all | frequencies |
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|
manual | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 2 |
|
User Manual | Users Manual | 1.51 MiB | August 22 2022 | |||
1 2 |
|
Internal photo | Internal Photos | 3.94 MiB | August 22 2022 | |||
1 2 |
|
External photo | External Photos | 1.30 MiB | August 22 2022 | |||
1 2 |
|
Label | ID Label/Location Info | 665.38 KiB | August 22 2022 | |||
1 2 |
|
Applicant Declaration Letter | Cover Letter(s) | 218.22 KiB | August 22 2022 | |||
1 2 |
|
Auth letter | Cover Letter(s) | 115.18 KiB | August 22 2022 | |||
1 2 | Block diagram unit | Block Diagram | August 22 2022 | confidential | ||||
1 2 | Bolck diagram RF | Block Diagram | August 22 2022 | confidential | ||||
1 2 |
|
Confidentiality FCC | Cover Letter(s) | 140.58 KiB | August 22 2022 | |||
1 2 |
|
MCL | Cover Letter(s) | 128.36 KiB | August 22 2022 | |||
1 2 |
|
MPE | RF Exposure Info | 882.53 KiB | August 22 2022 | |||
1 2 | Operational description | Operational Description | August 22 2022 | confidential | ||||
1 2 | Schematics RF | Schematics | August 22 2022 | confidential | ||||
1 2 | Schematics Unit | Schematics | August 22 2022 | confidential | ||||
1 2 |
|
Setup photo | Test Setup Photos | 1.05 MiB | August 22 2022 | |||
1 2 |
|
Test report | Test Report | 5.26 MiB | August 22 2022 |
1 2 | User Manual | Users Manual | 1.51 MiB | August 22 2022 |
Video Intercom Villa Door Station User Manual Video Intercom Villa Door Station User Manual Legal Information 2020 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved. About this Manual The Manual includes instructions for using and managing the Product. Pictures, charts, images and all other information hereinafter are for description and explanation only. The information contained in the Manual is subject to change, without notice, due to firmware updates or other reasons. Please find the latest version of this Manual at the Hikvision website ( https://www.hikvision.com/ ). Please use this Manual with the guidance and assistance of professionals trained in supporting the Product. Trademarks and other Hikvision's trademarks and logos are the properties of Hikvision in various jurisdictions. Other trademarks and logos mentioned are the properties of their respective owners. Disclaimer TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED AS IS AND WITH ALL FAULTS AND ERRORS. HIKVISION MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF SYSTEMS, OR LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN i Video Intercom Villa Door Station User Manual CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS. YOU ACKNOWLEDGE THAT THE NATURE OF INTERNET PROVIDES FOR INHERENT SECURITY RISKS, AND HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER-ATTACK, HACKER ATTACK, VIRUS INSPECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED. YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW. ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS PRODUCT IN A MANNER THAT DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION, RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA PROTECTION AND OTHER PRIVACY RIGHTS. YOU SHALL NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES. IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATER PREVAILS. ii Video Intercom Villa Door Station User Manual Symbol Conventions The symbols that may be found in this document are defined as follows. Symbol Description Danger Caution Note Indicates a hazardous situation which, if not avoided, will or could result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, could result in equipment damage, data loss, performance degradation, or unexpected results. Provides additional information to emphasize or supplement important points of the main text. iii Video Intercom Villa Door Station User Manual Safety Instruction Warning The working temperature of the device is from -10 C to 55 C. All the electronic operation should be strictly compliance with the electrical safety regulations, fire prevention regulations and other related regulations in your local region. Please use the power adapter, which is provided by normal company. The power consumption cannot be less than the required value. Do not connect several devices to one power adapter as adapter overload may cause over-heat or fire hazard. Please make sure that the power has been disconnected before you wire, install or dismantle the device. When the product is installed on wall or ceiling, the device shall be firmly fixed. If smoke, odors or noise rise from the device, turn off the power at once and unplug the power cable, and then please contact the service center. If the product does not work properly, please contact your dealer or the nearest service center. Never attempt to disassemble the device yourself. (We shall not assume any responsibility for problems caused by unauthorized repair or maintenance.) Caution Do not drop the device or subject it to physical shock, and do not expose it to high electromagnetism radiation. Avoid the equipment installation on vibrations surface or places subject to shock (ignorance can cause equipment damage). Do not place the device in extremely hot (refer to the specification of the device for the detailed operating temperature), cold, dusty or damp locations, and do not expose it to high electromagnetic radiation. The device cover for indoor use shall be kept from rain and moisture. Exposing the equipment to direct sun light, low ventilation or heat source such as heater or radiator is forbidden (ignorance can cause fire danger). Do not aim the device at the sun or extra bright places. A blooming or smear may occur otherwise (which is not a malfunction however), and affecting the endurance of sensor at the same time. iv Video Intercom Villa Door Station User Manual Please use the provided glove when open up the device cover, avoid direct contact with the device cover, because the acidic sweat of the fingers may erode the surface coating of the device cover. Please use a soft and dry cloth when clean inside and outside surfaces of the device cover, do not use alkaline detergents. Please keep all wrappers after unpack them for future use. In case of any failure occurred, you need to return the device to the factory with the original wrapper. Transportation without the original wrapper may result in damage on the device and lead to additional costs. Improper use or replacement of the battery may result in hazard of explosion. Replace with the same or equivalent type only. Dispose of used batteries according to the instructions provided by the battery manufacturer. Input voltage should meet both the SELV and the Limited Power Source according to 60950-1 standard. The power supply must conform to LPS. The recommended adaptor models and manufacturers are shown as below. Use the attached adapter, and do not change the adaptor randomly. Model Manufacturer Standard ADS-24S-12 1224GPCN G0549-240-050 TS-A018-120015Ec SHENZHEN HONOR ELECTRONIC CO.,LTD SHENZHEN GOSPELL DIGITAL TECHNOLOGY CO.,LTD SHENZHEN TRANSIN TECHNOLOGIES CO., LTD CEE CEE CEE v Video Intercom Villa Door Station User Manual Regulatory Information FCC Information Please take attention that changes or modification not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help FCC Conditions This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body. vi Video Intercom Villa Door Station User Manual EU Conformity Statement This product and - if applicable - the supplied accessories too are marked with "CE" and comply therefore with the applicable harmonized European standards listed under the EMC Directive 2014/30/EU, the RoHS Directive 2011/65/EU 2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.info 2006/66/EC (battery directive): This product contains a battery that cannot be disposed of as unsorted municipal waste in the European Union. See the product documentation for specific battery information. The battery is marked with this symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return the battery to your supplier or to a designated collection point. For more information see:www.recyclethis.info Industry Canada ICES-003 Compliance This device meets the CAN ICES-3 (B)/NMB-3(B) standards requirements. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:
1. this device may not cause interference, and 2. this device must accept any interference, including interference that may cause undesired operation of the device. vii Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radioexempts de licence. L'exploitation est autorise aux deux conditions suivantes :
