all | frequencies |
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|
manual | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User Manual | Users Manual | 5.30 MiB | September 28 2021 | |||
1 |
|
Internal photo | Internal Photos | 2.61 MiB | September 28 2021 | |||
1 |
|
External photo | External Photos | 387.91 KiB | September 28 2021 | |||
1 |
|
Label | ID Label/Location Info | 203.16 KiB | September 28 2021 | |||
1 |
|
Applicant Declaration Letter | Cover Letter(s) | 117.71 KiB | September 28 2021 | |||
1 |
|
Auth letter | Cover Letter(s) | 27.36 KiB | September 28 2021 | |||
1 |
|
Confidentiality FCC | Cover Letter(s) | 87.40 KiB | September 28 2021 | |||
1 |
|
MCL | Cover Letter(s) | 145.66 KiB | September 28 2021 | |||
1 |
|
Test report | Test Report | 1.37 MiB | September 28 2021 | |||
1 |
|
Test setup photo | Test Setup Photos | 441.03 KiB | September 28 2021 |
1 | User Manual | Users Manual | 5.30 MiB | September 28 2021 |
DS-K3Y411X Series Flap Barrier Quick Start Guide DS-K3Y411X Series Flap Barrier Quick Start Guide Legal Information 2021 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved. About this Manual The Manual includes instructions for using and managing the Product. Pictures, charts, images and all other information hereinafter are for description and explanation only. The information contained in the Manual is subject to change, without notice, due to firmware updates or other reasons. Please find the latest version of this Manual at the Hikvision website ( https://
www.hikvision.com/ ). Please use this Manual with the guidance and assistance of professionals trained in supporting the Product. Trademarks Hikvision in various jurisdictions. Other trademarks and logos mentioned are the properties of their respective owners. and other Hikvision's trademarks and logos are the properties of Disclaimer TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED "AS IS" AND "WITH ALL FAULTS AND ERRORS". HIKVISION MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF SYSTEMS, OR LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS. YOU ACKNOWLEDGE THAT THE NATURE OF THE INTERNET PROVIDES FOR INHERENT SECURITY RISKS, AND HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER-ATTACK, HACKER ATTACK, VIRUS INFECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED. YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW. ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS PRODUCT IN A MANNER THAT DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION, RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA PROTECTION AND OTHER PRIVACY RIGHTS. YOU SHALL NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE i DS-K3Y411X Series Flap Barrier Quick Start Guide DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES. IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATTER PREVAILS. Data Protection During the use of device, personal data will be collected, stored and processed. To protect data, the development of Hikvision devices incorporates privacy by design principles. For example, for device with facial recognition features, biometrics data is stored in your device with encryption method; for fingerprint device, only fingerprint template will be saved, which is impossible to reconstruct a fingerprint image. As data controller, you are advised to collect, store, process and transfer data in accordance with the applicable data protection laws and regulations, including without limitation, conducting security controls to safeguard personal data, such as, implementing reasonable administrative and physical security controls, conduct periodic reviews and assessments of the effectiveness of your security controls. ii DS-K3Y411X Series Flap Barrier Quick Start Guide Regulatory Information FCC Information Please take attention that changes or modification not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help FCC Conditions This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. EU Conformity Statement This product and - if applicable - the supplied accessories too are marked with "CE"
and comply therefore with the applicable harmonized European standards listed iii DS-K3Y411X Series Flap Barrier Quick Start Guide under the EMC Directive 2014/30/EU, RE Directive 2014/53/EU,the RoHS Directive 2011/65/EU 2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see:
www.recyclethis.info 2006/66/EC (battery directive): This product contains a battery that cannot be disposed of as unsorted municipal waste in the European Union. See the product documentation for specific battery information. The battery is marked with this symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury
(Hg). For proper recycling, return the battery to your supplier or to a designated collection point. For more information see:www.recyclethis.info This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radioexempts de licence. L'exploitation est autorise aux deux conditions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. COMPLIANCE NOTICE The thermal series products might be subject to export controls in various countries or regions, including without limitation, the United States, European Union, United Kingdom and/or other member countries of the Wassenaar Arrangement. Please consult your professional legal or compliance expert or local government authorities for any necessary export license requirements if you intend to transfer, export, re-export the thermal series products between different countries. iv DS-K3Y411X Series Flap Barrier Quick Start Guide Safety Instruction These instructions are intended to ensure that user can use the product correctly to avoid danger or property loss. The precaution measure is divided into Dangers and Cautions:
Dangers: Neglecting any of the warnings may cause serious injury or death. Cautions: Neglecting any of the cautions may cause injury or equipment damage. Dangers: Follow these safeguards to prevent serious injury or death. Cautions: Follow these precautions to prevent potential injury or material damage. Danger:
In the use of the product, you must be in strict compliance with the electrical safety regulations of the nation and region. The equipment must be connected to an earthed mains socket-outlet. Shock hazard! Disconnect all power sources before maintenance. Do not touch the bare metal contacts of the inlets after the circuit breaker is turned off. Electricity still exists. indicates hazardous live and the external wiring connected to the terminals requires installation by an instructed person. Keep body parts away from fan blades. Disconnect the power source during servicing. Keep body parts away from motors. Disconnect the power source during servicing. To prevent possible hearing damage, do not listen at high volume levels for long periods. All the electronic operation should be strictly compliance with the electrical safety regulations, fire prevention regulations and other related regulations in your local region. Do not connect several devices to one power adapter as adapter overload may cause over-heat or fire hazard. Please make sure that the power has been disconnected before you wire, install or dismantle the device. If the top caps should be open and the device should be powered on for maintenance, make sure:
1. Power off the fan to prevent the operator from getting injured accidentally. 2. Do not touch bare high-voltage components. 3. Make sure the switchs wiring sequence is correct after maintenance. Please make sure that the power has been disconnected before you wire, install or dismantle the device. When the product is installed on wall or ceiling, the device shall be firmly fixed. If smoke, odors or noise rise from the device, turn off the power at once and unplug the power cable, and then please contact the service center. v DS-K3Y411X Series Flap Barrier Quick Start Guide Do not ingest battery, Chemical Burn Hazard. This product contains a coin/button cell battery. If the coin/button cell battery is swallowed, it can cause severe internal burns in just 2 hours and can lead to death. Keep new and used batteries away from children. If the battery compartment does not close securely, stop using the product and keep it away from children. If you think batteries might have been swallowed or placed inside any part of the body, seek immediate medical attention. If the product does not work properly, please contact your dealer or the nearest service center. Never attempt to disassemble the device yourself. (We shall not assume any responsibility for problems caused by unauthorized repair or maintenance.) Cautions:
The equipment shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases, shall be placed on the equipment. Ensure correct wiring of the terminals for connection to an AC mains supply. The equipment has been designed, when required, modified for connection to an IT power distribution system.
+ identifies the positive terminal(s) of equipment which is used with, or generates direct current.
+ identifies the negative terminal(s) of equipment which is used with, or generates direct current. No naked flame sources, such as lighted candles, should be placed on the equipment. This equipment is suitable for mounting on concrete or other non-combustible surface only. Install the equipment according to the instructions in this manual. To prevent injury, this equipment must be securely attached to the floor/wall in accordance with the installation instructions. Stainless steel may be corroded in some circumstances. You need to clean and care the device by using the stainless steel cleaner. It is suggested to clean the device every month. Do not drop the device or subject it to physical shock, and do not expose it to high electromagnetism radiation. Avoid the equipment installation on vibrations surface or places subject to shock (ignorance can cause equipment damage). Do not place the device in extremely hot (refer to the specification of the device for the detailed operating temperature), cold, dusty or damp locations, and do not expose it to high electromagnetic radiation. The device cover for indoor use shall be kept from rain and moisture. Exposing the equipment to direct sun light, low ventilation or heat source such as heater or radiator is forbidden (ignorance can cause fire danger). Do not aim the device at the sun or extra bright places. A blooming or smear may occur otherwise (which is not a malfunction however), and affecting the endurance of sensor at the same time. Please use the provided glove when open up the device cover, avoid direct contact with the device cover, because the acidic sweat of the fingers may erode the surface coating of the device cover. Please use a soft and dry cloth when clean inside and outside surfaces of the device cover, do not use alkaline detergents. vi DS-K3Y411X Series Flap Barrier Quick Start Guide Please keep all wrappers after unpack them for future use. In case of any failure occurred, you need to return the device to the factory with the original wrapper. Transportation without the original wrapper may result in damage on the device and lead to additional costs. Improper use or replacement of the battery may result in hazard of explosion. Replace with the same or equivalent type only. Dispose of used batteries according to the instructions provided by the battery manufacturer. Biometric recognition products are not 100% applicable to anti-spoofing environments. If you require a higher security level, use multiple authentication modes. Do not stay in the lane when the device is rebooting. RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS. SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY. The instructions shall require connection of the equipment protective earthing conductor to the installation protective earthing conductor. vii DS-K3Y411X Series Flap Barrier Quick Start Guide Available Models Product Name Model Description Example Flap Barrier DS-K3Y411X-L1 Left Pedestal 1 DS-K3Y411X-L2 Left Pedestal 2 DS-K3Y411X-M1 Middle Pedestal 1 DS-K3Y411X-M2 Middle Pedestal 2 DS-K3Y411X-R Right Pedestal You can follow the picture below to select pedestals:
DS-K3Y411X-L1/Dp60 DS-K3Y411X-L1/Dp60-
S12 DS-K3Y411X-L2/Dp60 DS-K3Y411X-L2/Dp60-
S12 DS-K3Y411X-M1/M-
Dp60 DS-K3Y411X-M1/M-
Dp60-S12 DS-K3Y411X-M2/M-
Dp60 DS-K3Y411X-M2/M-
Dp60-S12 DS-K3Y411X-R/M-Dp60 DS-K3Y411X-R/M-
Dp60-S12 viii DS-K3Y411X Series Flap Barrier Quick Start Guide Scan the QR code to get User Manual of Flap Barrier. Note that mobile data charges may apply if Wi-Fi is unavailable. ix DS-K3Y411X Series Flap Barrier Quick Start Guide Contents Chapter 1 Overview .................................................................................................................... 1 1.1 Introduction ........................................................................................................................... 1 1.2 Main Features ........................................................................................................................ 1 Chapter 2 System Wiring ............................................................................................................ 3 Chapter 3 Installation ................................................................................................................. 6 3.1 Disassemble Pedestals ........................................................................................................... 6 3.2 Install Pedestals ..................................................................................................................... 7 Chapter 4 General Wiring ......................................................................................................... 10 4.1 Components Introduction .................................................................................................... 10 4.2 Wiring Electric Supply .......................................................................................................... 12 4.3 Wire Interconnecting Cable ................................................................................................. 14 4.4 Face Recognition Terminal Power Supply Wiring (Optional) ................................................ 16 4.5 Terminal Description ............................................................................................................ 17 4.5.1 UART Related Terminal and Position ........................................................................... 17 4.5.2 Main Control Board Terminal Description ................................................................... 20 4.5.3 Sub Control Board Terminal Description ..................................................................... 21 4.5.4 BUS Terminal Description ............................................................................................ 22 4.5.5 Access Control Board Terminal Description ................................................................ 24 4.5.6 Access Control Board UART Description ..................................................................... 30 4.5.7 RS-485 Wiring ............................................................................................................. 36 4.5.8 RS-232 Wiring ............................................................................................................. 37 4.5.9 Barrier Control Wiring ................................................................................................. 38 4.5.10 Alarm Output Wiring ................................................................................................. 39 Chapter 5 Device Settings ......................................................................................................... 40 5.1 Pair Keyfob (Optional) .......................................................................................................... 40 5.2 Initialize Device .................................................................................................................... 41 x DS-K3Y411X Series Flap Barrier Quick Start Guide 5.3 Switch Relay Output Mode (NO/NC) .................................................................................... 43 5.3.1 Barrier Control Relay Output Mode ............................................................................ 43 5.3.2 Alarm Relay Output Mode (NO/NC) ............................................................................ 44 Chapter 6 Activation ................................................................................................................. 47 6.1 Activate via SADP ................................................................................................................. 47 6.2 Activate Device via Client Software ...................................................................................... 48 Appendix A. DIP Switch Description .......................................................................................... 50 Appendix B. Event and Alarm Type ........................................................................................... 51 Appendix C. Table of Audio Index Related Content ................................................................... 52 Appendix D. Error Code Description .......................................................................................... 53 Appendix E. Communication Matrix and Device Command ....................................................... 54 xi DS-K3Y411X Series Flap Barrier Quick Start Guide Chapter 1 Overview 1.1 Introduction The flap barrier with two barriers and 12 IR lights is designed to detect unauthorized entrance or exit. By adopting the flap barrier integratedly with the access control system, person should authenticate to pass through the lane via swiping IC or ID card, scanning QR code, etc. It is widely used in attractions, stadiums, construction sites, residences, etc. 1.2 Main Features 32-bit high-speed processor TCP/IP network communication and network speed adaptive The communication data is specially encrypted to relieve the concern of privacy leak Permissions validation and anti-tailgating Remaining open/closed mode selectable Bidirectional (Entering/Exiting) lane The barrier opening and closing speed can be configured according to the visitor flow The barrier will be locked or stop working when people are nipped Anti-forced-accessing The barrier will be locked automatically without open-barrier signal. Self-detection, Self-diagnostics, and automatic alarm Audible and visual alarm will be triggered when detecting intrusion, tailgating, reverse passing, and climbing over barrier IP conflict detection 1 DS-K3Y411X Series Flap Barrier Quick Start Guide Remote control and management Online/offline operation LED indicates the entrance/exit and passing status Barrier is in open status when powered down; If the device is installed with supercapacitor, the barrier remains open when powered down Fire alarm passing When the fire alarm is triggered, the barrier will be open automatically for emergency evacuation Valid passing duration settings System will cancel the passing permission if a person does not pass through the lane within the valid passing duration Opens/Closes barrier according to the schedule template 2 DS-K3Y411X Series Flap Barrier Quick Start Guide Chapter 2 System Wiring The preparation before installation and general wiring. Steps 1. Draw a central line on the installation surface of the left or right pedestal. 2. Draw other parallel lines for installing the other pedestals. Note The distance between the nearest two line is L+200 mm. L represents the lane width. 3. Slot on the installation surface and dig installation holes according to the hole position diagram. 4. Bury cables. Each lane buries 1 network cable and 1 high voltage cable. For details, see the system wiring diagram below. Figure 2-1 Hole Position Diagram 3 DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 2-2 System Wiring Diagram (General Wiring) Note The supplied interconnecting cable length is 3.75 m. If you need a longer one, you can buy a new accessory. The suggested inner diameter of the low voltage conduit is larger than 30 mm. If you want to bury both of the AC power cord and the low voltage cable at the entrance, the two cables should be in separated conduits to avoid interference. If more peripherals are required to connect, you should increase the conduit diameter or bury another conduit for the external cables. The external AC power cord should be double-insulated. The network cable must be CAT5e or the network cable has better performance. And the suggested network cable length should be less than 100 m. 4 DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 2-3 Wire Face Recognition Terminal Note The face recognition terminal installed on the left pedestal will gain power from the sub switch, which should connect to high voltage. The suggested inner diameter of the low voltage conduit is larger than 30 mm. The supplied interconnecting cable length is 3.75 m. If you need a longer one, you can extend the cable by yourself. If you want to bury both of the AC power cord and the low voltage cable at the entrance, the two cables should be in separated conduits to avoid interference. If more peripherals are required to connect, you should increase the conduit diameter or bury another conduit for the external cables. The external AC power cord should be double-insulated. The network cable must be CAT5e or the network cable has better performance. And the suggested network cable length should be less than 100 m. 5 DS-K3Y411X Series Flap Barrier Quick Start Guide Chapter 3 Installation 3.1 Disassemble Pedestals Before installation, you should use the key to open the pedestals. View the pictures below to find the lock holes. Figure 3-1 Lock Holes 6 DS-K3Y411X Series Flap Barrier Quick Start Guide Note Please check and avoid metal pieces dropped into the high and low voltage modules, which will cause short circuit. 3.2 Install Pedestals Before You Start Prepare for the installation tools, check the device and the accessories, and clear the installation base. Steps Note The device should be installed on the concrete surface or other non-flammable surfaces. For opening the pedestal conveniently, make sure the distance between the pedestal and the wall should be more than 10 mm. The dimension is as follows. 7 DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 3-2 Dimension 1. Prepare for the installation tools, check the components, and prepare for the installation base. 2. Drill holes on the ground according to the installation holes on the pedestals and insert the expansion sleeves. 3. According to the entrance and exit marks on the pedestals, move the pedestals to the corresponded positions. Note Make sure the installation holes on the pedestals and the base are aligned with each other. 4. Secure the pedestals with expansion bolts. Note The suggested expansion bolt's size is M12*150. You can change or transform the expansion bolt according to your actual needs. But make sure that do not drill through the floor. If the floor is too soft to install, it is suggested to apply the construction adhesive to strengthen. Do not immerse the pedestal in the water. In special circumstances, the immersed height should be no more than 150 mm. The installation footprint is as follows:
8 DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 3-3 Installation Footprint 5. After installation, assemble the components and screws back to the pedestal in reverse order
(except for protective sheets). 9 DS-K3Y411X Series Flap Barrier Quick Start Guide Chapter 4 General Wiring Note After maintenance, you should close the water-proof cover over the high/low voltage module. When you should maintain or disassemble the high voltage modules, you should remove the entire high voltage modules and maintain it outside the turnstile. You should unplug the cables that connected to the peripherals before maintenance to avoid destroy of the device. 4.1 Components Introduction By default, basic components of the turnstile are connected well. The pedestals can communicate by wiring the interconnecting cables. And the turnstile supports wiring the AC electric supply for the whole system's power supply. Note The voltage fluctuation of the electric supply is between 100 VAC and 240 VAC, 50 to 60 Hz. The picture displayed below describes each component's position on the turnstile. Note The diagram is for reference only. 10 DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 4-1 Components Diagram 1 Note The reinstalled supercapacitor needs to be powered on for at least 3 minutes before it can work normally. The picture displayed below describes the IR adapter and the IR sending/receiving board and their corresponding number on the pedestal. 11 DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 4-2 Components 2 Note If the turnstile contains two lanes, standing at the entrance position, the IR boards on the left pedestal are the IR sending boards. The IR boards on the right pedestal are the IR receiving boards. The IR boards on the left side of the middle pedestal are the IR receiving boards, while the IR boards on the right side of the middle pedestal are the IR sending boards. 4.2 Wiring Electric Supply Wire electric supply with the switch in the pedestal. Terminal L and terminal N are on the switch, while terminal PE should connect to a ground wire (yellow and green wire). 12 DS-K3Y411X Series Flap Barrier Quick Start Guide Note The cable bare part should be no more than 8 mm. It is suggested that you can immerse the bare part into the liquid tin. If possible, wear an insulation cap at the end of the bare cable. Make sure theres no bare copper or cable after the wiring. The Terminal L and the Terminal N cannot be wired reversely. Do not wire the input and output terminal reversely. To avoid people injury and device damage, when testing, the ground resistance of the equipotential points should not be larger than 2 Use the device in conjunction with an UPS. 13 DS-K3Y411X Series Flap Barrier Quick Start Guide 4.3 Wire Interconnecting Cable You should use interconnecting cables to connect the main lane board and the sub lane board for components communication. Note The right/middle pedestal contains an interconnecting cable, including one network cable (5.5 m) and one 2-core cable. The picture displayed below describes the cable hole's position on the pedestals. Figure 4-3 Cable Hole of Interconnecting Cable If the slotting position is at the middle of the pedestal, you can wire the cable through the pedestal, and the side cable hole. For details about the wiring instructions, see the picture below:
