FHSS Module BT832X Ver1.04May2022 BT832X-HFSS is a powerful, highly flexible,BT832X using Nordic nRF52832 SoC. With an ARMCortexTM M4F MCU, available 512KB flash, 64KB RAM, embedded 2.4GHz multi-protocol transceiver, power amplifier, and an integrated PCB trace antenna. It allows faster time to market with reduced development cost. For applications needing limited number of IO pins, prototyping and production are easier using 16 castellated pins. Additional 24 LGA (Land Grid Array) pins provide access to 29 GPIOs of nRF52832. 2.4 GHz Frequency Hopping Spread Spectrum Transceiver Point-to-point, Point-to-multipoint, Peer-to-peer and Store & Forward Capabilities Specifications:
Nordic nRF52832 with ARM Cortex M4F. 20 channel CPU independent Programmable Complete RF solution with integrated antenna Peripheral Interconnect (PPI). Integrated DC-DC converter Quadrature Demodulator (QDEC) Serial Wire Debug (SWD) Nordic SoftDevice Ready 128-bit AES HW encryption 5 x 32 bits, 3 x 24 bits Real Time Counters Over-the-Air (OTA) firmware update
(RTC) Flash/RAM: 512KB/64KB Receiver Sensitivity: -96 dBm 29 GPIO pins 12 bit/200KSPS ADC TX power: +20 dBm Sizes: 15.0x28.0x1.9mm 3 SPI Master/Slave (8Mbps) Hybrid pins: 16 castellated and 24 LGA. Low power comparator Integrated high performance PCB trace Two 2-wire Master/Slave (I2C compatible) antenna with a power amplifier I2S audio interface Operation voltage: 1.8V to 3.6V UART (with CTS/RTS and DMA) Operation temperature: -40C to +85C Applications Mira Fitness/Sports Smart toys Connected appliances Lighting products IoT (Internet of Things) Sensors Home and building automation Long range equipment remote control Video and audio transmission 1 FHSS Module BT832X Ver1.04May2022 ModelSummaries module SoC Flash/RAM BT Antenna Range at 1Mbps FCC ID Canada IC ID Availability BT832X nRF52832-QFAA 512KB/64KB PCB trace Pending Pending BT832XE nRF52832-QFAA 512KB/64KB u.FL Pending Pending 2 FHSS Module BT832X Ver1.04May2022 Table Of Contents 1. Introduction .................................................................................................................................................... 4 2. Codes Development Using Nordic Tools ...................................................................................................... 4 Easy, fast and safe code development ............................................................................................................... 4 Mira............................................................................................................... !
Development Tools .............................................................................................................................................. 5 3. Product Overview ........................................................................................................................................... 6 Block Diagram ...................................................................................................................................................... 6 Mechanical Drawings ........................................................................................................................................... 9 Pin Assignments of BT832X ................................................................................................................................ 9 Host PCB Layout Guidelines ............................................................................................................................. 11 Mounting BT832X on the Host PCB .................................................................................................................. 12 Control Skyworks Power Amplifier .................................................................................................................... 14 4. AT Commands ............................................................................................................................................. 16 Brief description of AT commands ..................................................................................................................... 16 Command mode ................................................................................................................................................. 17 Data Mode .......................................................................................................................................................... 19 Communicating with a PC ................................................................................................................................. 19 5. Evaluation Boards and Reference Designs ................................................................................................ 