all | frequencies |
|
|
exhibits | applications |
---|---|---|---|---|---|
manuals |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 2 |
|
Users Manual 1 | Users Manual | 1.82 MiB | / June 02 2010 | |||
1 2 |
|
Users Manual Addendum | Users Manual | 29.20 KiB | / June 02 2010 | |||
1 2 | Cover Letter(s) | |||||||
1 2 | Cover Letter(s) | |||||||
1 2 | Cover Letter(s) | |||||||
1 2 | External Photos | / June 02 2010 | ||||||
1 2 | Internal Photos | / June 02 2010 | ||||||
1 2 | ID Label/Location Info | |||||||
1 2 | ID Label/Location Info | |||||||
1 2 | Cover Letter(s) | |||||||
1 2 | RF Exposure Info | |||||||
1 2 | RF Exposure Info | |||||||
1 2 | RF Exposure Info | |||||||
1 2 | RF Exposure Info | |||||||
1 2 | Test Setup Photos | / June 02 2010 | ||||||
1 2 | Cover Letter(s) | |||||||
1 2 | Test Report | |||||||
1 2 | Test Setup Photos | / June 02 2010 |
1 2 | Users Manual 1 | Users Manual | 1.82 MiB | / June 02 2010 |
Datalogic Mobile S.r.l. Via S. Vitalino 13 40012 - Lippo di Calderara di Reno Bologna - Italy Datalogic Memor - User's Manual Software Version: 4.00 Ed.: 05/2009 ALL RIGHTS RESERVED The Datalogic name and logo are registered trademarks of Datalogic S.p.A. in many countries. The Memor name is a trademark of Datalogic Mobile S.r.l. All other brand and product names mentioned herein are for identification purposes only and may be trademarks or registered trademarks of their respective owners. Datalogic reserves the right to make modifications and improvements without prior notification. Datalogic shall not be liable for technical or editorial errors or omissions contained herein, nor for incidental or consequential damages resulting from the use of this material. 2008-2009 Datalogic Mobile S.r.l. All rights reserved. Protected to the fullest extent under U.S. and international laws. Copying, or altering of this document is prohibited without express written consent from Datalogic Mobile S.r.l. CONTENTS REFERENCES.....................................................................................v Conventions .........................................................................................v Reference Documentation ...................................................................v Services and Support...........................................................................v SAFETY REGULATIONS ...................................................................vi General Safety Rules ..........................................................................vi Power Supply ......................................................................................vi Laser Safety ....................................................................................... vii LED Class ......................................................................................... xiii Radio Compliance............................................................................. xiii FCC Compliance................................................................................xv Industry Canada Compliance........................................................... xvii SAR Compliance............................................................................. xviii Patents ............................................................................................ xviii WEEE Compliance............................................................................ xix China RoHS Pollution Control Logos ................................................ xxi GENERAL VIEW............................................................................. xxii INTRODUCTION................................................................................. 1 Datalogic Memor Description .......................................................... 1 Models Description.............................................................................. 2 Package Contents............................................................................... 4 Inserting a Micro SD Card................................................................... 5 Installing the SIM Card........................................................................ 7 Removing the SIM Card...................................................................... 9 Accessories....................................................................................... 10 Operating System.............................................................................. 10 CONNECTIONS................................................................................ 11 USB Connection................................................................................ 11 Connection to USB peripherals......................................................... 13 RS232 Connection ............................................................................ 15 WLAN Connection............................................................................. 16 WPAN Connection ............................................................................ 18 WWAN Connection ........................................................................... 19 Connection Cables............................................................................ 21 Wireless and Radio Frequencies Warnings ...................................... 22 USE AND FUNCTIONING ................................................................ 24 Startup............................................................................................... 24 Using the Stylus ................................................................................ 26 Using the Joystick ............................................................................. 27 Windows Mobile Welcome Wizard.................................................... 28 Data Capture..................................................................................... 29 Laser Data Capture........................................................................... 29 Imager Data Capture......................................................................... 30 Description of the Keys ..................................................................... 32 1 1.1 1.2 1.3 1.4 1.5 1.5.1 1.6 1.7 2 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 3 3.1 3.1.1 3.1.2 3.2 3.3 3.3.1 3.3.2 3.4 iii Resetting the Memor ..................................................................... 34 3.4.1 Status Indicators ............................................................................... 37 3.5 LED Status ........................................................................................ 37 3.5.1 Taskbar ............................................................................................. 38 3.5.2 Data Capture Configuration............................................................... 40 3.6 Configure........................................................................................... 40 3.6.1 Capture.............................................................................................. 45 3.6.2 Control Panel .................................................................................... 46 3.7 Buttons .............................................................................................. 47 3.7.1 3.7.2 Registry ............................................................................................. 48 Files Admin ....................................................................................... 49 3.7.3 3.7.4 Wireless Communications................................................................. 51 3.7.5 Stylus Calibration .............................................................................. 53 Volume Settings ................................................................................ 56 3.7.6 Windows Connections....................................................................... 60 3.8 3.8.1 Microsoft ActiveSync.................................................................... 60 3.8.2 Bluetooth Manager Device Setup................................................... 62 3.8.3 Windows Mobile Phone..................................................................... 71 FTP Server Setup.............................................................................. 72 3.8.4 3.9 Backup Directory File Management .................................................. 73 Firmware Update............................................................................... 73 3.10 4 MAINTENANCE................................................................................ 74 Charging the Battery Pack ................................................................ 74 4.1 Replacing the Battery Pack............................................................... 76 4.2 Cleaning the Mobile Computer.......................................................... 80 4.3 5 TECHNICAL FEATURES ................................................................. 81 5.1 Technical Data .................................................................................. 81 Reading Diagram .............................................................................. 84 5.2 TEST CODES ................................................................................... 85 6 GLOSSARY ...................................................................................... 89 INDEX ............................................................................................... 91 iv REFERENCES CONVENTIONS This manual uses the following conventions:
User refers to anyone using a Datalogic Memor mobile computer. Mobile computer and "Datalogic Memor" refer to Datalogic Memor mobile computer. You refers to the System Administrator or Technical Support person using this manual to install, configure, operate, maintain or troubleshoot a Datalogic Memor mobile computer. Single Cradle refers to the Datalogic Memor Single Cradle. REFERENCE DOCUMENTATION For further information regarding Datalogic Memor refer to the SDK Help on-Line. SERVICES AND SUPPORT Datalogic provides several services as well as technical support through its website. Log on to www.mobile.datalogic.com and click on the links indicated for further information including:
PRODUCTS Search through the links to arrive at your product page where you can download specific Manuals and Software & Utilities
SERVICES & SUPPORT
Datalogic Services Warranty Extensions and Maintenance Agreements Authorised Repair Centres
CONTACT US E-mail form and listing of Datalogic Subsidiaries v SAFETY REGULATIONS Read this manual carefully before performing any type of connection to the Datalogic Memor mobile computer. The user is responsible for any damages caused by incorrect use of the equipment or by inobservance of the indication supplied in this manual. NOTE GENERAL SAFETY RULES Use only the components supplied by the manufacturer for the specific Datalogic Memor being used. Do not attempt to disassemble the Datalogic Memor mobile computer, as it does not contain parts that can be repaired by the user. Any tampering will invalidate the warranty. When replacing the battery pack or at the end of the operative life of the Datalogic Memor mobile computer, disposal must be performed in compliance with the laws in force. Before using the devices and the battery packs, read par. 4.2. Do not submerge the Datalogic Memor in liquid products. For further information, refer to this manual and to the Datalogic Mobile web site: www.mobile.datalogic.com. POWER SUPPLY This device is intended to be connected to a UL Listed/CSA Certified computer which supplies power directly to the Datalogic Memor or else be supplied by a UL Listed/CSA Certified Power Unit marked Class 2 or LPS power source rated 5 V, 3.0 A, which supplies power directly to the Datalogic Memor via the power connector of the cable. The package includes three international plug adapters. The adapters must be plugged in the power supply before the power supply itself is plugged on the wall outlet. vi LASER SAFETY The laser light is visible to the human eye and is emitted from the window indicated in the figure. This information applies to both laser models and the Datalogic Memor Imager Aiming System. Laser output window vii I D F E La luce laser visibile all'occhio umano e viene emessa dalla finestra indicata nella figura. LUCE LASER NON FISSARE IL FASCIO APPARECCHIO LASER DI CLASSE 2 MASSIMA POTENZA DI USCITA: 1.7mW LUNGHEZZA D'ONDA EMESSA: 650nm CONFORME A EN 60825-1 (2001) Die Laserstrahlung ist fr das menschliche Auge sichtbar und wird am Strahlaustrittsfenster ausgesendet (siehe Bild). LASERSTRAHLUNG NICHT IN DER STRAHL BLINKEN PRODUKT DER LASERKLASSE 2 MAXIMALE AUSGANGLEISTUNG:
1.7mW WELLENLNGE:
650nm ENTSPR. EN 60825-1
(2001) Le rayon laser est visible l'oeil nu et il est mis par la fentre dsigne sur l'illustration dans la figure. La luz lser es visible al ojo humano y es emitida por la ventana indicada en la figura. RAYON LASER EVITER DE REGARDER LE RAYON APPAREIL LASER DE CLASSE 2 MAXIMUM PUISSANCE DE SORTIE: 1.7mW LONGUER D'ONDE EMISE: 650nm CONFORME A EN 60825-1 (2001) RAYO LSER NO MIRAR FIJO EL RAYO APARATO LSER DE CLASE 2 MXIMA POTENCIA DE SALIDA: 1.7mW LONGITUD DE ONDA EMITIDA: 650nm CONFORME A EN 60825-1
(2001) viii ENGLISH The following information is provided to comply with the rules imposed by international authorities and refers to the correct use of your mobile computer. STANDARD LASER SAFETY REGULATIONS This product conforms to the applicable requirements of both CDRH 21 CFR 1040 Subchapter J and EN 60825-1:2001 at the date of manufacture. For installation, use and maintenance, it is not necessary to open the device. Do not attempt to open or otherwise service any components in the optics cavity. Opening or servicing any part of the optics cavity by unauthorized personnel may violate laser safety regulations. The optics system is a factory only repair item. Use of controls or adjustments or performance of procedures other than those specified herein may result in exposure to hazardous visible laser light. CAUTION CAUTION The product utilizes a low-power laser diode. Although staring directly at the laser beam momentarily causes no known biological damage, avoid staring at the beam as one would with any very strong light source, such as the sun. Avoid that the laser beam hits the eye of an observer, even through reflective surfaces such as mirrors, etc. CAUTION Use of optical systems with the scanner will increase eye hazard. Optical binoculars, microscopes, eye glasses and magnifying glasses. instruments include ITALIANO informazioni vengono fornite dietro direttive delle autorit Le seguenti internazionali e si riferiscono alluso corretto del terminale. NORMATIVE STANDARD PER LA SICUREZZA LASER Questo prodotto risulta conforme alle normative vigenti sulla sicurezza laser alla data di produzione: CDRH 21 CFR 1040 sezione J e EN 60825-1:2001. Non si rende mai necessario aprire lapparecchio per motivi di installazione, utilizzo o manutenzione. ix ATTENZIONE Non tentare di accedere allo scomparto contenete i componenti ottici o di farne la manutenzione. Lapertura dello scomparto, o la manutenzione di qualsiasi parte ottica da parte di personale non autorizzato, potrebbe violare le norme della sicurezza. Il sistema ottico pu essere riparato solamente alla fabbrica. L'utilizzo di procedure o regolazioni differenti da quelle descritte provocare un'esposizione pericolosa a luce laser visibile. documentazione nella pu ATTENZIONE Il prodotto utilizza un diodo laser a bassa potenza. Sebbene non siano noti danni riportati dallocchio umano in seguito ad una esposizione di breve durata, evitare di fissare il raggio laser cos come si eviterebbe qualsiasi altra sorgente di luminosit intensa, ad esempio il sole. Evitare inoltre di dirigere il raggio laser negli occhi di un osservatore, anche attraverso superfici riflettenti come gli specchi. ATTENZIONE Luso di strumenti ottici assieme allo scanner pu aumentare il pericolo di danno agli occhi. Tali strumenti ottici includono cannocchiali, microscopi, occhiali e lenti di ingrandimento. DEUTSCH Die folgenden Informationen stimmen mit den Sicherheitshinweisen berein, die von internationalen Behrden auferlegt wurden, und sie beziehen sich auf den korrekten Gebrauch vom Terminal. NORM FR DIE LASERSICHERHEIT Dies Produkt entspricht am Tag der Herstellung den gltigen EN 60825-1:2001 und CDRH 21 CFR 1040 Subchapter J Normen fr die Lasersicherheit. Es ist nicht notwendig, das Gert wegen Betrieb oder Installations-, und Wartungs-Arbeiten zu ffnen. ACHTUNG Unter keinen Umstnden darf versucht werden, die Komponenten im Optikhohlraum zu ffnen oder auf irgendwelche andere Weise zu warten. Das ffnen bzw. im Optikhohlraum durch Warten der Komponenten unbefugtes Personal verstt gegen die Laser-
Sicherheitsbestimmungen. Das Optiksystem darf nur werkseitig repariert werden. x Jegliche nderungen am Gert sowie Vorgehensweisen, die nicht in dieser Betriebsanleitung beschrieben werden, knnen ein gefhrliches Laserlicht verursachen. ACHTUNG Der Produkt benutzt eine Laserdiode. Obwohl zur Zeit keine Augenschden von kurzen Einstrahlungen bekannt sind, sollten Sie es vermeiden fr lngere Zeit in den Laserstrahl zu schauen, genauso wenig wie in starke Lichtquellen (z.B. die Sonne). Vermeiden Sie es, den Laserstrahl weder gegen die Augen eines Beobachters, noch gegen reflektierende Oberflchen zu richten. ACHTUNG Die Verwendung von Optiksystemen mit diesem Scanner erhht die Gefahr einer Augenbeschdigung. Zu optischen Instrumenten gehren unter anderem Fernglser, Mikroskope, Brillen und Vergrerungsglser. FRANAIS Les informations suivantes sont fournies selon les rgles fixes par les autorits internationales et se rfrent une correcte utilisation du terminal. NORMES DE SECURITE LASER Ce produit est conforme aux normes de scurit laser en vigueur sa date de fabrication: CDRH 21 CFR 1040 sous-chapitre J et EN 60825-1:2001. Il nest pas ncessaire douvrir lappareil pour linstallation, lutilisation ou lentretien. Ne pas essayer douvrir ou de rparer les composants de la cavit optique. Louverture de la cavit optique ou la rparation de ses composants par une personne non qualifie peut entraner le nonrespect des rgles de scurit relatives au laser. Le systme optique ne peut tre rpar quen usine. L'utilisation de procdures ou rglages diffrents de ceux donns ici peut entraner une dangereuse exposition lumire laser visible. ATTENTION ATTENTION Le produit utilise une diode laser. Aucun dommage aux yeux humains na t constat la suite dune exposition au rayon laser. Eviter de regarder fixement le rayon, comme toute autre source lumineuse intense telle que le soleil. Eviter aussi de diriger le rayon vers les yeux dun observateur, mme travers des surfaces rflchissantes (miroirs, par exemple). xi ATTENTION Lutilisation dinstruments optiques avec le scanneur augmente le danger pour les yeux. Les instruments optiques comprennent les jumelles, les microscopes, les lunettes et les verres grossissants. ESPAOL Las informaciones siguientes son presentadas en conformidad con las disposiciones de las autoridades internacionales y se refieren al uso correcto del terminal. NORMATIVAS ESTNDAR PARA LA SEGURIDAD LSER Este aparato resulta conforme a las normativas vigentes de seguridad lser a la fecha de produccin: CDRH 21 CFR 1040 Seccin J y EN 60825-1:2001. No es necesario abrir el aparato para la instalacin, la utilizacin o la manutencin. No intente abrir o de ninguna manera dar servicio a ninguno de los componentes del receptculo ptico. Abrir o dar servicio a las piezas del receptculo ptico por parte del personal no autorizado podra ser una violacin a los reglamentos de seguridad. El sistema ptico se puede reparar en la fbrica solamente. La utilizacin de procedimientos o regulaciones diferentes de aquellas describidas en la documentacin puede causar una exposicin peligrosa a la luz lser visible. ATENCIN ATENCIN El aparato utiliza un diodo lser a baja potencia. No son notorios daos a los ojos humanos a consecuencia de una exposicin de corta duracin. Eviten de mirar fijo el rayo lser as como evitaran cualquiera otra fuente de luminosidad intensa, por ejemplo el sol. Adems, eviten de dirigir el rayo lser hacia los ojos de un observador, tambin a travs de superficies reflectantes como los espejos. El uso de sistemas pticos con el escner aumentar el riesgo de daos oculares. Los instrumentos pticos incluyen binoculares, microscopios, lentes y lupas. ATENCIN xii PRODUIT LED DE CLASSE 1 IEC PRODUCTO LED DE CLASE 1 IEC LUCE LED NON OSSERVARE DIRETTAMENTE CON STRUMENTI OTTICI APPARECCHIO LED DI CLASSE 1M LUZ LED NO OBSERVAR DIRECTAMENTE CON INSTRUMENTOS PTICOS. PRODUCTO LED DE CLASE 1M LED CLASS According to EN60825-1:2001, the Datalogic Memor 1D models which use the green spot LED are also CLASS 1 LED PRODUCTS. APPARECCHIO LED CLASSE 1 IEC PRODUKT LED KLASSE 1 IEC According to EN60825-1:2001, the Datalogic Memor 2D models which use the illuminator LED are also CLASS 1M LED PRODUCTS. LED LIGHT DO NOT VIEW DIRECTLY WITH OPTICAL INSTRUMENTS CLASS 1M LED PRODUCT LAMPE LED NE PAS OBSERVER DIRECTEMENT AVEC INSTRUMENTS OPTIQUES APPAREIL LED DE CLASSE 1M LED-LICHT. NICHT DIREKT MIT OPTISCHEN INSTRUMENTEN BETRACHTEN. GERTEKLASSE 1M. RADIO COMPLIANCE In radio systems configured with mobile computers and access points, the frequencies to be used must be allowed by the spectrum authorities of the specific country in which the installation takes place. Be absolutely sure that the system frequencies are correctly set to be compliant with the spectrum requirements of the country. The Radio modules used in this product automatically adapt to the frequencies set by the system and do not require any parameter settings. The following shows the correspondence between the Datalogic Memor models and the Radio components:
DL-MEMOR P/N: 944201019/ DL-MEMOR P/N: 944201022/
DL-MEMOR P/N: 944201014/ DL-MEMOR P/N: 944201015
DL-MEMOR P/N: 944201017/DL-MEMOR P/N: 944201018 xiii Information for the User ENGLISH Contact the competent authority responsible for the management of radio frequency devices of your country to verify any possible restrictions or licenses required. Refer to the web site http://europa.eu.int/comm/enterprise/rtte/spectr.htm for further information. ITALIANO Prendi contatto con l'autorit competente per la gestione degli apparati a radio frequenza del tuo paese, per verificare eventuali restrizioni o licenze. Ulteriori informazioni sono disponibili sul sito:
http://europa.eu.int/comm/enterprise/rtte/spectr.htm. FRANAIS Contactez l'autorit comptente en la gestion des appareils radio frquence de votre pays pour vrifier d'ventuelles restrictions ou licences. Pour tout renseignement vous pouvez vous adresser au site web:
http://europa.eu.int/comm/enterprise/rtte/spectr.htm. DEUTSCH Wenden Sie sich an die fr Radiofrequenzgerte zustndige Behrde Ihres Landes, um zu prfen ob es Einschrnkungen gibt, oder eine Lizenz erforderlich ist. Weitere Informationen finden Sie auf der Web Seite:
http://europa.eu.int/comm/enterprise/rtte/spectr.htm. ESPAOL Contacta la autoridad competente para la gestin de los dispositivos de radio frecuencia de tu pas, para verificar cualesquiera restricciones o licencias posibles requerida. Adems se puede encontrar mas informacin en el sitio Web:http://europa.eu.int/comm/enterprise/rtte/spectr.htm. xiv FCC COMPLIANCE FCC Regulations:
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiated radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. xv RF Exposure Information (SAR) This model device meets the governments requirements for exposure to radio waves. This device is designed and manufactured not to exceed the emission limits for exposure to radio frequency (RF) energy set by the Federal Communications Commission of the U.S. Government. The exposure standard for wireless devices employs a unit of measurement known as the Specific Absorption Rate, or SAR. The SAR limit set by the FCC is 1.6W/kg. *Tests for SAR are conducted using standard operating positions accepted by the FCC with the device transmitting at its highest certified power level in all tested frequency bands. Although the SAR is determined at the highest certified power level, the actual SAR level of the device while operating can be well below the maximum value. This is because the device is designed to operate at multiple power levels so as to use only the poser required to reach the network. In general, the closer you are to a wireless base station antenna, the lower the power output. The highest SAR value for the model device as reported to the FCC when tested for use at the head is 0.029 W/kg and when worn on the body, as described in this user guide, is 0.00412 W/kg (Body-worn measurements differ among device models, depending upon available enhancements and FCC requirements.) While there may be differences between the SAR levels of various devices and at various positions, they all meet the government requirement. The FCC has granted an Equipment Authorization for this model device with all reported SAR levels evaluated as in compliance with the FCC RF exposure guidelines. SAR information on this model device is on file with the FCC and can be found under the Display Grant section of http://www.fcc.gov/oet/fccid after searching on the below FCC ID:
FCC ID: U4G0030 for DL-Memor+802.11g+BT models. This device is compliant with SAR for general population /uncontrolled exposure limits in ANSI/IEEE C95.1-1999 and had been tested in accordance with the measurement methods and procedures specified in OET Bulletin 65 Supplement C. For body worn operation, this device has been tested and meets the FCC RF exposure guidelines for use with an accessory that contains no metal and the positions the handset a minimum of 1.5 cm from the body. Use of other enhancements may not ensure compliance with FCC RF exposure guidelines. If you do not use a body-worn accessory and are not holding the device at the ear, position the handset a minimum of 1.5 cm from your body when the device is switched on. xvi INDUSTRY CANADA COMPLIANCE Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numrique de la classe B est conforme la norme NMB-003 du Canada. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter. The County Code Selection feature is disabled for products marketed in the US/Canada. IMPORTANT NOTE:
IC Radiation Exposure Statement This EUT is compliant with SAR for general population/uncontrolled exposure limits in IC RSS-102 and had been tested in accordance with the measurement methods and procedures specified in IEEE 1528. This equipment should be installed and operated with minimum distance 1,5cm between the radiator &
your body. xvii SAR COMPLIANCE
This product has been tested and found to comply with the following standards:
OET BULLETIN 65 SUPPLEMENT C: evaluating compliance with FCC guidelines for human exposure to radio frequency electromagnetic fields. EN 50360:2001: product standard to demonstrate the compliance of mobile phones with the basic restrictions related to human exposure to electromagnetic fields (300 MHz 3 GHz). EN 62311:2008: assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz 300 GHz). PATENTS This product is covered by one or more of the following patents. Design Pat.: AU 310182 S; CN 658612; HK 0601962.6; KR 30-0466667; JP 1325117; TW D118829; US D574,830 S. US Pat.: 5,992,740; 6,808,114 B1; 6,997,385 B2; 7,387,246 B2. European Pat.: 681,257 B1; 789,315 B1; 1,128,315 B1; 1,396,811 B1. Additional patents pending. xviii WEEE COMPLIANCE Informazione degli utenti ai sensi della Direttiva Europea 2002/96/EC Lapparecchiatura che riporta il simbolo del bidone barrato deve essere smaltita, alla fine della sua vita utile, separatamente dai rifiuti urbani. Smaltire lapparecchiatura in conformit alla presente Direttiva consente di:
evitare possibili conseguenze negative per lambiente e per la salute umana che potrebbero invece essere causati dallerrato smaltimento dello stesso;
recuperare materiali di cui composto al fine di ottenere un importante risparmio di energia e di risorse. Per maggiori dettagli sulle modalit di smaltimento, contattare il Fornitore dal quale stata acquistata lapparecchiatura o consultare la sezione dedicata sul sito www.mobile.datalogic.com. Information for the user in accordance with the European Commission Directive 2002/96/EC At the end of its useful life, the product marked with the crossed out wheeled wastebin must be disposed of separately from urban waste. Disposing of the product according to this Directive:
avoids potentially negative consequences to the environment and human health which otherwise could be caused by incorrect disposal
enables the recovery of materials to obtain a significant savings of energy and resources. For more detailed information about disposal, contact the supplier that provided you with the product in question or consult the dedicated section at the website www.mobile.datalogic.com. Information aux utilisateurs concernant 2002/96/EC Au terme de sa vie utile, le produit qui porte le symbole d'un caisson ordures barr ne doit pas tre limin avec les dchets urbains. liminer ce produit selon cette Directive permet de:
la Directive Europenne xix
viter les retombes ngatives pour l'environnement et la sant drivant d'une limination incorrecte
rcuprer les matriaux dans le but d'une conomie importante en termes d'nergie et de ressources informations complmentaires concernant Pour obtenir des l'limination, veuillez contacter le fournisseur auprs duquel vous avez achet le produit ou consulter la section consacre au site Web www.mobile.datalogic.com. Informacin para el usuario de accuerdo con la Directiva Europea 2002/96/CE Al final de su vida til, el producto marcado con un simbolo de contenedor de bassura mvil tachado no debe eliminarse junto a los desechos urbanos. Eliminar este producto de accuerdo con la Directiva permite de:
evitar posibles consecuencias negativas para el medio ambiente y la salud derivadas de una eliminacin inadecuada
recuperar los materiales obteniendo as un ahorro importante de energa y recursos Para obtener una informacin ms detallada sobre la eliminacin, por favor, pngase en contacto con el proveedor donde lo compr o consultar la seccin dedicada en el Web site www.mobile.datalogic.com. Benutzerinformation bezglich Richtlinie 2002/96/EC der europischen Kommission Am Ende des Gertelebenszyklus darf das Produkt nicht ber den stdtischen Hausmll entsorgt werden. Eine entsprechende Mlltrennung ist erforderlich. Beseitigung des Produkts entsprechend der Richtlinie:
verhindert negative Auswirkungen fr die Umwelt und die Gesundheit
ermglicht die Wiederverwendung der Materialien und spart somit der Menschen Energie und Resourcen Weitere Informationen zu dieser Richtlinie erhalten sie von ihrem Lieferanten ber den sie das Produkt erworben haben, oder besuchen sie unsere Hompage unter www.mobile.datalogic.com. xx CHINA ROHS POLLUTION CONTROL LOGOS Toxic or Hazardous Substances and Elements for DL-MEMOR PBDE Cr6+
Pb O Hg O Cd O PBB O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O Part name Upper Case Lower Case Touch Panel PCB Board Laser Engine Imager Engine GSM Module
(Note 1) BT O O O O O O O O O O O O Module
(Note 2) 802.11b/
g Radio Module
(Note 3) O: Indicates that this is a toxic or hazardous substance contained in all of the homogenous materials for this part is below the limit requirement in SJ/T11363-2006. X: Indicates that this is toxic or hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in SJ/T11363-2006. Note 1: It is only for 944201018 Model. Note 2: It is only for 944201015, 944201019, 944201022, 944201018 Note 3: It is only for 944201015, 944201019, 944201022 Models. Note 4: 99% of the parts of this product adopt the nonpoisonous and harmless environmental protection material to make, the part with poisonous harmful substance or the element is all unable to realize the substitution of the poisonous harmful thing or the element because the global technological development level is limited. Models. xxi GENERAL VIEW D C B A F E G A) QVGA 64K Color Display B) Good Read or User Programmable LED C) Charging Status LED D) Speaker E) Scan Key F) Keyboard N N) Data Capture/Laser Output Window *
O) DC Charger Connector K I J H L M G) Microphone H) Strap with Stylus Holder I) Laser Safety Label J) Rear Speaker K) ON/OFF Power Key L) Product Label (under battery) M) Battery Cover O Q P P) Communication/Charger Connector
(through cradle) Q) Mini USB Communication Connector (through cable) Remove protective film cover before use xxii INTRODUCTION 1 INTRODUCTION 1 1.1 DATALOGIC MEMOR DESCRIPTION The newly updated Datalogic Memor mobile computer maximizes a compact and light weight form factor for ease of use and shirt pocket convenience without compromising durability. Feature introductions include the Microsoft Windows Mobile 6.1 operating system, an imaging bar code scanner, and a GSM radio with Edge. All three of these options combine to make the Memor a viable alternative for use in Field Force Automation applications. The Edge radio provides a broadband cellular connection for voice and data communication enabling real time transactions and on demand contact with field personnel. Already well accepted in Retail, Windows Mobile and 2D bar code reading capability expand the number of applications Memor tackles into the Pharmacy and emerging applications for produce traceability. The computer architecture of the Memor starts with the industry leading XScale PXA310 microprocessor. Geared for smart phone computing requirements of real time information management and communication. Memory of 128 MB RAM / 256 MB Flash is sized for running multiple simultaneous applications, for managing large databases or the use of thick applications when off-line autonomy is required. The memory storage capacity can be increased through the user accessible Micro SD Card Slot. The Memor computer architecture can be paired with one of two operating systems. Microsoft Windows CE 5.0 with Microsoft WordPad and Internet Explorer 6.0 minimizes the operating system size for faster uploads and more storage space. Microsoft Windows Mobile 6.1 reduces training requirements through common Windows interfaces and tools including Outlook, Word Mobile, Excel Mobile, PowerPoint Mobile, One Note Mobile and Internet Explorer Mobile 6.0. An open source software development kit (SDK) aids in creating applications for both of these powerful Windows operating systems and alternative environments like Java Virtual Machine. Whether communicating inside or outside the four walls, Memor provides voice and data wireless communication options to meet the business need. A GSM radio using Edge data compression provides a broadband cellular connection for real time data transactions in the field. A speaker and microphone equip the Memor to handle traditional phone calls. Inside the four walls, the Summit IEEE 802.11b/g radios optimized transmit power and receiver sensitivity result in superior range with a tailored user interface for easy configuration and consistent management. Complimented by a CCX v4 security certification from Cisco, the Memor provides infrastructure compatibility focused on enterprise requirements for encrypted communication and seamless roaming. Client side applications leverage internet protocol connections for hands-free voice picking and push to talk communications. Bluetooth Wireless Technology connects headsets, printers and other peripherals while eliminating cumbersome wires and costly replacement of broken or damaged cables. Two scanner options optimize the Memor for the application needs. A laser scanner tackles intensive applications where speed and a wide depth of field 1 1 1 DATALOGIC MEMOR to the application. Charging cradles are essential. Datalogics patented Green Spot good read feedback makes Memors laser scanner intuitive while reducing errors. The 2D scan engine option leverages picture technology to capture a wide range of Linear, Stacked, and 2D codes while also providing the flexibility to capture a signatures or drivers license. Digital image decoding software reduces failed reads due to damaged and poor quality barcodes while enabling the user to scan from almost any orientation. Durability ratings protect the computing investment against accidental drops and occasional exposure to liquids and dust. A touch color display provides an easy to read interface in a wide range of lighting conditions. The phone keyboard layout and four direction joystick increase associate efficiency. Push button battery lock provides an easy to locking mechanism for quick, no hassle battery exchanges. Rechargeable Lithium polymer batteries in two sizes customize capacity include a communication cradles for RS232 and USB. A powered vehicle dock and cigarette lighter adapter extend charging capabilities onto the road. Powered by Wavelink device maintenance and management tools makes the Memor a simple device to both deploy and maintain. Datalogic Firmware, Desktop and Configuration Utilities complete the package with unprecedented ability to customize device configuration to the use environment or process. Combined these tools streamline deployment and management activities while providing developer tools to further customize units for specific applications. 1.2 MODELS DESCRIPTION The brand new Datalogic Memor is available in different models depending on the options it is equipped with. All options are listed below:
For further details about the Datalogic Memor models refer to the web site:
http://www.mobile.datalogic.com. The currently available models are:
communication options: 802.11b/g radio, Bluetooth, GSM capture options: laser, imager compute options: O.S. version 944201016 Datalogic Memor, Batch, 128MB RAM/256MB Flash, 23-key Numeric, Std Laser with Green Spot, CE 5.0 DL-Memor+Batch+1DGS+CE5 944201019 Memor, 802.11b/g CCX V4, Bluetooth, 128MB RAM/256MB Flash, 23-key Numeric, Std Laser with Green Spot, CE 5.0 DL-Memor+802.11g+BT+1DGS+CE5 Datalogic 944201022 Memor, 802.11b/g CCX V4, Bluetooth, 128MB RAM/256MB Flash, 23-key Numeric, Std 2D Imager, CE 5.0 DL-Memor+802.11g+BT+2D+CE5 Datalogic 2 INTRODUCTION 1 944201015 Memor, 802.11b/g CCX V4, Bluetooth, 128MB RAM/256MB Flash, 23-key Numeric, Std 2D Imager, WM 6.1 DL-Memor+802.11g+BT+2D+WM6.1 Datalogic 944201018 Memor, Edge Europe, Bluetooth, 128MB RAM/256MB Flash, 23-key Numeric, Std 2D Imager, WM 6.1 DL-Memor+EdgeE+BT+2D+WM6.1 Datalogic 944201014 Memor, 802.11b/g CCX V4, Bluetooth, 128MB RAM/256MB Flash, 23-key Numeric, Std Laser with Green Spot, WM 6.1 DL-Memor+802.11g+BT+1DGS+WM6.1 Datalogic 944201017 DL-Memor+EdgeE+BT+1DGS+WM6.1 Datalogic Memor, Edge Europe, Bluetooth, 128MB RAM/256MB Flash, 23-key Numeric, Std Laser with Green Spot, WM 6.1. 3 1 1 DATALOGIC MEMOR 1.3 PACKAGE CONTENTS The Datalogic Memor package contains:
1 Datalogic Memor mobile computer 1 AC/DC power supply 1 EU plug adapter 1 AUS. Plug Adapter 1 UK Plug Adapter 1 standard Mini USB cable 1 CD-ROM Datalogic SDK 1 CD-ROM Getting Started Disk only for Windows Mobile 1 extensible stylus 1 users manual 1 rechargeable standard battery pack + cover 1 hand-strap with stylus holder 1 headset (GSM models only) 1 Windows Mobile/ CE End User License Agreement (depending on models) Any other packages will contain the accessories necessary for the Datalogic Memor connection to the host computer and to the network: the cradle, one or more connection cables. Remove all the components from their packaging; check their integrity and congruity with the packing documents. Keep the original packaging for use when sending products to the technical assistance center. Damage caused by improper packaging is not covered under the warranty. CAUTION 4 Rechargeable battery packs are not initially charged. Therefore the initial operation to perform is to charge them. See paragraph 4.1. NOTE INTRODUCTION 1 INSERTING A MICRO SD CARD 1.4 Datalogic Memor provides the possibility to add a Micro SD memory storage card. To access the Micro SD card slot and insert the card, proceed as follows:
1. Turn off the Datalogic Memor. 2. Press the latch release button and pull the latch down, as indicated in the figure below:
a. Remove the cover and the battery pack, then open the Micro SD card slot by pulling up the locking plate:
5 1 1 DATALOGIC MEMOR b. Shift the cardholder to the left and then pull it up; insert the Micro SD card with the written part upward. c. Lock the card into place by pushing the cardholder down and then shifting it to the right; pull the locking plate down. 6. Close the battery cover properly, by pressing the latch release button and pulling the latch down. To remove the Micro SD card, follow the steps above to access the SD area, and remove it from its slot. CAUTION Follow proper ESD precautions to avoid damaging the SD. Proper ESD precautions include, but are not limited to, working on an ESD mat and ensuring that the operator is properly grounded. Do not force the card. If you feel resistance, remove the card, check the orientation, and reinsert it. Do not use the Micro SD card slot for any other accessories. 6 INTRODUCTION 1 INSTALLING THE SIM CARD 1.5 To correctly insert the SIM Card, proceed as follows:
1. Turn off the Datalogic Memor. 2. Press the latch release button and pull the latch down, as indicated in the figure below:
3. Remove the cover and the battery pack, then open the SIM card slot by pulling up the locking plate:
7 1 1 DATALOGIC MEMOR 4. Shift the cardholder to the left and then pull it up; insert the SIM Card with its contacts downward and its round corner at the bottom:
5. Lock the card into place by pushing the cardholder down and then shifting it to the right. Pull the locking plate down. 6. 7. Close the battery cover properly, by pressing the latch release button and pulling the latch down. Follow proper ESD precautions to avoid damaging the SIM card. Proper ESD precautions include, but are not limited to, working on an ESD mat and ensuring that the operator is properly grounded. Do not force the card. If you feel resistance, remove the card, check the orientation, and reinsert it. Do not use the SIM card slot for any other accessories. CAUTION The SIM Card option is not available in 802.11b/g radio and batch models. NOTE 8 INTRODUCTION 1 1.5.1 Removing the SIM Card To remove the SIM card, follow the steps above to access the SIM area, and remove it from its slot. All the basic functionalities normally associated to the SIM card are managed by the terminal (GPRS connectivity, phone calls, SMS handling). It is possible that not all the services connected to the SIM card can be used or can be managed by the terminal. NOTE 9 1 1 1.6 ACCESSORIES
Cradles DATALOGIC MEMOR 94A151111 Datalogic Memor Single Cradle 94A151121 Datalogic Memor Powered Vehicle Dock
Batteries 94ACC1368 DL-MEMOR Standard Battery CVR2 (Li-Pol or Li-Ion battery pack 1000 mAh@3.7 V) 94ACC1367 DL-MEMOR Large Capacity Battery CVR2 (Li-Pol or Li-Ion battery pack 2000 mAh@3.7 V)
Power Supply 94ACC1324 PG5-30P35 AC/DC Power Supply EU/USA Plug 94ACC1334 PG5-30P35 AUS. Plug Adapter (10pcs) 94ACC1335 PG5-30P35 UK Plug Adapter (10pcs) 94ACC1339 PG5-30P35 EU Plug Adapter (10pcs)
Cables 94A051016 CAB-421 Mini USB Straight Cable 94A051022 WIN-NET Serial Cable (HRS ST40X-18S-CV) 94A051024 CAB USB Type Standard A (4 pin F) to Mini A (5 pin M) 94A051966 CAB Direct Cigarette Lighter Adapter
Various 94ACC1328 Datalogic Memor Stylus Pens (10 pcs) 94ACC1365 Datalogic Memor Headset 94ACC1366 Datalogic Memor Softcase NOTE Use only a Datalogic Mobile-approved power supply and cables. Use of an alternative power supply will invalidate any approval given to this device and may be dangerous. 1.7 OPERATING SYSTEM Datalogic Memor supports two different operating systems: Windows CE and Windows Mobile. For further information regarding Windows Mobile refer to the website:
http://www.microsoft.com/windowsmobile. 10 CONNECTIONS 2 2 CONNECTIONS 2.1 USB CONNECTION You can use any standard mini USB cable to directly connect the Datalogic Memor to a host computer to transfer data through the USB interface. A Key:
B C A) Host Computer B) Standard Mini USB cable C) Datalogic Memor Connection through the cradle is compliant to 2.0 USB standard. NOTE The Single Cradle can be connected to the Host by any standard mini USB cable to transfer data through the USB interface. A C B D*
Key:
A) Host Computer B) Standard Mini USB cable C) Single Cradle D)
*Power Supply (only necessary for battery charging) In this case the power supply is only necessary for battery charging. Insert the power supply plug into the power jack on the base of the cradle and attach the power supply to a power outlet. 11 DATALOGIC MEMOR Connection through the cradle is compliant to 1.1 USB standard. The actual data transfer speed can be appreciably lower than the maximum theoretical speed. 1 2 NOTE NOTE 12 CONNECTIONS 2 2.2 CONNECTION TO USB PERIPHERALS You can use a standard A (4 pin female) to mini A (5 pin male) USB cable to connect the Datalogic Memor to a keyboard or a memory. For all these devices maximum current withdrawal must be below 100mA. B A Key:
C A Keyboard with USB interface C 94A051024 (Standard A to Mini A USB cable) B Datalogic Memor A Key:
C B A USB hard drive/ external memory source B Datalogic Memor C 94A051024 (Standard A to Mini A USB cable) Connect first the USB peripheral to the cable, and then the cable to the Datalogic Memor. Datalogic Memor works with most of mentioned USB peripherals. In any case, we cant guarantee good operations with all devices available on market place. Connection through the cradle is compliant to 1.1 USB standard. NOTE NOTE NOTE 13 DATALOGIC MEMOR The actual data transfer speed can be appreciably lower than the maximum theoretical speed. 1 2 NOTE 14 CONNECTIONS 2 2.3 RS232 CONNECTION You can use a cable to directly connect the Datalogic Memor to a host computer to transfer data through the RS232 interface. A Key:
B C C) Datalogic Memor A) Host Computer B) 94A051022 WIN-NET
(HRS ST40X-18S-CV) The Single Cradle can be connected to the Host by any standard 9-pin serial null-modem cable for RS232 communications. Once the Host has been turned on, insert the Datalogic Memor mobile computer into the cradle. A Key:
B C D A) Host Computer B) 94A051020 CAB-427 Null-Modem C) Single Cradle D)
*Power Supply (only necessary for battery charging) In this case the power supply is only necessary for battery charging. Insert the power supply plug into the power jack on the base of the cradle and attach the power supply to a power outlet. If the mobile computer supports Windows Mobile, before plugging the RS232 cable you have to check the 'COM1 Enable' option on the 'System, Configuration' window. (Start -> Programs -> System Configuration). CAUTION 15 1 2 DATALOGIC MEMOR WLAN CONNECTION 2.4 Datalogic Memor 802.11b/g radio models can communicate with the host using the on-board radio frequency component and an Access Point connected to the host computer. For models using the 802.11g radio, you can find information about the applet for radio configuration: http://www.summitdatacom.com/SCU.htm. To launch this utility you can tap the specific icon if it's visible on the taskbar or:
1. On Windows CE devices, you can open Connections folder or Control Panel from desktop and select the 'Summit Client Utility' icon. 2. On Windows Mobile devices, you can select the menu item: Start-
>Programs->Summit and tap the Summit Client Utility icon. A B C Key:
A) Datalogic Memor B) Access Point C) Host Application Server 16 CONNECTIONS 2 NOTE NOTE NOTE NOTE 802.11g radio module is on by default, in order to avoid wasting energy, you can switch it off using the Wireless Communications applet. the radio connection. When Suspending the terminal powers off the 802.11b/g radio and drops terminal resumes, depending on the radio power mode and security protocol selected, it may take up to 30 seconds for the 802.11b/g radio driver to re-associate the radio to the network. the Area coverage and radio performance may vary, due to environmental conditions, access points types or interference caused by other devices (microwave ovens, radio transmitters, etc.) In case of heavy usage the Datalogic Memor could get warm, this is normal and does not mean a malfunction. 17 1 2 DATALOGIC MEMOR 2.5 WPAN CONNECTION Datalogic Memor mobile computer models with Bluetooth can communicate with other Bluetooth enabled devices, such as a printer, within a range of 10 m, using the onboard Bluetooth module. B A Key:
A) Datalogic Memor B) Bluetooth printer In order to avoid wasting energy, the Bluetooth module is off by default. If you need to have Bluetooth working, the module must be powered on using the Wireless Communications applet (see par. 3.7.4), and perform the Discovery procedure (see par. 3.8.2). Suspending the terminal powers off the Bluetooth radio and drops the piconet (Bluetooth connection). When the terminal resumes, the Bluetooth radio driver to re-initialize the radio. takes approximately 10 seconds for it Area coverage and Bluetooth radio performance may vary, due to environmental conditions or interference caused by other devices (microwave ovens, radio transmitters, etc.), etc. NOTE NOTE NOTE 18 CONNECTIONS 2 2.6 WWAN CONNECTION Datalogic Memor GSM models enhance your connectivity solutions giving you an opening to an international wireless infrastructure that is the global standard. GSM (Global System for Mobile communications) is a digital mobile phone system based on TDMA; it utilizes the 850, 900, 1800 and 1900 MHz bands. In order to use a WWAN Connection you have to install a SIM Card (see instructions on par. 1.5). NOTE NOTE NOTE NOTE In order to avoid wasting energy, the GSM module is off by default. If you need to have GSM working, the module must be powered on using the Wireless Communications applet
(see par. 3.7.4). Suspending the terminal powers off the GSM radio and drops the connection. When the terminal resumes, if the connection was managed by Microsoft is automatically restored, otherwise, the radio connection must be manually re-initialized. Internet Explorer, it The GSM voice capability of this mobile computer has to be addressed to occasional use, in well covered areas. If the coverage is poor, the voice quality can be highly affected. Calls can be made or received using the Datalogic Memor as a phone handset, by the Datalogic Memor headset or by a Bluetooth headset. the SIM Card option is not available in 802.11g radio and batch models 19 DATALOGIC MEMOR During a call, you can set the speaker volume by moving the joystick up and down. In case of heavy usage the Datalogic Memor could get warm, this is normal and does not mean a malfunction. 1 2 NOTE NOTE 20 CONNECTIONS 2.7 CONNECTION CABLES
RS232 Direct Connection:
2 94A051022 WIN-NET SERIAL CAB (HRS ST40x-18S-CV) Datalogic Memor 9 side 10 11 12 13 15 14 8 7 RXD TXD CTS RTS DSR DCD DTR RI GND
Power Supply Polarity:
VEXT GND TXD RXD RTS CTS DTR DCD DSR RI GND 3 2 7 8 4 1 6 9 5 HOST/PC side 9-pin (female) 21 1 2 DATALOGIC MEMOR 2.8 WIRELESS AND RADIO FREQUENCIES WARNINGS Use only the supplied or an approved replacement antenna. Unauthorized antennas, modifications or attachments could damage the product and may violate laws and regulations. Most modern electronic equipment is shielded from RF signals. However, certain electronic equipment may not be shielded against the RF signals generated by Datalogic Memor. to follow Datalogic recommends persons with pacemakers or other medical devices the same recommendations provided by Health Industry Manufacturers Associations for mobile phones. Persons with pacemakers:
Should ALWAYS keep this device more than twenty five
(25) cm from their pacemaker and/or any other medical device;
Should not carry this device in a breast pocket;
Should keep the device at the opposite side of the pacemaker and/or any other medical device;
Should turn this device OFF or move it immediately AWAY that interference is taking place. Should ALWAYS read pacemaker or any other medical device guides or should consult the manufacturer of the medical device to determine if it is adequately shielded from external RF energy. is any reason to suspect there if In case of doubt concerning the use of wireless devices with an implanted medical device, contact your doctor. Turn this device OFF in health care facilities when any regulations posted in these areas instruct you to do so. Hospitals or health care facilities may use equipment that could be sensitive to external RF energy. improperly installed or RF signals may affect in motor inadequately shielded electronic systems vehicles. Check with its representative regarding your vehicle. You should also consult the manufacturer of any equipment that has been added to your vehicle. the manufacturer or WARNING WARNING WARNING WARNING WARNING 22 CONNECTIONS 2 WARNING WARNING An air bag inflates with great force. DO NOT place objects, including either installed or portable wireless equipment, in the area over the air bag or in the air bag deployment area. If vehicles wireless equipment is improperly installed and the air bag inflates, serious injury could result. Turn off the device when in any area with a potentially explosive atmosphere. Observe restrictions and follow closely any laws, regulations, warnings and best practices on the use of radio equipment near fuel storage areas or distribution fuel areas, chemical plants or where some operation involves use of explosive materials. Do not store or carry flammable liquids, explosive gases or materials with the device or its parts or accessories. Areas with a potentially explosive atmosphere are often, but not always, clearly marked or showed. Sparks in such areas could cause an explosion or fire, resulting in injury or even death. 23 1 3 DATALOGIC MEMOR 3 USE AND FUNCTIONING The use of the Datalogic Memor depends on the application software loaded. However there are several parameters that can be set and utilities that can be used to perform some basic functions such as data capture, communications, file management, etc. 3.1 STARTUP The Datalogic Memor turns on when the battery pack or the external supply is inserted. After the battery pack is installed, use the [ON/OFF] key to turn the mobile computer on and off. As soon as the mobile computer is on, the Windows CE 5.0/ Windows Mobile desktop configuration will appear on the screen. Wait a few seconds before starting any activity so that the mobile computer completes its startup procedure. Windows CE Desktop Windows MobileToday Screen Use the stylus (par. 3.1.1) or joystick (par. 3.1.2) as suggested to select icons and options. The mobile computer goes into power-off (low power with display and keyboard backlight off), when it is no longer used for more than a programmable timeout, which is defined in the POWER applet of the Control Panel. In this mode it can be awakened (resuming operation) by the [ON/OFF] key. 24 USE AND FUNCTIONING 3 The mobile computer can also be awakened or turned off by the application program. NOTE 25 1 3 DATALOGIC MEMOR 3.1.1 Using the Stylus The stylus selects items and enters information. The stylus functions like a mouse. Tap:
Touch the screen once with the stylus to open items and select options (Windows Mobile only). Double Tap:
Touch the screen twice with the stylus to open items and select options (Windows CE only). Drag:
Tap-and-
hold:
Hold the stylus on the screen and drag across the screen to select text and images. Drag in a list to select multiple items. Tap and hold the stylus on an item to see a list of actions available for that item. On the pop-up menu that appears, tap the action you want to perform. To recalibrate the touch screen use the Stylus Applet (see par. 3.7.5) of use harsh screen applications, Use only original Datalogic styluses supplied with the product itself. In protectors should be taken into consideration, in order to extend the touch screen operating life. To prevent damage to the screen, do not use sharp devices or any device other than the Datalogic Mobile-provided stylus. Do not apply not necessary high pressures on the screen. For applications where an intensive use of the touch screen is foreseen, please consider that touch screen components are subject to progressive wear. CAUTION 26 USE AND FUNCTIONING 3 3.1.2 Using the Joystick The joystick selects items and enters information. The joystick can work like the directional arrow keys of a PC keyboard or can function like a mouse and control the mouse pointer. It is possible to switch between the two functioning modes by pressing blue modifier + BKSP keys in sequence. Arrow Keys Mode
(default):
Mouse Mode:
Move in the four directions: move forwards, backwards, upwards or downwards within text fields, scroll through a Menu list or browse among folder files. Press down: selects the current function (like the Enter key). Move in the four directions: move the mouse pointer forwards, backwards, upwards or downwards. Press down: like the left click of the mouse. NOTE During a phone call, you can set the speaker volume by moving the joystick up and down. 27 1 3 DATALOGIC MEMOR 3.2 WINDOWS MOBILE WELCOME WIZARD In Windows Mobile, at the very first Memor startup, following a clean boot or following a registry restore to default values, the mobile computer startup (see par. 3.1 is preceded by the Welcome Wizard. Welcome Wizard Screen The Welcome Wizard allows the user to calibrate the touch screen (see par. 3.7.5) and to configure an email account and a password to protect the terminal. Touch Screen Calibration Screen 28 USE AND FUNCTIONING 3 3.3 DATA CAPTURE To capture data first of all select the barcode icon on the bottom-right side of the display and tap the 'Capture' menu item then proceed with the following directions. To configure and enable data capture parameters refer to par. 3.6. 3.3.1 Laser Data Capture To scan barcodes, point the Datalogic Memor laser model onto the code from a distance within the reading range while pressing the SCAN key. The lighted band emitted by the laser must completely intercept the barcode as shown in the figure below. If the scan has taken place correctly:
the Good Read LED gets constant Green for a configurable time;
if enabled, the GoodReadSound emits an acoustic signal;
if enabled, the GreenSpot projects a green spot onto the bar code image. Remove the protective film cover over the Laser Output Window before use. NOTE 29 1 3 DATALOGIC MEMOR Imager Data Capture 3.3.2 The Datalogic Memor Imager captures a picture of the entire bar code. The omni-directional scanning does not require that the operator orient the bar code to align with the scan pattern. To read a 1D or 2D code, simply point the Datalogic Memor Imager model onto the code and press the SCAN Key. The Datalogic Memor Imager uses an intelligent aiming system pattern, similar to those on cameras, indicating the field of view, which should be positioned over the code:
Aiming System If the aiming system pattern is centered over the entire symbology as shown in the following figure, either wait for the timeout or release the Scan key to capture the image. A red beam illuminates the code, which is captured and decoded. You will get a good read. 30 USE AND FUNCTIONING Linear barcode 2D Matrix symbol BX3 3 Relative Size and Location of Aiming System Pattern The field of view changes its size as you move the reader closer or farther away from the code. The field of view indicated by the aiming system pattern will be smaller when the Datalogic Memor Imager is closer to the code and larger when it is farther from the code. Symbologies with smaller bars or elements (mil size) should be read closer to the unit. Symbologies with larger bars or elements (mil size) should be read farther from the unit. (See par. 5.1 for further details). If the scan has taken place correctly:
the Good Read LED gets constant Green for a configurable time;
if enabled, the GoodReadSound emits an acoustic signal. 31 1 3 DATALOGIC MEMOR 3.4 DESCRIPTION OF THE KEYS The Datalogic Memor provides a 23-key alphanumeric keyboard + ON/OFF key + joystick. The following image shows this keyboard. 32 USE AND FUNCTIONING Main Keys Function KEY FUNCTION 3 It starts barcode data capture. The joystick lets you move forwards, backwards, upwards or downwards, scroll through a Menu list, browse among folder files or select functions if pressed down. It can work in two functioning modes: Arrow Keys Mode and Mouse Mode. Its possible to switch between them by pressing blue modifier + BKSP keys in sequence (see par. 3.1.2) Yellow modifier: when pressed before a standard key, it enables the character or function printed in yellow above the key. Blue modifier: when pressed before a standard key, it enables the character or function printed in blue above the key. It powers the Datalogic Memor ON or OFF. It is placed on the upper left side of the terminal. The ALPHA key is used to alternate numeric and alphanumeric use of the 10 numeric keys. Special Function Icons ICON FUNCTION After a yellow modifier key press, it opens the Start menu. After a yellow modifier key press, it opens the file manager. After a yellow modifier key press, it switches ON/OFF the display backlight. After a blue modifier key press, it switches ON/OFF the keyboard backlight. After a blue modifier key press, it locks and unlocks the keyboard. 33 1 3 DATALOGIC MEMOR 3.4.1 Resetting the Memor Windows CE There are several reset methods for the Memor. A warm boot terminates an unresponsive application and clears the working RAM, but preserves both the file system and the registry. A cold boot forces all applications to close and clears working RAM and files not resident on the persistent flash memory. Registry is restored from persistent memory if available or returned to factory default. A Clean Boot restores the Memor to factory configuration: registry and file system return to factory default. WARM BOOT A warm boot closes all applications, clears the working RAM, but preserves the file system and registry. If an application "hangs" initiate a warm boot to terminate the application. To perform a warm boot, press these keys simultaneously:
COLD BOOT A cold boot is a complete reset of the Memor in which all applications are forcibly closed and RAM is completely cleared. Registry is restored from persistent memory if a saved copy is available (see 3.7.2) and RAM file system completely erased. You will lose any applications and data (registry too) which are not stored in persistent flash memory. A cold boot is necessary when the Windows CE operating system locks up and the warm boot command does not work. To perform a cold boot, press these keys simultaneously:
CLEAN BOOT A clean boot is a cold boot that causes the device to be restored to factory configuration. The Memor will reset to its factory configuration, clear the working RAM and initialize the file system. You will lose any applications and data stored in persistent flash memory. At the next startup the system will ask to recalibrate the touch screen. To perform a clean boot, follow these steps:
1. Perform a Cold Boot (see Cold Boot). 2. Quickly release all the keys when the screen goes black. 3. Within 1 second press and hold down the Esc and 0 keys until the left orange led starts blinking. 4. Release the Esc and 0 keys. 34 Clean Boot Factory default Clean disk Factory default USE AND FUNCTIONING 3 5. Enter 1 to proceed with the Clean Boot sequence. Enter 0 to cancel the Clean Boot and proceed with a Cold Boot. Warm Boot Cold Boot REGISTRY Preserved Restored from flash (if available) Flash Disk
(Backup Folder) RAM File System Preserved Preserved Preserved Reinitialized (factory default) Before performing a reset, it is recommended to:
execute a system backup to keep your more important files and applications persistent. See par. 3.9;
save the registry to non-volatile memory to guarantee the persistence of the Windows configuration. See par. 3.7.2. CAUTION
Windows Mobile There are several reset methods for the Memor. A warm boot terminates an unresponsive application and clears the working RAM, but preserves the file system. Registry are restored from persistent memory if available or returned to factory default. A cold boot forces all applications to close reinitializing completely the system. It clears the working RAM, but the file system is preserved. Registry is restored from persistent memory if available or returned to factory default. A clean boot restores the Memor to a clean configuration: both the registry and the file system return to a clean status that conform to factory default, unless the user has installed an additional package. Warm Boot A warm boot closes all applications and clears the working RAM, but preserves the file system. Registry are restored from persistent memory if a saved copy is available (see Registry Applet, par. 3.7.2) or returned to factory default. If an application hangs, initiate a warm boot to terminate the application. To perform a warm boot, press and hold the following keys simultaneously:
Cold Boot A cold boot is a complete reset of the Memor in which all applications are forcibly closed and the RAM is completely cleared. Registry is restored from persistent memory if a saved copy is available (see Registry Applet, par. 3.7.2). Applications and data stored on file system are preserved. A cold boot is 35 1 3 DATALOGIC MEMOR necessary when the Windows Mobile operating system locks up and the warm boot command does not work. To perform a cold boot, press and hold the following keys simultaneously:
Clean Boot A clean boot is a cold boot that causes the device to be restored to a clean configuration. The Memor will be reset to its factory configuration only if the user has not installed any additional package. Please note that you will lose any applications and data stored in persistent flash memory. To perform a clean boot, follow these steps:
1. Perform a Cold Boot (see Cold Boot). 2. Quickly release all the keys when the screen goes black. 3. Within 1 second press and hold down the Esc and 0 keys until the left orange led starts blinking. 4. Release the Esc and 0 keys. 5. Enter 1 to proceed with the Clean Boot sequence. Enter 0 to cancel the Clean Boot and proceed with a Cold Boot. Warm Boot REGISTRY Restored flash Preserved File System from Cold Boot Restored flash Preserved from Clean Boot Clean configuration user config) Clean Installation (no user files)
(no 36 USE AND FUNCTIONING 3 3.5 STATUS INDICATORS 3.5.1 LED Status The Datalogic Memor provides three different LEDs signaling the mobile computer status. LED Good Read and General Purpose
(left side) STATUS Green Green/Red Charging Status
(right side) Green constant It is constant for a configurable time to signal that a successful read has occurred. It is also available to the application program. is constant once It process has been completed. the charging Red constant It is constant while charging. 37 1 3 DATALOGIC MEMOR 3.5.2 Taskbar The Taskbar provides information about the time, the battery level, the keyboard function, and the decoding status. ICONS Time and Battery Icons DESCRIPTION It displays the time. In Windows CE, they are representative of five different icons indicating the battery level. The icon is partially green when the power left is >20% and partially red colored when the power left is <20%. In Windows Mobile, it displays the system battery status. It indicates that the battery is charging (Windows CE). It indicates that the battery is charging (Windows Mobile). Keyboard Status Icons It indicates that the blue FUNC key has been pressed and is going to affect the next key press. It indicates that the yellow FUNC key has been pressed and is going to affect the next key press. It indicates that the ALPHA key has enabled the selection of the characters printed in orange. It indicates the NUMERIC key selection, the ALPHA key has not been pressed. It indicates that the ALPHA key has enabled the selection of the characters printed in orange and the Capslock is active. It indicates that the keyboard is locked. Decoding Status Icons It indicates that the decoder is active (green), not active
(grey). 38 USE AND FUNCTIONING Windows CE Taskbar Windows Mobile Taskbars 3 39 1 3 DATALOGIC MEMOR 3.6 DATA CAPTURE CONFIGURATION From the Windows CE Taskbar, tap the "Decoding" icon to open a dropdown menu. Decoding can also be accessed from the Control Panel. By selecting the Info item from this drop-down menu you can access information about the Scanner and the Software; the Configure item opens the configuration applet (Data Capture Configuration Window), while Capture accesses the data capture applet (Data Capture Window), which enables code reading. The last menu item (Wedge) enables Wedge Emulation. From the Windows Mobile Start menu, tap Settings -> System -> Decoding. The
"Decoding" icon opens the configuration applet (Data Capture Configuration Window). Windows CE Windows Mobile 3.6.1 Configure The Configuration applet contains the barcode scanning configuration parameters in a directory tree structure. The available barcode parameters are divided into two groups: Reader Parameters and Scan Parameters. The Reader Parameters depend on the type of scanner module installed on the mobile computer and allow barcode configuration (i.e. enable/disable Code 39, check digit control, etc.). The Scan Parameters are common to all scanner modules and allow control of the scanning device (i.e. beeper control, LED control, laser timeout, etc.). Each Data Capture screen window corresponds to a branch of the tree, and the name of the current branch is displayed at the bottom of each screen window. 40 USE AND FUNCTIONING 3 Data Capture Configuration Window The screen format shows two columns where the left column indicates branches or parameters. Branches have three dots in the right column (...). You can navigate through the tree structure using the stylus or keyboard arrows directly on the item field or from the menu. Parameters have their corresponding current values in the right column. You can edit parameter values using the stylus or keyboard arrows directly on the item field or from the menu. To change a value for example, select the line of the value to be changed, choose Edit from the Parameter Menu then choose a new value from the values listed in the box (see following figures). Selecting Data Capture Setup Parameters Alternatively using the stylus, you can tap once directly on the value on the right column; continue tapping until the desired value is reached. To activate a new configuration select the File ->Save Menu to send the new configuration to the barcode decoding software and save the new configuration. This will save the configuration to non-volatile memory preventing loss at the next system reset. 41 1 3 DATALOGIC MEMOR Reader Parameters The barcode reading parameters and values are dependent upon the type of scanner module mounted in your mobile computer. For a detailed list of parameters and of their configuration procedures, please refer to the SDK Help file on the CD. Scan Parameters The Scan Parameters are common to all scanner modules and allow control of the scanning device. The Scan parameters are described as follows:
ScanTimeout: the maximum time, in milliseconds, during which the scanner remains on without decoding any barcode. BeepType: if set to dual tone, the good read beep is a sequence of high and low pitch sounds. If set to monotone, the beep is a single pitch sound. BeepDuration: the time interval, in milliseconds, during which the beeper will sound when the scanner reads a code. To disable the beeper, set this value to 0. BeepFrequency: determines the frequency in Hertz of the beeper. GoodReadSound: is the beep sound emitted when the scanner reads a code. LedDuration: the length of the good-read led pulse, in milliseconds. LedPulses: the number of times the good-read led pulse is emitted when the scanner reads a code. ContinuousMode: disables the effect of the ScanTimeout parameter. KeyboardEmulation: if enabled all scanned data are transformed into keyboard events and can therefore be displayed and saved to a file as if input from the mobile computer keyboard. SoftTrigger: when enabled, the laser can be turned on/off by the application software. ScanAlwaysOn: enables the scanner for barcode reading independently from the application software. GreenSpotDuration: determines the duration (measured in milliseconds) of the green spot feedback, which provides a good read green dot directly on the code, where the operator usually tends to be looking. NotPrintableChar: if set to Remove, all not printable characters included in the scanned data are deleted and the final barcode will include only printable characters. ScanButton: enables/disables the scan button. If the scan button is disabled, the reader can be triggered under software control. 42 USE AND FUNCTIONING 3 Default Settings The following tables contain the default values for the major barcode setup parameters, according to the type of scan engine mounted on the mobile computer. For a complete list of parameters and of their configuration procedures, please refer to the SDK Help file on the CD. SCAN PARAMETERS ScanTimeout BeepType BeepDuration BeepFrequency GoodReadSound LedDuration LedPulses ContinuousMode KeyboardEmulation SoftTrigger ScanAlwaysOn GreenSpotDuration NotPrintableChar ScanButton BARCODE SYMBOLOGY SPECIFIC READER PARAMETERS UPC A UPC E EAN 8 EAN 13 UPC/EAN/JAN Code 39 Code 39 Full ASCII Code 32 2/5: Interleaved 2/5: Industrial 2/5: Matrix Code 128 EAN 128 Codabar LASER MODELS IMAGER MODELS 5000 Not available Not available Dual tone Not available 20 Not available 2000 Beep.wav Beep 200 ms 200 ms 1 1 Disabled Disabled Enabled Enabled Enabled Enabled Disabled Disabled Not available 1000 Leave Leave Enabled Enabled LASER MODELS IMAGER MODELS Enabled Enabled Enabled Enabled Not available Enabled Disabled Disabled Enabled Disabled Disabled Enabled Enabled Disabled Enabled Enabled Disabled Not available Enabled Not available Not available Enabled Disabled Enabled In the Imager models these codes may only be enabled or disabled as a group by the UPC/EAN/JAN family selection (see a few lines below). 43 1 3 DATALOGIC MEMOR BARCODE SYMBOLOGY SPECIFIC READER PARAMETERS MSI Plessey Code 93 Code 11 GS1 Databar GS1 Databar Omnidirectional GS1 Databar General GS1 Databar Limited GS1 Databar Expanded PDF - 417 Data Matrix QR POSTNET PLANET Japan Post Australia Post KIX Code Royal Mail Code (RM4SCC) LASER MODELS IMAGER MODELS Not available Disabled Not available Disabled Enabled Disabled Disabled Not available Enabled Disabled Not available Disabled Enabled Not available Enabled Disabled Disabled Enabled Enabled Not available Enabled Not available Not available Enabled Not available Not available Not available Not available Not available Not available Disabled These codes may be enabled individually but are disabled as a group. 44 USE AND FUNCTIONING 3 3.6.2 Capture The Data Capture applet (Capture) enables code reading. Data Capture Window Data Capture can also be enabled through the Configuration applet by selecting File ->Scanner from the main menu, or by enabling the parameter Scan Always On in the Scan Parameters branch. Enabling the Data Capture 45 1 3 DATALOGIC MEMOR 3.7 CONTROL PANEL From the Windows CE Desktop, double tap on the "My Device" icon and then double tap on the "Control Panel" icon to open the Windows CE control panel main window. The Control Panel can also be launched from Start ->Settings -
>Control Panel. APPLET programs are displayed as icons; one icon corresponds to each APPLET. Windows CE Control Panel From the Windows Mobile Start menu, tap Settings. A three tab dialog opens:
Personal, System, Connections. APPLET programs are displayed as icons; one icon corresponds to each APPLET. Windows Mobile Control Panel 46 USE AND FUNCTIONING 3 3.7.1 Buttons To configure the way up/down and the rest of keys control repeats, use the Up/Down Control applet (Start -> Settings -> Personal -> Buttons -> Up/Down Control). Windows CE Buttons Icon Windows Mobile Buttons Icon You can also select to wake up the terminal by the SCAN key. To assign desired applications to be launched by one of the keys, refer to DFU Reference Guide. 47 1 3 DATALOGIC MEMOR 3.7.2 Registry The REGISTRY ADMIN applet provides management of Windows CE 5.0/
Windows Mobile registry. From the Windows CE control panel main window, , select the REGISTRY ADMIN applet by double tapping the Registry Admin icon. From the Windows Mobile Start menu, tap Settings -> System ->Registry Admin. Select the REGISTRY ADMIN applet by tapping the Registry Admin icon. The Registry Administration Main window appears. Two functions are available:
Save Registry allows permanently saving the Windows configuration
(example: custom configuration of screen desktop background color, or network adapter configuration) to non-volatile memory (SAVE button). Restore Default Registry allows restoring the initial factory default configuration (Restore Default button). After restoring the factory default configuration, you must perform a warm boot. Saving the registry to non-volatile memory guarantees the persistence of the Windows configuration in case of battery pack replacement, cold boot or warm boot on Windows Mobile.
Registry Administration Window 48 USE AND FUNCTIONING 3 3.7.3 Files Admin The FILES ADMIN applet enables control of the permanence of files in the Windows CE System Folder. Because Windows Mobile mounts the entire file system in persistent store
(rather than using RAM), it provides both users and applications with a reliable storage platform even in the absence of battery power. The FILES ADMIN applet is therefore not necessary. Two functions are available on the Files Admin Main window by means of two buttons:
Files Admin Main Window Save Session: with this button all files will be permanently saved in the
\Windows directory in non-volatile memory. This function guarantees the steady maintenance of every file produced during the current working session - even of sub-directories and relevant files - with the exception of the files belonging to the FLASH image. These current working session files will be backed-up in the \Backup\Windows directory. At the next cold boot, the files previously saved in the \Backup\Windows directory will be restored to the Windows directory (see par. 3.9). Safe Setup: with this button, the installation of software programs will be saved to non-volatile memory (Backup directory). Before doing this, it will be checked that the Backup directory has enough space to save the files. If the directory space is not enough, an error message will be shown and the program will exit the Safe Setup function. Two activating procedures are available for Safe Setup:
49 1 3 DATALOGIC MEMOR Select an installation file (for example, a .CAB cabinet file) from the Safe Setup mask. Safe Setup First Mask Then select \Windows or a relevant sub-directory in the path box. Then, Safe Setup will recognize the new files and directories present in the
\Windows directory, and will copy them to the \Backup\Windows directory. At the next cold boot, these files will be restored (see par. 3.9). Simply skip the first mask either by closing it or by pressing the ESC key. When it closes, a new mask will pop up: it will enable any type of installation (even remote ones like ActiveSync installations). Make sure the installation directory is \Windows or one of its sub-directories. After installation, the
\Backup\Windows directory. tap OK: Safe Setup will save the new files in
Safe Setup Second Mask 50 USE AND FUNCTIONING 3 3.7.4 Wireless Communications The WIRELESS COMMUNICATIONS applet provides management of the 802.11b/g radio, the Bluetooth and GSM modules. Windows CE Wireless Communications Icon Windows Mobile Connectivity Icon the mobile computer supports Windows CE, select If the WIRELESS COMMUNICATIONS applet by double tapping the Wireless Communications icon. The following window will appear:
Wireless Communications Window If the mobile computer supports Windows Mobile, the Wireless Manager application manages access to wireless connections. The 'Wireless Manager' is a sort of 'Control Panel' for bluetooth and phone modules. From here it's possible to turn on or off bluetooth and phone radio stacks. Open the Wireless Manager by tapping Start -> Settings -> Connections ->
Wireless Manager, or by tapping the Connectivity icon located at the top of the screen. The following window will appear:
51 1 3 DATALOGIC MEMOR Windows Mobile Wireless Communications Window 52 USE AND FUNCTIONING 3 3.7.5 Stylus Calibration You might need to recalibrate the touch screen (i.e. when you attempt to select one item with the stylus, another item is erroneously selected). To recalibrate the touch screen on Windows CE, complete the following steps:
1. Select Start > Settings > Control Panel > Stylus to open the Stylus Properties dialog as shown in Figure 1. 2. Adjust Double-Tap sensitivity if needed or desired. 3. Select the Calibration tab to open the Calibration application. Figure 1 4. Tap Recalibrate to open the Calibration screen shown in Figure 2. 5. Carefully press and briefly hold stylus on the center of the target. Repeat as the target moves around the screen. Press the <ESC> key to cancel the stylus calibration. 6. Press the <ENTER> key or tap the screen to accept the new calibration settings. Press the <ESC> key to keep the old settings. 7. New calibration settings are persistently saved in registry. 53 1 3 DATALOGIC MEMOR Figure 2 To recalibrate the touch screen on Windows Mobile, complete the following steps:
1. Select Start > Settings > System > Screen to open the Screen Settings dialog as shown in Figure 3. Figure 3 2. Tap Align Screen to open the Calibration screen shown in Figure 4. 3. Carefully press and briefly hold stylus on the center of the target. Repeat as the target moves around the screen. Press the <ESC> key at any time to cancel the stylus calibration. 4. By completing the calibration procedure you implicitly accept the new calibration settings. 5. New calibration settings are persistently saved in registry. 54 USE AND FUNCTIONING 3 Figure 4 Startup stylus calibration on Windows CE When starting the terminal, a stylus calibration screen comes up if valid calibration settings are not available. This happens following circumstances:
1. At the first startup of the terminal. 2. After restoring registry default settings using the applet Registry Admin the in and performing a warm boot. 3. After a Clean Boot. 4. After a Firmware Update (see par. 3.10). Startup stylus calibration on Windows Mobile When starting the terminal, a Welcome Wizard (with Stylus Calibration) comes up if valid calibration settings are not available. This happens in the following circumstances:
1. At the first startup of the terminal. 2. After restoring registry default settings using the applet Registry Admin and performing a boot. 3. After a Clean Boot. 55 1 3 DATALOGIC MEMOR 3.7.6 Volume Settings Windows CE From the Windows CE control panel main window, select the Audio applet by double tapping the Audio icon:
The Audio applet allows to set the recording volumes of the main microphone and of the headset microphone. Also, it allows to set the headset volume when the user is listening to an audio file. 56 Audio Window USE AND FUNCTIONING 3 From the Windows CE control panel main window, select the Volume & Sounds applet by double tapping the Volume & Sounds icon:
The Volume & Sounds applet allows to manage the audio features of the rear speaker and appears as follows:
Volume & Sounds Window 57 1 3 DATALOGIC MEMOR Windows Mobile From the Windows Mobile Start Menu, select Settings > Connections tab and click the Audio icon:
Audio Window The Audio applet allows to set the recording volumes of the main microphone and of the headset microphone. Also, it allows to set the headset volume when the user is listening to an audio file. 58 USE AND FUNCTIONING 3 icon on the right top of To set the speaker volume during a call, click the the Windows Mobile Start Menu. To set the front speaker or the headset speaker volume, use the right bar or move the joystick up and down. To set the rear speaker volume, use the left bar. To set the Bluetooth headset volume, tap Settings > Connections > Bluetooth Manager > Connections and select the headset. The following window will appear:
59 1 3 DATALOGIC MEMOR WINDOWS CONNECTIONS 3.8 To connect the Datalogic Memor to another device (i.e. Host PC) from Windows, several programs are available. These programs require specific electrical connections in order to function properly. 3.8.1 Microsoft ActiveSync Microsoft ActiveSync gives you the possibility to connect your desktop computer to your Datalogic Memor and synchronize the information on them. Synchronization compares the data on the Datalogic Memor with that on the desktop computer and updates both computers with the most recent information. With ActiveSync, it is possible to:
- Back up and restore Datalogic Memor data.
- Copy files between Datalogic Memor and desktop computer.
- Synchronize files by selecting a synchronization mode. You can establish an ActiveSync connection to your Datalogic Memor through the following electrical interfaces:
USB either directly or through the Single Cradle Bluetooth (see par. 3.8.2)
It is possible to constantly synchronize while connected to a desktop computer or, alternatively, synchronization can be performed only when the synchronize command is chosen. You can select which information types are synchronized and control how much data is synchronized. By default, ActiveSync does not automatically synchronize all types of information. Use ActiveSync options to turn synchronization on and off for specific information types. NOTE For example:
Synchronize Microsoft Word and Microsoft Excel files between the Datalogic Memor and the desktop computer. The files will automatically be converted to the correct format. In Windows Mobile before using the ActiveSync follow the directions described in par. 2.3 NOTE 60 USE AND FUNCTIONING 3 Visit the following Microsoft Web site for the latest in updates and technical information:
http://www.microsoft.com/windowsmobile/activesync/default.mspx NOTE ActiveSync Remote Microsoft ActiveSync Remote is no longer supported in Windows CE. For backward compatibility you can download it from the Internet. We suggest enabling the FTP Server and connecting to an FTP Client. See par. 3.8.4. NOTE 61 1 3 DATALOGIC MEMOR 3.8.2 Bluetooth Manager Device Setup Windows CE Bluetooth Manager Device Setup Before turning on Bluetooth, ensure that the two devices are within close range and that both Bluetooth-enabled devices are discoverable. 1. Open the Bluetooth control panel by tapping Start > Settings >
Connections tab > Bluetooth Manager. 2. Tap Settings. The Settings tab allows you to enable or disable the Bluetooth radio and specify settings for Incoming Connections. 3. Select or clear the Enable Bluetooth Radio check box:
Tap Find Me if you want to make the MemorTM visible to other Bluetooth devices for 60 seconds, allowing them to set up a connection. By default, Bluetooth is turned off. If you turn it on, and then turn off your device, Bluetooth also turns off. When you turn on your device again, Bluetooth turns on automatically. NOTE 62 USE AND FUNCTIONING 3 To create a Bluetooth partnership between your device and another device that has Bluetooth capabilities, ensure that the two devices are turned on, discoverable, and within close range. 1. Open the Bluetooth control panel by tapping Start > Settings >
Connections tab > Bluetooth Manager. 1. Search for the type of Device(s) you want to connect to by tapping Printer, Serial or All. The MemorTM will search for Bluetooth Devices within range. If you attempt to set up a connection when the Bluetooth Radio is disabled, you will receive a message reminding you that the radio is turned off, and asking you if you want to turn it on. Tap Yes if you need to enable the Bluetooth Radio. NOTE 3. Once searching is complete, Bluetooth Device Profiles will be displayed in the Discovery tab. You can set up a connection to a device on the list, or clear it from the list by tapping the Clear button:
63 1 3 DATALOGIC MEMOR To set up a connection:
1. From the list of available devices, double tap the one you want to activate, or select and then tap Connect. The resulting dialog will display services that are available on the device:
2. Select the service you want to connect to. The following table shows the icons that display for different types of service. Icon Service Dialup Networking Printer File Transfer Protocol (FTP) Object Exchange (OBEX) Object Push (OPP) Object Exchange (OBEX) ActiveSync Human Interface Device (HID) - Keyboard Serial Virtual Port allows you to specify the incoming port, which is used to communicate serially with an incoming device just as if it were a physical COM port. This option is available only if you have selected a Printer or Serial service. You can also select Encrypt or Authenticate from the Bluetooth control panel to apply or modify those settings. 1. To require Authentication, tap the checkbox, then tap OK. 2. The Authentication Request dialog will then open, requesting that you enter a PIN. Use the Input Panel to type in the PIN. 64 USE AND FUNCTIONING 3 3. Tap OK to complete. The dialog will also appear when an Authentication request is received from another device. Once you have set up a Pairing, you can view the settings by double-tapping its name from the Connections tab. The Pairing info dialog will display different options, depending on what type of device you have selected and what service you use. For a printer connection, tap the arrow to change the Virtual Port, or Delete to remove the device pairing. Tap Sync to initiate a Sync (available only if the service is an ActiveSync connection). 65 1 3 DATALOGIC MEMOR The icons displayed in the taskbar at the bottom of your MemorTMs screen will show you the state of the Bluetooth connection, as shown in the table below. Icon Name Disabled Icon Unpaired Icon Description Indicates that Bluetooth has been disabled. Indicates that the Bluetooth radio is on but the device is currently not paired to another. Indicates that the Bluetooth radio is on and the device is paired with at least another device. Indicates that the device is discoverable by other Bluetooth devices. Paired Icon Discoverable 66 USE AND FUNCTIONING 3 Windows Mobile Bluetooth Manager Device Setup The Bluetooth Device Properties icon will only be visible if Bluetooth hardware has been installed on the unit. NOTE Before turning on Bluetooth, ensure that the two devices are within close range and that both Bluetooth-enabled devices are discoverable. 4. Tapping Start > Settings > Connections tab > Bluetooth Manager to open the Bluetooth control panel. 5. Tap Settings. The Settings tab allows you to enable or disable the Bluetooth radio and specify settings for Incoming Connections. 6. Select or clear the Enable Bluetooth Radio check box:
Tap Find Me if you want to make the MemorTM visible to other Bluetooth devices for 60 seconds, allowing them to set up a connection. 67 1 3 NOTE DATALOGIC MEMOR By default, Bluetooth is turned off. If you turn it on, and then turn off your device, Bluetooth also turns off. When you turn on your device again, Bluetooth turns on automatically. To create a Bluetooth partnership between your device and another device that has Bluetooth capabilities, ensure that the two devices are turned on, discoverable, and within close range. 2. Open the Bluetooth control panel by tapping Start > Settings >
Connections tab > Bluetooth Manager. 1. Search for available Bluetooth Devices by tapping the button for the type of device you want (Printer, Serial or All) or tap Discovery to skip this step. The MemorTM will search for Bluetooth Devices within range. If you attempt to set up a connection when the Bluetooth Radio is disabled, you will receive a message reminding you that the radio is turned off, and asking you if you want to turn it on. Tap Yes if you need to enable the Bluetooth Radio. NOTE 2. Once searching is complete, Bluetooth Device Profiles will be displayed in the Discovery tab. You can set up a connection to a device on the list, or clear it from the list by tapping the Clear button:
68 USE AND FUNCTIONING 3 To set up a connection:
1. Double tap the device you want to activate, or select and then tap Connect. The resulting dialog will display services that are available on the device:
69 1 3 DATALOGIC MEMOR 2. Select the service you want to connect to. The following table shows the icons that display for different types of service. Icon Service Dialup Networking Printer File Transfer Protocol (FTP) Object Exchange (OBEX) Object Push (OPP) Object Exchange (OBEX) ActiveSync Human Interface Device (HID) - Keyboard Serial Virtual Port allows you to specify the incoming port, which is used to communicate serially with an incoming device just as if it were a physical COM port. This option is available only if you have selected a Printer or Serial service. You can also select Encrypt or Authenticate from the Bluetooth control panel to apply or modify those settings. 1. To require Authentication, tap the checkbox, then tap OK. 2. The Authentication Request dialog will then open, requesting that you enter a PIN. Use the Input Panel to type in the PIN. 70 USE AND FUNCTIONING 3 3. Tap OK to complete. The dialog will also appear when an Authentication request is received from another device. Once you have set up a Pairing, you can view the settings by double-tapping its name from the Connections tab. Tap the arrow to change the Virtual Port, or Delete to remove the device pairing. Tap Sync to initiate a Sync (available only if the service is an ActiveSync connection). 3.8.3 Windows Mobile Phone For information on Windows Mobile Phone use and functioning, refer to the Windows Mobile web site: http://www.microsoft.com/windowsmobile. 71 1 3 DATALOGIC MEMOR 3.8.4 FTP Server Setup The Datalogic Memor Windows CE Operating System includes a sample File Transfer Protocol (FTP) server. FTP is used for copying files to and from remote computer systems over a network using TCP/IP. You can establish a connection to your Datalogic Memor using its FTP Server through the following interfaces:
WLAN using the 802.11b/g radio Proceed as follows:
1. Create a registry file (extension .reg) to setup and enable FTP Server communication. A simple example file for anonymous logon is given below:
REGEDIT4
[HKEY_LOCAL_MACHINE\Comm\FTPD]
"DefaultDir"="\\"
"AllowAnonymousUpload"=dword:00000001
"UseAuthentication"=dword:00000000
"BaseDir"="\\"
"IsEnabled"=dword:00000001
"LogSize"=dword:00001000
"DebugOutputMask"=dword:00000017
"DebugOutputChannels"=dword:00000002
"IdleTimeout"=dword:0000012c
"AllowAnonymous"=dword:00000001
"AllowAnonymousVroots"=dword:00000001 2. Copy this file to the Datalogic Memor using ActiveSync. 3. Launch the .reg file from the Datalogic Memor. 4. Perform a warm boot on the Datalogic Memor. 5. From the PC > Explorer address bar (or running an FTP Client from the PC), enter the Datalogic Memor IP address. 72 For more information on FTP Client/Server connections refer to the following web page:
http://msdn2.microsoft.com/en-us/library/aa922316.aspx. NOTE USE AND FUNCTIONING 3 3.9 BACKUP DIRECTORY FILE MANAGEMENT All of the Windows CE 5.0 system files reside in RAM (volatile memory) except for the Backup directory, which resides in FLASH (non-volatile memory). Therefore the contents of the Backup directory are persistent even if the mobile computer is re-booted or the battery pack is changed. You can save your more important files that you don't want to lose due to mobile computer re-boot, in the Backup directory or create a sub-directory within Backup. Even though the Windows Directory resides in RAM, it often contains files or sub-directories created by the user or by installation programs that you don't want to lose at re-boot. To keep these files persistent it is necessary to copy them to the directory \Backup\Windows. This directory doesn't exist originally
(only Backup exists), and therefore it must be created. At the next cold boot, before activating the shell, Windows CE 5.0 will copy the contents including all sub-directories of \Backup\Windows to \Windows. Likewise, to maintain files that must be run at Windows CE 5.0 startup, (i.e. exe, .lnk, .vb, .htm, etc.), it is necessary to copy them to the directory
\Backup\Startup. This directory does not exist originally (only Backup exists), and therefore it must be created. The application programs will be run after any type of re-boot (both software and cold boot). As an alternative to the Safe Setup function, it is possible to copy the .cab files to the directory \Backup\Cabfiles (the Cabfiles sub-directory doesn't exists originally and must therefore be created) and perform a mobile computer cold boot to have the application installed. Once these files are copied to the directory \Backup\Cabfiles, the application will be run after each re-boot. From the second cold boot on, a message may be displayed such as
"<application name> is already installed. Re-install?". This message blocks the boot process. Press the [Enter] key to continue the system initialization. Even if the entire Windows Mobile file system reside in FLASH (non-volatile memory), the mechanism described above is supported also on Windows Mobile for backward compatibility. 3.10 FIRMWARE UPDATE The Datalogic Memor is equipped with a tool that implements a firmware update service. For further information, refer to DFU Reference Guide. 73 1 4 4 MAINTENANCE DATALOGIC MEMOR Rechargeable backup batteries and battery packs are not initially charged. Therefore the initial operation to perform is to charge them. See below. Annual replacement of rechargeable battery pack avoids possible risks or abnormalities and ensures maximum performance. NOTE CAUTION 4.1 CHARGING THE BATTERY PACK The battery pack autonomy varies according to many factors, such as the frequency of barcode scanning, RF usage, battery life, storage, environmental conditions, etc. NOTE The battery icon on the Taskbar indicates when the battery pack is low. It is possible to recharge the battery pack by connecting the power supply directly to the Datalogic Memor. Alternatively, it is also possible to recharge the battery pack by using a Single Cradle. Moreover recharging is possible by USB Direct connection with the host computer, but with longer charging times and in this case it is advised to keep the mobile computer off. During the charging process the LED positioned at the right side of the display is red constant. Once the charging process has been completed this LED is green constant (see par. 3.5). If the battery pack is removed from the mobile computer, it can be recharged by inserting it into the rear slot of a Single Cradle. Do not use the Datalogic Memor until batteries are charged for minimum 4 hours. CAUTION 74 MAINTENANCE 4 NOTE NOTE NOTE NOTE Even if the storage temperature range is wider, In order to achieve the longest battery life, store the terminal and the spare batteries between 20 to 30 C (68 to 86 F). The Batteries must be charged at a temperature ranging from 0 to +40 C (+32 to +104 F). recommended For temperature is + 35 C. At higher values the charging may slow down. the GSM models the maximum The battery level may not be displayed correctly for some minutes after the disconnection if the Datalogic Memor is disconnected from power supply before the charging cycle is completed. The Datalogic Memor could get warm during charging, this is normal and does not mean a malfunction. Use only a USB-IF compliant USB port as a charging source. 75 1 4 DATALOGIC MEMOR 4.2 REPLACING THE BATTERY PACK To correctly replace the battery pack, proceed as follows. 1. Turn off the Datalogic Memor. 2. Press the latch release button and pull the battery latch down as indicated in the figure below:
3. Remove the cover and the battery pack. 4. Install the new battery pack, first insert the bottom (contacts) side, then the upper side as indicated in the following figure:
5. Press the latch release button and pull the battery latch down to reinsert the cover. 76 MAINTENANCE 4 the battery cover As the mobile computer automatically shuts off, in order to retain data during the pack substitution. lifted, is CAUTION 77 1 4 WARNING DATALOGIC MEMOR Installing, charging and/or any other action should be done by authorized personnel and following this manual. The battery pack may get hot, explode, ignite, and/or cause serious injury if exposed to abusive conditions. If the battery pack is replaced with an improper type, there is risk of explosion. Do not place the battery pack in or near a fire or heat; do not place the battery pack in direct sunlight, or use or store the battery pack inside unventilated areas in hot weather; do not place the battery pack in microwave ovens, dryer, high pressure containers, on induction cookware or similar device. Doing so may cause the battery pack to generate heat, explode or ignite. Using the battery pack in this manner may also result in a loss of performance and a shortened life expectancy. Use only a Datalogic Mobile approved power supply. The use of an alternative power supply will void the product warranty, may cause product damage and may cause heat, explode or ignite. The area in which the units are charged should be clear of debris and combustible materials or chemicals. Do not use the battery pack of this terminal for power devices different from this mobile computer. Immediately discontinue use of the battery pack if, while using, charging or storing the battery pack, the battery pack emits an unusual smell, feels hot, changes colour or shape, or appears abnormal in any other way. Do not short-circuit the battery pack contacts connecting the positive terminal and negative terminal. This might happen, for example, when you carry a spare battery pack in your pocket or purse; accidental shortcircuiting can occur when a metallic object such as a coin, clip, or pen causes direct connection of the contacts of the battery pack (these look like metal strips on the battery pack). Shortcircuiting the terminals may damage the battery pack or the connecting object. Do not apply voltages to the battery pack contacts. Do not pierce the battery pack with nails, strike it with a hammer, step on it or otherwise subject it to strong impacts or shocks. 78 MAINTENANCE 4 Do not disassemble or modify (i.e. bend, crush or deform) the battery pack. The battery pack contains safety and protection devices, which, if damaged, may cause the battery pack to generate heat, explode or ignite. In case of leakage of liquid from the battery, avoid contact with liquid the skin or eyes. If the contact occurs, immediately wash the affected area with water and consult a doctor. Do not solder directly onto the battery pack. Do not expose the battery pack to liquids. Avoid any knocks or excessive vibrations. If the device or the battery is dropped, especially on a hard surface, you should take it to the nearest Authorised Repair Centre for inspection before continuing to use it. Do not replace the battery pack when the device is turned on. Do not remove or damage the battery packs label. Do not use the battery pack if it is damaged in any part. Battery pack usage by children should be supervised. Collect and recycle waste batteries separately from the device in comply with European Directive 2006/66/EC, 2002/95/EC, 2002/96/EC and subsequent modifications, US and China regulatory and others laws and regulations about environment. In order to guarantee an adequate operating autonomy, when replacing the battery pack the mobile computer checks the battery energy level. If the battery is not sufficiently charged, Datalogic Memor does not turn on
(when pressing the ON/OFF key). In this case, either substitute the battery pack with a charged one (sufficiently charged) or insert Datalogic Memor into a powered cradle or plug it into the direct power supply. To achieve the best battery life, turn off the radios not in use. WARNING NOTE NOTE 79 1 4 DATALOGIC MEMOR 4.3 CLEANING THE MOBILE COMPUTER Periodically clean the Datalogic Memor with a slightly dampened cloth. 80 TECHNICAL FEATURES 5 5 TECHNICAL FEATURES 5.1 TECHNICAL DATA Datalogic Memor Common Features Electrical Features Power DC Supply Battery Pack 5 V 5%
1 cell Li-Pol or Li-Ion 1100 mAh@3.7 V
(nominal) Alternatively 1 cell Li-Pol or Li-Ion 2000 mAh@3.7 V (nominal) Internal Backup Battery Rechargeable Ni-MH 30 mAh (2 x 15 mAh cells) Mobile Communication Features Windows CE COM Bluetooth Interface Serial Interface RS232 Windows COM Port COM5 COM1 COM6 Port COM5 COM1 COM6 USB 1.1 Wireless Features WLAN WPAN WWAN Environmental Features Working Temperature*
Storage Temperature Humidity**
Protection ESD Protection Drop Resistance***
IEEE 802.11b/g DSSS Bluetooth IEEE 802.15, Class 2, Version 2.0 GSM Quad-band (850, 900, 1800, 1900 MHz) Radio with accessible SIM card interface 0 to +50 C / 32 F to +122 F
-20 to +70 C / -4 to +158 F 10 to 80% non condensing for temperatures < 38 C IP 54 4 KV contact discharge, 8 KV air discharge 1.2 m / 3 ft 9 in
Battery must be charged at a C. For the GSM models the maximum recommended temperature is +35C. At higher values the charging may slow down Close to the limits of the working temperature, some display and/or battery performance degradation may occur. temperature from 0 to +40 ranging
** Multiple rapid humidity and/or temperature variations may cause condensing.
*** Multiple drops can permanently damage the device. 81 1 5 Hardware Features FLASH RAM Microprocessor Audio LEDs Display Keyboard Mechanical Features Dimensions (LxWxH) Weight
(depending on model) Programming Features Operating system Laser Models Decoded barcodes 1D Imager Models Decoded barcodes 1D Decoded barcodes 2D DATALOGIC MEMOR 256 MB 128 MB Marvell PXA 310 624 MHz Rear Speaker for beeps and ringing tones Microphone and Front Speaker for phone calls Headset Two-color Good Read/Programmable Charging Status 64K Color TFT LCD with 320 x 240 pixel resolution (QVGA), with LED backlight and touch screen, antiglare and antiscratch protection 23 Plastic Top - Backlit Keys + Joystick +
lateral ON/OFF key 802.11b/g / Batch models: 15.2 x 5.5 x 4.0 cm /
5.9 x 2.2 x 1.6 in EDGE models: 16.5 x 5.5 x 4.0 cm / 6.5 x 2.2 x 1.6 in 220 g / 7.76 oz (incl. 1100 mAH battery) 250 g / 8.81 oz (incl. 2000 mAH battery) Windows CE 5.0 Professional/ Windows Mobile 6.1 Professional UPC A, UPC E, EAN 8, EAN 13, Code 39, Code 39 Full ASCII, Code 32, Interleaved 2 of 5, Industrial 2 of 5, Matrix 2 of 5, Code 128, EAN 128, Codabar, MSI, Plessey, Code 93, Code 11, GS1 Databar UPC A, UPC E, EAN 8, EAN 13, UPC/EAN/JAN, Interleaved 2 of 5, Code 39, Code 39 Full ASCII, Codabar, Code 128, EAN 128, Code 93, GS1 Databar PDF417, DataMatrix, QR, MacroPDF, RSS Postal codes POSTNET, PLANET, Japan Post, Australia Post, KIX Code, Royal Mail Code (RM4SCC) 82 TECHNICAL FEATURES 5 Datalogic Memor Optical Features Datalogic Memor 1D Models 0.10 mm / 4 mils 50 65 104 12 scan/sec Maximum resolution Skew angle Pitch angle Scan rate - bidirectional Light source laser scanner VLD, wavelength 630~680 nm Safety class EN 60825-1:2001 Maximum resolution Scan rate Aiming Laser Safety class EN 60825-1:2001 Illumination System 0.13 mm / 5 mils 60 frames/sec VLD, wavelength 645~665 nm Laser: Class 2 Led (Illuminator): Class 1M LEDs 620~630 nm Laser: Class 2 Led (Green Spot): Class 1 Datalogic Memor 2D Models 83 1 5 DATALOGIC MEMOR 5.2 READING DIAGRAM Datalogic Memor 1D 400 300 200 100 0 100 200 300 400 mm 84 Typical Reading Diagram - Reading Zones (10 skew angle) 0,35 mm
(14 mils) 0,50 mm
(20 mils) 0,25 mm
(10 mils) 1,00 mm
(40 mils) 1,4 mm
(55 mils) 0,19 mm
(7,5 mils) 0,13 mm
(5 mils) 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 mm TEST CODES 6 6 TEST CODES 0.25 mm (10 mils) Code 39 2/5 Interleaved Code 128 EAN 13 EAN 8 High Density Codes
!17162H!
17162
"8Ndu 0123456784 test 80%
testw x(0B2DE5*KKKKLM(
80%
(6450*TRMN(
85 1 6 0.38 mm (15 mils) Code 39 Interleaved 2/5 Code 128 EAN 13 EAN 8 86 DATALOGIC MEMOR Medium Density Codes
!17162H!
17162 test 100%
0123456784
"8Ndu testw x(0B2DE5*KKKKLM(
(6450*TRMN(
100%
TEST CODES 0.50 mm (20 mils) Low Density Codes 6 17162 Code 128 0123456784 Interleaved 2/5 Code 39 !17162H!
"8Ndu testw x(0B2DE5*KKKKLM(
(6450*TRMN(
EAN 13 EAN 8 120%
120%
test 87 DATALOGIC MEMOR 2D Codes Example Example 1 6 Datamatrix ECC200 Inverse Datamatrix ECC200 88 GLOSSARY Access Point A device that provides transparent access between Ethernet wired networks and IEEE 802.11 interoperable radio-equipped mobile units. Hand-held mobile computers, PDAs or other devices equipped with radio cards, communicate with wired networks using Access Points (AP). The mobile unit (mobile computer) may roam among the APs in the same subnet while maintaining a continuous, seamless connection to the wired network. Barcode A pattern of variable-width bars and spaces which represents numeric or alphanumeric data in binary form. The general format of a barcode symbol consists of a leading margin, start character, data or message character, check character (if any), stop character, and trailing margin. Within this framework, each recognizable symbology uses its own unique format. Baud Rate A measure for data transmission speed. Bit Binary digit. One bit is the basic unit of binary information. Generally, eight consecutive bits compose one byte of data. The pattern of 0 and 1 values within the byte determines its meaning. Bluetooth A standard radio technology using a proprietary protocol. The onboard Bluetooth module in the mobile computer is compatible with the 1.1 protocol. Byte On an addressable boundary, eight adjacent binary digits (0 and 1) combined in a pattern to represent a specific character or numeric value. Bits are numbered from the right, 0 through 7, with bit 0 the low-order bit. One byte in memory can be used to store one ASCII character. Decode To recognize a bar code symbology (e.g., Codabar, Code 128, Code 3 of 9, UPC/EAN, etc.) and analyze the content of the bar code scanned. EEPROM Electrically Erasable Programmable Read-Only Memory. An on-board non-
volatile memory chip. Flash Disk Non-volatile memory for storing application and configuration files. 89 GSM Global System for Mobile communication. It is a standard for digital cellular communications, currently used in the 900 MHz and 1800 MHz bands. Host A computer that serves other mobile computers in a network, providing services such as network control, database access, special programs, supervisory programs, or programming languages. Liquid Crystal Display (LCD) A display that uses liquid crystal sealed between two glass plates. The crystals are excited by precise electrical charges, causing them to reflect light outside according to their bias. They use little electricity and react relatively quickly. They require external light to reflect their information to the user. Light Emitting Diode (LED) A low power electronic light source commonly used as an indicator light. It uses less power than an incandescent light bulb but more than a Liquid Crystal Display (LCD). RAM Random Access Memory. Data in RAM can be accessed in random order, and quickly written and read. RF Radio Frequency. RTC Real Time Clock. 90 INDEX A Accessories; 10 ActiveSync Remote; 61 B Backup Directory File Management; 73 Bluetooth Manager Device Setup; 62 Buttons; 47 C Charging the Batteries; 74 China RoHS Pollution Control Logos; xxi Cleaning the Mobile Computer; 80 Connection Cables; 21 RS232 Direct Connection; 21 Connections; 11 Connection to USB peripherals;
13 Control Panel; 46 Conventions; v D Data Capture; 29 Imager Data Capture; 30 Laser Data Capture; 29 Data Capture Configuration; 40 Datalogic Memor Description; 1 Default Settings; 43 Description of the Keys; 32 F FCC Compliance; xv Files Admin; 49 Firmware Update for Windows CE;
73 FTP Server Setup; 72 G General View; xxii Glossary; 89 I Industry Canada Compliance; xvii L Laser Safety; vii LED Class; xiii M Maintenance; 74 Micro SD Card Insertion; 5 Microsoft ActiveSync; 60 Models Description; 2 O Operating System; 10 P Package Contents; 4 Patents; xviii R Radio Compliance; xiii Reader Parameters; 42 Reading Diagram; 84 Reference Documentation; v References; v Registry; 48 Replacing the Batteries; 76 Resetting the Memor; 34 RS232 Connection; 15 S Safe Setup; 49 Safety Regulations; vi SAR Compliance; xviii Save Session; 49 Scan Parameters; 42 Services and Support; v SIM Card; 7 Special Function Icons; 33 Startup; 24 Status Indicators; 37 Stylus Calibration; 53 91 W WEEE Compliance; xix Windows Connections; 60 Windows Mobile Bluetooth Manager Device Setup; 67 Windows Mobile Phone; 71 Windows Mobile Welcome Wizard;
28 Wireless and Radio Frequencies Warnings; 22 Wireless Communications; 51 WLAN Connection; 16 WPAN Connections; 18 WWAN Connections; 19 T Taskbar; 38 Technical Features; 81 Test Codes; 85 U USB Connection; 11 Using the Joystick; 27 Using the Stylus; 26 V Volume Settings; 56 92 Datalogic Mobile S.r.l. Via S. Vitalino, 13 40012 - Lippo di Calderara Bologna - Italy 09 dichiara che declares that the dclare que le bescheinigt, da das Gert declare que el DL-MEMOR DL-MEMOR P/N: 944201019/ DL-MEMOR P/N: 944201022/
DL-MEMOR P/N: 944201014/ DL-MEMOR P/N: 944201015 sono conformi alle Direttive del Consiglio Europeo sottoelencate:
are in conformity with the requirements of the European Council Directives listed below sont conformes aux spcifications des Directives de lUnion Europenne ci-dessous:
der nachstehend angefhrten Direktiven des Europischen Rats:
cumple con los requisitos de las Directivas del Consejo Europeo, segn la lista siguiente:
2004/108/EC and 1999/5/EC R&TTE Questa dichiarazione basata sulla conformit dei prodotti alle norme seguenti:
This declaration is based upon compliance of the products to the following standards:
Cette dclaration repose sur la conformit des produits aux normes suivantes:
Diese Erklrung basiert darauf, da das Produkt den folgenden Normen entspricht:
Esta declaracin se basa en el cumplimiento de los productos con la siguientes normas:
ETSI EN 301 489-1 V1.8.1, APRIL 2008 :
FOR ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS
(ERM); ELECTROMAGNETIC COMPATIBILITY
(EMC) STANDARD FOR RADIO EQUIPMENT AND SERVICES;
PART 1: COMMON TECHNICAL REQUIREMENTS ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS
(ERM); ELECTROMAGNETIC COMPATIBILITY
(EMC) STANDARD FOR RADIO EQUIPMENT; PART 17:
2,4 GHZ WIDEBAND SPECIFIC CONDITIONS TRANSMISSION SYSTEMS, 5 GHZ HIGH PERFORMANCE RLAN EQUIPMENT AND 5,8 GHZ BROADBAND DATA TRANSMITTING SYSTEMS ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); WIDEBAND TRANSMISSION SYSTEMS;
DATA TRANSMISSION EQUIPMENT OPERATING IN THE 2,4GHZ ISM BAND AND USING WIDE BAND MODULATION TECHNIQUES;
HARMONIZED EN COVERING ESSENTIAL REQUIREMENTS UNDER ARTICLE 3.2 OF THE R&TTE DIRECTIVE INFORMATION TECHNOLOGY EQUIPMENT RADIO DISTURBANCE CHARACTERISTICS LIMITS AND METHODS OF MEASUREMENTS INFORMATION TECHNOLOGY EQUIPMENT IMMUNITY CHARACTERISTICS LIMITS AND METHODS OF MEASUREMENT INFORMATION TECHNOLOGY EQUIPMENT - SAFETY - PART 1 GENERAL REQUIREMENTS ETSI EN 301 489-17 V1.3.2, APRIL 2008 :
ETSI EN 300 328 V1.7.1, OCTOBER 2006 :
EN 55022:2006 (CLASS B) + A1:2007 :
EN 55024:1998 + A1:2001 + A2:2003 EN 60950-1:2001 + A11:2004 :
EN 62311:2008 :
Lippo di Calderara, May 19th 2009 ASSESSMENT OF ELECTRONIC AND ELECTRICAL EQUIPMENT RELATED TO HUMAN EXPOSURE RESTRICTIONS FOR ELECTROMAGNETIC FIELDS (0 HZ - 300 GHZ). Paola Chientaroli Quality Assurance Manager Datalogic Mobile S.r.l. Via S. Vitalino, 13 40012 - Lippo di Calderara Bologna - Italy 09 dichiara che declares that the dclare que le bescheinigt, da das Gert declare que el DL-MEMOR DL-MEMOR P/N: 944201017/DL-MEMOR P/N: 944201018 sono conformi alle Direttive del Consiglio Europeo sottoelencate:
are in conformity with the requirements of the European Council Directives listed below sont conformes aux spcifications des Directives de lUnion Europenne ci-dessous:
der nachstehend angefhrten Direktiven des Europischen Rats:
cumple con los requisitos de las Directivas del Consejo Europeo, segn la lista siguiente:
2004/108/EC and 1999/5/EC R&TTE Questa dichiarazione basata sulla conformit dei prodotti alle norme seguenti:
This declaration is based upon compliance of the products to the following standards:
Cette dclaration repose sur la conformit des produits aux normes suivantes:
Diese Erklrung basiert darauf, da das Produkt den folgenden Normen entspricht:
Esta declaracin se basa en el cumplimiento de los productos con la siguientes normas:
ETSI EN 301 489-1 V1.8.1, APRIL 2008 :
ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS
(ERM); ELECTROMAGNETIC COMPATIBILITY
(EMC) STANDARD FOR RADIO EQUIPMENT AND SERVICES;
PART 1: COMMON TECHNICAL REQUIREMENTS ETSI EN 301 489-17 V1.3.2, APRIL 2008 :
ETSI EN 301 489-7 V1.3.1, NOVEMBER 2005 : ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS
(ERM); ELECTROMAGNETIC COMPATIBILITY
(EMC) STANDARD FOR RADIO EQUIPMENT AND SERVICES;
PART 7: SPECIFIC CONDITIONS FOR MOBILE AND PORTABLE RADIO AND ANCILLARY EQUIPMENT OF DIGITAL CELLULAR RADIO TELECOMMUNICATIONS SYSTEMS (GSM AND DCS) ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS
(ERM); ELECTROMAGNETIC COMPATIBILITY
(EMC) STANDARD FOR RADIO EQUIPMENT; PART 17:
SPECIFIC CONDITIONS 2,4 GHZ WIDEBAND TRANSMISSION SYSTEMS, 5 GHZ HIGH PERFORMANCE RLAN EQUIPMENT AND 5,8 GHZ BROADBAND DATA TRANSMITTING SYSTEMS ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); WIDEBAND TRANSMISSION SYSTEMS;
DATA TRANSMISSION EQUIPMENT OPERATING IN THE 2,4GHZ ISM BAND AND USING WIDE BAND MODULATION TECHNIQUES;
HARMONIZED EN COVERING ESSENTIAL REQUIREMENTS UNDER ARTICLE 3.2 OF THE R&TTE DIRECTIVE ETSI EN 300 328 V1.7.1, OCTOBER 2006 :
FOR 1800 BANDS COVERING GLOBAL SYSTEM FOR MOBILE COMMUNICATIONS (GSM);
HARMONIZED EN FOR MOBILE STATIONS IN THE GSM 900 AND GSM ESSENTIAL REQUIREMENTS UNDER ARTICLE 3.2 OF THE R&TTE DIRECTIVE (1999/5/EC) INFORMATION TECHNOLOGY EQUIPMENT RADIO DISTURBANCE CHARACTERISTICS LIMITS AND METHODS OF MEASUREMENTS NFORMATION TECHNOLOGY EQUIPMENT IMMUNITY CHARACTERISTICS LIMITS AND METHODS OF MEASUREMENT INFORMATION TECHNOLOGY EQUIPMENT - SAFETY - PART 1
: GENERAL REQUIREMENTS ASSESSMENT OF ELECTRONIC AND ELECTRICAL EQUIPMENT RELATED TO HUMAN EXPOSURE RESTRICTIONS FOR ELECTROMAGNETIC FIELDS (0 HZ - 300 GHZ). PRODUCT STANDARD TO DEMONSTRATE THE COMPLIANCE OF MOBILE PHONES WITH THE BASIC RESTRICTIONS RELATED TO HUMAN EXPOSURE TO ELECTROMAGNETIC FIELDS (300 MHZ - 3 GHZ). Paola Chientaroli Quality Assurance Manager ETSI EN 301 511 V9.0.2, MARCH 2003 :
EN 55022:2006 (CLASS B) + A1:2007 :
EN 55024:1998 + A1:2001 + A2:2003 EN 60950-1:2001 + A11:2004 :
EN 62311:2008 :
EN 50360:2001 :
Lippo di Calderara, May 19th 2009
1 2 | Users Manual Addendum | Users Manual | 29.20 KiB | / June 02 2010 |
DL-Memor Regulatory Addendum radio frequency
(RF) energy set by RF EXPOSURE INFORMATION (SAR) This model device meets the governments requirements for exposure to radio waves. This device is designed and manufactured not to exceed the emission limits for exposure to the Federal Communications Commission of the U.S. Government. The exposure standard for wireless devices employs a unit of measurement known as the Specific Absorption Rate, or SAR. The SAR limit set by the FCC is 1.6W/kg. *Tests for SAR are conducted using standard operating positions accepted by the FCC with the device transmitting at its highest certified power level in all tested frequency bands. Although the SAR is determined at the highest certified power level, the actual SAR level of the device while operating can be well below the maximum value. This is because the device is designed to operate at multiple power levels so as to use only the poser required to reach the network. In general, the closer you are to a wireless base station antenna, the lower the power output. The highest SAR value for the model device as reported to the FCC are the following:
is 0.00412 W/kg. DL-Memor + 802.11g + BT models: for use at the head is 0.029 W/kg and when worn on the body, as described in the user guide,
(Body-worm measurements differ among device models, depending upon available enhancements and FCC requirements);
DL-Memor + EdgeA + BT models: for use at the head is 1 W/kg (GSM 850 Band) and 1.08 W/kg (GSM 1900 Band). When worn on the body, as described in the user guide, is 0.79W/kg (GSM 850 Band) and 0.198W/kg
(GSM 1900 Band). (Body-worm measurements differ among device models, depending upon available enhancements and FCC requirements). While there may be differences between the SAR levels of various devices and at various positions, they all meet the government requirement. 852000500 found under The FCC has granted an Equipment Authorization for this model device with all reported SAR levels evaluated as in compliance with the FCC RF exposure guidelines. SAR information on this model device is on file with the FCC and can be the Display Grant section of http://www.fcc.gov/oet/fccid after searching on the below FCC IDs:
FCC ID: U4G0030 for DL-Memor+802.11g+BT models;
FCC ID: U4G0033 for DL-Memor+EdgeA+BT models. This device is compliant with SAR for general population
/uncontrolled exposure limits in ANSI/IEEE C95.1-1999 and had been tested in accordance with the measurement methods and procedures specified in OET Bulletin 65 Supplement C. For body worn operation, this device has been tested and meets the FCC RF exposure guidelines for use with an accessory that contains no metal and the positions the handset a minimum of 1.5 cm from the body. Use of other enhancements may not ensure compliance with FCC RF exposure guidelines. If you do not use a body-worn accessory and are not holding the device at the ear, position the handset a minimum of 1.5 cm from your body when the device is switched on. INDUSTRY CANADA COMPLIANCE Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. This Class B digital apparatus complies with Canadian ICES-
003. Cet appareil numrique de la classe B est conforme la norme NMB-003 du Canada. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter. The County Code Selection feature is disabled for products marketed in the US/Canada. IMPORTANT NOTE:
IC Radiation Exposure Statement This general population/uncontrolled exposure limits in IC RSS-102 and had been tested in accordance with the measurement methods and procedures specified in IEEE 1528. This equipment should be installed and operated with minimum distance 1,5cm between the radiator & your body. compliant with SAR EUT for is CTIA COMPLIANCE Do not disassemble or open crush, bend or deform, puncture or shred. Do not modify or remanufacture, attempt to insert foreign objects into the battery, immerse or expose to water or other liquids, expose to fire, explosion or other hazard. Only use the battery for the system for which it is specified. Only use the battery with a charging system that has been qualified with the system per this standard. Use of an unqualified battery or charger may present a risk of fire, explosion, leakage, or other hazard. Do not short circuit a battery or allow metallic conductive objects to contact battery terminals. Replace the battery only with another battery that has been qualified with the system per this standard, IEEE-Std-1725-
2006. Use of an unqualified battery may present a risk of fire, explosion, leakage or other hazard. Promptly dispose of used batteries in accordance with local regulations. Battery usage by children should be supervised. Avoid dropping the phone or battery. If the phone or battery is dropped, especially on a hard surface, and the user suspects damage, take it to a service center for inspection. Improper battery use may result in a fire, explosion or other hazard. The device shall only be connected to products that bear the USB-IF logo or have completed the USB-IF compliance program. only applicable to EdgeA + Bluetooth models
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2009-12-24 | 1850.2 ~ 1909.8 | PCE - PCS Licensed Transmitter held to ear | Original Equipment |
2 | 2402 ~ 2480 | DSS - Part 15 Spread Spectrum Transmitter |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 2 | Effective |
2009-12-24
|
||||
1 2 | Applicant's complete, legal business name |
Datalogic S.r.l.
|
||||
1 2 | FCC Registration Number (FRN) |
0016179699
|
||||
1 2 | Physical Address |
Via S. Vitalino 13
|
||||
1 2 |
Calderara di Reno, N/A 40012
|
|||||
1 2 |
Italy
|
|||||
app s | TCB Information | |||||
1 2 | TCB Application Email Address |
T******@TIMCOENGR.COM
|
||||
1 2 | TCB Scope |
B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
|
||||
1 2 |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
|||||
app s | FCC ID | |||||
1 2 | Grantee Code |
U4G
|
||||
1 2 | Equipment Product Code |
0033
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 2 | Name |
R****** C********
|
||||
1 2 | Title |
Product Quality Leader
|
||||
1 2 | Telephone Number |
+39 0********
|
||||
1 2 | Fax Number |
+39 0********
|
||||
1 2 |
r******@datalogic.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 2 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 2 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 2 | If so, specify the short-term confidentiality release date (MM/DD/YYYY format) | 02/06/2010 | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 2 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 2 | Equipment Class | PCE - PCS Licensed Transmitter held to ear | ||||
1 2 | DSS - Part 15 Spread Spectrum Transmitter | |||||
1 2 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | POCKET-SIZED MOBILE COMPUTER | ||||
1 2 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 2 | Modular Equipment Type | Does not apply | ||||
1 2 | Purpose / Application is for | Original Equipment | ||||
1 2 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | Yes | ||||
1 2 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 2 | Grant Comments | Power listed is EIRP for part 24 and ERP for part 22. SAR compliance for body-worn operations is restricted to belt-clips, holsters, or similar accessories that have no metallic component in the assembly and which provide at least 1.5 cm separation between the device and the users body. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR levels are: Part 22: Body: 0.79W/kg, Head: 1.00W/kg; Part 24: Body: 0.20W/kg, Head: 1.08W/kg. This device contains functions that are not operational in U.S. Territories. This filing is only applicable for U.S. operations. | ||||
1 2 | Power listed is conducted. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. End-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. | |||||
1 2 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 2 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 2 | Firm Name |
Sporton International Inc.
|
||||
1 2 | Name |
A**** C********
|
||||
1 2 | Telephone Number |
886-3******** Extension:
|
||||
1 2 | Fax Number |
886-3********
|
||||
1 2 |
a******@sporton.com.tw
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 22H | 824.2 | 848.8 | 2.94 | 0.05 ppm | 244KGXW | ||||||||||||||||||||||||||||||||||
1 | 2 | 22H | 824.2 | 848.8 | 1.24 | 0.06 ppm | 240KG7W | ||||||||||||||||||||||||||||||||||
1 | 3 | 24E | 1850.2 | 1909.8 | 0.95 | 0.02 ppm | 244KGXW | ||||||||||||||||||||||||||||||||||
1 | 4 | 24E | 1850.2 | 1909.8 | 0.45 | 0.04 ppm | 240KG7W | ||||||||||||||||||||||||||||||||||
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
2 | 1 | 15C | 2402.00000000 | 2480.00000000 | 0.0020000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC