Single Pole (One Location) Wireless Occupancy Sensor Products Cat. No. WSS10, WSC04, WSC15, and WSS0S Incandescent 800W @ 120V Ballast 1200VAC @ 120V, 2700VA @ 277V 120-277VAC, 50-60Hz, Motor: 1/4 HP @ 120V InStallatIOn InStructIOnS WarnInGS anD cautIOnS:
To be installed and/or used in accordance with appropriate electrical codes and regulations. WSS0S Wireless Remote Switch can be used for additional switches (3-way and 4-way), no wires necessary. If you are unsure about any part of these instructions, consult a qualified electrician. WarnInGS anD cautIOnS:
Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture. Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL. Recommended minimum wall box depth is 2-1/2. tools needed to install your Switch:
Electrical Tape Slotted/Phillips Screwdriver Pencil Cutters Wire Nuts changing the color of your Switch:
Color change kits are available from Leviton. To change color of frame, proceed as follows:
Pliers Ruler Step 3a Single Pole Wiring application:
nOtE: For 3-way applications, 4-way and more, use the WSS0S Wireless Remote. Step 3b cont'd WIrInG SWItcH:
connect wires per WIrInG DIaGraM below as follows:
Connect (Hot) wire from wall box to black wire on switch. Connect (Load) wire in wall box to blue wire on switch. Connect (Neutral) wire in wall box to white wire on switch. nOtE: For NO Neutral model, white wire will not be available. White Wire (WH) Dip Switches 1-4 Push in side at tab to release line up tabs and press in side to attach InStallInG YOur SWItcH nOtE: Use check boxes when Steps are completed. Step 1 WarnInG: tO aVOID FIrE SHOcK Or DEatH; turn OFF POWEr at circuit breaker or fuse and test that power is off before wiring!
Black Wire (BK) B K W H 1 2 4 3 Blue Wire (Bl) Swit c h
Step 2 Identifying your wiring application (most common):
nOtE: If the wiring in your wall box does not resemble this configuration, consult a qualified electrician. 2 1 3 4 Single Pole 1. Line (Hot) 2. Neutral 3. Ground 4. Load WH BK Hot (Bla c k ) BL Bla c k Load White Line 120 V A C , 60H z Neutral (White) Step 3b Single Pole Wiring application:
nOtE: To access dip switch settings, lift up the bottom of the switch pad. DIP SWItcH SEttInGS:
Manual ON / Auto ON mode: (factory: manual mode) Occupancy Sensor WSC** - Auto mode can be enabled with the use of additional (3) AAA batteries or a 5-24VDC connection. Walk-through: On or Off (can be used only in Auto-ON mode) Timeout: 2, 10, 20, 30min Dip Switch 1 2 Dip Switch SettingS OFF position Auto ON/Manual OFF Walk Through OFF 2 Min time-Out OFF position 3 4 X X On position Manual ON Walk Through ON On position
10 Min time-Out OFF position On position 3 4 X
X 20 Min time-Out OFF position On position 3 4
X X
30 Min time-Out OFF position On position 3 4
X X Factory Settings: The sensor is shipped from the factory to work in almost all situations, without any adjustments. The factory settings are: Manual mode, when entering the room, the wireless momentary switch will need to be turned ON. Wireless occupancy sensor will keep the lights on until the room is vacant then turn the lights OFF after timeout period. The PIR technology is active. Factory time-out is 10 min. Time-Outs: The Sensor has four time-out settings: 2, 10, 20, or 30 min. Fixed Time-Out: The value of this time-out is user selected through the use of the Dip Switch Settings. Walk-Through Time Delay: The walk-through feature, which is only active in the Auto-On mode, is useful when a room is momentarily occupied. With this feature, the Sensor will turn the lights OFF shortly after the person leaves the room. The walk-through feature works in the following manner: When a person enters the room, the lights will turn ON. If the person leaves the room before the walk-through time-out of 2.5 minutes, the Sensor will turn the lights OFF within 2.5 minutes of no occupancy detected. If the room is occupied for longer than 2.5 minutes, the Sensor will enter the Occupied Mode with the time-out duration specified by the Dip Switch setting. Step 3b cont'd Cat. No. WSS10 has a single switch pad that toggles the relay and its corresponding load, ON and OFF. If the relay is OFF, the relay will turn ON when the push-button is pressed, and remain ON in the presence of motion. In the absence of motion, the Sensor Unit will Time-Out and turn relay OFF. If in Auto ON/Manual OFF, time delay will start once space is vacant. nOtES:
When the lights are on, the Motion Indicator LED will blink red (1 blink per minute) every time motion is detected. When the Time-Out expires and the relay turns OFF, a 30 second vacancy confirmation exists to turn the relay back ON. In Manual-ON mode, the button must be pressed to turn the lights ON. In the absence of motion, the unit will Time-Out and turn the lights OFF. lEarn MODE:
When using the Wireless Occupancy Products together, they must LEARN the other devices to perform as desired. WSC04 and WSC15 Wireless Occupancy Sensor has learn button on device, under front plastic tab WSS10 Wireless Momentary Control Switch use switch pad for learning WSS0S Wireless Remote Switch use switch pad for learning When in programming mode, 1 AMBER LED flash, 1 second pause = in programming Programming using Momentary Switch (WSS10) To enter programming, press and hold the switch pad for 15 seconds There are 2 modes in programming, LEARN and CLEAR modes. Tap the switch pad to select which mode you would like. 1 AMBER LED flash = LEARN mode 2 AMBER LED flashes = CLEAR mode Once you have selected the desired programming mode, press and hold the pad again for 5 seconds to ENTER the desired mode. Learn mode:
1 Red flash = no learned devices 1 Green flash = 1 learned devices 2 Green flashes = 2 learned devices 3 Green flashes = 3 learned devices Etc. (up to 6 devices) On remote switch or occupancy sensor, you must press the switch pad to send a signal for learning. AMBER LED on for 2 seconds = acknowledgement, device is learned GREEN LED on for 2 seconds = device is unlearned Step 3b cont'd Clear Mode 1 Red flash = no learned devices 1 Green flash = devices exist Press and hold the switch pad for >5 seconds. After the button is released, the LED will flash red to confirm all learned devices have been installed. Proceed to Step 4. nOtE: Product will leave the learn or clear modes, without change, after 20 seconds of inactivity. Step 4 testing your Switch prior to mounting in wall box:
Step 6 restore Power:
Restore power at circuit breaker or fuse. Installation is complete. Position all wires to provide room in outlet wall box for device. OPEratIOn Ensure that the word TOP is facing up on device strap. Partially screw in mounting screws in wall box mounting holes. For additional information, contact levitons techline at 1-800-959-6004 or visit levitons website at www.leviton.com Covered by one or more US & Foreign Patents and patents pending Copyright 2008 Leviton Manufacturing Co., Inc. All Rights Including Trade Dress Rights Reserved Fcc cOMPlIancE StatEMEnt This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by Leviton could void the user's authority to operate this equipment. nOtE: The locator light will illuminate when the load is in the OFF position to facilitate access in the dark. Charge time: 2-4 minutes depending on strength of light source Occupancy Sensor minimum light requirement: 40 LUX Min 25W (No neutral version) Auto ON: will function with out (3) AAA batteries for 24-48 hours. For extended Auto ON feature, be sure to use batteries or 5-24VDC power connection. Push Pad (Default settings) turn On from OFF position:
Tap Lights turn ON. turn OFF from On position:
Tap Lights turn OFF. cleaning: Clean with a damp cloth. DO nOt use chemical cleaners. L E A R N R A N G E WSc04/WSc15 nOtE: Dress wires with a bend as shown in diagram in order to relieve stress when mounting device. Restore power at circuit breaker or fuse. Press pad until locator light is OFF. Lights should turn ON. If lights do not turn On, refer to the trOuBlESHOOtInG section. Step 5 Switch Mounting:
turn OFF POWEr at cIrcuIt BrEaKEr Or FuSE. Installation may now be completed by tightening mounting screws into wall box. Attach wallplate. Push Pad locator light trOuBlESHOOtInG lights Flickering
- Lamp has a bad connection.
- Wires not secured firmly under terminal screws of switch and/or remote. light does not turn On and locator lED does not turn On
- Circuit breaker or fuse has tripped.
- Lamp is burned out.
- Lamp Neutral connection is not wired. WSS10 WSS0S Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Levitons only obligation is to correct such defects by repair or replacement, at its option, if within such five year period the product is returned prepaid, with proof of purchase date, and a description of the problem to leviton Manufacturing co., Inc., att: Quality assurance Department, 59-25 little neck Parkway, little neck, new York 11362-2591. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. there are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise. lIMItED 5 YEar WarrantY anD EXcluSIOnS PK93663-10-00-0A FOLD SCHEME 14"
LEVI T ON INSTRUCTION SHEET/MANUA L SPECIFIC A TION S PK93663-10-00-0A DI-000-VZS15-02C 8.5"
Cat No. Black Helvetica 40 Lb. o f fse t Paper size:
Overall size: 14" X 8.5"
Final fold size:
2.3" X 4.25"
DOCUMEN T A TIO N 7095512 CD8 H2D 11/06/08 10/04/07 4.25"
2.3"
Cat No. FINAL Fold Line