14 DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 4-4 Wiring Method of Slotting in Middle Follow the instructions below to connect the interconnecting cable. 15 DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 4-5 Connect Interconnecting Cable 4.4 Face Recognition Terminal Power Supply Wiring (Optional) If connect to face recognition terminals, the face recognition terminals of right pedestal and middle pedestal (entrance) will power supplied by 12 V terminal on left side of the pedestal. The face recognition terminal of left pedestal and middle pedestal (exit) will power supplied by 12 V terminal of the power adaptor of the right pedestal. The sub lane control board will power supplied by the power adaptor. For details about the wiring, see the picture below:
16 DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 4-6 Face Recognition Terminal Power Supply Wiring 4.5 Terminal Description The lane controller contains main lane controller and sub lane controller, which controls the IR beams, motor, and other components' work. 4.5.1 UART Related Terminal and Position View the UART position on the lane control board and the access control board. You can also view the UART related terminals and DIP switch information. The reserved UART terminal positions in the turnstile and their corresponded UART No. are as follows:
17 DS-K3Y411X Series Flap Barrier Quick Start Guide Note The diagram is for reference only. Figure 4-7 Interface and Corresponded UART No. The UART related terminals are on the access control board and BUS of the lane control board. You can switch between the RS-232 and the RS-485 communication modes via DIP switch. The UART and the related DIP switch information is as follows:
18 DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 4-8 UART No. Description Table 4-1 UART Related Position/Terminals/DIP Switch Introduction UART No. Related Terminals Terminal Position DIP Switch No. Function BUS of Main Lane Control Board UART1 485A/232A Note External card reader is recommended to access. UART3 485C+/232C+
Access Control Board 1 to 3 4 to 6 7 8 1 to 3 ON: UART1 is RS-
232A Interface ON: UART1 is RS-
485A Interface Reserved Reserved ON: UART3 is RS-
232C Interface 19 DS-K3Y411X Series Flap Barrier Quick Start Guide UART No. Related Terminals Terminal Position DIP Switch No. Function Note External card reader is recommended to access. 485C-/232C-
UART5 485E+/232E+
Note External card reader is recommended to access. 485E-/232E-
UART6 485F+/232F+
Note Face recognition terminal is recommended to access. UART7 UART8 485F-/232F-
232G+/232G-
232H+/232H-
4 to 6 7 8 1 to 3 4 to 6 7 8 1 to 3 4 to 6 7 8
BUS of Sub Lane Control Board BUS of Sub Lane Control Board Access Control Board Access Control Board ON: UART3 is RS-
485C Interface Reserved Reserved ON: UART3 is RS-
232E Interface ON: UART3 is RS-
485E Interface Reserved Reserved ON: UART3 is RS-
232F Interface ON: UART3 is RS-
485F Interface Reserved Reserved
4.5.2 Main Control Board Terminal Description The main lane control board contains power input, BUS interface, interconnecting interface, supercapacitor interface, barrier position control board interface and motor drive interface. The picture displayed below is the main control board diagram. 20 DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 4-9 Main Control Board Terminal 4.5.3 Sub Control Board Terminal Description The sub lane control board contains power input, BUS interface, interconnecting interface, supercapacitor interface, barrier position control board interface and motor drive interface. The picture displayed below is the sub control board diagram. 21 DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 4-10 Sub Control Board Terminal 4.5.4 BUS Terminal Description You can connect the lane controller light board, fan, TAMPER, lane control board, card reader, face recognition terminal, QR code scanner, etc. via the BUS terminal. Note Part of the wiring has been completed at the factory, please connect according to actual needs. Table 4-2 BUS Terminal in Main Lane Controller Terminal Name Description Lane Controller Light Board 1 Connects lane controller light board 1 Lane Controller Light Board 2 Connects lane controller light board 2 Fan TAMPER1 TAMPER2 Connects fan Connects TAMPER1 Connects TAMPER2 Lane Controller Board Connects main lane controller board 5 V IR Adaptor Reserved Connects IR adaptor 22 DS-K3Y411X Series Flap Barrier Quick Start Guide Terminal Name Description UART 1 Note External card reader is recommended to access. Red 12 V: connects 12 VDC power supply terminal Yellow 485A/232A+: card reader RS-485A+/RS-232A+ access terminal Blue 485A/232A-: card reader RS-485A-/RS-232A- access terminal Black GND: grounding Table 4-3 BUS Terminal in Sub Lane Controller (Left Pedestal) Terminal Name Description Lane Controller Light Board 1 Connects lane controller light board 1 Lane Controller Light Board 2 Connects lane controller light board 2 Fan TAMPER1 TAMPER2 Connects fan Connects TAMPER1 Connects TAMPER2 Lane Controller Board Connect sub lane controller board 5 V IR Adaptor UART 5 Note External card reader is recommended to access. UART 6 Note External face recognition terminal is recommended to access. Reserved Connects IR adaptor Red 12 V: connects 12 VDC power supply terminal Yellow 485E/232E+: card reader RS-485E+/RS-232E+ access terminal Blue 485E/232E-: card reader RS-485E-/RS-232E- access terminal Black GND: grounding Red 12 V: connects 12 VDC power supply terminal Yellow 485F/232F+: card reader RS-485F+/RS-232F+ access terminal Blue 485F/232F-: card reader RS-485F-/RS-232F- access terminal Black GND: grounding 23 DS-K3Y411X Series Flap Barrier Quick Start Guide Table 4-4 BUS Terminal in Sub Lane Controller (Middle Pedestal) Terminal Name Description Lane Controller Light Board 1 Connects lane controller light board 1 Lane Controller Light Board 2 Connects lane controller light board 2 Lane Controller Board Connect sub lane controller board 5 V IR Adaptor UART 5 Note External card reader is recommended to access. UART 6 Note External face recognition terminal is recommended to access. Reserved Connects IR adaptor Red 12 V: connects 12 VDC power supply terminal Yellow 485E/232E+: card reader RS-485E+/RS-232E+ access terminal Blue 485E/232E-: card reader RS-485E-/RS-232E- access terminal Black GND: grounding Red 12 V: connects 12 VDC power supply terminal Yellow 485F/232F+: card reader RS-485F+/RS-232F+ access terminal Blue 485F/232F-: card reader RS-485F-/RS-232F- access terminal Black GND: grounding 4.5.5 Access Control Board Terminal Description Access control board is mainly used for authority identification in places with high security levels such as public security or judicial place, external device accessing, and communication with the upper platform and lane controller. 24 DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 4-11 Access Control Board Terminal Table 4-5 Access Control Board Terminal Description Access Control Board Terminal Description Power Output 1
+12 V 12 VDC Power Output
G Grounding RS-485 Interface RS-485 C+
Connect to Card Reader RS485+
RS-485 C-
Connect to Card Reader RS485-
GND Grounding RS-485 card reader ID factory DIP is 1 and 3. 1 represents the passage entrance, and 3 represents 25 DS-K3Y411X Series Flap Barrier Quick Start Guide Access Control Board Terminal Description the passage exit. UART 1 in the main control board corresponds to the entrance card reader, and UART 5 in the main control board corresponds to the exit card reader. If the user has configured a guest card, the exit needs to be connected to two card readers, one with the DIP 4 and the other with the DIP 3. The card reader 3 and the card receiver are used together, the ordinary user swipes the card on the card reader 4, and the guest user swipes the card on the 26 DS-K3Y411X Series Flap Barrier Quick Start Guide Access Control Board Terminal Description card reader 3. This is the RS-485 interface, which cannot be switched by dialing. Power Output 2 5 V 5 VDC Power Output
RS-232 Interface G G Grounding Grounding RS-232 G-
Connect to RS-232G-
RS-232 G+
Connect to Card Reader RS-232G+
G Grounding RS-232 H-
Connect to RS-232H-
RS-232 H+
Connect to Card Reader RS-232H+
This is the RS-232 interface, which cannot be switched by dialing. By default, there is no QR code scanner on the left pedestal of the device entrance. If you need to connect an additional QR code scanner, you need to connect it through the RS-232 interface here. After the cable is connected to the RS-232 interface, it 27 DS-K3Y411X Series Flap Barrier Quick Start Guide Access Control Board Terminal Description passes through the embedded pipe and connects with the QR code on the left. 24 VDC Power Input
Power Input Event Input
+24 V GND C1 G C2 Grounding Event Alarm Input 1 Grounding Event Alarm Input 2 The event alarm input hardware interface is remaining open, and only supports access to remaining open signals, which can be linked to the host buzzer output, card reader buzzer output, alarm relay output, door open relay output, etc.
If necessary, the door lock relay can be used to control the third-party barrier switch. Exit Button Door Lock (Relay) B2 G B1 D1-
D1+
Door 2 Signal Input Grounding Door 1 Signal Input Door 1 Relay Output (Dry Contact) 28 DS-K3Y411X Series Flap Barrier Quick Start Guide Access Control Board Terminal Description D2-
D2+
Door 2 Relay Output (Dry Contact) Alarm Output NO/NC1 Alarm Output Relay 1 (Dry Contact) COM1 NO/NC2 COM2 Alarm Output Relay 2 (Dry Contact) Loudspeaker
Connect to loudspeaker Network Interface LAN Network Accessing Fire Input XF G Fire input Grounding 29 D1 controls the door opening for ordinary entrance, and D2 controls the door opening for ordinary exit. If necessary, the door lock relay can be used to control the third-party barrier switch. D1 controls the door opening for ordinary entrance, and D2 controls the door opening for ordinary exit. The alarm output supports switch output. The alarm output supports switch output.
DS-K3Y411X Series Flap Barrier Quick Start Guide Note You can swtich between RS-485 and RS-232 via the DIP switch on the access control board. For details about DIP switch and swiching method, see Access Control Board UART Description . For details about DIP switch operation, see DIP Switch Description . 4.5.6 Access Control Board UART Description You can set the device mode, switch the communication mode of the corresponding UART, and initialize the device through the DIP on the access control board. The DIP switch of the access control board is shown in the figure below:
Note The diagram is for reference only. 30 DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 4-12 DIP Switch on Access Control Board DIP A can set the device mode, DIP 2 to 5 can set the RS-485/RS-232 interface, and DIP B can also be used to initialize the device. The UART corresponding to the DIP Switch is shown in the figure below:
31 DS-K3Y411X Series Flap Barrier Quick Start Guide The corresponding functions of different DIP Switch are described as follows:
Figure 4-13 UART No. Description No. Device Mode UART No. Function Binary Value DIP A 1 to 2: Work Mode
Normal Mode Test Mode 32 DS-K3Y411X Series Flap Barrier Quick Start Guide No. Device Mode UART No. Function Binary Value 3: Memory Mode 4: Keyfob Paring Mode 5 to 8: Passing Mode Enable Memory Mode Disable Memory Mode Enable Keyfob Paring Mode Disable Keyfob Paring Mode Controlled Bi-
direction Controlled Entrance and Prohibit Exit Controlled Entrance and Free Exit Free Bi-direction Free Entrance and Controlled Exit Free Entrance and Prohibit Exit Prohibited Bi-
direction 33 DS-K3Y411X Series Flap Barrier Quick Start Guide No. Device Mode UART No. Function Binary Value DIP B DIP C DIP D DIP E 1 to 3 4 to 6 7 8 1 to 3 4 to 6 7 8 1 to 3 4 to 6 7 8 1 to 3 4 to 6 7 8 Prohibit Entrance and Controlled Exit Prohibit Entrance and Free Exit ON: UART 5 is RS-
232E Interface ON: UART 5 is RS-
485E Interface Reserved Default is OFF. You can dial to ON for initial operation ON: UART 6 is RS-
232F Interface ON: UART 6 is RS-
485F Interface Reserved Reserved ON: UART 1 is RS-
232A Interface ON: UART 1 is RS-
485A Interface Reserved Reserved ON: UART 3 is RS-
232C Interface ON: UART 3 is RS-
485C Interface Reserved Reserved
UART 5
UART 6
UART 1
UART 3
34 DS-K3Y411X Series Flap Barrier Quick Start Guide Note For proper communication between turnstile and peripherals, DIP Switch No. 1 to 3, 4 to 6, 7, and 8 of DIP B, DIP C, DIP D, and DIP E cannot be turned ON at the same time. The reserved UART terminal positions in the turnstile and their corresponded UART No. are as follows:
Note The diagram is for reference only. Figure 4-14 Interface and Corresponded UART No. 35 DS-K3Y411X Series Flap Barrier Quick Start Guide 4.5.7 RS-485 Wiring Note The RS-485 interfaces are for connecting ID card reader, IC card reader, card reader, card recycler, text screen, and face recognition terminal. Take the wiring of RS-485 card reader as an example. For details about text screen, see Configuring Screen Parameters in User Manual of iVMS-4200 AC Client Software. 36 DS-K3Y411X Series Flap Barrier Quick Start Guide 4.5.8 RS-232 Wiring Note Access control board of pedestal can connect QR code scanner, card recycler, text screen and face recognition terminal via RS-232 interface. For details about text screen, see Configuring Screen Parameters in User Manual of iVMS-4200 AC Client Software. Take the wiring of text screen as an example. 37 DS-K3Y411X Series Flap Barrier Quick Start Guide 4.5.9 Barrier Control Wiring By default, the barrier has connected with the access control board. The lane control board can control the barrier status. If possible, the device can connect with a third party lane control board to control the third party barriers. Interface D1 controls barrier opening for entrance, while interface D2 controls barrier opening for exit. Note Use the jumper cap to switch the relay status. For details, see Barrier Control Relay Output Mode . Entering Wiring Exiting Wiring 38 DS-K3Y411X Series Flap Barrier Quick Start Guide 4.5.10 Alarm Output Wiring Note For details about changing the relay output status via the jumper cap, see Alarm Relay Output Mode (NO/NC) . 39 DS-K3Y411X Series Flap Barrier Quick Start Guide Chapter 5 Device Settings After installation and wiring completed, the turnstile will learn the open and closed position automatically. After the learning, the turnstile is in the normal mode. You can also set the turnstile to test mode, passing mode and memory mode, pair the keyfob, initialize the hardware, switching between RS-485 communication mode and RS-232 communication mode, and view relay output NO/NC diagram by setting the DIP switch on the access control board. Normal Mode: The device will work properly. Test Mode: Test mode is the same as the normal mode except that the device cannot report the alarm, the event, or the people counting information to the center. Passing Mode: There are 9 passing modes, including controlled bi-direction, controlled entrance and prohibited exit, controlled entrance and free exit, free bi-direction, free entrance and controlled exit, free entrance and prohibited exit, prohibited bi-direction, prohibited entrance and free exit. Memory Mode: By default, the memory mode is enabled. When multiple cards are presented and authenticated, it allows multiple persons passing through the lane. When it counts the passing people number is equal to the card presented times, or no person passing through the lane after the last person passing, the barriers will be closed. Note You can also set the DIP switch on the access control board to control the entrance and exit controlling type, keyfob pairing, etc. For details about the DIP switch value, see Access Control Board UART Description . 5.1 Pair Keyfob (Optional) Pair the remote control to the device through DIP switch to open/close the barrier remotely. Before You Start Ask our technique supports or sales and purchase the keyfob. Steps Note Up to 32 keyfobs can be added to the turnstile. You can set the keyfob to one-to-one mode or one-to-many mode via the DIP switch on the keyfob. Here takes one-to-one mode as an example to explain. For one-to-many mode, see the keyfob user manual. One-to-One Mode 40 DS-K3Y411X Series Flap Barrier Quick Start Guide By default, the keyfob is in one-to-one mode. The keyfob's DIP switch is towards 1 (OFF). The keyfob can control only one turnstile. One-to-Many Mode The keyfob's DIP switch is ON. In this mode, the keyfob can control multiple turnstiles. 1. Power off the turnstile. 2. Set the No.4 switch of the DIP Switch on the access control board to the ON side. 3. Power on the turnstile and it will enter the keyfob pairing mode. 4. Hold the Close button for more than 10 seconds. Or pair turnstile and keyfob in the client software, see Manage Keyfob User of the user manual for more details. The keyfob's indicator of the will flash twice if the pairing is completed. 5. Set the No.4 switch to OFF, and reboot the turnstile to take effect. Note Only one turnstile can pair the keyfob. If multiple turnstiles are in the pairing mode, the keyfob will select only one of them to pair. For details about DIP switch value and meaning, see Access Control Board UART Description . 6. Optional: Go to System User Keyfob User on the remote control page of the client software to delete the keyfob. 5.2 Initialize Device Steps 1. Set the No.8 switch of the DIP 2 Switch on the access control board to the ON side. 41 DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 5-1 Initialization Jumper Cap 2. Disconnect the power and reboot the device. 3. When the beep stopped, set the No.8 switch to the OFF side, and reboot the turnstile to take effect. 4. Disconnect the power and power on the device again. Caution The initialization of the device will restore all the parameters to the default setting and all the device events are deleted. Note Make sure no persons are in the lane when powering on the device. 42 DS-K3Y411X Series Flap Barrier Quick Start Guide 5.3 Switch Relay Output Mode (NO/NC) 5.3.1 Barrier Control Relay Output Mode The jumper cap of the barrier control relay on the access control board is as below:
Figure 5-2 Jumper Cap Location (Barrier Control Relay Output Mode) The jumper cap position of barrier opening (NO) is as below:
43 DS-K3Y411X Series Flap Barrier Quick Start Guide The jumper cap position of barrier closing (NC) is as below:
Figure 5-3 Barrier Opening (NO) Figure 5-4 Barrier Closing (NC) Note The default status is NC. 5.3.2 Alarm Relay Output Mode (NO/NC) The jumper cap of the alarm relay on the access control board is as below:
44 DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 5-5 Jumper Cap Location (Alarm Relay Output Mode) The jumper cap position of alarm opening (NO) is as below:
The jumper cap position of alarm closing (NC) is as below:
Figure 5-6 Alarm Opening (NO) 45 DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 5-7 Alarm Closing (NC) Note The default status is NO. 46 DS-K3Y411X Series Flap Barrier Quick Start Guide Chapter 6 Activation You should activate the device before the first login. After powering on the device, the system will switch to Device Activation page. Activation via the device, SADP tool and the client software are supported. The default values of the device are as follows:
The default IP address: 192.0.0.64 The default port No.: 8000 The default user name: admin 6.1 Activate via SADP SADP is a tool to detect, activate and modify the IP address of the device over the LAN. Before You Start Get the SADP software from the supplied disk or the official website http://
www.hikvision.com/en/ , and install the SADP according to the prompts. The device and the PC that runs the SADP tool should be within the same subnet. The following steps show how to activate a device and modify its IP address. For batch activation and IP addresses modification, refer to User Manual of SADP for details. Steps 1. Run the SADP software and search the online devices. 2. Find and select your device in online device list. 3. Input new password (admin password) and confirm the password. Caution STRONG PASSWORD RECOMMENDED-We highly recommend you create a strong password of your own choosing (using a minimum of 8 characters, including upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product. And we recommend you reset your password regularly, especially in the high security system, resetting the password monthly or weekly can better protect your product. Note Characters containing admin and nimda are not supported to be set as activation password. 4. Click Activate to start activation. 47 DS-K3Y411X Series Flap Barrier Quick Start Guide Status of the device becomes Active after successful activation. 5. Modify IP address of the device. 1) Select the device. 2) Change the device IP address to the same subnet as your computer by either modifying the IP address manually or checking Enable DHCP. 3) Input the admin password and click Modify to activate your IP address modification. 6.2 Activate Device via Client Software For some devices, you are required to create the password to activate them before they can be added to the software and work properly. Steps Note This function should be supported by the device. on the right of Device Management and select Device. 1. Enter the Device Management page. 2. Click 3. Click Online Device to show the online device area. The searched online devices are displayed in the list. 4. Check the device status (shown on Security Level column) and select an inactive device. 5. Click Activate to open the Activation dialog. 6. Create a password in the password field, and confirm the password. 48 DS-K3Y411X Series Flap Barrier Quick Start Guide Caution The password strength of the device can be automatically checked. We highly recommend you change the password of your own choosing (using a minimum of 8 characters, including at least three kinds of following categories: upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product. And we recommend you change your password regularly, especially in the high security system, changing the password monthly or weekly can better protect your product. Proper configuration of all passwords and other security settings is the responsibility of the installer and/or end-user. Note Characters containing admin and nimda are not supported to be set as activation password. 7. Click OK to activate the device. 49 DS-K3Y411X Series Flap Barrier Quick Start Guide Appendix A. DIP Switch Description The DIP switch is on the main lane control board. The left side to the right side is from the low bit to the high bit. When the switch is towards ON, it means the switch is enabled, otherwise, the switch is off. If you set the DIP switch like the figure displayed below, its binary value is 00001100, and its decimal value is 12. 50 DS-K3Y411X Series Flap Barrier Quick Start Guide Appendix B. Event and Alarm Type Event Alarm Type Tailgating Visual and Audible Reverse Passing Visual and Audible Force Accessing None Climb over Barrier Visual and Audible Overstay Visual and Audible Passing Timeout None Intrusion Visual and Audible Free Passing Authentication Failed Visual Barrier Obstructed None 51 DS-K3Y411X Series Flap Barrier Quick Start Guide Appendix C. Table of Audio Index Related Content Index Content Authenticated. Card No. does not exist. Card No. and fingerprint mismatch. Climbing over the barrier. Reverse passing. Passing timeout. Intrusion. Force accessing. Tailgating. No permissions. Authentication time out. Authentication failed. Expired card. Stay out of time. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 52 DS-K3Y411X Series Flap Barrier Quick Start Guide Appendix D. Error Code Description The swing barrier will display the error code on the seven-segment display if error occurred. Refer to the table below to find the description of each number. Error Reason Code Error Reason Code Normal Working Upper First IR Beam Triggered Upper Second IR Beam Triggered 00 01 02 Upper Third IR Beam Triggered 03 Upper Fourth IR Beam Triggered Upper Fifth IR Beam Triggered Upper Sixth IR Beam Triggered Upper Seventh IR Beam Triggered Upper Eighth IR Beam Triggered 04 05 06 07 08 Lower Fifth IR Beam Triggered Lower Sixth IR Beam Triggered Lower Seventh IR Beam Triggered Lower Eighth IR Beam Triggered 17 18 19 20 Lower Ninth IR Beam Triggered 21 Lower Tenth IR Beam Triggered 22 Lower Eleventh IR Beam Triggered Lower Twelfth IR Beam Triggered 23 24 Light Board Offline (Entrance) 49 Upper Ninth IR Beam Triggered 09 Light Board Offline (Exit) Upper Tenth IR Beam Triggered 10 IR Adapter Offline (Up) Upper Eleventh IR Beam Triggered Upper Twelfth IR Beam Triggered Lower First IR Beam Triggered Lower Second IR Beam Triggered 11 12 13 14 IR Adapter Offline (Low) CAN Bus Exception Not Studying Obstruction Lower Third IR Beam Triggered 15 Exceeding Studying Range Lower Fourth IR Beam Triggered 16 Motor Exception 50 51 52 53 54 55 56 57 53 DS-K3Y411X Series Flap Barrier Quick Start Guide Appendix E. Communication Matrix and Device Command Communication Matrix Scan the following QR code to get the device communication matrix. Note that the matrix contains all communication ports of Hikvision access control and video intercom devices. Figure E-1 QR Code of Communication Matrix Device Command Scan the following QR code to get the device common serial port commands. Note that the command list contains all commonly used serial ports commands for all Hikvision access control and video intercom devices. Figure E-2 Device Command 54 UD23418B-B
1 | Label | ID Label/Location Info | 203.16 KiB | September 28 2021 |
HIKVISION Flap Barrier Model: DS-K3Y411X-M1/M SN: 12345678 Date: 07/2021 WMI VU IU, xcctmoroxaverxanon UP: 100-240V~,50/60Hz, 1.92A-0.88 Contains FCC ID:2ADTD-K1102AMK Made in China MPg-Dr60 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1)this device may not cause harmful interference, and
(Qthis device must accept any interference received, Including interference that may cause undesired operation. =
Manufacturer: Hangzhou Hikvision Digital Technology Co.,Ltd. Address: No.555 Qlanmo Road, Binjiang District, Hangzhou 310052, China HIKVISION Flap Barrier Model: DS-K3Y411X-M1/E SN: 12345678 Date: 07/2021 UI IITOMTNH ULIMIT] sccianoroseversann UP: 100-240V~,50/60Hz, 1.92A-0.8A Contains FCC ID:2ADTD-K1102AEK Made in China MPg-Dr60 This device complies wth Part 15 ofthe FCC Rules.
(Operation is subjactto the following two conditions:
({)tie device may not eause harmful interference, and
(2ihis device must accept any interference received, including interference that may cause undesired operation. =
Manufacturer: Hangzhou Hikvision Digital Technology Co,Ltd. Address: No.555 Gianmo Road, Binjiang District, Hangzhou 310052, Chi
1 | Applicant Declaration Letter | Cover Letter(s) | 117.71 KiB | September 28 2021 |
SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia 30024 United States Applicant Declaration Applicant Legal Business Name Hangzhou Hikvision Digital Technology Co., Ltd. Address Grantee Code FCC ID No. 555 Qianmo Road, Binjiang District Hangzhou 310052, China 2ADTD 2ADTD-K3Y411X-M1M Authorized Contact Name Long Cheng Contact Email Contact Phone chenglong6@hikvision.com
+8618969187825 I, the undersigned, certify that I am an authorized signatory for the Applicant and therefore declare;
a) b) c) d) e) in accordance with 47CFR2.911(d), all of the statements herein and the exhibits attached hereto are true and correct to the best of my knowledge and belief. in accepting a Grant of Equipment Authorization issued by a TCB, under the authority of the FCC, as a result of the representations made in this application, the Applicant is responsible for:
labeling the equipment with the exact FCC ID as specified in this application,
(1)
(2) compliance statement labeling pursuant to the applicable rules,
(3) compliance of the equipment with the applicable technical rules, if the Applicant is not the actual manufacturer of the equipment, appropriate arrangements have been made with the manufacturer to ensure that production units of this equipment will continue to comply with the FCCs technical requirements. in accordance with 47 CFR 2.909 and KDB394321, the Applicant has read, understood and agrees to accept that they are the responsible party and agree to abide by their responsibilities as specified under 47 CFR 2.909 and KDB394321. in accordance with ISO17065, FCC KDB641163, FCC KDB610077, KDB394321 and RSP-100, the Applicant has read, understood, accepts and agrees to abide by the post market surveillance requirements.
(1)
(2)
(3) the Applicant understands, accepts and agrees that a sample may be requested for surveillance testing. the Applicant shall make provisions to always have a production sample available upon request by SGS, FCC and/or ISED. the Applicant shall, upon request by SGS, at the Applicants expense, provide a production sample of the requested product to SGS, FCC and/or ISED as instructed. The sample shall include all support devices, cables, software, accessories or other hardware or software required for evaluation, review, certification and audit surveillance of products certified by SGS. f) neither the Applicant nor any party to the application is subject to a denial of Federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862 because of a conviction for possession or distribution of a controlled substance. See 47CFR 1.2002(b) for the definition of a party for these purposes. g) the Applicant has read, understood, accepts and agrees to abide by the SGS North America, Inc.(TCB) terms and conditions. Link to CFRs: https://www.fcc.gov/wireless/bureau-divisions/technologies-systems-and-innovation-division/rules-regulations-title-47 Link to KDBs: https://apps.fcc.gov/oetcf/kdb/index.cfm Link to RSP-100: https://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf01130.html Date:2021/09/16 Applicant Signature:
Print Name:
Title:
*NOTE: This declaration cannot be signed by an Agent, it shall be signed by an authorized person listed in the FCC database Long Cheng Testing & Certification Engineer Applicant Declaration Rev:0.0
1 | Auth letter | Cover Letter(s) | 27.36 KiB | September 28 2021 |
Hangzhou Hikvision Digital Technology Co., Ltd. TO:
Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Regarding: FCC ID: 2ADTD-K3Y411X-M1M To whom it may concern:
Date: 2021-09-16 We, the undersigned, hereby authorize Parlam Zhan to act on our behalf in all manners relating to application for equipment authorization with respect to the FCC ID above, including signing of all documents relating to these matters. Any and all acts carried out by the agent on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Where our agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by SGS North America, Inc., still resides with Hangzhou Hikvision Digital Technology Co., Ltd. This authorization is valid until further written notice from the applicant. Name (Printed): Long Cheng Title: Testing & Certification Engineer Signature:
On behalf of Company: Hangzhou Hikvision Digital Technology Co., Ltd. Telephone: +8618969187825
1 | Confidentiality FCC | Cover Letter(s) | 87.40 KiB | September 28 2021 |
Hangzhou Hikvision Digital Technology Co., Ltd. To:
SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia United States From: Hangzhou Hikvision Digital Technology Co., Ltd. No. 555 Qianmo Road, Binjiang District, angzhou 310052, China Regarding:
Confidentiality Request regarding application for FCC ID: 2ADTD-K3Y411X-M1M LONG TERM CONFIDENTIALITY Pursuant to 47 CFR Section 0.459 and 0.457 of the commissions rules, the applicant hereby request confidential treatment of the documents listed below, associated with the certification application referenced above. Schematic(s) Block Diagrams Operational Descriptions The documents above contain proprietary information not released to the public. Public disclosure of this information may prove harmful to the business of the applicant. Sincerely, Signature:
Printed Name (on file with the FCC associated with the Grantee Code): Long Cheng Title: Testing & Certification Engineer Company Name: Hangzhou Hikvision Digital Technology Co., Ltd.
1 | MCL | Cover Letter(s) | 145.66 KiB | September 28 2021 |
Hangzhou Hikvision Digital Technology Co., Ltd. Current Date : 2021-09-16 To:
SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. No. 588 West Jindu Road, Songjiang District, Shanghai, China. 201612 Dear Sir/Madam, Subject: Declaration Letter about Identity of Products
*WE (Hangzhou Hikvision Digital Technology Co., Ltd.) HEREBY DECLARED THAT Product Description Flap Barrier Model No. DS-K3Y411X-L1,DS-K3Y411X-L1/M,DS-K3Y411X-L1/E,DS-K3Y411X-L2, ,DS
-K3Y411X-L2/E,DS-K3Y411X-M1,DS-K3Y411X-M1/E,DS-K3Y411X-M2,DS-K 3Y411X-M2/M,DS-K3Y411X-M2/E,DS-K3Y411X-R,DS-K3Y411X-R/M,DS-K3 Y411X-R/E,DS-K3Y411X-L1UHK,DS-K3Y411X-L1CKV,DS-K3Y411X-L1UVS, DS-K3Y411X-L1KVO,DS-K3Y411X-L1HUN,DS-K3Y411X-L2UHK,DS-K3Y41 1X-L2CKV,DS-K3Y411X-L2UVS,DS-K3Y411X-L2KVO,DS-K3Y411X-L2HUN, DS-K3Y411X-M1UHK,DS-K3Y411X-M1CKV,DS-K3Y411X-M1UVS,DS-K3Y41 1X-M1KVO,DS-K3Y411X-M1HUN,DS-K3Y411X-M2UHK,DS-K3Y411X-M2C KV,DS-K3Y411X-M2UVS,DS-K3Y411X-M2KVO,DS-K3Y411X-M2HUN,DS-K 3Y411X-RUHK,DS-K3Y411X-RCKV,DS-K3Y411X-RUVS,DS-K3Y411X-RKVO
,DS-K3Y411X-RHUN Manufacturers Name Hangzhou Hikvision Digital Technology Co., Ltd. Manufacturers Address No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China
*Except that the model number and appearance deviation, are identical with the original product as follows:
Note1: The definition of identical should be electrically identical. A device will be considered to be electrically identical if no changes are made to the devices schematics, board layouts, component layouts, chip sets, resistors and all other electrical aspects of the device are identical. Note2: The product built into a certified module (DS-K1102AEK or DS-K1102AMK), the test data of different modules has been recorded in the report Contain modular: 2ADTD-K1102AMK DS-K3Y411X-L1/M, DS-K3Y411X-L2/M, DS-K3Y411X-M1/M, DS-K3Y411X-M2/M, DS-K3Y411X-R/M, Contain modular: 2ADTD-K1102AEK DS-K3Y411X-L1/E, DS-K3Y411X-L2/E, DS-K3Y411X-M1/E, DS-K3Y411X-M2/E, DS-K3Y411X-R/E Undefined, contains modular DS-K3Y411X-L1,DS-K3Y411X-L2, Hangzhou Hikvision Digital Technology Co., Ltd. 2ADTD-K1102AMK or contains modular DS-K3Y411X-M1DS-K3Y411X-M2, DS-K3Y411X-R, 2ADTD-K1102AEK DS-K3Y411X-L1UHK,DS-K3Y411X-L1CKV,DS-K3Y411X-L1 UVS,DS-K3Y411X-L1KVO,DS-K3Y411X-L1HUN,DS-K3Y41 1X-L2UHK,DS-K3Y411X-L2CKV,DS-K3Y411X-L2UVS,DS-
K3Y411X-L2KVO,DS-K3Y411X-L2HUN,DS-K3Y411X-M1U HK,DS-K3Y411X-M1CKV,DS-K3Y411X-M1UVS,DS-K3Y411 X-M1KVO,DS-K3Y411X-M1HUN,DS-K3Y411X-M2UHK,DS-
K3Y411X-M2CKV,DS-K3Y411X-M2UVS,DS-K3Y411X-M2K VO,DS-K3Y411X-M2HUN,DS-K3Y411X-RUHK,DS-K3Y411 X-RCKV,DS-K3Y411X-RUVS,DS-K3Y411X-RKVO,DS-K3Y 411X-RHUN Manufacturers Name ():
Hangzhou Hikvision Digital Technology Co., Ltd. Manufacturers Address):
No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China Sincerely, Signature ():
Printed Name ():
Long Cheng Position/Title ():
Testing & Certification Engineer Contact Number ():
+8618969187825
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2021-09-28 | 433.6 ~ 433.6 | DXT - Part 15 Low Power Transceiver, Rx Verified | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2021-09-28
|
||||
1 | Applicant's complete, legal business name |
Hangzhou Hikvision Digital Technology Co., Ltd.
|
||||
1 | FCC Registration Number (FRN) |
0024149825
|
||||
1 | Physical Address |
No. 555 Qianmo Road, Binjiang District
|
||||
1 |
Hangzhou, N/A
|
|||||
1 |
China
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
U******@SGS.COM
|
||||
1 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
2ADTD
|
||||
1 | Equipment Product Code |
K3Y411X-M1M
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
L******** C****
|
||||
1 | Telephone Number |
+8618********
|
||||
1 | Fax Number |
+86-5********
|
||||
1 |
c******@hikvision.com
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
SGS-CSTC Standards Technical Services Co., Ltd.
|
||||
1 | Name |
P******** Z******
|
||||
1 | Physical Address |
588 West Jindu Road, Xinqiao, Songjiang
|
||||
1 |
ShangHai, 201612
|
|||||
1 |
China
|
|||||
1 | Telephone Number |
+8621********
|
||||
1 | Fax Number |
02161********
|
||||
1 |
P******@sgs.com
|
|||||
app s | Non Technical Contact | |||||
1 | Firm Name |
SGS-CSTC Standards Technical Services Co., Ltd.
|
||||
1 | Name |
P**** Z******
|
||||
1 | Physical Address |
588 West Jindu Road, Xinqiao, Songjiang
|
||||
1 |
ShangHai, 201612
|
|||||
1 |
China
|
|||||
1 | Telephone Number |
+8621********
|
||||
1 | Fax Number |
02161********
|
||||
1 |
P******@sgs.com
|
|||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DXT - Part 15 Low Power Transceiver, Rx Verified | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Flap Barrier | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Compliance Certification Services (Kunshan) Inc.
|
||||
1 | Name |
J**** C******
|
||||
1 | Telephone Number |
+ 86-******** Extension:
|
||||
1 |
J******@sgs.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 433.60000000 | 433.60000000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC