Series 5 Network Node N501 & N551 Data Sheet Publication: 98-2386 Rev AA Landis+Gyr 2020 | Proprietary + Confidential Limitation on Warranties and Liability Information in this document is subject to change without notice. This manual or any part of it thereof may not be reproduced in any form unless permitted by contract or by written permission of Landis+Gyr. In no event will Landis+Gyr be liable for any incidental, indirect, special, or consequential damages (including lost profits) arising out of or relating to this publication or the information contained in it, even if Landis+Gyr has been advised, knew, or should have known of the possibility of such damages. Covered by both issued and pending patents. For further patent information see: https://www.landisgyr.com/about/patent-notices/
2020 Landis+Gyr, Inc. | Proprietary + Confidential Contact Us:
To provide feedback about this document, email us at ustechnicaldocumentation@landisgyr.com Technical Support: 1-888-390-5733 | solutionsupport.na@landisgyr.com 98-2386 Rev AA | Series 5 Network Node N551 Data Sheet | 7/9/2020 Series 5 Network Node N501 &
N551 Data Sheet Introduction Landis+Gyrs Series 5 Network Node (RF Mesh - N501 & RF Mesh IP - 551) is key to building a single, integrated IoT network. This product is a fully-functional, Network Interface Card (NIC) that is mPCIe standard-enabled for simple network and sensor device integration. This technology is foundational to Landis+Gyrs industry-leading utility IoT networking solution, Gridstream Connect. Further, the Series 5 Network Node provides the flexibility to grow the value of your IoT platform over time with proven Wi-SUN FAN interoperability as you integrate todays and future AMI or DA networking equipment and third-party IoT devices. Figure 1. Series 5 Network Node N551 Data Sheet 98-2386 Rev AA | 1 Series 5 Network Node N501 & N551 Data Sheet Table 1. Series 5 Network Node N551 Specification Element Radio Model Description Series 5 Network Node N551 Communication Protocol (PHY) IEEE 802.15.4g, IEEE 802.15.4e, IPv6 (RPL & 6LoWPAN) MAC/PHY Features MAC PHY Hardware Capabilities Clock Speed RAM Memory FLASH Memory RF Modulation RF Bands RF Port Automatic selection of best Modulation based on Link Quality Adaptive Power Control (ie. Short range output power back-off) Precision Output Power Management Clear Channel Assessment 120 MHz 640 Kb 2 MB + 4 MB External IEEE 802.15.4 SUN FSK Sub-GHz Single 50 U.FL Male Connector Sub-GHz Band Characteristics: North America Frequency Range (Fc) 902.4 MHz 927.6 MHz Channel Width Number of Channels 400 KHz 64 Multicast Modulation 2-FSK 50 kbps Unicast Modulation Support 2-FSK: 50 200 kbps Data Rate Coverage 50 200 kbps Transmitter Output Power 50 mW 974 mW (peak) Receiver Sensitivity
(IEEE 802.15.4) F2B50 = -107 dBm F2B150 = -101 dBm F2B200 = -100 dBm Sub-GHz Band Characteristics: India Frequency Range (Fc) 865.1 MHz to 866.9 MHz Channel Width Number of Channels 200 KHz 10 Multicast Modulation 2-FSK 50 kbps Unicast Modulation Support 2-FSK: 50 150 kbps Data Rate Coverage 50 kbps 150 kbps Transmitter Output Power 50 mW 974 mW (peak) Receiver Sensitivity
(IEEE 802.15.4) F2B50 = -107 dBm F2B150 = -101 dBm Sub-GHz Band Characteristics: Brazil Frequency Range (Fc) 902-907.5, 915-928 MHz Channel Width 400 KHz 2 | 98-2386 Rev AA Data Sheet Table 1. Series 5 Network Node N551 Specification (Continued) Series 5 Network Node N501 & N551 Data Sheet Element Description Number of Channels 44 Multicast Modulation 2-FSK 50 kbps Unicast Modulation Support 2-FSK: 50 200 kbps Data Rate Coverage 50 kbps 150 kbps 200 kbps Transmitter Output Power 50 mW 974 mW (peak) Receiver Sensitivity
(IEEE 802.15.4) F2B50 = -107 dBm F2B150 = -101 dBm F2B200 = -100 dBm Data Sheet 98-2386 Rev AA | 3 Series 5 Network Node N501 & N551 Data Sheet Table 2. Series 5 Network Node N501 Specification Element Radio Model Description Series 5 Network Node N501 Communication Protocol (PHY) RF Mesh IP (Proprietary) MAC/PHY Features MAC PHY Hardware Capabilities Clock Speed RAM Memory FLASH Memory RF Modulation RF Bands RF Port Automatic selection of best Modulation based on Link Quality Precision Output Power Management 120 MHz 640 Kb 2 MB + 4 MB External 2-FSK, 2-GFSK Sub-GHz Single 50 U.FL Male Connector Sub-GHz Band Characteristics: North America Frequency Range (Fc) 902.3 MHz 927.8 MHz Channel Width 100 KHz, 300 KHz Number of Channels 239 (100KHz Ch width), 86 (300KHz Ch width) Transmitter Output Power 50 mW 974 mW (peak) Receiver Sensitivity
(10% PER, conducted) 9.6 kbps: -114 dBm 19.2 kbps: -112 dBm 19.2 (0.5) kbps: -111 dBm 38.4 kbps: -109 dBm 115.2 kbps: -104 dBm 4 | 98-2386 Rev AA Data Sheet Series 5 Network Node N551 Outline The PCB outline is shown below. Series 5 Network Node N501 & N551 Data Sheet Figure 2. Board Outline 1 Data Sheet 98-2386 Rev AA | 5 Series 5 Network Node N501 & N551 Data Sheet Figure 3. Board Outline 2 FCC, Industry Canada Compliance FCC Class B This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
This device may not cause harmful interference, and This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the Instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Consult Landis+Gyr or an experienced radio technician for help. WARNING: Changes or modifications to this device not expressly approved by Landis+Gyr could void the users authority to operate the equipment. RF Exposure This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 33 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. 6 | 98-2386 Rev AA Data Sheet Series 5 Network Node N501 & N551 Data Sheet Cet quipement est conforme aux limites d'exposition aux radiations FCC dfinies pour un environnement non contrl. Cet quipement doit tre install et utilis une distance minimale de 33 cm entre le radiateur et votre corps. Cet metteur ne doit pas tre situ proximit ou fonctionner en conjonction avec toute autre antenne ou metteur. Requirement for Modular Certification N551 network node is approved for use with the antenna listed below. Antenna types not included in the list below or a having higher gain than the maximum indicated for that type, are prohibited for use with this device. The antennas approved for use with the device:
Industry Canada Manufacturer: Airgain MPN: ET960NPMR2 Type: Dipole, omni-directional Peak Antenna Gain: 5.7 dBi Information on Test Modes and Additional Testing Requirements A diagnostic test mode is available to device integrators that allows control of the transmitter in order to execute FCC 15.247 compliance testing. This mode of operation provides a basic command interface over a dedicated serial port. Further information on how to enable this mode of operation and a description of the command interface is available to device integrators upon request and under NDA. Additional Testing, Part 15 Subpart B Disclaimer The end product with an embedded N551 Network Node may also need to pass the FCC Part 15 unintentional emission testing requirements and be properly authorized per FCC Part 15 Subpart B. This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. This radio transmitter (5294A-NG0R1S5) has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Approved Antennas: Airgain, ET960NPMR2, Dipole, omni-directional, Peak gain: 5.7 dBi. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. Data Sheet 98-2386 Rev AA | 7 Series 5 Network Node N501 & N551 Data Sheet Conformment la rglementation d'Industrie Canada, le prsent metteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou infrieur) approuv pour l'metteur par Industrie Canada. Dans le but de rduire les risques de brouillage radiolectrique l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonne quivalente (p.i.r.e.) ne dpasse pas l'intensit ncessaire l'tablissement d'une communication satisfaisante. Le prsent metteur radio (5294A-NG0R1S5) a t approuv par Industrie Canada pour fonctionner avec les types d'antenne numrs ci-dessous et ayant un gain admissible maximal et l'impdance requise pour chaque type d'antenne. Les types d'antenne non inclus dans cette liste, ou dont le gain est suprieur au gain maximal indiqu, sont strictement interdits pour l'exploitation de l'metteur. Regulatory Compliance Brazil Anatel Model: N551 ANATEL ID: 08239-19-10267 Este equipamento no tem direito proteo contra interferncia prejudicial e no pode causar interferncia em sistemas devidamente autorizados. Host FCC Label Requirement In the final installation, the following information must be visible:
Contains FCC ID: R7PNG0R1S5 Contains IC: 5294A-NG0R1S5 Model: N551/N501 This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
This device may not cause harmful interference. This device must accept any interference received, including interference that may cause undesired operation. 8 | 98-2386 Rev AA Data Sheet