all | frequencies |
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|
manual | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User Manual | Users Manual | 2.18 MiB | February 08 2023 / February 27 2023 | |||
1 |
|
Internal Photos | Internal Photos | 1.65 MiB | February 08 2023 / February 27 2023 | |||
1 |
|
External Photos | External Photos | 1.06 MiB | February 08 2023 / February 27 2023 | |||
1 |
|
Label and location | ID Label/Location Info | 51.91 KiB | February 08 2023 / February 27 2023 | |||
1 |
|
Antenna Information | Operational Description | 181.81 KiB | February 08 2023 / February 27 2023 | |||
1 | Bill of Materials | Operational Description | February 08 2023 | confidential | ||||
1 |
|
Cover Letter | Cover Letter(s) | 109.00 KiB | February 08 2023 / February 27 2023 | |||
1 |
|
FCC Attestation Statement | Attestation Statements | 25.04 KiB | February 27 2023 | |||
1 |
|
FCC ISED Agent Authorisation Letter | Cover Letter(s) | 56.07 KiB | February 08 2023 / February 27 2023 | |||
1 |
|
FCC Request for Confidentiality | Cover Letter(s) | 34.38 KiB | February 08 2023 / February 27 2023 | |||
1 |
|
FCC US Agent Attestation | Attestation Statements | 167.81 KiB | February 27 2023 | |||
1 | Frequency Block Diagram | Block Diagram | February 08 2023 | confidential | ||||
1 | Operational Description | Operational Description | February 08 2023 | confidential | ||||
1 |
|
RF Exposure Report | RF Exposure Info | 340.39 KiB | February 08 2023 / February 27 2023 | |||
1 | Schematics | Schematics | February 08 2023 | confidential | ||||
1 |
|
Test Report | Test Report | 1.09 MiB | February 08 2023 / February 27 2023 | |||
1 |
|
Test Setup Photos | Test Setup Photos | 2.14 MiB | February 08 2023 / February 27 2023 |
1 | User Manual | Users Manual | 2.18 MiB | February 08 2023 / February 27 2023 |
WE GENERATE SOLUTIONS RFID Englisch Customer manual LFM 32x WipRack Rev1.1 HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 4x Reader Rev1.3 back to the table of contents www.hermos.com 1 Customer Manual LFM 32x WipRack RFID WE GENERATE SOLUTIONS 0. Table of contents Inhaltsverzeichnis 0. Table of contents .................................................................................................................................. 2 1 . I n t r o d u c t i o n ............................................................................................................................... 5 1.1 Using the device 6 2. Version history ...................................................................................................................................... 7 3. Used abbreviations and designations ................................................................................................... 7 4. General instructions .............................................................................................................................. 8 4.1 Objective of the product manual 4.2 Warranty and liability 8 8 5. Safety instructions and warnings .......................................................................................................... 9 5.1 Scope and symbols 5.2 Safety symbols - according to DIN 4844-2 5.2.1 Mandatory signs 5.2.2 Warning signs 5.2.3 Prohibition signs 5.2.4 Other signs 5.3 Obligations 5.3.1 Operators obligations 5.3.2 Responsibilities of operating personnel 5.3.3 ESD Instructions 5.4 Residual risks 5.5 Supplemental instructions 5.5.1 Regulations and certifications 9 9 10 10 10 11 11 11 12 12 13 14 14 6. Functional description ......................................................................................................................... 15 6.1 General information 6.2 Basic functions - operating modes 6.2.1 Normal operation 6.2.2 Sensor-triggered operation 6.2.3 Test module 6.3.1 Top view 6.4 Technical Specification 6.4.1 Device labels 6.4.2 Device Label FCC ID 2AP5OLFM-32X 15 15 15 16 16 17 19 20 20 7. Installation ........................................................................................................................................... 21 7.1 Safety instructions 7.2 Qualified installation personnel 7.3 Unpacking 21 22 22 HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.1 back to the table of contents www.hermos.com 2 WE GENERATE SOLUTIONS 7.4 Mounting the device 7.5 Installing the Readhead 7.5.1 Readhead connections 7.6 Power Supply 7.7 DIP-switch 7.8 USB connection Customer Manual LFM 32x WipRack RFID 23 27 27 28 29 29 8.Commissioning .................................................................................................................................... 31 8.1 Operating conditions 8.2 The USB connector (serial interface) parameters 8.3 Parameter of the ethernet interface 8.3.1 Change networksettings with DeviceDiscoverer 8.3.2 Firmware update with DeviceDiscoverer 8.3.3 Test Device with DeviceDiscoverer 31 31 32 32 35 36 9. Operating ............................................................................................................................................ 38 9.1 Operating personnel 9.2 Protocol change 9.2.1 General 9.2.2 Automatic protocol detection 9.3 Addressing the antenna port 9.4 Customer Factoryparametersets 38 38 38 38 39 39 10. ASCI-I1 Communication protocol ..................................................................................................... 41 10.1 Structure of the communication protocol 10.2 Packet content Packet header Message data Packet end 10.3 Data elements 10.4 Protocol Commands 10.4.1 X - Read data 10.4.2 R Automatic read 10.4.3 W - Write data 10.4.4 G Query parameter 10.4.5 F Query parameter 10.4.6 P Set parameter 10.4.7 N Reset 10.4.8 e Error message 10.4.9 E Error message 10.4.10 H Heartbeat HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com 41 41 41 42 42 44 52 54 55 57 58 59 60 61 62 62 63 LFM 32x WipRack Rev1.1 back to the table of contents www.hermos.com 3 64 65 66 67 68 69 70 71 72 73 73 75 76 80 84 86 86 89 90 Customer Manual LFM 32x WipRack RFID WE GENERATE SOLUTIONS 10.4.11 V Query software version 10.4.12 L - Lock data area 10.4.13 I Adjust RF module 10.4.14 J RF module Queries the vote 10.4.15 A Sensor event object removed 10.4.16 B Sensor event object detected 10.4.17 O Set output 10.4.18 Q Querying the status of the inputs and outputs 10.4.19 D Write to Display 10.5 Parameter 10.5.1 Parameters ASC-I1 Mode 10.5.2 Additional Parameters ASC-W1 Mode 10.5.3 Additional Parameters 10.6 Message examples 10.7 Error Codes 10.8 Wiring of the outputs 10.8.1 ASC-W1 Mode: Reader in operation mode and sensor triggered reading 10.8.2 ASC-W1-Mode: Reader in operation mode and external triggered reading 10.9 ASCII table 11. Service and Troubleshooting ..................................................................................................... 93 11.1 General information 11.2 Troubleshooting personnel 11.3 Safety instructions 11.4 Error indications on the device 11.5 No communication with the reading device 11.6 Software releases 11.7 Customer service 93 93 94 95 95 96 97 12. Disassembly and storage .......................................................................................................... 98 12.1 Disassembly 12.2 Storage 98 98 13. Transport and disposal .......................................................................................................... 98 13.1 Transport 13.2 Disposal 98 98 HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.1 back to the table of contents www.hermos.com 4 WE GENERATE SOLUTIONS 1 . I n t r o d u c t i o n Customer Manual LFM 32x WipRack RFID These operating instructions are intended for the operator who must pass these on to the personnel responsible for installation, connection, use, and repairs of the machine. The operator must ensure that the information contained in these operating instructions and in the accompanying documents has been read and understood. The operating instructions must be kept at a known place that is easy to reach, and they must be consulted if there is the slightest doubt. The manufacturer assumes no responsibility for damage to persons, animals, or objects or to the unit itself arising from the improper use or the disregard or insufficient consideration to the safety criteria contained in these operating instructions or based on modifications of the unit or the use of unsuitable replacement parts. The copyright for the operating instructions lies solely with HERMOS AG Track & Trace - RFID Division Gartenstr. 19 95490 Mistelgau or its legal successor. Reproduction or circulation of this document to third parties only by express written permission of copyright holder. This also applies if only excerpts of the document are copied or circulated. These same conditions apply to the disclosure of the document in digital format. As of: July - 2018 HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.1 back to the table of contents www.hermos.com 5 WE GENERATE SOLUTIONS 1.1 Using the device Customer Manual LFM 32x WipRack RFID The device is exclusively used to read and write passive LF transponders. Any other use of the machine or any use beyond its intended purpose is considered non-intended and thus improper. In this case, the device safety and the device protection provided may be compromised. HERMOS AG is not liable for damages resulting from such use. The device was developed for the use in an industrial environment as a built-in device in other systems. It was not developed as a stand-alone or mobile device in a non-industrial environment, such as domestic, vehicle or open air use. Intended use also includes the following:
Following all the operating instructions Following all the safety instructions Improper use, which can endanger the unit, the user and third parties, include:
The use of the device contrary to its intended use Changes to the device as well as attachments and conversions Operating the unit when there are obvious problems WARNING Danger of injury due to unauthorised modifications There are risks from unauthorised modifications on the device. Only original spare parts from the manufacturer must be used. No modification, attachment or conversion may be performed on the device without the permission of HERMOS AG. WARNING Danger of injury and interruption of operation due to improper use There are risks through the improper use of the device. The device must only be used according to its intended use. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.1 back to the table of contents www.hermos.com 6 WE GENERATE SOLUTIONS 2. Version history Customer Manual LFM 32x WipRack RFID Version Date Author Amendments 1.1 15.11.2022 HERMOS AG, RK, LD, AL Documentation for LFM32x WipRack using ASCII protocol 3. Used abbreviations and designations RFID LF SEMI SECS HSMS PoE DHCP Radio Frequency Identification Low Frequency 134,2 kHz Semiconductor Equipment and Materials SEMI Equipment Communications Standard High-Speed SECS Message Service Power over Ethernet Dynamic Host Configuration Protocol HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.1 back to the table of contents www.hermos.com 7 WE GENERATE SOLUTIONS 4. General instructions Customer Manual LFM 32x WipRack RFID All previous versions of this document lose their validity with the issue of this version. We compiled the information in this document according to the best of our ability. HERMOS AG does not guarantee the accuracy and completeness of the information provided in this document and is also not liable for consequential damages based on faulty or incomplete information. 4.1 Objective of the product manual The product manual serves as support and contains all the necessary information that must be followed for general safety, transport, installation and operation. The product manual with all safety instructions (as well as all additional documents) must be:
Followed, read, and understood by all persons working with the unit (especially knowledge of the safety instructions) Easily available always to all persons Consulted if even the slightest doubt arises (safety) Objectives:
Prevent accidents Increase the service life and reliability of the unit Reduce the costs of production downtime 4.2 Warranty and liability The General Terms and Conditions of Sale and Delivery of HERMOS AG shall apply. The warranty period is 24 months beginning with the delivery of the device, which is verified by the invoice or other documents. The warranty includes repairs of all damages to the unit that occur during the warranty period and were clearly caused by material or manufacturing defects. Warranty and liability claim in the event of personal injury or property damage are excluded if they arise from one or more of the following causes:
Improper use of the unit Disregarding the information in the operating instructions Unauthorised structural modifications of the unit Insufficient maintenance and repairs Disaster events due to impact with foreign objects or force majeure HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.1 back to the table of contents www.hermos.com 8 WE GENERATE SOLUTIONS Customer Manual LFM 32x WipRack RFID 5. Safety instructions and warnings 5.1 Scope and symbols Follow the general safety instructions as well as special safety instructions included in the chapters. The unit was built according to state-of-the-art technology and recognised safety regulations. In order to prevent danger to life and limb of the user, third parties, or the unit, only use the unit for its intended purpose and in perfect condition with regard to safety. Bodily injuries and/or property damages resulting from non-compliance with the instructions provided in the operating instructions are the responsibility of the company operating the unit or the assigned personnel. Faults that may compromise safety must be eliminated immediately. DANGER Risk of death, injury and property damage. There is a risk of danger due to disregard of the product manual and the safety information contained therein. Read the product manual carefully before putting the unit into operation for the first time. Fulfil all required safety conditions. 5.2 Safety symbols - according to DIN 4844-2 The following special safety symbols in accordance with DIN 4844-2 are used at the corresponding passages in the text of this product manual and require special attention depending on the combi- nation of the signal word and symbol. DANGER Risk of injury due to disregarding the safety symbols. Risks exist when disregarding warnings in the operating instructions. Follow all warnings. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.1 back to the table of contents www.hermos.com 9 WE GENERATE SOLUTIONS 5.2.1 Mandatory signs Customer Manual LFM 32x WipRack RFID Observe additional information Use safety goggles Wear ear protection Wear safety shoes Important note 5.2.2 Warning signs Warning of a hazardous area Warning of hazardous electrical voltage Warning of electromagnetic radiation Warning of flammable substances Warning of explosive substances Warning of electrostatically sensitive components 5.2.3 Prohibition signs Unauthorised access is prohibited Fire, open flame and smoking prohibited Switching prohibited Prohibited HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.1 back to the table of contents www.hermos.com 10 WE GENERATE SOLUTIONS 5.2.4 Other signs Customer Manual LFM 32x WipRack RFID Verpackungsmaterial vor-
schriftsgem entsorgen Recycling 5.3 Obligations 5.3.1 Operators obligations A safe condition and use of the unit is a requirement for a safe operation of the unit. For that rea-
son, the operator has the obligation to ensure that the following points are adhered to:
The unit may only be operated by trained and authorised personnel. Prohibit unsafe or dangerous working methods! If necessary, check the conduct and actions of its personnel!
Have personnel who must be trained, instructed or within the scope of general training work only on the unit under the supervision of an experienced person!
Have the personnel confirm by their signature that the operating instructions have been understood!
Precisely establish responsibilities according to the various task areas (operation, installation)!
Operating personnel must be required to immediately report any occurring and identifiable safety deficiencies to their superior!
HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.1 back to the table of contents www.hermos.com 11 WE GENERATE SOLUTIONS Customer Manual LFM 32x WipRack RFID 5.3.2 Responsibilities of operating personnel The operating personnel are obligated to contribute to the prevention of work accidents and their consequences by their personal conduct. WARNING 5.3.3 ESD Instructions CAUTION Risk of injury due to insufficient personnel qualifications There are dangers to personnel and the proper operation due to inadequately qualified personnel. Only trained personnel may operate the unit. New operating personnel must be instructed by the existing operating personnel. The operator must precisely regulate the personnels areas of responsibility, competence, and monitoring precisely. The personnel for the areas of responsibility mentioned above must have the corresponding qualification for this work (training, instruction). If necessary, this can be done by the manufacturer on behalf of the operator. In case of disregard, all warranty claims are void. Static electricity can damage electronic components in the unit. All persons who install or maintain the unit must be trained in ESD protection. ESD protective measures must be applied when opening the unit. Disconnect the power supply prior to removing or adding components!
Observe the basic principles of ESD protection Take the appropriate ESD precautionary measures HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.1 back to the table of contents www.hermos.com 12 WE GENERATE SOLUTIONS 5.4 Residual risks Customer Manual LFM 32x WipRack RFID Despite all precautionary measures taken, there may still be residual risks that are not apparent. Adhering to the safety instructions, the intended use, and the product manual as a whole can re- duce residual risks. DANGER ATTENTION Danger caused by electrical current Electrical residual energy remains in lines, equipment and devices after shutting down the device. Only qualified electricians may perform work on the electrical supply system. Disconnect the unit from the power supply system if active parts of the unit can be accessed using tools. Access is only permitted by authorised personnel. Regularly check the electrical equipment of the unit. Regularly check all moving cables for damage within the scope of maintenance and repair work. DANGER Dangers of fire and explosion There is a risk of fire and explosions in the vicinity of the device. Smoking, exposed flames and fire are strictly prohibited in the vicinity of the unit. Do not store any flammable liquids within the hazardous area of the device. A fire extinguisher must be kept in the vicinity of the device. WARNING Warning of electromagnetic radiation Electromagnetic radiation develops when transmitting and receiving data. Arrange the antenna in such a position that it is not in the vicinity or make contact with the human body while transmitting. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.1 back to the table of contents www.hermos.com 13 WE GENERATE SOLUTIONS 5.5 Supplemental instructions Customer Manual LFM 32x WipRack RFID Read and understand all safety and operating instructions prior to installing and operating the device. This documentation was written for specifically trained personnel. The installation, operation and error handling may only be carried out by specifically trained personnel. Keep these instructions. Keep this documentation in a location that is accessible to all personnel involved with the installation, use, and error handling of the device. Follow all warnings. Follow all warnings on and in the device and in the documentation. Install the unit only in accordance with the manufacturers instructions. Use only the accessories and cables from the manufacturer. Troubleshooting that is not described in the chapter a service and troubleshooting may only be performed by the manufacturer. When connecting cable connections, only pull on the plug and not on the cable. Only use spare parts specified by the manufacturer. The provisions of the accident-prevention regulations of the government safety organisations always apply to all work on the unit. Applicable, legally binding accident prevention regulations. Applicable binding regulations at the place of use Technical standards for safety and professional work Existing environmental protection regulations Other applicable regulations 5.5.1 Regulations and certifications The electrical design and documentation satisfy the DIN / VDE, EN / IEC regulations. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.1 back to the table of contents www.hermos.com 14 Customer Manual LFM 32x WipRack RFID WE GENERATE SOLUTIONS 6. Functional description 6.1 General information LF reading devices are radio frequency identification systems that use radio transmission to read or write data of LF transponders (134,2 kHz), which operate as tamper-proof electronic tags. The LF reading devices communicate with common transponders (134,2kHz) according to ISO 18000-2 and ISO 11785 that are available on the market. The data is transmitted via the existing interface with the present transmission parameters. If several interfaces are available and connected to the host, the transmission is always carried out on the most recently used interface. The data is embedded in a defined communication protocol and exchanged between the reader and host. 6.2 Basic functions - operating modes During normal operation, the LF reading device supports various basic functions:
Heartbeat function, software version query Scanning of transponders in the antenna area (UID) Reading data Writing data Locking data Setting and reading out parameters Setting and querying inputs and outputs The LF devices can be set in 3 other operating modes by setting the parameters: Polling operation
(optional), sensor-triggered automatic reading and test mode. 6.2.1 Normal operation During normal operation, the LF reading device is immediately ready for operation after a reset. It does not perform any automatic actions in this mode (standby). During normal operation, actions are triggered by protocol commands from the host. A scanning procedure or reading in the data area is initiated by a command of the host system using the communication protocol. In addition to the actions triggered by the host, a corresponding message can be automatically sent to the host and an automatic reading operation can be started by activating or releasing a sensor. When the reading operation is successful, the read data is immediately transmitted to the host. If several antenna ports are occupied simultaneously, the reading operations are processed sequentially. Writing actions (data saved to a transponder) are generally only possible via commands from the host. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.1 back to the table of contents www.hermos.com 15 WE GENERATE SOLUTIONS Customer Manual LFM 32x WipRack RFID 6.2.2 Sensor-triggered operation Device versions with IO module (at least 1 input) offer the function of a sensor-triggered automatic reading operation. The reading device automatically performs a reading operation when the input is triggered. The type of action (inventory/reading) can be defined with the parameters Read mode and Read page. The read data is automatically sent to the host. The result of the reading operation (successful, not successful) can be optionally output via I/O s of the respective antenna port. 6.2.3 Test module The HERMOS LF reading devices support a test mode that facilitates setting up the antenna and checking the reading ranges during commissioning. From the 4 Dip-Switches (near the network connector) the DIP3 and DIP4 are used for test mode. The evaluation of the DIP switch depends on parameters. See also chapter DIP-switch. If the device is in read test mode, the reader triggers every 300ms a read at the last selected I/O port. For detected sensor:
If no transponder could be read the red port LED is short switched on for 200ms. As long as a tag is read successfully, the green port LED is on. For released sensor:
If no transponder could be read the red port LED is short switched on for 20ms. As long as a tag is read successfully, the green port LED is flashing with about 2,5Hz (200ms on/off). For the write testmode at first a tag read is triggered every 300ms. When the tag could be read than the reader triggers a tag write every 500ms. When tag write fails than the tag read is triggered again every 300ms. For the write testmode a yellow port LED (red and green port LED switched on) indicates that the tag could only read. The green port LED indicates the success of read and write process. During test mode, the green status LED flashes if the read or write fails and lights up steadily if the read or write succeeds. The orange status LED has no functionality and is permanently switched on. See also Status LEDs. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.1 back to the table of contents www.hermos.com 16 Customer Manual LFM 32x WipRack RFID WE GENERATE SOLUTIONS 6.3 Illustration 6.3.1 Top view Component Description 24VDC Two-pin socket for the connection of the 24V DC power supply. Power-LED The green power LED indicates that the operating voltage is present and the device is ready for operation. Status-LEDs The two status LEDs are used for the reading and writing feedback in test mode. If the device is in test mode, the green status LED flashes if the read or write fails and lights up steadily if the read or write succeeds. During test mode the orange status LED has no functionality and is permanently switched on. After a restart, a short self-test of the LEDs, then display of the protocol:
SECS: The green LED goes on briefly ASCII: The yellow LED goes on briefly See chapter Dip-switch for functionality. The device features an Ethernet interface. The communication with the device can be carried out via the 10/100 BaseT interface. The Ethernet interface is generally PoE capable. DIP-switch LAN/POE HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.1 back to the table of contents www.hermos.com 17 WE GENERATE SOLUTIONS Customer Manual LFM 32x WipRack RFID USB interface Interface for Service See chapter USB-connection. Antenna Port 1-32 IO Port 1-32 SMB connections for connecting the up to 32 antennas RJ12 connection for the up to 32 Readhead In-/Outputs Pin assignment Readhead LED 2 at Readhead green LED LED 1 at Readhead red LED at Readhead LED 1 and LED 2 toghether on appers as yellow LED HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.1 back to the table of contents www.hermos.com 18 WE GENERATE SOLUTIONS 6.4 Technical Specification Technical data Voltage (protected against reverse polarity) Power consumption
(passive, reading, pulse) Customer Manual LFM 32x WipRack RFID 20 28 V DC, or PoE 60mA, 200mA, max.300mA (@24VDC) Fuse type Nano2 Operating temperature 375 mA
-0 to 50 C Storage temperature
-20 C to 70 C Permissible humidity at 50C 25 80 %
Transmission frequency 134,2 kHz Ethernet interface 10/100 BaseT, (PoE, IEEE 802.3af) Protocol Housing material Protection ASCII PVC IP40 Reader dimensions 335 x 140 x 45 mm Weight approx. 900 g HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.1 back to the table of contents www.hermos.com 19 WE GENERATE SOLUTIONS 6.4.1 Device labels Customer Manual LFM 32x WipRack RFID The device label is located on the reading unit housing. It contains a CE mark, article/serial number and the MAC address. 1. Designation 2. Article number (variants) 3. Serial number (example) 4. MAC address 5. Manufacturer 6.4.2 Device Label FCC ID 2AP5OLFM-32X FCC
- The Federal Communications Commission (FCC) warns the users that changes or modifications to the unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. RF exposure statement (mobile and fixed devices) This device complies with the RF exposure requirements for mobile and fixed devices. However, the device shall be used in such a manner that the potential for human contact during normal operation is minimized.
- FCC 15.105 (a):
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.1 back to the table of contents www.hermos.com 20 WE GENERATE SOLUTIONS 7. Installation Customer Manual LFM 32x WipRack RFID Follow the basic safety instructions in the chapter Safety instructions. 7.1 Safety instructions The unit is exclusively designed for indoor use in an industrial environment. The unit may only be installed indoors with a temperature and humidity level with in the range of the specified technical module parameters. Never use the unit near or in water. Never pour liquids of any type over the unit. However, if the unit should still come in contact with liquid, disconnect it and have it checked by a technician. Do not install the device near heat sources such as radiators, heat registers, stoves or other devices (including amplifiers) that generate heat. Do not install the unit in a flammable environment. Never expose the device to extreme temperature fluctuations, since condensation otherwise develops inside the unit and causes damages. Do not install the device in the vicinity of voltage lines or other power lines with which they could collide (for example, drilling), which could result in serious injuries or even death. The device (especially the antenna) should not be installed in the immediate vicinity of electrical equipment such as medical devices, monitors, telephones, TV sets and magnetic disks, and metal objects. This could result in reduced read and write ranges. Never use the unit in explosive areas (such as paint warehouses). Do not use the device in areas where it is exposed to vibrations or shocks. The installation location must be adequately illuminated during the installation. Never install the unit during a lightning storm. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.1 back to the table of contents www.hermos.com 21 WE GENERATE SOLUTIONS Customer Manual LFM 32x WipRack RFID Make sure that the installation meets the requirements of the FCC
(country specific) for human exposure to radio frequencies. 7.2 Qualified installation personnel The unit must only be installed by specially trained personnel. If you have any doubts about the qualifications, please contact the manufacturer. If the unit is operated by untrained personnel, the reading device and or connected devices may be damaged. 7.3 Unpacking The LF reading device and the accessories can be packed customer-dependent in clean room conditions. In order to maintain this condition, the devices must be unpacked in clean room conditions. The packaging material consists of cardboard and foil. Dispose of these materials separately under the respective regulations of your country. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.1 back to the table of contents www.hermos.com 22 WE GENERATE SOLUTIONS 7.4 Mounting the device Customer Manual LFM 32x WipRack RFID The mounting surface must be stable, non-flammable, dry and clean. If necessary, clean it before you install the device. Only mount the components on mounting-rail TS 35, at the designated locations and make sure that the operating and ambient conditions specified in the technical data are always maintained. Dimensions:
HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.1 back to the table of contents www.hermos.com 23 WE GENERATE SOLUTIONS 7.5 Installing the Readhead Customer manual LFM 32x WipRack RFID The Readhead housing is optimized for grid-shelves mounting. 7.5.1 Readhead connections Antenna: SMB IOs: RJ12 HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 27 WE GENERATE SOLUTIONS Customer manual LFM 32x WipRack RFID Use the antennas and antenna cable from the manufacturer to ensure optimum reading and writing ranges. 7.6 Power Supply The device can be connected to an external power supply (24VDC, 0.5A) or power up with POE. There are risks if the device is supplied with the incorrect voltage. Only use cables, plugs and adapters from the manufacturer. Observe power ratings provided in the technical data. Never connect the reading device to an external power supply and a PoE cable at the same time. This can damage the reading device or the connected components. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 28 WE GENERATE SOLUTIONS Customer manual LFM 32x WipRack RFID 7.7 DIP-switch Test mode can be activated via the 4 DIP switches on the device. In test mode, a continuous reading operation is performed at the set antenna port and the result of the reading operation is displayed on the green status LED. The test mode is activated by setting DIP switch 3 to ON. DIP switch 4 can be used to select between test reading and test writing. For the LFM32x WipRack reader the selection of the antenna port is changed by a change of detected port sensor. Switch Function 1 2 3 4 No function No function off: Operation mode on: Activated test mode DIP 3 off: Deactivated test mode off->on Start Antenna Tuning DIP 3 on: Activated test mode Selection of the test function:
off = Read, on = Write 7.8 USB connection The LFM 32x WipRack reader has an additional serial interface that is designed as a USB service interface (USB micro socket!) and can be connected to any USB port of a running PC. We recommend using a high-quality USB cable with a USB micro connector and a maximum length of 3m to ensure secure communication. Before connecting the reader, however, the driver for the virtual COM port must be successfully installed so that the connected device can be addressed via the virtual COM port. The driver is available in the download area of the RFID products on the HERMOS homepage:
Homepage:
Benutzername:
Passwort:
http://www.hermos.com/en/protected Customer_LF 781692 HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 29 WE GENERATE SOLUTIONS Customer manual LFM 32x WipRack RFID After downloading and unpacking the driver, the installation is started by running the CP210xVCPInstaller_x64.exe or CP210xVCPInstaller_x86.exe application. When using a single USB reader, select the "SingleReader" driver. The reader can be operated on any USB port of the PC. When using several USB readers at the same time, select the "MultiReader" driver. A virtual serial interface is assigned to each USB port. A reader can be installed on each USB port of the PC. The USB reader is now plugged into a USB port of the PC, the computer recognizes the device and automatically starts the driver installation. Follow the further installation instructions and install the software via "Install the software automatically". If the automatic installation fails, start the manual installation. If the driver is successfully installed and the USB reader is plugged in, it can be addressed via the virtual COM port. The associated virtual COM port is displayed as
"Silicon Labs USB to UART Bridge" in the device manager of the control panel. The parameters of the serial interface can be found in Chapter 8. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 30 Customer manual LFM 32x WipRack RFID WE GENERATE SOLUTIONS 8.Commissioning 8.1 Operating conditions The following requirements must be fulfilled for smooth device operation. 1. 2. 3. 4. 5. The operating temperature must be within the scope of the values specified in the technical data. The device must be connected to the power supply (provide PoE is not used). An antenna must be properly connected to the reading device. A transponder must be within the reading and writing ranges of the connected antenna. For normal operation, deactivate test mode after installation. (All DIP switches off). 8.2 The USB connector (serial interface) parameters The following serial interface settings (USB connector) are set upon delivery. The baud rate can be set via parameters. Baudrate Databits Stopbits Parity Wert 19200 8 1 Even The USB service interface (virtual COM port !) can be used to parameterise, test and load the firmware with the Hemos DeviceDiscoverer, the respective reader. If you want to communicate with the device via the serial interface, you can switch to serial communication via the "RS232" tab.
- With the "Open" button (arrow 1) the selected COM port can be opened with the selected settings. Serial communication then takes place with the selected settings and the responding reader is entered in the device list. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 31 WE GENERATE SOLUTIONS Customer manual LFM 32x WipRack RFID
- A reader search with several typical port settings is carried out one after the other via the
"Start Search" button (arrow 2) via the selected COM port. The search begins with the currently set values for baud rate and parity. If serial communication is established, the further search is aborted, the determined settings for baud rate and parity are accepted and the reader is entered in the device list. 8.3 Parameter of the ethernet interface The unit is connected to the customer network via a 10/100BaseT Ethernet interface. The DHCP (Dynamic Host Configuration Protocol) is activated on delivery. If there is not a DHCP server available in your network, a random IP address is set from the Zero- Conf range (169.254.0.0/16) and operations must still be performed to obtain an IP address. If an IP address could be obtained or with a static IP address, the device can be connected via TCP / IP port 3241 in the delivery state. The HERMOS DeviceDiscoverer is available for configuring the network setting. 8.3.1 Change networksettings with DeviceDiscoverer HERMOS components can be found in the LAN network and settings can be easily changed using the DeviceDiscoverer. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 32 WE GENERATE SOLUTIONS Customer manual LFM 32x WipRack RFID HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 33 WE GENERATE SOLUTIONS Customer manual LFM 32x WipRack RFID 1. 2. 3. Select your network interface if you have several options on your PC. Your network is automatically scanned for all HERMOS reading devices using the Search Devices button. Select the desired reading device in the list to open the network settings. Here, you can edit the network settings and apply them to the reading device by pressing the respective button. Use HERMOS if you are asked to enter a password!
After parameters are changed, the reading device reboots and can be read in using Search Devices. CAUTION Changing network settings generally cause the reading device to reboot. This closes an existing HSMS host connection. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 34 WE GENERATE SOLUTIONS Customer manual LFM 32x WipRack RFID 8.3.2 Firmware update with DeviceDiscoverer Firmware updates can also be performed using the HERMOS DeviceDiscoverer. Start the tool with administrator rights and scan the network for all HERMOS devices. To do an update, mark the desired reading device and select Firware Update. Use HERMOS if you are asked to enter a password!
1. 2. 3. 4. Click the "Firmware Update" button to open the new Firmware Download window for the selected reader. It is usually not necessary to open the download connection as this happens automatically. Otherwise, pressing the Connect button will open the download connection. Select the new firmware file using the load image button. Start the download process. Wait until the Download Finished message appears. CAUTION During the download process, do not disconnect the power supply or interrupt the network connection. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 35 WE GENERATE SOLUTIONS 8.3.3 Test Device with DeviceDiscoverer Customer manual LFM 32x WipRack RFID Readers can also be tested with the HERMOS "Device Discoverer" if you have one support feature. Start the tool with administrator rights and search for the HERMOS device under test in the network. Select the desired reader and select the "Device Test" button independently of your interface. A further "Device Test" view is opened with which the addressed reader can be tested via the UDP protocol without having to disconnect any existing TCP / IP connection. Expert Mode:
In the "Expert Mode" tab you can select from a list of test commands and send this after any modification. The Trace window below shows all traffic generated when testing with UDP. The success code of the response message is displayed in the status bar at the bottom left. The tab register mode is a feature only for experts!
HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 36 WE GENERATE SOLUTIONS Customer manual LFM 32x WipRack RFID Parameters:
In the "Parameters" tab you can choose from a list of parameters that can be read and written. CAUTION When setting and reading parameters, it must be carefully considered which communication protocol is currently set. Some parameters are defined differently in different protocols. LF Module:
In the register "LF Module" a test reading can be carried out. One or more pages of a multipage transponder can be read out. The success code of the triggered reading is displayed in the status bar at the bottom of the window. Via a scan, the first page of every readable 134.2 kHz LF transponder is read out and displayed. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 37 Customer manual LFM 32x WipRack RFID WE GENERATE SOLUTIONS 9. Operating 9.1 Operating personnel The device should only be operated by specially trained personnel. If you have any doubts about the required qualifications, please contact the manufacturer. The operation of the device without special expertise can result in damages to the device or on connected devices. 9.2 Protocol change 9.2.1 General To communicate with a connected host system, some reader supports ASCII or SECS /
HSMS protocols. The protocol selection takes place by means of automatic protocol recognition. The currently set protocol is displayed on the status LED during the boot process. SECS: The red LED goes on briefly after self test ASCII: The yellow LED goes on several times Since the LFM 32x WipRack reader only supports the ASCII protocol, automatic protocol recognition is deactivated. 9.2.2 Automatic protocol detection The reader automatically adjusts to the protocol used by checking and evaluating the first message after a reset. The interface is changed accordingly when the protocol is changed and reinitiali- zed. This process can take several seconds. Already sent messages are lost. The newly recognized protocol is used for further communication. A renewed change is only possible after another reset. Automatic protocol detection can be enabled or disabled by setting parameter 98 (0x62). With automatic protocol detection enabled, receiving undefined or random characters may result in an accidental protocol change. Since the LFM 32x WipRack Reader only supports ASCII protocol, automatic protocol detection is disabled and it is not recommended to enable this feature!
HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 38 WE GENERATE SOLUTIONS 9.3 Addressing the antenna port Customer manual LFM 32x WipRack RFID The LFM 32x WipRack reader is equipped with 32 antenna ports. Each of these ports has its own antenna tuning with which the connected antenna is tuned to the ambient conditions. In the set protocol, the read or write commands are always executed by port. The 32 antenna ports from 1 to 32 are numbered consecutively and are addressed accordingly in the logging command. In the ASCII protocol, the reader ID decides on the selection of the antenna port. The reader ID (00 to 1F) responds to the respective antenna port 1 to 32. 9.4 Customer Factoryparametersets The reader LFM 32x WipRack can be delivered with a few Factoryparametersets. The settings of the Factoryparameterset is part of the factory settings and should only be changed by Hermos. If customer needs another Factoryparameterset setting, please ask Hermos for the necessary steps. The installed Factoryparameterset can be read by parameter 64 (use command G0164). Factoryparameterset 3: (CFP3 ASC-W1 mode) The reader only distributes the advanced SZ ASCII protocol, where up to 32 antenna ports can be addressed by a 2 ASCII characters port ID 00 up to1F. The antenna is addressed by the ReaderID 00 to 1F, or TargetID 01 to 32. If SECS protocol could be used, then no MID area would be defined. The USB connector (virtual COM-Port) can be used for serial host communication. For the TCP/IP communication the complete end packet of the ASCI-I1 protocol will be transmitted (end character and 4 bytes checksum). P-command: The parameter value will be interpreted as hexadecimal value. The additional F-command can be used to deliver the parameter value with hexadecimal interpretation. X/R/W-command: The page value will be interpreted as hexadecimal value. Errors will be send with the command E. With default settings a confirmation has to be send. The additional B-command can be used for signal the detection of an object. On default the master/slave mode is deactivated, so the Ethernet port and the USB port can be used for host communication. On default the ports LEDs are not influenced by sensor triggered events. Factoryparameterset 4: (CFP4 standard ASC-I1 mode with watchport 0 to 3) The reader only distributes the advanced SZ ASCII protocol, where up to 32 antenna ports can be addressed by a 2 ASCII characters port ID 00 up to1F. The antenna will be addressed by the ReaderID 00 to 1F or TargetID 01 to 32. If SECS protocol could be used, then the standard MID range of 2 pages / 16 characters would be defined. The additional B-command can be used for signal the detection of an object. The RS232 port can be used for serial host communication. On default the ports LEDs are not influenced by sensor triggered events. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 39 WE GENERATE SOLUTIONS Customer manual LFM 32x WipRack RFID Factoryparameterset 6: (CFP6 standard ASC-I1 mode with watchport 0 to 1) The reader only distributes the advanced SZ ASCII protocol, where up to 32 antenna ports can be addressed by a 2 ASCII characters port ID 00 up to1F. The antenna will be addressed by the ReaderID 00 to 1F or TargetID 01 to 32. If SECS protocol could be used, then the standard MID range of 2 pages / 16 characters would be defined. On default the additional B-command can not be used for signal the detection of an object. On parameter reading with Gxy (xy:= readerID) only the parameter 0 up to 7 will be send. The RS232 port can be used for serial host communication. On default the ports LEDs are not influenced by sensor triggered events. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 40 WE GENERATE SOLUTIONS Customer manual LFM 32x WipRack RFID 10. ASCI-I1 Communication protocol 10.1 Structure of the communication protocol The communication is carried out via ASCII packets. After each command to the reading device, a specific reply is transmitted. We recommend waiting for this reply before transmitting a new command. 10.2 Packet content Each message packet consists of a packet header (header = 3 or 6 characters), the message data (2 or more characters) and the packet end. Packet header Message data Packet end Packet header The packet header contains a start character and the message length. The message length consists of 2 hexadecimal bytes and defines the number of characters in a message. Packet header Start character Length 1 (high byte) Length 2 (low byte) Start Length 1 Length 2 Start character (ASCII character S) High byte of the message length (ASCII character 0-F) Low byte of the message length (ASCII character 0-F) Advanced ASCII-format / Adcanced SZ ASCII-format:
The advanced ASCII format is defined for ASCII messages whose message length exceeds 255 characters. The extended SZ-ASCII format is defined for ASCII messages in which more than 15 antenna ports have to be addressed. The packet header contains two start characters and the message length. The message length consists of 4 hexadecimal bytes and defines the number of characters in a message. Packet header Start 1 Start 2 Length 1 Length 2 Length 3 Length 4 Start 1 Start 2 First start character
(ASCII-character S) Second start character (ASCII-character X = advanced ASCII protocol or Z = advanced SZ ASCII protocol) HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 41 WE GENERATE SOLUTIONS Customer manual LFM 32x WipRack RFID Length 1 Length 2 Length 3 Length 4 High byte of the message length (ASCII-character 0-F) Byte packet length (ASCII character 0-F) Byte packet length (ASCII character 0-F) Low byte of the message length (ASCII character 0-F) Message data The message contains a command character, a target or source address, the number of the antenna port (head) and the actual message data. The number of the antenna port is not required for all messages. Message data Command Address Data Command Address Data The command is defined by an ASCII character. (See protocol commands) Target/source address (ASCII characters 0, 1, . 001F) *
The definition of the message data depends on the protocol command.
*) The LFM 32x WipRack Reader only supports the advanced SZ ASCII protocol to address the readers via 2 ASCII character address 00 1F. Packet end The end of the packet contains an end character and a checksum consisting of 4 characters. Packet end End character Checksum 1 Checksum 2 Checksum 3 Checksum 4 End character ASCII end character <CR> (hex 0x0D). Checksum 1 High byte XOR logic of all data (packet header, data and end character).
(ASCII character 0F) Checksum 2 Checksum 3 Low byte XOR logic of all data (packet header, data and end character).
(ASCII character 0F) High byte addition of all data (packet header, data and end character).
(ASCII character 0F) HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 42 WE GENERATE SOLUTIONS Customer manual LFM 32x WipRack RFID Checksum 4 Low byte addition of all data (packet header, data and end character).
(ASCII character 0F) The checksum is not necessary when using the TCP/IP interface (No transmission). The end character is only transmitted. If the device is operated in ASC-W1 mode, the complete end packet is transmitted (end character and 4 bytes checksum). HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 43 WE GENERATE SOLUTIONS 10.3 Data elements Customer manual LFM 32x WipRack RFID The data elements that are used by default ASCII messages, which are described in the message details section, are defined in this section. Tuning value 2 Byte The tuning value is a set value for the optimal antenna tuning. For optimum read and write ranges, the value is automatically determined by the reader. The value is measured in 16 steps (0-F). He can also be targeted. Example:
08 10 1F automatic tuning from the reader manual tuning 0x00 manual tuning 0x0F CMD 1 Byte Command of the message, see table in Chapter Commands. COLUMN 3 Bytes The column is displayed as 3 ASCII characters (3 bytes) in hexadecimal format (000 to FFF). Column defines the column (X position) of the cursor. Position 0 is on the left. The display text is written from this position. The number of columns depends on the type of display used. Depending on the display command used, the column value is ignored or interpreted as a pixel value. (see data element DspCmd) Valid range:
do not care Pixel 0 - 249 Pixel 0 - 211 DspCmd 0x10 - 0x17 2-colour EInk-Displays black, white 3-colour EInk-Displays black, white, red/yellow If you write outside the valid range (right), these characters are ignored. Data 16 Bytes The data is represented in HEX format by 2 ASCII characters. The data always includes every 8 bytes of the corresponding page of the transporter. Example:
Transponder data in ASCII-Format HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 12345678
(8 bytes) back to the table of contents www.hermos.com 44 WE GENERATE SOLUTIONS Customer manual LFM 32x WipRack RFID Transponder data in HEX-Format Data in message 0x31 0x32 0x33 0x34 0x35 0x36 0x37 0x38 3132333435363738
(16 ASCII-characters) DspArg 3 Bytes Additional arguments for display write. For future development. DspCmd 2 Bytes Command of the display data write message. The command is displayed as 2 ASCII characters (2 bytes) in hexadecimal format (00 to FF). DspCmd Funktion Command 10 (0x10) Write Display (black/white) max. 4 lines with up to 20 characters each 11 (0x11) 14 (0x14) 15 (0x15) 20 (0x20) 21 (0x21) 30 (0x30) Write Display (white/black) max. 4 lines with up to 20 characters each Write Display with header
(black/white) max. 4 lines with up to 20 characters each Write Display with header
(white/black) max. 4 lines with up to 20 characters each Delete display and write data on display (black / white) with update. Starting pixel row and column max. 4 lines with xx characters Delete display and write data on display (white / black) with update. Starting pixel row and column max. 4 lines with xx characters Write display (black / white) without first deleting the display memory and with display update. Starting pixel row and column Display Data 1 64/80 (ASCII) Data depends on font size (see FONT) 1 64/80 (ASCII) Data depends on font size (see FONT) 1 64/80 (ASCII) Data depends on font size (see FONT) 1 64/80 (ASCII) Data depends on font size (see FONT) 1 64/80 (ASCII) Data depends on font size (see FONT) 1 64/80 (ASCII) Data depends on font size (see FONT) 1 64/80 (ASCII) Data depends on font size (see FONT) HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 45 WE GENERATE SOLUTIONS Customer manual LFM 32x WipRack RFID 31 (0x31) 32 (0x32) 33 (0x33) 80 (0x80) F0 (0xF0) F1 (0xF1) F2 (0xF2) F3 (0xF3) max. 4 lines with xx characters Write display without first deleting the display memory (white / black) with update. Starting pixel row and column max. 4 lines with xx characters Write display (black / white) without first deleting the display memory and without an update Starting pixel row and column max. 4 lines with xx characters Write display (white / black) without first deleting the display memory and without updating Starting pixel row and column max. 4 lines with xx characters Negate display white pixels black Write the data in the internal display data structure and then update the entire display. Max. 4 lines with up to 20 characters. The display is updated with the display command
"10" (0x10). Write the data in the internal display data structure and then update the entire display. Max. 4 lines with up to 20 characters. The display is updated with the display command
"11" (0x11). Write the data in the internal display data structure and then update the entire display. Max. 4 lines with up to 20 characters. The display is updated with the display command
"14" (0x14). Write the data in the internal display data structure and then update the entire display. Max. 4 lines with up to 20 characters. The display is updated with the display command
"15" (0x15). 1 64/80 (ASCII) Data depends on font size (see FONT) 1 64/80 (ASCII) Data depends on font size (see FONT) 1 64/80 (ASCII) Data depends on font size (see FONT)
1 64/80 (ASCII) Data depends on font size (see FONT) 1 64/80 (ASCII) Data depends on font size (see FONT) 1 64/80 (ASCII) Data depends on font size (see FONT) 1 64/80 (ASCII) Data depends on font size (see FONT) HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 46 WE GENERATE SOLUTIONS Customer manual LFM 32x WipRack RFID DspLen 2 Bytes The DspLen is displayed as 2 ASCII characters (2 bytes) in hexadecimal format (00 to FF). The DspLen defines the length of the following display data DspData. DspData DspLen Characters The display data are output directly without any further conversion. From every display character the ASCII-code ist tranfered as one byte. Example: AB12 will transferred as 0x41, 0x42, 0x31 and 0x32 (ASCII-code of characters) FONT 2 Bytes The FONT is displayed as 2 ASCII characters (2 bytes) in hexadecimal format (00 to FF). Definition of the font size of the display text to be written. Available fonts are Arial 6 pt, 8 pt, 10 pt, 12pt, 14pt, 20pt, 24pt, 28pt, 40pt, 48pt The automatic line break is carried out after 16 or 20 characters, depending on the font size used. Font:
6 pt, 8 pt, 10 pt line break after 20 characters, next line 30 pt. 12 pt, 14 pt line break after 16 characters, next line 30 pt. 20 pt 24 pt 28 pt 40 pt 48 pt line break after 14 characters, next line 30 pt. line break after 12 characters, next line 30 pt. line break after 10 characters, next line 36 pt. line break after 8 characters, next line 50 pt. line break after 6 characters, next line 60 pt. If an undefined font size is specified or the data element is not specified, the default font size 12 pt. (see parameter default display font) is automatically used. Line 3 Bytes The Line is displayed as 3 ASCII characters (3 bytes) in hexadecimal format (000 to FFF).LINE defines the line (Y position) of the cursor. Position 0 is up. The display text is written from this position. The number of lines depends on the type of display used. Depending on the display command used, the line value is interpreted as line 0-3 or as a pixel value. (see data element DspCmd) HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 47 Customer manual LFM 32x WipRack RFID WE GENERATE SOLUTIONS Valid range:
DspCmd 0x10 - 0x17:
Line 0 - 3 DspCmd>0x20:
Pixel 0 - 121 2-colour EInk-Displays black, white Pixel 0 - 103 3-farbige EInk-Displays black, white, red/yellow If the valid area is written beyond (below), these characters are ignored. Output Index 1 Byte The Output Index defines the index of the output of a Readerhead that is addressed. Each Readerhead has 2 LEDs. Example:
1 2 3 4 5 LED1 of the port (red) LED2 of the port (green) red status LED yellow status LED LED1 and LED2 (yellow) Output State Output State 4 Bytes 4 Bytes The data element shows or sets the current status of the outputs. The Data Element Output State includes the status of each output on the reader. The status is displayed as 1 byte for each sensor. 0 1 2 3 4 Switch off the output permanently Switch on the output permanently output flashes with approx. 1 Hz output remains unchanged output flashes with approx. 2 Hz Parameter No. 1 Byte The number of the parameter is displayed as an ASCII character (1 byte) in HEX format. Example:
Parameter 1 Parameter 2 Parameter 15 1 2 F Parameter Value 2 Bytes With single-digit parameter numbers from 0 to F, the actual parameter value can be decimal or hexadecimal depending on the mode. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 48 WE GENERATE SOLUTIONS Customer manual LFM 32x WipRack RFID In the standard ASC-I1 mode, the data element displays the value of a parameter using 2 ASCII characters (2 bytes) in decimal format (00 bis 99). Example:
Value 45 45 In ASC-W1 mode the data element indicates the value of a parameter by means of 2 ASCII characters (2 bytes) in hexadecimal format (00 to FF). Example:
Value 45 (decimal) 2D(hexadecimal) HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 49 WE GENERATE SOLUTIONS Customer manual LFM 32x WipRack RFID Reader-ID Output State 2 Byte 4 Bytes The reader ID defines the address of the antenna port. The reader LFM 32x can be read at all 32 antenna ports (1-32). The antenna port is selected via the reader ID and is continuous. For advanced SZ ASCII protocol up to 32 antenna ports can be addressed by a 2 ASCII characters reader ID 00 up to1F. General messages also possible at address FF (HFF). Response-Code 4 Bytes This feature is not required for the individual device. This code is always 0000. Page 1 Bytes The page of the transponder for a read / write operation is defined by 2 ASCII characters
(2 bytes) in decimal format Example:
Page 1 01 Page 10 10 Page 17 17 If the device is operating in ASC-W1 mode, the page should be interpreted in hexadecimal form:
The page of the transponder for a read / write operation is defined by 2 ASCII characters (2 bytes) in hexadecimal format. Example:
Page 1 01 (81 if page is locked) Page 10 0A (8A if page is locked) Page 17 11 (91 if page is locked) Read/Only F0 Read/Write F1 HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 50 WE GENERATE SOLUTIONS Customer manual LFM 32x WipRack RFID Serial number 4 Bytes Contains 4 byte of the serial number. The serial number is also on the adhesive label of the device. Example:
1707HAG04660 complete serial number Decimal 04660 (the last 5 characters of the complete serial number) Hexadecimal serial number 1234 The gateway ID is the last two digits and has the value 0x34 Software version 16 Bytes The data item contains the software version currently used in the reader. The version string is displayed with up to 16 characters. Example:
4C464D3449312E35 hex-String
(LFM4I1.5) Timeout 2 Bytes The data element Timeout defines the period of time that elapses until the LEDs are switched off. The timeout is defined in hexadecimal notation. When the timeout expires, the LED turns off. Example:
00 01 bis FF ... 1 s bis 255 s Timeout
... permanently on HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 51 Customer manual LFM 32x WipRack RFID WE GENERATE SOLUTIONS 10.4 Protocol Commands Read:
Command Description X R Write:
Read Data Automatic Read Command Description W Write Data Device-Settings:
Command Description G F P N e E H V L l J Query Parameter Query Parameter (Device is operated in ASC-W1 mode) Set Parameter Reset Error message Error message (Device is operated in ASC-W1 mode) Heartbeat Software-Version Lock side of a transponder Coordinate RF-modules Querying the coordination of the RF-module In- and Output:
Command Description O Q Set Output Query Output/Input State HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 52 WE GENERATE SOLUTIONS Customer manual LFM 32x WipRack RFID A B Sensor event: Sensor removed Sensor event: Sensor detected (Device is operated in ASC-W1 mode) Display:
Command Description D Write to Display HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 53 Customer manual LFM 32x WipRack RFID WE GENERATE SOLUTIONS 10.4.1 X - Read data Host Device CMD X Reader-ID Page Readlength 2 Bytes *) 2 Bytes 2 Bytes
*) only advanced SZ ASCII protocol supported !
Device Host CMD x Reader-ID Page Data 2 Bytes *) 2 Bytes 16 Bytes
*) only advanced SZ ASCII protocol supported !
The data element page can have the following values:
Page Description 01 17 Read # page 98 99 Read multiple pages to the end character or a blank character 1) Read out all transponder data 1) E or F in ID, Bit 03 of the read ID In ASC-W1 mode, the data element page can have the following values:
Page Description 01 11 Read page # of a multipage transponder F0 F1 Read/Only transponder Read/Write transponder HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 54 WE GENERATE SOLUTIONS Customer manual LFM 32x WipRack RFID 00 Read the first page of all transponder types If there is no transponder in the reading range of the antenna, the reader repeats the reading function several times before an error message is sent. The number of repetitions is defined in parameter 4 (r / w maxrepeat). If reading is still not possible, the reader sends the error message no tag (4) to the host after the repetitions have been carried out. No confirmation is expected from the host. For a multipage read request (98 or 99), the protocol is retried. At the end of reading, the reader sends an additional packet. If the sensor check is activated (parameter 1: readmode), the assignment of the external input is checked before the initiation of a read process by the host. The reading process is only started if the sensor is occupied, otherwise the error message no tag (4) is sent. 10.4.2 R Automatic read By assigning the external input, an automatic read operation can be triggered. The command R sends the read data to the host. The host then has to confirm the message. Depending on the setting of the reader (parameter 1: readmode), the reader reads the following pages:
Read Mode:
0 Reading the page defined in parameter 2 (readpage) 1 sequential reading of a transponder to the end character
(E - end character or F empty) in ID bit 0 ... 3 2 Reading the entire transponder (all pages) Device Host CMD R Reader-ID Page Data 2 Bytes *) 2 Bytes 16 Bytes **)
*) only advanced SZ ASCII protocol supported !
Host Device CMD r Reader-ID 2 Bytes *)
*) only advanced SZ ASCII protocol supported !
HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 55 WE GENERATE SOLUTIONS Customer manual LFM 32x WipRack RFID When reading several pages (par. 1: readmode tag or everything) the command is repeated for each read page. The last package contains the command R and the reader ID. The host expects a confirmation of the read data. If there is no confirmation from the host, the command is repeated. (par.5: RS232 repeat time, par.6: RS232 maxrepeat). If a reading is not possible, the reader automatically repeats the reading with the set parameters. (par.3: r / w delay time, par.4 r / w maxrepeat). If no reading is possible, the reader sends the error message no tag (4) to the host. The delay time for the presence sensor can be set (parameter 0: sensor delay). An automatic reading is only possible if all messages to be confirmed have been confirmed by the previous reading or the waiting time (par.5: RS232 repeat time, par.6: RS232 maxrepeat) has elapsed after the last transmission. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 56 WE GENERATE SOLUTIONS 10.4.3 W - Write data Customer manual LFM 32x WipRack RFID The command W starts writing a defined data area of a transponder. If there is no transponder in the write range of the antenna, the reader sends an error message (error 4 - no transponder). Host Device CMD W Reader-ID Page Data 2 Bytes *) 2 Bytes 16 Bytes
*) only advanced SZ ASCII protocol supported !
Device Host CMD w Reader-ID 2 Byte *)
*) only advanced SZ ASCII protocol supported !
If the describing of the tag fails, the reader repeats the writing operation several times before sending an error message. The number of repetitions is defined in parameter 4 (r / w maxrepeat). If writing is still not possible, the reader sends the error message no tag (4) to the host after the repetitions have been carried out. If the sensor check is activated (parameter 1: readmode), the assignment of the external input is checked before the start of the write process by the host. The write process is started only when the sensor is busy, otherwise the error message no tag (4) is sent. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 57 WE GENERATE SOLUTIONS 10.4.4 G Query parameter Customer manual LFM 32x WipRack RFID With the command G the values of all public parameters of the device can be queried. Host Device CMD G Device Host CMD g Reader-ID 2 Bytes *) Reader-ID Parameter No. Parameter Value 2 Bytes *) 1 Byte 2 Bytes
*) only advanced SZ ASCII protocol supported !
The reader sends an individual protocol packet for each available public parameter. After the last parameter, the reader sends a last packet including the command g and the reader ID. From the list of public parameters only the parameter 0 to 7 and parameter F will be send. The values returned for the data item parameter value in the response are decimal values
(00-99). The values for the data item Parameter No. are hexadecimal values (0-F). HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 58 WE GENERATE SOLUTIONS 10.4.5 F Query parameter Customer manual LFM 32x WipRack RFID The command F can be used to query the value of a public parameter of the device. Host LF Device CMD F Reader-ID 2 Bytes *) Parameter No. 1 Byte Device Host CMD f Reader-ID Parameter No. Parameter Value 2 Bytes *) 1 Byte 2 Bytes
*) only advanced SZ ASCII protocol supported !
The reader sends an individual protocol packet for the requested public parameter. The values returned in the response for the data elements parameter number and parameter value are each hexadecimal values (0-F or 00-FF). In the case of two-digit hexadecimal parameter numbers (Parameter No.), the parameter number and the parameter value double-digit hexadecimal are also used in the response. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 59 WE GENERATE SOLUTIONS 10.4.6 P Set parameter Customer manual LFM 32x WipRack RFID The command P can be used to change the value of individual parameters. After a parameter has been successfully changed, the reader sends a confirmation message. Host Device CMD P Device Host CMD p Reader-ID Parameter No. Parameter Value 2 Bytes *) 1 Byte 2 Bytes Reader-ID 2 Bytes *)
*) only advanced SZ ASCII protocol supported !
Depending on the Factoryparameterset selected, the data elements parameter number and parameter value must be interpreted differently. For single-digit hexadecimal parameter no. the following interpretations must be observed:
In the standard ASC-I1 protocol mode the data element Parameter Value with decimal values
(00-99) has to be used. The values for the data item Parameter No. are hexadecimal values
(0-F). Only in ASC-W1 mode (Factoryparameterset 3) the data elements Parameter No. and Parameter Value have to be used as hexadecimal values (0-F or 00-FF). For two-digit hexadecimal parameter numbers (Parameter No.), the parameter value must always be sent in two digits hexadecimal. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 60 WE GENERATE SOLUTIONS 10.4.7 N Reset Customer manual LFM 32x WipRack RFID The command N performs a reset of the hardware/software of the reader. After performing the reset operation, the device sends a confirmation message. Host Device CMD N Device Host CMD n Reader-ID 2 Bytes *) Reader-ID 2 Bytes *)
*) only advanced SZ ASCII protocol supported !
After a hardware reset, a confirmation (n00) is sent to the host. If TCP / IP is used as the interface, the host will not receive an acknowledgment, because an existing TCP/IP connection is interrupted by the reset. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 61 WE GENERATE SOLUTIONS 10.4.8 e Error message Customer manual LFM 32x WipRack RFID This message is only available in standard ASC-I1 mode!
If an error occurs the device will send an error message with the respective error code. Device Host CMD e Reader-ID 2 Bytes *) Error ID 1 Byte
*) only advanced SZ ASCII protocol supported !
Further information about error codes and the corresponding corrective measures can be found in the chapter Error Codes. 10.4.9 E Error message This message is only available in ASC-W1 mode. If there is an error, the device sends an error messa- ge with the appropriate error code to the host. The reader expects a confirmation of the error message. If there is no confirmation from the host, the command is repeated. (Par.5: RS232 delay time, par.6: RS232 maxrepeat). Device Host CMD E Reader-ID 2 Bytes *) Error ID 1 Byte
*) only advanced SZ ASCII protocol supported !
More about error codes and the corresponding corrective measures can be found in the chapter Error Codes. Host Device CMD e Reader-ID 2 Bytes *)
*) only advanced SZ ASCII protocol supported !
HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 62 WE GENERATE SOLUTIONS 10.4.10 H Heartbeat Customer manual LFM 32x WipRack RFID The command H sends a heartbeat request to the reader. The reader responds with its serial number and a response code. Host Device CMD H Device Host CMD h Reader-ID 2 Bytes *) - also Reader ID FF allowed Reader-ID Serial number Response-Code 2 Bytes *) 4 Bytes 4 Bytes
*) only advanced SZ ASCII protocol supported !
The heartbeat function can be performed for all 4 antenna ports (1-4). If another reader is operated as a customer variant on the RS232 port, a heartbeat can be sent to the external reader via reader ID 5. The response code is part of the protocol but is not used for this device. The response code is always 0000. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 63 WE GENERATE SOLUTIONS 10.4.11 V Query software version Customer manual LFM 32x WipRack RFID The command V is used to query the software version of the device. Host Device CMD V Device Host CMD v Reader-ID 2 Bytes *) Reader-ID 2 Bytes *) Software version 16 Bytes
*) only advanced SZ ASCII protocol supported !
The 8 characters of the software version are represented by 16 ASCII characters. Each character is described in hex format and transmitted by 2 ASCII characters. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 64 WE GENERATE SOLUTIONS 10.4.12 L - Lock data area Customer manual LFM 32x WipRack RFID A single page of a multipage transponder can be disabled. The page can still be read, but not rewritten. The process cannot be reversed. Host Device CMD L Device Host CMD L Reader-ID 2 Bytes *) Pages 2 Bytes Reader-ID 2 Bytes *)
*) only advanced SZ ASCII protocol supported !
If the lock of the transponder page fails, the reader repeats the procedure several times before an error message is sent. The number of repetitions is defined in parameter 4 (r / w maxrepeat). If writing is still not possible, the reader sends the error message no tag (4) to the host after the repetitions have been carried out. If the page was already locked, a positive confirmation will be sent (same as the first block). If the sensor check is activated (parameter 1 readmode), the assignment of the external input is checked before the blocking process is started by the host. The locking process is only started when the sensor is occupied, otherwise the error message no tag (4) is sent. Locking a page cannot be reversed. This page is permanently write protected. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 65 WE GENERATE SOLUTIONS 10.4.13 I Adjust RF module Customer manual LFM 32x WipRack RFID It is necessary to adjust the RF module in ordert to adapt an antenna tot he ambient conditions optimally. The tuning achieves an optimal read / write range for the present installation environment. Tuning is performed one at a time for each antenna port and the determined tuning value is stored for each antenna. For optimal results, the vote should be automatic, but the voting value can also be set manually. Host Device CMD I Device Host CMD i Reader-ID Tuning Value 2 Bytes *) 2 Bytes Reader-ID 2 Byte *)
*) only advanced SZ ASCII protocol supported !
To start the auto-tuning process, select the value 08. Example:
I0008 automatic tuning of antenna 1 If the reader can not determine the appropriate calibration, the error 5 - Invalid is sent instead of the confirmation. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 66 WE GENERATE SOLUTIONS 10.4.14 J RF module Queries the vote Customer manual LFM 32x WipRack RFID The command J can be used to query the tuning values of the individual antennas. Each antenna port has its own tuning value. Host Device CMD J Device Host CMD j Reader-ID 2 Bytes *) Reader-ID 2 Bytes *) Tuning value 2 Bytes
*) only advanced SZ ASCII protocol supported !
The tuning value is a set value for the optimal antenna tuning. For optimum read and write ranges, the value is automatically determined by the reader
(I-message). The tuning value is measured in 16 steps (0-F). HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 67 WE GENERATE SOLUTIONS 10.4.15 A Sensor event object removed Customer manual LFM 32x WipRack RFID The message of sensor events can be activated in the parameter Watch-Port (par. 07). If this is activated, the reader reports every drop of the external sensor. The sensor message must be confirmed by the host. Host Device CMD A Reader-ID 2 Bytes *) LF Lesegert Host CMD a Reader-ID 2 Bytes *)
*) only advanced SZ ASCII protocol supported !
The sensor event is detected after an adjustable delay time (par. 0 Sensor Delay). During the delay time, the sensor signal must be stable. In parameter 1 Read Mode the sensor can be deactivated. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 68 WE GENERATE SOLUTIONS 10.4.16 B Sensor event object detected Customer manual LFM 32x WipRack RFID The message of sensor events can be activated in the parameter Watch-Port (par. 07). If this is activated, the reader reports any recognition of the external sensor. The sensor message must be confirmed by the host. Host Device CMD B Device Host CMD b Reader-ID 2 Bytes *) Reader-ID 2 Bytes *)
*) only advanced SZ ASCII protocol supported !
The assignment of the external sensor results in an automatic reading and is not sent as a sensor event in standard ASC-I1 mode. In the ASC-W1 mode, however, a sensor event B is present. In parameter 1 Read Mode the sensor can be deactivated. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 69 WE GENERATE SOLUTIONS 10.4.17 O Set output Customer manual LFM 32x WipRack RFID The command O can be used to set the state of the outputs. The status of all outputs is changed in a message. In the current version, the value of the data element Head-ID always has the value 1 for the outputs. Host Device CMD Reader-ID Head-ID Output Index Output State Timeout **) O 2 Bytes *) 1 Byte 1 Byte 1 Byte 2 Bytes Device Host CMD o Reader-ID 2 Bytes *) Head-ID 1 Byte
*) only advanced SZ ASCII protocol supported !
**) The specification of a time duration (timeout) is optional. Example:
permanently switch on LED 1 (red):
>> O0111100
<< 0011 Turn red status LED on for 10 seconds:
>> O011310A
<< 0011 The number of available outputs depends on the reader version used. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 70 WE GENERATE SOLUTIONS Customer manual LFM 32x WipRack RFID 10.4.18 Q Querying the status of the inputs and outputs The Q command can be used to query the current status of all outputs. The status of the outputs is queried in a message. In the current version, the value of the data element Head-ID always has the value 1 for the outputs. Host Device CMD Q Device Host Reader-ID 2 Bytes *) Head-ID 1 Byte CMD Reader-ID Head-ID Output State LED1 Output State LED2 q 2 Bytes *) 1 Byte 1 Byte 1 Bytes
*) only advanced SZ ASCII protocol supported !
Example:
>> Q011
<< q01121 LED1 (2 = flash), LED2 (1 = on) Status LEDs Port 01 HeadID=1 The status of all 4 (The number of sensor states may vary between 4 and 6, depending on the customer mode.) input sensors can be queried via head ID 0. In this case, the answer contains the 4 (The number of sensor states may vary between 4 and 6, depending on the Factoryparameterset.) sensor states instead of the 2 output states. Status of all sensors HeadID=0 Example:
>> Q010
<< q01010000000000000000000000000000000 Only sensor of Port1 is detected ! The other sensors from ports 2 up to 32 are released. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 71 WE GENERATE SOLUTIONS 10.4.19 D Write to Display Customer manual LFM 32x WipRack RFID The D command can be used to write display commands to a serial connected E-Ink display. The E-Ink display used enables 4 lines to be written with up to 20 characters per line. The number of lines and characters per line depends on the font size used. Host Device CMD Reader-ID DspCmd DspArg Column Line Font DspLen DspData D 2 Bytes *) 2 Bytes 3 Bytes 3 Bytes 3 Bytes 2 Bytes 2 Bytes DspLen Bytes Device Host CMD Reader-ID d 2 Bytes *)
*) only advanced SZ ASCII protocol supported !
Replace two display lines of dipslay output (cmd 0xF0 :=update data of internal Example:
display structure and write the displaystructure to display), Start at line-index 1 and column-index 0. The fontsize 12 indicates 16 characters per line !
>> D00F00000000010C20Test112345678911Test223456789222
<< d00 HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 72 WE GENERATE SOLUTIONS 10.5 Parameter Customer manual LFM 32x WipRack RFID The parameters 0, 1, 2 and 7 are only valid if the reader is equipped with a corresponding I / O module and provides one input per antenna port.
*): Some parameters are implemented for each antenna port. Addressing of the parameter takes place via the reader ID of the message. In this realisation, the parameter is present once per antenna port. If no parameter arrays should be used, please ask the manufacturer (parameter 63)!
10.5.1 Parameters ASC-I1 Mode The data element Parameter No. can have the following values. List of public paramters:
Nr.
(dez) Nr.
(hex) Parameter name 0 0x00 Sensor delay 1 0x01 Read mode Description Delay time for the presence sensor. 01 .. 99 (0,1 Sekunden) Default: 10 (1 second) Realisation: a separate parameter for each port *) Read mode for reading automatically started by external input. 00 - read only one page 01 - read until the end character or empty character2) 02 - read all pages 10 - read only one page with previous sensor Check1) 11 - read until the end character / empty character with previous sensor check 1) 2) 12 - read all pages with previous sensor Check1) 99 - Disable sensor 1) If the Sensor Check (first byte = 1) is activated, the assignment of the potential-free input is checked before initiating a read / write process. When used, the read / write process is started, otherwise the error message NOTAG is sent. 2) E or F in ID bits 0...3 of the read ID Default: 00 (read only one page) Realisation: a separate parameter for each port *) HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 73 WE GENERATE SOLUTIONS Customer manual LFM 32x WipRack RFID 2 0x02 Read page Page for readmode 00. First page of each transponder 02.. 17 Side of a multipage transponder Default: 01 (read first page) Realisation: a separate parameter for each port *) 0x03 r/w repeat time 4 0x04 r/w max repeat Time between two read / write attempts. 01 .. 99 (0,1 s) Default: 05 (0,5 seconds) Realisation: a separate parameter for each port *) Max. number of read / write attempts. 01 .. 99 Default: 05 Realisation: a separate parameter for each port *) 5 0x05 RS232 repeat time 6 0x06 RS232 max repeat If no confirmation message was received from the host, the device waits for this time before sending another message. The number of repetitions is defined in parameter 6 (RS232 max repeat). 01 .. 99 (0,1 s) Default: 45 (4,5 seconds) If an acknowledgement is not sent by the host, the device repeats the message according to the set value. Only then is an error message sent. 00 - endless 01 .. 99 - Number of attempts Default: 3 Activates / deactivates the event message to the host that the dry contact (external output) has been opened (Bit0). 7 0x07 Watch port Bit0 (=0x01) reporting of contact has been opened:
0 - deactivated 1 activated For CFP4 setting the Bit1 is also available. See ASC-W1 parameter7. F 0x0F Reader address Default: 1 Realisation: a separate parameter for each port *) Address of the first antenna port (00 ... 1F) Default: 0 HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 74 WE GENERATE SOLUTIONS 10.5.2 Additional Parameters ASC-W1 Mode Customer manual LFM 32x WipRack RFID For ASC-W1 mode (factoryparameterset 3) the following additional parameters are public:
Nr.
(dez) Nr.
(hex) Parameter name 2 0x02 Read page 7 0x07 Watch port 8 9 0x08 Fieldstrength 0x09 Charge time 10 0x0A Verify 11 0x0B Fallout Description Page for readmode 00. 00 First page of each transponder 01 17 Side of a multipage transponder Default: 00 (read first page) Realisation: a separate parameter for each port *) Activates / deactivates the event message to the host that the dry contact (external output) has been opened (Bit0) or closed (Bit1). Bit0 (=0x01) reporting of contact has been opened:
0 - deactivated 1 - activated Bit1 (=0x02) reporting of contact has been closed:
0 - deactivated 1 activated Default: 1 Realisation: a separate parameter for each port *) Parameter is without further function. Range: 00-01 Default: 1 Transponder charging time in milliseconds. Range: 00-FF Default: 32(50ms) Realisation: a separate parameter for each port *) Parameter is without further function. Range: 00-03 Default: 1 Parameter is without further function. Range: 00-03 Default: 1 12 0x0C RS232 repeat time Parameter is without further function. Range: 00-FF Default: 0 13 0x0D Noiselevel adjust Parameter is without further function. Bereich: 00-FF Default: 0 14 0x0E Sensor polarity Type of sensor signal to start an automatic read. The setting is applied for the addressed sensor. 0 read process when sensor is covered 1 read process when sensor is uncovered Default: 0 Realisation: a separate parameter for each port *) HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 75 WE GENERATE SOLUTIONS 10.5.3 Additional Parameters Customer manual LFM 32x WipRack RFID
*): Some parameters are implemented for each antenna port
(parameter array). Addressing of the parameter takes place via the reader ID of the message. In this realisation, the parameter is present once per antenna port. See parameter 32 Bit2 parameter array activation/deactivation Nr.
(DEZ) Nr.
(HEX) Parameter name Description 19 0x13 Data length autoread The parameter determines the number of bytes read from the tag during an automatic read 0 136 (maximale 17 pages !!) Default:
Realisation: a separate parameter for each port *) 8 Databytes The sensor activity of head is represented by a bit. 0 Sensor not activated 26 0x1A Sensor Activity 1 Sensor activated 29 0x1D Transponder load duration
(read mode) 30 0x1E r/w synchronize 32 0x20 Feature Setup 1 50 (50ms) Default:
Realisation: a separate parameter for each port *) Charging time of a transponder during the reading process. The default setting should not be changed. Default:
Realisation: a separate parameter for each port *) Activates / deactivates the synchronization of the reader. When synchronization is enabled, the reader detects interference or other active readers and synchronizes the read cycle . 0 synchronization deactivated 1 synchronization activated Default:
1 activated Bit 0: activate Par. 6 ASCII_RETRY for ASC-W1 Bit 1: activate Par. C ASCII_T3 for ASC-W1 Bit 2: 0: ues parameter arrays; 1:no parameter array Bit 3: 0: set min. sensortimeout of 100ms for value 0 Bit 4: For value 1 the parameter F will not be tranfered for ASCI-I1 command G. Bit 5: Port LEDs will be affected by read and sensor actions Bit 6: 0: wait for display response; 1: no wait Bit 7: 0: save sensor event if another sensor event is still running; 1: send error AUTOREADFAIL if another sensor event (autoread !!) is still running HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com Default:
0x01 (0000 0001) LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 76 WE GENERATE SOLUTIONS Customer manual LFM 32x WipRack RFID
... reading after detected sensor
... Do not execute a read after reset, when the
... execute read operation after reset, when sensor is Bit 0: After a hardware reset, the reader will auto-read if the presence sensor is covered. 0 covered 1 sensor is covered (standard) Bit 1: Trigger sensor-triggered automatic read opera-
tion 0 trigger
... No automatic reading with detected sensor 1 Bit 2: 0: non volatile memory is used for saving the reader ID at reset process Bit 2: 1: non volatile memory ist not used Bit 3: not documented Bit 4: set external head LED1 at sensor triggered read Bit 5: page transfer when reading the first page of a multipage transponder 0 ... without page transfer 1 ... with page transfer Bit 6: external head LED1 will be influenced at ASC-
W1 mode Bit 7: external head LED2 will be influenced at ASC-
W1 mode Default:
0x01 (0000 0001) Bit 0 to bit 4 defines the behavior of the four externally accessible DIP switches. Bit0: DIP 4 active Bit1: DIP 3 active Bit2: DIP 2 active Bit3:
DIP 1 active Bit4: Value (1): If no test mode is activated (DIP3 =
OFF), the set antenna port (via DIP1 and DIP2) is tuned automatically by changing the DIP 4 from OFF to ON. If tuning is successful, the adjustment for the port is saved and the Status LED is switched on. 0x1F Default:
This parameter activates / deactivates the initial test after a software reset . 0 No initial test after software reset 1 initial test after software reset Default:
0 Charging time of a transponder during the writing process. The default setting should not be changed 50 (50ms) Default:
Delay time between two read cycles. A reduction of the delay increases the reading speed. 1 .. 250 (1 ms) Default:
10 (10ms) 35 0x23 Special Features 36 0x24 DIP switch activation 38 0x26 Test after software reset 40 0x28 Transponder load duration
(write mode) 41 0x29 Delay time between read cycles HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 77 WE GENERATE SOLUTIONS Customer manual LFM 32x WipRack RFID 64 0x40 Customer Factory Parameter CFP (read only) This parameter is only for factory time, to define a special customer behaviour (CFP). Parameter should not be changed by customer!
Default:
3 70 0x46 Software Version String
(read only) The read-only parameter returns the complete identifier of the current firmware. 71 0x47 Serial number string
(read only) The read-only parameter provides the complete serial number string. 72 0x48 Hardwarerevision String
(read only) The read-only parameter provides the complete identifier for the hardware version. 75 0x4B DIP switch status
(read only) 76 0x4C Saved fatal errors or events
(read only) 83 0x53 Display Response Wait Time 84 0x54 Antenna tuning of the addressed antenna 86 0x56 Display Waiting Time 87 0x57 Display default FONT The parameter is used to query the position of all DIP switches. Bit0: DIP 4 (0=off, 1=on) Bit1: DIP 3 (0=off, 1=on) Bit2:
DIP 2 (0=off, 1=on) Bit3: DIP 1 (0=off, 1=on) The result is independent of parameter 36 (0x24). The read-only parameter retrieves all errors and events stored in a ring memory. Since only about 25 characters are read out of the memory per call, it may need to be retrieved several times until it is completely emptied. Fatal errors and the creation of default parameters will be saved. Max. time to wait for a display response, if feature waiting for response is activated. 00 ... 255 time factor 20ms Default: 150*20ms=300ms By automatically adjusting the antenna, the influence of ambient conditions can be minimized 00 ... 15 value of antenna adjustment Default: 08 Realisation: a separate parameter for each port *) Waiting time as long as the maximum waiting for the output of the remaining characters before the next output on a display. 0no waiting time 1200 waiting time in 5ms steps Default: 100 (500ms) If the display write command does not contains a valid value for the item FONT than the parameter value default display font is used. The value range ist between 6 and 48 pt. See item FONT for recommended values!
HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com Default: 12 (12pt) LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 78 WE GENERATE SOLUTIONS 88 0x58 Display linesize
(read only) 89 0x59 Display max datasize
(read only) 96 0x60 Set default parameters 97 0x61 Default protocol
(read only) 98 0x62 Protocol change allow
(read only) Customer manual LFM 32x WipRack RFID The number of characters within a line depends on the selected FONT. This parameter delivers the number of character within a display line from the last display writing command. Only the display commands 0x1x and 0xFx distribute this parameter. Default: 16 characters per line for default FONT 12pt Realisation: a separate parameter for each port *) The number of characters within a line and the number of lines depends on the selected FONT. This parameter delivers the number of character within all display lines from the last display writing command. Only the display commands 0x1x and 0xFx distribute this parameter. Default: 64 characters for default FONT 12pt Via this parameter default parameters of the reader can be established. Factor setting parameters remain unaffected!
0... reset all parameters 1... reset all parameters except network settings The query of the parameter returns the fine version of the software version. This parameter provides information about the currently set protocol. 1 SECS protocol (not realized !) 2 ASCII protocol Default: 2 This parameter can be used to allow a detected protocol change. This will then set the new default protocol and restart the device. If the protocol change is suppressed, no automatic change takes place. 0 protocol change not allowed 1 ... protocol change allowed Default: 0 HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 79 Customer manual LFM 32x WipRack RFID WE GENERATE SOLUTIONS 10.6 Message examples Standard ASCII Protocol:
ASCII HEX Description S 53 Start character 0 2 30 High byte message length 32 Lowbyte message length H 48 Message first character: value 0 30 Message second character: destination address CR 0D End character 2 32*) Highbyte Checksum XOR 4 34*) Lowbyte Checksum XOR 3 33*) Highbyte Checksum Addition A 41*) Lowbyte Checksum Addition
*): With TCP / IP transmission in the standard ASC-I1 protocol, the checksum bytes are not transmitted. In ASC-W1 mode, however, they are also transmitted!
Calculation of the XOR checksum:
53 XOR 30 XOR 32 XOR 48 XOR 30 XOR 0D =
24 2 4 Calculation of the addition-checksum:
53 + 30 + 32 + 48 + 30 + 0D =
(LSB is used) 13A 3 A HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 80 WE GENERATE SOLUTIONS Advanced SZ ASCII Protocol:
Customer manual LFM 32x WipRack RFID ASCII HEX Description S 53 Start character Z 5A Second Start character tod identify advanced SZ protocol 0 0 0 3 30 High byte message length (higher byte) 30 Low byte message length (higher byte) 30 High byte message length (lower byte) 33 Lowbyte message length (lower byte) H 48 Message first character: value 0 0 30 High byte destination address 30 Low byte destination address CR 0D End character 4 34*) Highbyte Checksum XOR F 46*) Lowbyte Checksum XOR 2 32*) Highbyte Checksum Addition 5 35*) Lowbyte Checksum Addition
*): With TCP / IP transmission in the standard ASC-I1 protocol, the checksum bytes are not transmitted. In ASC-W1 mode, however, they are also transmitted!
HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 81 WE GENERATE SOLUTIONS Customer manual LFM 32x WipRack RFID Calculation of the XOR checksum:
53 XOR 5A XOR 30 XOR 30 XOR 30 XOR 33 XOR 48 XOR 30 XOR 30 XOR 0D =
34 3 4 Calculation of the addition-checksum:
53 + 5A + 30 + 30 + 30 + 33 + 48 + 30 + 30 + 0D
(LSB is used) 225 2 5 The following examples are based on the standard ASC-I1 protocol. The range of the Reader ID is set from 00 to 1F (antenna port 1 up to 32) in this case:
V Query software version
>> V01
<< v014C5752333249322E31 Command Reader-ID Software version 4C5752333249322E30 ASCII LWR32I2.0 V 01 I automatically tune RF module (antenna port 3)
>> I0208
<< i02 Commandl Reader-ID
(Tuning Antenna port 3) I 02 J RF module Read out tuning value (Antenna port 3)
>> J02
<< j0201 Command Reader-ID Data J 02 (Antenna port 3) 01
(voting value) X Read data (Reading from page 1 of the multipage transponder)
>> X0101
<< x01014142434445464748 Command Reader-ID Page
(reading on antenna port 2) X 01 01 Data4142434445464748 ASCII ABCDEFGH R - Automatic reading on antenna port 2
<< R01013132333435363738
>> r01 Command Reader-ID Page 01 R 01 (automatic reading on antenna port 2) Data4142434445464748 ASCII ABCDEFGH HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 82 WE GENERATE SOLUTIONS Customer manual LFM 32x WipRack RFID W Write data (Write antenna port 3, page 16 Multipage)
>> W02103132333435363738
<< w02 Command Reader-ID Page Data3132333435363738 W 02 (Write to antenna port 3) 10
(10hex = page 16dec.) ASCII 12345678 D Write Display (Write display port 1, cmd 240, font 12pt)
>>D00F00000000000C40Test112345678911Test223456789222Test333456789333Test44 3456789444
<< d00 Command Reader-ID Cmd Arg Colomn Line Font Datalen Data Test112345678911Test223456789222Test333456789333Test443456789444 D 00 (Write to display port 1) F0 (240) 000 000 000 0C (12pt) 40 (64 Zeichen) HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 83 WE GENERATE SOLUTIONS 10.7 Error Codes Customer manual LFM 32x WipRack RFID ID Name Description Possible Cause Corrective action 0 1 2 none No error auto fail ext fail Automatic reading is not possible Execution failed, read or write operation cannot be carried out none Reader is still busy with a former read or write request Wait until the previous request has ended. Reader is still busy with a former read or write request. Wait until the previous request has ended. 3 write fail Data transfer to the tag is not possible. Reader is still busy with a former read or write request. Wait until the previous request has ended. Antenna is not connected properly Check antenna connection Antenna is not tuned Antenna tuning No readable transponder within the reading range Put the transponder in the antenna area. Check the type and function of the transponder Antenna / transponder are misaligned Check the alignment of the antenna and the transponder 4 no tag No transponder or antenna installed Antenna is damaged or too close to metal Replace the antenna, check the tuning 5 invalid Invalid parameter or data 6 unknown Unknown errors 7 Unconfig The device is not configured Interference field at transmission frequency Invalid command data Check antenna environment for possible sources of interference.
(Monitors, servomotors) Check command syntax and data content Parameter is not implemented or out of range Check parameter syntax and value Wrong reader address Wrong baud rate none Check message syntax, check parameter F Reader address Check the baud rate of the serial interface (Com port) 8 check Parity or checksum error Transmission error at serial communication Check RS232 cable and connector, Check sources of interference with RS232 Serial communication is interrupted Check RS232 cable and connector, Check sources of interference with RS232 Ethernet communication is interrupted Check Ethernet cable and connector, check IP address settings 9 void ackn unexpected acknowledge Double or wrong acknowledgment A Locked Locked page cannot be written Tag is write protected Check communication settings at the host Check the page number to be written, exchange the tag for the new one HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 84 WE GENERATE SOLUTIONS B Unconfig Maximum number of send messages has been confirmed
(RS232 maxrepeat), The terminal did not confirm within the specified timeframe C Bad type Wrong transponder type
Msg len Message too long or too short or not received completely
Invalid Invalid command Customer manual LFM 32x WipRack RFID Host system does not acknowledge the message A wrong transponder type is used (Read only or Read / Write instead of multipage) Message too long or too short or not received completely Message is longer than specified in the length byte Not all characters are transfered (Intercharacter Timeout) Unknown command was received Check availability oft he host system, Check RS232 cable and connector Ethernet cable and connector, Check IPAddress settings Check and replace transponder type Message length is longer than indicated on the length byte, Check message length and length byte Check message length, check length byte Check message syntax, Check RS232 or Ethernet connection Check message syntax HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 85 WE GENERATE SOLUTIONS 10.8 Wiring of the outputs Customer manual LFM 32x WipRack RFID For readers with I / O modules, depending on the Factoryparameterset, the outputs of the respective antenna port can be switched accordingly when reading. On default settings the sensor triggered read events will not affect the ports leds LED1 and LED2. With parameter 32 and parameter 35 the default behaviour can be changed!
10.8.1 ASC-W1 Mode: Reader in operation mode and sensor triggered reading Picture 1: Successful reading with instant host confirmation (Feature activated !) HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 86 WE GENERATE SOLUTIONS Customer manual LFM 32x WipRack RFID Picture 2: Successful reading with missing host confirmation (Feature activated !) Picture 3: Unsuccessful reading with instant host confirmation (Feature activated !) HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 87 WE GENERATE SOLUTIONS Customer manual LFM 32x WipRack RFID Picture 4: Unsuccessful reading with missing host confirmation (Feature activated !) HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 88 WE GENERATE SOLUTIONS Customer manual LFM 32x WipRack RFID 10.8.2 ASC-W1-Mode: Reader in operation mode and external triggered reading Picture 5: Successful external reading X (Feature activated !) Picture 6: Unsuccessful external reading X (Feature activated !) HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 89 WE GENERATE SOLUTIONS 10.9 ASCII table Customer manual LFM 32x WipRack RFID DEZ HEX CTRL Code DEZ HEX CTRL Code 21 22 23 24 25 26 27 28 29 30 31 15 16 17 18 19 1A 1B 1C 1D 1E 1F
^U
^V
^W
^X
^Y
^Z
^_ NAK SYN ETB CAN EM SUB ESC FS GS RS US 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 0 1 2 3 4 5 6 7 8 9 A B C D E F 10 11 12 13 14
^A
^B
^C
^D
^E
^F
^G
^H
^I
^J
^K
^L
^M
^N
^O
^P
^Q
^R
^S
^T NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT EF CR SOH SI DLE DC1 DC2 DC3 DC4 HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 90 WE GENERATE SOLUTIONS Customer manual LFM 32x WipRack RFID DEZ HEX CTRL DEZ HEX CTRL 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 BLANK
0 1 2 3 4 5 6 7 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 38 39 3A 3B 3C 3D 3E 3F 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 8 9
A B C D E F G H I J K L M N O HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 91 WE GENERATE SOLUTIONS Customer manual LFM 32x WipRack RFID DEZ HEX CTRL DEZ HEX CTRL 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F 60 61 62 63 64 65 66 67 P Q R S T U V W X Y Z
a b c d e f g 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F h i j k l m n o p q r s t u v w x y z
HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 92 WE GENERATE SOLUTIONS Customer manual LFM 32x WipRack RFID 11. Service and Troubleshooting 11.1 General information Follow the basic safety instructions in the chapter Safety instructions. The maintenance of the reading device and its components may only be performed by the manufacturer. Observe the instructions in this section when errors occur. Do not perform any further troubleshooting measures in addition to the described measures. In case of doubt concerning errors and handling them, contact the manufacturer. 11.2 Troubleshooting personnel Troubleshooting must only be performed by specially trained personnel. In case of doubts concerning the necessary qualifications, contact the manufacturer. The handling of device errors by untrained personnel as well as the incorrect handling of the device can result in personal injuries as well as damages to the reading device and/or connected devices. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 93 WE GENERATE SOLUTIONS 11.3 Safety instructions Customer manual LFM 32x WipRack RFID All components of the antenna oscillating circuit carry high voltage. Only use spare parts specified by the manufacturer. Unauthorised substitution of parts can result in fire, electric shock or other hazards. Electrostatic charges damage electronic components within the device. ESD protective measures must be applied prior to opening the unit. Carefully remove the housing covers to prevent damage. Do not operate the device when the housing is open. Never short circuit the fuse! This may result in fire or damages on the device. Only use fuses specified by the manufacturer. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 94 Customer manual LFM 32x WipRack RFID WE GENERATE SOLUTIONS 11.4 Error indications on the device Power-LED is off Check the power supply and the connecting cables!
Remove the power adapter. Open the case and check the fuse. Replace the fuse with a fuse specified by the manufacturer!
If the above measures do not resolve the problem, contact the manufacturer. 11.5 No communication with the reading device Check the interface connection cable for damage and correct connection!
Check the power LED is lit, and make sure that the status indicator does not indicate an error. Try to read in the reader with the HERMOS Device-Discoverer and check the device settings. If the above measures do not correct the error, please contact the manufacturer. HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 95 WE GENERATE SOLUTIONS 11.6 Software releases Customer manual LFM 32x WipRack RFID Release-date Version Description 17.08.2021 LFM4I1.8 (ASCII) 11.02.2022 LWR32I2.0 (ASCII) First Release for LFM4x WipRack Demo First Release for LFM32x WipRack with ASCII protocol HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 96 Customer manual LFM 32x WipRack RFID WE GENERATE SOLUTIONS 11.7 Customer service HERMOS AG Track & Trace RFID Division Gartenstrae 19 D-95490 Mistelgau Germany Phone Fax E-Mail URL:
+49 (0) 9279 991 - 0
+49 (0) 9279 991 - 100 rfid@hermos.com http://www.hermos.com/de/produkte/rfid/
HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 97 Customer manual LFM 32x WipRack RFID WE GENERATE SOLUTIONS 12. Disassembly and storage 12.1 Disassembly Remove the power supply Remove all cables Loosen and remove the mounting screws Remove the reading device from the installation area 12.2 Storage Store the reading device and its components in a clean and dry environment. Make sure that the power supply has been removed. Observe the required storage conditions specified in the technical data. 13. Transport and disposal 13.1 Transport Use a solid cardboard box for the transport. Use enough cushioning material to protect the device on all sides. 13.2 Disposal The device and its components are made of various materials. Disconnect the electronic components from the housing and dispose of them separately. Do not dispose of the unit in normal household waste. Dispose of the materials separately and according to the legal regulations of your country. Housing and attachments as plastic waste Electronic components, antennas and cables as electronic waste HERMOS AG Gartenstrae 19 95490 Mistelgau Phone: +49 9279 991 - 0 E-mail: rfid@hermos.com LFM 32x WipRack Rev1.0 back to the table of contents www.hermos.com 98
1 | Label and location | ID Label/Location Info | 51.91 KiB | February 08 2023 / February 27 2023 |
Ihr Zeichen:
Ihre Nachricht:
Unser Zeichen:
LD Mistelgau, 20.12.2022 Seite 1 von 1 HERMOS AG, Gartenstrae 19, 95490 Mistelgau Element Materials Technology 100 Frobisher Business Park Malvern Worcestershire WR14 1BX UK FCC ID: 2AP5OLFM-32X Subject: Permanent Label To Whom It May Concern:
We hereby declare that the device label with the above referenced FCC ID is permanently fixed on the LFM-32X. It will be printed on the PCB board. Contact person Position in the company Date of signatory Dngfelder Lothar Expert Hardware Development 2022-12-20 ___________________________ Signatory
(Signature of the applicant) Vorstand: Harald Khler, Florian Schwarz, Uwe Herrmannsdrfer Vorsitzender des Aufsichtsrates: Roland Fischer AG Bayreuth, HRB 3996, USt-IdNr: DE 236437317 Bankverbindungen:
Citibank, IBAN: DE97 5021 0900 0220 0030 43, BIC: CITIDEFFXXX HypoVereinsbank AG Bayreuth, IBAN: DE63 7732 0072 0329 8293 83, BIC: HYVEDEMM412 HERMOS AG Gartenstrae 19 95490 Mistelgau Tel. +49 (9279) 991-0 Fax +49 (9279) 991-100 e-mail: info@hermos.com http://www.hermos.com http://www.hermos.com
1 | Antenna Information | Operational Description | 181.81 KiB | February 08 2023 / February 27 2023 |
Antenna Information LFM_32x RFID Reader The used antenna is a inductive ferrit-antenna. Model Hermos Micro-antenna S404 L=110H (+-5%) Number of turns: 77 Size: Length 20mm, 6mm Mistelgau, 24.11.2022 Seite 1 von 1 PCB Layout with antenna L1 Vorstand: Harald Khler, Florian Schwarz, Uwe Herrmannsdrfer Vorsitzender des Aufsichtsrates: Roland Fischer AG Bayreuth, HRB 3996, USt-IdNr: DE 236437317 Bankverbindungen:
Citibank, IBAN: DE97 5021 0900 0220 0030 43, BIC: CITIDEFFXXX HypoVereinsbank AG Bayreuth, IBAN: DE63 7732 0072 0329 8293 83, BIC: HYVEDEMM412 HERMOS AG Gartenstrae 19 95490 Mistelgau Tel. +49 (9279) 991-0 Fax +49 (9279) 991-100 e-mail: info@hermos.com http://www.hermos.com
1 | Cover Letter | Cover Letter(s) | 109.00 KiB | February 08 2023 / February 27 2023 |
HERMOS AG, Gartenstrae 19, 95490 Mistelgau APPLICANT LETTER HEAD Letter of Agency Ihr Zeichen:
Ihre Nachricht:
Unser Zeichen:
LD Mistelgau, 15.11.2022 Seite 1 von 1 Date 2022-11-15 Element Materials Technology 100 Frobisher Business Park Malvern Worcestershire WR14 1BX UK To Whom It May Concern:
We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse ACT of 1988, U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002(b), to the application, is subject to denial of federal benefits, that includes FCC benefits. Thank you for your attention to this matter. Yours faithfully HERMOS AG ___________________________ Signatory
(Signature of the applicant) Vorstand: Harald Khler, Florian Schwarz, Uwe Herrmannsdrfer Vorsitzender des Aufsichtsrates: Roland Fischer AG Bayreuth, HRB 3996, USt-IdNr: DE 236437317 Bankverbindungen:
Citibank, IBAN: DE97 5021 0900 0220 0030 43, BIC: CITIDEFFXXX HypoVereinsbank AG Bayreuth, IBAN: DE63 7732 0072 0329 8293 83, BIC: HYVEDEMM412 HERMOS AG Gartenstrae 19 95490 Mistelgau Tel. +49 (9279) 991-0 Fax +49 (9279) 991-100 e-mail: info@hermos.com http://www.hermos.com http://www.hermos.com
1 | FCC Attestation Statement | Attestation Statements | 25.04 KiB | February 27 2023 |
Sample Attestation Statement -FCC Date: 2023-02-13 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, Maryland 21046 Re: Attestation regarding covered equipment and the Covered List FCC ID: 2AP5OLFM-32X To whom it may concern, Per 2.911(d)(5\(i), Hermos AG certifies that the equipment for which authorization is sought is not covered equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Per 2.911(d)(5)(ii), Hermos AG certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing covered equipment. Sincerely, LotharDingfelder Expert Hardware Development
1 | FCC ISED Agent Authorisation Letter | Cover Letter(s) | 56.07 KiB | February 08 2023 / February 27 2023 |
HERMOS AG, Gartenstrae 19, 95490 Mistelgau Element Materials Technology 100 Frobisher Business Park Malvern Worcestershire WR14 1BX UK Ihr Zeichen:
Ihre Nachricht:
Unser Zeichen:
LD Mistelgau, 28.10.2022 Seite 1 von 1 To Whom It May Concern:
Please be advised that we, HERMOS AG, authorize the following persons from Element Materials Technology Straubing GmbH:
Mr. Christian Kiermeier Ms. Jessica Httinger Mr. Rainer Heller Ms. Katja Frankl to handle the application of Type Approval Services for the following countries:
USA Unless future correspondence from us, please extend your full cooperation to Element Materials Technology Straubing GmbH regarding matters to 10 months after the signatory date of this authorization. Contact person Position in the company Date of signatory Dngfelder Lothar Expert Hardware Development 2022-10-25 ___________________________ Signatory
(Signature of the applicant) Vorstand: Harald Khler, Florian Schwarz, Uwe Herrmannsdrfer Vorsitzender des Aufsichtsrates: Roland Fischer AG Bayreuth, HRB 3996, USt-IdNr: DE 236437317 Bankverbindungen:
Citibank, IBAN: DE97 5021 0900 0220 0030 43, BIC: CITIDEFFXXX HypoVereinsbank AG Bayreuth, IBAN: DE63 7732 0072 0329 8293 83, BIC: HYVEDEMM412 HERMOS AG Gartenstrae 19 95490 Mistelgau Tel. +49 (9279) 991-0 Fax +49 (9279) 991-100 e-mail: info@hermos.com http://www.hermos.com http://www.hermos.com
1 | FCC Request for Confidentiality | Cover Letter(s) | 34.38 KiB | February 08 2023 / February 27 2023 |
HERMOS AG, Gartenstrae 19, 95490 Mistelgau Sample Request for Confidentiality Letter-FCC Ihr Zeichen:
Ihre Nachricht:
Unser Zeichen:
LD Mistelgau, 23.11.2022 Seite 1 von 1 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, Maryland 21046 Re: Request for confidentiality FCC ID: 2AP5OLFM-32X To whom it may concern, We hereby respectfully request that under the provision of 47 CFR 0.459 and 0.457(d) the documents listed below and attached with this application for certification be provided with confidential status. Schematics Operational Description Block Diagrams PCB Layout Parts List Any exhibit / information for which we have requested confidentiality, but which may not be accorded such treatment by the FCC, should be returned to us. The documents listed above contain trade secrets that are treated as confidential by us. Substantial competitive harm to us could result should they be made available to the public. Sincerely, Dngfelder Lothar Expert Hardware Development Vorstand: Harald Khler, Florian Schwarz, Uwe Herrmannsdrfer Vorsitzender des Aufsichtsrates: Roland Fischer AG Bayreuth, HRB 3996, USt-IdNr: DE 236437317 Bankverbindungen:
Citibank, IBAN: DE97 5021 0900 0220 0030 43, BIC: CITIDEFFXXX HypoVereinsbank AG Bayreuth, IBAN: DE63 7732 0072 0329 8293 83, BIC: HYVEDEMM412 HERMOS AG Gartenstrae 19 95490 Mistelgau Tel. +49 (9279) 991-0 Fax +49 (9279) 991-100 e-mail: info@hermos.com http://www.hermos.com
1 | FCC US Agent Attestation | Attestation Statements | 167.81 KiB | February 27 2023 |
Ihr Zeichen:
Ihre Nachricht:
Unser Zeichen:
LD Mistelgau, 14.02.2023 Seite 1 von 1 HERMOS AG, Gartenstrae 19, 95490 Mistelgau Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: February 14, 2023 Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID: 2AP5OLFM-32X HERMOS AG (the applicant) certifies that, as of the date of the filing of the application, TianHeng Consulting, LLC is our designated U.S. agent for service of process for the above referenced FCC ID. HERMOS AG accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. TianHeng Consulting, LLC accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Sincerely, Designated U.S. Agent Information:
Name: TianHeng Consulting, LLC Contact Person: Hualing Dong Address: 392 Andover Street, Wilmington, MA 01887, United States Tel.: +1 617-997-4010 Email: tianhengconsulting@gmail.com U.S. Agent Signature:
Applicant:
Company Name: HERMOS AG Grantee Code: 2AP5O Contact Name: Lothar Dngfelder Address: Gartenstr. 19 95490 Mistelgau - Germany Tel.: +49 9279991433 Email: Lothar.duengfelder@hermos.com Applicant Signature:
Vorstand: Harald Khler, Florian Schwarz, Uwe Herrmannsdrfer Vorsitzender des Aufsichtsrates: Roland Fischer AG Bayreuth, HRB 3996, USt-IdNr: DE 236437317 Bankverbindungen:
Citibank, IBAN: DE97 5021 0900 0220 0030 43, BIC: CITIDEFFXXX HypoVereinsbank AG Bayreuth, IBAN: DE63 7732 0072 0329 8293 83, BIC: HYVEDEMM412 HERMOS AG Gartenstrae 19 95490 Mistelgau Tel. +49 (9279) 991-0 Fax +49 (9279) 991-100 e-mail: info@hermos.com http://www.hermos.com http://www.hermos.com
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2023-02-27 | 0.1342 ~ 0.1342 | DCD - Part 15 Low Power Transmitter Below 1705 kHz | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2023-02-27
|
||||
1 | Applicant's complete, legal business name |
HERMOS AG
|
||||
1 | FCC Registration Number (FRN) |
0027610807
|
||||
1 | Physical Address |
Gartenstrasse 19
|
||||
1 |
Mistelgau, N/A
|
|||||
1 |
Germany
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
p******@element.com
|
||||
1 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
2AP5O
|
||||
1 | Equipment Product Code |
LFM-32X
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
L****** D********
|
||||
1 | Telephone Number |
00499******** Extension:
|
||||
1 | Fax Number |
00499********
|
||||
1 |
l******@hermos.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DCD - Part 15 Low Power Transmitter Below 1705 kHz | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | LF WIP-Regal 32x RFID kit | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | This device complies with the RF exposure requirements for mobile and portable devices. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Element Materials Technology Straubing GmbH
|
||||
1 | Name |
C******** K****
|
||||
1 | Telephone Number |
49-94********
|
||||
1 | Fax Number |
49-94********
|
||||
1 |
c******@element.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 0.13420000 | 0.13420000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC