TCLWRQS1 Datasheet Global Intelligent Platform Product Manual Tuya TCLWRQS1 Wi-Fi Module Version: 2.0.0 Date: 2020-2-26 No:
1. Product Overview TCLWRQS1 is a Wi-Fi module developed by Hangzhou Tuya Inc ,which takes the communication with 5V TTL signal . It consists of a highly integrated RF chip (RTL8710BN) external Flash IC and DC-DC components, It embedded with Wi-Fi network protocol stack and robust library functionsBesides it also contains with a low-power ARM-CM4 MCU, 2 MB flash memory, 256KB SRAM, WLAN MAC1T1R WLAN and rich peripheral resources. Embedded with32 bit CPU, which can be used as an application processor Dominant frequency: up to 125 MHz 1.1 Features Working voltage: 5 V Peripherals: 1*UART (5V TTL) Wi-Fi connectivity 802.11b/g/n/HT20/HT40 Channels 1 to 14 at 2.4 GHz(Ch1-11 for US/CA,Ch1-13 for EU/CN) WPA, WPA2, WEP, and TKIP security modes Up to +17 dBm Avg output power in 802.11b mode STA, AP, and STA+AP working modes Smart and AP network configuration modes (for Android and iOS devices) PCB On board antenna Working temperature: 20C to 85C Hangzhou Tuya Information Technology Co., Ltd. 1 V2.0.0 TCLWRQS1 Datasheet 1.2 Applications Intelligent building Smart household and home appliances Industrial wireless control Handheld device Change History No. Date Change Description Version After Change 1 2020-2-25 First release. 2.0.0 Hangzhou Tuya Information Technology Co., Ltd. 2 V2.0.0 TCLWRQS1 Datasheet Contents 1. Product Overview ............................................................................................................ 1 1.1 Features.................................................................................................................. 1 1.2 Applications ............................................................................................................ 2 2 Module Interfaces ............................................................................................................. 5 2.1 Dimensions and Footprint ...................................................................................... 5 2.2 Pin Definition .......................................................................................................... 6 2.3 Test Pin Definition ................................................................................................... 6 3 Electrical Parameters ........................................................................................................ 7 3.1 Absolute Electrical Parameters .............................................................................. 7 3.2 Electrical Conditions ............................................................................................... 7 3.3 RF Current .............................................................................................................. 8 3.5 Working Mode Current Consumptions ................................................................... 8 4 RF Features ...................................................................................................................... 9 4.1 Basic RF Features .................................................................................................. 9 4.2 Wi-Fi Output Power ................................................................................................ 9 4.3 Wi-Fi RX Sensitivity .............................................................................................. 10 5 Antenna Information ........................................................................................................ 10 5.1 Antenna Type .......................................................................................................... 10 5.2 Antenna Interference Reduction ................................................................................ 10 5.3 Antenna Connector Specifications ....................................................................... 11 6. Packaging Information and Production Instructions ...................................................... 11 6.1 Mechanical Dimensions ........................................................................................... 11 6.2 Production Instructions ......................................................................................... 11 7 MDQ and Packing Information ....................................................................................... 12 8 Appendix: Statement ....................................................................................................... 12 Hangzhou Tuya Information Technology Co., Ltd. 3 V2.0.0 TCLWRQS1 Datasheet Figures & Tables Figure 1 TCLWRQS1 front views......................................................................................... 5 Figure 2 TCLWRQS1 back views ........................................................................................ 5 Table 1 TCLWRQS1 interface pins ...................................................................................... 6 Table 2 TCLWRQS1 test pins .............................................................................................. 6 Table 3 Absolute electrical parameters ................................................................................ 7 Table 4 Normal electrical conditions .................................................................................... 7 Table 5 Current during constant transmission and transmitting .......................................... 8 Table 6 RX power consumption during constant receiving ................................................. 8 Table 8 Basic RF features.................................................................................................... 9 Table 9 TX power during constant emission ........................................................................ 9 Table 10 RX sensitivity ....................................................................................................... 10 Figure 3 TCLWRQS1 mechanical dimension .................................................................... 11 Hangzhou Tuya Information Technology Co., Ltd. 4 V2.0.0 TCLWRQS1 Datasheet 2 Module Interfaces 2.1 Dimensions and Footprint TCLWRQS1 dimensions: 49.3mm0.35mm(L)30.80.35mm(W) 7.80.15mm (H). Note :(H) is the total height of Bottom surface components and Top surface components of the transfer plate Figure 1, Figure 2 shows the TCLWRQS1 dimensions. Figure 1 TCLWRQS1 front views Figure 2 TCLWRQS1 back views Hangzhou Tuya Information Technology Co., Ltd. 5 V2.0.0 TCLWRQS1 Datasheet 2.2 Pin Definition Table 1 describes the interface pins. Table 1 TCLWRQS1 interface pins No. Symbol I/O Type Function 1 2 3 4 Vin GND TXD RXD P P I/O I/O Power supply pin 5v input Power supply reference ground pin TX port, output 5V TTL RX port, input 5V TTL Note: P indicates power-supply pins, I/O indicates input and output pins. 2.3 Test Pin Definition Table 2 describes the test pins. Table 2 TCLWRQS1 test pins No. Symbol I/O Type Function Internal 3.3V Power pin for downloading and authorizing Internal GND pin UART_Rx I/O Used for authorization UART_Tx Used for authorization 1 2 3 4 5 6 7 3.3V GND Log_Tx Log_Rx P P I/O I/O I/O
Note: Test pins cannot be used. Log TxUsed for debugging to print the log information Log RxUsed for debugging to print the log information Used for RF test Hangzhou Tuya Information Technology Co., Ltd. 6 V2.0.0 TCLWRQS1 Datasheet 3 Electrical Parameters 3.1 Absolute Electrical Parameters Table 3 Absolute electrical parameters Parameter Description Minimum Maximum Unit Value Value Storage temperature 20 Power supply voltage
Tamb = 25C N/A 85 5.5 2 Tamb = 25C N/A 0.5 Ts VBAT Static electricity voltage
(human body model) Static electricity voltage
(machine model) 3.2 Electrical Conditions Table 4 Normal electrical conditions Parameter Description Minimum Maximum Unit Value Value Typical Value Ta Working temperature 20 N/A VBAT Power supply voltage 4.5 IO negative level input
-0.3 VCC*0.25 IO positive level input VCC*0.75 VCC IO negative level output
VCC*0.1 IO positive level output VCC*0.8 IO drive current
85 5.5 VCC 12 5
VIL VIH VOL VoH Imax C V kV kV C V V V V V mA Hangzhou Tuya Information Technology Co., Ltd. 7 V2.0.0 TCLWRQS1 Datasheet 3.3 RF Current Table 5 Current during constant transmission and transmitting Working Status Parameter Mode Rate Typical Value Unit TX Power 802.11b 802.11g TX 11 Mbit/s 18.76 dBm 270 54Mbit/s 17.48 dBm 255 11n BW20/BW40 Mcs7 16.56dBm 235 mA mA mA 3.4 Wi-Fi RX Power Consumption Table 6 RX power consumption during constant receiving Symbol Mode Rate Typical Value Unit IRF IRF CPU Sleep 11 Mbit/s 90 CPU Active 54 Mbit/s 120 mA mA 3.5 Working Mode Current Consumptions Table 7. Working current consumption Mode AT TA=25 Typical Max*
Unit Module is under EZ paring mode, wifi indicator 95 245 EZ Mode AP Mode light flashes quickly light flashes slowly Module is under AP paring mode, wifi indicator 88 150 mA mA Operation Mode Module is connected, wifi indicator light is on 45 220 mA Notethe above parameters are different according to the firmware functions. Hangzhou Tuya Information Technology Co., Ltd. 8 V2.0.0 TCLWRQS1 Datasheet 4 RF Features 4.1 Basic RF Features Table 8 Basic RF features Parameter Description Frequency band 2400 GHz to 2483.5 MHz Wi-Fi standard IEEE 802.11b/g/n20 /n40(channels FCC:1-11 CE:1-13) Data transmission rate 802.11b: 1, 2, 5.5, or 11 (Mbit/s) 802.11g: 6, 9, 12, 18, 24, 36, 48, or 54 (Mbit/s) 802.11n: HT20 MCS0 to MCS7 802.11n: HT40 MCS0 to MCS7 Antenna type Onboard PCB antenna 4.2 Wi-Fi Output Power Table 9 TX power during constant emission Parameter Minimu m Value Typical Value Maxim Unit um Value Average RF output power, 802.11b CCK mode 1 N/A 18.76 N/A dBm Average RF output power, 802.11g OFDM 54 N/A 17.48 N/A dBm Mbit/s Mbit/s Average RF output power, 802.11n OFDM MCS7 N/A 16.65 N/A dBm mode mode Frequency error 20 N/A 20 ppm Hangzhou Tuya Information Technology Co., Ltd. 9 V2.0.0 TCLWRQS1 Datasheet 4.3 Wi-Fi RX Sensitivity Table 10 RX sensitivity Parameter Minimum Value Typical Value Maximum Value Unit PER < 8%, 802.11b CCK mode 1 Mbit/s N/A 90 N/A dBm PER < 10%, 802.11g OFDM mode 54 Mbit/s N/A 73 N/A dBm PER < 10%, 802.11n OFDM mode MCS7 N/A 70 N/A dBm 5 Antenna Information 5.1 Antenna Type TCLWRQS1 uses the onboard PCB antenna. 5.2 Antenna Interference Reduction To ensure optimal Wi-Fi performance when the Wi-Fi module uses an onboard PCB antenna, it is recommended that the antenna be at least 15 mm away from other metal parts. To prevent adverse impact on the antenna performance, do not use copper or route cables along the antenna area on the PCB. For details about the onboard PCB antenna area on a module, see Figure 3. Hangzhou Tuya Information Technology Co., Ltd. 10 V2.0.0 TCLWRQS1 Datasheet 5.3 Antenna Connector Specifications There is no antenna connector for this module 6. Packaging Information and Production Instructions 6.1 Mechanical Dimensions Figure 3 TCLWRQS1 mechanical dimension 6.2 Production Instructions 1. Storage conditions for a delivered module are as follows:
(1) The moisture-proof bag is placed in an environment where the temperature is below 30C and the relative humidity is lower than 70%.
(2) The shelf life of a dry-packaged product is six months from the date when the product is packaged and sealed. Attention:
(1) In the whole process of production, operators at all stations must wear electrostatic rings.If the 30% circle is pink, bake the module for 4 consecutive hours.
(2) During operation, strictly prevent water or dirt from touching the module Hangzhou Tuya Information Technology Co., Ltd. 11 V2.0.0 TCLWRQS1 Datasheet 7 MDQ and Packing Information MOQ and packing information Product Model MOQ Packing Method Number of Modules in Each Reel Pack Number of Reel Packs in Each Box TCLWRQS1 Tray 8 Appendix: Statement Federal Communications Commission (FCC) Declaration of Conformity FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This device complies with Part 15 of the FCC Rules.Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled rolled Hangzhou Tuya Information Technology Co., Ltd. 12 V2.0.0 TCLWRQS1 Datasheet environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. Important Note This radio module must not installed to co-locate and operating simultaneously with other radios in host system except in accordance with FCC multi-transmitter product procedures. Additional testing and equipment authorization may be required to operating simultaneously with other radio. The availability of some specific channels and/or operational frequency bands are country dependent and are firmware programmed at the factory to match the intended destination. The firmware setting is not accessible by the end user. The host product manufacturer is responsible for compliance to any other FCC rules that apply to the host not covered by the modular transmitter grant of certification. The final host product still requires Part 15 Subpart B compliance testing with the modular transmitter installed. The end user manual shall include all required regulatory information/warning as shown in this manual, including: This product must be installed and operated with a minimum distance of 20 cm between the radiator and user body. This device have got a FCC ID2ANDL-TCLWRQS1.The final end product must be labeled in a visible area with the following: Contains Transmitter Module FCC ID:2ANDL-TCLWRQS1 This device is intended only for OEM integrators under the following conditions:
1)The antenna must be installed such that 20cm is maintained between the antenna and users, and 2) The transmitter module may not be co-located with any other transmitter or antenna. As long as 2 conditions above are met, further transmitter test will not be required. However, the OEM integrator is still responsible for testing their end-product for any additional compliance requirements required with this module installed. Declaration of Conformity European notice Hereby, Hangzhou Tuya Information Technology Co., Ltd declares that this module product is in compliance with essential requirements and other relevant provisions of Directive 2014/53/EU,2011/65/EU.A copy of the Declaration of conformity can be found at https://www.tuya.com Hereby, Hangzhou Tuya Information Technology Co., Ltd declares that this module product is in compliance with essential requirements and other relevant provisions of Directive 2014/53/EU,2011/65/EU.A copy of the Declaration of conformity can be found at https://www.tuya.com Hangzhou Tuya Information Technology Co., Ltd. 13 V2.0.0 TCLWRQS1 Datasheet This product must not be disposed of as normal household waste, in accordance with EU directive for waste electrical and electronic equipment (WEEE- 2012/19/EU). Insteadit should be disposed of by returning it to the point of sale, or to a municipal recycling collection point. Hangzhou Tuya Information Technology Co., Ltd. 14 V2.0.0