FCC ID: U4GN030 Mobile Computer

by: Datalogic S.r.l. latest update: 2016-05-31 model: N030

Four grants have been issued under this FCC ID from 02/26/2014 to 05/31/2016 (this is one of eighteen releases in 2016 for this grantee). Public details available include frequency information, internal & external photos, and manuals. some products also feature user submitted or linked password defaults, instructions, drivers, troubleshooting guides, & warrantee terms.
permalink for this FCC identifier
|
|
|   
eg for Slack usage
app s submitted / available
1 2 3 4 Users Manual (Statement) Users Manual pdf 623.31 KiB
1 2 3 4 Users Manual Users Manual pdf 334.32 KiB
1 2 3 4 Cover Letter(s) pdf
1 2 3 4 Cover Letter(s) pdf
1 2 3 4 Cover Letter(s) pdf
1 2 3 4 Attestation Statements pdf
1 2 3 4 Attestation Statements pdf
1 2 3 4 Cover Letter(s) pdf
1 2 3 4 Cover Letter(s) pdf
1 2 3 4 External Photos pdf
1 2 3 4 Internal Photos pdf
1 2 3 4 ID Label/Location Info pdf
1 2 3 4 Operational Description pdf
1 2 3 4 RF Exposure Info pdf
1 2 3 4 RF Exposure Info pdf
1 2 3 4 Test Report pdf
1 2 3 4 Test Report pdf
1 2 3 4 Test Report pdf
1 2 3 4 Test Report pdf
1 2 3 4 Test Setup Photos pdf
1 2 3 4 Test Setup Photos pdf
1 2 3 4 Users Manual (Statement) Users Manual pdf 623.31 KiB
1 2 3 4 Users Manual Users Manual pdf 334.32 KiB

frequency equipment class purpose
1 2016-05-31 5745 ~ 5825 NII - Unlicensed National Information Infrastructure TX Class II Permissive Change
2 2014-02-26 5660 ~ 5700 NII - Unlicensed National Information Infrastructure TX Original Equipment
3 5745 ~ 5825 DTS - Digital Transmission System
4 2402 ~ 2480 DSS - Part 15 Spread Spectrum Transmitter

Application Forms

app s Applicant Information
1 2 3 4 Effective 2016-05-31
1 2 3 4 2014-02-26
1 2 3 4 Applicant's complete, legal business name Datalogic S.r.l.
1 2 3 4 FCC Registration Number (FRN) 0016179699
1 2 3 4 Physical Address Via S. Vitalino 13
1 2 3 4 Calderara di Reno, N/A
1 2 3 4 Italy
app s TCB Information
1 2 3 4 TCB Application Email Address c******@telefication.com
1 2 3 4 c******@curtis-straus.com
1 2 3 4 TCB Scope A4: UNII devices & low power transmitters using spread spectrum techniques
app s FCC ID
1 2 3 4 Grantee Code U4G
1 2 3 4 Equipment Product Code N030
app s Person at the applicant's address to receive grant or for contact
1 2 3 4 Name R******** C****
1 2 3 4 Title Product Quality Leader
1 2 3 4 Telephone Number +39 0********
1 2 3 4 Fax Number +39 0********
1 2 3 4 E-mail r******@datalogic.com
app s Technical Contact
1 2 3 4 Firm Name International Certification Corp.
1 2 3 4 Name G****** C******
1 2 3 4 Physical Address No.3-1, Lane 6, Wen San 3rd St. Kwei Shan
1 2 3 4 Taiwan
1 2 3 4 Telephone Number 886-3********
1 2 3 4 Fax Number 886-3********
1 2 3 4 E-mail G******@icertifi.com.tw
app s Non Technical Contact
1 2 3 4 Firm Name International Certification Corp.
1 2 3 4 Name W******** L******
1 2 3 4 Physical Address No.3-1, Lane 6, Wen San 3rd St. Kwei Shan
1 2 3 4 Taiwan
1 2 3 4 Telephone Number 886-3********
1 2 3 4 Fax Number 886-3********
1 2 3 4 E-mail w******@icertifi.com.tw
app s Confidentiality (long or short term)
1 2 3 4 Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?:Yes
1 2 3 4 Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?:No
if no date is supplied, the release date will be set to 45 calendar days past the date of grant.
app s Cognitive Radio & Software Defined Radio, Class, etc
1 2 3 4 Is this application for software defined/cognitive radio authorization?No
1 2 3 4 Equipment ClassNII - Unlicensed National Information Infrastructure TX
1 2 3 4 DTS - Digital Transmission System
1 2 3 4 DSS - Part 15 Spread Spectrum Transmitter
1 2 3 4 Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant)Mobile Computer
1 2 3 4 Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application?No
1 2 3 4 Modular Equipment TypeDoes not apply
1 2 3 4 Purpose / Application is forClass II Permissive Change
1 2 3 4 Original Equipment
1 2 3 4 Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization?Yes
1 2 3 4 Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization?No
1 2 3 4 Grant CommentsCIIPC: This change to accomodate for UNII Bands to comply with the new rules. Power listed is conducted. SAR compliance has been demonstrated as described in this filing, body-worn operating configurations is limited to the belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device and the user's body. The antenna(s) used for this transmitter must not be collocated or operating in conjunction with any other antenna or transmitter, except as evaluated in this filing. End-users must be provided with specific operating instructions for satisfying RF exposure compliance requirements. The highest reported SAR value for head, body-worn and simultaneous use conditions are 0.19 W/kg, <0.1 W/kg and 0.24 W/kg, respectively. Operations in the 5.15-5.25GHz band are restricted to indoor usage only. This device complies with the Dynamic Frequency Selection (DFS) requirements of Report and Order FCC 03-287 as a Client only without Radar Detection.
1 2 3 4 Power listed is conducted. SAR compliance has been demonstrated as described in this filing, body-worn operating configurations is limited to the belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device and the user's body. The antenna(s) used for this transmitter must not be collocated or operating in conjunction with any other antenna or transmitter, except as evaluated in this filing. End-users must be provided with specific operating instructions for satisfying RF exposure compliance requirements. The highest reported SAR value for head, body-worn and simultaneous use conditions are 0.19 W/kg, <0.1 W/kg and 0.24 W/kg, respectively. Operations in the 5.15-5.25GHz band are restricted to indoor usage only. This device complies with the Dynamic Frequency Selection (DFS) requirements of Report and Order FCC 03-287 as a Client only without Radar Detection.
1 2 3 4 Power listed is conducted. SAR compliance has been demonstrated as described in this filing, body-worn operating configurations is limited to the belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device and the user's body. The antenna(s) used for this transmitter must not be collocated or operating in conjunction with any other antenna or transmitter, except as evaluated in this filing. End-users must be provided with specific operating instructions for satisfying RF exposure compliance requirements. The highest reported SAR value for head, body-worn and simultaneous use conditions are <0.1 W/kg, <0.1 W/kg and <0.1 W/kg, respectively.
1 2 3 4 Power listed is conducted. The antenna(s) used for this transmitter must not be collocated or operating in conjunction with any other antenna or transmitter, except as evaluated in this filing. End-users must be provided with specific operating instructions for satisfying RF exposure compliance requirements.
1 2 3 4 Is there an equipment authorization waiver associated with this application?No
1 2 3 4 If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded?No
app s Test Firm Name and Contact Information
1 2 3 4 Firm Name International Certification Corp.
1 2 3 4 Bureau Veritas CPS (H.K.) Ltd., Taoyuan Branch
1 2 3 4 Name F**** C****
1 2 3 4 R****** C****
1 2 3 4 Telephone Number 886-3******** Extension:
1 2 3 4 +886-******** Extension:
1 2 3 4 Fax Number 886-3********
1 2 3 4 +886-********
1 2 3 4 E-mail J******@icertifi.com.tw
1 2 3 4 r******@tw.bureauveritas.com
Equipment Specifications
Line Rule Parts Grant Notes Lower Frequency Upper Frequency Power Output Tolerance Emission Designator Microprocessor Number
1 1 15E 20 28 38 CC 5180 5240 0.043
1 2 15E 20 28 38 CC ND 5260 5320 0.058
1 3 15E 20 28 38 CC ND 5500 5580 0.029
1 4 15E 20 28 38 CC ND 5660 5700 0.016
1 5 15E 20 28 38 49 CC 5745 5825 0.035
Line Rule Parts Grant Notes Lower Frequency Upper Frequency Power Output Tolerance Emission Designator Microprocessor Number
2 1 15E 20 28 CC 5180 5240 0.043
2 2 15E 20 28 CC ND 5260 5320 0.058
2 3 15E 20 28 CC ND 5500 5580 0.029
2 4 15E 20 28 CC ND 5660 5700 0.016
Line Rule Parts Grant Notes Lower Frequency Upper Frequency Power Output Tolerance Emission Designator Microprocessor Number
3 1 15C 20 28 CC 2412 2462 0.202
3 2 15C 20 28 CC 5745 5825 0.035
Line Rule Parts Grant Notes Lower Frequency Upper Frequency Power Output Tolerance Emission Designator Microprocessor Number
4 1 15C 20 28 CC 2402.00000000 2480.00000000 0.0040000

 

some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details

 

  This product uses the FCC Data API but is not endorsed or certified by the FCC