Guidance for TT001-ZA T&H sensor Application Product Specification for TT001-ZA T&H sensor 1. Product Profile 1.1 Overview As a low-cost product solution developed by Hangzhou Tuya Information Technology Co., Ltd. based on the Zigbee module (TYZS2), the TT001-ZA T&H sensor can help clients realize mass production in a short time. 1.2 Application Framework 2. Product Specification 2.1 Basic Parameters Name:T&H sensor Model: TT001-ZA Supported mobile phone operating systems: Android 4.0+; iOS 7.0+
Battery type: 3V CR2032 1 / 5 Guidance for TT001-ZA T&H sensor Application 2.2 Technical Indexes Item Transport protocol:
Wireless frequency:
Working voltage:
Detection range:
Working current (reported):
Standby current:
Battery life:
Application scope:
Installation:
Transport distance:
Battery model:
Physical switch:
Indicator light:
2.3 Appearance Parameter Zigbee 2.4 GHz 3.0V Ambient temperature and humidity 5 mA on average (Zigbee)
<3 uA More than 12 months (calculated by 210 mAh battery) Indoor use Paste Indoor: 10 m - 30 m, outdoor: 30 m - 50 m
(It is for reference only, because parameters may vary with different application environment and transport modes.) CR2032 One One 2 / 5 Guidance for TT001-ZA T&H sensor Application 3. Product Features Indicator Light and Status Switching Description The blue light is steady on for 5s The blue light fast flashes (200 ms) The blue light is steady off The blue light is steady off 3.1 Item Power on Distribution network state Working mode Data report 3.2 Data report Frequency Report frequency: The ambient temperature and humidity are detected every 5 minutes. When the temperature change is over 0.6C and the humidity change is over 6%, data will be reported. Temperature detection scope: -20C to 60C (subject to the product working temperature) Relative humidity detection scope: 0% to 100% (no condensation) 3.3 Reset Mode Long press the button of the device with a reset pin for 5s to make the blue indicator light fast flash, thus initiating reset and entering the distribution network mode. After ensuring that distribution network is available for the gateway, use the mobile phone APP to connect with the device. 3.4 Change Batteries Open the battery cap with a coin to change batteries. Please purchase CR2032 batteries with guaranteed quality. 3.5 Logic of Distribution Network Report 3 / 5 Guidance for TT001-ZA T&H sensor Application 3.6 FunctionalCharacteristics Item Activity detection Description Monitor the temperature and humidity data in your room. Push After message push is enabled on the APP, if the data exceeds the threshold, the cloud will push a message to the mobile phone through the Zigbee gateway. Battery energy detection Battery energy report Linkage Add a product for linkage through the APP (e.g. intelligent light or curtain) and configure options. When the set threshold is reached, turn on/off the intelligent light or open/close the curtain. Seven-day history browse is supported. History 3.7 Environmental Parameters and Notes Working temperature: -20C to 60C Relative humidity: 0% to 100% (no condensation) Placement: Avoid environment with smog or water like bathrooms and kitchens. Installation: Pasting 3.8 Control Panel and APP The control panel uses the public version, and supports Tuya APP and OEM APP. 4 / 5 Guidance for TT001-ZA T&H sensor Application 4. Product Packaging 4.1 PackagingMaterials 1. Temperature and humidity sensor 2. Reset pin 3. Manual 4. Battery FCC Statement Any Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation. FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment .This equipment should be installed and operated with minimum distance 20cm between the radiator& your body. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. 5 / 5