LTE-M Cellular Communication Module Data Sheet Publication: 98-2539 Rev AA Landis+Gyr 2020 | Proprietary + Confidential Limitation on Warranties and Liability Information in this document is subject to change without notice. This manual or any part of it thereof may not be reproduced in any form unless permitted by contract or by written permission of Landis+Gyr. In no event will Landis+Gyr be liable for any incidental, indirect, special, or consequential damages (including lost profits) arising out of or relating to this publication or the information contained in it, even if Landis+Gyr has been advised, knew, or should have known of the possibility of such damages. Covered by both issued and pending patents. For further patent information see: https://www.landisgyr.com/about/patent-notices/
2020 Landis+Gyr, Inc. | Proprietary + Confidential Contact Us:
To provide feedback about this document, email us at ustechnicaldocumentation@landisgyr.com Technical Support: 1-888-390-5733 | solutionsupport.na@landisgyr.com 98-2539 Rev AA | LTE-M Cellular Communication Module Data Sheet | May 8, 2020 LTE-M Cellular Communication Module Data Sheet LTE-M Cellular Module Overview The LTE-M Cellular communication module incorporates a power supply, cellular modem, ZigBee circuitry, and interface connector for integration into Landis+Gyr electric meters. A U.FL connector is provided to attach a cellular antenna and the ZigBee antenna is incorporated into the PCB. Data Sheet 98-2539 Rev AA | 3 Figure 1. Landis+Gyr FOCUS AXe and S4x LTE-M Cellular Communication Module Data Sheet The LTE-M Cellular module is not available as a standalone product. The module assembly contains:
LTE-M Cellular module External Flex antenna LTE-M Cellular Module Specifications Table 1. Compatible Meters Category Specification Value or Range Form Class Voltage Units CL100/CL200 120-240 VAC Landis+Gyr E331/E351 FOCUS AXe/AXRe/RXRe Supported Meter Forms Compatible Meters Landis+Gyr E650 S4x Supported Meter Forms 1S 2S 2K 3S 2SE 3SC 4S 12S 1S 2S 2SE 3S 3SC 4S VAC VAC VAC VAC VAC CL200 CL320 CL480 240 240 240 CL10/CL20 120-240 VAC CL 2-20 120-240 VAC CL10/CL20 240 CL100/CL200 120 CL2-200 120-480 VAC CL2-200 240-480 VAC CL3-320 240-480 VAC CL20 CL .2-20 CL .2-20 120-480 VAC 120-480 VAC 120-480 VAC 45S (5S) CL .2-20 120-480 VAC 36S (6S) CL .2-20 120-480 VAC 9S/8S CL .2-20 120-480 VAC 12S 12SE 25S 25SE CL2-200 120-480 VAC CL3-320 120-480 VAC CL2-200 120-480 VAC CL320 120-480 VAC 16/15/14S CL2-200 120-480 VAC 16/15/14SE CL3-320 120-480 VAC 29S CL20 120-480 VAC 10A/8A CL .2-20 120-480 VAC 45A (5A) CL20 120-480 VAC 4 | 98-2539 Rev AA Data Sheet LTE-M Cellular Communication Module Data Sheet Table 2. Electrical, Mechanical and Environmental Category Electrical Mechanical Specification Details Voltage Power Size 11 to 28 VDC 5W peak; .8W continuous 5.06 x 2.87 x .94 Storage Temperature
-40 to +85 Degrees Celsius Environmental Operating Temperature
-40 to +75 Degrees Celsius Relative Humidity 0 to 95% Relative Humidity non-condensing Table 3. Cellular Modem Specification Details Supported Bands 2, 4, 12, 13, 25 Table 4. ZigBee Radio General Specification Details RF Frequency Range 2.405 GHz - 2.475 GHz RF Baud Rate Output Power 250 kbps 19 dBm (Typical) Receive Sensitivity
-104 dBm (Typical) Antenna Type Inverted-F PCB Trace Max Antenna Gain
-3.07 dBi Table 5. Standards Compliance Specification Details FCC Title 47 CFR Part 15 Radiated and Conducted Emissions IEC 61000-4-2, 3, 4, 5, 12, 18 Electromagnetic Compatibility ANSI C12.20 ANSI C12.1 National Standard for Electricity Meters - 0.2 and 0.5 Accuracy Classes Code for Electricity Metering ANSI C37.90.1 (2002) Standard Surge Withstand Capability (SWC) Tests Data Sheet 98-2539 Rev AA | 5 LTE-M Cellular Communication Module Data Sheet LTE-M Cellular Outline The PCB outline is shown below. FCC and Industry Canada Compliance Figure 2. PCB Outline FCC Class B This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the Instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Consult Landis+Gyr or an experienced radio technician for help 6 | 98-2539 Rev AA Data Sheet LTE-M Cellular Communication Module Data Sheet WARNING: Changes or modifications to this device not expressly approved by Landis+Gyr could void the users authority to operate the equipment. RF Exposure This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body. This transmitter must not be co-located or operated in conjunction with any other antenna or transmitter. Cet quipement est conforme aux limites FCC d'exposition aux radiations dfinies pour un environnement non contrl. Cet quipement doit tre install et utilis une distance minimale de 20 cm entre le radiateur et votre corps. Cet metteur ne doit pas tre co-
implants ou exploits en conjonction avec une autre antenne ou metteur. Requirement for Modular Certification The LTE-M Cellular module is approved for use with the inverted-F PCB trace antenna integrated on the board for the ZigBee radio. The LTE-M Cellular module is not available as a standalone product, it is only approved for use in Landis+Gyr products and is not intended for sale to third-party integrators. Additional Testing, Part 15 Subpart B Disclaimer The end product with the LTE-M Cellular module may also need to pass the FCC Part 15 unintentional emission testing requirements and be properly authorized per FCC Part 15 Subpart B. Industry Canada This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (EIRP) is not more than that necessary for successful communication. This radio transmitter (5294A-EG1R1S7) has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list or having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Approved Antennas: Inverted-F PCB Trace, 2.4 - 2.475 GHz, Max Gain -3.07 dBi. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. Conformment la rglementation d'Industrie Canada, le prsent metteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou infrieur) approuv pour l'metteur par Industrie Canada. Dans le but de rduire les risques de brouillage Data Sheet 98-2539 Rev AA | 7 LTE-M Cellular Communication Module Data Sheet radiolectrique l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonne quivalente (p.i.r.e.) ne dpasse pas l'intensit ncessaire l'tablissement d'une communication satisfaisante. Need one more translated paragraph Host FCC Label Requirements The host label(s) must be clearly visible after the device is installed, and display the module FCC ID in the following format:
Contains FCC ID: R7PEG1R1S7 Contains IC: 5294A-EG1R1S7 Contains FCC ID: N7NHL78M Contains IC: 2417C-HL78M This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. Labels Example external labels for the final meter assembly:
CONTAINS FCC ID: R7PEG1R1S7 CONTAINS IC: 5294A-EG1R1S7 CONTAINS FCC ID: N7NHL78 CONTAINS IC: 2417C-HL78 LTE-M FOCUS AXe XXXXXXXX This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. MODULE MODEL: 26-2810 Figure 3. Label Identification ZigBee radio: FCC ID: R7PEG1R1S7, IC: 5294A-EG1R1S7 Cellular modem: FCC ID: N7NHL78M, IC: 2417C-HL78M 8 | 98-2539 Rev AA Data Sheet