all | frequencies |
|
exhibits | applications |
---|---|---|---|---|
manual |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User manual revised | Users Manual | 1.33 MiB | ||||
1 | Attestation Statements | |||||||
1 | Cover Letter(s) | |||||||
1 | External Photos | |||||||
1 | Internal Photos | |||||||
1 | ID Label/Location Info | |||||||
1 | ID Label/Location Info | |||||||
1 | Cover Letter(s) | |||||||
1 | Attestation Statements | |||||||
1 | RF Exposure Info | |||||||
1 | Test Setup Photos | |||||||
1 | Test Report | |||||||
1 | Test Report | |||||||
1 | Test Report | |||||||
1 | Test Report | |||||||
1 | Test Report |
1 | User manual revised | Users Manual | 1.33 MiB |
ProCurve Wireless Access Point 420 Installation and Getting Started Guide Copyright 2007 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. This document contains proprietary information, which is protected by copyright. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent of Hewlett-Packard. Publication Number 5991-6225 March 2007 Applicable Products ProCurve Wireless Access Point 420 NA ProCurve Wireless Access Point 420 WW
(J8130B)
(J8131B) Disclaimer HEWLETT-PACKARD COMPANY MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THIS MATERIAL, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Hewlett-Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. Hewlett-Packard assumes no responsibility for the use or reliability of its software on equipment that is not furnished by Hewlett-Packard. Warranty See the Customer Support/Warranty booklet included with the product. A copy of the specific warranty terms applicable to your Hewlett-
Packard products and replacement parts can be obtained from your HP Sales and Service Office or authorized dealer. Safety Before installing and operating these products, please read the Installation Precautions in chapter 2, Installing the Access Point 420, and the safety statements in appendix C, Safety and Regulatory Statements. Hewlett-Packard Company 8000 Foothills Boulevard, m/s 5552 Roseville, California 95747-5552 http://www.procurve.com Contents 1 Introducing the ProCurve Wireless Access Point 420 Top of the Access Point . 1-3 LEDs . 1-4 Back of the Access Point . 1-5 Antennas . 1-5 Console Port . 1-6 Network Port . 1-6 Power Connector . 1-6 Reset Button . 1-7 Access Point Features . 1-8 2 Installing the Access Point 420 Included Parts . 2-1 Installation Procedures . 2-2 Summary . 2-2 Installation Precautions: . 2-3 1. Prepare the Installation Site . 2-4 2. Verify the Access Point Passes the Self Test . 2-5 LED Behavior: . 2-6 3. Mount the Access Point . 2-7 Wall Mounting . 2-7 Horizontal Surface Mounting . 2-9 4. Connect the Access Point to a Power Source . 2-9 5. Connect the Network Cable . 2-10 Using the RJ-45 Connectors . 2-10 6. Position the Antennas on the Access Point . 2-10 7. (Optional) Connect a Console to the Access Point 420 . 2-11 Terminal Configuration . 2-11 Direct Console Access . 2-12 Sample Network Topologies . 2-14 Ad Hoc Wireless LAN (no access point) . 2-14 i Infrastructure Wireless LAN . 2-15 Infrastructure Wireless LAN for Roaming Wireless PCs . 2-16 3 Getting Started With Access Point Configuration Recommended Minimal Configuration . 3-1 Using the Command Line Interface . 3-2 To Set the Manager User Name and Password . 3-2 To Set the Access Points IP Address . 3-3 To Set the Access Points Country Code . 3-4 To Configure Radio Settings . 3-5 Where to Go From Here . 3-8 Using the IP Address for Remote Access Point Management . 3-9 Starting a Telnet Session . 3-9 Starting an SSH Session . 3-10 Starting a Web Browser Session . 3-10 4 Using an External Antenna with the Access Point 420 External Antenna Options . 4-2 Installation Procedures . 4-3 1. Plan the Installation . 4-3 2. Mount the Antenna . 4-4 3. Connect Pigtail Cables to the Access Point . 4-4 4. Configure the Antenna Mode and Transmit Power Control Limits 4-6 Setting the Antenna Mode Using the CLI . 4-8 Setting the Antenna Mode Using the Web Interface . 4-9 Setting Transmit Power Limits Using the CLI . 4-9 Setting Transmit Power Limits Using the Web Inteface . 4-10 5 Troubleshooting Basic Troubleshooting Tips . 5-1 Diagnosing with the LEDs . 5-3 Proactive Networking . 5-5 Hardware Diagnostic Tests . 5-6 Testing the Access Point by Resetting It . 5-6 Checking the Access Points LEDs . 5-6 Checking Event Messages . 5-6 ii Testing Twisted-Pair Cabling . 5-7 Testing Access Point-to-Device Network Communications . 5-7 Testing End-to-End Network Communications . 5-7 Restoring the Factory Default Configuration . 5-8 Downloading New Access Point Software . 5-10 HP Customer Support Services . 5-10 Before Calling Support . 5-10 A Specifications Physical . A-1 Electrical . A-1 Environmental . A-1 Connectors . A-2 Safety . A-2 EMC Compliance (Class B) . A-2 Telecom . A-2 Immunity . A-2 Wireless . A-3 Receiver Sensitivity . A-3 B Access Point Port and Network Cables Access Point Ports . B-1 Twisted-Pair Cables . B-1 Twisted-Pair Cable/Connector Pin-Outs . B-2 Straight-Through Twisted-Pair Cable for 10 Mbps or 100 Mbps Network Connections . B-3 Cable Diagram . B-3 Pin Assignments . B-3 Crossover Twisted-Pair Cable for 10 Mbps or 100 Mbps Network Connection . B-4 Cable Diagram . B-4 Pin Assignments . B-4 iii C Safety and EMC Regulatory Statements Safety Information . C-1 EMC Regulatory Statements . C-9 D Recycle Statements Waste Electrical and Electronic Equipment (WEEE) Statements D-1 Index iv W i r e l e s s A c c e s s P o i n t 4 2 0 I n t r o d u c i n g t h e P r o C u r v e 1 Introducing the ProCurve Wireless Access Point 420 The ProCurve Wireless Access Point 420 is a wireless repeater that seamlessly integrates with existing wired networks to support connectivity for mobile users or wireless workstations. This solution offers fast, reliable wireless connectivity with considerable cost savings over wired LANs. Just install enough wireless access points to cover your network area, plug wireless cards into your notebooks or install wireless adapters into your desktops, and start networking. ProCurve Wireless Access Point 420 NA (J8130B ProCurve Wireless Access Point 420 WW (J8131B) Link/Activity 10/100-TX Wireless Power hpprocurve wireless access point 420 1-1 e v r u C o r P e h t g n i c u d o r t n I 0 2 4 t n i o P s s e c c A s s e l e r i W Introducing the ProCurve Wireless Access Point 420 Throughout this manual, this access point will be abbreviated as the Access Point 420. The Access Point 420 has one 10/100Base-TX RJ-45 port. This port also supports Power over Ethernet (PoE) based on the IEEE 802.3af standard. The access point supports wireless connectivity at speeds up to 54 Mbps based on the IEEE 802.11g standard. This access point is designed to be used primarily for connecting wireless clients to an enterprise network. This access point allows wireless clients to connect directly to each other, or to connect to other computers or network resources located on the wired network. This chapter describes your Access Point 420 including:
Top and back of the access point Access point features 1-2 Introducing the ProCurve Wireless Access Point 420 Top of the Access Point Top of the Access Point ProCurve Wireless Access Point 420 Antennas W i r e l e s s A c c e s s P o i n t 4 2 0 I n t r o d u c i n g t h e P r o C u r v e Power, 10/100-TX Link, and Wireless Link LEDs hp procurve access point wireless 420 Link/Activity Power 10/100-TX Wireless Link/Activity Power 10/100-TX Wireless Indicator Panel hp procurve access point wireless 420 Power LED Ethernet LED Wireless LED 1-3 e v r u C o r P e h t g n i c u d o r t n I 0 2 4 t n i o P s s e c c A s s e l e r i W Introducing the ProCurve Wireless Access Point 420 Top of the Access Point Access Point LEDs Power
(green) LEDs Table 1-1. Access Point LEDs State Meaning On Off Blinking*
Blinking*
(prolonged) The access point is receiving power. The access point is NOT receiving power. The access point is undergoing self test or downloading software. The self test and initialization are in progress after you have power cycled or reset the access point. The access point is not operational until this LED stops blinking. A component of the access point has failed its self test. 10/100-TX On (green) The RJ-45 port is enabled and receiving a link indication from a 100 Mbps device. On (amber) The RJ-45 port is enabled and receiving a link indication from a 10 Mbps device. Off The RJ-45 port has no active network cable connected, or is not receiving a signal. Otherwise, the port may have been disabled through the access point console, or the web browser interface. Blinking*
The RJ-45 port is transmitting or receiving traffic. Wireless On Off The wireless interface is enabled and receiving a link indication from a wireless client The wireless interface is not receiving a signal. Otherwise, the wireless interface may have been disabled through the access point console, or the web browser interface. Blinking*
The wireless interface is transmitting or receiving traffic.
* The blinking behavior is an on/off cycle once every 1.6 seconds, approximately. 1-4 W i r e l e s s A c c e s s P o i n t 4 2 0 I n t r o d u c i n g t h e P r o C u r v e Introducing the ProCurve Wireless Access Point 420 Back of the Access Point Back of the Access Point ProCurve Wireless Access Point 420 Antennas hp procurve wireless AP 420 na J8130B Console 10/100Base-TX 3.3V 4A Reset Console port DC power connector Lock Network port 10/100Base-TX RJ-45 port and PoE input Reset button Antennas The access point includes diversity antennas for wireless communications. These antennas are detachable and can be replaced by various external antenna options. For further information, see chapter 4, Using an External Antenna with the Access Point 420. Lock The access point includes a Kensington security slot on the rear panel, marked with the lock symbol (
access point by wrapping the Kensington security cable (not provided) around an unmovable object, inserting the lock into the slot, and turning the key.
). You can prevent unauthorized removal of the 1-5 e v r u C o r P e h t g n i c u d o r t n I 0 2 4 t n i o P s s e c c A s s e l e r i W Introducing the ProCurve Wireless Access Point 420 Back of the Access Point Console Port This port connects a console to the access point using a serial cable. This connection is described under Connect a Console to the Access Point in chapter 2, Installing the Access Point 420. The console can be a PC or workstation running a VT-100 terminal emulator, or a VT-100 terminal. Network Port The access point includes one 10/100Base-TX port. This port uses MDI
(i.e., internal straight-through) pin configuration. You can therefore use straight-through twisted-pair cable to connect this port to most network interconnection devices such as a switch or router that provide MDI-X ports. However, if you need to connect the access point to a workstation or other device that only has MDI ports, then use crossover twisted-pair cable. Ports on most ProCurve Networking switches have the HP Auto MDIX feature, which means that you can use either straight-through or crossover twisted-pair cables to connect the access point to these switches. Refer to the following section for information on supplying power to the access point through its RJ-45 port from a network device, such as a switch, that provides Power over Ethernet (PoE). Power Connector The Access Point 420 does not have a power switch; it is powered on when connected to the AC power adapter, and the power adapter is connected to an active AC power source. The access point's power adapter automatically adjusts to any voltage between 100--240 volts and either 50 or 60 Hz. There are no voltage range settings required. C a u t i o n Use only the AC power adapter supplied with the access point. Use of other adapters, including adapters that came with other ProCurve Networking products, may result in damage to the equipment. The access point may also receive Power over Ethernet (PoE) from a switch or other network device that supplies power over the network cable based on the IEEE 802.3af standard. Note that if the access point is connected to a PoE source device and also connected to a local power source through the AC power adapter, PoE will be disabled. 1-6 W i r e l e s s A c c e s s P o i n t 4 2 0 I n t r o d u c i n g t h e P r o C u r v e Introducing the ProCurve Wireless Access Point 420 Back of the Access Point Reset Button This button is used to reset the hardware or restore the factory defaults:
To Reset the Access Point While it is Powered On This action clears any temporary error conditions that may have occurred and executes the access point self test. To Restore Factory Default Configuration When the Reset button is pressed for more than five seconds, any configuration changes you may have made through the access point console or the web browser interface are removed, and the factory default configuration is restored to the access point. For the specific method to restore the factory default configuration, see Restoring the Factory Default Configuration in chapter 5, Troubleshooting of this manual. N o t e The Reset button and console port can be disabled by the access points software. For more information, see the Management and Configuration Guide, which is on the Documentation CD-ROM that came with your access point. 1-7 e v r u C o r P e h t g n i c u d o r t n I 0 2 4 t n i o P s s e c c A s s e l e r i W Introducing the ProCurve Wireless Access Point 420 Access Point Features Access Point Features The wireless features of the Access Point 420 include:
supports up to eight Service Set IDentifier (SSID) interfaces security and VLAN settings per SSID interface supports up to 128 wireless clients IEEE 802.11g Compliant interoperable with multiple vendors precise control over signal transmission power and data rate advanced security through 64/128/152-bit WEP encryption, Wi-Fi Protected Access (WPA and WPA2), IEEE 802.1X, remote authentication via a RADIUS server, and MAC address filtering features to protect your sensitive data and authenticate only authorized users to your network remote logging of system messages time synchronization via SNTP server for message logs neighbor access point detection Spectralink Voice Priority support auto channel selection simplifies deployment by testing all available channels and selecting the best channel based on signal-to-noise ratio international country configuration select the appropriate country and the access point automatically configures radio operation to match regu-
latory requirements (model J8131A only) The other basic features of the Access Point 420 include:
one 10/100Base-TX RJ-45 port supports Power over Ethernet based on the IEEE 802.3af standard full-duplex operation for the 10/100 RJ-45 port easy management of the access point through several available interfaces:
console interfacea full featured, easy to use, VT-100 terminal interface that is especially good for out-of-band access point manage-
ment and for Telnet or Secure Shell access to the access point
web browser interfacean easy to use built-in graphical interface that can be accessed from common web browsers (includes support for secure HTTP connections) SNMPa network management application such as ProCurve Manager can manage the access point via the Simple Network Management Protocol (SNMP) from a network management station
(supports SNMP versions 1, 2c, and 3)
1-8 W i r e l e s s A c c e s s P o i n t 4 2 0 I n t r o d u c i n g t h e P r o C u r v e Introducing the ProCurve Wireless Access Point 420 Access Point Features support for up to 64 IEEE 802.1Q-compliant VLANs (as specified for each client in the RADIUS server) so that wireless clients can join the appro-
priate logical grouping for the network users needs RADIUS Accounting for logging user activity on the network support for many advanced features to enhance network performance for a description, see the Management and Configuration Guide, which is on the Documentation CD-ROM that is included with your access point. download of new access point software for product enhancements or software updates upload and download of access point configuration files in a binary or readable text format dual flash images enables auto-recovery upon unsuccessful download 1-9 This page is intentionally unused. Installing the Access Point 420 2 The Access Point 420 is easy to install. It comes with an accessory kit that includes a bracket for mounting the access point on a wall. The bracket is designed to allow mounting the access point in a variety of locations and orientations. This chapter shows you how to install your Access Point 420. Included Parts The Access Point 420 has the following components shipped with it:
ProCurve Wireless Access Point 420 Installation and Getting Started Guide (5991-6225), this manual ProCurve Product Documentation CD-ROM
(contains PDF file copies of the documentation for the Access Point 420, including the Management and Configuration Guide) Customer Support/Warranty booklet Accessory kit (5069-5700)
four 5/8-inch number 12 wood screws to attach the access point to a wall four plastic wall plugs for mounting on a brick or concrete wall four rubber feet Antenna (5092-0723) Mounting bracket (5092-0711) AC power adapter (5092-0728) AC power cord, one of the following:
United States/Canada/Mexico Continental Europe United Kingdom/Hong Kong/Singapore Australia/New Zealand Japan China Denmark Switzerland 8120-0740 8121-0731 8121-0739 8121-0730 8121-0736 8121-0742 8121-0733 8121-0738 2-1 A c c e s s P o i n t 4 2 0 I n s t a l l i n g t h e e h t g n i l l a t s n I 0 2 4 t n i o P s s e c c A Installing the Access Point 420 Installation Procedures Installation Procedures Summary Follow these easy steps to install your access point. The rest of this chapter provides details on these steps. 1. Prepare the installation site (page 2-4). Make sure that the physical environment into which you will be installing the access point is properly prepared, including having the correct network cabling ready to connect to the access point and having an appropriate location for the access point. Please see page 2-2 for some installation precautions. 2. Verify that the access point passes self test (page 2-5). This is a simple process of plugging the access point into a power source, or connecting it to a switch that provides Power over Ethernet, and observing that the LEDs on the access points top panel indicate correct access point operation. 3. Mount the access point (page 2-7). The Access Point 420 can be mounted on a wall, or on a horizontal surface. 4. Connect power to the access point (page 2-9). Once the access point is mounted, plug it into a nearby main power source, or connect it to a switch that provides Power over Ethernet. 5. Connect to the network (page 2-10). Using the appropriate network cable, connect the access point to a network connection point, such as a switch. The network connection can also be used to provide power to the access point through its PoE feature. 6. Position the antennas on the access point (page 2-10). Position each antenna along a different axis to enhance signal coverage. 7. Connect a console to the access point (optionalpage 2-11). You may wish to modify the access points configuration, for example, to configure an IP address so it can be managed using a web browser or through a Telnet session. Configuration changes can be made easily by using a console cable to connect a PC to the access points console port. At this point, your access point is fully installed. See the rest of this chapter if you need more detailed information on any of these installation steps. 2-2 Installing the Access Point 420 Installation Procedures Installation Precautions:
Follow these precautions when installing your Access Point 420:
C a u t i o n s Make sure that the power source circuits are properly grounded, then use the power adapter supplied with the access point to connect it to the power source. You can alternatively power the access point through a network connec-
tion to a switch or other network connection device that provides Power over Ethernet. However, note that if the access point is connected to a power source using its AC power adapter, Power over Ethernet is disabled. Use only the AC power adapter supplied with the access point. Use of other adapters, including adapters that came with other ProCurve Networking products, may result in damage to the equipment. When using the acess points AC power adapter, note that the AC outlet should be near the access point and should be easily accessible in case the access point must be powered off. Ensure that the access point does not overload the power circuits, wiring, and over-current protection. To determine the possibility of overloading the supply circuits, add together the ampere ratings of all devices installed on the same circuit as the access point and compare the total with the rating limit for the circuit. The maximum ampere ratings are usually printed on devices near the AC power connectors. Do not install the access point in an environment where the operating ambient temperature might exceed 40 C (104 F). Make sure the air flow around the sides of the access point is not restricted. 2-3 A c c e s s P o i n t 4 2 0 I n s t a l l i n g t h e e h t g n i l l a t s n I 0 2 4 t n i o P s s e c c A Installing the Access Point 420 Installation Procedures 1. Prepare the Installation Site Cabling Infrastructure - Ensure that the cabling infrastructure meets the necessary network specifications. See the following table for cable types and lengths, and see appendix B, Access Point Port and Network Cables for more information. Table 2-1. Summary of Cable Types to Use With the Access Point Port Type Cable Type Length Limits 10/100Base-TX 10 Mbps operation:
100 meters Twisted-Pair Cables Category 3, 4, or 5, 100-ohm unshielded twisted-pair (UTP)
100 Mbps operation:
Category 5, 100-ohm UTP or shielded twisted-pair (STP) cable. Note: Since the 10Base-T operation is through the 10/100Base-TX port on the access point, if you ever want to upgrade the ports on other devices to 100Base-TX, it would be best to cable the 10/100Base-TX port on the access point initially with category 5 cable. The 10/100-Base-TX port on the Access Point 420 uses an MDI pin configuration, which requires you to use straight-through cable when connecting to another device that has an MDI-X port, or crossover cable when connecting to a device that has an MDI port. However, if the device to which you are connecting supports auto-
MDIX, then you can use either a straight-
through or crossover cable. Installation Location - Before installing the access point, plan its loca-
tion and orientation relative to other devices and equipment:
Try to place the access point in the center of your wireless network. Normally, the higher you place the antenna, the better the perfor-
mance. You may need to reposition the access point after testing the signal strength on several wireless clients to ensure that the access points location provides optimal reception throughout your office.
At the back of the access point, leave at least 7.6 cm (3 inches) of space for the twisted-pair cabling and the power cord.
On the sides of the access point, leave at least 7.6 cm (3 inches) for cooling. 2-4 Installing the Access Point 420 Installation Procedures 2. Verify the Access Point Passes the Self Test Before mounting the access point in its network location, you should first verify that it is working properly by plugging it into a power source, or connecting it to a switch that provides Power over Ethernet, and verifying that it passes its self test. 1. Connect a network cable from a PoE source device (such as a switch) to the RJ-45 port on the back of the access point, or connect the supplied power adapter to the power connector on the back of the access point, and then into a properly grounded electrical outlet. hp procurve wireless AP 420 na J8130B Console 10/100Base-TX Reset 3.3V 4A Connect network cable to PoE switch Or connect power adapter to the power connector N o t e The Access Point 420 does not have a power switch. It is powered on when the power adapter is connected to the access point and to a power source, or when a network cable is connected to the access point and to a network device that provides Power over Ethernet. For safety, when connecting to an elec-
trical outlet, the power outlet should be located near the access point. Use only the AC power adapter supplied with the access point. Use of other adapters, including adapters that came with other ProCurve Networking products, may result in damage to the equipment. 2-5 A c c e s s P o i n t 4 2 0 I n s t a l l i n g t h e e h t g n i l l a t s n I 0 2 4 t n i o P s s e c c A Installing the Access Point 420 Installation Procedures 2. Check the LEDs on the access point as described below. hp procurve wireless access point 420 Link/Activity Power 10/100-TX Wireless Power LED Ethernet LED Wireless LED When the access point is powered on, it performs its diagnostic self test. The self test takes approximately 50 seconds to complete. LED Behavior:
During the self test:
The 10/100Base-TX and Wireless LEDs go off and then may come on again during phases of the self test. For the duration of the self test, the Power LED blinks. When the self test completes successfully:
The Power LED remains on. The 10/100Base-TX and Wireless LEDs on the top of the access point go into their normal operational mode:
If the ports are connected to active network devices, the LEDs should be on. If the ports are not connected to active network devices, the LEDs stay off. If the LED display is different than what is described above, especially if the Power LED does not stop blinking, the self test has not completed correctly. Refer to chapter 5, Troubleshooting for diagnostic help. 2-6 Installing the Access Point 420 Installation Procedures 3. Mount the Access Point After you have verified that the access point passes the self test, you are ready to mount the access point in a stable location. The Access Point 420 can be mounted in these ways:
on a wall on a horizontal surface Wall Mounting You can mount the access point on a wall as shown in the illustrations on the next page. C a u t i o n The access point should be mounted only to a wall or wood surface that is at least 1/2-inch plywood or its equivalent. 1. Position the mounting bracket on the wall, and mark the holes. The orientation shown in the following figure is the most secure position for mounting the access point. Do not mount the access point with the retaining latches pointing down. 2. To mount the access point on a plastered brick or concrete wall, first drill four holes 22 mm deep and 3.5 mm in diameter, and press the four included wall plugs firmly into the drilled holes until they are flush with the surface of the wall. 3. Set the four 5/8-inch number 12 wood screws in the holes, leaving about 3 mm (0.12 in.) clearance from the wall. 4. Position the mounting bracket over the wall screws, slide the bracket onto the screws, and then tighten down the screws. 5. There are two alignment slots along the lower edge of the mounting bracket as shown in the following figures. Match these slots up with the protrusions on the units plastic cover. This makes it easy to get the metal fingers on the bracket aligned with the three protruding slots in the bottom of the access point. 6. Slide the access point down onto the bracket so that the three metal fingers on the bracket enter the three protruding slots on the bottom of the access point. The two retaining latches will slip into place over the back edge of the access point. 7. To prevent unauthorized removal of the access point, you can use a Kensington Slim MicroSaver security cable (not included) to attach the access point to an immovable object. 2-7 A c c e s s P o i n t 4 2 0 I n s t a l l i n g t h e e h t g n i l l a t s n I 0 2 4 t n i o P s s e c c A Installing the Access Point 420 Installation Procedures N o t e If mounting the access point in an air conditioning or heating duct, leave the cover on to aid in mounting the unit on the bracket as described in the preceding steps. The units plastic cover should then be removed for safety reasons. Mounting the Bracket on a Wall 5/8-inch wood screws Sliding the Access Point onto the Bracket Retaining latches Mounting slots Mounting points Alignment tabs Alignment slots 2-8 Installing the Access Point 420 Installation Procedures Horizontal Surface Mounting Place the access point on a table or other horizontal surface. The access point accessory kit provides rubber feet that can be used to help keep the access point from sliding on the surface. Attach the rubber feet to the four corners on the bottom of the access point within the embossed lines. Use a sturdy surface in an uncluttered area. You may want to secure the networking cable and access points power cord to the table leg or other part of the surface structure to help prevent tripping over the cords. C a u t i o n Make sure the air flow is not restricted around the sides of the access point. 4. Connect the Access Point to a Power Source 1. Plug the included power adapter into the access points power connector and into a nearby AC power source. Or, alternatively, connect the Ethernet port on the access point to a switch or other network device that provides Power over Ethernet. 2. Re-check the LEDs during self test. See LED Behavior on page 2-6. 2-9 A c c e s s P o i n t 4 2 0 I n s t a l l i n g t h e e h t g n i l l a t s n I 0 2 4 t n i o P s s e c c A Installing the Access Point 420 Installation Procedures 5. Connect the Network Cable Connect the network cable, described under Cabling Infrastructure
(page 2-4), from the network device or your patch panel to the RJ-45 port on the access point. Using the RJ-45 Connectors To connect:
Push the RJ-45 plug into the RJ-45 port until the tab on the plug clicks into place. When power is on for the access point and for the connected device, the 10/100Base-TX link LED should light to confirm a powered-on device (for example, a switch) is at the other end of the cable. If the 10/100Base-TX link LED does not go on when the network cable is connected to the port, see Diag-
nosing with the LEDs in chapter 5, Troubleshooting. RJ-45 connector Cable:
Category 3, 4, or 5 for 10 Mbps ports (UTP)
Category 5 or better for 100 Mbps ports (STP) Maximum distance: 100 meters To disconnect:
Press the small tab on the plug and pull the plug out of the port. 6. Position the Antennas on the Access Point The antennas emit and receive signals along a toroidal planeand thus provide more effective coverage when positioned along different axes. For example, you might position the antennas around 45 to 90 degrees from each other. The access point compares the strength of an incoming signal on both antennas, and uses the antenna receiving the stronger signal to communicate with a wireless client. Note that both antennas are used to transmit, but never at the same time. The access points antennas can also be replaced by various external antenna options that offer extended radio range and specific radio coverge patterns. For further information, see chapter 4, Using an External Antenna with the Access Point 420. 2-10 Installing the Access Point 420 Installation Procedures 7. (Optional) Connect a Console to the Access Point 420 The Access Point 420 has a full-featured, easy to use console interface for performing access point management tasks, including the following:
modify the access points configuration to optimize access point perfor-
mance, enhance network traffic control, and improve network security download new software to the access point set a Manager password to control access to the access point from the console, web browser interface, and network management stations The console can be accessed through these methods:
Out-of-Band: Use a serial cable for connecting a PC or VT-100 terminal to be used as a console directly to the access point. In-Band: Access the console using Telnet or Secure Shell (SSH) from a PC on the network, and a VT-100 terminal emulator. This method requires that you first configure the access point with an IP address and subnet mask by using either out-of-band console access or through DHCP. For more information on IP addressing and on starting a Telnet or SSH session, see chapter 3, Getting Started With Access Point Configuration, and the Management and Configuration Guide, which is on the Documentation CD-ROM that came with your access point. The Access Point 420 can simultaneously support one out-of-band console session through the Console Port and four in-band Telnet or SSH console sessions. N o t e For information on using the Web browser interface to configure the access point, refer to the Management and Configuration Guide. Terminal Configuration To connect a console to the access point, configure the PC terminal emulator as a DEC VT-100 (ANSI) terminal or use a VT-100 terminal, and configure either one to operate with these settings:
9600 baud 8 data bits, 1 stop bit, no parity, and flow control set to None For the Windows Terminal program, also disable (uncheck) the Use Function, Arrow, and Ctrl Keys for Windows option For the Hilgraeve HyperTerminal program, select the Terminal keys option for the Function, arrow, and ctrl keys act as parameter You can only attach to the console using these configuration settings. 2-11 A c c e s s P o i n t 4 2 0 I n s t a l l i n g t h e e h t g n i l l a t s n I 0 2 4 t n i o P s s e c c A Installing the Access Point 420 Installation Procedures Direct Console Access To connect a console to the access point, follow these steps:
1. Connect the PC or terminal to the access points Console port using a DB-9 female-to-
female serial cable. (If your PC or terminal has a 25-pin serial connector, first attach a 9-pin to 25-pin straight-
through adapter at one end of the console cable.) The Console cable is described below. A null-
modem cable or a ProCurve Networking serial cable, part number 5184-1894 (shipped with many ProCurve switches), may be used. Console port Console cable
(not supplied) PC running a terminal emulator program, or a VT-100 terminal Access Point 420 serial port pin and signalling details Access Point 420 Pin Assignment Pin Number Access Point Signal (DTE) 1 6 DB-9 male 5 9 1 2 3 4 5 6 7 8 9 Reserved RXD (input) TXD (output) Reserved GND Reserved RTS (output) CTS (input) Reserved Connection to PC serial ports also requires a crossover (null-modem) cable with a female DB-9 connector on both ends. Terminal connections will vary, requiring either a DB-9 or DB-25 connector, male or female. Serial cable options between a ProCurve Wireless Access Point 420 and a PC terminal are shown in the following table. 2-12 A c c e s s P o i n t 4 2 0 I n s t a l l i n g t h e Installing the Access Point 420 Installation Procedures Note: As indicated in the following table, some of the wires should not be connected. If you do connect the wires that are labeled Reserved, you might get unexpected results with some terminals. Serial interface signal directions DB-9 (DTE) Access Point 420 DB9 (DTE) Terminal or PC DB-9 (DTE) Access Point 420 DB-25 (DTE) Terminal or PC 1 2 3 4 5 6 7 8 9 Reserved Reserved GND Reserved Reserved 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 Reserved Reserved GND Reserved Reserved 8 3 2 20 7 6 4 5 22 2. Turn on the terminal or PCs power and, if using a PC, start the PC terminal program. 3. Enter admin at the Username: prompt, and press the [Enter] key at the Password prompt. You will then see the access point console command
(CLI) prompt, for example:
HP ProCurve Wireless Access Point 420#
If you want to continue with console management of the access point at this time, see chapter 3, Getting Started With Access Point Configuration for some basic configuration steps. For more detailed information, refer to the Management and Configuration Guide, which is on the Documentation CD-ROM that came with your access point. 2-13 e h t g n i l l a t s n I 0 2 4 t n i o P s s e c c A Installing the Access Point 420 Sample Network Topologies Sample Network Topologies This section shows you a few sample network topologies in which the Access Point 420 is implemented. The wireless solution supports a stand-
alone wireless network configuration as well as an integrated configuration with wired Ethernet LANs. Wireless network cards, adapters, and access points can be configured as:
ad hoc for departmental or SOHO LANs infrastructure for wireless LANs infrastructure wireless LAN for roaming wireless PCs For more topology information, see the ProCurve Networking World Wide Web site, http://www.procurve.com. Ad Hoc Wireless LAN (no access point) Notebook with Wireless USB Adapter Ad Hoc Network with No Access Point Notebook with Wireless PC Card PC with Wireless PCI Adapter An ad-hoc wireless LAN consists of a group of computers, each equipped with a wireless adapter, connected via radio signals as an independent wireless LAN. Computers in a specific ad-hoc wireless LAN must therefore be config-
ured to the same radio channel. An ad-hoc wireless LAN can be used for a branch office or SOHO operation. 2-14 Infrastructure Wireless LAN Installing the Access Point 420 Sample Network Topologies Desktop PC File Server Wired LAN Extension to Wireless Adapters Notebook with wireless PC Card Adapter Switch Access Point 420 A c c e s s P o i n t 4 2 0 I n s t a l l i n g t h e PC with wireless PCI Adapter The Access Point 420 is designed to provide access to a wired LAN for wireless clients. An integrated wired/wireless LAN is called an Infrastructure configu-
ration. A Basic Service Set (BSS) consists of a group of wireless PC users, and an access point that is directly connected to the wired LAN. Each wireless PC in this BSS can talk to any computer in its wireless group, or access other computers or network resources in the wired LAN infrastructure via the access point. The infrastructure configuration not only extends the accessibility of wireless PCs to the wired LAN, but also increases the effective wireless transmission range for wireless PCs by passing their signal through one or more access points. 2-15 e h t g n i l l a t s n I 0 2 4 t n i o P s s e c c A Installing the Access Point 420 Sample Network Topologies Infrastructure Wireless LAN for Roaming Wireless PCs File Server Seamless Roaming for Wireless Clients Desktop PC Switch Wireless Client Switch Wireless Client Access Point 420
<BSS2>
Access Point 420
<BSS1>
<ESS>
Wireless Client The Basic Service Set (BSS) defines the communications domain for each access point and its associated wireless clients. The BSS ID is a 48-bit binary number based on the access points wireless MAC address, and is set automat-
ically and transparently as clients associate with the access point. The BSS ID is used in frames sent between the access point and its clients to identify traffic in the service area. The BSS ID is only set by the access point, never by its clients. The clients only need to set the Service Set Identifier (SSID) that identifies the service set provided by one or more access points. The SSID can be manually configured by the clients, can be detected in an access points beacon, or can be obtained by querying for the identity of the nearest access point. For clients that do not need to roam, set the SSID for the wireless card to that used by the access point to which you want to connect. 2-16 A c c e s s P o i n t 4 2 0 I n s t a l l i n g t h e Installing the Access Point 420 Sample Network Topologies A wireless infrastructure can also support roaming for mobile workers. More than one access point can be configured to create an Extended Service Set
(ESS). By placing the access points so that a continuous coverage area is created, wireless users within this ESS can roam freely. All wireless network cards, adapters, and access points within a specific ESS must be configured with the same SSID. 2-17 This page is intentionally unused. Getting Started With Access Point Configuration 3 This chapter is a guide for using the access points console to quickly assign an Internet Protocol (IP) address and subnet mask to the access point, set a manager password, and, optionally, configure other basic features. For more information on using the access points console and the Web browser interface, please see the Management and Configuration Guide, which is on the Documentation CD-ROM that came with your access point. Recommended Minimal Configuration In the factory default configuration, the access point is configured as a DHCP client. If the access point fails to obtain an IP address from the DHCP server, its IP address defaults to 192.168.1.1. If this address is not compatible with your network, then the access point can only be managed through a direct console connection. To manage the access point through in-band (networked) access, you should configure the access point with an IP address and subnet mask compatible with your network. Also, you should configure a Manager password to control access to the console and web browser interface. Other parameters can be left at their default settings or you can configure them with values you enter. The country code for the ProCurve Wireless Access Point 420 NA (J8130B) sold in the United States and Canada is fixed in the firmware and cannot be changed. This means that only radio channels 1-11 are available for this model. The country code for the ProCurve Wireless Access Point 420 WW (J8131B) sold in other countries is not set, and must be configured before you can enable radio communications for the access point. Setting the country code enables only those radio channels permitted for wireless networks in the specified country. Please refer toTo Set the Access Points Country Code on page 3-4 for information on setting the country code. Note that once you have set the country code, it can only be changed by restoring the factory default settings as described under Restoring the Factory Default Configuration on page 5-8. 3-1 C a u t i o n P o i n t C o n f i g u r a t i o n G e t t i n g S t a r t e d W i t h A c c e s s Getting Started With Access Point Configuration Many other features can be configured through the access points console interface to optimize the access points performance, to enhance your control of the network traffic, and to improve network security. Once an IP address has been configured on the access point, these features can be accessed more conveniently through a remote Telnet or Secure Shell (SSH) session, or through the access points Web browser interface. For more information on IP addressing, refer to Configuring IP Settings in the Management and Configuration Guide. By default, the access point is configured to acquire an IP address configura-
tion from a DHCP server. To use DHCP instead of the manual method described in this chapter, see Configuring IP Settings in the Management and Configuration Guide, which is on the Documentation CD-ROM that came with your access point. Using the Command Line Interface The quickest and easiest way to minimally configure the access point for management and password protection in your network is to use a direct console connection to the access point, start a console session, and access the command line interface (CLI). To Set the Manager User Name and Password Management access to the access points Web and CLI interface is controlled through user names and passwords. A Manager user name and password allows full read/write privileges for the Web and CLI. An Operator user name and password can also be configured. The Operator is restricted to read-only access. A maximum of only two users can be configured, one Manager and one Operator. 1. Using the method described in the preceding chapter, connect a terminal device to the access point, and press [Enter] to initiate the console connec-
tion. 2. Type admin for the default Manager user name. The default password is null, so just press [Enter] at the password prompt. The CLI prompt appears displaying the access points model number. Username: admin Password:
HP ProCurve Access Point 420#
N o t e 3-2 s s e c c A h t i W d e t r a t S g n i t t e G n o i t a r u g i f n o C t n i o P Getting Started With Access Point Configuration 3. Type configure to enter global configuration mode. HP ProCurve Access Point 420#configure Enter configuration commands, one per line. HP ProCurve Access Point 420(config)#
4. Type management to enter management configuration. HP ProCurve Access Point 420(config)management Enter management commands, one per line. HP ProCurve Access Point 420(config-mgmt)#
5. Type username-admin username to create a user name for the Manager, where username can consist of 3 to 16 alphanumeric characters and is case sensitive. HP ProCurve Access Point 420(config-mgmt)#username-admin steve HP ProCurve Access Point 420(config-mgmt)#
6. Type password-admin password to create a password for the Manager, where password can consist of up to 16 alphanumeric characters and is case sensitive. HP ProCurve Access Point 420(config-mgmt)#password-admin 1AB2F HP ProCurve Access Point 420(config-mgmt)#
To Set the Access Points IP Address By default, the access point is configured to automatically receive IP addressing from a Dynamic Host Configuration Protocol (DHCP) server. However, if you are not using a DHCP server to configure IP addressing, use the CLI to manually configure the IP values. 1. From the global configuration mode, type interface ethernet to access the Ethernet interface-configuration mode. P o i n t C o n f i g u r a t i o n G e t t i n g S t a r t e d W i t h A c c e s s HP ProCurve Access Point 420(config)#interface ethernet Enter Ethernet configuration commands, one per line. HP ProCurve Access Point 420(if-ethernet)#
3-3 Getting Started With Access Point Configuration 2. Type show to display the access points default IP configuration, including IP address, subnet mask, and default gateway. The following illustration shows the default settings. HP ProCurve Access Point 420(if-ethernet)#show Ethernet Interface Information
IP Address : 192.168.1.1 Subnet Mask : 255.255.255.0 Default Gateway : 192.168.1.254 Primary DNS : 0.0.0.0 Secondary DNS : 0.0.0.0 Speed-duplex : 100Base-TX Full Duplex Admin status : Up Operational status : Up
HP ProCurve Access Point 420(if-ethernet)#
3. To manually assign an IP address, first type no ip dhcp to disable DHCP client mode. Then type ip address ip-address netmask gateway, where ip-address is the access points IP address, netmask is the network mask for the network, and gateway is the default gateway router. Check with your system administrator to obtain an IP address that is compatible with your network. HP ProCurve Access Point 420(if-ethernet)#no ip dhcp HP ProCurve Access Point 420(if-ethernet)#ip address 192.168.2.2 255.255.255.0 192.168.2.254 HP ProCurve Access Point 420(if-ethernet)#
To Set the Access Points Country Code If you are using the ProCurve Wireless Access Point 420 NA (J8130B) model sold in the United States, radio channels 1 - 11 are the only options supported under FCC regulations, and cannot be changed. However, if you are using ProCurve Wireless Access Point 420 WW (J8131B) model sold in other coun-
tries, then you need to set the country code to indicate the channels permitted for your area. The country code can only be set using the CLI. N o t e Setting the Country Code requires a system reboot. 1. First type country ? to display the list of countries. 2. Select the code for your country, and enter the country command again, followed by your country code (for example, GB for Great Britain). 3. Type y to reboot the access point and make the setting effective. HP ProCurve Access Point 420#country gb Reboot system now to make the country code change effective? <y/n>: y Reboot system... 3-4 s s e c c A h t i W d e t r a t S g n i t t e G n o i t a r u g i f n o C t n i o P Getting Started With Access Point Configuration To Configure Radio Settings The access point supports up to eight Service Set IDentifier (SSID) interfaces. Most radio parameters apply globally to all configured SSID interfaces. For each SSID interface, different security settings, VLAN assignments, and other parameters can be applied. One SSID interface on the access point is set as the primary. The primary SSID is the only SSID broadcast in the access points beacon frames. Other created SSID interfaces are set as secondary. Secondary SSIDs are all hidden, only being advertised in probe responses. N o t e The radio is disabled if the Country Code is not set. Once the Country Code is set,the radio can be enabled. 1. From the Exec mode, type the show interface wireless g command to display the access points default radio configuration, including the radio mode, radio channel, and operation status. The following illustration shows the default settings. HP ProCurve Access Point 420#show interface wireless g Wireless Interface Common Information
----------------Identification------------------------------------------
Description : Enterprise 802.11g Access Point Radio mode : 802.11b + 802.11g Channel : 11 (AUTO) Supported SSID number : 8 Supported Total Client number : 128 Status : Disabled
----------------802.11 Parameters----------------------------------------
Transmit Power : FULL (13 dBm) Max Station Data Rate : 54Mbps Multicast Data Rate : 1Mbps Fragmentation Threshold : 2346 bytes RTS Threshold : 2347 bytes Beacon Interval : 100 TUs Authentication Timeout Interval : 60 Mins Association Timeout Interval : 30 Mins DTIM Interval : 1 beacon Preamble Length : SHORT-OR-LONG Slot time : AUTO
----------------Security------------------------------------------------
Static Keys :
Key 1: OPEN Key 2: OPEN Key 3: OPEN Key 4: OPEN
----------------Antenna-------------------------------------------------
Antenna mode : Diversity Antenna gain attenuation Low channel : 100%
Mid channel : 100%
High channel : 100%
HP ProCurve Access Point 420#
3-5 P o i n t C o n f i g u r a t i o n G e t t i n g S t a r t e d W i t h A c c e s s Getting Started With Access Point Configuration 2. Type configure to enter global configuration mode, and then type interface wireless g to access the wireless interface-configuration mode. HP ProCurve Access Point 420#configure Enter configuration commands, one per line. HP ProCurve Access Point 420(config)#interface wireless g Enter Wireless configuration commands, one per line. HP ProCurve Access Point 420(if-wireless-g)#
3. To set the radio channel through which the access point communicates with its wireless clients. Use the default setting (auto) to have the access point automatically select the first available channel. Otherwise, type channel number, where number can be from 1 to 14, depending on the wireless regulations specified by your country. HP ProCurve Access Point 420(if-wireless-g)#channel 9 HP ProCurve Access Point 420(if-wireless-g)#
4. To set the primary Service Set Identifier (SSID) for the access point. Type ssid index 1 to enter SSID interface configuration for the primary SSID interface. Then type ssid identifier, where identifier can consist of up to 32 alphanumeric characters and is case sensitive. HP ProCurve Access Point 420(if-wireless-g)#ssid index 1 HP ProCurve Access Point 420(if-wireless-g-ssid-1)#ssid AP420 HP ProCurve Access Point 420(if-wireless-g-ssid-1)#
5. To enable the radio, type end to return to wireless interface-configuration mode, then type no shutdown to enable the radio interface. HP ProCurve Access Point 420(if-wireless-g-ssid-1)#end HP ProCurve Access Point 420(if-wireless-g)#no shutdown HP ProCurve Access Point 420(if-wireless-g)#
N o t e All settings are immediately saved and retained on a reboot. 3-6 s s e c c A h t i W d e t r a t S g n i t t e G n o i t a r u g i f n o C t n i o P Getting Started With Access Point Configuration Here is some information on the basic IP address and wireless configuration parameters. For more information on these parameters, see the Management and Configuration Guide, which is on the Documentation CD-ROM that came with your access point:
Parameter Username Password IP Address Default admin none The name of the manager. The password for the manager. 192.168.1.1 IP address compatible with your network. Subnet Mask 255.255.255.0 Subnet mask compatible with your network. Default Gateway 192.168.1.254 IP address of the next-hop gateway node for network traffic that needs to be able to reach off-subnet destinations. Primary SSID Enterprise Wireless AP 1 The primary Service Set Identifier (SSID) interface for the access point. Only the primary SSID is broadcast in the access points beacon frames. Channel 0 (AUTO) The radio channel through which the access point communicates with its wireless clients. When attempting to connect, most wireless clients automatically set their radio channel to the same channel used by the access point. Wireless Operation Disabled Wireless operation can only be enabled after you have set the country code. Note: The IP address and subnet mask assigned for the access point must be compatible with the IP addressing used in your network. For more information on IP addressing, see the Management and Configuration Guide, which is on the Documentation CD-ROM that came with your access point. P o i n t C o n f i g u r a t i o n G e t t i n g S t a r t e d W i t h A c c e s s 3-7 Getting Started With Access Point Configuration Where to Go From Here The above procedure, using the CLI, configured your access point with a Manager password, IP address, and subnet mask. As a result, with the proper network connections, you can now manage the access point from a PC equipped with Telnet or a Secure Shell client, or a Web browser interface. The above procedure also configured the primary Service Set Identifier (SSID), the radio channel, and enabled wireless operation. Your wireless clients can now access the network by setting their SSID and radio channel to the same values used by the access point. Note that some wireless clients can be configured to scan all of the radio channels for an access point and the SSID. Some basic information on managing your access point is included in the next section. For more information on the console and Web browser interfaces, and all the features that can be configured on the Access Point 420, please see the Management and Configuration Guide, which is on the Documentation CD-ROM that came with your access point. To Recover from a Lost Manager Password: If you cannot start a con-
sole session because of a lost manager password, you can clear the password and user name by getting physical access to the access point and pressing and holding the Reset button for more than five seconds. However, note that this action resets all configuration settings to the factory defaults. The Reset button is provided for your convenience, but if you are concerned with the security of the access point configuration and operation, you can disable it. For more information, see the Management and Configuration Guide, which is on the Documentation CD-ROM that came with your access point. C a u t i o n 3-8 s s e c c A h t i W d e t r a t S g n i t t e G n o i t a r u g i f n o C t n i o P N o t e Getting Started With Access Point Configuration Using the IP Address for Remote Access Point Management Using the IP Address for Remote Access Point Management With your Access Point 420, you can use the access points IP address to manage the access point from any PC that is on the same subnet as the access point. You can use either a Telnet or Secure Shell (SSH) session, or a standard Web browser to manage the access point. To provide more security for the access point, management interfaces that are not required can be disabled. This includes the Web, Telnet, and SSH, as well as the serial console port and Reset button. For more information, see the Management and Configuration Guide, which is on the Documentation CD-ROM that came with your access point. Starting a Telnet Session To access the access point through a Telnet session, follow these steps:
1. Make sure the access point is configured with an IP address and that the access point is reachable from the PC that is running the Telnet session
(for example, use a ping command to the access points IP address). 2. Start the Telnet program on a PC that is on the same subnet as the access point and connect to the access points IP address. Example:
telnet 192.168.1.19 3. Enter the user name and password. (The default user name is admin and the default password is null. You will then see the access points console command (CLI) prompt, for example:
Username: admin Password:
HP ProCurve Access Point 420#
Enter ? to see a list of commands that can be executed at the prompt. Entering any command followed by ? displays a list of options that are available at that point in the command entry. 3-9 P o i n t C o n f i g u r a t i o n G e t t i n g S t a r t e d W i t h A c c e s s Getting Started With Access Point Configuration Using the IP Address for Remote Access Point Management Starting an SSH Session To access the console through an SSH session, SSH v2.0 client software must be installed on the management station PC. Note that after boot up, the access points SSH server needs about two minutes to generate host encryption keys. The SSH server is disabled while the keys are being generated. N o t e The access point supports only SSH version 2.0. To access the access point through an SSH session, follow these steps:
1. Make sure the access point is configured with an IP address and that the access point is reachable from the PC that is running the SSH session (for example, use a ping command to the access points IP address). 2. Start the SSH client program on a PC that is on the same subnet as the access point and connect to the access points IP address. Example:
ssh 192.168.1.19 3. Enter the Manager user name and password. (The default Manager user name is admin and the default password is null. You will then see the access points console command (CLI) prompt, for example:
Username: admin Password:
HP ProCurve Access Point 420#
Starting a Web Browser Session Your Access Point 420 can be managed through a graphical interface that you can access from any PC or workstation on the same subnet as the access point. Open a compatible browser and type the access points IP address as the URL.
(See Using the Command Line Interface on page 3-2 for information on setting the IP address.) No additional software installation is required to make this interface available; it is included in the access points onboard software. 3-10 s s e c c A h t i W d e t r a t S g n i t t e G n o i t a r u g i f n o C t n i o P Getting Started With Access Point Configuration Using the IP Address for Remote Access Point Management The operating systems, Web browsers, and Java support required to manage the access point through the browser interface are listed in the following table:
Operating System Internet Explorer Netscape Mozilla Windows 2000 Professional 5.01 Windows 2000 Professional SP4 5.01, 2 Windows 2000 Server SP4 5.01, 2 Windows XP Professional version 2002 SP1 Windows XP Professional version 2002 SP2 Windows 2003 Server 6.01, 2 6.01, 2 6.01, 2 Mac OS 9.2 Linux kernal 2.4.18.44 7.02 7.12 7.02 7.12 7.02 7.12 7.02 7.12 7.02 7.12 7.02 7.12 7.0 1.7.32 1.7.32 1.7.32 1.7.32 1.7.32 1.0.1 Mozilla Firefox 1.0PR2 1.0PR2 1.0PR2 1.0PR2 1.0PR2 1.0PR2 Java 1 Microsoft Java Virtual Machine 5.00.3810. 2 Sun Java 2 Runtime Environment Standard Edition v1.4.1 and v1.4.2 Sun Java 2 Runtime Environment Standard Edition v1.4.2 P o i n t C o n f i g u r a t i o n G e t t i n g S t a r t e d W i t h A c c e s s 3-11 Getting Started With Access Point Configuration Using the IP Address for Remote Access Point Management A typical Web browser interface screen is shown in the next illustration. For more information on using the Web browser interface, please see the Management and Configuration Guide, which is on the Documentation CD-ROM that came with your access point. A help system is also available for the Web browser interface. Click the in the upper-right corner of the screen. box 3-12 s s e c c A h t i W d e t r a t S g n i t t e G n o i t a r u g i f n o C t n i o P 4 Using an External Antenna with the Access Point 420 P r o f e s s i o n a l I n s t a l l a t i o n R e q u i r e d The Access Point 420 provides a variety of external antenna options for extending the radio range and shaping the coverge area. These antennas offer a number of different mounting locations, including indoor or outdoor, wall, ceiling, or radio mast. This chapter shows you how to install an external antenna for your Access Point 420. Only the ProCurve Networking antennas listed in this guide are permitted to be connected to the Access Point 420. You must use the appropriate antennas and cables for your given region. You are responsible for verifying local regulations or legislation that may impose restrictions on the use of specific antenna and cable combinations. For this reason, ProCurve Networking recommends that you consult with a professional installer who is trained in RF installation and knowledgeable in the local regulations prior to connecting an external antenna to your wireless radio product. It is the responsibility of the end user to ensure that the antenna installation complies with the local radio regulations. w i t h t h e A c c e s s P o i n t 4 2 0 U s i n g a n E x t e r n a l A n t e n n a 4-1 Using an External Antenna with the Access Point 420 External Antenna Options External Antenna Options The Access Point 420 external antenna options are outlined in the following table:
Table 4-1. Summary of External Antennas to Use With the Access Point 420 Antenna Type Part Number Mounting 2.5 dBi indoor omnidirectional 2 dBi indoor omnidirectional diversity 5 dBi indoor/outdoor omnidirectional 6.5 dBi indoor/outdoor directional diversity J8445A 7 dBi indoor/outdoor directional J8443A 8 dBi outdoor omnidirectional 11 dBi indoor/outdoor wide angle directional 3 dBi indoor omnidirectional diversity J8444A J8446A Horizontal Beamwidth (3dB) Vertical Beamwidth (3dB) 360 Degrees 80 Degrees Access point swivel mount SA2-
05005L-
A5 J8442A Ceiling grid 360 Degrees 80 Degrees J8441A Ceiling or mast 360 Degrees 31 Degrees Flush wall mount, articulating mount for wall or mast Flush wall mount with integrated articulating feature Mast Flush wall mount, tilt mount for mast 80 Degrees 55 Degrees 65 Degrees 50 Degrees 360 Degrees 120 Degrees 12 Degrees 13 Degrees J8997A Ceiling grid 360 Degrees 70 Degrees a n n e t n A l a n r e t x E n a g n i s U 0 2 4 t n i o P s s e c c A e h t h t i w 7 dBi indoor/outdoor directional J8999A Flush wall mount with integrated articulating feature 68 Degrees 66 Degrees 4-2 Using an External Antenna with the Access Point 420 Installation Procedures Installation Procedures Follow these steps to install an external antenna and connect it to the Access Point 420. C a u t i o n Never mount the access point outdoors to be near an external antenna. The access point must always be installed indoors. W a r n i n g 1. Plan the Installation Pigtail Cables - Use the coax pigtail cable attached to the antenna to connect to the access point. Because most pigtail cables are a relatively short length (83 cm or 33 inches), be sure to find a suitable mounting position for the antenna that is not too far from the access point. If an extension cable is required, please contact a professional installer who is trained in RF installation and knowledgeable in the local regulations. Installation Location - Plan the antennas position and orientation. The radiated output power of this device is below the FCC radio exposure limits. Nevertheless, the device should be used in such a manner that the potential for human contact during normal operation is minimized. To avoid the possibility of exceeding the FCC radio frequency exposure limits, human proximity to the antennas should not be less than 20 cm (8 inches) during normal operation. Consider these points:
Use the antennas mounting bracket or other hardware, if included.
For optimum performance, mount antennas as high as possible above any obstructions, and away from any signal absorbing or reflecting structures (such as those containing metal)
Be sure there are no other radio antennas mounted within 2 m (6 ft).
Consider the antennas radio coverage pattern so that it can properly cover the intended service area. Omnidirectional Antennas - Consider these factors when selecting a location for these antennas:
Always mount the antenna in a vertical orientation so that the radio coverage pattern fills the intended horizontal space. w i t h t h e A c c e s s P o i n t 4 2 0 U s i n g a n E x t e r n a l A n t e n n a 4-3 Using an External Antenna with the Access Point 420 Installation Procedures
For optimum coverage, mount the antenna at the center of the area with a line-of-sight path to all points within the area.
Avoid mounting next to or near building support columns or other obstructions that may cause reduced signal or null zones in parts of the coverage area.
When mounting outdoors using a mast, make sure that the antenna extends beyond the top of the mast. Directional Antennas - Consider these factors when selecting a location for these antennas:
For optimum coverage, mount the antenna above any obstructions, directed at the center of the coverage area sector.
High-gain directional antennas provide a flattened radio coverage pattern in the horizontal plane. Use the tilting or articulated mounts to point the antennas towards the coverage area. Outdoor Installation - When installing an antenna outdoors, be sure to consider these additional factors:
Always place the antenna away from power and telephone lines
Make sure that the antenna, any supporting structure, and cables are
all properly grounded. For lightning protection, consider using a lightning arrestor immedi-
ately before the cable enters the building. W a r n i n g Never install an antenna or construct a radio mast near overhead power lines. 2. Mount the Antenna Install the antenna in its planned location using the brackets, clips, or other hardware included in the antenna package. Refer to documentation included with the antenna for specific information and installation instructions. 3. Connect Pigtail Cables to the Access Point Use the pigtail cables that are attached to the antenna, or are included in the antenna package. If an extension cable is required, please contact a profes-
sional installer who is trained in RF installation and knowledgeable in the local regulations. 4-4 a n n e t n A l a n r e t x E n a g n i s U 0 2 4 t n i o P s s e c c A e h t h t i w Using an External Antenna with the Access Point 420 Installation Procedures Note that diversity antennas have two pigtail cables. A diversity antenna includes two internal antenna elements that are identical. Both antenna pigtail cables must be connected to the access point for correct operation. Other non-diversity antennas, which have only one pigtail cable, attach to the access points right antenna connector. The access points right antenna is the one on the side closest to the LED indicators. When using a non-diversity antenna, a 50-ohm terminator (included with the antenna) must be connected to the access points left antenna connector. To connect pigtail cables to the access point, follow these steps:
1. Disable the access point radio using the web browser interface, CLI, or SNMP. 2. Remove power to the access point. 3. Remove both of the access points antennas by unscrewing them at their base. Unscrew antenna to remove Right antenna 4. For diversity antennas, connect the antenna pigtail cables to the exposed Reverse SMA connectors on both sides of the access point. For non-diversity antennas, be sure to connect the single pigtail cable to the Reverse SMA connector on the access points right side. When using a non-diversity antenna, you must also connect the 50-ohm terminator
(5092-0933), included with the antenna, to the access points left-side Reverse SMA connector. w i t h t h e A c c e s s P o i n t 4 2 0 U s i n g a n E x t e r n a l A n t e n n a 4-5 Using an External Antenna with the Access Point 420 Installation Procedures Screw onto access points Reverse SMA connector Antenna pigtail cable 5. Reconnect power to the access point. N o t e Before enabling the radio with an external antenna attached, be sure to first configure the access points antenna mode and transmit power settings. 4. Configure the Antenna Mode and Transmit Power Control Limits Using the Web browser interface, CLI, or SNMP, you must configure the Access Point 420 to use an external antenna. For more information on access point configuration, see the Management and Configuration Guide, which is on the Documentation CD-ROM that came with your access point. The access point must be set for the type of external antenna that is attached, either a diversity antenna that connects to both access point antenna connec-
tors, or non-diversity antenna that has a single pigtail connection. The access points transmit power must be limited to conform to local regu-
lations. Use the regional settings for each antenna and radio mode as provided in the Transmit Power Control tables below. An improper combination of transmit power and antenna gain may result in an EIRP power level in excess of the legally imposed limit. The transmit power reduction required for each antenna in each radio mode is listed in the following tables. Failure to adhere to these guidelines may violate the radio C a u t i o n 4-6 a n n e t n A l a n r e t x E n a g n i s U 0 2 4 t n i o P s s e c c A e h t h t i w Using an External Antenna with the Access Point 420 Installation Procedures laws for your region. For additional information on setting radio transmit power, refer to the Management and Configuration Guide, which is on the Documentation CD-ROM that came with your access point. External Antenna FCC/IC/NCC EU/ETSI Japan 802.11b Transmit Power Control (TPC) Settings (%) 2.5 dBi Indoor Omni, 5092-0723 2 dBi Indoor Diversity, J8442A 5 dBi Indoor/Outdoor Omni, J8441A 6.5 dBi Indoor/Outdoor Directional Diversity, J8445A 7 dBi Indoor/Outdoor Directional, J8443A 8 dBi Outdoor Omni, J8444A 11 dBi Indoor/Outdoor wide angle direc-
tional, J8446A 3 dBi Indoor Omni Diversity, J8997A 7 dBi Indoor/Outdoor Directional, J8999A External Antenna 2.5 dBi Indoor Omni, 5092-0723 2 dBi Indoor Diversity, J8442A 5 dBi Indoor/Outdoor Omni, J8441A 6.5 dBi Indoor/Outdoor Directional Diversity, J8445A 7 dBi Indoor/Outdoor Directional, J8443A 8 dBi Outdoor Omni, J8444A 11 dBi Indoor/Outdoor wide angle direc-
tional, J8446A 3 dBi Indoor Omni Diversity, J8997A 7 dBi Indoor/Outdoor Directional, J8999A L 100 70 63 50 56 56 28 80 32 L 100 80 70 63 70 70 16 100 35 M 100 100 100 100 100 100 63 100 100 H 100 100 80 63 70 70 56 100 100 L 70 100 50 32 28 22 10 63 25 M 70 100 50 32 28 22 10 63 28 H 70 100 50 32 28 22 10 63 28 L 100 100 100 100 100 100 100 100 100 M 100 100 100 100 100 100 100 100 100 802.11g Transmit Power Control (TPC) Settings (%) FCC/IC/NCC EU/ETSI Japan M 100 100 100 100 100 100 13 100 28 H 100 100 80 56 70 56 16 100 35 L 70 100 45 28 25 20 10 63 25 M 80 100 50 35 32 25 11 70 32 H 80 100 50 35 32 32 13 70 32 L 100 100 100 100 100 100 100 100 100 M 100 100 100 100 100 100 100 100 100 H 100 100 100 100 100 100 100 100 100 H 100 100 100 100 100 100 100 100 100 4-7 w i t h t h e A c c e s s P o i n t 4 2 0 U s i n g a n E x t e r n a l A n t e n n a Using an External Antenna with the Access Point 420 Installation Procedures External Antenna FCC/IC/NCC EU/ETSI Japan 802.11b/g (Dual Mode) Transmit Power Control (TPC) Settings (%) 2.5 dBi Indoor Omni, 5092-0723 2 dBi Indoor Diversity, J8442A 5 dBi Indoor/Outdoor Omni, J8441A 6.5 dBi Indoor/Outdoor Directional Diversity, J8445A 7 dBi Indoor/Outdoor Directional, J8443A 8 dBi Outdoor Omni, J8444A 11 dBi Indoor/Outdoor wide angle direc-
tional, J8446A 3 dBi Indoor Omni Diversity, J8997A 7 dBi Indoor/Outdoor Directional, J8999A L 100 70 63 50 56 56 16 80 32 M 100 100 100 100 100 100 13 100 28 H 100 100 80 56 70 56 16 100 35 L 70 100 45 28 25 20 10 63 25 M 70 100 50 32 28 22 10 63 28 H 70 100 50 32 28 22 10 63 28 L 100 100 100 100 100 100 100 100 100 M 100 100 100 100 100 100 100 100 100 H 100 100 100 100 100 100 100 100 100 Setting the Antenna Mode Using the CLI 1. Type configure to enter global configuration mode. HP420#configure Enter configuration commands, one per line. End with CTRL/Z HP420(config)#
2. Type interface wireless g to enter interface configuration mode. HP420(config)#interface wireless g Enter Wireless configuration commands, one per line. HP420(if-wireless g)#
3. Type antenna-mode diversity if using a diversity antenna. HP420(config)#antenna-mode diversity Type antenna-mode single if using a non-diversity antenna. HP420(config)#antenna-mode single 4-8 a n n e t n A l a n r e t x E n a g n i s U 0 2 4 t n i o P s s e c c A e h t h t i w Using an External Antenna with the Access Point 420 Installation Procedures Setting the Antenna Mode Using the Web Interface 1. Select the Configuration tab. 2. Click the [Port/Radio Settings] button. 3. Scroll down to the External Antennas section at the bottom of the page. 4. From the Antenna Mode drop-down menu, select Diversity or Single for the type of antenna attached to the access point. 5. Click the [Apply Changes] button. Antenna Mode selection;
Diversity or Single. Setting Transmit Power Limits Using the CLI 1. Type configure to enter global configuration mode. HP420#configure Enter configuration commands, one per line. End with CTRL/Z HP420(config)#
2. Type interface wireless g to enter interface configuration mode. HP420(config)#interface wireless g Enter Wireless configuration commands, one per line. HP420(if-wireless g)#
w i t h t h e A c c e s s P o i n t 4 2 0 U s i n g a n E x t e r n a l A n t e n n a 4-9 Using an External Antenna with the Access Point 420 Installation Procedures 3. To set the antenna power limits, type transmit-limits followed by the low, middle, and high channel settings as given for the antenna and region in the Transmit Power Control Settings table for that radio mode (b; g; b and g). For example, when using the 6.5 dBi Indoor/Outdoor Directional Diversity antenna (J8445A) in North America with the access point set to dual (b and g) mode, the TPC settings table for dual mode (see page 4-7) indicates the following settings are required: 50% for the low channel, 100% for the middle channel, and 56% for the high channel. For this example, type the following command:
HP420(if-wireless g)#transmit-limits 50 100 56 Setting Transmit Power Limits Using the Web Inteface 1. Select the Configuration tab. 2. Click the [Port/Radio Settings] button. 3. Scroll down to the External Antennas section at the bottom of the page. 4. From the drop-down menu for Low Channel, Mid Channel, and High Channel, select the settings as given for the antenna and region in the Transmit Power Control Settings table for that radio mode (b; g; b and g). 5. Click the [Apply Changes] button. 4-10 a n n e t n A l a n r e t x E n a g n i s U 0 2 4 t n i o P s s e c c A e h t h t i w Using an External Antenna with the Access Point 420 Installation Procedures Transmit Power Control limits for Low, Middle, and High channels. w i t h t h e A c c e s s P o i n t 4 2 0 U s i n g a n E x t e r n a l A n t e n n a 4-11 This page is intentionally unused. Troubleshooting 5 This chapter describes how to troubleshoot your ProCurve Wireless Access Point 420. Note that this document describes troubleshooting mostly from a hardware perspective. You can perform more in-depth troubleshooting on the Access Point 420 using the software tools available with the access point, including the full-featured console interface and the built-in Web browser interface. This chapter describes the following:
T r o u b l e s h o o t i n g basic troubleshooting tips (page 5-1) diagnosing with the LEDs (page 5-3) proactive networking tools (page 5-5) hardware diagnostic tests (page 5-6) restoring the factory default configuration (page 5-8) downloading new software to the Access Point 420 (page 5-10) HP Customer Support Services (page 5-10) Basic Troubleshooting Tips Most problems are caused by the following situations. Check for these items first when starting your troubleshooting:
Connecting to devices that have a fixed full-duplex configuration. By default, the RJ-45 port uses auto-negotiation to determine the duplex mode. That is, when connecting to attached devices, the access point will operate in one of two ways to determine the link speed and the commu-
nication mode (half duplex or full duplex):
If the connected device is also configured to use auto-negotiation, the access point will automatically negotiate both link speed and commu-
nication mode. If the connected device has a fixed configuration, for example 100 Mbps, at half or full duplex, the access point will automatically sense the link speed, but will default to a communication mode of half duplex.
5-1 Troubleshooting Basic Troubleshooting Tips g n i t o o h s e l b u o r T Because the Access Point 420 behaves in this way (in compliance with the IEEE 802.3 standard), if a device connected to the access point has a fixed configuration at full duplex, the device will not connect correctly to the access point. The result will be high error rates and very inefficient communications between the access point and the device. All devices connected to the Access Point 420 should be configured to auto-negotiate. To correct this problem you have to manually set the access points RJ-45 port to match the duplex mode used by the attached device. Faulty or loose cables. Look for loose or obviously faulty connections. If the cables appear to be OK, make sure the connections are secure. If that does not correct the problem, try a different cable. Non-standard cables. Non-standard and miswired cables may cause network collisions and other network problems, and can seriously impair network performance. Use a new correctly-wired cable or compare your cable to the cable in appendix B, Access Point Port and Network Cables for pinouts and correct cable wiring. A category 5 cable tester is a recommended tool for every 100Base-TX network installation. Improper Network Topologies. It is important to make sure you have a valid network topology. Common topology faults include excessive cable length and excessive repeater delays between end nodes. If you have network problems after recent changes to the network, change back to the previous topology. If you no longer experience the problems, the new topology is probably at fault. Sample topologies are shown at the end of chapter 2 in this book, and some topology configuration guidelines can be found online at the ProCurve Networking Web site, http://
www.procurve.com. under network configuration examples. Mobile users cannot connect to the network. Make sure that the access point and wireless clients are configured with compatible security settings. Check to ensure that the wireless client is within the maximum range supported by the access point. Also verify that the wireless client has been configured with an IP address compatible with the attached network, either manually or via DHCP. For more information on possible network problems and their solutions, refer to the technical note Troubleshooting LAN Performance and Intermittent Connectivity Problems, which can be found on the ProCurve Networking Web site, http://www.procurve.com, in the Reference Library section under http://www.hp.com/rnd/library/index.htm under T in the A-Z index. 5-2 Troubleshooting Diagnosing with the LEDs Diagnosing with the LEDs Table 5-1 shows LED patterns on the access point that indicate problem conditions. 1. Check in the table for the LED pattern that you see on your access point. 2. Refer to the corresponding diagnostic tip on the next few pages. T r o u b l e s h o o t i n g Table 5-1. LED Error Indicators LED Pattern Indicating Problems Power Wireless LED 10/100-TX LED Off with power cord plugged in Off without power cord plugged in, but linked to a PoE source Prolonged Blinking On On On
Off
Off with cable connected On, but the port is not communicating Diagnostic Tips 1 2 3 4 5 6
* This LED is not important for the diagnosis. The blinking behavior is an on/off cycle once every 3 seconds, approximately. Diagnostic Tips:
Tip 1 Problem The access point is not plugged into an active AC power source, or the access points AC power adapter may have failed. Solution 1. Verify that the power cord is plugged into an active power source and to the access point's AC power adapter. Make sure these connections are secure. 2. Try power-cycling the access point by unplugging and plugging the power cord back in. 3. If the Power LED is still not on, verify that the AC power source works by plugging another device into the outlet. Or try plugging the access point into a different outlet or try a different power cord. If the power source and power cord are OK and this condition persists, the access points AC power adapter may have failed. Call your HP-authorized network reseller, or use the electronic support services from HP to get assistance. See the Customer Support/
Warranty booklet for more information. 5-3 g n i t o o h s e l b u o r T Troubleshooting Diagnosing with the LEDs Tip 2 3 4 5 6 Problem The access point is not receiving power from the PoE source. The access point has experienced a software failure during self test. Wireless link has been administratively disabled. The 10/100Base-TX network connection is not working properly. The port may be improperly configured. Solution 1. Verify that access points 10/100Base-TX port is attached to a PoE source device. 2. Verify that the PoE source device is powered on, and that the PoE function has been administratively enabled on the source port attached to the access point. 3. Refer to Tip 6 to verify that the network cable is functioning properly. 1. Try resetting the access point by pressing the Reset button on the back of the access point, or by power cycling the access point. 2. If the fault indication reoccurs, attach a console to the access point (as indicated in chapter 2). Then, reset the access point. Messages should appear on the console screen identifying the error condition. You can view the console log at that point using the Web browser interface. Select the Status tab, then Events Log, or view the entry file on your Syslog server if one is configured. If necessary to resolve the problem, contact your HP-authorized network reseller, or use the electronic support services from HP to get assistance. See the Customer Support/
Warranty booklet for more information. Verify that the wireless port has not been disabled through an access point configuration change. You can use the console interface, or, if you have configured an IP address on the access point, use the Web browser interface to determine the state of the wireless port and re-enable the port if necessary. Also verify that the country code has been set. Try the following procedures:
Verify that both ends of the cabling, at the access point and the connected device, are connected properly.
Verify the connected device and access point are both powered on and operating correctly.
Verify duplex operation (see page 5-1).
If these procedures dont resolve the problem, try using a different cable. VLAN configuration may affect the port operation. Use the access points console to see how the port is configured for VLANs. Make sure also, that the device at the other end of the connection is indicating a good link to the access point. If it is not, the problem may be with the cabling between the devices or the connectors on the cable. 5-4 Troubleshooting Proactive Networking T r o u b l e s h o o t i n g Proactive Networking The following interfaces provide tests, indicators, and an event log that can be used to monitor the access point and its network connections and to help you troubleshoot:
A graphical Web browser interface that you can use to manage your access point from a PC running a supported Web browser, for example Microsoft Internet Explorer. The Status tab can be used to display access point configuration settings, attached client station settings, and the event log. A full-featured easy-to-use console interface that you can access by connecting a standard terminal or PC running a terminal emulator to the access points console port. (For information on the console ports pin assignments, see Direct Console Access on page 2-12.) The console interface is also accessible through a Telnet or Secure Shell connection. The ping command can test device access and connectivity. The show command at all levels of the CLI provides detailed access point configu-
ration information. 5-5 Troubleshooting Hardware Diagnostic Tests g n i t o o h s e l b u o r T Hardware Diagnostic Tests Testing the Access Point by Resetting It If you believe that the access point is not operating correctly, you can reset the access point to test its circuitry and operating code. To reset an access point, either Unplug and plug in the power cord (power-cycling). Press the Reset button on the back of the access point for just a second. If you are attached to the console port, you will see that the access point starts the power-on self test. C a u t i o n If you hold the reset button down for 5-10 seconds, you reset the board and reload the factory default settings. See Restoring the Factory Default Config-
uration on page 5-8. Power-cycling the access point and pressing the Reset button both cause the access point to perform its power-on self test, which normally resolves any temporary operational problems. These reset processes also cause any network traffic counters to be reset to zero, and cause the System Up Time timer to reset to zero. Also, event log messages are erased, and the IP address may be changed if you are using DHCP. Checking the Access Points LEDs The self test passes if the Power LED on the front of the access point stops blinking after approximately 50 seconds. If this LED continues blinking longer than 60 seconds or goes off, there may be a problem with the access point. See Diagnosing with the LEDs on page 5-3 for information on interpreting the LED patterns. Checking Event Messages Useful diagnostic messages may be displayed on the console screen when the access point is reset. As described in chapter 2 under step 7, Connect a console to the access point, connect a PC running a VT-100 terminal emulator program or a standard VT-100 terminal to the access points Console Port and configure it with the terminal communication settings shown on page 2-11. 5-6 T r o u b l e s h o o t i n g Troubleshooting Hardware Diagnostic Tests Then, when you reset the access point, note the messages that are displayed. Additionally, you can check the access points event log, which can be accessed from the Web browser or a Syslog server. Testing Twisted-Pair Cabling Network cables that fail to provide a link or provide an unreliable link between the access point and the connected network device may not be compatible with the IEEE 802.3 Type 10Base-T, or 100Base-TX standards. The twisted-pair cables attached to the Access Point 420 must be compatible with the appro-
priate standards. To verify that your cable is compatible with these standards, use a qualified cable test device. Testing Access Point-to-Device Network Communications You can perform the following communication tests to verify that the network is operating correctly between the access point and any connected device that can respond correctly to the communication test. Ping Test -- a network layer test used on IP networks that sends test packets to any device identified by its IP address These tests can be performed through the access points console interface from a terminal connected to the access point or through a Telnet or Secure Shell connection. For more information, see the Management and Configu-
ration Guide, which is on the Documentation CD-ROM that came with your access point. Testing End-to-End Network Communications Both the access point and the cabling can be tested by running an end-to-end communications test -- a test that sends known data from one network device to another through the access point. You can run a Ping test to verify that the entire communication path between the two network devices is functioning correctly. 5-7 Troubleshooting Restoring the Factory Default Configuration Restoring the Factory Default Configuration As part of your troubleshooting process on the Access Point 420, it may become necessary to return the access points configuration to the factory default settings. This process momentarily interrupts the access points oper-
ation, clears any passwords, clears the console event log, resets the network counters to zero, performs a complete self test, and reboots the access point into its factory default configuration including deleting the IP address, if one is configured. This process removes all access point configuration changes that you have made from the factory default settings. This includes, for example, IP addresses, and radio interface settings. Returning the configuration of these features to their factory default settings may result in network connectivity issues. If the access point has a valid configuration, and you are restoring the factory default settings for a reason other than configuration problems, you should save the access point configuration prior to performing the factory default reset. Then, after the reset and resolution of the original problem, you can restore the saved configuration to the access point. For both the save and restore processes, you can use the console copy command. For more informa-
tion on this command, see the Management and Configuration Guide, which is on the Documentation CD-ROM that came with your access point. You can restore the factory default configuration either from the access point itself, or through the access point console. The Reset button and console port can be disabled by the access points software. However, the Reset button and console port cannot be disabled at the same time. When the Reset button is disabled, it is not possible to disable the serial port. For more information, see the Management and Configura-
tion Guide, which is on the Documentation CD-ROM that came with your access point. g n i t o o h s e l b u o r T N o t e N o t e 5-8 Troubleshooting Restoring the Factory Default Configuration To execute the factory default reset on the access point, perform these steps:
1. Using a pointed object, press and hold the Reset button on the back of the access point for 5-10 seconds. On the console display, the cursor will move down to the next line, indicating that the factory defaults have been reloaded. 2. Release the Reset button. The access point will then complete its self test and begin operating with its configuration restored to the factory default settings. To restore the factory default configuration using the console, execute the reset configuration command from the console command prompt. T r o u b l e s h o o t i n g 5-9 Troubleshooting Downloading New Access Point Software Downloading New Access Point Software When product enhancements occur for the Access Point 420, new software can be downloaded to the access point by several methods. For more infor-
mation, see the Management and Configuration Guide, which is on the Documentation CD-ROM that came with your access point. The new access point software is made available on the ProCurve Networking Web site, http://www.procurve.com under product support software upgrades. HP Customer Support Services If you are still having trouble with your access point, Hewlett-Packard offers support 24 hours a day, seven days a week through the use of a number of automated electronic services. See the Customer Support/Warranty booklet that came with your access point for information on how to use these services to get technical support. The ProCurve Networking Web site, http://
www.procurve.com also provides up-to-date support information under product support. Additionally, your HP-authorized network reseller can provide you with assis-
tance, both with services that they offer and with services offered by HP. Before Calling Support To make the support process most efficient, before calling your networking dealer or HP Support, you first should retrieve the following information:
Information Item Information Location
product identification
details about the access points status including the software (OS) version, a copy of the access point configuration, a copy of the access point Event Log, and a copy of the access point status and counters information the front of the access point, Access Point 420 (HP J8130B or HP J8131B)
access point console (Global Configura-
tion Level): show command
access point Web interface: Event Log
Syslog server entry file, if configured g n i t o o h s e l b u o r T 5-10 Troubleshooting HP Customer Support Services Information Item Information Location
copy of your network topology map, in-
cluding network addresses assigned to the relevant devices your network records T r o u b l e s h o o t i n g 5-11 This page is intentionally unused. A S p e c i f i c a t i o n s Specifications Physical Width:
Depth:
Height:
Weight:
Electrical Adapter AC voltage:
DC voltage:
21.83 cm (8.60 in) 13.73 cm (5.40 in) 3.27 cm (1.29 in) 0.80 kg (1.76 lbs) 100-240 volts, 0.4A, 50/60 Hz 3.3 volts, 4A Power consumption:
13.2 watts PoE (DC) Input voltage:
-48 VDC, 0.15A, 7.2 watts Note: Power can also be provided to the access point through the Ethernet port based on IEEE 802.3af Power over Ethernet (PoE) specifications. The accees point is a Class 0 device, that is, the maximum power required is in the range of 0.44 to 12.95 watts. When both PoE is provided and the adapter is plugged in, PoE is turned off. Environmental Operating 0 C to 40 C (32 F to 104 F) 15% to 95% at 40C (104F) Non-Operating
-40 C to 70 C (-40 F to 158 F) 90% maximum at 65 C (149 F) Temperature:
Relative humidity:
(non-condensing) Maximum altitude:
4.6 Km (15,000 ft) 4.6 Km (15,000 ft) A-1 Specifications Connectors The 10/100 Mbps RJ-45 twisted-pair port is compatible with the IEEE 802.3u 100Base-TX and IEEE 802.3 Type 10Base-T standards. Note: To provide Power over Ethernet to the access point, all 4 pairs of wires must be connected for any network cable attached to this port. Safety Complies with:
EN 60950-1 EMC Compliance (Class B) Complies with:
FCC Part 15.107 ICES-003 (Canada) EN 55022 VCCI Telecom Complies with:
FCC Part 15.247 (2.4GHz) RSS-210 (Canada) EN 300.328 MPT RCR Std. 33 (D33 1~13 Channel, T66 Channel 14) Immunity EN 301.489-1 EN 301.489-17 s n o i t a c i f i c e p S A-2 Specifications Wireless Radio Standard:
IEEE 802.11b/g Radio Technology:
Direct Sequence Spread Spectrum (DSSS), Orthogonal Frequency Division Multiplexing (OFDM) Data Rate:
1, 2, 5.5, 6, 9, 11, 12, 18, 24, 36, 48, 54 Mbps per channel Operating Frequency:
2.4 ~ 2.4835 GHz (US, Canada, ETSI) 2.4 ~ 2.497 GHz (Japan) Maximum Channels:
FCC/IC: 1-11, ETSI: 1-13, MKK: 1-13 (802.11g), 1-14 (802.11b) Modulation Type:
BPSK, QPSK, 16QAM, 64QAM / OFDM, BPSK, QPSK, CCK / DSSS Media Access Protocol:
CSMA/CA with ACK Operating Range:
Up to 350 m (1148 ft) Transmit Output Power:
19 dBm Receiver Sensitivity Data Rate (Mbps) Typical Receiver Sensitivity (dBm) at 25C 1 11 54
-94
-89
-71 S p e c i f i c a t i o n s A-3 This page is intentionally unused. B Access Point Port and Network Cables This appendix includes access point connector information and network cable information for cables that should be used with the Access Point 420, including minimum pin-out information and specifications for twisted-pair cables. N o t e Incorrectly wired cabling is the most common cause of problems for LAN communications. ProCurve Networking recommends that you work with a qualified LAN cable installer for assistance with your cabling requirements. Access Point Ports The fixed RJ-45 10/100Base-TX port on the access point accepts 100-ohm unshielded and shielded twisted-pair cable with RJ-45 connectors as described on the next page. Twisted-Pair Cables 10 Mbps Operation Category 3, 4, or 5 100-ohm unshielded twisted-pair (UTP) or shielded twisted-pair (STP) cable, complying with IEEE 802.3 Type 10Base-T specifications, fitted with RJ-45 connectors 100 Mbps Operation Category 5 100-ohm UTP or STP cable, complying with IEEE 802.3u 100Base-TX specifications, fitted with RJ-45 connectors B-1 N e t w o r k C a b l e s A c c e s s P o i n t P o r t a n d Access Point Port and Network Cables Twisted-Pair Cable/Connector Pin-Outs Twisted-Pair Cable/Connector Pin-Outs The access point includes one 10/100Base-TX port. This port uses MDI (i.e., internal straight-through) pin configuration. You can therefore use straight-
through twisted-pair cable to connect this port to most network interconnec-
tion devices such as a switch or a router that provide MDI-X ports. However, if you need to connect the access point to a workstation or other device that only has MDI ports, then use crossover twisted-pair cable. Ports on most ProCurve Networking switches have the HP Auto MDIX feature, which means that you can use either straight-through or crossover twisted-pair cables to connect the access point to the switch. Other Wiring Rules:
All twisted-pair wires used for 10 Mbps, and 100 Mbps operation must be twisted through the entire length of the cable. The wiring sequence must conform to EIA/TIA 568-B (not USOC). See Twisted-Pair Cable Pin Assignments later in this appendix for a listing of the signals used on each pin. For 10 Mbps connections to the ports, you can use Category 3, 4, or 5 unshielded twisted-pair cable, as supported by the IEEE 802.3 Type 10Base-T standard. For 100 Mbps connections to the ports, use 100-ohm Category 5 UTP or STP cable only, as supported by the IEEE 802.3u Type 100Base-TX stan-
dard. To provide Power over Ethernet to the access point, all 4 pairs must be connected for any network cable attached to this port; the cable must meet ISO/DIS 11801 Class D requirements and IEEE 802.3af requirements. B-2 d n a t r o P t n i o P s s e c c A s e l b a C k r o w t e N Access Point Port and Network Cables Twisted-Pair Cable/Connector Pin-Outs Straight-Through Twisted-Pair Cable for 10 Mbps or 100 Mbps Network Connections Because the 10/100 port on the access point uses an MDI pin configuration, you must use straight-through cable for network connections to hubs or switches that only have MDI-X ports. However, if the device to which you are connecting supports auto-MDIX operation, you can use either straight-
through or crossover cable. Cable Diagram N o t e
. Pins 1 and 2 on connector A must be wired as a twisted pair to pins 1 and 2 on connector B. Pins 3 and 6 on connector A must be wired as a twisted pair to pins 3 and 6 on connector B. Pins 4, 5, 7, and 8 are not used for transmitting or receiving data, although they must be wired straight-through in the cable to support Power over Ethernet. Pin Assignments Access Point End (MDI) Signal Pins receive +
receive -
transmit +
transmit -
1 2 3 6 Hub or Switch Port, or Other MDI-X Port End Pins Signal 1 2 3 6 transmit +
transmit -
receive +
receive -
B-3 N e t w o r k C a b l e s A c c e s s P o i n t P o r t a n d Access Point Port and Network Cables Twisted-Pair Cable/Connector Pin-Outs Crossover Twisted-Pair Cable for 10 Mbps or 100 Mbps Network Connection Because the 10/100 port on the access point uses an MDI pin configuration, you must use crossover cable for network connections to PCs, servers or other end nodes that only have MDI ports. However, if the device to which you are connecting supports auto-MDIX operation, you can use either straight-
through or crossover cable. Cable Diagram Pins 1 and 2 on connector A must be wired as a twisted pair to pins 3 and 6 on connector B. Pins 3 and 6 on connector A must be wired as a twisted pair to pins 1 and 2 on connector B. Pins 4, 5, 7, and 8 are not used for transmitting or receiving data, although they must be wired straight-through in the cable to support Power over Ethernet. Pin Assignments Access Point End (MDI) Signal Pins receive +
receive -
transmit +
transmit -
1 2 3 6 Computer, Transceiver, or Other MDI Port End Pins Signal 6 3 2 1 transmit -
transmit +
receive -
receive +
N o t e
. B-4 d n a t r o P t n i o P s s e c c A s e l b a C k r o w t e N Safety and EMC Regulatory Statements C Safety Information
WARNING CAUTION Documentation reference symbol. If the product is marked with this symbol, refer to the product documentation to get more information about the product. A WARNING in the manual denotes a hazard that can cause injury or death. A CAUTION in the manual denotes a hazard that can damage equipment. Do not proceed beyond a WARNING or CAUTION notice until you have understood the hazardous conditions and have taken appro-
priate steps. Grounding This product is a safety class I compliant product and has a protective earthing terminal. There must be an uninterruptible safety earth ground from the main power source to the product's power cord or supplied power cord set. Whenever it is likely that the protection has been impaired, disconnect the power cord until the ground has been restored.. For LAN cable grounding:
If your LAN covers an area served by more than one power distribu-
tion system, be sure their safety grounds are securely interconnected. LAN cables may occasionally be subject to hazardous transient volt-
ages (such as lightning or disturbances in the electrical utilities power grid). Handle exposed metal components of the network with caution. Servicing There are no user-serviceable parts inside this product. Any servicing, adjust-
ment, maintenance, or repair must be performed only by service-trained personnel. This product does not have a power switch; it is powered on when the power cord is plugged in. S t a t e m e n t s S a f e t y a n d E M C R e g u l a t o r y C-1 Safety and EMC Regulatory Statements Safety Information Regulatory Model Identification Number For regulatory identification purposes, this product has been assigned a Regulatory Model Number (RMN). The RMN for your product is RSVLC-
0301B. The RMN should not be confused with the marketing name (Wire-
less Enterprise Access Point 420) or the Product Number (J8130B, J8131B). y r o t a l u g e R C M E d n a y t e f a S s t n e m e t a t S C-2 Safety and EMC Regulatory Statements Informations concernant la scurit Informations concernant la scurit
Symbole de rfrence la documentation. Si le produit est marqu de ce symbole, reportez-vous la documentation du produit afin d'obtenir des informations plus dtailles. WARNING CAUTION Dans la documentation, un WARNING indique un danger susceptible d'entraner des dommages corporels ou la mort. Un texte de mise en garde intitul CAUTION indique un danger suscep-
tible de causer des dommages l'quipement. Ne continuez pas au-del d'une rubrique WARNING ou CAUTION avant d'avoir bien compris les conditions prsentant un danger et pris les mesures appropries. Cet appareil est un produit de classe I et possde une borne de mise la terre. La source d'alimentation principale doit tre munie d'une prise de terre de scurit installe aux bornes du cblage d'entre, sur le cordon d'alimentation ou le cordon de raccordement fourni avec le produit. Lorsque cette protection semble avoir t endommage, dbrancher le cordon d'alimentation jusqu' ce que la mise la terre ait t rpare. Mise la terre du cble de rseau local:
si votre rseau local s'tend sur une zone desservie par plus d'un systme de distribution de puissance, assurez-vous que les prises de terre de scurit soient convenablement interconnectes. Les cbles de rseaux locaux peuvent occasionnellement tre soumis des surtensions transitoires dangereuses (telles que la foudre ou des perturba-
tions dans le rseau d'alimentation public). Manipulez les composants mtalliques du rseau avec prcautions. Aucune pice contenue l'intrieur de ce produit ne peut tre rpare par l'utilisateur. Tout dpannage, rglage, entretien ou rparation devra tre confi exclusivement un personnel qualifi. Cet appareil ne comporte pas de commutateur principal ; la mise sous tension est effectue par branchement du cordon d'alimentation. S t a t e m e n t s S a f e t y a n d E M C R e g u l a t o r y C-3 Safety and EMC Regulatory Statements Hinweise zur Sicherheit Hinweise zur Sicherheit
WARNING CAUTION Symbol fr Dokumentationsverweis. Wenn das Produkt mit diesem Symbol markiert ist, schlagen Sie bitte in der Produktdokumentation nach, um mehr Informationen ber das Produkt zu erhalten. Eine WARNING in der Dokumentation symbolisiert eine Gefahr, die Verletzungen oder sogar Todesflle verursachen kann. CAUTION in der Dokumentation symbolisiert eine Gefahr, die dis Gert beschdigen kann. Fahren Sie nach dem Hinweis WARNING oder CAUTION erst fort, nachdem Sie den Gefahrenzustand verstanden und die entsprech-
enden Manahmen ergriffen haben. Dies ist ein Gert der Sicherheitsklasse I und verfgt ber einen schtzenden Erdung-
sterminal. Der Betrieb des Gerts erfordert eine ununterbrochene Sicherheitserdung von der Hauptstromquelle zu den Gerteingabeterminals, den Netzkabeln oder dem mit Strom belieferten Netzkabelsatz voraus. Sobald Grund zur Annahme besteht, da der Schutz beeintrchtigt worden ist, das Netzkabel aus der Wandsteckdose herausz-
iehen, bis die Erdung wiederhergestellt ist. Fr LAN-Kabelerdung:
Wenn Ihr LAN ein Gebiet umfat, das von mehr als einem Stromverteilungs-
system beliefert wird, mssen Sie sich vergewissern, da die Sicherheitserdungen fest untereinander verbunden sind. LAN-Kabel knnen gelegentlich gefhrlichen bergangsspannungen aus-
gesetzt werden (beispielsweise durch Blitz oder Strungen in dem Starkstromnetz des Elektrizittswerks). Bei der Handhabung exponierter Metallbestandteile des Netzwerkes Vorsicht walten lassen. y r o t a l u g e R C M E d n a y t e f a S s t n e m e t a t S Dieses Gert enthlt innen keine durch den Benutzer zu wartenden Teile. Wartungs-, Anpassungs-, Instandhaltungs- oder Reparaturarbeiten drfen nur von geschultem Bedienungspersonal durchgefhrt werden. Dieses Gert hat keinen Netzschalter; es wird beim Anschlieen des Netzkabels eingeschaltet. C-4 Safety and EMC Regulatory Statements Considerazioni sulla sicurezza Considerazioni sulla sicurezza
WARNING CAUTION Simbolo di riferimento alla documentazione. Se il prodotto contras-
segnato da questo simbolo, fare riferimento alla documentazione sul prodotto per ulteriori informazioni su di esso. La dicitura WARNING denota un pericolo che pu causare lesioni o morte. La dicitura CAUTION denota un pericolo che pu danneggiare le attrezzature. Non procedere oltre un avviso di WARNING o di CAUTION prima di aver compreso le condizioni di rischio e aver provveduto alle misure del caso. Questo prodotto omologato nella classe di sicurezza I ed ha un terminale protettivo di collegamento a terra. Dev'essere installato un collegamento a terra di sicurezza, non interrompibile che vada dalla fonte d'alimentazione principale ai terminali d'entrata, al cavo d'alimentazione oppure al set cavo d'alimentazione fornito con il prodotto. Ogniqualvolta vi sia probabilit di danneggiamento della protezione, disinserite il cavo d'alimentazione fino a quando il collegaento a terra non sia stato ripristinato. Per la messa a terra dei cavi LAN:
se la vostra LAN copre un'area servita da pi di un sistema di distribuzione elettrica, accertatevi che i collegamenti a terra di sicurezza siano ben collegati fra loro;
i cavi LAN possono occasionalmente andare soggetti a pericolose tensioni transitorie (ad esempio, provocate da lampi o disturbi nella griglia d'alimen-
tazione della societ elettrica); siate cauti nel toccare parti esposte in metallo della rete. Nessun componente di questo prodotto pu essere riparato dall'utente. Qualsiasi lavoro di riparazione, messa a punto, manutenzione o assistenza va effettuato esclusi-
vamente da personale specializzato. Questo apparato non possiede un commutatore principale; si mette scotto tensione all'inserirsi il cavo d'alimentazione. S t a t e m e n t s S a f e t y a n d E M C R e g u l a t o r y C-5 Safety and EMC Regulatory Statements Consideraciones sobre seguridad Consideraciones sobre seguridad
WARNING CAUTION Smbolo de referencia a la documentacin. Si el producto va marcado con este smbolo, consultar la documentacin del producto a fin de obtener mayor informacin sobre el producto. Una WARNING en la documentacin seala un riesgo que podra resultar en lesiones o la muerte. Una CAUTION en la documentacin seala un riesgo que podra resultar en averas al equipo. No proseguir despus de un smbolo de WARNING o CAUTION hasta no haber entendido las condiciones peligrosas y haber tomado las medidas apropiadas. Este aparato se enmarca dentro de la clase I de seguridad y se encuentra protegido por una borna de puesta a tierra. Es preciso que exista una puesta a tierra continua desde la toma de alimentacin elctrica hasta las bornas de los cables de entrada del aparato, el cable de alimentacin o el juego de cable de alimentacin suministrado. Si existe la probabilidad de que la proteccin a tierra haya sufrido desperfectos, desenchufar el cable de alimentacin hasta haberse subsanado el problema. Puesta a tierra del cable de la red local (LAN):
Si la LAN abarca un rea cuyo suministro elctrico proviene de ms de una red de distribucin de electricidad, cerciorarse de que las puestas a tierra estn conectadas entre s de modo seguro. Es posible que los cables de la LAN se vean sometidos de vez en cuando a voltajes momentneos que entraen peligro (rayos o alteraciones en la red de energa elctrica). Manejar con precaucin los componentes de metal de la LAN que estn al descubierto. Este aparato no contiene pieza alguna susceptible de reparacin por parte del usuario. Todas las reparaciones, ajustes o servicio de mantenimiento debe realizarlos sola-
mente el tcnico. Este producto no tiene interruptor de potencia; se activa cuando se enchufa el cable de alimentacin. C-6 y r o t a l u g e R C M E d n a y t e f a S s t n e m e t a t S Safety and EMC Regulatory Statements Safety Information (Japan) Safety Information (Japan) S t a t e m e n t s S a f e t y a n d E M C R e g u l a t o r y C-7 Safety and EMC Regulatory Statements Safety Information (China) Safety Information (China) y r o t a l u g e R C M E d n a y t e f a S s t n e m e t a t S C-8 Safety and EMC Regulatory Statements EMC Regulatory Statements EMC Regulatory Statements Notice for U.S.A. Manufacturer's FCC Declaration of Conformity Statement Tested to Comply with FCC Standards Product No:
FCC ID No:
Manufacturer:
Phone:
J8130B B94RSVLC-0301B Joy Technology (Shenzhen) Co. Ltd. Hengkeng Industrial, Shangpai, Shangwu, Aiqun Rd., Shiyan Town, Shenzhen 518108, P.R. China
+86-0755-33816888 For questions regarding this declaration, contact the Product Regulations Manager at the above address or phone number. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with instruc-
tions, may cause harmful interference to radio communications. However, there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient the receiving antenna Connect the equipment into an outlet on a circuit different from that to Increase the separation between the equipment and receiver which the receiver is connected Consult the dealer or an experienced radio/TV technician for help This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) this device may not cause harmful interfer-
ence, and 2) this device must accept any interference received, including interference that may cause undesired operation. C-9 S t a t e m e n t s S a f e t y a n d E M C R e g u l a t o r y Safety and EMC Regulatory Statements EMC Regulatory Statements FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.
Warning: FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm (8 inches) between the radiator and your body. This transmitter must not be co-located or operating in conjunc-
tion with any other antenna or transmitter. The availability of some specific channels and/or operational frequency bands are country dependent and are firmware programmed at the factory to match the intended destination. The firmware setting is not accessible by the end user. Notice for Canada This device complies with RSS-210 of the Industry Canada Rules. Operation is subject to the following two conditions: 1) this device may not cause interference, and 2) this device must accept any interference, including inter-
ference that may cause undesired operation of the device. This device has been designed to operate with an antenna having a maximum gain of 10.7 dBi. Antennas having a higher gain is strictly prohibited per regulations of Industry Canada. The required antenna impedance is 50 ohms. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the EIRP is not more than required for successful communication.
Warning: IC Radiation Exposure Statement This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm (8 inches) between the radiator and your body. C-10 y r o t a l u g e R C M E d n a y t e f a S s t n e m e t a t S Safety and EMC Regulatory Statements EMC Regulatory Statements Notice for European Community 0560 !
This device complies with the EMC Directive 89/336/EEC, Low Voltage Direc-
tive 2006/95/EC and R&TTE Directive 1999/5/EC. Compliance with these directives implies conformity to the following European Norms:
EN 55022 (CISPR 22) - Electromagnetic Emissions
EN 55024 (IEC 61000-4-2, 3, 4, 5, 6, 8, 11) - Electromagnetic Immunity
EN 61000-3-2 (IEC 61000-3-2) - Power Line Harmonics
EN 61000-3-3 (IEC 61000-3-3) - Power Line Flicker
EN 60950-1 (IEC 60950-1) - Product Safety
EN 300 328 - Technical requirements for 2.4 GHz radio equipment
EN 301 489-1 / EN 301 489-17 - General EMC requirements for radio equipment EU country restriction notices This device may be used in the following EU and EFTA countries:
Austria Belgium Cyprus Czech Republic Denmark Estonia Finland
France1 Germany Greece Hungary Iceland Ireland Italy Notes:
Latvia Liechtenstein Lithuania Luxembourg
Malta
Netherlands Norway
Poland Portugal Slovakia Slovenia Sweden Switzerland United Kingdom 1. In France, this device may use the entire 2400-2483.5 MHz band (Channels 1-13) for indoor applications. For outdoor use, only the 2400-2454 MHz band (Channels 1-9) may be used. For the latest requirements, visit http://www.art-telecom.fr. 2. For up-to-date information on worldwide country authorizations, power levels and usage restrictions, please visit http://www.hp.com/go/
hpprocurve. Click on technical support, then manuals. Select your wire-
less product and open the document Wireless Radio Country Approvals Matrix. S t a t e m e n t s S a f e t y a n d E M C R e g u l a t o r y C-11 Safety and EMC Regulatory Statements EMC Regulatory Statements EU Declaration of Conformity DECLARATION OF CONFORMITY according to ISO/IEC 17050-1 and EN 17050-1 DoC #: RSVLC-0301B-01 Suppliers Name:
Hewlett-Packard Company Manufacturer's Address: 8000 Foothills Blvd., Roseville, CA 95747 U.S.A. declares, that the product Product Name:
Procurve Wireless Access Point 420 Product Number(s):
J8130B, J8131B Regulatory Model No: RSVLC-0301B Product Options:
J8441A, J8442A, J8443A, J8444A, J8445A, J8446A, J8997A, J8999A conforms to the following Product Specifications:
Safety: EN 60950-1:2001 EMC:
EN 55022:1998 +A1:2000 +A2:2003 Class B EN 61000-3-2:2000 EN 61000-3-3:1995 +A1:2001 Telecom: EN 300 328-1 V1.6.1 EN 301 489-1 V1.6.1 EN 301 489-17 V1.2.1 EN 50385:2002 Supplementary Information:
The product herewith complies with the requirements of the Low Voltage Directive 2006/95/EC, the EMC Directive 89/336/EEC and the R&TTE Directive 1999/5/EC and carries the CE marking accordingly. For regulatory identification purposes, this product has been assigned a Regulatory Model Number (RMN). The RMN for your product is RSVLC-0301B. The RMN should not be confused with the marketing name (Wireless Access Point420) or the Product Number
(J8130B, J8131B). Roseville, February 23, 2007 Local contact for regulatory information:
EMEA: Hewlett-Packard GmbH, HQ-TRE, Herrenberger Strae 140, D-71034 Bblingen, Germany U.S.:
Hewlett-Packard, 3000 Hanover St., Palo Alto, CA 94304, U.S.A. 650-857-1501 C-12 y r o t a l u g e R C M E d n a y t e f a S s t n e m e t a t S Safety and EMC Regulatory Statements EMC Regulatory Statements Notice for Japan S t a t e m e n t s S a f e t y a n d E M C R e g u l a t o r y C-13 This page is intentionally unused. Recycle Statements Waste Electrical and Electronic Equipment (WEEE) Statements D R e c y c l e S t a t e m e n t s Disposal of Waste Equipment by Users in Private Household in the European Union This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city office, your household waste disposal service or the shop where you purchased the product. Likvidace zazen soukrommi domcmi uivateli v Evropsk unii Tento symbol na produktu nebo balen oznauje vrobek, kter nesm bt vyhozen spolu s ostatnm domcm odpadem. Povinnost uivatele je pedat takto oznaen odpad na pedem uren sbrn msto pro recyklaci elektrickch a elektronickch zazen. Okamit tdn a recyklace odpadu pome uchovat prodn prosted a zajist takov zpsob recyklace, kter ochrn zdrav a ivotn prosted lovka. Dal informace o monostech odevzdn odpadu k recyklaci zskte na pslunm obecnm nebo mstskm ad, od firmy zabvajc se sbrem a svozem odpadu nebo v obchod, kde jste produkt zakoupili. Bortskaffelse af affald fra husstande i den Europiske Union Hvis produktet eller dets emballage er forsynet med dette symbol, angiver det, at produktet ikke m bortskaffes med andet almindeligt husholdningsaffald. I stedet er det dit ansvar at bortskaffe kasseret udstyr ved at aflevere det p den kommunale genbrugsstation, der forestr genvinding af kasseret elektrisk og elektronisk udstyr. Den centrale modtagelse og genvinding af kasseret udstyr i forbindelse med bortskaffelsen bidrager til bevarelse af naturlige ressourcer og sikrer, at udstyret genvindes p en mde, der beskytter bde mennesker og milj. Yderligere oplysninger om, hvor du kan aflevere kasseret udstyr til genvinding, kan du f hos kommunen, den lokale genbrugsstation eller i den butik, hvor du kbte produktet. Seadmete jtmete krvaldamine eramajapidamistes Euroopa Liidus See tootel vi selle pakendil olev smbol nitab, et knealust toodet ei tohi koos teiste majapidamisjt-
metega krvaldada. Teie kohus on oma seadmete jtmed krvaldada, viies need elektri- ja elektrooni-
kaseadmete jtmete ringlussevtmiseks selleks ettenhtud kogumispunkti. Seadmete jtmete eraldi kogumine ja ringlussevtmine krvaldamise ajal aitab kaitsta loodusvarasid ning tagada, et ringlussev-
tmine toimub viisil, mis kaitseb inimeste tervist ning keskkonda. Lisateabe saamiseks selle kohta, kuhu oma seadmete jtmed ringlussevtmiseks viia, vtke palun hendust oma kohaliku linnakantselei, majapidamisjtmete krvaldamise teenistuse vi kauplusega, kust Te toote ostsite. D-1 s t n e m e t a t S e l c y c e R Recycle Statements Waste Electrical and Electronic Equipment (WEEE) Statements Laitteiden hvittminen kotitalouksissa Euroopan unionin alueella Jos tuotteessa tai sen pakkauksessa on tm merkki, tuotetta ei saa hvitt kotitalousjtteiden mukana. Tllin hvitettv laite on toimitettava shklaitteiden ja elektronisten laitteiden kierrtyspisteeseen. Hvitettvien laitteiden erillinen ksittely ja kierrtys auttavat sstmn luonnonvaroja ja varmistamaan, ett laite kierrtetn tavalla, joka est terveyshaitat ja suojelee luontoa. Listietoja paikoista, joihin hvitettvt laitteet voi toimittaa kierrtettvksi, saa ottamalla yhteytt jtehuoltoon tai liikkeeseen, josta tuote on ostettu. limination des appareils mis au rebut par les mnages dans l'Union europenne Le symbole appos sur ce produit ou sur son emballage indique que ce produit ne doit pas tre jet avec les dchets mnagers ordinaires. Il est de votre responsabilit de mettre au rebut vos appareils en les dposant dans les centres de collecte publique dsigns pour le recyclage des quipements lectriques et lectroniques. La collecte et le recyclage de vos appareils mis au rebut indpendamment du reste des dchets contribue la prservation des ressources naturelles et garantit que ces appareils seront recycls dans le respect de la sant humaine et de l'environnement. Pour obtenir plus d'informations sur les centres de collecte et de recyclage des appareils mis au rebut, veuillez contacter les autorits locales de votre rgion, les services de collecte des ordures mnagres ou le magasin dans lequel vous avez achet ce produit. Entsorgung von Altgerten aus privaten Haushalten in der EU Das Symbol auf dem Produkt oder seiner Verpackung weist darauf hin, dass das Produkt nicht ber den normalen Hausmll entsorgt werden darf. Benutzer sind verpflichtet, die Altgerte an einer Rcknah-
mestelle fr Elektro- und Elektronik-Altgerte abzugeben. Die getrennte Sammlung und ordnungs-
geme Entsorgung Ihrer Altgerte trgt zur Erhaltung der natrlichen Ressourcen bei und garantiert eine Wiederverwertung, die die Gesundheit des Menschen und die Umwelt schtzt. Informationen dazu, wo Sie Rcknahmestellen fr Ihre Altgerte finden, erhalten Sie bei Ihrer Stadtverwaltung, den rtlichen Mllentsorgungsbetrieben oder im Geschft, in dem Sie das Gert erworben haben
. Kszlkek magnhztartsban trtn selejtezse az Eurpai Uni terletn A kszlken, illetve a kszlk csomagolsn lthat azonos szimblum annak jelzsre szolgl, hogy a kszlk a selejtezs sorn az egyb hztartsi hulladktl eltr mdon kezelend. A vsrl a hulladkk vlt kszlket kteles a kijellt gyjthelyre szlltani az elektromos s elektronikai kszlkek jrahasznostsa cljbl. A hulladkk vlt kszlkek selejtezskori begyjtse s jrahasznostsa hozzjrul a termszeti erforrsok megrzshez, valamint biztostja a selejtezett termkek krnyezetre s emberi egszsgre nzve biztonsgos feldolgozst. A begyjts pontos helyrl bvebb tjkoztatst a lakhelye szerint illetkes nkormnyzattl, az illetkes szemteltakart vllalattl, illetve a termket elrust helyen kaphat. D-2 R e c y c l e S t a t e m e n t s Recycle Statements Waste Electrical and Electronic Equipment (WEEE) Statements Smaltimento delle apparecchiature da parte di privati nel territorio dell'Unione Europea Questo simbolo presente sul prodotto o sulla sua confezione indica che il prodotto non pu essere smaltito insieme ai rifiuti domestici. responsabilit dell'utente smaltire le apparecchiature consegnan-
dole presso un punto di raccolta designato al riciclo e allo smaltimento di apparecchiature elettriche ed elettroniche. La raccolta differenziata e il corretto riciclo delle apparecchiature da smaltire permette di proteggere la salute degli individui e l'ecosistema. Per ulteriori informazioni relative ai punti di raccolta delle apparecchiature, contattare l'ente locale per lo smaltimento dei rifiuti, oppure il negozio presso il quale stato acquistato il prodotto. Nolietotu iekrtu izncinanas noteikumi lietotjiem Eiropas Savienbas privtajs mjsaimniecbs ds simbols uz izstrdjuma vai uz t iesaiojuma norda, ka o izstrdjumu nedrkst izmest kop ar citiem sadzves atkritumiem. Js atbildat par to, lai nolietots iekrtas tiktu nodotas specili iekrtotos punktos, kas paredzti izmantoto elektrisko un elektronisko iekrtu savkanai otrreizjai prstrdei. Atsevia nolietoto iekrtu savkana un otrreizj prstrde paldzs saglabt dabas resursus un garants, ka s iekrtas tiks otrreizji prstrdtas td veid, lai pasargtu vidi un cilvku veselbu. Lai uzzintu, kur nolietots iekrtas var izmest otrreizjai prstrdei, jvras savas dzves vietas pavaldb, sadzves atkritumu savkanas dienest vai veikal, kur izstrdjums tika nopirkts. Vartotoj i privai nam ki rangos atliek alinimas Europos Sjungoje is simbolis ant gaminio arba jo pakuots rodo, kad io gaminio alinti kartu su kitomis nam kio atliekomis negalima. alintinas rangos atliekas privalote pristatyti speciali surinkimo viet elektros ir elektronins rangos atliekoms perdirbti. Atskirai surenkamos ir perdirbamos alintinos rangos atliekos pads saugoti gamtinius iteklius ir utikrinti, kad jos bus perdirbtos tokiu bdu, kuris nekenkia moni sveikatai ir aplinkai. Jeigu norite suinoti daugiau apie tai, kur galima pristatyti perdirbtinas rangos atliekas, kreipkits savo seninij, nam kio atliek alinimo tarnyb arba parduotuv, kurioje sigijote gamin. Verwijdering van afgedankte apparatuur door priv-gebruikers in de Europese Unie Dit symbool op het product of de verpakking geeft aan dat dit product niet mag worden gedeponeerd bij het normale huishoudelijke afval. U bent zelf verantwoordelijk voor het inleveren van uw afgedankte apparatuur bij een inzamelingspunt voor het recyclen van oude elektrische en elektronische apparatuur. Door uw oude apparatuur apart aan te bieden en te recyclen, kunnen natuurlijke bronnen worden behouden en kan het materiaal worden hergebruikt op een manier waarmee de volksgezondheid en het milieu worden beschermd. Neem contact op met uw gemeente, het afvalinzamelingsbedrijf of de winkel waar u het product hebt gekocht voor meer informatie over inzamelingspunten waar u oude apparatuur kunt aanbieden voor recycling. Pozbywanie si zuytego sprztu przez uytkownikw w prywatnych gospodarstwach domowych w Unii Europejskiej Ten symbol na produkcie lub jego opakowaniu oznacza, e produktu nie wolno wyrzuca do zwykych pojemnikw na mieci. Obowizkiem uytkownika jest przekazanie zuytego sprztu do wyznaczonego punktu zbirki w celu recyklingu odpadw powstaych ze sprztu elektrycznego i elektronicznego. Osobna zbirka oraz recykling zuytego sprztu pomog w ochronie zasobw naturalnych i zapewni ponowne wprowadzenie go do obiegu w sposb chronicy zdrowie czowieka i rodowisko. Aby uzyska wicej informacji o tym, gdzie mona przekaza zuyty sprzt do recyklingu, naley si skontaktowa z urzdem miasta, zakadem gospodarki odpadami lub sklepem, w ktrym zakupiono produkt. D-3 s t n e m e t a t S e l c y c e R Recycle Statements Waste Electrical and Electronic Equipment (WEEE) Statements Descarte de Lixo Eltrico na Comunidade Europia Este smbolo encontrado no produto ou na embalagem indica que o produto no deve ser descartado no lixo domstico comum. responsabilidade do cliente descartar o material usado (lixo eltrico), encaminhando-o para um ponto de coleta para reciclagem. A coleta e a reciclagem seletivas desse tipo de lixo ajudaro a conservar as reservas naturais; sendo assim, a reciclagem ser feita de uma forma segura, protegendo o ambiente e a sade das pessoas. Para obter mais informaes sobre locais que reciclam esse tipo de material, entre em contato com o escritrio da HP em sua cidade, com o servio de coleta de lixo ou com a loja em que o produto foi adquirido. Likvidcia vyradench zariaden v domcnostiach v Eurpskej nii Symbol na vrobku alebo jeho balen oznauje, e dan vrobok sa nesmie likvidova s domovm odpadom. Povinnosou spotrebitea je odovzda vyraden zariadenie v zbernom mieste, ktor je uren na recyklciu vyradench elektrickch a elektronickch zariaden. Separovan zber a recyklcia vyradench zariaden prispieva k ochrane prrodnch zdrojov a zabezpeuje, e recyklcia sa vykonva spsobom chrniacim udsk zdravie a ivotn prostredie. Informcie o zbernch miestach na recyklciu vyradench zariaden vm poskytne miestne zastupitestvo, spolonos zabezpeujca odvoz domovho odpadu alebo obchod, v ktorom ste si vrobok zakpili. Odstranjevanje odsluene opreme uporabnikov v zasebnih gospodinjstvih v Evropski uniji Ta znak na izdelku ali njegovi embalai pomeni, da izdelka ne smete odvrei med gospodinjske odpadke. Nasprotno, odslueno opremo morate predati na zbiralie, pooblaeno za recikliranje odsluene elektrine in elektronske opreme. Loeno zbiranje in recikliranje odsluene opreme prispeva k ohranjanju naravnih virov in zagotavlja recikliranje te opreme na zdravju in okolju nekodljiv nain. Za podrobneje informacije o tem, kam lahko odpeljete odslueno opremo na recikliranje, se obrnite na pristojni organ, komunalno slubo ali trgovino, kjer ste izdelek kupili. Eliminacin de residuos de equipos elctricos y electrnicos por parte de usuarios particulares en la Unin Europea Este smbolo en el producto o en su envase indica que no debe eliminarse junto con los desperdicios generales de la casa. Es responsabilidad del usuario eliminar los residuos de este tipo depositndolos en un "punto limpio" para el reciclado de residuos elctricos y electrnicos. La recogida y el reciclado selectivos de los residuos de aparatos elctricos en el momento de su eliminacin contribuir a conservar los recursos naturales y a garantizar el reciclado de estos residuos de forma que se proteja el medio ambiente y la salud. Para obtener ms informacin sobre los puntos de recogida de residuos elctricos y electrnicos para reciclado, pngase en contacto con su ayuntamiento, con el servicio de eliminacin de residuos domsticos o con el establecimiento en el que adquiri el producto. Bortskaffande av avfallsprodukter frn anvndare i privathushll inom Europeiska Unionen Om den hr symbolen visas p produkten eller frpackningen betyder det att produkten inte fr slngas p samma stlle som hushllssopor. I stllet r det ditt ansvar att bortskaffa avfallet genom att verlmna det till ett uppsamlingsstlle avsett fr tervinning av avfall frn elektriska och elektroniska produkter. Separat insamling och tervinning av avfallet hjlper till att spara p vra naturresurser och gr att avfallet tervinns p ett stt som skyddar mnniskors hlsa och miljn. Kontakta ditt lokala kommunkontor, din nrmsta tervinningsstation fr hushllsavfall eller affren dr du kpte produkten fr att f mer information om var du kan lmna ditt avfall fr tervinning. D-4 Index Numerics 10/100Base-TX connections, length limitations 2-4 ports, cables used with 2-4 10/100Base-TX port location on access point 1-5 10/100-T LED 1-4 behaviors 1-4 A access point connecting to a power source 2-9 description 1-1 downloading new software 5-10 electrical specifications A-1 emmissions specifications A-2 environmental specifications A-1 external antenna options 4-2 features 1-8 included parts 2-1 LED descriptions 1-4 mounting on a wall 2-7 mounting on horizontal surface 2-9 physical specifications A-1 top panel description 1-3 access point operation verifying after installation 2-5 antennas external options 4-2 location on access point 1-5 auto MDI/MDI-X operation B-3 B back of access point 10/100Base-TX port 1-5 console port 1-6 description 1-5 lock 1-5 network port 1-6 power connector 1-6 basic access point configuration command line interface 3-2 I n d e x basic troubleshooting tips 5-1 blinking LEDs error indications 5-3 buttons Reset button 1-7 C cables 10/100Base-TX connections 2-4 connecting cables to the access point port 2-10 effects of non-standard cables 5-2 infrastructure requirements 2-4 length limitations 2-4 required types 2-4, 4-2 serial, for direct console connection 2-12 cables, twisted pair access point-to-computer connection B-3 access point-to-switch or hub connection B-4 category 3, 4, 5 B-2 cross-over cable pin-out B-4 MDI-X to MDI connections B-3 MDI-X to MDI-X connections B-4 pin-outs B-3 straight-through cable pin-out B-3 cables, twisted-pair wiring rules B-2 cables, twisted-pair connector pin-outs B-2 cabling infrastructure 2-4 CLI prompt, console displaying 2-13 command line interface key command descriptions 3-7 configuration command line interface 3-2 DHCP 3-2 IP address, manually 3-2 restoring factory defaults 5-8 connecting the access point to a power source 2-9 connector specifications A-2 Index 1 console checking messages during troubleshooting 5-6 command line interface 3-2 displaying the CLI prompt 2-13 features 2-11 how to connect in-band 2-11 how to connect out-of-band 2-11 serial cable connection 2-12 SSH access 3-10 Telnet access 3-9 terminal configuration 2-11 console port location on access point 1-51-6 cross-over cable pin-out B-4 x e d n I D DC power connector location on back of access point 1-5 description access point 1-1 back of access point 1-5 LEDs 1-4 top of access point 1-3 DHCP automatic access point configuration 3-2 for in-band access 2-11 diagnostic tests 5-6 checking the console messages 5-6 checking the LEDs 5-6 end-to-end connectivity 5-7 testing the access point only 5-6 testing twisted-pair cabling 5-7 downloading new access point software 5-10 E electrical specifications, access point A-1 EMC regulatory statements C-9 emmissions specifications, access point A-2 environmental specifications, access point A-1 external antenna options 4-2 features access point 1-8 console 2-11 front of access point Reset button 1-7 full-duplex fixed configuration effects on network connections 5-1 H horizontal surface mounting access point on 2-9 I in-band 3-1 in-band console access types of 2-11 included parts 2-1 installation connecting the access point to a power source 2-9 horizontal surface mounting 2-9 location considerations 2-4, 4-3 network cable requirements 2-4 precautions 2-3 site preparation 2-4 summary of steps 2-2 wall mounting 2-7 L LEDs 10/100-T 1-4 behavior during self test 2-6 blinking definition 1-4 checking during troubleshooting 5-6 descriptions of 1-4 error indications 5-3 location on access point 1-3 on access point 1-4 Power 1-4 behavior during self test 2-6 Self Test behavior during self test 2-6 F factory default configuration, restoring 5-8 Wireless 1-4 length limitations 10/100Base-TX connections 2-4 2 Index location for the access point, considerations 2-4, ports 4-3 lock location on access point 1-5 M MDI-X to MDI network cable B-3 MDI-X to MDI-X network cable B-4 mounting the access point on a horizontal surface 2-9 on a wall 2-7 precautions 2-7 N network cables 10/100Base-TX connections 2-4 required types 2-4 twisted-pair connector pin-outs B-2 twisted-pair, wiring rules B-2 network devices connecting to the access point 2-10 network ports connecting to 2-10 location on access point 1-6 standards compliance A-2 types of 2-4, 4-2 non-standard network cables, effects 5-2 O out-of-band console access 3-9 P parts, included with the access point 2-1 passwords deleting with the Reset button 3-8 if you lose the password 3-8 physical specifications, access point A-1 Ping test 5-7 pin-outs twisted-pair cables B-2 PoE power connector location on back of access point 1-5 port LEDs normal operation 2-6 I n d e x 10/100Base-TX, location on access point 1-5 connecting to 2-10 console 2-11 network connections 2-10 power connector 1-6 Power LED 1-4 behavior during factory default reset 5-9 behavior during self test 2-6 behaviors 1-4 location on access point 1-3 power source connecting the access point to 2-9 precautions mounting the access point 2-3 power requirements 2-3 preparing the installation site 2-4 Proactive Network tools diagnostics with 5-5 R recycle statements D-1 regulatory statements C-9 Reset button description 1-7 location on access point 1-7 to delete password protection 3-8 resetting the access point factory default reset 5-8 location of Reset button 1-7 troubleshooting procedure 5-6 S safety and regulatory statements C-1 safety specifications A-2 self test LED behavior during 2-6 Power LED behavior 2-6 Self Test LED behavior during self test 2-6 serial cable for direct console connection 2-12 sides of access point antennas 1-5 Index 3 specifications troubleshooting 5-1 connectors A-2 electrical A-1 emmissions A-2 environmental A-1 physical A-1 safety A-2 wireless A-3 SSH access to the console 3-10 straight-through cable pin-out B-3 summary of access point installation 2-2 of cables used with the access point 2-4, 4-2 T Telnet access to the console 3-9 terminal configuration 2-11 testing x e d n I access point operation 5-6 access point-to-device communications 5-7 checking the console messages 5-6 checking the LEDs 5-6 diagnostic tests 5-6 end-to-end communications 5-7 Ping test 5-7 twisted-pair cabling 5-7 tips for troubleshooting 5-1 top of access point 1-3 description 1-3 LEDs 1-4 topologies effects of improper topology 5-2 samples of 2-14 basic tips 5-1 checking the console messages 5-6 checking the LEDs 5-6 common network problems 5-1 connecting to fixed full-duplex devices 5-1 diagnostic tests 5-6 effects of improper topology 5-2 effects of non-standard cables 5-2 Ping test 5-7 Proactive Network tools 5-5 restoring factory default configuration 5-8 testing connections to other devices 5-7 testing end-to-end communications 5-7 testing the access point 5-6 testing the twisted-pair cables 5-7 twisted-pair cable access point-to-computer connection B-3 access point-to-switch or hub connection B-4 cross-over cable pin-out B-4 pin-outs B-2B-3 straight-through cable pin-out B-3 testing 5-7 V VCCI compliance C-13 VT-100 terminal serial cable connection for 2-12 W wall mounting access point on 2-7 warranty 1-ii wireless infrastructure topology with 2-15 wireless infrastructure for roaming clients topology with 2-16 Wireless LED 1-4 behaviors 1-4 wireless specifications A-3 wiring rules for twisted-pair cables B-2 4 Index
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2007-03-15 | 2412 ~ 2462 | DTS - Digital Transmission System | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2007-03-15
|
||||
1 | Applicant's complete, legal business name |
HP Inc.
|
||||
1 | FCC Registration Number (FRN) |
0025126541
|
||||
1 | Physical Address |
3390 East Harmony Road
|
||||
1 |
Fort Collins, Colorado 80528
|
|||||
1 |
United States
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
c******@curtis-straus.com
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
B94
|
||||
1 | Equipment Product Code |
RSVLC-0301B
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
R******** P******** T********
|
||||
1 | Title |
US Canada Technical Regulations
|
||||
1 | Telephone Number |
970-8********
|
||||
1 | Fax Number |
000-0********
|
||||
1 |
r******@hp.com
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
Advance Data Technology Corporation (Hsin Chu)
|
||||
1 | Name |
E**** L******
|
||||
1 | Physical Address |
81-1 Luliaoken, 9th Lin, Wulung Tsuen Chiunglin
|
||||
1 |
Hsinchu, 307
|
|||||
1 |
Taiwan
|
|||||
1 | Telephone Number |
886-3******** Extension:
|
||||
1 | Fax Number |
886-3********
|
||||
1 |
e******@adt.com.tw
|
|||||
app s | Non Technical Contact | |||||
1 | Firm Name |
Advance Data Technology Corporation
|
||||
1 | Name |
E****** L******
|
||||
1 | Physical Address |
81-1 Luliaoken, 9th Lin, Wulung Tsuen Chiunglin
|
||||
1 |
Hsinchu, 307
|
|||||
1 |
Taiwan
|
|||||
1 | Telephone Number |
886-3******** Extension:
|
||||
1 | Fax Number |
886-3********
|
||||
1 |
e******@adt.com.tw
|
|||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DTS - Digital Transmission System | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | ProCurve Wireless Access Point 420 NA, J8130B | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Output Power listed is conducted. This device must be professionally installed. Marketing to the General Public is prohibited. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. The use of other antenna requires a Class II Permissive Change filing. The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End -users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Bureau Veritas CPS (H.K.) Ltd. Taoyuan Branch
|
||||
1 | Name |
R**** C********
|
||||
1 | Telephone Number |
886-2********
|
||||
1 | Fax Number |
886-2********
|
||||
1 |
r******@tw.bureauveritas.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 2412.00000000 | 2462.00000000 | 0.2320000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC