ON TOO N T Adjustable Wrench Tape Measure Scissors or Snip IMPORTNT SFEGURDS
I $ &) ( &!
E II
EFE I I
IE
E,! $
" , #""( ( A $(& (#
&#)".F) (
&)(."(&&)$(& F
!!( , SVE THESE INSTRUCTIONS
$&(#" # ( %)$!"( )(#&- )"& +*& ) , ( F " )( (# ( # #+" #"(#" * !, "#(
"#&!(#" B)&) # ( F 859842AB 2 Kohler Co., Kohler, WI BEFORE YOU BEGIN WARNING: Do not use intank cleaners. Products containing chlorine (calcium hypochlorite) can seriously damage this product as well as the other fittings in your toilet. Kohler Company shall not be responsible or liable for any damage caused by the use of cleaners containing chlorine.
Do not attempt to repair or replace the AC adapter.
Do not use an extension cord with this product.
Electrical service requirements: 120 VAC, 60 Hz
(circuit protected by a Class A GFCI). The kit uses a 6'
lowvoltage electrical cord and AC adapter.
This ventilating toilet kit uses a motionsensing device to automatically turn itself on and off.
Plug in the AC adapter only after the ventilating toilet kit is properly installed in the toilet tank. INSTALL ELECTRICAL SERVICE (IF NEEDED) 1. NOTE: You can use an existing electrical service if it meets the following requirements. A licensed electrician should install a properlygrounded, groundingtype receptacle which is protected by a GFCI. We recommend that the electrician locate the receptacle no less than 6" above the floor line, and within a 32" radius measured level with the toilet ledge, as shown. NOTE: Do not connect this product to an extension cord. 32" R. 6" MIN. Kohler Co., Kohler, WI 3 859842AB 2. INST THE KIT Remove the tank cover If your toilet uses a fill valve with a float ball you must replace it with a compact fill valve such as a Fluidmaster 400A Replace the fill valve according to the manufacturer's instructions We recommend a flapper without a bottom cone to optimize performance of the ventilating toilet kit
F$ T# F ! "
! Flapper with Bottom Cone Flapper without Bottom Cone Adjust the tank water line so it is at least 7/8" from the top of the overflow to ensure correct operation of the ventilating kit
L L
F
859842AB 4 Kohler Co., Kohler, WI Shut off the water supply to the toilet, and flush the toilet to relieve the water pressure. Remove and discard the existing refill tube from the fill valve. Position the snorkel assembly over the overflow tube, and hang the snorkel assembly on the back wall of the tank. Adjust the snorkel assembly from sidetoside and fronttoback to prevent interference with the trip lever linkage, fill valve, and tank walls. Connect the new refill tube to the overflow tube. Make sure the refill tube points directly down into the overflow tube to ensure proper toilet operation. Trim away any excess tube length. Then connect the new refill tube to the fill valve. Turn on the water supply to the toilet. Allow the toilet tank to fill until it shuts off. Recheck the water level to ensure a 7/8"
minimum space between the water line and the top of the overflow. Snorkel Assembly Existing Refill Tube Overflow Tube Refill Tube Kohler Co., Kohler, WI 5 859842AB Install the fan and filter assembly to the snorkel assembly by first engaging the two clips located on the left side of each assembly. Then squeeze the right side of both assemblies together to snap in place. Fan and Filter Assembly Clips Snorkel Assembly Clips Route the power cord between the hooks, and plug the AC adapter into a properlygrounded, groundingtype receptacle which is protected by a GFCI. Reinstall the tank cover. Power Cord Hook Hook 859842AB 6 Kohler Co., Kohler, WI 3. OPERATION This kit is equipped with a builtin motion sensor for automatic activation and deactivation from inside the toilet tank.
The ventilating toilet kit will run for up to 60 seconds when initially plugged in.
The kit turns on when it senses motion above the toilet bowl area, or when the toilet is flushed.
The kit remains on as long as it senses motion every 90 seconds.
The kit turns off automatically about 90 seconds after the user leaves the toilet, or after the toilet flush sequence ends. Kohler Co., Kohler, WI 7 859842AB 4. TROUBLESHOOTING SYMPTOM CAUSE REMEDY Noise after the flush. A gurgling noise may occur after the flush due to air and water interaction. Bowl water level is low. Refill tube not pointing down overflow tube. Water in filter. Kit activates by itself. Less than 7/8" from water line to top of overflow. Refill tube not pointing down overflow tube. Leaking flapper causing tank refill cycle. Normal operation. Reposition the refill tube. Adjust water line to at least 7/8" from top of overflow. Reposition the refill tube. Replace the flapper. Kit does not turn on. Unit not plugged in or power turned off. Plug in or turn on power. Kit does not turn off. A metal object is on the tank lid. Remove metal object from the tank lid. CALL US FOR HELP Questions? Problems? First review the installation instructions to ensure correct installation. For additional assistance in the USA, call our Customer Service Department for direct help. You may also contact us at our web site listed below. 18004KOHLER www.kohlerco.com 859842AB Kohler Co., Kohler, WI E2001 Kohler Co. 8 Kohler Co., Kohler, WI 859842AB