MODU/7002 Xtra module Technical Guide Contents 1_ Introduction ............................................................................................ 3 2_ Xtra module general information ........................................................... 4 2_1 Physical dimensions ....................................................................................... 4 2_2 Xtra module Features ..................................................................................... 5 3_ Xtra module Technical information ....................................................... 6 3_1_1 Hardware architecture: ................................................................................................... 7 3_1_2 Wireless Connectivity ..................................................................................................... 8 3_1_3 Internal Frequencies ..................................................................................................... 10 4_ Norms&Marking .................................................................................... 11 4_1 1 Federal Communications Commission (FCC) Statement & Industry Canada (IC) Statement ............................................................................................................ 11 1_Introduction This technical guide is a document that describes the features of the terminal. 2_Xtra module general information 2_1 Physical dimensions 21 mm Mechanical characteristics External dimensions Weight Casing material 55 mm 45 mm 55 (L) x 45 (W) x 21 (H) mm 15g (full options) ABS-PC + TPU 15 g 2_2 Xtra module Features Wireless connectivity o Wifi o Bluetooth 3_Xtra module Technical information Name Operating temperature 0C to +40C (32F to 104F) Environment Storage temperature
-20C to +55C (-4F to 131F) Operating humidity 85% non-condensing at +40C (104F) Xtra module 3_1_1 Hardware architecture:
3_1_2 Wireless Connectivity
/ Wi-Fi WiFi connection is optional in Lane/7000 or Lane/8000. This feature is useful to wirelessly connect your terminal to the IP network avoiding the cabling task:
Feature Chipset Standard compliance Frequency band Dualband :2.4 GHz and 5 GHz Wi-Fi Marvell 88W8782 802.11 a/b/g/n, SISO, 2.4Ghz and 5Ghz, HT20&HT40 20Mhz Channel : 2412-2472 Ghz / 5180-5320 Ghz / 5500-5700 Ghz / 5700 Ghz / 5745-5805 Ghz 40Mhz Channel : 2442-2452 Ghz / 5190-5310 Ghz / 5510-5670 Ghz / 5755-5795 Ghz www.ingenico.com 28/32, boulevard de Grenelle, 75015 Paris - France / (T) +33 (0)1 58 01 80 00 / (F) +33 (0)1 58 01 91 35 Ingenico S.A. au capital de 53 086 309 / 317 218 758 RCS PARIS Radio transfer rate Distance Max output power Home security Enterprise security
/ Bluetooth Feature Chipset Standard compliance Profile Radio transfer rate Number of supported links on SPP Range Maximum output power From 1 Mbit/s to 135 Mbit/s Indoor: 70m typical, mini 100m in free sight 2.4Ghz : 23dBm 5Ghz : 13 dBm WPA, WPA2 EAP-MD5, EAP-TLS, EAP-TTLS, EAP-PEAPv0, EAP-SIM Bluetooth V2.0 BC08, CSR8811:
http://www.csr.com/sites/default/files/csr8811.pdf Bluetooth 4.0 (Frequency : 2.4Ghz) Bluetooth 4.2 planned on roadmap (Frequency: 2.4Gz) SPP A2DP Other profile to be analyzed on request 1 Mbit/s 3Mbit/s (EDR) 1 open link to PCL 4 reserved for peripherals (barcode, printer, ) Bluetooth Class 2 max 10m in free sight GFSK : 1.5 dBm Pi/4 DQPSK : 1.8 dBm 8 DPSK : 2.1 dBm 9/12 MODU/7002 Copyright 2014 Ingenico / All rights reserved 3_1_3 Internal Frequencies Bluetooth :
o Quartz = 26Mhz Wifi :
o Quartz = 40Mhz 10/12 MODU/7002 Copyright 2014 Ingenico / All rights reserved 4_Norms&Marking 4_1 1 Federal Communications Commission (FCC) Statement &
Industry Canada (IC) Statement Modular transmitter 15.212 Changes or modifications made to the equipment not expressly approved by INGENICO may void the FCC / IC authorization to operate this equipment. The use of the transceiver module is authorized in mobile or fixed host devices taking into account the conditions listed below:
OEM Integrator must ensure that the end user manual may not contain any information about the way to install or remove the module from the final product. Depending on the final host device additional authorization requirements for the non-
transmitter functions of the transmitter module may be required (i.e., Verification, or Declaration of Conformity) The OEM integrator is responsible for ensuring that after the module is installed and operational the host continues to be compliant with the Part 15B unintentional radiator requirements. The information on the label and in the user manual is required to be incorporated in the user manual of the final host. see 47 CFR15 requirements for more details (e.g. 15.19 / 15.21 /
15.101 / 15.105 / RSS-GEN / ICES) Additional label with the words Contains FCC ID: XKB-M7002WIBT and Contains IC: 2586D-
M7002WIBT shall be applied and visible from the outside of the host product. The module must be installed and used in strict accordance with the manufacturers instructions as described in the user documentation that comes with the module. The end user manual for the final host product operating with this transmitter must include operating instructions to satisfy RF exposure compliance requirements. Radiofrequency radiation exposure Information :
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance of 20 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Cet quipement est conforme aux limites d'exposition aux rayonnements IC tablies pour un environnement non contrl. Cet quipement doit tre install et utilis avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps. The antenna of the module may not be removed, replaced nor modified. The antenna must not be co-located or operating in conjunction with any other antenna or transmitter. No additional antenna must be used. 11/12 MODU/7002 Copyright 2014 Ingenico / All rights reserved When the final host product operating with this transmitter deviate from above, installation of this module into specific final hosts may require the submission of a Class II permissive change application containing data pertinent to RF Exposure, spurious emissions, ERP/EIRP, and host/module authentication, or new application if appropriate. Feel free to contact us if additional guidance is required. 12/12 MODU/7002 Copyright 2014 Ingenico / All rights reserved