all | frequencies |
|
|
exhibits | applications |
---|---|---|---|---|---|
manuals |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 2 |
|
Manual 1 | Users Manual | 87.76 KiB | ||||
1 2 |
|
Manual 2 | Users Manual | 1.11 MiB | ||||
1 2 | Test Setup Photos | |||||||
1 2 | External Photos | |||||||
1 2 | ID Label/Location Info | |||||||
1 2 | ID Label/Location Info | |||||||
1 2 | Internal Photos | |||||||
1 2 | Cover Letter(s) | |||||||
1 2 | Test Report | |||||||
1 2 | Cover Letter(s) | February 11 2010 | ||||||
1 2 | Cover Letter(s) | February 11 2010 |
1 2 | Manual 1 | Users Manual | 87.76 KiB |
JOBNAME: No Job Name PAGE: 1 SESS: 3 OUTPUT: Tue Apr 27 20:27:06 2010 Homeowners Guide Toilets K-3900 M product numbers are for Mexico (i.e. K-12345M) Los nmeros de productos seguidos de M corresponden a Mxico
(Ej. K-12345M) Franais, page Franais-1 Espaol, pgina Espaol-1 1132336-5-A JOBNAME: No Job Name PAGE: 2 SESS: 3 OUTPUT: Tue Apr 27 20:27:06 2010 Important Information When using electrical products, especially when children are present, basic safety precautions should always be followed, including the following:
READ ALL INSTRUCTIONS BEFORE USING DANGER: To reduce the risk of electrocution:
DANGER: Risk of electric shock. Disconnect power before servicing. Do not reach for a product that has fallen into water. Unplug immediately. Do not use while bathing. WARNING: To reduce the risk of low-grade burns, electric shock, re, or injury to persons:
Close supervision is necessary when this appliance is used by or near the very young, the elderly, or invalids. Children should not be permitted to use or touch this appliance. Do not leave children unattended in any room where this product is installed. Adjust the temperature of the toilet seat for the elderly, those who are incapacitated, or persons with sensitive skin. Use this appliance only for its intended purpose as described in the manual. Do not use attachments Never operate this appliance if it has a damaged cord or plug, if it is not working properly, if it has not recommended by Kohler Co. been dropped, damaged, or dropped into water. Return the product to a service center for examination and repair. Keep the cord away from heated surfaces. Never block the air openings of the product. Keep the air openings free of lint, hair, and the like. Never use while sleeping or drowsy. Never drop or insert any objects into any opening or hose. Connect this product to a properly grounded outlet only. See Grounding Instructions. Install this product properly by following the installation procedure. Only authorized persons can install or repair the unit. Do not attempt to service this appliance yourself, doing so could void the warranty. WARNING: Risk of electric shock, re, or personal injury. This product must be grounded. Connect only to a dedicated 120 V AC, 60 Hz circuit protected by a minimum 15 A Ground-Fault Circuit-Interrupter (GFCI) or Residual Current Device (RCD). WARNING: Risk of electric shock or product damage. Do not immerse or ush the product with water. CAUTION: Risk of property damage: Do not push or pull on the water connection to prevent water leakage. CAUTION: Risk of property damage: In areas where water may freeze in the pipes, make arrangements to keep the pipes warm. Any water remaining in the seat may freeze during storage during the winter. Allow the unit to warm to room temperature before reinstalling or using. NOTICE: Risk of product damage:
Do not install this product in a location exposed to excessive moisture where condensation might form on the product surface. Provide adequate ventilation when bathing to avoid damage to the electronic components due to high humidity levels. Do not apply excessive force to the spray wands. Product may break. Do not install this seat in a location where water might be splashed on the product. Do not supply electrical power to the unit until the plumbing installation work has been completed. Allow the unit to cool to room temperature before installation or operation. The thermal protectors It could cause the product to malfunction. may trip during storage or transportation in warm weather causing the unit to not operate. User Instructions Before installation or for long-term storage of this product, protect the product by storing it in its original carton. Failure to do so may result product damage (such as scratches, loss of function) and/or dangerous situations (such as damage to the cord). 