Grandstream Networks, Inc. 126 Brookline Ave, 3rd Floor Boston, MA 02215. USA Tel : +1 (617) 566 - 9300 Fax: +1 (617) 249 - 1987 www.grandstream.com For Certification, Warranty and RMA information, please visit www.grandstream.com GWN7800 Series Entreprise Layer 2+
Managed Network Switch Quick Installation Guide EN OVERVIEW The GWN7800 series are Layer 2+ managed network switches that allow small-to-medium enterprises to build scalable, secure, high per-
formance, and smart business networks that are fully manageable. It supports advanced VLAN for flexible and sophisticated traffic segmenta-
tion, advanced QoS for automated detection & prioritization of latency sensitive voice/video traffic, IGMP Snooping for network performance optimization, and comprehensive security capabilities against potential attacks. The PoE models provide smart dynamic PoE output to power IP phones, IP cameras, Wi-Fi access points and other PoE endpoints. The GWN7800 series can be managed in a number of ways, including the local network controller embedded in the GWN7800 series switch, any GWN7000 series router with integrated local master, Grandstreams free on-premise network management software (GWN Manager), as well as Grandstreams cloud network management platform (GWN.Cloud). The GWN7800 series are best value enterprise-grade managed network switches for small-to-medium businesses. PRECAUTIONS Do not attempt to open, disassemble, or modify the device. Do not expose this device to temperature outside range of 0 C to 45 C for operation and -10 C to 60 C for storage. Do not expose the GWN7800 to environments outside of the following hu-
midity range: 10-90% RH (non-condensing) for operation and 5-95% RH
(non-condensing) forstorage. Do not power cycle your GWN7800 during system boot up or firmware up-
grade. You may corrupt firmware images and cause the unit to malfunction. PACKAGE CONTENTS GWN7800 Series Switch 1x 1.2m (10A) AC Cable 1x 25cm Ground Cable 4x Rubber Footpads 8x Screws (KM 3*6) 2x Rack Mounting Kits or 1x Console Cable
(Optional) 1x Power Cord Anti-
Trip (Optional) 1x Quick Installation Guide PORTS & LED Indicator GWN7801/GWN7801P 1 2 8 5 3 4 6 7 9 No. Port & LED Description 1 2 3 4 5 6 7 8 9 Port 1-8 8x Ethernet RJ45 (10/100/1000Mbps), used for connecting terminals. Note: GWN7801P Ethernet ports support PoE and PoE+. 1-8 Ethernet ports LED indicators Port SFP1/2 2x 1000Mbps SFP ports SFP 1/2 Console RESET SFP ports LED indicators 1x Console port, used for connecting managing PC Factory Reset pinhole. Press for 5 seconds to reset factory default settings SYS System LED indicator 100-240VAC 50-60Hz Power socket Lighting protection grounding post
~ 1 ~
~ 2 ~
GWN7802/GWN7802P GWN7803/GWN7803P 1 2 3 5 6 7 4 1 2 3 5 6 7 4 10 8 8 GWN7802 9 9 GWN7802P No. Port & LED Description 1 Port 1-16 16x Ethernet RJ45 (10/100/1000Mbps), used for connecting terminals. Note: GWN7802P Ethernet ports support PoE and PoE+. 2 3 4 5 6 7 8 9 1-16 Ethernet ports LED indicators Port SFP1/2/3/4 4x 1000Mbps SFP ports SFP 1/2/3/4 SFP ports LED indicators Console RESET 1x Console port, used for connecting managing PC Factory Reset pinhole. Press for 5 seconds to reset factory default settings SYS System LED indicator 100-240VAC 50-60Hz Power socket Lighting protection grounding post 10 Fan 1x Fan
~ 3 ~
8 GWN7803 10 9 9 8 GWN7803P No. Port & LED Description 1 Port 1-24 24x Ethernet RJ45 (10/100/1000Mbps), used for connecting terminals. Note: GWN7803P Ethernet ports support PoE and PoE+. 2 3 4 5 6 7 8 9 1-24 Ethernet ports LED indicators Port SFP1/2/3/4 4x 1000Mbps SFP ports SFP 1/2/3/4 SFP ports LED indicators Console RESET 1x Console port, used for connecting managing PC Factory Reset pinhole. Press for 5 seconds to reset factory default settings SYS System LED indicator 100-240VAC 50-60Hz Power socket Lighting protection grounding post 10 Fan 2x Fans
~ 4 ~
LED Indicator LED Indicator Status Description Off Solid green Power off Booting Flashing green Upgrade System Indicator Solid blue Normal use Flashing blue Privisioning Solid red Upgrade failed Flashing red Factory reset Port Indicator Off Solid green For all ports, port off For SFP ports, port failure Port connected and there is no activity Flashing green Port connected and data is transferring Solid yellow Ethernet port connected and PoE powered Flashing yellow Ethernet port connected, data is transferring and PoE powered Alternately flashing yellow and green Ethernet port failure POWERING & CONNECTING Grounding the Switch 1. Remove the ground screw from the back of switch, and connect one end of the ground cable to the wiring terminal of switch. 2. Put the ground screw back into the screw hole, and tighten it with a screwdriver. 3. Connect the other end of the ground cable to other device that has been grounded or directly to the terminal of the ground bar in the equipment room. Ground Terminal Ground Cable Ground bar Powering on the Switch Connect the power cable and the switch first, then connect the power cable to the power supply system of the equipment room. Connecting Power Cord Anti-Trip(Optional) In order to protect the power supply from accidental disconnection, its recommended to purchase a power cord anti-trip for installation. 1. Place the smooth side of the fixing strap towards the power outlet and insert it into the hole on the side of it.
~ 5 ~
~ 6 ~
2. After plugging the power cord into the power outlet, slide the protector over the remaining strap until it slides over the end of the power cord. Connect to SFP Port The installation process of the fiber module is as follows:
1. Grasp the fiber module from the side and insert it smoothly along the switch SFP port slot until the module is in close contact with the switch. 3. Wrap the strap of the protective cord around the power cord and lock it tightly. Fasten the straps until the power cord is securely fastened. PORT CONNECTING Connect to RJ45 Port 1. Connect one end of the network cable to the switch, and the other end to the peer device. RJ45 port Crystal head RJ45 port 2. After powered on, check the status of the port indicator. If on, it means that the link is connected normally; if off, it means the link is disconnected, please check the cable and the peer device whether is enabled. SFP port Fiber module 2. When connecting, pay attention to confirm the Rx and Tx ports of SFP fiber module. Insert one end of the fiber into the Rx and Tx ports correspondingly, and connect the other end to another device. 3. After powered on, check the status of the port indicator. If on, it means that the link is connected normally; if off, it means the link is disconnected, please check the cable and the peer device whether is enabled. Notes:
Please select the optical fiber cable according to the module type. The multi-mode module corresponds to the multi-mode optical fiber, and the single-mode module corresponds to the single-mode optical fiber. Please select the same wavelength optical fiber cable for connection. Please select an appropriate optical module according to the actual networking situation to meet different transmission distance requirements. The laser of the first-class laser products is harmful to eyes. Do not look directly at the optical fiber connector.
~ 7 ~
~ 8 ~
Connect to Console Port 1. Connect the RJ45 end of the console cable to the console port of switch. 2. Connect the other end of the console cable to the DB9 male connector or USB port to the PC. Install on the Wall 1. Use the matching screws (KM 3*6) to fix the two L-shaped rack-
mounting kits (rotated 90) on both sides of switch. 2. Stick the switch port up and horizontally on the selected wall, mark the position of the screw hole on the L-shaped rack-mounting kits with a marker. Then, drill a hole at the marked position with an impact drill, and drill the expansion screws(prepared by yourself) into the drilled hole in the wall. 3. Use a screwdriver to tighten the screws(prepared by yourself) that have passed through the L-shaped rack-mounting kits to tighten the expansion solenoids to ensure that the switch is firmly installed on the wall. INSTALLATION Install on the Desktop 1. Place the bottom of switch on a sufficiently large and stable table. 2. Peel off the rubber protective paper of the four footpads one by one, and stick them in the corresponding circular grooves at the four corners of the bottom of the case. 3. Flip the switch over and place it smoothly on the table Rubber footpads Back of the Switch Circular groove Install on a 19 Standard Rack Note: GWN7802/GWN7802P/GWN7803/GWN7803P support rack mounting. 1. Check the grounding and stability of the rack. 2. Install the two L-shaped rack-mounting in the accessories on both sides of switch, and fix them with the screws provided (KM 3*6).
~ 9 ~
~ 10 ~
3. Type the switchs default management IP address http://192.168.0.254 in the browser, and enter username and password to login(The default administrator username is admin and the default random password can be found at the sticker on the GWN7800 switch) Method 2: Login using the Web UI 1. Use the console cable to connect the console port of switch and the serial port of PC. 2. Open the terminal emulation program of PC (e.g. SecureCRT), enter the default username and password to login. (The default administrator username is admin and the default random password can be found at the sticker on the GWN7800 switch). Method 3: Login Remotely using SSH/Telnet 1. Turn on the Telnet of switch. 2. Enter cmd in PC/Start. 3. Enter telnet 192.168.0.254 in the cmd window. 4. Enter the default username and password to login(The default the default random administrator username password can be found at the sticker on the GWN7800 switch). Method 4: Configure using GWN.Cloud / GWN Manager Type https://www.gwn.cloud in the browser, and enter the account and password to login the cloud platform. If you dont have an account, please register first or ask the administrator to assign one for you. is admin and The GNU GPL license terms are incorporated into the device firmware and an be accessed via the Web user interface of the device at my_device_ip/gpl_license. It can also be accessed here: https://www.grandstream.com/legal/open-source-
software To obtain a CD with GPL source code information please submit a written request to: info@grandstream.com Refer to online documents and FAQ for more detailed information:
https://www.grandstream.com/our-products 3. Place the switch in a proper position in the rack and support it by the bracket. 4. Fix the L-shaped rack-mounting to the guide grooves at both ends of the rack with screws(prepared by yourself) to ensure that the switch is stably and horizontally installed on the rack. ACCESS & CONFIGURE Method 1: Login using Ethernet port 1. A PC uses a network cable to correctly connect any RJ45 port of switch. 2. Set the Ethernet (or local connection) IP address of the PC to 192.168.0.x (x is any value between 1-253), and the subnet mask to 255.255.255.0, so that it is in the same network segment with switch IP address.
~ 11 ~
~ 12 ~
U. S. FCC Part 15 Regulatory Information This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note:This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. CAN ICES-003 (A)/NMB-003(A) If trouble is experienced with this equipment, please contact (Agent in the US):
Company Name: Grandstream Networks, Inc. Address: 126 Brookline Ave, 3rd Floor Boston, MA 02215, USA Tel: 1-617-5669300 Fax: 1-617-2491987