Move/2600 User Guide www.ingenico.com13-17 rue Pags, 92150 Suresnes FranceBanks and Acquirers International Holding SAS / 814 767 216 RCS Nanterre Contents 1. Introduction 2. Presentation 2.1 Content of the box 2.2 Overview on the Move/2600 2.3 Keyboard details and functionality 3. Use of the terminal 3.1 Switching off the terminal 3.2 Reading card 4. Installation 4.1 Recommendations 4.2 Terminal connections 4.2.1 USB 4.3 Opening trap door 4.4 SAMs & SIMs 4.5 Cable connection 4.6 Battery 4.6.1 Main characteristics 4.6.2 Installing the battery 4.6.3 Charging the battery 4.6.4 Changing the battery 2 4 5 5 6 8 9 9 9 11 11 11 11 12 13 14 15 15 15 16 17 Move 2600900050198 R11 000 02 / 0123Copyright 2023 Ingenico -Banks and AcquirersInternational Holding SASAll rights reserved 4.7 Paper roll 4.7.1 Main characteristics of Igenico roll 4.7.2 Installing paper roll 5. Troubleshooting 18 18 18 20 3 Move 2600900050198 R11 000 02 / 0123Copyright 2023 Ingenico -Banks and AcquirersInternational Holding SASAll rights reserved 1. Introduction We hope that you will be fully satisfied with your new terminal Move/2600. Please select by yourself in this documentation items related to your model. Read this guide to understand and make the best use of your terminal. It presents you the necessary information about use, installation, maintenance, safety and security recommendations. WARRANTY / SECURITY Use only the power supply included with the product to ensure best performance and safety. Maintenance should only be provided by Ingenico authorized technician. Failure to comply with these instructions will void the manufacturers responsibility. This symbol indicates an important Warning. This symbol indicates a piece of advice. 4 Move 2600900050198 R11 000 02 / 0123Copyright 2023 Ingenico -Banks and AcquirersInternational Holding SASAll rights reserved 2. Presentation 2.1 Content of the box Move/2600 terminal unit equipped with a paper roll A battery pack Power Supply Unit (PSU) ADVICE Keep the packaging. It must be re-used whenever the terminal is shipped. 5 Move 2600900050198 R11 000 02 / 0123Copyright 2023 Ingenico -Banks and AcquirersInternational Holding SASAll rights reserved 2.2 Overview of the Move/2600 24 LCD Display Contactless Card Reader Backlight keyboard with large key Easy Loading Printer Smart Card Reader Magnetic Stripe Reader 6 Move 2600900050198 R11 000 02 / 0123Copyright 2023 Ingenico -Banks and AcquirersInternational Holding SASAll rights reserved Compartment where are located:
The battery pack The SIM/SAM slots Weight (without paper roll nor battery) 254g Dimensions (L x w x h) 167x76x56 mm Electrical mains network 100 - 240VAC / 50-60 Hz or 50/60Hz -
Class II equipment Connections on terminal USB-C connector for PSU 7 Move 2600900050198 R11 000 02 / 0123Copyright 2023 Ingenico -Banks and AcquirersInternational Holding SASAll rights reserved 2.3 Keyboard details and functionality Some keys can have other functions according to the applications that are in the terminal. NAVIGATION keys CANCEL key CLEAR key VALIDATION key FEED PAPER 8 Move 2600900050198 R11 000 02 / 0123Copyright 2023 Ingenico -Banks and AcquirersInternational Holding SASAll rights reserved 3. Use of the terminal Before using the terminal, always check if the paper roll is present and if battery is connected. Without battery pack connected, printer and 4G connectivity wont be available. 3.1 Switching off the terminal If the battery is empty and the terminal in use is removed from its base, the terminal automatically shuts off. It may also be switch by pressing simultaneously and (yellow key) for one second. In order to restart the terminal, press on the keyboard. 3.2 Reading card Magnetic stripe card The card can be read either from left to right or from right to left, with the stripe on top of the terminal (stripe can be seen by user). Use a regular movement to ensure a reliable card reading. 9 Move 2600900050198 R11 000 02 / 0123Copyright 2023 Ingenico -Banks and AcquirersInternational Holding SASAll rights reserved Smart card insert the card horizontally with the chip facing upwards and leave in position throughout the transaction. Contactless (Cless) Bring the card firmly up to the active zone. Keep the card close to the reader during the transaction. The 4 virtual LEDs are displayed during the transaction. The terminal behavior for the cardholder may depend on:
The terminal environment Local usage (language,...) 10 Move 2600900050198 R11 000 02 / 0123Copyright 2023 Ingenico -Banks and AcquirersInternational Holding SASAll rights reserved 4. Installation 4.1 Recommendations Location of the Move/2600 Place the product on flat surface near an electric socket and according to the options close to an Ethernet socket. The terminal should be placed far from any very hot zones, protected from vibrations, dust, damp and electromagnetic radiation (computer screen, anti-theft barrier etc.). Operating conditions Ambient temperature from +0C to +50C Max relative humidity 85% at +40C Battery charging conditions Ambient temperature from +0C to +45C Storage conditions Ambient temperature from -20C to +55C Max relative humidity 85% at +55C 4.2 Product connections 4.2.1 Terminal USB A USB type C connector is available behind the battery door of Move/2600. This connector is used to connect PSU or USB type C to USB slave type A cable or USB type C to USB Host connector. This connector can also be used for SW loading. 11 Move 2600900050198 R11 000 02 / 0123Copyright 2023 Ingenico -Banks and AcquirersInternational Holding SASAll rights reserved 4.3 Opening trap door CAUTION Switch off the terminal before opening the trapdoor. Turn the terminal and unclip the trapdoor by pushing on the clip with as shown with the arrows on the picture 12 Move 2600900050198 R11 000 02 / 0123Copyright 2023 Ingenico -Banks and AcquirersInternational Holding SASAll rights reserved 4.4 SAMs & SIMs The connector modules security SAM/SIM is located inside the terminal, in a closed compartment. Please, switch off the Move/2600 prior inserting the SIM/SAM. SAMs and SIMs are identified by the engraved marks on the lower housing When introducing a SAM/SIM in its slot, be sure to put the cut corner as indicated on the engraved marks 3 factory options: 1SIM/2SAMs, 2SIMs/1SAM or 3 SAMs (always 3 SAMs when product doesnt embed 4G option) SIM 1 connector or SAM 2 connector SAM 1 Connector SIM 2 connector or SAM 3 connector 13 Move 2600900050198 R11 000 02 / 0123Copyright 2023 Ingenico -Banks and AcquirersInternational Holding SASAll rights reserved 4.5 Cable connection To use Magic Box connectivity, the use of cable is necessary and is included in your product box in option. Connect the cable and make it follow the cable way as shown on following picture. Take care to place it behind the plastic wall. Plug can be inserted in both directions. 14 Move 2600900050198 R11 000 02 / 0123Copyright 2023 Ingenico -Banks and AcquirersInternational Holding SASAll rights reserved 4.6 Battery 4.6.1 Mains characteristics Characteristics Li-Ion 2250mAh Charge (power supply 1A) 50% of capacity in 1.5h (1A) Full capacity in 4h (1A) Battery life 450 transactions in 4G with fully charged battery, printing and backlit activated Can remain powered ON up to 150 hours with connected 4G link and terminal in sleeping state starting with fully charged battery and without energy consumption related to backlit or radio link 4.6.2 Installing the battery WARNING Check that the terminal is not connected to the main electric network before installing or removing the battery. Turn your terminal and unclip the battery trapdoor by pushing on the button as shown on the picture Disengage the trapdoor Take the battery pack included in the box Locate the battery pack connector beside the battery compartment 15 Move 2600900050198 R11 000 02 / 0123Copyright 2023 Ingenico -Banks and AcquirersInternational Holding SASAll rights reserved Plug the battery pack connector according to the connector locating system and (as shown on picture). Verify that it locks. Place compartment. the battery pack in its Close the battery compartment trapdoor. 4.6.3 Charging the battery When does the battery need to be charged?
/ On initial start-up, charge the battery for 16 hours under the environmental conditions stated above
/ When used with a terminal power supply: connect the power supply to Move/2600 power connector How does the battery need to be charged?
/ The environment in which the charge takes place influences battery lifetime and autonomy (number of transactions) The optimal conditions are as follows:
/ Charging away from any external heat source
(radiator, sun, enclosed area)
/ The optimal temperature is between +15C and
+25C How can the battery be charged?
Using the terminal power supply
/ Connect the terminal power supply unit to the terminal USB type C connector located above the battery door
/ Connect the power supply unit to the power supply mains networks
/ Check to see if the battery symbol is flashing or moving
(=battery charging) 16 Move 2600900050198 R11 000 02 / 0123Copyright 2023 Ingenico -Banks and AcquirersInternational Holding SASAll rights reserved 4.6.4 Changing the battery It is imperative to use the battery authorized by Ingenico. There is danger of explosion if battery used is not approved by Ingenico. Disconnect the power supply unit Turn product off by pressing simultaneously (dot key) and
(yellow key) for one second. Remove the battery door (See chapter Installation). Lift the battery and remove it from its compartment. Carefully disconnect battery by pulling on connector. Avoid pulling wires to do not damage the battery. Connect and install the new battery by following the instructions in chapter Installation. In order to preserve the environment, dispose used battery in compliance with current country recycling legislation. 17 Move 2600900050198 R11 000 02 / 0123Copyright 2023 Ingenico -Banks and AcquirersInternational Holding SASAll rights reserved 4.7 Paper roll 4.7.1 Main characteristics of Ingenico roll Paper roll characteristics Precisions Color Width Diameter Length White 58 mm 40 mm About 18 meters The thermal paper can be deteriorated by poor storage conditions, so we recommend you to avoid:
Storage in hot wet places (near air-conditioner, humidity higher than 85%) Exposure to sunlight or ultraviolet for long periods Contact with organic solvents (solvent type adhesive Direct contact with materials containing plasticizers (PVC transparent folders or envelopes) Direct contact with diazo papers Direct contact with water Rubbing or pressing the paper too strongly WARNING For best product performance, only use heat sensitized paper approved by Ingenico. 4.7.2 Installing paper roll WARNING Switch off the terminal prior to installing a paper roll. Use only paper approved by Ingenico. The use of non-
approved paper is likely to damage the printer of your terminal. 18 Move 2600900050198 R11 000 02 / 0123Copyright 2023 Ingenico -Banks and AcquirersInternational Holding SASAll rights reserved Open the paper compartment by lifting the catch located at the rear and under the terminal and pull the cover. Insert the paper roll in the compartment following the directions shown on the below picture. Pull the paper up to the top of the terminal. Maintain the paper and close the lid. Press simultaneously on both upper corners of the paper flap until it clips into position. ADVICE If you insert a new paper roll, tear off the first length
(one complete turn to avoid printing on adhesive tape footprint). 19 Move 2600900050198 R11 000 02 / 0123Copyright 2023 Ingenico -Banks and AcquirersInternational Holding SASAll rights reserved 5. Troubleshooting The terminal does not turn on Check the battery (is it discharged, is it connected?). A full discharged battery can take long charging time to recover. Connect terminal to terminal power supply or put it on powered base. Cards are not read Check that the magnetic card is swiped correctly (with magnetic band on terminal side). Swipe again the card with the magnetic stripe movement constant and rapid Verify that the magnetic strip is not damaged, grooved or cracked Make sure you have inserted correctly the smart card into the smart card reader and removed the card only after the transaction is performed. The ticket is not printed Check the presence and proper positioning of the paper roll. Possibly adjust the paper roll following the instructions in this manual (section 0 Installing the paper roll) Check the type of paper used (thermal paper must be used) Verify thermal paper sensitive side. Check battery pack is correctly connected. 20 Move 2600900050198 R11 000 02 / 0123Copyright 2023 Ingenico -Banks and AcquirersInternational Holding SASAll rights reserved 6. FCC/ISED Compliance You are cautioned that changes or modifications not expressly approved by the part responsible for compliance could void the users authority to operate the equipment. interference This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in instruction, may cause harmful accordance with interference communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on, the user is encouraged to try to correct interference by one or more of the following measures :
the to radio Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules and Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) and (2) including interference that may cause undesired operation. This device may not cause harmful interference, This device must accept any interference received, Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes :
(1) lappareil ne doit pas produire de brouillage, et lutilisateur de lappareil doit accepter tout brouillage
(2) radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. Move 2600 900050198 R11 000 02 / 0123 21 Copyright 2023 Ingenico -Banks and AcquirersInternational Holding SASAll rights reserved to reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Conformment la rglementation dIndustrie Canada, le prsent metteur radio peut fonctionner avec une antenne dun type et dun gain maximal (ou infrieur) approuv pour lmetteur par Industrie Canada. Dans le but de rduire les risques de brouillage radiolectrique lintention des autres utilisateurs, il faut choisir le type dantenne et son gain de isotrope rayonne quivalente sorte que
(p.i.r.e.) ltablissement dune communication satisfaisante. No changes shall be made to the equipment without the permission of Ingenico as this may void the users authority to operate the equipment. Tout changement apport ce terminal non expressment approuv par Ingenico est susceptible dannuler le droit de lutilisateur se servir de cet quipement. ne dpasse pas la puissance ncessaire lintensit The device for operation in the band 51505250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile satellite systems. In addition, high-
power radars are allocated as primary users (i.e. priority users) of the bands 52505350 MHz and 56505850 MHz and that these radars could cause interference and/or damage to LE-LAN devices. Les dispositifs fonctionnant dans la bande de 5 150 5 250 MHz sont rservs uniquement pour une utilisation risques de brouillage lintrieur afin de prjudiciable aux systmes de satellites mobiles utilisant les mmes canaux. Dautre part, les utilisateurs de radars de haute puissance sont dsigns utilisateurs principaux (c.--d., quils ont la priorit) des bandes de 5250 5350 MHz et de 5650 5850 MHz et, dautre part, que ces radars pourraient causer du brouillage et/ou des dommages aux dispositifs de RL-EL. rduire les Move 2600 900050198 R11 000 02 / 0123 22 Copyright 2023 Ingenico -Banks and AcquirersInternational Holding SASAll rights reserved Your contact www.ingenico.com 13-17 rue Pags, 92150 Suresnes France Banks and Acquirers International Holding SAS / 814 767 216 RCS Nanterre Move 2600 900050198 R11 000 02 / 0123 23 Copyright 2023 Ingenico -Banks and AcquirersInternational Holding SASAll rights reserved