1132336-5-A 2 Kohler Co. JOBNAME: No Job Name PAGE: 3 SESS: 3 OUTPUT: Tue Apr 27 20:27:06 2010 Important Information (cont.) Verify the power cord and water hose are not susceptible to damage. Ensure the clips (provided) are attached evenly along the water hose and power cord. If the clips were not installed, attach them at this time. This will prevent twisting or damage to the water hose and power cord and will extend the life of the product. NOTE: This product is designed for installation with the electrical and water supplies located through either the wall or the oor. Grounding Instructions This product should be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This product is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded. DANGER: Risk of electric shock. Improper use of the grounding plug can result in a risk of electric shock. If repair or replacement of the cord or plug is necessary, do not connect the grounding wire to either at blade terminal. The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire. Check with a qualied electrician or service personnel if the grounding instructions are not completely understood, or if in doubt as to whether the product is properly grounded. Thank You For Choosing Kohler Company Thank you for choosing Kohler Co. Your Kohler Co. product reects the true passion for design, craftsmanship, artistry, and innovation Kohler Co. stands for. We are condent its dependability and beauty will surpass your highest expectations, satisfying you for years to come. All information in this guide is based upon the latest product information available at the time of publication. At Kohler Co. we strive to fulll our mission of improving the level of gracious living for each person who is touched by our products and services. We reserve the right to make changes in product characteristics, packaging, or availability at any time without notice. Please take a few minutes to review this guide. Pay special attention to the care and cleaning instructions. Manual Operation The basic functions of the toilet can be controlled manually using the buttons located on the right side of toilet. The lid and ring can be lifted manually to open and close them. Push the ush button will ush the toilet manually. Push the front wash button to active the bidet wand for front wash. Push the back wash button to active the bidet wand for front wash. Push the dryer button to activate the dryer. Care and Cleaning Kohler Co. shall not be responsible or liable for any tank tting damage caused by the use of cleaners containing chlorine (calcium hypochlorite). NOTE: When manually cleaning the bowl or wand, the remote must be used to extend the wand or open the bowl valve. Cleaning Functions To activate the cleaning functions:
On the home screen menu of the remote, select settings. In the settings menu, select cleaning. Kohler Co. 3 1132336-5-A JOBNAME: No Job Name PAGE: 4 SESS: 3 OUTPUT: Tue Apr 27 20:27:06 2010 Care and Cleaning (cont.) the hour and minutes settings. Automatic Wand Cleaning In the settings menu, select auto clean wand. To clean the wand, select run clean cycle. To schedule the wand to be cleaned at regular intervals automatically, select set schedule. To set the time the wand cleaning process will be performed, use the up/down arrows the change Select am or pm. Select next. Select the days the wand will be cleaned. More than one day may be selected. Select save. Apply schedule will appear with a check mark when the settings have been successfully created. Select home to return to the home page. Manual Cleaning NOTE: The open and close features are disabled while the manual cleaning menu is being used. In the settings menu, select manual clean. On the home screen menu of the remote, select settings. To clean the bowl, in the manual clean menu, select open bowl valve, and then clean the bowl. In the manual clean menu, select extend wand and clean the wand and surrounding area. Select home to return to the home page. dry any overspray that lands on nearby surfaces. General Cleaning Directions Always test your cleaning solution on an inconspicuous area before applying to the entire surface. Wipe surfaces clean and rinse completely with water immediately after applying cleaner. Rinse and Do not allow cleaners to soak on surfaces. Use a soft, dampened sponge or cloth. Never use an abrasive material such as a brush or scouring For Artist Edition Toilets: Treat your decorative product just as you would treat your ne china. pad to clean surfaces. DO NOT use bristle brushes or abrasive-backed sponges. They will scratch decorative surfaces. Use only warm water to clean. Dry with a cotton cloth or soft sponge. For detailed cleaning information and products to consider, visit www.kohler.com/clean. To order Care &
Cleaning information, call 1-800-456-4537. Remote Control Compliance FCC ID: N82-KOHLER001 Compliance Statement (Part 15.19) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. Warning (Part 15.21) Changes or modications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. FCC Interference Statement (Part 15.105 (b)) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful 1132336-5-A 4 Kohler Co. JOBNAME: No Job Name PAGE: 5 SESS: 3 OUTPUT: Tue Apr 27 20:27:06 2010 Remote Control Compliance (cont.) interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is Consult the dealer or an experienced radio/TV technician for help. RF Exposure Warning connected. This portable transmitter with its antenna complies with FCCs RF exposure limits for general population/uncontrolled exposure. This device must not be co-located or operating in conjunction with any other antenna or transmitter. CANADA IC: 4554A-KOHLER001 Industry Canada Statement per Section 4.0 of RSP-100 The term IC: before the certication/registration number only signies that the Industry Canada technical specications were met. Section 7.1.5 of RSS-GEN Operation is subject to the following two conditions:
1. This device may not cause interference, and 2. This device must accept any interference, including interference that may cause undesired operation of the device. Section 2.6 of RSS-102 This portable transmitter with its antenna complies with Industry Canada RF Exposure Limits for General Population/Uncontrolled Exposure. Modications: any modications mad to this device that are not approved by Kohler Co. may void the authority granted to the user by the FCC to operate this equipment. This Class B digital apparatus complies with Canadian ICES-003. Troubleshooting Information NOTE: When the remote is not in use, it will fall into standby mode after 3 minutes (6 minutes if the front or rear wash has ever been activated). Press the wake-up key at the top of the remote control screen to activate the remote. NOTE: If the back light in the window is off, the rst touch on the remote screen activates the light. The second touch activates the function. Start-up When the toilet is rst installed or the power fails, when power is restored or turned on the toilet will automatically go into start-up mode. If the toilet does not function correctly upon completing the start-up sequence, or it fails to start, contact customer service using the numbers located on the back page of this manual. Kohler Co. 5 1132336-5-A JOBNAME: No Job Name PAGE: 6 SESS: 3 OUTPUT: Tue Apr 27 20:27:06 2010 Troubleshooting Information (cont.) If the start-up sequence is successful, but troubleshooting is still needed, use the remote control to begin a diagnostic sequence. Running the Diagnostic Sequence On the home screen menu of the remote, select settings. In the settings menu, select maintenance. In the maintenance menu, select diagnostics. Select yes to run the diagnostics tool. If the issues cannot be resolved, contact Kohler customer service using the phone numbers listed on the back of this manual. Warranty KOHLER Faucet Lifetime Limited Warranty Kohler Co. warrants its Faucets* manufactured after January 1, 1997, to be leak and drip free during normal residential use for as long as the original consumer purchaser owns his or her home. If the Faucet should leak or drip during normal use, Kohler Co. will, free of charge, mail to the purchaser the cartridge necessary to put the Faucet in good working condition. This warranty applies only to Kohler Faucets installed in the United States of America, Canada or Mexico (North America). Kohler Co. also warrants all other aspects of the faucet or accessories (Faucet)*, (except gold, non-Vibrant, non-chrome nishes) to be free of defects in material and workmanship during normal residential use for as long as the original consumer purchaser owns his or her home. This warranty applies only to Kohler Faucets installed in North America. If a defect is found in normal residential use, Kohler Co. will, at its election, repair, provide a replacement part or product, or make appropriate adjustment. Damage to a product caused by accident, misuse, or abuse is not covered by this warranty. Improper care and cleaning will void the warranty**. Proof of purchase (original sales receipt) must be provided to Kohler Co. with all warranty claims. Kohler Co. is not responsible for labor charges, installation, or other incidental or consequential costs. In no event shall the liability of Kohler Co. exceed the purchase price of the Faucet. If the Faucet is used commercially or is installed outside of North America, or if the nish is gold, non-Vibrant or a painted or powder coated color nish, Kohler Co. warrants the Faucet to be free from defects in material and workmanship for one (1) year from the date the product is installed, under Kohler Co.s standard one-year limited warranty. If you believe that you have a warranty claim, contact Kohler Co., either through your Dealer, Plumbing Contractor, Home Center or E-tailer, or by writing Kohler Co., Attn.: Customer Care Center, 444 Highland Drive, Kohler, WI 53044, USA. Please be sure to provide all pertinent information regarding your claim, including a complete description of the problem, the product, model number, color, nish, the date the product was purchased and from whom the product was purchased. Also include your original invoice. For other information, or to obtain the name and address of the service and repair facility nearest you, call 1-800-4-KOHLER (1-800-456-4537) from within the USA and Canada, and 001-800-456-4537 from within Mexico, or visit www.kohler.com within the USA, www.ca.kohler.com from within Canada, or www.mx.kohler.com in Mexico. KOHLER CO. AND/OR SELLER ARE PROVIDING THESE WARRANTIES IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. KOHLER CO. AND/OR SELLER DISCLAIM ALL LIABILITY FOR SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states/provinces do not allow limitations of how long an implied warranty lasts or the exclusion or limitation of such damages, so these limitations and exclusions may not apply to you. This warranty gives the consumer specic legal rights. You may also have other rights that vary from state/province to state/province. This is Kohler Co.s exclusive written warranty.
*Trend faucets, MasterShowerTM tower, BodySpaTM systems and components; WaterHavenTM tower, systems 1132336-5-A 6 Kohler Co. JOBNAME: No Job Name PAGE: 7 SESS: 3 OUTPUT: Tue Apr 27 20:27:06 2010 Warranty (cont.) and components; TripointTM faucets, Polished Gold, non-Vibrant and painted or powder coated nishes, ttings; all items within the Fixture Related section of the Kohler Faucets Price Book, drains, Duostrainer sink strainers, soap/lotion dispensers; and faucets used in commercial settings, and outside North America, are covered by Kohler Co.s one-year limited warranty.
**Never use cleaners containing abrasive cleansers, ammonia, bleach, acids, waxes, alcohol, solvents or other products not recommended for chrome. This will void the warranty. Kohler Co. 7 1132336-5-A JOBNAME: No Job Name PAGE: 1 SESS: 1 OUTPUT: Tue Apr 27 20:27:06 2010 USA/Canada: 1-800-4KOHLER Mxico: 001-800-456-4537 kohler.com 2010 Kohler Co. 1132336-5-A
1 2 | Manual 2 | Users Manual | 1.11 MiB |
JOBNAME: No Job Name PAGE: 1 SESS: 17 OUTPUT: Wed Jun 23 13:46:00 2010 Installation Guide Toilet K-3900 M product numbers are for Mexico (i.e. K-12345M) Los nmeros de productos seguidos de M corresponden a Mxico
(Ej. K-12345M) Franais, page Franais-1 Espaol, pgina Espaol-1 1132336-2-A JOBNAME: No Job Name PAGE: 2 SESS: 17 OUTPUT: Wed Jun 23 13:46:00 2010 Important Information NOTE: This product is designed for installation with the electrical and water supplies located through either the wall or the oor. Grounding Instructions This product should be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This product is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded. DANGER: Risk of electric shock. Improper use of the grounding plug can result in a risk of electric shock. If repair or replacement of the cord or plug is necessary, do not connect the grounding wire to either at blade terminal. The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire. Check with a qualied electrician or service personnel if the grounding instructions are not This product is factory equipped with a specic electric cord and plug to permit connection to a completely understood, or if in doubt as to whether the product is properly grounded. proper electric circuit. Make sure that the product is connected to an outlet having the same conguration as the plug. No adapter should be used with this product. Do not modify the plug provided if it will not t the outlet, have the proper outlet installed by a qualied electrician. If the product must be reconnected for use on a different type of electric circuit, the reconnection should be made by qualied service personnel. Tools and Materials Drill with assorted Bits Screwdrivers Adjustable Wrench Wax Ring Before You Begin Plus:
Rug or Protective Material
Tape DANGER: Risk of electric shock. Disconnect power before servicing. DANGER: Risk of electric shock. For plug-in installations/wall-mounted electrical supply:
Connect only to a properly-grounded, grounding-type receptacle which is protected by a 120 V, 15 A, 60 Hz Ground-Fault Circuit-Interrupter (GFCI) or Residual Current Device (RCD). Do not remove the grounding pin or use a grounding adapter. CAUTION: Risk of personal injury. This toilet weighs approximately 100 lbs (45 kg). Lift the toilet with two people, employing proper lifting technique. 1132336-2-A 2 Kohler Co. JOBNAME: No Job Name PAGE: 3 SESS: 17 OUTPUT: Wed Jun 23 13:46:00 2010 Before You Begin (cont.) CAUTION: Risk of hazardous gases. If a new toilet is not installed immediately, temporarily place a rag in the oor ange opening. NOTICE: Follow all local plumbing and electrical codes. IMPORTANT! For ease of installation, install the docking station power cord before the sub wall and nished wall are installed. Observe all local plumbing and building codes. Carefully inspect the new toilet for damage. Consult the online users guide at kohler.com for more information. Kohler Co. reserves the right to make revisions in the design of products without notice, as specied in the Price Book. Kohler Co. 3 1132336-2-A JOBNAME: No Job Name PAGE: 4 SESS: 17 OUTPUT: Wed Jun 23 13:46:00 2010 29-1/2" (74.9 cm) 3-3/4" (9.5 cm) 14-1/2"
(36.8 cm) 25-3/4" (65.4 cm) 38" (96.5 cm) - 66" (167.6 cm) Front of Bowl 10-13/16" (27.5 cm) 4-3/4" (12.1 cm) 2-5/8"
(6.7 cm) D. 25-1/4"
(64.1 cm) 13-5/8"
(34.6 cm) 12"
(30.5 cm) Finished Wall 1-3/4"
(4.4 cm) 36-1/4"
(92.1 cm) 5-15/16"
(15.1 cm) Remote Dock 4-1/16"
(10.4 cm) 41" (104.1 cm) -
66" (167.6 cm) 2-1/4"
(5.7 cm) 15-5/8"
(39.7 cm) 1/2" NPS Supply 6"
(15.2 cm) Power Cord Reaches 56" (142.2 cm) 17-7/8"
(45.4 cm) Outlet 12" (30.5 cm) CL Of Outlet 8" (20.3 cm) 2" (5.1 cm) Rough-in - Wall Mount Electrical and Water Supply DANGER: Risk of electric shock. Disconnect power before servicing. NOTICE: The locations for the supply shut-off, electrical outlet, and docking station cord are suggested locations. Make sure all installations adhere to applicable codes and standards. IMPORTANT! If the supply shut-off is installed directly behind the toilet, the back panel cannot be removed for servicing. Removing the back panel would then require the entire toilet be removed. IMPORTANT! Do not install any items behind the toilet that will interfere with the seat when it is raised. All decorative items should be at least 37 high to allow clearance for the seat. The remote docking station is equipped with a 15 (4.5 M) power cord. The station mounting location shown for the docking station is ADA compliant. The supplied power cord is 56 (142.2 cm) in length. The cord should be installed before the nished wall are installed if possible. The toilet is equipped with a motion sensor to automatically open the seat when movement is sensed. This sensor has a maximum range of 51-1/2 (130 cm). Sensitivity can be adjusted using the User Interface. The toilet is equipped with a motion sensor seat actuator, located on the right side of the toilet. This sensor has a maximum range of 8 (20.3 cm). Keep this area free of obstructions. Supply stop inlet should be 1/2 NPT. Supply stop outlet needs to be 1/2 NPSM. 1132336-2-A 4 Kohler Co. JOBNAME: No Job Name PAGE: 5 SESS: 17 OUTPUT: Wed Jun 23 13:46:00 2010 1-1/4" (3.2 cm) D. Power Supply Hole 1-1/2" (3.8 cm) D. Water Supply Hole 1-3/4"
(4.4 cm) 36-1/4"
(92.1 cm) 29-1/2" (74.9 cm) 3-3/4" (9.5 cm) Front of Bowl 10-13/16" (27.5 cm) 14-1/2"
(36.8 cm) 25-3/4" (65.4 cm) 38" (96.5 cm) - 66" (167.6 cm) 5-15/16"
(15.1 cm) Remote Dock 13-5/8"
(34.6 cm) 4-3/4" (12.1 cm) 2-5/8"
(6.7 cm) D. 12"
(30.5 cm) 25-1/4"
(64.1 cm) 41" (104.1 cm) -
66" (167.6 cm) Finished Wall 17-7/8"
(45.4 cm) 4-1/16"
(10.4 cm) 2-1/4"
(5.7 cm) 15-5/8"
(39.7 cm) 12"
(30.5 cm) CL Of Outlet Roughing-in - Through-The-Floor Water and Electrical NOTICE: The locations for the supply shut-off, electrical outlet, and docking station cord are suggested locations. Make sure all installations adhere to applicable codes and standards. IMPORTANT! If the supply shut-off is installed directly behind the toilet, the back panel cannot be removed for servicing. Removing the back panel would then require the entire toilet be removed. IMPORTANT! Do not install any items behind the toilet that will interfere with the seat when it is raised. All decorative items should be at least 37 high to allow clearance for the seat. The remote docking station is equipped with a 15 (4.5 M) power cord. The station mounting location shown for the docking station is ADA compliant. The supplied power cord is 56 (142.2 cm) in length. The cord should be installed before the nished wall are installed if possible. The toilet is equipped with a motion sensor to automatically open the seat when movement is sensed. This sensor has a maximum range of 51-1/2 (130 cm). Sensitivity can be adjusted using the User Interface. The toilet is equipped with a motion sensor seat actuator, located on the right side of the toilet. This sensor has a maximum range of 8 (20.3 cm). Keep this area free of obstructions. Supply stop inlet should be 1/2 NPT. Supply stop outlet needs to be 1/2 NPSM. Kohler Co. 5 1132336-2-A JOBNAME: No Job Name PAGE: 6 SESS: 17 OUTPUT: Wed Jun 23 13:46:00 2010 2" (5.1 cm) 8" (20.3 cm) Dock Power Cord Supply Stop GFCI-
Protected Receptacle 6" (15.2 cm) 4" (10.2 cm) 12" (30.5 cm) 1-1/4" (3.2 cm) D. Power Supply Hole 1-1/4"
(3.2 cm) 3" (7.6 cm) 2-5/8"
(6.7 cm) 1-5/8"
(4.1 cm) 1-1/2" (3.8 cm) D. Water Supply Hole Floor Flange Prepare the Site DANGER: Risk of electric shock. Disconnect power before installation or servicing. DANGER: Risk of electric shock. Connect only to a properly-grounded, grounding-type receptacle which is protected by a 120 V, 15 A, 60 Hz Ground-Fault Circuit-Interrupter (GFCI) or Residual Current Device (RCD). Do not remove the grounding pin or use a grounding adapter. DANGER: Risk of electrical shock. For hardwire installations/through-oor electrical supply:
Connect only to a properly-grounded, dedicated circuit protected by an Earth-Leakage Circuit-Breaker (ELCB) or Residual Current Device (RCD). NOTE: The electrical outlet and water supply may also be located behind the toilet. If it is located behind the toilet, the water supply stop must extend no more than 3 (7.6 cm) beyond the nished wall. If located behind the back wall, the supply stop must be a model that connects at a 90 angle. The handle should be easily accessible. NOTE: Locating the supply stop behind the toilet will make it difficult to remove the back panel. It may be necessary to remove the toilet to service items behind the back panel. Install the Dock Power Cord If the nished wall has not been installed, route the docking station power cord. Drill a 3/8 (1 cm) hole in the wall behind the toilet location for the dock cable. If the nished wall is installed, drill a 3/8 (1 cm) hole in the wall behind the toilet location for the docking station power cord. Route the cord to the docking station location. Install the Water Supply 1132336-2-A 6 Kohler Co. JOBNAME: No Job Name PAGE: 7 SESS: 17 OUTPUT: Wed Jun 23 13:46:00 2010 Prepare the Site (cont.) NOTE: The supplied water supply hose is 18 (45.7 cm) in length. The supplied hose must be used for this installation. Install the water supply and supply stop. Install the Electrical Service NOTE: The suppled power cord is 56 (142.2 cm) in length. Locate a dedicated 120 V, 15 A, 60 Hz grounding-type receptacle, protected by a GFCI or RCD, within 56 (142.2 cm) of the back of the toilet. Kohler Co. 7 1132336-2-A JOBNAME: No Job Name PAGE: 8 SESS: 17 OUTPUT: Wed Jun 23 13:46:00 2010 For wall supply installations only. Screw Hole Center the toilet on the template. For through-
the-floor supplies only. Template Top View Prepare the Installation Location IMPORTANT! Risk of product damage. If T-bolts are left in place, they will damage the toilet. Make sure they are removed before moving the toilet into place. If there are T-bolts in the ange, remove them. T-bolts are not required for this installation. Cut out the inside of the ange area on the template. Position the template with the hole positioned over the ange. It is critical that the centerlines marked on the template are centered on the ange. Secure the template to the oor with tape. IMPORTANT! Because of the unique design of this toilet, the width of the bottom edges will vary. The following steps are required because of this variation. Conrm the template is correctly positioned and centered over the ange. Position the toilet on the template. Make sure the front of the base of the toilet is aligned with the markings on the template. Position the toilet so an equal amount of shaded area is visible on each side of the template. Conrm the toilet is centered by measuring the amount of space on each side of the template. Directly under the screw holes on each side of the toilet, accurately mark the bottom edge of the base. The mark should intersect the lines labeled C and A or B on each side of the template. 1132336-2-A 8 Kohler Co. JOBNAME: No Job Name PAGE: 9 SESS: 17 OUTPUT: Wed Jun 23 13:46:00 2010 A C B B C Outside Edge of Toilet A Protective Material A Top View A Determine Mounting Block Location Position a rug or other protective material in front of the toilet. Gently tilt the toilet forward until it rests on the front surface. NOTE: The installation range of the mounting block is marked on the template. Due to variances in the width of the base, the exact location must be determined by the installer. Measure the width of the base, dimension A, on the left side of the toilet. From the mark indicating the outside edge of the base, measure inward and mark dimension A on the template line marked C. Measure the width of the base, dimension B, on the right side of the toilet. From the mark indicating the outside edge of the base, measure inward and mark dimension B on the template line marked C. IMPORTANT! The distance between the outside edges of the mounting block should be the same or slightly less than dimension C. The distance must not be more than 1/16 (2 mm) less than dimension C, or the strength of the mounting block will be compromised. On the template line marked C, measure the distance between the marks that indicate the outside edge of the mounting blocks. Compare this measurement to dimension C. Make sure the mounting blocks are correctly positioned. Position the mounting blocks on the template with the outside edge aligned with the marks made for dimensions A or B. With the side of the mounting blocks running parallel to the lines on the template, mark the entire side of the mounting blocks. With the side of the mounting blocks running parallel to the lines on the template, mark the entire side of the mounting blocks. Kohler Co. 9 1132336-2-A JOBNAME: No Job Name PAGE: 10 SESS: 17 OUTPUT: Wed Jun 23 13:46:00 2010 Determine Mounting Block Location (cont.) At the location of the screw holes in the side of the toilet, measure the width of the opening from the inside edge of each side of the base, dimension C. Use this dimension to conrm the correct location of the blocks. Insert a pencil into each of the four pre-drilled holes in the mounting blocks and mark the center of the holes. Remove the mounting blocks. At the four locations where the centerline in the slots marked on the template and the pencil mark indicating the hole locations meet, drill a 3/16 pilot hole. Remove the template. 1132336-2-A 10 Kohler Co. JOBNAME: No Job Name PAGE: 11 SESS: 17 OUTPUT: Wed Jun 23 13:46:00 2010 Holes Back Cord Opening Screw Red Blue White Black Orange Connector Harness Docking Cord Install the Remote Dock Back Cord Opening Bottom Cord Opening NOTE: The docking station comes with a 15 (4.6 M) cord. Locate the docking station within 15 (4.6 M) of the toilet. Remove the remote control from the dock and set aside. Remove the small screw on the bottom of the docking station. Carefully remove the cover plate. Carefully disconnect the cover plate. Tape the screw to the cover plate and set it aside. For installation using the back cord opening, align the back power cord opening with the power cord hole. For installations using the bottom cord opening, align the docking station with the power cord location, 1 (5.1 cm) below the center of the bottom screw hole, positioned so the cord is hidden when the docking station is installed. Position the docking station in the installation position and mark the screw locations using the dock as a template. Drill appropriate size mounting holes at the screw mounting locations. The size of the hole will depend on need for wall anchors, wall material, and installation requirements. If it has not already been done, run the docking station power cord from the toilet to the installation location of the docking station. Loosen each of the ve small screws located where the wires will be connected. Run the power cord into the docking station. Kohler Co. 11 1132336-2-A JOBNAME: No Job Name PAGE: 12 SESS: 17 OUTPUT: Wed Jun 23 13:46:00 2010 Install the Remote Dock (cont.) Slide the bare end of the wires into the correct port (as shown) and tighten each screw to secure the wires in place. Position the docking station over the wall anchors. Connect the docking station to the wall using two screws. Reconnect the cover plate. Snap the cover plate back into place. Secure the cover plate with the screw. 1132336-2-A 12 Kohler Co. JOBNAME: No Job Name PAGE: 13 SESS: 17 OUTPUT: Wed Jun 23 13:46:00 2010 For wall supply installations only. Hose should face down when through floor. Lag Bolt Wax Ring For through-
the-floor supplies only. Install Mounting Blocks and Wax Ring Position the mounting blocks over the mounting holes. Secure each or the mounting blocks with two lag bolts. Position a wax ring on the outlet. Kohler Co. 13 1132336-2-A JOBNAME: No Job Name PAGE: 14 SESS: 17 OUTPUT: Wed Jun 23 13:46:00 2010 Wall supply installation shown. Docking Station Cord Install the Toilet Position the Toilet Bushing Cap Screw Carefully lower the toilet into place, making sure the water supply line and electrical cord avoid interfering with the toilet when it is in place. Connect the water supply to the supply stop. Connect the docking station. Connect the power. Turn on the water supply. Check for Leaks NOTE: Once the power is connected, the toilet will automatically enter start-up mode. This process takes several minutes. NOTE: If there is a failure during start-up mode, follow the directions on the remote. Once the start-up sequence has been completed ush the toilet. Let the toilet fully rell and check for leaks. Secure the Toilet Secure the toilet to the mounting blocks using the supplied 6 mm x 30 mm screws. Install the caps over the screw holes. 1132336-2-A 14 Kohler Co. JOBNAME: No Job Name PAGE: 15 SESS: 17 OUTPUT: Wed Jun 23 13:46:00 2010 Cover Slot Spring Clip Installation the Back Cover NOTE: Install the cover when the water and power supply are run through the oor. The cover is not designed for use when the water or electrical are connected to wall supplies. Position the cover over the water supply and electrical supply holes. Align the spring clip on the cover with the supply hose inlet. The clip will snap into place on the supply hose inlet to secure the cover. Run the docking station cord through the slot in the cover and snap to cover into place on the supply hose inlet. Kohler Co. 15 1132336-2-A JOBNAME: No Job Name PAGE: 16 SESS: 17 OUTPUT: Wed Jun 23 16:19:01 2010 Check for Correct Operation Make sure the remote is on the docking station. The remote should charge for 30 minutes before the rst use. Press the power button located on the back of the toilet. Press the ush button on the remote. Conrm the toilet ushes. NOTE: After performing these steps, set the clock, date, and other remote functions following the directions in the Homeowners Guide or on-line users guide in the Getting Started section. 1132336-2-A 16 Kohler Co. JOBNAME: No Job Name PAGE: 1 SESS: 1 OUTPUT: Wed Jun 23 13:46:00 2010 1132336-2-A JOBNAME: No Job Name PAGE: 2 SESS: 1 OUTPUT: Wed Jun 23 13:46:00 2010 1132336-2-A JOBNAME: No Job Name PAGE: 3 SESS: 1 OUTPUT: Wed Jun 23 13:46:00 2010 1132336-2-A JOBNAME: No Job Name PAGE: 1 SESS: 1 OUTPUT: Wed Jun 23 13:46:00 2010 USA/Canada: 1-800-4KOHLER Mxico: 001-800-456-4537 kohler.com 2010 Kohler Co. 1132336-2-A
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2010-10-24 | 2405 ~ 2480 | DTS - Digital Transmission System | Original Equipment |
2 | 10544 ~ 10544 | FDS - Part 15 Field Disturbance Sensor |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 2 | Effective |
2010-10-24
|
||||
1 2 | Applicant's complete, legal business name |
Kohler Co.
|
||||
1 2 | FCC Registration Number (FRN) |
0022131643
|
||||
1 2 | Physical Address |
444 Highland Drive
|
||||
1 2 |
Kohler, Wisconsin 53044
|
|||||
1 2 |
United States
|
|||||
app s | TCB Information | |||||
1 2 | TCB Application Email Address |
h******@americantcb.com
|
||||
1 2 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
1 2 |
A2: Low Power Transmitters (except Spread Spectrum) and radar detectors operating above 1 GHz
|
|||||
app s | FCC ID | |||||
1 2 | Grantee Code |
N82
|
||||
1 2 | Equipment Product Code |
KOHLER006
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 2 | Name |
T******** S****
|
||||
1 2 | Title |
Staff Analyst
|
||||
1 2 | Telephone Number |
920-4******** Extension:
|
||||
1 2 | Fax Number |
920-8********
|
||||
1 2 |
t******@kohler.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 2 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 2 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 2 | If so, specify the short-term confidentiality release date (MM/DD/YYYY format) | 04/21/2011 | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 2 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 2 | Equipment Class | DTS - Digital Transmission System | ||||
1 2 | FDS - Part 15 Field Disturbance Sensor | |||||
1 2 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | NUMI Integrated Toilet | ||||
1 2 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 2 | Modular Equipment Type | Does not apply | ||||
1 2 | Purpose / Application is for | Original Equipment | ||||
1 2 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | Yes | ||||
1 2 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 2 | Grant Comments | Power Output listed is conducted. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. | ||||
1 2 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 2 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 2 | Firm Name |
SGS-CSTC Standards Technical Services Co.,Ltd.
|
||||
1 2 | Name |
Z******** Z********
|
||||
1 2 | Telephone Number |
86(0)******** Extension:
|
||||
1 2 | Fax Number |
86021********
|
||||
1 2 |
z******@sgs.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | CC | 2405.00000000 | 2480.00000000 | 0.0016000 | |||||||||||||||||||||||||||||||||||
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
2 | 1 | 15.245 | CC | 10544.00000000 | 10544.00000000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC