Grandstream Networks, Inc. 126 Brookline Ave, 3rd Floor Boston, MA 02215. USA Tel : +1 (617) 566 - 9300 Fax: +1 (617) 249 - 1987 www.grandstream.com In all EU member states, operation of 5150
- 5350 MHz is restricted to indoor use only. For Warranty and RMA information, please visit www.grandstream.com GSC3510 SIP Two-Way Intercom Speaker Quick Installation Guide EN The GSC3510 is not pre-configured to support or make emergency calls to any type of hospital, law enforcement agency, medical care unit
(Emergency Service(s)) or any other kind of Emergency Service. You must make additional arrangements to access Emergency Services. It is your responsibility to purchase SIP-compliant Internet telephone service, properly configure the GSC3510 to use that service, and periodical-
ly test your configuration to confirm that it works as you expect. It is also your responsibility to pur-
chase traditional wireless or landline telephone services to access Emergency Services. GRANDSTREAM DOES NOT PROVIDE CON-
NECTIONS TO EMERGENCY SERVICES VIA THE GSC3510. NEITHER GRANDSTREAM NOR ITS OF-
FICES, EMPLOYEES OR AFFILIATES MAY BE HELD LI-
ABLE FOR ANY CLAIM, DAMAGE, OR LOSS, AND YOU HEREBY WAIVE ANY AND ALL SUCH CLAIMS OR CAUSES OF ACTION ARISING FROM OR RE-
LATING TO YOUR INABILITY TO USE THE GSC3510 TO CONTACT EMERGENCY SERVICES, AND YOUR FAILURE TO MAKE ADDITIONAL ARRANGEMENTS TO ACCESS EMERGENCY SERVICES IN ACCOR-
DANCE WITH THE IMMEDIATELY PRECEDING PARAGRAPH. OVERVIEW GSC3510 is a two-way, full-duplex SIP intercom speaker featuring one 100Mbps Ethernet port with PoE/PoE+, integrated dual-band 2.4G/5G Wi-Fi, integrated Bluetooth, 3 directional microphones with Multichannel Microphone Array De-
sign (MMAD), high fidelity 8W speaker and a multi-purpose input port support-
ing a wide range of peripherals. The state-of-art microphone array and Hi-Fi speaker deliver full-duplex and full-band audio with pickup distance up to 4.2 meters. The built-in whitelist and blacklist features enables easy filtering of un-
wanted calls from the Internet. Its modern industrial design and rich features make it ideal for classrooms, hospitals, apartments, dormitories and much more. PRECAUTIONS Do not attempt to open, disassemble, or modify the device. Do not expose this device to temperatures outside range of 0 C to 40 C in op-
eration and -10 C to 60 C in storage. Do not expose the GSC3510 to environments outside of the following humidity range: 10-90% RH (non-condensing). Do not power cycle your GSC3510 during system boot up or firmware upgrade. You may corrupt firmware images and cause the unit to malfunction. PACKAGE CONTENTS GSC3510 Metal Bracket Plastic Bracket 3x Screw (PA 3.5 x 20) 3x M3 NUT 3x Plastic Expansion Bolt
~1~
1x Quick Installation Guide 1x GPL Statement
~2~
3x Screw (PM 3 x 50) GSC3510 PORTS Port Reset NET/PoE 2-Pin port Description Factory reset button. Press for 10 seconds to reset factory default settings. Ethernet RJ45 port (10/100Mbps) supporting PoE/PoE+. 2-pin multi-purpose input port.(switch action) HARDWARE INSTALLATION GSC3510 can be mounted on the wall or ceiling. Please refer to the following steps for the appropriate installation. Wall Mount 1. Locate the equipment holder on the desired po-
sition with arrow up. Drill three holes on the wall referring to the positions of holes on the metal bracket. 2. Fix the metal bracket on the wall by expansion screws. 3. Align the position line on devices back cover with the positioning slot. 4. Rotate the device clockwise untill it is locked on the right postion. 1 2 Ceiling Mount 1. Put the ceiling mounting (metal bracket) in the ceilings center and mark the posi-
tion of the three screw holes. 2. Drill a round hole with a diameter of 18mm for Ethernet cable. The distance between its center and the highlighted hole on the plastic bracket should be 35mm. 3. Fix the plastic and metal brackets on the ceiling with flat-head screws and lock-
nuts.Then place an Ethernet cable pass through the 18mm-round hole. 4. Align the position line on devices back cover with the positioning slot. 5. Rotate the device clockwise untill it is locked on the right postion. 1, 2 Plastic bracket Metal bracket 3 Positionining slot 4 5 35mm M3 nut M3.0x50 screw Lock POWERING AND CONNECTING THE GSC3510 GSC3510 can be powered on using PoE/PoE+ switch or PoE injector using following steps:
- Step 1: Plug a RJ45 Ethernet cable into the network port of the GSC3510.
- Step 2: Plug the other end into the power over Ethernet (PoE) switch or PoE injector. 4 3
~3~
Lock Positionining slot Network Port RJ45 Ethernet Cable to Power over Eth-
ernet (PoE) Switch or PoE injector.
~4~
ACCESSING THE CONFIGURATION INTERFACE A computer connected to the same network as the GSC3510 can discover and access its configuration interface using its MAC address :
1. Locate the MAC address on the MAC tag of the unit, which is on the underside of the device, or on the package. 2. From a computer connected to same network as the GSC3510, type in the fol-
lowing address using the GSC3510s MAC address on your browser:
https://gsc_<mac>.local Example: if a GSC3510 has the MAC address 00:0B:82:11:22:33, this unit can be accessed by typing https://gsc_000b82112233.local on the browser. FCC Caution:
For more information, please download the GSC3510 User Manual from:
http://www.grandstream.com/support
~5~
~6~