMPLIANCE In radio systems configured with mobile computers and access points, the frequencies to be used must be allowed by the spectrum authorities of the specific country in which the installation takes place. Be absolutely sure that the system frequencies are correctly set to be compliant with the spectrum requirements of the country. The Radio modules used in this product automatically adapt to the frequencies set by the system and do not require any parameter settings. The TYPE field shows the correspondence between LYNX types and radio modules:
TYPE: ABCDEE-FGH-IJJK-LMMMM A: 0 if WWAN module is not present, E for GSM/GPRS/EDGE WWAN module, U for UMTS/HSDPA WWAN module, H for UMTS HSPA+ Voice and Data B: 0 if GPS module is not present C: 0 if IEEE 802.11 module is not present, A for IEEE 802.11 abg module, G for IEEE 802.11 bg module, N for IEEE 802.11 bgn module D: 0 if RFID module is not present. 13 2.5.1 Information for the User ENGLISH Contact the competent authority responsible for the management of radio frequency devices of your country to verify any possible restrictions or licenses required. Refer to the web site http://europa.eu.int/comm/enterprise/rtte/spectr.htm for further information. ITALIANO Prendi contatto con l'autorit competente per la gestione degli apparati a radio frequenza del tuo paese, per verificare eventuali restrizioni o licenze. Ulteriori informazioni sono disponibili sul sito:
http://europa.eu.int/comm/enterprise/rtte/spectr.htm. FRANAIS Contactez l'autorit comptente en la gestion des appareils radio frquence de votre pays pour vrifier d'ventuelles restrictions ou licences. Pour tout renseignement vous pouvez vous adresser au site web:
http://europa.eu.int/comm/enterprise/rtte/spectr.htm. DEUTSCH Wenden Sie sich an die fr Radiofrequenzgerte zustndige Behrde Ihres Landes, um zu prfen ob es Einschrnkungen gibt, oder eine Lizenz erforderlich ist. Weitere Informationen finden Sie auf der Web Seite:
http://europa.eu.int/comm/enterprise/rtte/spectr.htm. ESPAOL Contacta la autoridad competente para la gestin de los dispositivos de radio frecuencia de tu pas, para verificar cualesquiera restricciones o licencias posibles requerida. Adems se puede encontrar mas informacin en el sitio Web:http://europa.eu.int/comm/enterprise/rtte/spectr.htm 14 2.6 FCC COMPLIANCE FCC Regulations:
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiated radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. 15 2.7 RF EXPOSURE INFORMATION (SAR) This model device meets the governments requirements for exposure to radio waves. This device is designed and manufactured not to exceed the emission limits for exposure to radio frequency (RF) energy set by the Federal Communications Commission of the U.S. Government. The exposure standard for wireless devices employs a unit of measurement known as the Specific Absorption Rate, or SAR. The SAR limit set by the FCC is 1.6W/kg. *Tests for SAR are conducted using standard operating positions accepted by the FCC with the device transmitting at its highest certified power level in all tested frequency bands. Although the SAR is determined at the highest certified power level, the actual SAR level of the device while operating can be well below the maximum value. This is because the device is designed to operate at multiple power levels so as to use only the poser required to reach the network. In general, the closer you are to a wireless base station antenna, the lower the power output. While there may be differences between the SAR levels of various devices and at various positions, they all meet the government requirement. The FCC has granted an Equipment Authorization for this model device with all reported SAR levels evaluated as in compliance with the FCC RF exposure guidelines. SAR information on this model device is on file with the FCC and can be found under the Display Grant section of http://www.fcc.gov/oet/fccid after searching on the below FCC ID: FCC ID: U4G0070 and U4G0073 This device is compliant with SAR for general population /uncontrolled exposure limits in ANSI/IEEE C95.1-1999 and had been tested in accordance with the measurement methods and procedures specified in OET Bulletin 65 Supplement C. For body worn operation, this device has been tested and meets the FCC RF exposure guidelines for use with an accessory that contains no metal and the positions the handset a minimum of 1.5 cm from the body. Use of other enhancements may not ensure compliance with FCC RF exposure guidelines. If you do not use a body-worn accessory and are not holding the device at the ear, position the handset a minimum of 1.5 cm from your body when the device is switched on. 16 INDUSTRY CANADA COMPLIANCE 2.8 Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numrique de la classe B est conforme la norme NMB-003 du Canada. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter. The County Code Selection feature is disabled for products marketed in the US/Canada. IMPORTANT NOTE:
IC Radiation Exposure Statement This EUT is compliant with SAR for general population/uncontrolled exposure limits in IC RSS-102 and had been tested in accordance with the measurement methods and procedures specified in IEEE 1528. This equipment should be installed and operated with minimum distance 1,5cm between the radiator &
your body. 17 2.9 SAR COMPLIANCE 1. For the used worst case positions, the portable device Lynx from Datalogic
(FCC ID: U4G0070 and U4G0073) is in compliance with the IC RSS 102 Issue 4 [RSS 102] and Federal Communications Commission (FCC) Guidelines [OET 65] for uncontrolled exposure. SAR assessment in body worn was conducted with a distance of 15 mm between the housing of the handheld and the flat phantom. 2. EN 50360:2001: product standard to demonstrate the compliance of mobile phones with the basic restrictions related to human exposure to electromagnetic fields (300 MHz 3 GHz). 3. EN 62209-1:2006 : Human exposure to radio frequency fields from hand-
held and body-mounted wireless communication devices. Human models, instrumentation, and procedures. Procedure to determine the specific absorption rate (SAR) for hand-held devices used in close proximity to the ear (frequency range of 300 MHz to 3 GHz) 4. EN 62209-2 :2010: Human exposure to radio frequency fields from hand-
held and body-mounted wireless communication devices. Human models, instrumentation, and procedures. Procedure to determine the specific absorption rate (SAR) for wireless communication devices used in close proximity to the human body (frequency range of 30 MHz to 6 GHz) 2.10 PATENTS This product is covered by one or more of the following patents:
Design Pat.: EP 1711946; US D633502; CN ZL201030189483.7. Utility Patents: EP681257. Additional patents pending. 18 2.11 WEEE COMPLIANCE Informazione degli utenti ai sensi della Direttiva Europea 2002/96/EC Lapparecchiatura che riporta il simbolo del bidone barrato deve essere smaltita, alla fine della sua vita utile, separatamente dai rifiuti urbani. Smaltire lapparecchiatura in conformit alla presente Direttiva consente di:
evitare possibili conseguenze negative per lambiente e per la salute umana che potrebbero invece essere causati dallerrato smaltimento dello stesso;
recuperare materiali di cui composto al fine di ottenere un importante risparmio di energia e di risorse. Per maggiori dettagli sulle modalit di smaltimento, contattare il Fornitore dal quale stata acquistata lapparecchiatura o consultare la sezione dedicata sul sito www.mobile.datalogic.com. Information for the user in accordance with the European Commission Directive 2002/96/EC At the end of its useful life, the product marked with the crossed out wheeled wastebin must be disposed of separately from urban waste. Disposing of the product according to this Directive:
avoids potentially negative consequences to the environment and human health which otherwise could be caused by incorrect disposal enables the recovery of materials to obtain a significant savings of energy and resources. For more detailed information about disposal, contact the supplier that provided you with the product in question or consult the dedicated section at the website www.mobile.datalogic.com. Information aux utilisateurs concernant 2002/96/EC Au terme de sa vie utile, le produit qui porte le symbole d'un caisson ordures barr ne doit pas tre limin avec les dchets urbains. liminer ce produit selon cette Directive permet de:
la Directive Europenne 19 viter les retombes ngatives pour l'environnement et la sant drivant d'une limination incorrecte rcuprer les matriaux dans le but d'une conomie importante en termes d'nergie et de ressources informations complmentaires concernant Pour obtenir des l'limination, veuillez contacter le fournisseur auprs duquel vous avez achet le produit ou consulter la section consacre au site Web www.mobile.datalogic.com. Informacin para el usuario de accuerdo con la Directiva Europea 2002/96/CE Al final de su vida til, el producto marcado con un simbolo de contenedor de bassura mvil tachado no debe eliminarse junto a los desechos urbanos. Eliminar este producto de accuerdo con la Directiva permite de:
evitar posibles consecuencias negativas para el medio ambiente y la salud derivadas de una eliminacin inadecuada recuperar los materiales obteniendo as un ahorro importante de energa y recursos Para obtener una informacin ms detallada sobre la eliminacin, por favor, pngase en contacto con el proveedor donde lo compr o consultar la seccin dedicada en el Web site www.mobile.datalogic.com. Benutzerinformation bezglich Richtlinie 2002/96/EC der europischen Kommission Am Ende des Gertelebenszyklus darf das Produkt nicht ber den stdtischen Hausmll entsorgt werden. Eine entsprechende Mlltrennung ist erforderlich. Beseitigung des Produkts entsprechend der Richtlinie:
verhindert negative Auswirkungen fr die Umwelt und die Gesundheit der Menschen ermglicht die Wiederverwendung der Materialien und spart somit Energie und Resourcen Weitere Informationen zu dieser Richtlinie erhalten sie von ihrem Lieferanten ber den sie das Produkt erworben haben, oder besuchen sie unsere Hompage unter www.mobile.datalogic.com. 20 Datalogic ADC s.r.l. Via S. Vitalino 13 40012 Calderara di Reno Bologna - Italy 12 dichiara che declares that the dclare que le bescheinigt ,da das Gert declare que el LYNX sono conformi alle Direttive del Consiglio Europeo sottoelencate:
are in conformity with the requirements of the European Council Directives listed below sont conformes aux spcifications des Directives de lUnion Europenne ci-dessous:
der nachstehend angefhrten Direktiven des Europischen Rats:
cumple con los requisitos de las Directivas del Consejo Europeo, segn la lista siguiente:
modelli con funzionalit radio 802.11b/g/n+BT models with 802.11b/g/n+BT radio feature modles avec 802.11b/g/n+BT radio intgrs modelle mit 802.11b/g/n+BT radio-funktionalitt modelos con funcionalidad radio 802.11b/g/n+BT 2004/108 and 1999/5/EEC R&TTE Questa dichiarazione basata sulla conformit dei prodotti alle norme seguenti:
This declaration is based upon compliance of the products to the following standards:
Cette dclaration repose sur la conformit des produits aux normes suivantes:
Diese Erklrung basiert darauf, da das Produkt den folgenden Normen entspricht:
Esta declaracin se basa en el cumplimiento de los productos con la siguientes normas:
EN 55022: 2010 (CLASS B ITE) INFORMATION TECHNOLOGY EQUIPMENT RADIO DISTURBANCE CHARACTERISTICS LIMITS AND METHODS OF MEASUREMENTS INFORMATION TECHNOLOGY EQUIPMENT IMMUNITY CHARACTERISTICS LIMITS AND METHODS OF MEASUREMENT ELECTROMAGNETIC COMPATIBILITY AND RADIO
(ERM); ELECTROMAGNETIC SPECTRUM MATTERS FOR RADIO COMPATIBILITY EQUIPMENT AND SERVICES; PART1: COMMON TECHNICAL REQUIREMENTS ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); ELECTROMAGNETIC COMPATIBILITY
(EMC) STANDARD FOR RADIO EQUIPMENT; PART 17: SPECIFIC CONDITIONS FOR 2,4 GHZ WIDEBAND TRANSMISSION SYSTEMS, 5 GHZ HIGH PERFORMANCE RLAN EQUIPMENT AND 5,8 GHZ BROADBAND DATA TRANSMITTING SYSTEMS
(EMC) STANDARD EN 55024: 2010 ETSI EN 301 489-1 V 1.9.2 : 2011 ETSI EN 301 489-17 V 2.1.1: 2009 EN COVERING ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS
(ERM); WIDEBAND TRANSMISSION SYSTEMS; DATA TRANSMISSION EQUIPMENT OPERATING IN THE 2,4GHZ ISM BAND AND USING WIDE BAND MODULATION TECHNIQUES;
HARMONIZED ESSENTIAL REQUIREMENTS UNDER ARTICLE 3.2 OF THE R&TTE DIRECTIVE INFORMATION TECHNOLOGY EQUIPMENT - SAFETY -
PART 1 : GENERAL REQUIREMENTS INFORMATION TECHNOLOGY EQUIPMENT - SAFETY -
PART 1 : GENERAL REQUIREMENTS SOUND SYSTEM EQUIPMENT - HEADPHONES AND EARPHONES ASSOCIATED WITH PORTABLE AUDIO EQUIPMENT - MAXIMUM SOUND PRESSURE LEVEL LIMIT MEASUREMENT CONSIDERATIONS - PART 2: MATCHING OF SETS WITH HEADPHONES IF EITHER OR BOTH ARE OFFERED SEPARATELY SAFETY OF LASER PRODUCTS - PART 1: EQUIPMENT CLASSIFICATION AND REQUIREMENTS PHOTOBIOLOGICAL SAFETY OF LAMPS AND LAMPSYSTEM METHODOLOGY AND HUMAN EXPOSURE TO RADIO FREQUENCY FIELDS FROM HAND-HELD AND BODY-MOUNTED WIRELESS DEVICES. HUMAN MODELS, COMMUNICATION INSTRUMENTATION, AND PROCEDURES. PROCEDURE TO DETERMINE THE SPECIFIC ABSORPTION RATE
(SAR) FOR HAND-HELD DEVICES USED IN CLOSE PROXIMITY TO THE EAR (FREQUENCY RANGE OF 300 MHZ TO 3 GHZ) HUMAN EXPOSURE TO RADIO FREQUENCY FIELDS FROM HAND-HELD AND BODY-MOUNTED WIRELESS DEVICES. HUMAN MODELS, COMMUNICATION INSTRUMENTATION, AND PROCEDURES. PROCEDURE TO DETERMINE THE SPECIFIC ABSORPTION RATE
(SAR) FOR WIRELESS COMMUNICATION DEVICES USED IN CLOSE PROXIMITY TO THE HUMAN BODY
(FREQUENCY RANGE OF 30 MHZ TO 6 GHZ) Ruggero Cacioppo Quality & Reliability Manager - Europe Datalogic ADC s.r.l. ETSI EN 300 328 V 1.7.1 :2006 EN 60950-1:2006
+A11 :2009 +A1 :2010 +A12 :2011 IEC 60950-1:2005
+A1 :2009 EN 50332-2 :2003 IEC 60825-1 :2007 IEC 62471 :2006 EN 62471 :2008 EN 62209-1 : 2006 EN 62209-2 :2010 Lippo di Calderara, September 5, 2012 Datalogic ADC s.r.l. Via S. Vitalino 13 40012 Calderara di Reno Bologna - Italy 12 dichiara che declares that the dclare que le bescheinigt ,da das Gert declare que el LYNX modelli con funzionalit radio Edge+BT+802.11b/g/n models with Edge+BT+802.11b/g/n radio feature modles avec Edge+BT+802.11b/g/n radio intgrs modelle mit Edge+BT+802.11b/g/n radio-funktionalitt modelos con funcionalidad radio Edge+BT+802.11b/g/n sono conformi alle Direttive del Consiglio Europeo sottoelencate:
are in conformity with the requirements of the European Council Directives listed below sont conformes aux spcifications des Directives de lUnion Europenne ci-dessous:
der nachstehend angefhrten Direktiven des Europischen Rats:
cumple con los requisitos de las Directivas del Consejo Europeo, segn la lista siguiente:
2004/108 and 1999/5/EEC R&TTE Questa dichiarazione basata sulla conformit dei prodotti alle norme seguenti:
This declaration is based upon compliance of the products to the following standards:
Cette dclaration repose sur la conformit des produits aux normes suivantes:
Diese Erklrung basiert darauf, da das Produkt den folgenden Normen entspricht:
Esta declaracin se basa en el cumplimiento de los productos con la siguientes normas:
EN 55022:2010 INFORMATION TECHNOLOGY EQUIPMENT RADIO DISTURBANCE CHARACTERISTICS LIMITS AND METHODS OF MEASUREMENTS INFORMATION TECHNOLOGY EQUIPMENT IMMUNITY CHARACTERISTICS LIMITS AND METHODS OF MEASUREMENT ELECTROMAGNETIC COMPATIBILITY AND RADIO
(ERM); ELECTROMAGNETIC SPECTRUM MATTERS FOR RADIO COMPATIBILITY EQUIPMENT AND SERVICES; PART1: COMMON TECHNICAL REQUIREMENTS ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS
(ERM);ELECTROMAGNETIC COMPATIBILITY
(EMC) STANDARD FOR RADIO EQUIPMENT AND SERVICES;PART 3: SPECIFIC CONDITIONS FOR SHORT-RANGE DEVICES (SRD) OPERATING ON FREQUENCIES BETWEEN 9 KHZ AND 40 GHZ
(EMC) STANDARD EN 55024: 2010 ETSI EN 301 489-1 V1.9.2 : 2011 ETSI EN 301 489-3 V1.4.1 :2002 ETSI EN 301 489-7 V1.3.1 :2005 ETSI EN 301 489-17 V2.1.1:2009 ETSI EN 301 489-24 V1.5.1 :2010 ETSI EN 301 511 V9.0.2 :2003 ETSI EN 301 908-1 V5.2.1 :2011 ETSI EN 301 908-2 V5.2.1 :2011 ETSI EN 300 328 V1.7.1 :2006 ETSI EN 300 440-2 V1.4.1 : 2010 EN 60950-1:2006
+A11 :2009 +A1 :2010 +A12 :2011 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); ELECTROMAGNETIC COMPATIBILITY
(EMC) STANDARD FOR RADIO EQUIPMENT AND SERVICES; PART 7: SPECIFIC CONDITIONS FOR MOBILE AND PORTABLE RADIO AND ANCILLARY EQUIPMENT OF DIGITAL CELLULAR RADIO TELECOMMUNICATIONS SYSTEMS (GSM AND DCS) ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); ELECTROMAGNETIC COMPATIBILITY
(EMC) STANDARD FOR RADIO EQUIPMENT; PART 17: SPECIFIC CONDITIONS FOR 2,4 GHZ WIDEBAND TRANSMISSION SYSTEMS, 5 GHZ HIGH PERFORMANCE RLAN EQUIPMENT AND 5,8 GHZ BROADBAND DATA TRANSMITTING SYSTEMS ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS
(ERM);ELECTROMAGNETIC COMPATIBILITY
(EMC) STANDARD FOR RADIO EQUIPMENT AND SERVICES;PART 24: SPECIFIC CONDITIONS FOR IMT-2000 CDMA DIRECT SPREAD
(UTRA) FOR MOBILE AND PORTABLE (UE) RADIO AND ANCILLARY EQUIPMENT THIRD-GENERATION GLOBAL SYSTEM FOR MOBILE COMMUNICATIONS
(GSM);HARMONIZED EN FOR MOBILE STATIONS IN THE GSM 900 AND GSM 1800 BANDS COVERING ESSENTIAL REQUIREMENTS UNDER ARTICLE 3.2 OF THE R&TTE DIRECTIVE (1999/5/EC) ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM);BASE STATIONS (BS), REPEATERS AND USER EQUIPMENT (UE) FOR IMT-
2000 CELLULAR NETWORKS;PART 1: HARMONIZED EN FOR IMT-
2000, INTRODUCTION AND COMMON REQUIREMENTS, COVERING THE ESSENTIAL REQUIREMENTS OF ARTICLE 3.2 OF THE R&TTE DIRECTIVE IMT CELLULAR NETWORKS;
HARMONIZED EN COVERING THE ESSENTIAL REQUIREMENTS OF ARTICLE 3.2 OF THE R&TTE DIRECTIVE; PART 2: CDMA DIRECT SPREAD (UTRA FDD) USER EQUIPMENT (UE) ELECTROMAGNETIC COMPATIBILITY AND RADIO
(ERM); WIDEBAND SPECTRUM MATTERS TRANSMISSION SYSTEMS; DATA TRANSMISSION EQUIPMENT OPERATING IN THE 2,4GHZ ISM BAND AND USING WIDE BAND MODULATION TECHNIQUES;
HARMONIZED ESSENTIAL REQUIREMENTS UNDER ARTICLE 3.2 OF THE R&TTE DIRECTIVE ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS
(ERM); SHORT RANGE DEVICES; RADIO EQUIPMENT TO BE USED IN THE 1 GHZ TO 40 GHZ FREQUENCY RANGE; PART 2:
HARMONIZED EN UNDER ARTICLE 3.2 OF THE R&TTE DIRECTIVE INFORMATION TECHNOLOGY EQUIPMENT - SAFETY -
PART 1 : GENERAL REQUIREMENTS COVERING EN AND AND LAMPS SAFETY OF METHODOLOGY INFORMATION TECHNOLOGY EQUIPMENT - SAFETY -
PART 1 : GENERAL REQUIREMENTS SOUND SYSTEM EQUIPMENT - HEADPHONES AND EARPHONES ASSOCIATED WITH PORTABLE AUDIO EQUIPMENT - MAXIMUM SOUND PRESSURE LEVEL MEASUREMENT LIMIT CONSIDERATIONS - PART 2: MATCHING OF SETS WITH HEADPHONES IF EITHER OR BOTH ARE OFFERED SEPARATELY SAFETY OF LASER PRODUCTS - PART 1: EQUIPMENT CLASSIFICATION AND REQUIREMENTS PHOTOBIOLOGICAL LAMPSYSTEM PRODUCT STANDARD TO DEMONSTRATE THE COMPLIANCE OF MOBILE PHONES WITH THE BASIC RESTRICTIONS RELATED TO HUMAN EXPOSURE TO ELECTROMAGNETIC FIELDS ( 300MHZ - 3GHZ ) HUMAN EXPOSURE TO RADIO FREQUENCY FIELDS FROM HAND-HELD AND BODY-MOUNTED WIRELESS COMMUNICATION DEVICES. HUMAN MODELS, INSTRUMENTATION, PROCEDURES. PROCEDURE TO DETERMINE THE SPECIFIC
(SAR) FOR HAND-HELD ABSORPTION RATE DEVICES USED IN CLOSE PROXIMITY TO THE EAR
(FREQUENCY RANGE OF 300 MHZ TO 3 GHZ) HUMAN EXPOSURE TO RADIO FREQUENCY FIELDS FROM HAND-HELD AND BODY-MOUNTED WIRELESS COMMUNICATION DEVICES. HUMAN MODELS, INSTRUMENTATION, PROCEDURES. PROCEDURE TO DETERMINE THE SPECIFIC FOR WIRELESS ABSORPTION RATE COMMUNICATION DEVICES USED IN CLOSE PROXIMITY TO THE HUMAN BODY (FREQUENCY RANGE OF 30 MHZ TO 6 GHZ)
(SAR) AND AND Ruggero Cacioppo Quality & Reliability Manager - Europe Datalogic ADC s.r.l. IEC 60950-1:2005
+A1 :2009 EN 50332-2 :2003 IEC 60825-1 :2007 IEC 62471 :2006 EN 62471 :2008 EN 50360 :2001 EN 62209-1 : 2006 EN 62209-2 :2010 Lippo di Calderara, September 5, 2012
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2012-10-31 | 2412 ~ 2462 | DTS - Digital Transmission System | Original Equipment |
2 | 2012-10-30 | JBP - Part 15 Class B Computing Device Peripheral | ||
3 | 2402 ~ 2480 | DSS - Part 15 Spread Spectrum Transmitter |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 2 3 | Effective |
2012-10-31
|
||||
1 2 3 |
2012-10-30
|
|||||
1 2 3 | Applicant's complete, legal business name |
Datalogic S.r.l.
|
||||
1 2 3 | FCC Registration Number (FRN) |
0016179699
|
||||
1 2 3 | Physical Address |
Via S. Vitalino 13
|
||||
1 2 3 |
Calderara di Reno, N/A 40012
|
|||||
1 2 3 |
Italy
|
|||||
app s | TCB Information | |||||
1 2 3 | TCB Application Email Address |
k******@emcc.de
|
||||
1 2 3 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
1 2 3 |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
|||||
app s | FCC ID | |||||
1 2 3 | Grantee Code |
U4G
|
||||
1 2 3 | Equipment Product Code |
0073
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 2 3 | Name |
R******** C********
|
||||
1 2 3 | Title |
Product Quality Leader
|
||||
1 2 3 | Telephone Number |
+39 0********
|
||||
1 2 3 | Fax Number |
+39 0********
|
||||
1 2 3 |
r******@datalogic.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 2 3 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 2 3 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 2 3 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 2 3 | Equipment Class | DTS - Digital Transmission System | ||||
1 2 3 | JBP - Part 15 Class B Computing Device Peripheral | |||||
1 2 3 | DSS - Part 15 Spread Spectrum Transmitter | |||||
1 2 3 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Mobile Computer | ||||
1 2 3 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 2 3 | Modular Equipment Type | Does not apply | ||||
1 2 3 | Purpose / Application is for | Original Equipment | ||||
1 2 3 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | Yes | ||||
1 2 3 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 2 3 | Grant Comments | Power output listed is peak conducted. This device has been approved for use in specific co-location configurations, as described in this filing. SAR compliance for body-worn operations is restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head and body-worn accessory use conditions are 0.16 W/kg and 0.15 W/kg, respectively. | ||||
1 2 3 | Power output listed is peak conducted. This device has been approved for use in specific co-location configurations, as described in this filing. | |||||
1 2 3 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 2 3 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 2 3 | Firm Name |
Korea Testing Laboratory
|
||||
1 2 3 | Name |
J****** K****
|
||||
1 2 3 |
Y**** K******
|
|||||
1 2 3 | Telephone Number |
82-2-********
|
||||
1 2 3 |
82-2-********
|
|||||
1 2 3 | Fax Number |
82-2-********
|
||||
1 2 3 |
j******@ktl.re.kr
|
|||||
1 2 3 |
k******@wm.ktl.re.kr
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | CC | 2412.00000000 | 2462.00000000 | 0.0440000 | |||||||||||||||||||||||||||||||||||
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
2 | 1 | 15B | CC | ||||||||||||||||||||||||||||||||||||||
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
3 | 1 | 15C | CC | 2402.00000000 | 2480.00000000 | 0.0010000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC