all | frequencies |
|
exhibits | applications |
---|---|---|---|---|
manual |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
Users Manual | Users Manual | 1016.26 KiB | ||||
1 | Cover Letter(s) | |||||||
1 | External Photos | |||||||
1 | Internal Photos | |||||||
1 | ID Label/Location Info | |||||||
1 | Cover Letter(s) | |||||||
1 | Test Report | |||||||
1 | Test Setup Photos |
1 | Users Manual | Users Manual | 1016.26 KiB |
i-PORT III Users Guide Version /NAE, operating under FCC 15.231(a) IDENTEC SOLUTIONS AG Millenniumspark 2 6890 Lustenau Austria Tel: +43 5577 87387 0 Fax: +43 5577 87387 15 www.identecsolutions.com i-PORT III Users Guide Proprietary Notice This Users Guide contains confidential and proprietary information of IDENTEC SOLUTIONS and, except for use by the authorized user, its employees, consultants and agents, may not be used by or disclosed to other parties in whole or in part without prior written authorization from IDENTEC SOLUTIONS. IDENTEC SOLUTIONS, Intelligent Long Range, ILR, ILR Enabled i-Q8, i-D, i-PORT, i-
CARD, i-LINKS and Solutions. Its in our name. are trademarks of IDENTEC SOLUTIONS, Inc. and/or IDENTEC SOLUTIONS AG. The mark IDENTEC SOLUTIONS is registered in the United States Patent Office. Copyright 2004 by IDENTEC SOLUTIONS. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means, photographic, electronic, mechanical or otherwise, or used in any information storage and retrieval system, without the prior written permission of IDENTEC SOLUTIONS. Disclaimer and Limitation of Liability IDENTEC SOLUTIONS AG and its affiliates, subsidiaries, officers, directors, employees and agents provide the information contained in this Users Guide on an as-is basis and do not make any express or implied warranties or representations with respect to such information including, without limitation, warranties as to non-infringement, reliability, fitness for a particular purpose, usefulness, completeness, accuracy or currentness. IDENTEC SOLUTIONS SHALL NOT IN ANY CIRCUMSTANCES BE LIABLE TO ANY PERSON FOR ANY SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES INCLUDING, WITHOUT LIMITATION, DAMAGES RESULTING FROM USE OF OR RELIANCE ON INFORMATION PRESENTED HEREIN, OR LOSS OF PROFITS OR REVENUES OR COSTS OF REPLACEMENT GOODS, EVEN IF INFORMED IN ADVANCE OF THE POSSIBILITY OF SUCH DAMAGES. Document ID: UG-i-PORT III NAE
-2-
i-PORT III Users Guide Radio Frequency Compliance Statement IDENTEC SOLUTIONS AG is the responsible party for the compliance of the following devices:
MODEL:
FCC ID:
CANADA:
i-PORT III OO4-IPORT3-NAE O2E-ILR-IPORT3 i-CARD O2E-ICARD-NA OO4-ILR-ICARD3 35381032231 i-D2 TAGS OO4-ILR-ID2 O2E-ILR-ID2NA 3538A12112 The user(s) of these products are cautioned to only use accessories and peripherals approved, in advance, by IDENTEC SOLUTIONS. The use of accessories and peripherals, other than those approved by IDENTEC SOLUTIONS or unauthorized changes to approved products, may void the compliance of these products and may result in the loss of the user(s) authority to operate the equipment. Operation is subject to the following conditions: (1) these devices may not cause harmful interference, and (2) these devices must accept any interference, including interference that may cause undesired operation of the device. Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. i-Qxx TAGS OO4-ILR-IQ32T OO4-ILR-IQR 35381021756A 35381021825 Important Note To comply with FCC radio frequency exposure compliance requirements, this device must be installed by an IDENTEC SOLUTIONS certified technician. When installing antennas, a 20 centimeter passing distance must be maintained from any body part of the user or nearby persons and the antenna. Document ID: UG-i-PORT III NAE
-3-
i-PORT III Users Guide Table of Contents 1.0 INTRODUCTION ...................................................................................................... 5 1.1 FUNDAMENTALS..................................................................................................................................................... 5 1.2 SYSTEM OVERVIEW .............................................................................................................................................. 5 2.0 I-PORT III .............................................................................................................. 7 2.1 INTRODUCTION...................................................................................................................................................... 7 2.2 PHYSICAL DESCRIPTION ..................................................................................................................................... 8 2.3 LED DISPLAYS ...................................................................................................................................................... 9 2.4 CABLE CONNECTIONS AND PLUG ALLOCATION .......................................................................................... 10 2.5 INTERFACES.......................................................................................................................................................... 12 2.6 PROTOCOLS .......................................................................................................................................................... 13 3.0 CONNECTING TO THE I-PORT................................................................................ 14 3.1 DEFAULT SETTINGS............................................................................................................................................ 14 3.2 NETWORK CONNECTION ................................................................................................................................... 14 3.3 SERIAL CONNECTION......................................................................................................................................... 15 4.0 WEB INTERFACE ................................................................................................... 19 4.1 HOME...................................................................................................................................................................... 19 4.2 STATUS.................................................................................................................................................................. 20 4.3 PROCESSOR ACTIVITY ....................................................................................................................................... 20 4.4 CONFIGURATION ................................................................................................................................................. 21 4.5 GENERAL ............................................................................................................................................................... 26 5.0 VIEWING TAGS ..................................................................................................... 27 5.1 I-LINKS VIEWER INTERFACE ............................................................................................................................. 27 5.2 DEBUG INTERFACE ............................................................................................................................................... 27 6.0 OPERATING RESTRICTIONS.................................................................................. 28 6.1 TRIGGERED OPERATION, FCC 15.231 (A) ........................................................................................................ 28 7.0 TECHNICAL SPECIFICATONS................................................................................. 29 8.0 TROUBLESHOOTING.............................................................................................. 31 9.0 CONTACT INFORMATION ...................................................................................... 33 APPENDIX A CONFIGURATION PARAMETERS ............................................................. 34 Document ID: UG-i-PORT III NAE
-4-
i-PORT III Users Guide 1.0 Introduction 1.1 Fundamentals IDENTEC SOLUTIONS ILR (Intelligent Long Range) technology is the next generation of long range RFID
(Radio Frequency Identification). The objective is wireless and automated data collection over large distances. HOW RFID WORKS Data is transmitted via high frequency radio waves between a tag and an interrogator. Information stored on the tag can be read and modified. Data can be exchanged over large distances, even in extreme environmental conditions such as dust, dirt, paint or oil. The core element of the system is the active ILR tag, which can communicate large amounts of data (up to 32 kBytes) at a rapid rate of transmission over very large distances (up to 100 meters). A sophisticated anti-collision handling algorithm enables the interrogator (i-PORT) to record data simultaneously from hundreds of tags within seconds. Connection of the interrogator to a host computer system enables global data accessibility via a variety of software platforms (Internet). CHARACTERISTICS OF ILR:
UHF Frequency (868 / 915 MHz) Variable read range from just a few meters up to 100 meters Highly visible LED pick-by-light (optional) Anti-collision process and multi-tag handling Large read and write range of 30 meters (optional up to 100 meters) Temperature monitoring and recording (optional) Large storage capacity (8 kB; up to 32 kB) Long battery lifetime (up to 6 years) 1.2 System Overview IDENTEC SOLUTIONS ILR System consists of 4 main components:
Active tags (also called transponders) with internal power supply, which are used to identify goods or to store data and histories Interrogator (also called readers i-PORT; fixed-mounted) and handheld devices (mobile), which exchange information with the tags and host computer systems Various antenna types/characteristics for different applications A central computer system as basis for control and monitoring Document ID: UG-i-PORT III NAE
-5-
i-PORT III Users Guide ILR System Components:
Tags from the i-Q and i-D2 series monitor, record and transmit stored data over large distances. The high data transmission rate ensures optimal communication. Data can be written to or read from the tags by means of the fixed interrogator (i-PORT) and then transmitted via LAN (or WLAN, modem, etc.) to a host computer network. Application software as well as all IDENTEC SOLUTIONS products can be seamlessly integrated into existing software environments by means of standard interfaces (TCP/IP, FTP, HTTP, etc.) Data can also be written to or read from tags at a distance of up to 10 meters by a mobile handheld interrogator. Thanks to the i-CARD, an RFID interrogator in a PC Card format (standard PCMCIA Type II card), a flexible and adaptable, practically hardware independent application is created. The i-CARD can be used in third-party handheld devices from a variety of manufacturers (Symbol, LXE, Latschbacher, Teklogix) Document ID: UG-i-PORT III NAE
-6-
i-PORT III Users Guide 2.0 i-PORT III 2.1 Introduction The i-PORT III is the next generation of IDENTEC SOLUTIONS ILR interrogators. ILR technology allows automated, wireless data collection. Up to 4 antennas (plus one extra send antenna) can be connected to the i-PORT III. The i-PORT III is delivered complete with standard software, which offers the user a variety of options:
Communication with ILR tags (i-Q only) Simultaneous operation with up to 4 antennas
(send/receive), with the option of a fifth antenna
(send) Communication with host computer systems via Ethernet or RS232 interfaces Connection to external devices such as modem or GSM via serial interface (optional) I/O control (4 relays, 4 digital inputs) Data processing (event messages, in/out, etc.) Configuration by means of web-interface (remote maintenance) The i-PORT III has a Real-Time Operating System (RTOS: Thread X) and an internal Real-Time Clock (RTC), which permit an exact time allocation of the data. Up to 2048 data messages can be stored temporarily. Document ID: UG-i-PORT III NAE
-7-
i-PORT III Users Guide 2.2 Physical Description 180 1 0 2 a 1 1 2 7
, 8 3 2 5
, 0 2 0 9 5 21,9 The amount of space required to mount the i-PORT is 200 x 250 x 60 mm (B x H x W). The i-PORT weighs approx. 2 kg. A socket wrench (size 3) is required to open the i-PORT. Use the rubber grommet with hole to feed cables through the housing to the outside (cable diameter 4.75 mm to 6 mm); seal the unused feed-through with the blind plugs. These feed-through are intended for RG58 (antenna), Ethernet or serial cables. For power supply, use the PG fitting [screw joint]. If plugs [jacks, connectors] do not fit through the grommet (i.e. Ethernet), you may cut through the grommet (Note:
impermeability!). Enclosure rating IP64 (total protection from water sprayed from all directions) is thus achieved. If greater enclosure rating is required, the i-PORT must be placed in an additional housing. Document ID: UG-i-PORT III NAE
-8-
i-PORT III Users Guide 2.3 LED Displays POWER: Lights up as soon as power is applied to the i-PORT RUN:
HOST:
ERROR: Lights up as soon as an error occurs (see section: Troubleshooting) Blinks (every 2 seconds) as soon as the i-PORT has booted (approx. 30 seconds) Lights up as soon as a host is connected to the i-PORT Status LEDs:
COM LEDs:
INPUT LEDs:
ANTENNA LEDs:
RX:
TX:
1-4:
1-4:
W:
OUTPUT LEDs:
1-4:
Lights up when the i-PORT receives data on serial interface Lights up when the i-PORT sends data on serial interface Light up when Inputs 1-4 are set (Connection to Ground) Light up when there is activity at corresponding Antennas 1-4 Green: Antenna is sending Red:
Lights up when there is activity at the Wake-up Antenna Antenna is receiving Light up when the corresponding Outputs 1-4 are set Document ID: UG-i-PORT III NAE
-9-
i-PORT III Users Guide 2.4 Cable Connections and Plug Allocation ANT 1 ANT 2 ANT 3 ANT 4 ANT W V 0 3
. 0 1
D N G SUPPLY V 0 3
. 0 1
1 N 2 N I I INPUT D N G V 0 3
. 0 1
3 N 4 N I I INPUT D N G RS 232 10/100 BASE-T OUTPUT 1 2 3 4 LNK ACT SMA socket, send and receive antennas SMA socket, send antenna ONLY (WakeUp Antenna) I I
. 1 N 2 N 0 1
0 1
V 0 3 V 0 3 D N G D N G V 0 3
. INPUT ANT1-4 ANT W Antenna jacks:
Terminal Block 1:
SUPPLY Terminal Block 2:
Terminal Block 3:
Terminal Block 4:
4 RS-232 Serial Interface (Male):
Ethernet interface (10 and 100 Mbit/s) 10/100 BASE-T 1 COM 2 3 COM 4 OUTPUT INPUT RS 232 2 3 D N G 0 1
4 N 3 N LNK ACT 1
. I I
+10..30V Power Supply (+10-30V DC, min 2A) GND Power Supply Ground
+10..30V Power supply for optional inputs (max. 4W) IN1 IN2 GND Sensor 1 Connection Sensor 2 Connection Ground connection for optional inputs
+10..30V Power supply for optional inputs (max. 4W) IN3 IN4 GND Sensor 3 Connection Sensor 4 Connection Ground connection for optional inputs Normally open Output 1 (Relay) Ground from Relays 1 and 2 Normally open Output 2 (Relay) Normally open Output 3 (Relay) Ground from Relays 3 and 4 Normally open Output 4 (Relay) RS 232 Communication Speed: up to 115 kb/s Male DB-9 10/100 Communication Speed: up to 100 Mbits/s RJ-45 Modular Jack Supply Supply Input Input Input Input Input Input Input Input Output Output Output Output Output Output Document ID: UG-i-PORT III NAE
-10-
i-PORT III Users Guide 2.4.1 Input Connection The i-PORT has the ability to use external sensors as triggers, that is, scans or event messages can be activated by events. External sensors such as photo sensors, motion detectors, etc. (with NPN-output) can be used. The input is set by connecting it to Ground. The sensor can be managed from the i-PORT; power is available from the i-PORTs power supply (see below). Maximum resistance across Ground is 560 Ohms, in order to set the input. VB IN1 IN2 GND VB IN3 IN4 GND VB GND 10..30V 2.4.2 Output Connection The i-PORT also has the ability to intervene in processes. Lamps, sirens, gates, etc. can be switched using the relays. OUT1 COM OUT2 OUT3 COM OUT4 The maximum breaking capacity of the potential-free relay contacts is 30W (DC) and 62.5 VA (AC). Contact load is 1A/30VDC and 0.5A/125VAC. The Out and Com clamps are connected when the relays are switched on. Document ID: UG-i-PORT III NAE
-11-
i-PORT III Users Guide 2.5 Interfaces 2.5.1 Serial Interface RS232:
Pin Name Description 1 2 3 4 5 6 7 8 9 CD RXD TXD DTR GND DSR RTS CTS RI Carrier Detect Receive Data Transmit Data Data Terminal Ready System Ground Data Set Ready Request to Send Clear to Send Ring Indicator Rate of transmission: 9.6 kbit/s (Boot dialog, fix) Rate of transmission: 1.2 to 115.2 kbit/s (Protocol, configurable) For the communication with a Host-PC (e.g. Serial Host or Boot Dialog) only RXD, TXD and GND is needed. Other contacts are optional in use for modems or GSM-device. GPS Device:
A standard protocol (GPRMC) has been implemented. All devices (i.e. Garmin GPS 35) that work with this protocol are suitable for operation with the i-PORT. GSM Device:
It is currently possible to use GSM-Modems from Siemens (TC 35 or MC 35). Full functionality of the i-PORT is available when using these modems because of the implementation of an RAS Server. This means that it is also possible to configure the i-PORT over a browser by dialed-up GSM. Some modems need a permanent connection between Pin 4 (DTR) and Pin 6 (DSR) to achieve full functionality. Document ID: UG-i-PORT III NAE
-12-
i-PORT III Users Guide 2.5.2 Ethernet Interface:
Pin 1 2 3 4 5 6 7 8 Name TX+
TX-
RX+
nc nc RX-
nc nc Description Transmit Data +
Transmit Data -
Receive Data +
Receive Data -
Rate of transmission: 10 Mbit/s / 100 Mbit/s Protocols: TCP/IP, FTP, Telnet, HTTP, UDP, SNMP, SNTP Ports:
Debug Port Communication Port Synchronization Port WLAN:
It is possible to establish a WLAN connection by means of a wireless bridge. 2.6 Protocols 7090 7070 7070 for Debug data for communication (commands, messages) to synchronize i-PORTs The protocol used by the i-PORT is an ASCII protocol. The same protocol is used on the serial interface as well as on the Ethernet interface (Port 7070). The protocol allows a host computer to take control of the process or of the i-PORT. It is possible to execute scans, to read or write data, to start temperature logs etc. on command. For more information about the protocol, please refer to the i-PORT Communication Protocol. Document ID: UG-i-PORT III NAE
-13-
i-PORT III Users Guide 3.0 Connecting to the i-PORT 3.1 Default Settings The i-PORT is supplied with the following standard settings:
IP Address: 192.168.2.244 Subnet Mask: 255.255.255.0 User Name: user Password: identec 3.2 Network Connection If the i-PORT has an IP address of 192.168.2.244, then the PC you are using to connect to the i-
PORT with should have an IP address in the range 192.168.2.xxx. Direct Connection:
Connect the i-PORT directly to the network connection on your PC, laptop, etc. using a crossover network cable. Ensure that the PCs IP address lies in the same subnet as that of the i-PORT. Network Connection:
Connect the i-PORT to the network with a standard patch network cable. To test the connection to the i-PORT, open a Command Prompt window and type in the command
<ping 192.168.2.244>. You should receive a ping response from the i-PORT. After successfully testing the i-PORT connection, you can start your browser and open the i-PORT web interface. To do this, enter in the i-PORT IP address into the address field of the web browser ex. http://192.168.2.244. In doing this, you will get to the Home page of the i-PORT. Several sub-menus are available to you for configuration and for testing purposes. Descriptions of the menus and parameters are contained in Section 4.0. Document ID: UG-i-PORT III NAE
-14-
i-PORT III Users Guide 3.3 Serial Connection It is possible to change basic settings such as IP address, passwords, etc. via the serial interface. To accomplish this, the i-PORT has to be connected via the serial interface to a PC, (with a null-modem serial cable). Next, start a terminal program (HyperTerminal, GanTerm, etc.) with the following settings:
Bits per second: 9600 Data bits:
Parity:
Stop bits:
Protocol:
8 None 1 None Document ID: UG-i-PORT III NAE
-15-
i-PORT III Users Guide Power off, then power on the i-PORT after there is a connection. Boot information appears on the screen and you must press the ESCAPE key within 5 seconds to change the current settings. You will be prompted with the following:
Press A to Accept, M to Modify, D to set to Factory Default. By pressing M you will now have the ability to change various standard settings:
Document ID: UG-i-PORT III NAE
-16-
i-PORT III Users Guide 3.3.1 Boot Menu Descriptions PROJECT AND LOCATION INFO:
Location User Assigned Document ID: UG-i-PORT III NAE
-17-
i-PORT III Users Guide Project Yes/No User Assigned Enable Custom Application Disable Password Change Password Yes/No Change Password PASSWORD SETTINGS:
CUSTOM APPLICATION SETTINGS:
NETWORK INTERFACE PARAMETERS:
HARDWARE PARAMETERS:
Baud Rate Boot Delay After the changes have been made and confirmed, the i-PORT will boot up and go into the designated mode. You can write down the new IP address in the designated spot inside the i-PORT door. Yes/No Static IP (if DHCP is Disabled) Subnet mask Gateway IP if needed Necessary for Modem Necessary for Modem Data transmission 1.2 to 115.2 kbit/s Amount of time to access the Boot menu DHCP Enabled IP Address Subnet Mask Gateway Com1 PPP IP Com1 PPP Peer IP Document ID: UG-i-PORT III NAE
-18-
i-PORT III Users Guide 4.0 Web Interface The following highlights the different menu options:
4.1 Home The Home page displays information about:
Application Type: Host or i-LINKS Agent Version numbers: Software, Hardware, and Protocol CPU-board Serial Host IP Address: This will display the IP address of the device that you are using to i-PORT Temperature i-PORT Input Power i-PORT IP Address communicate with the i-PORT. Project: Entered by the user on the General Page. Location: Entered by the user on the General Page. Date/Time: The current date and time that the i-PORT is using (usually in UTC). Uptime: The amount of time that the i-PORT has been running since it was powered. Document ID: UG-i-PORT III NAE
-19-
i-PORT III Users Guide 4.2 Status The Status page contains status information, which may be required in case maintenance is needed, is available on this page. 4.3 Processor Activity The Processor Activity page displays information about the running threads on the systems. The information on this page may be useful to technical support when trouble-shooting. This page is automatically updated every 5 seconds. Document ID: UG-i-PORT III NAE
-20-
i-PORT III Users Guide 4.4 Configuration Document ID: UG-i-PORT III NAE
-21-
i-PORT III Users Guide i-PORT General Standard i-PORT settings such as type, external devices etc. i-PORT Type 2 possibilities: Host and Client Enter the i-PORT type here. i-PORT Main ID i-PORT SubID i-PORT SerDevice i-PORT identifier for event messages (Area ID) i-PORT identifier for event messages (Area SubID) 4 possibilities: No Device, GPS, Modem, and Serl Host (Restart after changes!) No Device means the serial port is not used. There is an option to connect a GPS device (i.e. Garmin) or a GSM Modem (i.e. Siemens TC35). Furthermore, the i-PORT can be controlled serially (Serl Host). Host Connection These are settings used if the i-PORT is to be connected to a host computer (Client Mode). Host IPAddr Host Port Host TimeOut Host SyncInterval Host computer IP address Host computer port i-PORT timeout Interval for synchronizing i-PORT time (if a GPS device is connected, time is synchronized with GPS time) Interval for sending messages to host computer Host SendInterval Host ListSize Debug Config Settings for the Debug output (Port 7090). If a check-box is selected then that parameter is valid. Debug HostMirror When this value is reached, the list is sent to the host computer Output on Debug Port of all data that is exchanged on the Host Interface (serial or Ethernet). Debug TagList The amount of time which a tag list is outputted on the Debug Port (0 means no output) Output of tag list after sequence execution. Output of newly-recognized tags (Note: must be less than the Inhibit Time!) Debug NewTag Debug ScanTag Synchronization Note: Not implemented with i-LINKS Settings for when several i-PORTs are located in a small space, necessitating synchronization. After marking the check-box, the IPs of the other i-PORTs can be entered into the designated field. Master IP Comm Timeout Token Timeout Timeout for synchronization (when registering a slave at the master) Timeout for synchronization (Timeout for Token signal) Enter IP addresses of the neighboring i-PORTs Document ID: UG-i-PORT III NAE
-22-
i-PORT III Users Guide Scan i-PORT settings for the scan process. Mode 3 possibilities: Host Only, Continuous and Input 1 Host Only means that the i-PORT waits for commands, processes them, and is otherwise inactive. Continuous means that the i-PORT performs continuous scans. Input 1 means that scans are triggered by Triggerinput 1 Slot Select Number of slots in which tags can answer; this is part of the anti-collision process. Set at least double the amount of slots as the maximum number of tags that can be located in the zone at one time. The elapsed time per slot in which tags can answer is 1.2 ms. Num of Scans Input1 Mode: Number of sequences executed by the i-PORT after Input1 again becomes inactive. In Test Mode, this is also the number of scans. Scan Pause Pause inserted by i-PORT after each sequence. Data communication i-PORT settings for tag communications (also dependent on the Inhibit Time!) Data communication Blink:
Setting to cause tags entering the zone to blink (dependent on Inhibit Time!) Blink If this check box is marked off, each newly-recognized tag will blink. If Inhibit Time is activated (>0), it must first elapse for the tag (reentering the zone) to blink again. Number of maximum attempts to read data Additional output power required for read process Data communication Read Data:
Settings for i-PORT to read data from tags (mark check box) Power Boost Retries Start Address Num of Bytes Data communication Power Saving:
Settings for i-PORT to place tags into Sleep Mode (mark check box) Mode 3 possibilities: Sleep, Mute or Both The tag start address where the i-PORT will begin to read tag data. Number of bytes to read from the tag beginning from the Start Address Sleep, Mute, Both (i-Q): All 3 settings have the same effect for i-Q tags (sleep). For this duration, the tags can no longer be communicated with (also from other i-PORTs). After this time span has expired, the tags become available again. Otherwise, the tag returns to normal mode, as it likewise does if it receives a signal from a different i-PORT. Mute (i-D2): Tags receive a signal, but give no answer for the duration of the mute. If the tag receives a renewed signal from the same i-PORT, the time will be re-triggered. Both (i-D2): Combination of Sleep and Mute!
Document ID: UG-i-PORT III NAE
-23-
i-PORT III Users Guide Duration The amount of time to put a tag into Sleep/Mute mode. The maximum sleep time for i-D2 is 6 seconds and 256 seconds for i-Q. Detection i-PORT settings which determine which tag types to interrogate and how. Tag Type 3 Options: i-Q8/32, i-D2 and Both Depends on which tags need to be interrogated. Note: i-D2 and Both are not working in this version operating under FCC 15.231!
Mode 3 Options: Normal, Max. Level and In/Out Normal: Tag is reported when it enters the read zone. Max. Level: Report the tag with its largest recorded field strength during the detection time interval. In/Out: Report the direction tag Orientation recognition activated (Antenna 1In, Antenna 2Out, Antenna 3In, Antenna 4Out) Detection Time Max. Level Mode: The window size used to determine the largest recorded field Inhibit Time strength. (Note: must be less than the Inhibit Time) In/Out Mode: The window size used to determine the tag direction. (Note: must be less than the Inhibit Time) If a previously interrogated tag leaves the zone for longer than the Inhibit Time, it will be recognized as a new tag when it reenters the zone. If the tag reenters the zone before expiration of the Inhibit Time, this time is reset as if the tag had never left the zone Event message i-PORT settings to determine when an event message is to be sent and how it should look. Event message - Event reason:
A tag or an input can serve as a trigger for an event Tag 3 Options: Enter, Leave or Enter and Leave A message is generated when the tag enters the zone, when it leaves the zone, or both when it enters AND when it leaves the zone. Input 4 Options: None, Rising Edge, Falling Edge or Changing A message is sent when the Input detects either a rising edge, a falling edge, or when any change at the Input is detected. Use None if nothing is attached to the Inputs. Message content Each message can contain up to 4 additional pieces of information. By marking the check box, the corresponding information is added to the message (in addition to the Tag ID): i-PORT ID, Time/Date, Tag Status and Field Strength. Antenna settings:
i-PORT settings for the antennas, power outputs, etc. Enable Scan Enable By marking the check box, the corresponding antenna is activated By marking the check box, the corresponding antenna is also able to send Document ID: UG-i-PORT III NAE
-24-
i-PORT III Users Guide i-Q TxPower i-D TxPower Rx Threshold Sensitivity Cable Loss Synch Group Power setting for i-Q tags at time of scan (send) Power setting for i-D2 tags at time of scan (send) Note: This settings have no function in this version operating under FCC 15.231!
Threshold (field strength of tag signal) required for tag recognition i-PORT receiver mode; this means that the Rx Threshold reaches 60dBm in low sensitivity mode and 90dBm in high sensitivity mode Differences in the various antenna types and cable lengths can be adjusted here (A calculation example is shown below.) Antennas can be separated in different groups for synchronizing different i-
PORTs Calculation examples for Cable Loss field:
Coaxial cable RG58 has a loss of approximately 0.6dB/m (at 900 MHz). LMR-400 has a loss of approximately 0.06dB/m. Loss across an SMA connector is approximately 0.2dB. Loss across an N-to-SMA adapter (required to connect LMR-400 to the I-PORT) is 0.4dB. 1) 5dB gain antenna, 3-meter pigtail RG58 cable: (Antenna Gain Cable Loss - SMA Connector Loss) =
(5dB 3m x 0.6 dB/m 0.2 dB) = 3.0 dB 2) 5dB gain antenna with N-connector on the antenna, 100-meter LMR-400 cable plus 2 -meter RG58 adapter cable: (Antenna Gain N-connector Loss LMR-400 Cable Loss N/SMA Adapter Loss RG58 Cable Loss SMA Connector Loss) = (5dB 0.2dB - 100m x 0.06dB/m 0.4dB 2 x 0.6dB/m 0.2dB) = +3.0 dB Valid values for each parameter in the i-PORT Configuration section can be obtained from Appendix A. Document ID: UG-i-PORT III NAE
-25-
i-PORT III Users Guide 4.5 General With this menu, you can change the network settings of the i-PORT. Simply enter the new values in the appropriate fields and click on the SET&REBOOT button. The i-PORT will then reboot with the new network settings. You can write down the new IP address in the designated spot inside the i-PORT door. Document ID: UG-i-PORT III NAE
-26-
i-PORT III Users Guide 5.0 Viewing Tags 5.1 i-LINKS Viewer Interface i-LINKS Viewer is a GUI for viewing tag reads from i-PORT III while running the i-LINKS Agent. Please refer to the i-LINKS Viewer User Guide for instructions on how to use and setup i-LINKS Viewer. 5.2 Debug Interface i-PORT III has a debug interface in which you can view tag reads through a terminal window. Typical uses for the debug interface is to test the i-PORT functionality without running the i-LINKS Agent. Things to Note Prior to Using the Debug Interface If the i-PORT is running an Agent make sure to backup your current settings and scripts as these will be lost when using the debug option. In order to connect to the debug port of the i-PORT you must set the Custom Application switch to OFF. 5.2.1 Viewing Debug Output Create a Telnet connection to the debug port (Default IP-Address: 192.168.2.244, Port: 7090). From a command prompt type in telnet 192.168.2.244 7090. Debug information showing the result of each scan will then be displayed on the monitor.
# Tags in List Tag ID Field Strength Antenna 1 Field Strength Antenna 2 Session Setup
(active) Read data
(inactive) Data
(inactive)
-27-
Document ID: UG-i-PORT III NAE i-PORT III Users Guide 6.0 Operating Restrictions 6.1 Triggered Operation, FCC 15.231 (a) If the i-PORT III will be used for triggered operation according to FCC 47 CFR 15.231 (a) the following restrictions have to be obeyed:
- Maximum radiated power must not exceed 3dBm (2mW EIRP), including all cable losses and antenna gain. To calculate this radiated power from the settings of the i-PORT please see paragraph 4.4 above. Length of transmission has to be limited to 5 seconds. This can safely be done by reading no more than 4kB of data from a tag.
Please note that this are functions of both the driving software and the setup of the device. In order to avoid any violations of the FCC rules the responsible System Integrator and his trained installation personnel has to implement this in the application software and use the password mechanism built into the i-PORT. This will prevent the user to adjust any settings which are not allowed. This system is only authorized for professional installation. Please note that the output power and scan pause can be set in the configuration menu. In order to avoid any violations of the FCC rules the responsible System Integrator and his trained installation personnel has to use the password mechanism built into the i-PORT. This will prevent the user to adjust any settings which are not allowed. Document ID: UG-i-PORT III NAE
-28-
i-PORT III Users Guide ILR i-Q Tags 7.0 Technical Specificatons ILR Parameters Compatibility Read range (adjustable) Write range (adjustable) Max. response time (single tag) Read rate (ID only) Read rate 128 bit data Multi-tag-handling
(simultaneous) RF Interface Frequency Certification RF rate of transmission Number of antennas Antenna transmitters Antenna receivers Antenna control User Interface Ethernet interface Protocols Serial interface Rate of transmission, serial Input control Output control Status signals CPU Operating system Program memory Data memory Configuration memory Time base ILR i-Q Tag 100m (300 ft) 100m (300 ft)
< 150 ms 100 tags/s 35 tags/s Up to 2,000 tags 868 MHz Band FCC, part 15 (US) EN 330 220 (EU) i-Q 115.2 kbit/s, 115.2 kbit/s (Rx) 5 (4 read/write + 1 wakeup) 5 Output power: up to 3 dBm adjustable 4 Sensitivity: up to -90 dBm adjustable Independent antennas, simultaneous operation (receive) 10 Mbit/s / 100 Mbit/s TCP/IP: FTP, HTTP, Debug Port 7090, Communication Port 7070 UDP: SNMP, SNTP, Synchronization Port 7080 RS 232 1.2 to 115.2 kbit/s 4 digital inputs for process synchronization Active when grounded, Rmax=560 Ohm 4 relay outputs for process control max. breaking capacity: 30W (DC); 62.5VA (AC) max. contact load: 1A at 30VDC, 0.5A at 125VAC 19 status LEDs (for service and installation) RTOS (Real Time Operating System) Thread X 2 MB Flash 8 MB DRAM 128 KB SRAM 8 KB EEPROM Battery-backed Real Time Clock (RTC) Document ID: UG-i-PORT III NAE
-29-
i-PORT III Users Guide Electrical Data Input voltage Input power Standards / safety Environmental Conditions Operating temperature Storage temperature Humidity Physical Data Dimensions Enclosure Mass Mounting Enclosure rating 10 30 VDC 7.5 W minimum CE and EN 330 220 0C to +50C optional 30C to +70C
-40C to +80C 90%, non-condensing 211mm x 190mm x 58mm Aluminum, anodized 1.9 kg 4 mounting holes, diameter 5mm IP 64 Document ID: UG-i-PORT III NAE
-30-
i-PORT III Users Guide 8.0 Troubleshooting 1) If the Error LED lights up during operation, a system error has occurred (exception). First execute a cold start (interrupt the power supply) and observe the system. If the error occurs again, contact IDENTEC SOLUTIONS. 2) For other problems, follow the procedures as outlined below. Problem No functionality after turning on the power supply Possible Cause Procedure No power
- Measure the blocks, check power supply unit
- If no voltage at terminal voltage at the terminal blocks
- Measure directly at the outlet for a power adaptor
- For a switching power supply, measure voltage at both input and output sides Wrong IP address - Double-check the i-PORT No communication between i-PORT and network (PC) i.e. cannot ping i-PORT IP address. Default-IP:
192.168.2.244
- Perform a ping on the IP
(see Configuration, Settings)
- If this is unsuccessful, start the Boot menu and check/change the IP
- Double-check the subnet mask
- Direct connection i-PORT /
Host: cross-over network cable
- i-PORT integrated into network: network cable
- Do optical check on cable
- Check ARP-cache
- Check if the antennas are fastened correctly i-PORT IP and Host IP are not in the same subnet Wrong network cable Defective network cable Wrong MAC-
address in ARP-
cache Antennas are not connected Tags are not being recognized Antennas are not being triggered
- Check if antenna LEDs light up (LED: ANT1, ANT2, ANT3, ANT4, W) Solution Change power supply unit, if necessary Change the IP address if necessary and try to ping the i-PORT Change the subnet mask Change the network cable Change network cable Clear ARP-cache and try to ping the i-PORT again Fasten antenna cables to the designated sites. Use torque wrench, if available, otherwise tighten the SMA plug lightly. Activate the corresponding antenna (see Configuration) Document ID: UG-i-PORT III NAE
-31-
i-PORT III Users Guide Antenna is defective Tag is out of read zone i-PORT does not scan on various antennas Antennas are not being triggered No messages on Port 7090 (Debug port) Debug Info has been turned off
(7090) No connection with i-PORT File download unsuccessful, i.e. i-PORT does not accept the file Internet browser cannot display i-PORT web page
- Do optical check to see if antenna is defective
- Hold the test tag in front of the antenna and check if antenna is being recognized (blinks, i.e. Debug port)
- Check if the antennas in question are activated and scan-enabled (see Configuration)
- Check if Debug port is activated (i.e. which data is being transmitted)
- Check the IP address and the network cable Change antenna(s) if necessary If necessary, adjust the output power to the requirements Turn on the desired antennas Activate the Debug port
(Configuration) Change the IP address if required or change the network cable Browser is trying to access Proxy Server
- Deactivate your Internet browsers proxy function Document ID: UG-i-PORT III NAE
-32-
i-PORT III Users Guide 9.0 Contact Information In North America:
Canada In Europe:
IDENTEC SOLUTIONS, Inc. Suite 102 1860 Dayton Street Kelowna, British Columbia Canada V1Y 7W6 Tel.: +1 250 860 6567 Fax: +1 250 860 6541 Austria IDENTEC SOLUTIONS AG Millenniumspark 2 A-6890 Lustenau / sterreich Tel.: +43 5577 87387-0 Fax: +43 5577 87387-15 www.identecsolutions.com Document ID: UG-i-PORT III NAE
-33-
i-PORT III Users Guide Appendix A Configuration Parameters i-PORT Configuration Descriptions Key i-PORT General IportType Value min max default unit type 0 1 0 Description IportMainID IportSubID IportSerlDevice 0 0 0 65535 65535 3 0 0 0 enum 0...Host 1...Client Main identification number of the i-PORT Sub identification number of the i-PORT uint uint enum Selects the device connected to serial interface 180. 90. 0. 0. deg deg float float 0...no device 1...GPS device 2...Modem 3...Serial Host ( Comm. Protocol serial ) Longitude co-ordinates (east) of the i-Port Latitude co-ordinates (north) of the i-Port 0.0.0.0 IP Defines the IP address of the host computer
-180.
-90. IportLongitude IPortLatitude Host Connection HostIpAddr HostPort HostTimeOut 0.0.0.0 255.255. 255.255 65535 32767 0 0 6780 2 uint sec uint HostSyncInterval 0 HostSendInterval 0 32767 32767 0 2 sec uint sec uint HostListSize 0 32767 0 uint Port number of the host computer Timeout for acknowledge from host > send it again Time interval to synchronise iPort clock with host clock 0...never Time interval to send messages (only if available) to host OR Send Interval of Events Minimum list size to send whole message list to host 0...send interval controlled only by HostSendInterval Debug Configuration DebugHostMirror 0 1 DebugTagList DebugNewTag DebugScanTag Time Server TimeServerType 0 0 0 0 32767 1 1 2 TimeServerPriIP 0.0.0.0 255.255. 255.255 TimeServerSecIP 0.0.0.0 255.255. 255.255 65535 TimeSyncInterval 1 1 0 0 1 0 0.0.0.0 0.0.0.0 1 bool sec uint bool bool 0...no debug output 1...mirrors the communication to host to debug port Debug output cycle time Sends all new entries of tags in the list to debug port Sends all tags from the last scan to debug port uint IP IP uint 0disable Time server 1SNTP 2Daytime Time interval to synchronise iPort clock with server Document ID: UG-i-PORT III NAE
-34-
Key Scan ScanMode ScanSlotSelect ScanNum ScanPause Value min max default unit type Description 0 0 0 0 2 16 32767 32767 1 5 1 10 enum 0...Host Only no cont. Sequence 1...Continuos Mode 2...Input1 Mode 2^x Number of Slots Number of sequences Input1 mode Pause after a sequence uint uint uint 0.1 sec 0 Blink BlinkEnable Read Data ReadEnable ReadAddress ReadNum ReadBoost ReadRetries Tag Power Saving 0 PowSaveEnable PowSaveMode 0 0 0 1 0 0 PowSaveDuration 0 Detection DetectTagType 0 DetectMode DetectDuration DetectInhibit Event Message EventMsgEnable EventRnTag EventRnInput1 0 0 0 0 0 0 0 0 0 0 0 EventRnInput2 EventRnInput3 EventRnInput4 EventCntIPortID EventCntDateTim e EventCntTagStat 0 EventCntFStr 0 1 0 bool 1...All new Tags in field BLINK once 1 32767 32 20 60 0 256 12 6 3 1 2 255 2 2 0 0 2 0 0 dB bool uint uint int uint 1...Enable read data from tags Start Address to read data Number of byte to read Power factor for read operation Number of retries bool enum 0...Sleep 1...All actual Tags in field Power save 1...Mute ( only for i-Dx) 2...Both How long the Tag should save power sec uint enum 0...i-Qx 1...i-Dx 2...Both Note: i-Dx does not work in this version!
enum 0...Normal Detection 32767 32767 5 10 sec uint sec uint 1...Maximum Level Detection 2...In/Out Time for Max Level to detect a maximum How long a tag have to be out of field to be cleared 1 2 3 3 3 3 1 1 1 1 0 0 0 0 0 0 0 0 0 0 1...enable Events bool enum 0...When a Tag enters the field 1...When a Tag leaves the field 2...Both enum 0...No Event 1...Rising Edge 2...Falling Edge 3...Change Send i-PORT ID Send Date and Timed (UTC) enum enum enum bool bool bool bool Send Status of Tag Send Field Strength Info i-PORT III Users Guide Key Antenna Settings Ant1Enable 0 1 Ant1ScanEnable Ant1TxPowerQ Ant1TxPowerD 0 1
-30 6
-30 30 Value min max default unit type Description bool Enable or disable this antenna 0...disable antenna 1...enable antenna 1 1
-6 20 dBm dBm Ant1RxThreshold Ant1HighSens
-100 -20 0 1
-100 0 dBm Ant1CableLoss Ant1SynchGroup
-20 20 0 4 Ant2Enable 0 1 Ant2ScanEnable Ant2TxPowerQ Ant2TxPowerD 0 1
-30 6
-30 30 0 0 0 1
-6 20 dB dBm dBm Ant2RxThreshold Ant2HighSens
-100 -20 0 1
-100 0 dBm Ant2CableLoss Ant2SynchGroup
-20 20 0 4 Ant3Enable 0 1 Ant3ScanEnable Ant3TxPowerQ Ant3TxPowerD 0 1
-30 6
-30 30 0 0 0 1
-6 20 dB dBm dBm Ant3RxThreshold Ant3HighSens
-100 -20 0 1
-100 0 dBm Ant3CableLoss Ant3SynchGroup
-20 20 0 4 Ant4Enable 0 1 Ant4ScanEnable Ant4TxPowerQ Ant4TxPowerD 0 1
-30 6
-30 30 0 0 0 1
-6 20 dB dBm dBm Ant4RxThreshold Ant4HighSens
-100 -20 0 1
-100 0 dBm Ant4CableLoss Ant4SynchGroup
-20 20 0 4 0 0 dB bool 1...antenna is a sending antenna int int TX Power for i-Qx TX Power for i-Dx Note: This command has no effect in this version!
Receive Threshold int bool 0...antenna low sensitive 1...antenna high sensitive Calibration factor to cal. antenna and cable int enu m bool Enable or disable this antenna 0...disable antenna 1...enable antenna bool 1...antenna is a sending antenna int int TX Power for i-Qx TX Power for i-Dx Note: This command has no effect in this version!
Receive Threshold int bool 0...antenna low sensitive 1...antenna high sensitive Calibration factor to cal. antenna and cable int enu m bool Enable or disable this antenna 0...disable antenna 1...enable antenna bool 1...antenna is a sending antenna int int TX Power for i-Qx TX Power for i-Dx Note: This command has no effect in this version!
Receive Threshold int bool 0...antenna low sensitive 1...antenna high sensitive Calibration factor to cal. antenna and cable int enu m bool Enable or disable this antenna 0...disable antenna 1...enable antenna bool 1...antenna is a sending antenna int int TX Power for i-Qx TX Power for i-Dx Note: This command has no effect in this version!
Receive Threshold int bool 0...antenna low sensitive 1...antenna high sensitive Calibration factor to cal. antenna and cable int enu Document ID: UG-i-PORT III NAE
-36-
i-PORT III Users Guide AntWEnable 0 1 AntWScanEnable AntWTxPowerQ AntWTxPowerD 0 1
-30 6
-30 30 AntWSynchgroup 0 4 0 0
-6 20 0 m bool Enable or disable this antenna 0...disable antenna 1...enable antenna dBm dBm bool 1...antenna is a sending antenna int int TX Power for i-Qx TX Power for i-Dx Note: This command has no effect in this version!
Document ID: UG-i-PORT III NAE
-37-
i-PORT III Users Guide Notes Document ID: UG-i-PORT III NAE
-38-
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2004-10-22 | 868.35 ~ 868.35 | DXX - Part 15 Low Power Communication Device Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2004-10-22
|
||||
1 | Applicant's complete, legal business name |
Identec Solutions AG
|
||||
1 | FCC Registration Number (FRN) |
0006172258
|
||||
1 | Physical Address |
Millennium Park 2
|
||||
1 |
6890 Lustenau, N/A
|
|||||
1 |
Austria
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
s******@phoenix-testlab.de
|
||||
1 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
OO4
|
||||
1 | Equipment Product Code |
IPORT3-NAE
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
K******** H******** F****
|
||||
1 | Title |
VP Hardware Development
|
||||
1 | Telephone Number |
43-55******** Extension:
|
||||
1 | Fax Number |
43-55********
|
||||
1 |
k******@identecsolutions.at
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
Senton GmbH
|
||||
1 | Name |
J****** R****
|
||||
1 | Physical Address |
Aeussere Fruehlingstrasse 45
|
||||
1 |
Straubing, D-94315
|
|||||
1 |
Germany
|
|||||
1 | Telephone Number |
+49 9********
|
||||
1 | Fax Number |
+49 9********
|
||||
1 |
j******@senton.de
|
|||||
app s | Non Technical Contact | |||||
1 | Firm Name |
Senton GmbH
|
||||
1 | Name |
J******** R******
|
||||
1 | Physical Address |
Aeussere Fruehlingstrasse 45
|
||||
1 |
Straubing, D-94315
|
|||||
1 |
Germany
|
|||||
1 | Telephone Number |
+49 9********
|
||||
1 | Fax Number |
+49 9********
|
||||
1 |
j******@senton.de
|
|||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DXX - Part 15 Low Power Communication Device Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Transceiver for ID-System | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
TUV SUD Product Service GmbH PS-EMC-STR
|
||||
1 | Name |
R******** H********
|
||||
1 | Telephone Number |
49-09********
|
||||
1 | Fax Number |
49-09********
|
||||
1 |
r******@tuev-sued.de
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 868.35000000 | 868.35000000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC