FCC ID: B94HNC04PD Tablet

by: HP Inc. latest update: 2019-06-20 model: HNC04PD

One grant has been issued under this FCC ID on 06/20/2019 (this is one of one hundred and ninety-eight releases in 2019 for this grantee). Public details available include frequency information, internal & external photos, and manuals. some products also feature user submitted or linked drivers, warrantee terms, password defaults, instructions, & troubleshooting guides.
permalink for this FCC identifier
search for: Repair details
from iFixIt
Replacement
on Amazon
Trade-in? Recycling locations
eg is reader-supported. when you buy through links on our site, we may earn an affiliate commission.
|
|
|   
eg for Slack usage
app s submitted / available
1 Users Manual pdf June 12 2019 / December 18 2019
1 Users Manual pdf June 12 2019 / December 18 2019
1 Internal Photos pdf June 12 2019 / December 18 2019
1 External Photos pdf June 12 2019 / December 18 2019
1 Block Diagram Block Diagram pdf June 12 2019 confidential
1 Cover Letter(s) pdf December 06 2019
1 Cover Letter(s) pdf December 06 2019
1 Lab KDB Inquiry Operational Description pdf June 12 2019 confidential
1 Test Report pdf December 06 2019
1 Test Report pdf December 06 2019
1 Test Report pdf December 06 2019
1 Test Report pdf December 06 2019
1 Test Report pdf December 06 2019
1 Test Report pdf December 06 2019
1 Test Report pdf December 06 2019
1 Test Report pdf December 06 2019
1 Operational Description Operational Description pdf June 12 2019 confidential
1 Test Report pdf December 06 2019
1 Test Report pdf December 06 2019
1 Test Report pdf December 06 2019
1 Test Report pdf December 06 2019
1 Test Report pdf December 06 2019
1 Test Report pdf December 06 2019
1 Parts List Parts List/Tune Up Info pdf June 12 2019 confidential
1 Cover Letter(s) pdf December 06 2019
1 ID Label/Location Info pdf December 06 2019
1 Cover Letter(s) pdf December 06 2019
1 RF Exposure Info pdf December 06 2019
1 RF Exposure Info pdf December 06 2019
1 RF Exposure Info pdf December 06 2019
1 RF Exposure Info pdf December 06 2019
1 RF Exposure Info pdf December 06 2019
1 RF Exposure Info pdf December 06 2019
1 Test Setup Photos pdf June 12 2019 / December 18 2019
1 Schematics Schematics pdf June 12 2019 confidential
1 Test Setup Photos pdf June 12 2019 / December 18 2019
1 Tune Up Procedure Parts List/Tune Up Info pdf June 12 2019 confidential

frequency equipment class purpose
1 2019-06-20 1710.7 ~ 1754.3 PCB - PCS Licensed Transmitter Original Equipment

Application Forms

app s Applicant Information
1 Effective 2019-06-20
1 Applicant's complete, legal business name HP Inc.
1 FCC Registration Number (FRN) 0025126541
1 Physical Address 3390 East Harmony Road
1 Fort Collins, Colorado 80528
1 United States
app s TCB Information
1 TCB Application Email Address t******@siemic.com
1 TCB Scope B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
app s FCC ID
1 Grantee Code B94
1 Equipment Product Code HNC04PD
app s Person at the applicant's address to receive grant or for contact
1 Name R****** P**** T****
1 Title US Canada Technical Regulations
1 Telephone Number 970-8********
1 Fax Number 000-0********
1 E-mail r******@hp.com
app s Technical Contact
n/a
app s Non Technical Contact
n/a
app s Confidentiality (long or short term)
1 Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?:Yes
1 Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?:Yes
1 If so, specify the short-term confidentiality release date (MM/DD/YYYY format)12/18/2019
if no date is supplied, the release date will be set to 45 calendar days past the date of grant.
app s Cognitive Radio & Software Defined Radio, Class, etc
1 Is this application for software defined/cognitive radio authorization?No
1 Equipment ClassPCB - PCS Licensed Transmitter
1 Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant)Tablet
1 Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application?Yes
1 Modular Equipment TypeDoes not apply
1 Purpose / Application is forOriginal Equipment
1 Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization?No
1 Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization?No
1 Grant CommentsOutput power is ERP for Part 22 and Part 90, and EIRP for Part 24 and Part27. SAR compliance for body worn operating conditions is limited to the specific configuration tested for this filing. The highest reported SAR for body-worn exposure and simultaneous transmission exposure conditions is 1.37 W/kg and 1.57 W/kg respectively.
1 Is there an equipment authorization waiver associated with this application?No
1 If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded?No
app s Test Firm Name and Contact Information
1 Firm Name Bureau Veritas CPS(H.K.) Ltd., Taoyuan Branch
1 Name E******** L********
1 Telephone Number +886-********
1 Fax Number +886-********
1 E-mail e******@tw.bureauveritas.com
Equipment Specifications
Line Rule Parts Grant Notes Lower Frequency Upper Frequency Power Output Tolerance Emission Designator Microprocessor Number
1 1 22H 826.4 846.6 0.126 0.004 ppm 4M09F9W
1 2 22H 824.7 848.3 0.127 0.005 ppm 1M09G7D
1 3 22H 824.7 848.3 0.1 0.005 ppm 1M09W7D
1 4 22H 825.5 847.5 0.134 0.005 ppm 2M71G7D
1 5 22H 825.5 847.5 0.106 0.005 ppm 2M70W7D
1 6 22H 826.5 846.5 0.142 0.005 ppm 4M50G7D
1 7 22H 826.5 846.5 0.112 0.005 ppm 4M50W7D
1 8 22H 829 844 0.15 0.005 ppm 9M00G7D
1 9 22H 829 844 0.119 0.005 ppm 9M00W7D
1 1 22H 824.7 848.3 0.135 0.005 ppm 1M09G7D
1 11 22H 824.7 848.3 0.108 0.005 ppm 1M09W7D
1 12 22H 825.5 847.5 0.142 0.005 ppm 2M70G7D
1 13 22H 825.5 847.5 0.114 0.005 ppm 2M70W7D
1 14 22H 826.5 846.5 0.151 0.005 ppm 4M50G7D
1 15 22H 826.5 846.5 0.119 0.005 ppm 4M50W7D
1 16 22H 829 844 0.16 0.005 ppm 9M01G7D
1 17 22H 829 844 0.126 0.005 ppm 8M99W7D
1 18 22H 831.5 841.5 0.168 0.005 ppm 13M5G7D
1 19 22H 831.5 841.5 0.133 0.005 ppm 13M5W7D
1 2 24E 1852.4 1907.6 0.164 0.002 ppm 4M14F9W
1 21 24E 1850.7 1909.3 0.101 0.002 ppm 1M10G7D
1 22 24E 1850.7 1909.3 0.082 0.002 ppm 1M10W7D
1 23 24E 1851.5 1908.5 0.106 0.002 ppm 2M70G7D
1 24 24E 1851.5 1908.5 0.088 0.002 ppm 2M70W7D
1 25 24E 1852.5 1907.5 0.113 0.002 ppm 4M50G7D
1 26 24E 1852.5 1907.5 0.094 0.002 ppm 4M50W7D
1 27 24E 1855 1905 0.121 0.002 ppm 9M00G7D
1 28 24E 1855 1905 0.098 0.002 ppm 9M00W7D
1 29 24E 1857.5 1902.5 0.13 0.002 ppm 13M5G7D
1 3 24E 1857.5 1902.5 0.104 0.002 ppm 13M5W7D
1 31 24E 1860 1900 0.137 0.002 ppm 18M0G7D
1 32 24E 1860 1900 0.11 0.002 ppm 18M0W7D
1 33 27 2502.5 2567.5 0.065 0.002 ppm 4M51G7D
1 34 27 2502.5 2567.5 0.052 0.002 ppm 4M50W7D
1 35 27 2505 2565 0.069 0.001 ppm 8M99G7D
1 36 27 2505 2565 0.055 0.001 ppm 8M98W7D
1 37 27 2507.5 2562.5 0.073 0.002 ppm 13M5G7D
1 38 27 2507.5 2562.5 0.058 0.002 ppm 13M5W7D
1 39 27 2510 2560 0.077 0.002 ppm 18M0G7D
1 4 27 2510 2560 0.061 0.002 ppm 18M0W7D
1 41 27 2572.5 2617.5 0.101 0.001 ppm 4M50G7D
1 42 27 2572.5 2617.5 0.081 0.001 ppm 4M49W7D
1 43 27 2575 2615 0.106 0.002 ppm 8M99G7D
1 44 27 2575 2615 0.085 0.002 ppm 8M99W7D
1 45 27 2577.5 2612.5 0.113 0.001 ppm 13M5G7D
1 46 27 2577.5 2612.5 0.09 0.001 ppm 13M5W7D
1 47 27 2580 2610 0.12 0.002 ppm 18M0G7D
1 48 27 2580 2610 0.095 0.002 ppm 18M0W7D
1 49 27 2498.5 2687.5 0.076 0.002 ppm 4M50G7D
1 5 27 2498.5 2687.5 0.06 0.002 ppm 4M49W7D
1 51 27 2501 2685 0.08 0.002 ppm 8M99G7D
1 52 27 2501 2685 0.064 0.002 ppm 8M98W7D
1 53 27 2503.5 2682.5 0.085 0.001 ppm 13M5G7D
1 54 27 2503.5 2682.5 0.067 0.001 ppm 13M5W7D
1 55 27 2506 2680 0.09 0.001 ppm 18M0G7D
1 56 27 2506 2680 0.071 0.001 ppm 18M0W7D
1 57 27 2307.5 2312.5 0.071 0.002 ppm 4M50G7D
1 58 27 2307.5 2312.5 0.056 0.002 ppm 4M50W7D
1 59 27 2310 2310 0.074 0.002 ppm 8M99G7D
1 6 27 2310 2310 0.059 0.002 ppm 8M99W7D
1 61 27 1712.4 1752.6 0.207 0.002 ppm 4M08F9W
1 62 27 1710.7 1754.3 0.15 0.002 ppm 1M10G7D
1 63 27 1710.7 1754.3 0.119 0.002 ppm 1M10W7D
1 64 27 1711.5 1753.5 0.159 0.002 ppm 2M71G7D
1 65 27 1711.5 1753.5 0.125 0.002 ppm 2M71W7D
1 66 27 1712.5 1752.5 0.168 0.002 ppm 4M50G7D
1 67 27 1712.5 1752.5 0.134 0.002 ppm 4M50W7D
1 68 27 1715 1750 0.179 0.002 ppm 8M99G7D
1 69 27 1715 1750 0.144 0.002 ppm 9M00W7D
1 7 27 1717.5 1747.5 0.191 0.002 ppm 13M5G7D
1 71 27 1717.5 1747.5 0.151 0.002 ppm 13M5W7D
1 72 27 1720 1745 0.205 0.002 ppm 18M0G7D
1 73 27 1720 1745 0.161 0.002 ppm 18M0W7D
1 74 27 699.7 715.3 0.035 0.006 ppm 1M09G7D
1 75 27 699.7 715.3 0.027 0.006 ppm 1M10W7D
1 76 27 700.5 714.5 0.038 0.006 ppm 2M70G7D
1 77 27 700.5 714.5 0.028 0.006 ppm 2M70W7D
1 78 27 701.5 713.5 0.04 0.006 ppm 4M50G7D
1 79 27 701.5 713.5 0.03 0.006 ppm 4M50W7D
1 8 27 704 711 0.042 0.006 ppm 9M00G7D
1 81 27 704 711 0.032 0.006 ppm 8M99W7D
1 82 27 779.5 784.5 0.112 0.005 ppm 4M50G7D
1 83 27 779.5 784.5 0.085 0.005 ppm 4M50W7D
1 84 27 782 782 0.119 0.005 ppm 8M97G7D
1 85 27 782 782 0.091 0.004 ppm 8M97W7D
1 86 27 706.5 713.5 0.039 0.006 ppm 4M50G7D
1 87 27 706.5 713.5 0.032 0.006 ppm 4M50W7D
1 88 27 709 711 0.041 0.006 ppm 9M00G7D
1 89 27 709 711 0.033 0.006 ppm 9M00W7D
1 9 27 1710.7 1779.3 0.125 0.002 ppm 1M09G7D
1 91 27 1710.7 1779.3 0.098 0.002 ppm 1M10W7D
1 92 27 1711.5 1778.5 0.132 0.002 ppm 2M70G7D
1 93 27 1711.5 1778.5 0.104 0.002 ppm 2M71W7D
1 94 27 1712.5 1777.5 0.138 0.002 ppm 4M50G7D
1 95 27 1712.5 1777.5 0.109 0.002 ppm 4M50W7D
1 96 27 1715 1775 0.146 0.002 ppm 8M99G7D
1 97 27 1715 1775 0.116 0.002 ppm 8M99W7D
1 98 27 1717.5 1772.5 0.154 0.002 ppm 13M5G7D
1 99 27 1717.5 1772.5 0.122 0.002 ppm 13M5W7D
1 1 27 1720 1770 0.163 0.002 ppm 18M0G7D
1 101 27 1720 1770 0.129 0.002 ppm 18M0W7D
1 102 9 814.7 823.3 0.08 0.005 ppm 1M09G7D
1 103 9 814.7 823.3 0.062 0.005 ppm 1M10W7D
1 104 9 815.5 822.5 0.085 0.005 ppm 2M70G7D
1 105 9 815.5 822.5 0.069 0.005 ppm 2M70W7D
1 106 9 816.5 821.5 0.092 0.005 ppm 4M50G7D
1 107 9 816.5 821.5 0.073 0.005 ppm 4M50W7D
1 108 9 819 819 0.098 0.005 ppm 9M01G7D
1 109 9 819 819 0.077 0.005 ppm 9M00W7D

 

some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details

 

  This product uses the FCC Data API but is not endorsed or certified by the FCC