Installation Guide WIT100 Sensor Wireless Integrated Thread Sensor STOP BEFORE YOU BEGIN Read these instructions completely and carefully. RISK OF ELECTRIC SHOCK Turn power off before inspection, installation or removal RISK OF FIRE Follow all relevant IEC or UL instructions and local building codes WARNING In case of Digital bus miswiring mains can present on the device. Make sure all electricity switched of before inspection. IMPORTANT To ensure the product warranty is valid, please ensure all installation instructions and environmental conditions for storage and operation are complied with. Only GE trained contractors can install the product. FCC / IC COMPLIANCE STATEMENTS This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This device complies with Industry Canada license exempt RSS standards. Operation is subject to the following two conditions:
This device may not cause harmful interference, and This device must accept any interference received, including interference that may cause undesired operation. Cet appareil est conforme aux normes RSS exemptes de licence de Industrie Canada. Son fonctionnement est soumis aux deux conditions suivantes:
Cet appareil ne doit pas provoquer d'interfrences et Cet appareil doit accepter toute interfrence, y compris celles pouvant causer un mauvais fonctionnement de l'appareil. To satisfy FCC/ISED RF exposure requirements a separation distance of 20 cm or more must be maintained between the antenna of this device and persons during operation. Operation at closer than 20cm is not permitted Pour tre conforme aux limites dexposition aux ondes RF des normes FCC/ISED, une distance de sparation dau moins 20 cm doit tre main-
tenue entre lantenne de cet appareil et toute personne pendant son opration. Mettre en opration cet appareil a une distance plus rappro-
che que 20 cm nest pas permis. Product overview The Wireless Integrated Therad sensor (WIT100) is a small-size, luminaire-integrated sensor with wireless communication, using the cutting-edge Thread protocol. This is based on the 802.15.4 standard and guarantees a secure and reliable communication between the luminaires in the room. Using the WIT100 sensor in each luminaire provides a state-of-the-art distributed lighting control based on the built-in motion sensing and daylight harvesting functionalities. This sensed information is then shared between all luminaires. The control of the luminaire is carried out through the DALI 2.0 digital bus between the output of the sensor and the control input of the luminaires LED driver. The DALI bus also provides the necessary supply power for the sensor, no any additional wiring and auxiliary power supply is required. This and the wireless communication help minimizing the installation costs. Besides the automatic operation of the system it is also possible to adjust preferred dimming levels manually through Currents energy-harvesting wireless switches. These switches do not require wires for communication, but they even use the mechanical energy of pushing the button to generate the necessary power for the electronics. The configuration of the system is done in a very easy way using through Currents Bluetooth-based iOS application. Techical data Key functions Dimensions Weight Current consumption Sensor type Operating Environment Status indicator Connections Mounting Recomented mounting height Warranty Product Certifications 58,5 x D35mm (2,303xD1,378 inch) + connected cable 15g Max 8mA (without digital communication) @ Max. 20V DC Passsive infrared (PIR) sensor (for motion), light sensor 0C to 45C / IP 20 Indoor, dry location. Network LED (amber): Network joined; Installation test Cable connection to the Driver or Interface module. Easy screwless installation to a D22mm (0,866 inch) cut hole. 3m 5 years E486320 FCC ID: PUU-WIT100 IC ID: 10798A-PUUWIT100 Product availability SKU TBD Notes Description Wireless Integrated Thread Sensor Article No. WIT100 Purpose of the Control Method of Mounting Control Type of action and additional features Control Pollution Degree Software Class and Structure Maximum Interconnection cables length Operating Control Independently Mounted Control for panel mounting Type 1 2 Class A 3 m Dimensions Sensor pattern Cable connection to driver Connect the WIT100 Sensor Digital bus line with a TE770340 / TE350628 connector to the bellow drivers and interface module:
Connected Indoor Driver (CID): limited compatibility to allow proper operation of fixture (OFF, backround level dim and task level lighting) and OTA Philips Sensor Ready driver (SR): compatibility desirable but not required Leedarson 0-10V/DALI interface module: ON/OFF and dimming commands only (no Fault Reporting, no VLC, no Dimming Curve Change, no 1% diming, partial UL924) Cable from Driver/Interface module www.currentbyge.com All trademarks are the property of their respective owners. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions. Current, powered by GE is a business of the General Electric Company. 2016 GE. WIT100 Sensor Install Manual (GE2033-0758 / SAPXXXXXXXX)