Certification Exhibit FCC ID: R7PSSMM1TRP FCC Rule Part: 15.247 ACS Project Number: 11-0372 Manufacturer: Landis+Gyr Technology, Inc. Model: Elster Solid State Meter Module Manual 5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 Elster Solid State Meter Module Quick Start Guide Publication: 98-1258 Rev AB LANDIS+GYR CONFIDENTIAL INFORMATION Draft 12/8/2012 Limitation on Warranties and Liability Information in this document is subject to change without notice. This manual or any part of it thereof may not be re-
produced in any form unless permitted by contract or by written permission of Landis+Gyr. In no event will Landis+Gyr be liable for any incidental, indirect, special, or consequential damages (including lost prof-
its) arising out of or relating to this publication or the information contained in it, even if Landis+Gyr has been advised, knew, or should have known of the possibility of such damages. Other brands or product names used are the trademarks or registered trademarks of their respective holders. 2012 Landis+Gyr, Inc. All Rights Reserved Elster Solid State Meter Module Quick Start Guide Publication: 98-1258 Modification Date Revision Description Author 9/10/2012 12/3/2012 AA AB Released In Process Vicky Costello Vicky Costello Revision History Landis+Gyr 30000 Mill Creek Avenue, Suite 100 Alpharetta, GA 30022 Website: www.landisgyr.com E-mail: solutionsupport.na@landisgyr.com Technical Support: 1-888-390-5733 Copyright 2012 Landis+Gyr All rights reserved. Draft 12/8/2012 Elster Solid State Meter Module Quick Start Guide Overview The Landis+Gyr Solid State Meter Module (SSMM) is designed to provide active energy (Kilo-Watt hour) data from Elster ALPHA Plus meters for use in residential and industrial commercial services. Figure 1 - 1. Elster Solid State Meter Module The meter kit includes:
Elster ALPHA Plus meter (A1D+ or A1T+) Communication Module (SSMM) Antenna Landis+Gyr Confidential Information 98-1258 Rev AB 3 Draft 12/8/2012 Elster Solid State Meter Module Quick Start Guide Landis+Gyr Required Software To work with the endpoint, you need at least one of the following software tools and documentation:
UtiliNet Solution Center (USC) Meter Master Lite software Meter Master Lite Quick Start Guide, publication number 98-0071 Elster ALPHA Plus software Landis+Gyr recommends you have RF Verify software and the RF Verify User Guide, publication number 98-0069. Labels The endpoint contains the following labels:
1 2 3 Figure 2. Label Identification Table 1. Elster Label Identification Label Description 1 Elster Meter Name Plate 2 3 Landis+Gyr FCC ID Landis+Gyr LAN ID AEP compliant bar code that defines meter manufacturer, form, base, test voltage and current, watt-hour constant, serial number, and customer specific information. Manufacturer or customer specified serial number Manufacturer model and style number Federal Communications Commission (FCC) Identification (ID) number assigned to the Landis+Gyr Solid State Meter Module for use in the Elster Alpha+ meter. Identifies the Solid State Meter Module to the Landis+Gyr billing network (printed and barcoded). 4 98-1258 Rev AB Landis+Gyr Confidential Information Draft 12/8/2012 Landis+Gyr LAN ID Elster Solid State Meter Module Quick Start Guide The LAN ID is a unique identifier for each Landis+Gyr endpoint. Landis+Gyr provides the LAN address. You cannot change the LAN ID of a radio. Features and Functions Endpoint Registration The endpoint is automatically registered with the host system. No special tools are needed during installation. Admin packets are sent once each hour at a random time during the hour and play a crucial role in the automatic discovery of a meter by the Landis+Gyr system. They tell what kind of meter the module interfaces with, and other characteristics, such as the scaling constant, number of dials, and the firmware version. Admin packets include:
Meter ID Protocol ID Scaling Constant Number of dials Table 2. Admin Packet Information Identifies the customer Identifies the type of meter. Tells how to convert meter readings into real units such as kWh Also referred to as displayed digits. Maximum Sensor Change Rate Tells how much the meter reading can change in a certain period of time. Firmware Version Specifies the firmware revision number. Current Cumulative Reading from the meter Communication and Retrieving Data A microprocessor on the communications module counts pulses, records usage over multiple intervals, and transmits the information to the head end system. Several different packet types are sent.The most frequently sent packet contains the current rotational count and historical interval data that is useful for load profiling and time-of-use metering. Another less frequently sent (Admin) packet contains the current cumulative rotation count, useful for basic automatic meter reading applications. An Admin packet is sent once hourly and contains the information listed in Table 2, Admin Packet Information, on page 5. Power Outage/Restoration When an outage occurs, the meter uses an early power failure signal to alert the communication module. The communication module saves critical endpoint data to non-volatile memory, creates and sends a power fail message to the host system that includes the LAN ID. When power is restored, the communication module sends a Power Up message to the host system. This message includes the following information:
Landis+Gyr Confidential Information 98-1258 Rev AB 5 Draft 12/8/2012 Elster Solid State Meter Module Quick Start Guide Landis+Gyr LAN ID Total count Last ten interval counts Customer Service Contact Landis+Gyr Customer Support at solutionsupport.na@landisgyr.com or call 888-390-5733 with any questions or problems for guidance through the troubleshooting process. Compliance FCC Class B This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the Instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the antenna. Increase the separation between the equipment and receiver. Consult Landis+Gyr or an experienced radio technician for help. U WARNING: Changes or modifications to this device not expressly approved by Landis+Gyr could void the users authority to operate the equipment. 6 98-1258 Rev AB Landis+Gyr Confidential Information Draft 12/8/2012 Landis+Gyr RF Exposure Elster Solid State Meter Module Quick Start Guide In accordance with FCC requirements of human exposure to radio frequency fields, the radiating element shall be installed such that a minimum separation distance of 20 centimeters will be maintained. Host FCC Label Requirement In the final installation, the following information must be visible:
Contains FCC ID: R7PSSMM1TRP This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation. Landis+Gyr Confidential Information 98-1258 Rev AB 7 Draft 12/8/2012 Elster Solid State Meter Module Quick Start Guide Landis+Gyr Product Specifications Table 3. Elster Solid State Meter Module Specifications Category Specification Value or Range Form Class Compatible Meters Elster ALPHA Plus Supported Meter Forms NOTE: Contact Elster Electricity for additional forms. 1S 1S 2S 2S 3S 4S 35S 35A 12S 12S 13S 13S 13A 36S 36A 9S 10S 10A 16S 16S 16A 200 320 200 320 20 20 20 20 200 320 200 320 100 20 20 20 20 20 200 320 100 Electrical RF Voltage Input Current Output Power 13.5VDC + 1V, 50mA (limited duration from meters power supply) 50mA 22-26.5 dBm Transmit Frequency 917.58 MHz (Fixed)) 8 98-1258 Rev AB Landis+Gyr Confidential Information Draft 12/8/2012 Landis+Gyr Elster Solid State Meter Module Quick Start Guide Table 3. Elster Solid State Meter Module Specifications Category Specification Value or Range FCC Title 47 CFR Part 15 Subpart B & C Radiated and Conducted Emissions IEC 61000 4-2,3,4,5 Electromagnetic Compatibility Standards Compliance ANSI C12.1-2011 ANSI C12.20-2002 ANSI C37.90.1 ANSI/IPC-A-610-Class 2 General Environmental Environmental Operating Temperature Range Humidity Size (Meter & Module) Weight (Meter & Module) Mechanical Electricity Metering Electricity Meters Standard Substation Standards - Fast Transient and Oscillatory Waveform Workmanship Standard for Electronic Assemblies Outdoor, rain-protected, sunlight-exposed
-40 to +85 C (under meter glass) 10% to 95% relative humidity, non-condensing Refer to Elster Technical Manual, TM42-2182E for more details. Refer to Elster Technical Manual, TM42-2182E for more details. Landis+Gyr Confidential Information 98-1258 Rev AB 9 Draft 12/8/2012 Elster Solid State Meter Module Quick Start Guide Landis+Gyr Physical Dimensions The ALPHA Plus meter fits all standard S-base services. Meters with an A-base are also available. Figure 1 - 1 illustrates the S-base meter type and dimensions. NOTE: The dimensions are for reference purposes only and should not be used for construction. Figure 1 - 1. S-base Meter Type and Dimensions in Inches (millimeters) - Front and Side View Figure 1 - 2 and Figure 1 - 3 illustrate the A-base meter type and dimensions. 10 98-1258 Rev AB Landis+Gyr Confidential Information Draft 12/8/2012 Landis+Gyr Elster Solid State Meter Module Quick Start Guide Figure 1 - 2. A-base Meter Type and Dimensions in Inches (millimeters) - Front and Side View Figure 1 - 3. A-base Meter Type and Dimensions in Inches (millimeters) - Back View Landis+Gyr Confidential Information 98-1258 Rev AB 11 Draft 12/8/2012 Elster Solid State Meter Module Quick Start Guide Landis+Gyr 12 98-1258 Rev AB Landis+Gyr Confidential Information Draft 12/8/2012