Accessories Quick Start Guide Flexible Linear Lighting System The versatile indoor and outdoor water resistant lighting solution. CabLED Accessories Dimension Inline ON/OFF Dimmer Switch RF Light/Motion Sensor Install Inline ON/OFF Dimmer Switch Connect Inline ON/OFF Dimmer Switch Connects to PS-Link Connector. Oers full dimming range, fades the CabLED system on and o at last selected dimming level. Wireless 2.4 GHz Light/Motion Sensor activates CabLED system by sensing motion, light or both. Must be used with at least one RF Receiver and can be synchronized with up to ten RF Receivers. The Inline ON/OFF Dimmer Switch ts between the PS-Link Connector and the power supply. Unplug the power supply from the AC outlet before connecting. Match the icons on the PS-Link Connector with the icons on the Inline Dimmer. 50mm 23mm 67mm 68mm 78.5mm 115.5mm Front view Side view Back view RF Receiver for RF Remote Dimmer OR RF Light/Motion Sensor 2.4 GHz RF Receiver connects to PS-Link Connector and can be synchronized with either the Remote Dimmer OR Light/Motion Sensor.
! Maximum length of CabLED CANNOT be over 25m. Front view Side view Back view CabLED Strip Specication Mount Inline ON/OFF Dimmer Switch Power Button: On/O Light Bar Indicator:
Level 5 (max) (shown) Level 4 Level 3 Level 2 Level 1 (min) Dimming Bar:
+: Increase light level
- : Decrease light level Position Inline ON/O Dimmer Switch between power supply and PS-Link Connector. The Inline Dimmer uses a keyhole mounting system designed to be mounted vertically. A Screw M4 screw partially into surface, leaving 1/4 inch to hang the Inline Dimmer. B Fit center of keyhole in back of Inline Dimmer over screw and slide down to mount.
Disconnect Inline Dimmer from power supply before mounting. Install RF Remote Dimmer The wireless Remote Dimmer works only with CabLED Receivers. Both the Dimmer and Receiver are rated IP65, completely weather resistant but not to be submerged in water. You may use one Dimmer to control up to ten CabLED systems, each connected to its own CabLED Receiver. The Dimmer MUST be synchronized with each Receiver. Install RF Remote Dimmer Unplug the power supply from the AC outlet before connecting. Install the receiver between the power supply and the PS-Link Connector by matching the icons on the plugs. 50mm 39mm 102mm Model Name Input Voltage Standby Current Model Name Input Current Input Power RF Distance Detection Angle Detection Distance IP Rating Model Name Operating Temp. Model Name StorageTemperature Inline ON/OFF Dimmer Switch RF Receiver RF Remote Dimmer RF Light/Motion Sensor 24V 15mA 4A/25m 96W/25m
26V 50mA 4A/25m 96W/25m 30m
3V 33uA 15mA 99uW 30m
3V 50uA 20mA 150uW 30m 160o 12m IP65
-20o ~ 50o 0o ~ 80o Front view Side view Back view CabLED Acessories Layout Weight 85g 120g 85g 85g RF Remote Dimmer Wireless 2.4 GHz Remote Dimmer fades CabLED system on/o, oer full dimming range and retains last dimming level. Must be used with at lease one RF Receiver and can be synchronized with up to ten RF Receivers This diagram illustrates possible layouts for the CabLED 8000 Series Accessories. Refer to the Component Overview for additional information. Optional Accessories Optional 1 Inline ON/OFF Dimmer Switch OR S P P P P P Power Supply Optional 2 50mm 27mm 110mm 10.7mm 20mm 30mm AC Outlet Front view Side view Back view RF Receiver AND OR Connectors P S PS-Link Connector 4 Way Power Splitter Plug the power supply into the AC outlet to synchronize it to the Remote Dimmer. Front view Side view Back view RF Remote Dimmer RF Light/motion Sensor Install RF Remote Dimmer (Continued) Install RF Light/Motion Sensor Install Battery in the RF Remote Dimmer Open the back cover of the Remote Dimmer and Insert 2 AAA batteries matching the polarity (+ and -) markings on the batteries with the indicators in the battery compartment. The wireless Motion Sensor works only with CabLED Receivers. Both the Dimmer and Receiver are rated IP65, completely weather resistant but not to be submerged in water. You may use one Dimmer to control up to ten CabLED systems, each connected to its own CabLED Receiver. The Sensor MUST be synchronized with each Receiver. Install RF Remote Dimmer Unplug the power supply from the AC outlet before connecting. Install the receiver between the power supply and the PS-Link Connector by matching the icons on the plugs. Mount RF Light/Motion Sensor A Position base for Motion Sensor at the entrance of the area to be lit. Secure with two M3 screws. A Fit ring on back of Motion Sensor onto base and partially screw together. S y n c A Adjust the Sensor to desired angle. A Tighten ring completely to secure. Synchronize One RF Receiver with RF Remote Dimmer A Unlock the receiver case and open it to access the sync switch. Move the power button to AUTO. Use a pin or straightened paper clip to push the sync button. Plug the power supply into the AC outlet to synchronize it to the Remote Dimmer.
! Maximum length of CabLED CANNOT be over 25m. tilt side to side
+/- 31.5 tilt up 31.5 or down 25 Mount RF Receiver unlocked position Push switch to AUTO Off On Auto Off On Auto Sync Off On Auto B Open the battery compartment on the back of the Remote Dimmer to access the sync switch. Use a pin or straightened paper clip to push the sync button. Install Batteries in the RF Light/Motion Sensor Open the front battery compartment cover using a at screw driver. Insert 2 AAA batteries matching the polarity (+ and -) markings on the batteries with the indicators in the battery compartment. Off On Turn ON to test NOTE: Maximum synchronize 5 Motion Sensors and Remotes Dimmer with one Receiver in total. AAA AAA Sync Sync When the CabLED strip start blinking, the Remote Dimmer is successfully synchronized with the Receiver. Blue LED blink if not success synchronized in 30 sec. Press Sync button 6 sec in paring to reset. Synchronize One RF Receiver with RF Light/Motion Sensor A Unlock the receiver case and open it to access the sync switch. Move the power button to AUTO. Use a pin or straightened paper clip to push the sync button. blue LED light up when low battery Power Button: On/O Blue LED: Lights when in use Dimming Bar:
+: Increase light level
- : Decrease light level unlocked position Push switch to AUTO Off On Auto Off On Auto Sync Off On Auto Mount RF Remote Dimmer A Secure base with two M3 screws. Insert hook into base at an angle and then push to snap into place. B Insert hook at angle. B With the battery compartment on the front of the Light/Motion Sensor, access the controls. Turn the power ON. Use a pin or straightened paper clip to push the sync button. 10 mins 20 mins 5 mins Off On 30 sec 30 mins Sync Off On Sync When the CabLED strip start blinking, the Motion Sensor is successfully synchronized with the Receiver. Press Sync button 6 sec in paring to reset. red LED blinks for low battery NOTE: Maximum synchronize 5 Motion Sensors and Remotes Dimmer with one Receiver in total. 10 mins 20 mins 5 mins Off On 30 sec 30 mins Sync C Hang remote onto hook. Set the RF Light/Motion Sensor Adjust the time delay and ambient light setting by using a at screw driver. Turn each dial until the arrow points to desired setting. 10 mins 20 mins 5 mins Off On 30 sec 30 mins Sync arrow points to current setting 10 mins 20 mins 5 mins 30 sec 30 mins The time delay will determine how long the strip will be lit after the sensor is activated. There are ve settings, between 5 seconds and 30 minutes. The ambient light photocell setting detects the amount of natural light, it can be set to interact with Motion activities. NOTE: The ambient light control can be set between complete darkness (minimum) and moderate (maximum). Adjust the setting and test it outside until you have reached the desired level of darkness needed before the strip is activated by motion. Follow these instructions to mount each RF Receiver to be used with either the Remote Dimmer or the Light/Motion Sensor. Mount Horizontally A A Screw two M4 screw partially into surface, leaving 1/4 inch to mount the receiver. Fit center of keyholes in back of receiver over each screw and slide to one side to secure. Mount Horizontally A Screw two M4 screw partially into surface, leaving 1/4 inch to mount the receiver. A Fit center of keyholes in back of receiver over each screw and slide to one side to secure.
Disconnect Receiver from power supply before mounting. IMPORTANT: The CabLED 8000 system is designed to work ONLY with the power supplies, connectors, mounting options, and accessories listed. Do NOT substitute other products as they may damage your system. IMPORTANT: Do not plug into outlet until power supply is secured. Place power supply near outlet and o the ground so there is no chance of it being submerged in water. IMPORTANT: There is only one way to connect the PS-Link Connector to the power supply. Make certain the icons match before connecting. Connect the power supply to the PS-Link Connector BEFORE plugging the power supply into the AC outlet. IMPORTANT: Risk of re or electric shock - Do not use where directly exposed to water. IMPORTANT: To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. IMPORTANT: This product is not suitable for mounting on a ammable surface. IMPORTANT: Do not install when it is raining.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1)This device may not cause harmful interference and (2)This device must accept any interference received, including interference that may cause undesired operation. POWER SOURCE Do not modify the plug provided with the product If it will not t the outlet, have a proper outlet installed by a qualied electrician. Damaged or deformed power cords are hazardous and should be replaced immediately by a qualied service technician. OPERATION Unplug the unit and the AC power adapter from the electrical outlet during electrical storms or when unused for long periods of time to prevent damage. LOCATION Place accessories well above the ground or in an area they will NOT be submerged in water or other liquids. Keep all components away from extreme heat sources such as heating vents, radiators, electric heaters and re pits. INSTALLATION Products should be installed in accordance with the user manual, current electrical codes and/or the current National Electric Code (NEC). To avoid electrical shock and/or damage to the system, do not handle the components with wet hands. Do not use if there is any damage to the light or cord insulation. Inspect periodically. CLEANING Clean only with a dry or slightly damp cloth. Do not use any acid or alkaline liquids, cleansing agents or solvents. Unplug the system from the wall outlet before cleaning. SERVICE Always remove the AC power adapter from the electrical outlet before adjusting or inspecting the system. Inspect your system periodically. Do not open the cabinets of accessories or power supply. There are no user-serviceable parts. Opening the cabinets may present a shock hazard, and any modication to the product will void your warranty.
*Technical data are based on optimum conditions and actual performance may vary. Warranty : Please contact local Optiled office or distributors for more information. Email: info@optiled.com Website: www.optiled.com The logo is a registered trademark. The logo is a registered trademark. The logo is a trademark. 2011 OPTILED, all rights reserved. Country of origin : China IP65 N25615 MKT-473/04/11