19 Schematics and Gerber Files ............................................................................................................................ 19 Evaluation Board EV BT832X V3 Schematics .................................................................................................. 21 6. Miscellaneous .............................................................................................................................................. 22 Soldering Temperature-Time Profile for Re-Flow Soldering ............................................................................. 22 Cautions, Design Notes, and Installation Notes ................................................................................................ 22 Packaging ........................................................................................................................................................... 25 FCC Label .......................................................................................................................................................... 25 7. Contact Us ................................................................................................................................................... 27 3 FHSS Module BT832X Ver1.04May2022 1. Introduction BT832X-FHSS is powerful, highly flexible, ultra low power Bluetooth Low Energy (BLE) modules using Nordic nRF52832 SoCs. With an ARMCortexTM M4F MCU, available 512KB flash, 64KB RAM, embedded 2.4GHz multi-protocol transceiver, power amplifier, and an integrated antenna, it allows faster time to market with reduced development cost. The following is a block diagram of BT832X. Antenna circuit and main clock are integrated. All 32 GPIOs of nRF52832 can be accessed from main board. For lower power consumption at idle state, an optional 32.768 kHz crystal can be on board. 2. Codes Development Using Nordic Tools Development tools by Nordic and other third party development tools recommended by Nordic should be used . Easy, fast and safe code development Nordic development environment for nRF52832 offers a clean separation between application code development and embedded protocol stacks. This means compile, link and run time dependencies with the embedded stack and associated debugging challenges are removed. The Bluetooth low energy and ANT stack is a pre-compiled binary, leaving application code to be compiled stand-alone. The embedded stack interface uses an asynchronous and event driven model removing the need for RTOS frameworks. 4 FHSS Module BT832X Ver1.04May2022 Mira Please refer to the online documentation https://docs.lumenrad.io/miraos/2.6.2/
Development Tools Nordic Semiconductor provides a complete range of hardware and software development tools for the nRF52 Series devices. nRF52 DK board is recommended for firmware development. Nordic software development tools can be downloaded from the following webpage. http://infocenter.nordicsemi.com/index.jsp?topic=/com.nordic.infocenter.nrf52/dita/nrf52/development/nrf5 2_dev_kit.html&cp=1_1 5 FHSS Module BT832X Ver1.04May2022 3. Product Overview Brief description of nRF52832 SoC is provided. For full description of the SoC, please download from Nordic Semiconductor website. https://www.nordicsemi.com/eng/Products Block Diagram 6 FHSS Module BT832X Ver1.04May2022 The following is a block diagram of Nordic nRF52832 SoC. The 32 bit ARM Cortex M4F MCU with hardware supports for DSP instructions and floating point operations, code density and execution speed are higher than other Cortex M MCU. The Programmable Peripheral Interconnect (PPI) system provides a 20-channel bus for direct and autonomous system peripheral communication without CPU intervention. This brings predictable latency times for peripheral to peripheral 7 FHSS Module BT832X Ver1.04May2022 interaction and power saving benefits associated with leaving CPU idle. The device has 2 global power modes ON/OFF, but all system blocks and peripherals have individual power management control which allows for an automatic switching RUN/IDLE for system blocks based only on those required/not required to achieve particular tasks. The radio supports Bluetooth low energy and ANT. Output power is scalable from a maximum of +20dBm down to -4 dBm in 4dB steps. 8 FHSS Module BT832X Ver1.04May2022 Mechanical Drawings The followings are mechanical drawings of BT832X. Two types of pins are available to meet different application requirements. 16 castellated pins for application needing limited number of IOs. SMT equipment is not required for soldering castellated pins. 24 LGA (Land Grid Array) pins to access 29 GPIOs of nRF52832 when needed. 3 GPIO pins are used to control SKY66112 power amplifier. BT832X Mechanical drawing Pin Assignments of BT832X The followings are BT832X pin assignment. Pin functions are in a table in next section. Please refer to Nordic nRF52832 Product Specifications for detailed descriptions and features supported. 9 FHSS Module BT832X Ver1.04May2022 http://infocenter.nordicsemi.com/pdf/nRF52832_PS_v1.1.pdf BT832X pin# pin name 1 P26/SDA 2 P27/SCL 3 NC 4 NC 5 P02/AIN0 6 P03/AIN1 7 P09 8 P10 9 VDD 10 GND 11 P13 12 P18 13 P20 14 P021/RESET 15 SWDCLK 16 SWDIO A0 GND A1 P28 A2 P29 A3 P04 A4 P05 A5 P07 B0 GND B1 P25 B2 P30 B3 P31 B4 NC B5 P08 C0 GND C1 P24 C2 P22 C3 NC C4 P15 C5 P12 D0 GND D1 P23 nRF52832 pin#
pin name 38 P0.26 39 P0.27 2 P0.00/XL1 3 P0.01/XL2 4 P0.02/AIN0 5 P0.03/AIN1 11 P0.09 12 P0.10 13 VDD 45 VSS 16 P0.13 21 P0.18 23 P0.20 24 P0.21/RESET 25 SWDCLK 26 SWDIO 45 VSS 40 P0.28/AIN4 41 P0.29/AIN5 6 P0.04/AIN2 7 P0.05/AIN3 9 P0.07 45 VSS 37 P0.25 42 P0.30 43 P0.31 8 P0.06 10 P0.08 45 VSS 29 P0.24 27 P0.22 20 P0.17 18 P0.15 15 P0.12 45 VSS 28 P0.23 Descriptions GPIO, configured as I2C SDA on EV-BT832 GPIO, configured as I2C SCL on EV-BT832 32.768kHz crystal on module 32.768kHz crystal on module GPIO, Analog input GPIO, Analog input GPIO, GPIO, DC supply 1.7V to 3.6V Ground GPIO GPIO GPIO GPIO, configurable as RESET pin Serial Wire Debug clock input Serial Wire Debug I/O Ground GPIO, Analog input GPIO, Analog input GPIO, Analog input GPIO, Analog input GPIO Ground GPIO GPIO GPIO No Connect, used for SKY66112 on module GPIO Ground GPIO GPIO No Connect, used for SKY66112 on module GPIO GPIO Ground GPIO 10 FHSS Module BT832X Ver1.04May2022 No Connect, used for SKY66112 on module D2 NC D3 P16 D4 P14 D5 P11 F0 GND F1 GND F2 GND F3 GND Pin Functions 22 P0.19 19 P0.16 17 P0.14 14 P0.11 GPIO GPIO GPIO Ground Ground Ground Ground Host PCB Layout Guidelines For the best Bluetooth range performance, we recommend using library component extracted from EV BT840F V3 Gerber files. It can be downloaded from http://www.fanstel.com/download-document/. There are 21 additional BT840F pins not used by BT832X. These pins are in solid dark color below. As much ground plane under BT832X, on top side of host PCB as possible. Use EV BT840F/EV BT832X Gerber files as an example. We recommend 4 or more layers for the host PCB. The top side shall be mostly ground. Signal routing shall be in the middle layers. 11 FHSS Module BT832X Ver1.04May2022 Mounting BT832X on the Host PCB The following figure shows recommended mounting of BT832X module on the host PCB. For the best Bluetooth range performance, the antenna area of module shall extend 11.2 mm outside the edge of host PCB board, or 11.2 mm outside the edge of a ground plane. Except required for pin connection, ground plane to cover top layer of main board. We recommend multiple layers main board avoiding routing on the top layer. For the best Bluetooth range performance, keep all external metal away from the antenna area. 12 FHSS Module BT832X Ver1.04May2022 For guideline of trace design, contact us 13 FHSS Module BT832X Ver1.04May2022 Control Skyworks Power Amplifier BT832X uses SKYWORKS SKY66112-11 power amplifier. The connection diagram with control signal pins is below. A firmware configuration example to control Skyworks SKY66112 power amplifier is below. This firmware file, SKY66112_PAconfig.txt can be downloaded from http://www.fanstel.com/download-document/.
//PCA10040.h
//set the clock
#define NRF_CLOCK_LFCLKSRC {.source = NRF_CLOCK_LF_SRC_SYNTH, \
.rc_ctiv = 0, \
.rc_temp_ctiv = 0, \
.xtal_accuracy = NRF_CLOCK_LF_XTAL_ACCURACY_250_PPM}
14 FHSS Module BT832X Ver1.04May2022
//main.c
//config the PA/LNA
#ifdef APP_PA_LAN
#define APP_PA_PIN 17
#define APP_LNA_PIN 19
#define APP_CPS_PIN 6
#define APP_AMP_PPI_CH_ID_SET 0
#define APP_AMP_PPI_CH_ID_CLR 1
#define APP_AMP_GPIOTE_CH_ID 0 static void pa_lna_setup(void)
uint32_t err_code;
nrf_gpio_cfg_output(APP_CPS_PIN);
nrf_gpio_pin_clear(APP_CPS_PIN); //enable nrf_gpio_cfg_output(APP_PA_PIN);
nrf_gpio_pin_clear(APP_PA_PIN); //
nrf_gpio_cfg_output(APP_LNA_PIN);
nrf_gpio_pin_clear(APP_LNA_PIN); //
staticble_opt_tpa_lna_opts = {
.common_opt = {
.pa_lna = {
15 FHSS Module BT832X Ver1.04May2022
.pa_cfg = {
.enable = 1,
.active_high = 1,
.gpio_pin = APP_PA_PIN
.lna_cfg = {
.enable = 1,
.active_high = 1,
.gpio_pin = APP_LNA_PIN
.ppi_ch_id_set = APP_AMP_PPI_CH_ID_SET,
.ppi_ch_id_clr = APP_AMP_PPI_CH_ID_CLR,
.gpiote_ch_id = APP_AMP_GPIOTE_CH_ID NRF_GPIO->DIRSET |= (1 << APP_PA_PIN) | (1 << APP_LNA_PIN) ;
err_code = sd_ble_opt_set(BLE_COMMON_OPT_PA_LNA, &pa_lna_opts);
APP_ERROR_CHECK(err_code);
#endif 4. AT Commands BT832X module is available with firmware supporting AT commands. Part number is BT832X-AT. Brief description of AT commands
Each command line consists of a prefix, a body and a terminator.
All command lines begin with the prefix AT (ASCII 065, 084) or at (ASCII 097, 116). 16 FHSS Module BT832X Ver1.04May2022
The body is a string of characters in the ASCII range 032-255. Control characters other than <CR>
(carriage return; ASCII 013) and <BS> (back space; ASCII 008) in a command line are ignored.
The terminator is <CR>.
There is no distinction between upper-case and lower-case characters. A command line can have a maximum length of 80 characters. It is automatically discarded if the input is longer. Corrections are made
AT command is case-insensitive, following /r/n for end code.
The default baud rate is 9600 one stop bit and no parity Command mode When P0.03 of nRF52832 (pin 6 of BT832X) is pulled high, it is set to AT command mode. In AT command mode, the host processor communicates with the processor on BT832X. Command Response Parameter example AT OK or FAIL AT+RESET OK or FAIL AT+VERSION?
OK
+VERSION:<param>
AT+NAME?
+NAME:<param> OK AT+NAME=<param>
OK or FAIL none none Software version number Device name AT/r/n OK/r/n OK/r/n AT+RESET/r/n AT+VERSION?/r/n
+VERSION140804 OK/r/n AT+NAME?/r/n
+NAME:EZPro OK/r/n AT+NAME=Fanstel/r/n Device name Or AT_Name=Fanstel/r/n OK/r/n Baud rate, AT+UART?/r/n Stop bit,
+UART:115200,1,0 Parity OK/r/n AT+UART=115200/r/n OK/r/n AT+UART?
+UART:<param>,<param2>,<param3>
OK AT+UART=<parm>
+UART:<parm>
Baud rate
+UART:115200,1,0 17 FHSS Module BT832X Ver1.04May2022 9600 default 1200 2400 4800 19200 38400 57600 115200 230400 460800 921600 1000000 AT+REGISTER/r/n OK/r/n AT+QUITREGISTER/r/n OK/r/n AT+RX?/r/n
+NAME:EZPro/r/n
+UART:115200,1,1/r/n
+ADDR:abb5:cd:604ace
/r/n AT+DEFAULT/r/n AT+RFPW?/r/n
+RFPW:-4 OK/r/n 0:+4 2:-4 3:-8 AT+ADDR?
+ADDR:<param> OK Device MAC address AT+ADDR?/r/n
+ADDR:abb5:cd:604ace OK/r/n AT+REGISTER OK or FAIL AT+QUITREGISTER OK or FAIL AT+RX?
+Name:<parm>
+UART:<parm>
+ADDR:<parm>
none none none AT+DEFAULT OK or FAIL none OK/r/n AT_RFPW?
+RFPW:parm
+4~-8 1:+0 default 18 FHSS Module BT832X Ver1.04May2022 AT_RFPW=<parm>
OK or FAIL
+4~-8 AT+RFPW= 1/r/n OK/r/n 0:+4 1:+0 2:-4 3:-8 P00-P05 AT+PIO=05, 0\r\n 1=High ,0=l ow OK/r/n P00-P05 AT+PIS=05, 1\r\n 1=output, 0=input OK/r/n AT+PIO=<param><param1> OK or FAIL AT+PIS=<param><param1> OK or FAIL Data Mode When P0.03 of nRF52832 (pin 6 of BT832X) is pulled low, it is set to data mode. In data model, BT832X provides transparent data transfer between the host processor and a remote device, for example, a smartphone. Communicating with a PC A quick and easy way to evaluate BT832X is to use a PC as the host processor. Connect the development board EV-BT832X to a PC with an USB cable. Then,
Set S1, BT832X is set to command mode. PC will communicate with BT832X.
Set switch S1 to the other position, BT832X is set to data mode. PC will communicate with a remote device through BT832X Bluetooth wireless connection. Docklight is a testing, analysis and simulation tool for serial communication protocols (RS232, RS485/422 and others). It allows you to monitor the communication between two serial devices or to test the serial communication of a single device. Docklight significantly increases productivity in a broad range of industries, including automation and control, communications, automotive, equipment manufacturers, and embedded /
consumer products. Docklight is easy to use and runs on almost any standard PC using Windows 10, Windows 8, Windows 7, Windows Vista or Windows XP operating system. Docklight software can be downloaded from the following:
http://www.docklight.de/download_en.htm 5. Evaluation Boards and Reference Designs Schematics and Gerber Files Evaluation board schematics and Gerber files can be downloaded from 19 FHSS Module BT832X Ver1.04May2022 http://www.fanstel.com/download-document/
Evaluation board can be used as a reference design for using modules. EV BT840F V3 is designed for the BT840F soldering pads with 61 pins. When a BT832X is mounted on an EV BT840F, it becomes an EV BT832X. These 21 pins in solid dark color are not connected when a BT832X is mounted. BT832X has the same soldering pad footprint as BT832 or BT832F. Library component for BT832 and BT840F can be used. For the Bluetooth range performance, BT840F library component shall be used for your BT832X design. 20 FHSS Module BT832X Ver1.04May2022 Evaluation Board EV BT832X V3 Schematics EV BT832X V3 evaluation board is developed for BT840F and BT832X. It can be used for BT832 and BT832F. Pins in solid color are used only for BT840F. On EV BT832X, SW5 must be set to OFF and use on-board 32.768 KHz clock. Around U1 BT840 (832) red color pin functions are for BT840F and blue color pin functions are for BT832X. Additional feature enhancements for version V3 evaluation board:
1. It has the same foot print as Arduino Uno R3. Additional connectors are added for connection to extra GPIO pins of BlueNor modules. many UNO R3 compatible shields. 2. EV BT832X is not an UNO R3 compatible board. You can use Nordic develop tools to develop firmware for 3. SW5 must be set to OFF and use internal 32.768 kHz crystal or oscillator. 4. Portable smartphone charger can be used to power this board. The circuitry to the left of micro USB connector, J16 produces periodic load to prevent portable smartphone charger from shutting down. 21 FHSS Module BT832X Ver1.04May2022 5. Miscellaneous Soldering Temperature-Time Profile for Re-Flow Soldering Maximum number of cycles for re-flow is 2. No opposite side re-flow is allowed due to module weight. Cautions, Design Notes, and Installation Notes Failure to follow the guidelines set forth in this document may result in degrading of the products functions and damage to the product. DesignNotes
(1) Follow the conditions written in this specification, especially the control signals of this module.
(2) The supply voltage has to be free of AC ripple voltage (for example from a battery or a low noise regulator output). For noisy supply voltages, provide a decoupling circuit (for example a ferrite in series connection and a bypass capacitor to ground of at least 47uF directly at the module).
(3) This product should not be mechanically stressed when installed.
(4) Keep this product away from heat. Heat is the major cause of decreasing the life of these products. spikes.
(5) Avoid assembly and use of the target equipment in conditions where the products' temperature may exceed the maximum tolerance.
(6) The supply voltage should not be exceedingly high or reversed. It should not carry noise and/or 22 FHSS Module BT832X Ver1.04May2022
(7) this product away from other high frequency circuits. NotesonAntennaandPCBLayout
(1) Dont use a module with internal antenna inside a metal case.
(2) For PCB layout:
Avoid running any signal line below module whenever possible, No ground plane below antenna, If possible, cut-off the portion of main board PCB below antenna. Installation Notes
(1) Reflow soldering is possible twice based on the time-temperature profile in this data sheets. Set up the temperature at the soldering portion of this product according to this reflow profile.
(2) Carefully position the products so that their heat will not burn into printed circuit boards or affect the other components that are susceptible to heat.
(3) Carefully locate these products so that their temperatures will not increase due to the effects of heat generated by neighboring components.
(4) If a vinyl-covered wire comes into contact with the products, then the cover will melt and generate toxic gas, damaging the insulation. Never allow contact between the cover and these products to occur.
(5) This product should not be mechanically stressed or vibrated when reflowed.
(6) If you want to repair your board by hand soldering, please keep the conditions of this chapter.
(7) Do not wash this product.
(8) Refer to the recommended pattern when designing a board.
(9) Pressing on parts of the metal cover or fastening objects to the metal will cause damage to the
(10) For more details on LGA (Land Grid Array) soldering processes refer to the application note. UsageConditionNotes
(1) Take measures to protect the unit against static electricity. If pulses or other transient loads (a large load applied in a short time) are applied to the products, check and evaluate their operation before assembly on the final products. Do not use dropped products. Do not touch, damage or soil the pins. Follow the recommended condition ratings about the power supply applied to this product. Electrode peeling strength: Do not add pressure of more than 4.9N when soldered on PCB unit.
(2)
(3)
(4)
(5) 23 FHSS Module BT832X Ver1.04May2022
(6) Pressing on parts of the metal cover or fastening objects to the metal cover will cause damage.
(7) These products are intended for general purpose and standard use in general electronic equipment, such as home appliances, office equipment, information and communication equipment. Storage Notes
(1) The module should not be stressed mechanically during storage.
(2) Do not store these products in the following conditions or the performance characteristics of the product, such as RF performance will be adversely affected:
Storage in salty air or in an environment with a high concentration of corrosive gas. Storage in direct sunlight Storage in an environment where the temperature may be outside the range specified. Storage of the products for more than one year after the date of delivery storage period.
(3) Keep this product away from water, poisonous gas and corrosive gas.
(4) This product should not be stressed or shocked when transported.
(5) Follow the specification when stacking packed crates (max. 10). Safety Conditions These specifications are intended to preserve the quality assurance of products and individual components. Before use, check and evaluate the operation when mounted on your products. Abide by these specifications, without deviation when using the products. These products may short-circuit. If electrical shocks, smoke, fire, and/or accidents involving human life are anticipated when a short circuit occurs, then provide the following failsafe functions, as a minimum.
(1) Ensure the safety of the whole system by installing a protection circuit and a protection device.
(2) Ensure the safety of the whole system by installing a redundant circuit or another system to prevent a dual fault causing an unsafe status. Other Cautions
(1) This specification sheet is copyrighted. Reproduction of this data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices.
(2)
(3) Do not use the products for other purposes than those listed. Be sure to provide an appropriate failsafe function on your product to prevent an additional damage that may be caused by the abnormal function or the failure of the product.
(4) This product has been manufactured without any ozone chemical controlled under the Montreal Protocol. 24 FHSS Module BT832X Ver1.04May2022
(5) These products are not intended for other uses, other than under the special conditions shown below. Before using these products under such special conditions, check their performance and reliability under the said special conditions carefully to determine whether or not they can be used in such a manner. In liquid, such as water, salt water, oil, alkali, or organic solvent, or in places where liquid may splash. In direct sunlight, outdoors, or in a dusty environment In an environment where condensation occurs. In an environment with a high concentration of harmful gas.
(6) If an abnormal voltage is applied due to a problem occurring in other components or circuits, replace these products with new products because they may not be able to provide normal performance even if their electronic characteristics and appearances appear satisfactory.
(7) When you have any question or uncertainty, contact Fanstel. Packaging Production modules are delivered in reel, 1000 modules in each reel. FCC LABEL The Original Equipment Manufacturer (OEM) must ensure that the OEM modular transmitter must be labeled with its own FCC ID number. This includes a clearly visible label on the outside of the final product enclosure that displays the contents shown below. If the FCC ID is not visible when the equipment is installed inside another device, then the outside of the device into which the equipment is installed must also display a label referring to the enclosed equipment The end product with this module may subject to perform FCC part 15 unintentional emission test requirement and be properly authorized. This device is intended for OEM integrator only. 25 FHSS Module BT832X Ver1.04May2022 7466 E. Monte Ctisto Ave. Scottsdale AZ 85260 10F-10, 79 Xintai Wu Road Xizhu, New Taipei City, Taiwan 22101 79 10 10, 22101 6.Contact Us United States:
Fanstel Corp. Tel. 1 480-948-4928 Fax. 1-480-948-5459 Email: module@fanstel.com Website: www.fanstel.com Taiwan:
Fanstel Corp. Tel. 886-2-2698-9328 Fax. 886-2-2698-4813 Email: tp@fanstel.com Website: www.fanstel.com China:
Fanstel Technologies Corp. 11 Jiale Street Tel. 86-755-8409-0928 Fax. 86-755-8409-0973 QQ. 3076221086 Email: sz@fanstel.com Website: www.fanstel.com Ping-Dih, Long-Gang, Shen Zhen, GD 518117
() 11 26 FHSS Module BT832X Ver1.04May2022 Federal Communications Commission (FCC) Statement 15.21 You are cautioned that changes or modifications not expressly approved by the part responsible for compliance could void the users authority to operate the equipment. 15.105(b) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1) this device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation of the device. FCC RF Radiation Exposure Statement 1) This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. 2) This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body. This equipment should be installed. Note: The end product shall has the words Contains Transmitter Module FCC ID: X8WBT832XH 27 FHSS Module BT832X Ver1.04May2022 Canada, Industry Canada (IC) This Class B digital apparatus complies with Canadian ICES-003 Cet appareil numrique de classe B est conforme la norme NMB-003. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the Le present appareil est conforme aux CNR d'Industrie Canada applicables auxappareils radio exempts de licence.L'exploitation est autorise aux deux conditions suivantes:
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage adiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. Conformit des appareils de radiocommunication aux limites d'exposition humaine aux radiofrquences (CNR-102) L'ordinateur utilise des antennes intgrales faible gain qui n'mettent pas un champ lectromagntique suprieur aux normes imposes par Sant Canada pour la population. Consultez le Code de scurit 6 sur le site Internet de Sant Canada l'adresse suivante : http://www.hc-sc.gc.ca/
L'nergie mise par les antennes relies aux cartes sans fil respecte la limite d'exposition aux radiofrquences telle que dfinie par Industrie Canada dans la clause 4.1 du document CNR-102, version 4. Caution: Exposure to Radio Frequency Radiation. To comply with RSS 102 RF exposure compliance requirements, a separation distance of at least 20 cm must be maintained between the antenna of this device and all persons. Pour se conformer aux exigences de conformit CNR 102 RF exposition, une distance de sparation d'au moins 20 cm doit tre maintenue entre l'antenne de cet appareil et toutes les personnes.
(Modular approval) End Product Labeling:
The final end product must be labeled in a visible area with the following: Contains IC: 4100A-BT832XH. Le produit final doit tre tiquet dans une zone visible avec ce qui suit Contient IC : 4100A-BT832XH 28 FHSS Module BT832X Ver1.04May2022 OEM statement The Original Equipment Manufacturer (OEM) must ensure that the OEM modular transmitter must be labeled with its own FCC ID number. This includes a clearly visible label on the outside of the final product enclosure that displays the contents shown below. If the FCC ID is not visible when the equipment is installed inside another device, then the outside of the device into which the equipment is installed must also display a label referring to the enclosed equipment. The end product with this module may subject to perform FCC part 15B unintentional emission test requirement and be properly authorized while installation to host(s), and platform, and integrator are obligated to have its manual or instruction with the related compliance warning to end users. This device is intended for OEM integrator only The end product with this module may be subject to re-evaluate RF exposure as per 47CFR 2.1091, and 2.1093 if antenna or usage, including co-located usage of other transmitters, of the subsequent installation are changed. This radio transmitter has been approved by FCC/Innovation, Science and Economic Development Canada to operate with the antenna types listed below, with the maximum permissible gain indicated. Antenna types not included in this list that Have a gain greater than the maximum gain indicated for any type listed are strictly prohibited for use with this device. PCB Trae antennas: 2.34 dBi dipole antennas: 6.15dBi Cet metteur radio a t approuv par FCC/Innovation, Science et Dveloppement conomique Canada pour fonctionner avec les types d'antennes rpertoris ci-dessous, avec le gain maximal autoris indiqu. Les types d'antenne non inclus dans cette liste qui ont un gain suprieur au gain maximum indiqu pour tout type rpertori sont strictement interdits pour une utilisation avec cet appareil. Antennes PCB Trace : 2.34 dBi Antennes diples : 6.15 dBi 29