1. l'appareil ne doit pas produire de brouillage, et 2. l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Conformment la rglementation d'Industrie Canada, le prsent metteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou infrieur) approuv pour l'metteur par Industrie Canada. Dans le but de rduire les risques de brouillage radiolectrique l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonne quivalente (p.i.r.e.) ne dpasse pas l'intensit ncessaire l'tablissement d'une communication satisfaisante. This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body. Cet quipement doit tre install et utilis une distance minimale de 20 cm entre le radiateur et votre corps. viii Video Intercom Villa Door Station User Manual Contents 1 Appearance ................................................................................................ 1 2 Terminal and Wiring Description ................................................................ 7 2.1 Terminal Description ......................................................................................... 7 2.2 Wiring Description ............................................................................................ 8 2.2.1 Door Lock Wiring ...................................................................................... 8 2.2.2 Door Contact Wiring ................................................................................. 9 2.2.3 Exit Button Wiring .................................................................................... 9 2.2.4 Alarm Input Device Wiring ..................................................................... 10 3 Installation ................................................................................................ 11 3.1 Accessory Introduction ................................................................................... 11 3.2 Surface Mounting with Protective Shield ........................................................ 11 3.3 Surface Mounting without Protective Shield .................................................. 13 3.4 Flush Mounting with Protective Shield ........................................................... 15 3.5 Flush Mounting without Protective Shield ...................................................... 17 4 Activation ................................................................................................. 20 4.1 Activate Device via Web .................................................................................. 20 4.2 Activate Device via Client Software ................................................................. 20 4.3 Edit Network Parameters ................................................................................ 21 5 Remote Configuration via Web ................................................................ 22 5.1 Live View ......................................................................................................... 22 5.2 User Management .......................................................................................... 22 5.3 Number Settings ............................................................................................. 23 ix Video Intercom Villa Door Station User Manual 5.4 Device Management ....................................................................................... 23 5.5 Parameters Settings ........................................................................................ 23 5.5.1 Local Parameters Settings ....................................................................... 24 5.5.2 System Settings ....................................................................................... 25 5.5.3 Network Settings .................................................................................... 28 5.5.4 Video & Audio Settings ........................................................................... 31 5.5.5 Image Settings ........................................................................................ 34 5.5.6 Event Settings ......................................................................................... 37 5.5.7 Schedule Settings .................................................................................... 40 5.5.8 Intercom Settings .................................................................................... 40 5.5.9 Access Control Settings ........................................................................... 43 6 Configuration via Client Software ............................................................. 46 6.1 Device Management ....................................................................................... 46 6.1.1 Add Online Device .................................................................................. 46 6.1.2 Add Device by IP Address ....................................................................... 47 6.1.3 Add Device by IP Segment ...................................................................... 47 6.2 Live View via Door Station .............................................................................. 48 6.3 Organization Management ............................................................................. 48 6.3.1 Add Organization .................................................................................... 48 6.3.2 Modify and Delete Organization ............................................................. 49 6.4 Person Management ....................................................................................... 49 6.4.1 Add Person ............................................................................................. 49 6.4.2 Modify and Delete Person ...................................................................... 51 6.4.3 Change Person to Other Organization .................................................... 51 x Video Intercom Villa Door Station User Manual 6.4.4 Import and Export Person Information .................................................. 51 6.4.5 Get Person Information from Device ...................................................... 52 6.4.6 Issue Card in Batch ................................................................................. 52 6.4.7 Permission Settings ................................................................................. 54 6.5 Video Intercom Settings .................................................................................. 55 6.5.1 Receive Call from Door Station ............................................................... 55 6.5.2 Release Notice ........................................................................................ 56 6.5.3 Search Video Intercom Information ....................................................... 57 6.5.4 Upload Armed Information .................................................................... 58 A. Communication Matrix and Device Command ....................................... 60 xi Video Intercom Villa Door Station User Manual 1 Appearance Single-Button Villa Door Station Figure 1-1 Single-Button Villa Door Station Appearance Table 1-1 Description No. 1 2 Description Microphone Indicator 1 Video Intercom Villa Door Station User Manual Description Unlock (Green)/ Call (Orange)/
Communicate (White) Camera Loudspeaker Button Card Reading Area IR Light Micro SD Card Slot (Reserved) &
Debugging Port LAN Terminals No. 3 4 5 6 7 8 9 10 2 Video Intercom Villa Door Station User Manual Two-Button Villa Door Station No. 1 2 3 Figure 1-2 Two-Button Villa Door Station Appearance Table 1-2 Description Description Microphone Indicator Unlock (Green)/ Call (Orange)/
Communicate (White) Camera 3 Video Intercom Villa Door Station User Manual Description Loudspeaker Button Card Reading Area IR Light Micro SD Card Slot (Reserved) &
Debugging Port LAN Terminals No. 4 5 6 7 8 9 10 4 Video Intercom Villa Door Station User Manual Four-Button Villa Door Station No. 1 2 3 Figure 1-3 Four-Button Villa Door Station Appearance Table 1-3 Description Description Microphone Indicator Unlock (Green)/ Call (Orange)/
Communicate (White) Camera 5 Video Intercom Villa Door Station User Manual Description Loudspeaker Button Card Reading Area IR Light Micro SD Card Slot (Reserved) &
Debugging Port LAN Terminals No. 4 5 6 7 8 9 10 6 Video Intercom Villa Door Station User Manual 2 Terminal and Wiring Description 2.1 Terminal Description Name DOOR ALARM IN Figure 2-1 Terminal Description Table 2-1 Description of Terminal and Interfaces Interface Description NC2 COM2 NO2 GND NC1 COM1 NO1 GND AI1 AI2 Door Lock Relay Output 2 (NC) Common Interface Door Lock Relay Output 2 (NO) Grounding Door Lock Relay Output 1 (NO) Common Interface Door Lock Relay Output 1 (NO) Grounding Alarm Input 1 (For the access of Door Contact) Alarm Input 2 (For the access of Door Contact) Note Before accessing to the Door Contact, select Input as Door Status in I/O Settings page first. 7 Video Intercom Villa Door Station User Manual Name Interface Description AI3 AI4 485+
485-
RS-485 Alarm Input 3 (For the access of Exit Button) Alarm Input 4 (For the access of Exit Button) Note Before accessing to the Exit Button, select Input as Exit Button in I/O Settings page first. RS-485 Communication Interface Power Input 12 VDC 12 VDC Input Network GND LAN Network Interface 2.2 Wiring Description 2.2.1 Door Lock Wiring Figure 2-2 Door Lock Wiring 8 Video Intercom Villa Door Station User Manual Note Terminal NC1/COM1 is set as default for accessing magnetic lock/electric bolt;
terminal NO1/COM1 is set as default for accessing electric strike. To connect electric lock in terminal NO2/COM2/NC2, it is required to set the output of terminal NO2/COM2/NC2 to be electric lock with iVMS-4200 client software. 2.2.2 Door Contact Wiring Figure 2-3 Door Contact Wiring 2.2.3 Exit Button Wiring 9 Video Intercom Villa Door Station User Manual Figure 2-4 Exit Button Wiring 2.2.4 Alarm Input Device Wiring Figure 2-5 Alarm Input Device Wiring 10 Video Intercom Villa Door Station User Manual 3 Installation Note Make sure the device in the package is in good condition and all the assembly parts are included. Make sure your power supply matches your door station. Make sure all the related equipment is power-off during the installation. Check the product specification for the installation environment. 3.1 Accessory Introduction Figure 3-1 Accessory Introduction Note The dimension of gang box for door station is: 174 (length) 83.66 (width) 18
(depth) mm. 3.2 Surface Mounting with Protective Shield 11 Video Intercom Villa Door Station User Manual Before You Start Tools that you need to prepare for installation: Drill (2.846) and gradienter. Purchase the protective shield before installation. Steps 1. Stick the mounting template on the wall. Drill screw holes according to the mounting template. Remove the template from the wall. 2. Align the protective shield with mounting template. Figure 3-2 Mounting Template 3. Secure the mounting plate on the wall with 4 supplied screws according to the screw holes. 4. Secure the device on the mounting plate with 4 supplied set screws. 5. Fix the cover onto the device with the screw. 12 Video Intercom Villa Door Station User Manual Figure 3-3 Surface Mounting with Protective Shield 3.3 Surface Mounting without Protective Shield Before You Start Tools that you need to prepare for installation: Drill (2.846) and gradienter. Steps 1. Stick the mounting template on the wall. Drill screw holes according to the mounting template. Remove the template from the wall. 13 Video Intercom Villa Door Station User Manual Figure 3-4 Mounting Template 2. Secure the mounting plate on the wall with 4 supplied screws according to the screw holes. 3. Secure the device on the mounting plate with 4 supplied set screws. 4. Fix the cover onto the device with the screw. 14 Video Intercom Villa Door Station User Manual Figure 3-5 Surface Mounting without Protective Shield 3.4 Flush Mounting with Protective Shield Before You Start Tools that you need to prepare for installation: Drill (2.846) and gradienter. Purchase the protective shield before installation. Steps 1. Stick the mounting template on the wall. Drill the hole according to the mounting template. Remove the template from the wall. 15 Video Intercom Villa Door Station User Manual Figure 3-6 Mounting Template Note The suggested size of hole is 175 mm 84 mm 19 mm. 2. Install the gang box into the hole with 4 screws. 3. Align the protective shield with the gang box. 4. Insert the device to the gang box. Secure the device with 4 supplied screws. 5. Fix the cover onto the device with the screw. 16 Video Intercom Villa Door Station User Manual Figure 3-7 Flush Mounting with Protective Shield 3.5 Flush Mounting without Protective Shield Before You Start Tools that you need to prepare for installation: Drill (2.846) and gradienter. Steps 1. Stick the mounting template on the wall. Drill the hole according to the mounting template. Remove the template from the wall. 17 Video Intercom Villa Door Station User Manual Figure 3-8 Mounting Template Note The suggested size of hole is 175 mm 84 mm 19 mm. 2. Secure the gang box into the hole with 4 screws. 3. Insert the device to the gang box. Secure the device with 4 supplied screws. 4. Fix the cover onto the device with the screw. 18 Video Intercom Villa Door Station User Manual Figure 3-9 Flush Mounting without Protective Shield 19 Video Intercom Villa Door Station User Manual 4 Activation 4.1 Activate Device via Web You are required to activate the device first by setting a strong password for it before you can use the device. Default parameters of the door station are as follows:
Default IP Address: 192.0.0.65. Default Port No.: 8000. Default User Name: admin Steps 1. Power on the device, and connect the device to the network. 2. Enter the IP address into the address bar of the web browser, and click Enter to enter the activation page. Note The computer and the device should belong to the same subnet. 3. Create and enter a password into the password field. 4. Confirm the password. 5. Click OK to activate the device. 4.2 Activate Device via Client Software You can only configure and operate the door station after creating a password for the device activation. Default parameters of door station are as follows:
Default IP Address: 192.0.0.65. Default Port No.: 8000. Default User Name: admin. Steps 1. Run the client software, click Maintenance and Management Device Management Device to enter the page. 2. Click Online Device. 20 Video Intercom Villa Door Station User Manual 3. Select an inactivated device and click Activate. 4. Create a password, and confirm the password. Note We highly recommend you to create a strong password of your own choosing
(using a minimum of 8 characters, including at least three kinds of following categories: upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product. And we recommend you change your password regularly, especially in the high security system, changing the password monthly or weekly can better protect your product. 5. Click OK to activate the device. Note When the device is not activated, the basic operation and remote operation of device cannot be performed. You can hold the Ctrl or Shift key to select multiple devices in the online devices, and click the Activate button to activate devices in batch. 4.3 Edit Network Parameters To operate and configure the device via LAN (Local Area Network), you need connect the device in the same subnet with your PC. You can edit network parameters via iVMS-4200 client software. Steps 1. Select an online activated device and click the Modify Netinfo. 2. Edit the device IP address and gateway address to the same subnet with your computer. 3. Enter the password and click OK to save the network parameters modification. Note The default port No. is 8000. The default IP address of the door station is 192.0.0.65. After editing the network parameters of device, you should add the devices to the device list again. 21 Video Intercom Villa Door Station User Manual 5 Remote Configuration via Web 5.1 Live View In the browser address bar, enter the IP address of the device, and press the Enter key to enter the login page. Enter the user name and password and click Login to enter the Live View page. Or you can click Live View to enter the page. Figure 5-1 Live View You can start/stop live view, capture, record, audio on/off, two-way audio, etc. The stream type can be set as main stream or sub stream. For IE (Internet Explorer) or Google users, the device support two-way audio communication. Note Live View function may vary with different models. Please refer to the actual product. 5.2 User Management You can add, delete or search the information of the user. Click User to enter the settings page. Click Add and enter the Name, Floor No. and Room No. to add. Click Edit to modify the information of the user. 22 Video Intercom Villa Door Station User Manual Check the box of the user and click Delete to delete the selected user. Enter the keyword and click search icon. The information will display in the list. Note User management function may vary with different models. Please refer to the actual product. 5.3 Number Settings Link the room No. and SIP numbers. Click Number Settings to enter the page. Click Add, set the Room No. and SIP numbers in the pop-up dialog box. 5.4 Device Management You can manage the linked device on the page. Click Device List to enter the settings page. Add Device Click Add to add the indoor station or sub door station. Enter the parameters and click OK to add. Click Import. Enter the information of the device in the template to import devices in batch. Export Click Export to export the information to the PC. Synchronize Click Synchronize to synchronize the information. 5.5 Parameters Settings Click Configuration to set the parameters of the device. 23 Video Intercom Villa Door Station User Manual Remote configuration in iVMS-4200 and Batch Configuration Tool is the same as that in Web. Here takes the configuration in web for example. Note Run the browser, click Mode. Internet Options Security to disable the Protected 5.5.1 Local Parameters Settings You can configure the parameters of the live view, record files and captured pictures. The record files and captured pictures are the ones you record and capture by using the web browser. You can also set and view the saving paths of the captured pictures and recorded videos on the PC that running the web browser. Live View Parameters Stream Type Set the stream type as Main Stream or Sub-stream. Play Performance Set the live view performance to Shortest Delay, Balanced or Fluent. Auto Start Live View Check Yes to enable the function. Image Format Select the image format for picture capture. Click Save to enable the settings. Record File Parameters Record File Size Select the packed size of the manually recorded and downloaded video files to 256M, 512M or 1G. After the selection, the maximum record file size is the value you selected. Save record files to Set the saving path for the manually recorded video files. Click Save to enable the settings. 24 Video Intercom Villa Door Station User Manual Picture and Clip Settings Save snapshots in live view to Set the saving path of the manually captured pictures in live view mode. Note You can click Browse to change the directory for saving the clips and pictures, and click Open to open the set folder of clips and picture saving. Click Save to enable the settings. 5.5.2 System Settings Follow the instructions below to configure the system settings, include System Settings, Maintenance, Security, and User Management, etc. Click System to enter the settings page. Basic Information Click System Settings Basic Information to enter the settings page. On the page, you can edit Device Name and Device No. Set the Language and System Type according to your needs. Click Save to enable the settings. Time Settings Click System Settings Time Settings to enter the settings page. Select the Time Zone of your location from the drop-down list. Enable NTP, set the Server Address, NTP Port and Interval. Enable Manual Time Sync., set the time manually or check the Sync. with computer time. Click Save to enable the settings. DST Click System Settings DST to check Enable DST. Set the parameters according to your needs and click Save to enable the settings. 25 Video Intercom Villa Door Station User Manual Maintenance Click Maintenance Upgrade & Maintenance to enter the settings page. Reboot: Click Reboot to reboot the device. Figure 5-2 Maintenance Restore Click Restore to reset all the parameters, except the IP parameters and user information, to the default settings. Default Click Default to restore all parameters to default settings. Export parameters:
1. Select Device Parameters, and click Export to pop up the dialog box. 2. Set and confirm the encryption password. 3. Click OK to export parameters. Import Config. File:
1. Click browse icon to select the configuration file. 2. Click Import and enter the encryption password to import. Upgrade: Click browse icon to select the upgrade file. Note The upgrading process will last 1 to 10 minutes, do not power off during the upgrading. The device reboots automatically after upgrading. 26 Video Intercom Villa Door Station User Manual Authentication Click Security Authentication to enter the settings page. On the page, you can select RTSP Authenticationaccording to your actual needs. Click Save to enable the settings. Security Service Click Security Security Service to enter the settings page. On the page, you can enable SSH according to your actual needs. Click Save to enable the settings. User Management Click User Management to enter the settings page. Administrator can edit the permission for the users. Note We highly recommend you to create a strong password of your own choosing (using a minimum of 8 characters, including at least three kinds of following categories: upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product. And we recommend you change your password regularly, especially in the high security system, changing the password monthly or weekly can better protect your product. Online Users Click User Management Online Users to enter the page. Click Refresh to get the present information. Figure 5-3 Online Users 27 Video Intercom Villa Door Station User Manual Arming/Disarming Information Click User Management Arming/Disarming Information to view the information. Click Refresh to get the present information. 5.5.3 Network Settings TCP/IP Settings TCP/IP settings must be properly configured before you operate the device over network. The device supports IPv4. Steps 1. Click Network Basic Settings TCP/IP to enter the settings page. Figure 5-4 TCP/IP Settings 2. Configure the network parameters.
Check DHCP, the device will get the parameters automatically. Set the IPv4 Address, IPv4 Subnet Mask and IPv4 Default Gateway manually. 3. Configure the DNS server. 4. Click Save to enable the settings. Port Settings 28 Video Intercom Villa Door Station User Manual Steps 1. Click Network Basic Settings Port to enter the settings page. Figure 5-5 Port Settings 2. Set the ports of the device. HTTP Port The default port number is 80, and it can be changed to any port No. which is not occupied. RTSP Port The default port number is 554 and it can be changed to any port No. ranges from 1 to 65535. Server Port The default server port number is 8000, and it can be changed to any port No. ranges from 2000 to 65535. 3. Click Save to enable the settings. Wi-Fi Settings Steps 1. Click Network Basic Settings Wi-Fi Settings to enter the settings page. 2. Enter the SSID and Password of the Wi-Fi. 3. Select Security Mode. 4. Click Connect. SIP Setting Steps 1. Click Network Basic Settings SIP to enter the settings page. 2. Check Enable VOIP Gateway. 3. Configure the SIP parameters. 29 Video Intercom Villa Door Station User Manual 4. Click Save to enable the settings. FTP Settings Steps 1. Click Network Advanced Settings FTP to enter the settings page. Figure 5-6 FTP Settings 2. Check Enable FTP. 3. Select Server Type. 4. Input the Server IP Address and Port. 30 Video Intercom Villa Door Station User Manual 5. Configure the FTP Settings, and the user name and password are required for the server login. 6. Set the Directory Structure, Parent Directory and Child Directory. 7. Set the picture naming rules. 8. Click Save to enable the settings. Platform Access Platform access provides you an option to manage the devices via platform. Steps 1. Click Network Advanced Settings Platform Access to enter the settings page. 2. Check the checkbox of Enable to enable the function. 3. Select the Platform Access Mode. Note Hik-Connect is an application for mobile devices. With the App, you can view live image of the device, receive alarm notification and so on. 4. Create a Stream Encryption/Encryption for the device. Note 6 to 12 letters (a to z, A to Z) or numbers (0 to 9), case sensitive. You are recommended to use a combination of no less than 8 letters or numbers. 5. Click Save to enable the settings. 5.5.4 Video & Audio Settings Video Parameters Steps 1. Click Video/Audio Video to enter the settings page. 31 Video Intercom Villa Door Station User Manual Figure 5-7 Video Parameters 2. Select the Stream Type. 3. Configure the video parameters. Stream Type Select the stream type to main stream or sub stream. Video Type Select the stream type to video stream, or video & audio composite stream. The audio signal will be recorded only when the Video Type is Video &
Audio. Resolution Select the resolution of the video output. Bitrate Type Select the bitrate type to constant or variable. Video Quality When bitrate type is selected as Variable, 6 levels of video quality are selectable. Frame Rate Set the frame rate. The frame rate is to describe the frequency at which the video stream is updated and it is measured by frames per second (fps). A higher frame rate is advantageous when there is movement in the video stream, as it maintains image quality throughout. 32 Video Intercom Villa Door Station User Manual Max. Bitrate Set the max. bitrate from 32 to 16384 Kbps. The higher value corresponds to the higher video quality, but the better bandwidth is required. Video Encoding The device supports H.264. I Frame Interval Set I Frame Interval from 1 to 400. 4. Click Save to save the settings. Audio Parameters Steps 1. Click Video/Audio Audio to enter the settings page. Figure 5-8 Audio Settings 2. Configure the stream type and the audio encoding type. Stream Type Select the stream type to main stream or sub stream. Audio Encoding The device support G.711ulaw and G.711 alaw. 3. Adjust the Input Volume, Output Volume and Speak Volume. Note Available range of volume: 0 to 10. 4. Click Save to save the settings. 33 Video Intercom Villa Door Station User Manual 5.5.5 Image Settings Display Settings Configure the image adjustment, backlight settings and other parameters in display settings. Steps 1. Click Image Display Settings to enter the display settings page. Figure 5-9 Display Settings 2. Select the Format. 3. Set the display parameters. WDR Wide Dynamic Range can be used when there is a high contrast of the bright area and the dark area of the scene. Brightness Brightness describes bright of the image, which ranges from 1 to 100. Contrast Contrast describes the contrast of the image, which ranges from 1 to 100. Saturation Saturation describes the colorfulness of the image color, which ranges from 1 to 100. Sharpness Sharpness describes the edge contrast of the image, which ranges from 1 to 100. 34 Video Intercom Villa Door Station User Manual 4. Set the Day/Night Mode. Figure 5-10 Day/Night Mode
Set Day Mode or Night Mode manually. Set the mode as Auto and edit the sensitivity according to your needs. Set the mode as Scheduled-Switch. Set the start time and end time. Note Daytime is from configured start time to configured time. The rest of the time is set as night by default. 5. Set the backlight parameters. 35 Video Intercom Villa Door Station User Manual Figure 5-11 Backlight 1) Check the checkbox to enable BLC. 2) Select BLC Area. 6. Click Save to enable the settings. OSD Settings You can customize the camera name, time/date format, display mode, and OSD size displayed on the live view. Steps 1. Click Image OSD Settings to enter the settings page. 2. Check the corresponding checkbox to select the display of camera name, date or week if required. 3. Edit the Camera Name. 4. Select from the drop-down list to set the Time Format and Date Format. 5. Adjust the OSD position. 6. Click Save to enable the settings. Target Cropping 36 Video Intercom Villa Door Station User Manual Steps 1. Click Image. 2. Enable target cropping. 3. Click "
" to crop photo. 4. Click "
" to crop video. 5. Select Cropping Resolution. 6. Click Save. 5.5.6 Event Settings Motion Detection Motion detection detects the moving objects in the configured surveillance area, and a series of actions can be taken when the alarm is triggered. Steps 1. Click Event Motion to enter the settings page. 37 Video Intercom Villa Door Station User Manual 2. Check Enable Motion Detection to enable the function. Figure 5-12 Motion Detection 3. Click Draw Area. Click and drag the mouse on the live video to draw a motion detection area. Click Stop Drawing to finish drawing one area. Click Save to save the settings. Clear Area Click Clear All to clear all of the areas. Adjust Sensitivity Move the slider to set the sensitivity of the detection. 4. Click Arming Schedule to edit the arming schedule. 5. Click on the time bar and drag the mouse to select the time period. Click Save to save the settings. Delete Schedule Click Delete to delete the current arming schedule. 6. Click Linkage Method to enable the linkages. Notify Surveillance Center 38 Video Intercom Villa Door Station User Manual Send an exception or alarm signal to the remote management software when an event occurs. 7. Click Save to enable the settings. Event Linkage Steps 1. Click Event Basic Event Event Linkage to enter the settings page. 2. Select the Major Type as Device Event or Door Event. Figure 5-13 Event Linkage 39 Video Intercom Villa Door Station User Manual 3. Select the type of the Normal Linkage for the event. 4. Click Save to enable the settings. 5.5.7 Schedule Settings You can create call schedule, or else the device will call indoor station all day by default. Steps 1. Click Schedule Video Intercom . 2. Click the next row below Enable Indoor Station All Day by Default. 3. Enter Schedule Name. 4. Select Call Type. 5. Set Weekly Schedule. 1) Click Weekly Schedule. 2) Drag mouse to set the schedule according to the actual needs. 3) Optional: Click the copy icon to copy the schedule to other days according to the actual needs. 4) Click Save. 6. Set Holiday Schedule. 1) Click Holiday Schedule. 2) Click Add. 3) Set Start Time and End Time. 4) Select Call Type. 5) Drag mouse to set the schedule according to the actual needs. 6) Click OK. 7) You can edit or delete the schedule according to the actual needs. 8) Click Save. Note The holiday schedule have higher priority than weekly schedule when you set the two schedule at the same time. 5.5.8 Intercom Settings 40 Video Intercom Villa Door Station User Manual Device ID Configuration Steps 1. Click Device ID Settings to enter the page. Figure 5-14 Device ID Settings 2. Select the device type from the drop-down list, and set the corresponding information. 3. Click Save to enable the device number configuration. Note For main door station (D series or V series), the serial No. is 0. For sub door station (D series or V series), the serial No. cannot be 0. Serial No. ranges from 1 to 99. For each villa or building, at least one main door station (D series or V series) should be configured, and one sub door stations (D series or V series) can be customized. For one main door station (D series or V series), up to 8 sub door stations can be configured. Linked Network Settings Steps 1. Go to Intercom Session Settings to enter the settings page. 2. Set Register Number and Registration Password. 3. Set Main Station IP and VideoIntercom Server IP. 41 Video Intercom Villa Door Station User Manual 4. Enable Protocol 1.0. 5. Click Save to enable the settings. Time Parameters Go to Intercom Time Parameters to enter the page. Configure Max. Call Duration, Max. Message Duration, Max. Ring Duration, and click Save. Ring-Back Tone Settings Click Intercom Ringbacktone Settings to enter the settings page. Click Add to select the ring tone from PC. Note Available Audio Format: WAVAAC, Size: Less than 600 KB, Sample Rate: 8000Hz, Mono. Press Button to Call Steps 1. Go to Intercom Press Button to Call to enter the settings page. 2. Check Call Indoor Station or Call Management Center as the button call target. Note If you check Call Indoor Station, you should enter the call indoor station No. 3. Click Save. Input and Output Go to Intercom I/O Settings to enter the settings page. 42 Video Intercom Villa Door Station User Manual Figure 5-15 IO Input and Output Select I/O Input No., Input, I/O Output No. and Output. Click Save to enable the settings. 5.5.9 Access Control Settings Door Parameters Steps 1. Click Access Control Door Parameters to enter the settings page. Figure 5-16 Door Parameters 2. Select the door and edit the door name. 3. Set door contact status. 4. Set lock action time. 5. Click Save to enable the settings. Card Security 43 Video Intercom Villa Door Station User Manual Go to Access Control Card Security to enter the settings page. Slide to enable card encryption parameters and CPU card reading content. Click Save to enable the settings. Elevator Control Before You Start Make sure your door station is in the mode of main door station. Only the main door station support elevator control function. Make sure your door station has been connected to the elevator controller via RS-485 wire if you want to use RS-485 interface. Steps 1. Click Access Control Elevator Control to enter the corresponding configuration page. 2. Check to enable elevator control function. Figure 5-17 Elevator Control 3. Select an Elevator No., and select an elevator controller type for the elevator. 44 Video Intercom Villa Door Station User Manual 4. Set the Negative Floor. 5. Select the Interface Type as RS-485 or Network Interface. And enable the elevator control.
If you select RS-485, make sure you have connected the door station to the elevator controller with RS-485 wire. If you select Network interface, enter the elevator controller's IP address, port No., user name, and password.
6. Click Save to enable the settings. Note Up to 4 elevator controllers can be connected to one door station. Up to 10 negative floors can be added. Make sure the interface types of elevator controllers, which are connected to the same door station are consistent. 45 Video Intercom Villa Door Station User Manual 6 Configuration via Client Software 6.1 Device Management Device management includes device activation, adding device, editing device, and deleting device, and so on. After running the iVMS-4200, video intercom devices should be added to the client software for remote configuration and management. 6.1.1 Add Online Device Before You Start Make sure the device to be added is in the same subnet with your computer. Otherwise, please edit network parameters first. Steps 1. Click Online Device to select an active online device. 2. Click Add. 3. Enter corresponding information, and click Add. 46 Video Intercom Villa Door Station User Manual Figure 6-1 Add to the Client 6.1.2 Add Device by IP Address Steps 1. Click +Add to pop up the adding devices dialog box. 2. Select IP/Domain as Adding Mode. 3. Enter corresponding information. 4. Click Add. 6.1.3 Add Device by IP Segment 47 Video Intercom Villa Door Station User Manual You can add many devices at once whose IP addresses are among the IP segment. Steps 1. Click +Add to pop up the dialog box. 2. Select IP Segment as Adding Mode. 3. Enter corresponding information, and click Add. 6.2 Live View via Door Station Steps 1. On the main page of the client software, click Main View to enter the Live View page. 2. In the left list of the window, double-click the device IP or click the play icon to live view. 3. Optional: On the Live View page, control-click and select Capture to get the picture of the live view. 6.3 Organization Management On the main page of the Client Software, click the configuration page. PersonalManagement to enter 6.3.1 Add Organization Steps 1. In the organization list on the left, click +Add. 2. Enter the Organization Name as desired. 3. Click OK to save the adding. 4. Optional: You can add multiple levels of organizations according to the actual needs. 1) You can add multiple levels of organizations according to the actual needs. 2) Then the added organization will be the sub-organization of the upper-level organization. 48 Video Intercom Villa Door Station User Manual Note Up to 10 levels of organizations can be created. 6.3.2 Modify and Delete Organization You can select the added organization and click to modify its name. You can select an organization, and click X button to delete it. Note The lower-level organizations will be deleted as well if you delete an organization. Make sure there is no person added under the organization, or the organization cannot be deleted. 6.4 Person Management After adding the organization, you can add person to the organization and manage the added person such as issuing cards in batch, importing and exporting person's information in batch, etc. Note Up to 2,000 persons can be added. Up to 5 cards can be added to each person. 6.4.1 Add Person Person information is necessary for the video intercom system. And when you set linked device for the person, the intercom between intercom devices can be realized. Steps 1. Select an organization in the organization list and click Add on the Person panel to pop up the adding person dialog. Note The Person No. will be generated automatically and is editable. 2. Set basic person information. 49 Video Intercom Villa Door Station User Manual 1) Enter basic information: name, gender, tel, birthday details, effective period and email address. Note The length of person name should be less than 15 characters. 2) Click Add face to upload the photo. Note The picture should be in *.jpg format. Click Upload Select the person picture from the local PC to upload it to the client. Click Take Phone Take the person's photo with the PC camera. Click Remote Collection 3. Issue the card for the person. 1) Click Credential Card . Take the person's photo with the collection device. 2) Click + to pop up the Add Card dialog. 3) Select Normal Card as Card Type. 4) Enter the Card No. 5) Click Read and the card(s) will be issued to the person. 4. Link the device to the person. 1) Set the linked devices. Linked Device You can bind the indoor station to the person. Note If you select Analog Indoor Station in the Linked Device, the Door Station field will display and you are required to select the door station to communicate with the analog indoor station. Room No. You can enter the room No. of the person. 2) Click OK to save the settings. 5. Click Add to save the settings. 50 Video Intercom Villa Door Station User Manual 6.4.2 Modify and Delete Person Select the person and click Edit to open the editing person dialog. To delete the person, select a person and click Delete to delete it. Note If a card is issued to the current person, the linkage will be invalid after the person is deleted. 6.4.3 Change Person to Other Organization You can move the person to another organization if needed. Steps 1. Select the person in the list and click Change Organization. 2. Select the organization to move the person to. 3. Click OK to save the settings. 6.4.4 Import and Export Person Information The person information can be imported and exported in batch. Steps 1. Exporting Person: You can export the added persons' information in Excel format to the local PC. 1) After adding the person, you can click Export Person to pop up the following dialog. 2) Click ... to select the path of saving the exported Excel file. 3) Check the checkboxes to select the person information to export. 4) Click OK to start exporting. 2. Importing Person: You can import the Excel file with persons information in batch from the local PC. 1) Click Import Person. 2) You can click Download Template for Importing Person to download the template first. 3) Input the person information to the downloaded template. 4) Click ... to select the Excel file with person information. 51 Video Intercom Villa Door Station User Manual 5) Click OK to start importing. 6.4.5 Get Person Information from Device If the added device has been configured with person information (including person details, fingerprint, issued card information), you can get the person information from the device and import to the client for further operation. Steps Note This function is only supported by the device the connection mothod of which is TCP/IP when adding the device. 1. In the organization list on the left, click to select an organization to import the persons. 2. Click Get from Device to pop up the dialog box. 3. The added device will be displayed. 4. Click to select the device and then click Get to start getting the person information from the device. Note The person information, including person details, person's fingerprint information (if configured), and the linked card (if configured), will be imported to the selected organization. If the person name stored in the device is empty, the person name will be filled with the issued card No. after importing to the client. The gender of the persons will be Male by default. 6.4.6 Issue Card in Batch You can issue multiple cards for the person with no card issued in batch. Steps 1. Click Batch Issue Cards to enter the dialog page. All the added person with no card issued will display in the Person(s) with No Card Issued list. 52 Video Intercom Villa Door Station User Manual 2. Click Settings. Figure 6-2 Issue Card in Batch 53 Video Intercom Villa Door Station User Manual Figure 6-3 Card Settings 3. Select Card Type and Card No. Type. 4. Click OK to save the settings. Result After issuing the card to the person, the person and card information will display in the Person(s) with Card Issued list. 6.4.7 Permission Settings Add Permissions Steps 1. On the main page, click AccessControlInfo Access Group to enter the page. 2. Click +Add to pop up the adding dialog box. 3. Configure the parameters. 1) Enter the Name of the permission. 54 Video Intercom Villa Door Station User Manual 2) Select the Template of the schedule. 3) Check the person to Selected according to your needs. 4) Check the device to Selected according to your needs. 4. Click Save. 5. Check the permission and click Apply All to Device. The status of the permission displays as Applied. 6. Optional: Click Applying Status to check the details. Modify/Delete Permissions On the page of the permission settings, click permission. to edit the parameters of the Select one or more permissions, click Delete to remove the permissions. 6.5 Video Intercom Settings The Video Intercom Management module provides the function of video intercom, checking call logs and managing notice via the iVMS-4200 Client Software. Note For the user with access control module permissions, the user can enter the Access Control module and manage video intercom and search information. You should add the device to the software and configure the person to link the device in Access Control module before your configuration remotely. On the main page, click Intercom on the left bar to enter the Video Intercom page. AccessControlInfo Video Intercom Video 6.5.1 Receive Call from Door Station Steps 1. Select the client software in the page to start calling the client and an incoming call dialog will pop up in the client software. 2. Click Answer to answer the call. Or click Hang Up to decline the call. 3. After you answer the call, you will enter the In Call page. 55 Video Intercom Villa Door Station User Manual Adjust the Volume of Loudspeaker Click to adjust the volume of loudspeaker. Hang Up Click Hang Up to hang up. Adjust the Volume of Microphone Unlock Remotely Note Click to adjust the volume of microphone. For door station, you can click door remotely. to open the One video intercom device can only connect with one client software. The maximum ring duration can be set from 15s to 60s via the Remote Configuration of the video intercom device. The maximum speaking duration between indoor station and iVMS-4200 can be set from 120s to 600s via the Remote Configuration of indoor station. The maximum speaking duration between door station and iVMS-4200 can be set from 90s to 120s via the Remote Configuration of door station. 6.5.2 Release Notice You can create different types of notices and send them to the residents. Four notice types are available, including Advertising, Property, Alarm and Notice Information. Before You Start Make sure the person has been added to the client. Steps 1. On the video intercom settings page, click Notice to enter the page. 2. Click +Add to pop up the adding dialog box. 3. Select the person according to your needs. 4. Edit the Subject, Type and Information. 5. Click View to select the picture. 6. Click Send. 56 Video Intercom Villa Door Station User Manual Note Up to 63 characters are allowed in the Subject field. Up to 6 pictures in the JPGE format can be added to one notice. And the maximum size of one picture is 512KB. Up to 1023 characters are allowed in the Information field. 6.5.3 Search Video Intercom Information Search Call Logs Steps 1. On the Video Intercom page, click Call Log to enter the page. 2. Set the search conditions, including call status, device type, start time and end Figure 6-4 Search Call Logs time. Call Status Click to unfold the drop-down list and select the call status as Dialed, Received or Missed. Or select All to search logs with all statuses. Device Type Click to unfold the drop-down list and select the device type as Indoor Station, Door Station, Outer Door Station or Analog Indoor Station. Or select All Devices to search logs with all device types. 57 Video Intercom Villa Door Station User Manual Start Time/End Time Click the time icon to specify the start time and end time of a time period to search the logs. Reset the Settings Click Reset to reset all the configured search conditions. 3. Click Search and all the matched call logs will display on this page. 4. Optional: Check the detailed information of searched call logs, such as call status, ring/speaking duration, device name, resident organization, etc. 5. Optional: Input keywords in the Search field to filter the desired log. 6. Optional: Click Export to export the call logs to your PC. Search Notice Steps 1. On the Video Intercom page, click Notice to enter the page. 2. Set the search conditions, including notice type, start time and end time. Type Select Advertising Information, Property Information, Alarm Information or Notice Information as Type according to your needs. Start Time/End Time Click the time icon to specify the start time and end time of a time period to search the logs. Reset the Settings Click Reset to reset all the configured search conditiions. 3. Click Search and the matched notice will display on this page. 4. Optional: Click Export to export the notices to your PC. 6.5.4 Upload Armed Information Steps 1. On the main page, click upper right Tool DeviceGuard to enter the page. 2. Enable to arm or disarm the device. 58 Video Intercom Villa Door Station User Manual Note While device has been added to the client software, the device armed by default. When the device is armed, the alarm logs upload to the client software automatically. Click Alarm Application Event Search to search the alarm logs. 3. Optional: Click Arm All or Disarm All to arm or disarm all the device. 59 Video Intercom Villa Door Station User Manual A. Communication Matrix and Device Command Communication Matrix Scan the following QR code to get the device communication matrix. Note that the matrix contains all communication ports of Hikvision access control and video intercom devices. Figure A-1 QR Code of Communication Matrix Device Command Scan the following QR code to get the device common serial port commands. Note that the command list contains all commonly used serial ports commands for all Hikvision access control and video intercom devices. Figure A-2 Device Command 60 UD20207B
1 2 | Applicant Declaration Letter | Cover Letter(s) | 218.22 KiB | August 22 2022 |
SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia 30024 United States Applicant Declaration Applicant Legal Business Name Hangzhou Hikvision Digital Technology Co., Ltd. Address Grantee Code FCC ID No. 555 Qianmo Road, Binjiang District, Hangzhou 310052, China 2ADTD 2ADTD-KV8213WME1 Authorized Contact Name Long Cheng Contact Email Contact Phone chenglong6@hikvision.com
+8618969187825 I, the undersigned, certify that I am an authorized signatory for the Applicant and therefore declare;
a) b) c) d) e) in accordance with 47CFR2.911(d), all of the statements herein and the exhibits attached hereto are true and correct to the best of my knowledge and belief. in accepting a Grant of Equipment Authorization issued by a TCB, under the authority of the FCC, as a result of the representations made in this application, the Applicant is responsible for:
labeling the equipment with the exact FCC ID as specified in this application,
(1)
(2) compliance statement labeling pursuant to the applicable rules,
(3) compliance of the equipment with the applicable technical rules, if the Applicant is not the actual manufacturer of the equipment, appropriate arrangements have been made with the manufacturer to ensure that production units of this equipment will continue to comply with the FCCs technical requirements. in accordance with 47 CFR 2.909 and KDB394321, the Applicant has read, understood and agrees to accept that they are the responsible party and agree to abide by their responsibilities as specified under 47 CFR 2.909 and KDB394321. in accordance with ISO17065, FCC KDB641163, FCC KDB610077, KDB394321 and RSP-100, the Applicant has read, understood, accepts and agrees to abide by the post market surveillance requirements.
(1)
(2)
(3) the Applicant understands, accepts and agrees that a sample may be requested for surveillance testing. the Applicant shall make provisions to always have a production sample available upon request by SGS, FCC and/or ISED. the Applicant shall, upon request by SGS, at the Applicants expense, provide a production sample of the requested product to SGS, FCC and/or ISED as instructed. The sample shall include all support devices, cables, software, accessories or other hardware or software required for evaluation, review, certification and audit surveillance of products certified by SGS. f) neither the Applicant nor any party to the application is subject to a denial of Federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862 because of a conviction for possession or distribution of a controlled substance. See 47CFR 1.2002(b) for the definition of a party for these purposes. g) the Applicant has read, understood, accepts and agrees to abide by the SGS North America, Inc.(TCB) terms and conditions. Link to CFRs: https://www.fcc.gov/wireless/bureau-divisions/technologies-systems-and-innovation-division/rules-regulations-title-47 Link to KDBs: https://apps.fcc.gov/oetcf/kdb/index.cfm Link to RSP-100: https://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf01130.html Date: 2022-08-17 Applicant Signature:
Print Name:
Title:
*NOTE: This declaration cannot be signed by an Agent, it shall be signed by an authorized person listed in the FCC database Long Cheng Testing & Certification Engineer Applicant Declaration Rev:0.0
1 2 | Auth letter | Cover Letter(s) | 115.18 KiB | August 22 2022 |
Hangzhou Hikvision Digital Technology Co., Ltd. TO:
Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Regarding: FCC ID: 2ADTD-KV8213WME1 To whom it may concern:
Date: 2022-08-17 We, the undersigned, hereby authorize Parlam Zhan to act on our behalf in all manners relating to application for equipment authorization with respect to the FCC ID above, including signing of all documents relating to these matters. Any and all acts carried out by the agent on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Where our agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by SGS North America, Inc., still resides with Hangzhou Hikvision Digital Technology Co., Ltd. This authorization is valid until further written notice from the applicant. Name (Printed): Long Cheng Title: Testing & Certification Engineer Signature:
On behalf of Company: Hangzhou Hikvision Digital Technology Co., Ltd. Telephone: +8618969187825
1 2 | Confidentiality FCC | Cover Letter(s) | 140.58 KiB | August 22 2022 |
Hangzhou Hikvision Digital Technology Co., Ltd. To:
SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia United States From: Hangzhou Hikvision Digital Technology Co., Ltd. No. 555 Qianmo Road, Binjiang District, Hangzhou 310052, China Regarding:
Confidentiality Request regarding application for FCC ID: 2ADTD-KV8213WME1 LONG TERM CONFIDENTIALITY Pursuant to 47 CFR Section 0.459 and 0.457 of the commissions rules, the applicant hereby request confidential treatment of the documents listed below, associated with the certification application referenced above. Schematic(s) Block Diagrams Operational Descriptions The documents above contain proprietary information not released to the public. Public disclosure of this information may prove harmful to the business of the applicant. Sincerely, Signature:
Printed Name (on file with the FCC associated with the Grantee Code): Long Cheng Title: Testing & Certification Engineer Company Name: Hangzhou Hikvision Digital Technology Co., Ltd.
1 2 | MCL | Cover Letter(s) | 128.36 KiB | August 22 2022 |
Hangzhou Hikvision Digital Technology Co., Ltd. Current Date: 2022-08-17 To:
SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. No. 588 West Jindu Road, Songjiang District, Shanghai, China. 201612 Dear Sir/Madam, Subject: Declaration Letter about Identity of Products
*WE (Hangzhou Hikvision Digital Technology Co., Ltd.) HEREBY DECLARED THAT Product Description Door Station Model No. DS-KV8413-WME1(C)UHK,DS-KV8413-WME1(C)CKV, DS-KV8413-WME1(C)UVS,DS-KV8413-WME1(C)KVO, DS-KV8413-WME1(C)HUN,DS-KV8213-WME1(C), DS-KV8213-WME1(C)UHK,DS-KV8213-WME1(C)CKV, DS-KV8213-WME1(C)UVS,DS-KV8213-WME1(C)KVO, DS-KV8213-WME1(C)HUN,DS-KV8113-WME1(C), DS-KV8113-WME1(C)UHK,DS-KV8113-WME1(C)CKV, DS-KV8113-WME1(C)UVS,DS-KV8113-WME1(C)KVO, DS-KV8113-WME1(C)HUN Manufacturers Name Hangzhou Hikvision Digital Technology Co., Ltd. Manufacturers Address No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China
*Except that the model number and buttons deviation, are identical with the original product as follows:
Note: The definition of identical should be electrically identical. A device will be considered to be electrically identical if no changes are made to the devices schematics, board layouts, component layouts, chip sets, resistors and all other electrical aspects of the device are identical. Model No. ():
DS-KV8413-WME1(C) Manufacturers Name (): Hangzhou Hikvision Digital Technology Co., Ltd. Manufacturers Address ):
No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China Sincerely, Signature ():
Printed Name ():
Long Cheng Position/Title ():
Testing & Certification Engineer Contact Number ():
+8618969187825
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2022-08-22 | 2422 ~ 2452 | DTS - Digital Transmission System | Original Equipment |
2 | 13.56 ~ 13.56 | DXX - Part 15 Low Power Communication Device Transmitter |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 2 | Effective |
2022-08-22
|
||||
1 2 | Applicant's complete, legal business name |
Hangzhou Hikvision Digital Technology Co., Ltd.
|
||||
1 2 | FCC Registration Number (FRN) |
0024149825
|
||||
1 2 | Physical Address |
No. 555 Qianmo Road, Binjiang District
|
||||
1 2 |
Hangzhou, N/A
|
|||||
1 2 |
China
|
|||||
app s | TCB Information | |||||
1 2 | TCB Application Email Address |
U******@SGS.COM
|
||||
1 2 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
1 2 |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
|||||
app s | FCC ID | |||||
1 2 | Grantee Code |
2ADTD
|
||||
1 2 | Equipment Product Code |
KV8213WME1
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 2 | Name |
L**** C****
|
||||
1 2 | Telephone Number |
+8618********
|
||||
1 2 | Fax Number |
+86-5********
|
||||
1 2 |
c******@hikvision.com
|
|||||
app s | Technical Contact | |||||
1 2 | Firm Name |
SGS-CSTC Standards Technical Services Co., Ltd.
|
||||
1 2 | Name |
P****** Z********
|
||||
1 2 | Physical Address |
588 West Jindu Road, Xinqiao, Songjiang
|
||||
1 2 |
ShangHai, 201612
|
|||||
1 2 |
China
|
|||||
1 2 | Telephone Number |
+8621********
|
||||
1 2 | Fax Number |
02161********
|
||||
1 2 |
P******@sgs.com
|
|||||
app s | Non Technical Contact | |||||
1 2 | Firm Name |
SGS-CSTC Standards Technical Services Co., Ltd.
|
||||
1 2 | Name |
P**** Z******
|
||||
1 2 | Physical Address |
588 West Jindu Road, Xinqiao, Songjiang
|
||||
1 2 |
ShangHai, 201612
|
|||||
1 2 |
China
|
|||||
1 2 | Telephone Number |
+8621********
|
||||
1 2 | Fax Number |
02161********
|
||||
1 2 |
P******@sgs.com
|
|||||
app s | Confidentiality (long or short term) | |||||
1 2 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 2 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 2 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 2 | Equipment Class | DTS - Digital Transmission System | ||||
1 2 | DXX - Part 15 Low Power Communication Device Transmitter | |||||
1 2 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Door Station | ||||
1 2 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 2 | Modular Equipment Type | Does not apply | ||||
1 2 | Purpose / Application is for | Original Equipment | ||||
1 2 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | Yes | ||||
1 2 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 2 | Grant Comments | Power Output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter evaluation procedures as documented in this filing. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20 MHz and 40MHz bandwidth mode. | ||||
1 2 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 2 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 2 | Firm Name |
Compliance Certification Services (Kunshan) Inc.
|
||||
1 2 | Name |
J******** C******
|
||||
1 2 | Telephone Number |
+ 86-******** Extension:
|
||||
1 2 |
J******@sgs.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | CC | 2412 | 2462 | 0.03 | |||||||||||||||||||||||||||||||||||
1 | 2 | 15C | CC | 2422 | 2452 | 0.023 | |||||||||||||||||||||||||||||||||||
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
2 | 1 | 15C | CC | 13.56000000 | 13.56000000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC