FCC ID: 2AI4G-TR-250DC-SS Underwater dock light controller

by: LLW Enterprise LLC latest update: 2023-10-26 model: TR-250DC-SS

One grant has been issued under this FCC ID on 10/26/2023 (this is one of two releases in 2023 for this grantee). Public details available include internal & external photos, manuals, and frequency information. some products also feature user submitted or linked troubleshooting guides, warrantee terms, drivers, password defaults, & instructions.
permalink for this FCC identifier
search for: Repair details
from iFixIt
Replacement
on Amazon
Trade-in? Recycling locations
eg is reader-supported. when you buy through links on our site, we may earn an affiliate commission.
|
Get Slack Alerts
|
|   
eg for Slack usage
manual photos label
app s submitted / available
1 Users Manual pdf 951.79 KiB October 26 2023
1 Internal Photos pdf 1.41 MiB October 26 2023
1 External Photos pdf 375.42 KiB October 26 2023
1 ID Label/Location Info pdf 129.58 KiB October 26 2023
1 Attestation Statements pdf 75.72 KiB October 26 2023
1 Block Diagram Block Diagram pdf October 26 2023 confidential
1 Circuit Diagram Schematics pdf October 26 2023 confidential
1 Cover Letter(s) pdf 28.51 KiB October 26 2023
1 Cover Letter(s) pdf 19.14 KiB October 26 2023
1 RF Exposure Info pdf 192.78 KiB October 26 2023
1 Technical Description Operational Description pdf October 26 2023 confidential
1 Test Report pdf 85.76 KiB October 26 2023
1 Test Setup Photos pdf 290.37 KiB October 26 2023

 

INSTALLATION INSTRUCTIONS VOLT Dock Light Controller Help Hotline:

1-813-978-3700 Mon-Fri 8am-8pm Sat-Sun 10am - 6pm (EST) Specifications and product details subject to change without notice. Copyright 2022, VOLT Lighting, Lutz FL USA 33549 All rights reserved. [email protected] 813.978.3700

- 1 -

INSTALLATION INSTRUCTIONS VOLT Dock Light Controller

Important: Please Read Before Installation Low voltage installation and maintenance is safe and presents no risk for electric shock injury. However, there are regulations that may apply and that should be followed by installers. The following safety points may or may not be included in these regulations - the installer is responsible for ensuring a compliant installation. These instructions do not intend to cover all variations in installation, operation maintenance or mounting situations. 1. WARNING- RISK OF SHOCK. Install power unit at least 10 feet (3m) from water. 2. WARNING- install power unit in or on non-combustible materials only. 3. Power supply must be connected (using supplied power cord) to GFCI protected receptacle with an In-use cover. 4. All power supplies are indoor and outdoor rated, but we recommend that the controller be mounted outdoors. If mounting indoors, check for local electrical codes that may apply. 5. Power supply must be mounted in a vertical orientation with the bottom plate at least 1 foot above the ground. 6. In hot climates, avoid mounting in direct sunlight. Power unit will get hot regardless of climate. This is normal for operation.

Important: Please Read Before Installation WARNING Risk of Electric Shock. Install power unit 10 feet (3m) or more from water surface. Where the power unit is installed outdoors, connect power unit to a receptacle protected by a GFCI. CAUTION: FOR USE ONLY ON A BRANCH CIRCUIT PROTECTED BY A CLASS A TYPE GROUND FAULT CIRCUIT INTERRUPTER FOR USE WITH LANDSCAPE LIGHTING SYSTEMS ONLY THIS DEVICE IS ACCEPTED AS A COMPONENT OF A LANDSCAPE LIGHTING SYSTEM WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY CSA OR LOCAL INSPECTION AUTHORITIES HAVING JURISDICTION DO NOT CONNECT TWO OR MORE POWER SUPPLIES IN PARALLEL w w w . v o l t l i g h t i n g . c o m

- 2 -

Important: Please Read Before Installation

DO NOT MOUNT POWER SUPPLY OR LUMINAIRES WITHIN 3 METERS OF WATER. Specific instructions for mounting, proper wiring, grounding, and servicing. Type and minimum length of flexible cord or cable for connection to each secondary output circuit of the power supply. The supply circuit for the landscape lighting system shall be protected by a Class A type ground fault circuit interrupter, unless it is provided with the landscape lighting system. A cord-connect landscape lighting system shall not be used with an extension cord. FCC WARNING:

Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

1. this device may not cause harmful interference, and 2. this device must accept any interference received, including interference that may cause undesired operation. [email protected] 813.978.3700

- 3 -

VOLT Dock Light Controller Package Contents A. (1) Dock Light Controller B. (1) IR Remote Controller Product Dimensions C. (4) Wall Anchors D. (4) Screws 3.2 10.4 16.64 15

- 4 -

INSTALLATION INSTRUCTIONSwww.voltlighting.com 1 Install Dock Light Controller Wall Anchor Keyhole Hole Screw Screw Mark 2 1 Dock Light Controller Wall Anchor 5 1/4 3 4 Dock Light Controller Dock Light Controller Hole Screw Dock Light Controller Mark U-shaped Hole Screw 8 Dock Light Controller 9 6 7 Dock Light Controller Screw Wall Anchor Dock Light Controller 1. Place the dock light controller onto your desired location and mark two points on the wall surface from keyholes on the top of the dock light controller. 2. Drill 1/4 holes from marks and insert wall anchors into the drilled holes completely. Thread screws into wall anchors and leave approximate 1/4 length out of wall anchors. 3. Hang the keyholes on the dock light controller onto the two screws. 4. Mark two points on the wall surface from U-shaped holes on the bottom of the dock light controller. 5. Remove the dock light controller. 6. Drill 1/4 holes from marks and insert wall anchors into the drilled holes completely. [email protected] 813.978.3700

- 5 -

VOLT Dock Light Controller 1 Install Dock Light Controller (Continued) 7. Place dock light controller back onto the screws. 8. Pass the rest two screws through U-shaped holes on the bottom of the dock light controller and thread them into wall anchors. Hand tighten until snug. 9. Hand tighten the screws on the top of the dock light controller until snug. 2 Open the Door 2H 4H 6H 8H AUTO ON SET Open the door of the dock light controller. Door Dock Light Controller 3 Install Fixture Body Terminal Block Lever White Wire 1. Pass the fixture wire through the plug into the dock light controller. Strip leads of supply wires. Plug 2. Open the levers on the terminal blocks. 3. Identify the wire polarity:

white wire is positive; black wire is negative. 4. Insert white positive wires into one terminal block; insert black negative wires into another terminal block. 5. Push levers down to secure the wires. Black Wire Dock Light Controller Fixture Wire

- 6 -

INSTALLATION INSTRUCTIONSwww.voltlighting.com 4 Close the Door 2H 4H 6H 8H AUTO ON SET Dock Light Controller Fixture Wire Door 5 Connect to Wall Outlet Wall Outlet Plug from Dock Light Controller Controller Functions Close the door of the dock light controller. Insert the plug from dock light controller to wall outlet. ON AUTO 2H 4H 6H 8H SET 1. Select a controller mode using the SET button on controller. The SET button will scroll through contoller modes according to the following sequences:

ON--->AUTO--->2Hrs--->4Hrs--->6Hrs--->8Hrs--->OFF--->...... 2. The selected controller mode will be saved and remembered for future when power on and power off. When the controller is shutdown [email protected] 813.978.3700

- 7 -

VOLT Dock Light Controller Controller Functions (Continued) by pressing remote OFF, pressing ON again to return to the working mode before OFF. If current is AUTO mode, shutdown the controller by pressing OFF, and pressing ON again,it is AUTO mode. 3. In ON mode, the lights will always be on. 4. In AUTO mode, the lights will be on at dusk and off at dawn that realized by the function of the photocell part. 5. In 2Hrs/4Hrs/6Hrs/8Hrs mode, the controller will be controlled by ambient light. When the ambient light drops to 15 LUX and last for 20 seconds, the controller will power on for specific hours. After the ambient light reaches 60 LUX and last for 60 seconds, the controller will power off and it cycles every day. 6. When all lights on the controller is OFF, the power is interrupted. Code Switch Configuration 8 S 7 S 6 S 5 S 4 S 3 S 2 S 1 S ON AUTO 2H 4H 6H 8H SET 0 Press Up 1 Press Down 1. S1-S3 are for network address setting, address range: 000-111; the default address is 000 (switches keep up status). Address setting rules:

Single controller: Do not care about address settings. Multiple controllers form as a network segments: please set same address (S1-S3) for the controller that need synchronization. The

- 8 -

INSTALLATION INSTRUCTIONSwww.voltlighting.com Code Switch Configuration (Continued) first three switch set same status(press up or press down). Multiple controllers form as different network segments: if controllers require synchronization, set the same address for those controllers, and the first three switches (S1-S3) should be set to the same (up or down); if If controllers do not require synchronization, set different address, and the first three switches should be set to different status(up and down) (S1-S3). 2. S4 is Primary and secondary settings. When S4 is pressed up, this controller is primary control- start function of sending synchronization signal; Default is (UP) primary. When S4 is pressed down,this controller is secondary control, No sync signal sending function. Single controller: The S4 defaults to up, which is the primary. Multiple controllers form the same network segment : the S4 bit of the switch of only one controller is primary (press up), and the S4 of other controllers is secondary (down). Multiple controllers form different network segment: refer to above (Multiple controllers form the same network segment ). 3. S5-S8: Reserved. 4. Hardware/software configuration of primary between multiple controllers. Hardware primary is the controller whose the S4 of the switch is pressed up. Hardware secondary is the controller whose the S4 of the switch is pressed down. When the hardware primary is disconnected in the network, hardware secondary will start software primary function after 30S to ensure that there is a synchronization signal. After the hardware primary returns to normal, the software primary function of the secondary will turn off. When there are multiple secondary controls in the network, the software primary function is enabled through competition to ensure that there is a synchronization signal in the network. 5. Day and night synchronization between multiple controllers When powered on, based on the current state, synchronize other secondary in the network through the primary. During operation: Refer to the change of last actived control. The last changed control is offline: After offline for 30 seconds, it will return to the current state of controls. If there are multiple controllers, it will be generated through competition. Note: The effective distance between multiple controllers can be greater than 15m in an open area. [email protected] 813.978.3700

- 9 -

VOLT Dock Light Controller IR Remote An IR Remote is for this fixture. The IR remote requires two AAA batteries. 1 Remove the Battery compartment Cover 2 1 Tab 3 Cover Press the tab and rotate the battery compartment cover to remove it from the IR Remote. IR Remote Backing 2 Install Two AAA Batteries AAA Battery Battery Compartment Place two AAA batteries into the battery compartment properly.

IR Remote Backing 3 Install the Battery compartment Cover 2 Tab Cover 1 Place the battery compartment cover back onto the IR Remote. IR Remote Backing

- 10 -

INSTALLATION INSTRUCTIONSwww.voltlighting.com 4 IR Remote Functions 3 2 OFF ON R G W B FLASH STROBE FADE SMOOTH 1 4 5 6 7 8 1. On 2. Off 3. Brightness Control 4. 16 color selections 5. Flash: 7 color flash (R-G-B-RG-

GB-BR-RGB) with two modes

(Press FLASH once: It is mode A; Press it again: It is mode B. ) Mode A and mode B can switch alternately. Mode 1: 7 colors flash in sequence: R-G-B-RG-GB-

BR-RGB. Each color flash for 260ms per cycle, then switch to next color automatically, and follow above flash mode continouslly and automatically. Mode 2: 7 color flash in sequence in fade mode: R-G-B-RG-GB-BR-

RGB. When each color is FALSH, the brightness fade in and fade out for 2000ms, and then enters the FLASH to next color. One cycle(flash from R-G-B-RG-GB-BR-RGB) finished, then follow above flash mode continouslly and automatically. 6. Strobe: Flash with two modes: mode A & mode B. Press STROBE once, it is mode A, press it again, its mode B. Press any static color button, then press STROBE again, it will return to mode A. Mode A: Press any static color button, then press STROBE, current static color will flash continuously- flash for 260ms and then off for 260ms,then falsh again;

Mode B: RGB flash continuously - flash for 260ms and then off for 260ms,then falsh again;

7. Fade: Flash with two modes: mode A & mode B. Press FADE once, it is mode A, press it again, its mode B. Press any static color button, then press FADE again, it will return to mode A. Mode A: Press any static color button, then press FADE, current static color flash and the brightness fade in and fade out for 2100ms, then keep following this FLASH mode continouslly. Mode B: RGB flash and the brightness fade in and fade out for 2100ms, and then keep following this FLASH mode continouslly. [email protected] 813.978.3700

- 11 -

IR Remote Functions (Continued) 8. Smooth: 3 color (R-G-B) with two modes (Press SMOOTH once: It is mode A; Press it again: It is mode B. ) Mode A and mode B can switch alternately. Mode A: 3 colors flash in sequence, order: R-G-B. Each color flash for 260ms then switch to next color automatically, and following above flash mode continouslly and automatically. Mode B: The 3 color flash in fade mode, When each color is flash, the brightness fade in and fade out for 2100ms, and then enters the flash to next color. One cycle (flash from R-G-B) finished, then following above flash mode continouslly and automatically.

- 12 -

INSTALLATION INSTRUCTIONSwww.voltlighting.com

 

1 Users Manual pdf 951.79 KiB October 26 2023

 

 

n/a

 

 

1 Internal Photos pdf 1.41 MiB October 26 2023

 

 

n/a

 

 

1 External Photos pdf 375.42 KiB October 26 2023

 

ly. Intertek 5024408 LLW Enterprise, LLC CONFORMS TO UL STD.1838 CERTIFIED TO CSA STD. C22.2 No. 250.7|

S MODEL: VTR-250DC-SS INPUT: 120VAC,60Hz,2.86A OUTPUT: 24VDC, Max 250W, 13.34A FCCID: 2AI4G-TR-250DC-SS Size 55x25mm

 

1 ID Label/Location Info pdf 129.58 KiB October 26 2023

 

Attention: Application Examiner LLW Enterprise, LLC Re: Covered List, located at https://www.fcc.gov/supplychain/coveredlist and 47 CFR parts 2.903 and 2.911(d)(5)(ii) of the FCC rules Applicant: LLW Enterprise, LLC FCC ID: 2AI4G-TR-250DC-SS To whom it may concern, LLW Enterprise, LLC (Applicant) certifies that the equipment for which authorization is sought is not covered equipment prohibited from receiving an equipment authorization pursuant to 47 CFR part 2.903 of the FCC rules and does not originate directly or indirectly from any company named on the covered list located in the link above or any subsidiary or affiliate thereof. Applicant further certifies that, as of the date of the filing of the application, the Applicant is not identified on the Covered List as an entity producing covered equipment and is not a subsidiary or affiliate of any such entity pursuant to 47 CFR part 1.50002 and required by 47 CFR part 2.911(d)(5)(ii) of the FCC rules. I HEREBY CERTIFY THAT I am authorized to make the representations above on behalf of the Applicant and agree to immediately notify Intertek if there is any change in the status identified above. ______________________________ Jana Prough VP of Administration & Accounting LLW Enterprise, LLC 2023-3-22 Form: RFT-AMER-TCB-OP-19n Date: 1/25/2023 Revision: 1 Page 1 of 1

 

1 Attestation Statements pdf 75.72 KiB October 26 2023

 

LLW Enterprise, LLC 2022-12-06 Attention: Application Examiner RE:

Request for Confidentiality Applicant: LLW Enterprise, LLC FCC ID: 2AI4G-TR-250DC-SS To Whom It May Concern:

Permanent Confidentiality [Complete this section if permanent confidentiality is requested]

Request is hereby submitted by LLW Enterprise, LLC to withhold permanently from public review certain portions of the application for equipment certification for the referenced FCC identifiers. This request for confidentiality is made pursuant to 47 CFR 0.457(d) and 0.459 of the FCC Rules. In particular, the following sections of the application are to be kept permanently confidential:

[Select one or more of items below, as appropriate]

Schematics Detailed Block Diagrams Detailed Operational/Functional Description Rationale for request for confidentiality:

LLW Enterprise, LLC has invested considerable time and materials in research and development to produce the referenced product. [Permanent confidentiality: Disclosure of the permanently confidential portions of this application to competitors would not only give them significant competitive advantages in developing similar products, but would also disclose successful implementation of unpublished, leading edge technology developed by us.]

If you have questions or need further information, please contact the undersigned. Sincerely, Jana Prough VP of Administration & Accounting LLW Enterprise, LLC 1(1)

 

1 Cover Letter(s) pdf 28.51 KiB October 26 2023

 

LLW Enterprise, LLC 2023-10-20 Federal Communications Commission 445 12th Street SW Washington, DC 20554 Subject:

Limited Agency Agreement LLW Enterprise, LLC FCC ID: 2AI4G-TR-250DC-SS To Whom It May Concern:

We, LLW Enterprise, LLC, hereby authorized Intertek Testing Services Shenzhen Ltd. Guangzhou Branch to act as our Agent for the purpose of preparing application for 2AI4G-TR-

250DC-SS under all applicable parts of the FCC rules and regulations. The effective date of this limited agency agreement is 2023-10-20 The Limited Agency Agreement expires on 2024-04-20, unless sooner terminated or extended by written notice to Intertek Testing Services Shenzhen Ltd. Guangzhou Branch and the Federal Communications Commission. This is to advise that we are in full compliance with the Anti-Drug Abuse Act. The applicant is not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 U.S.C. 862, and no party to the application is subject to a denial of federal benefits pursuant to that section. If you have any questions or comments, please do not hesitate to contact me. Sincerely, Jana Prough VP of Administration & Accounting

 

1 Cover Letter(s) pdf 19.14 KiB October 26 2023

 

 

n/a

 

 

1 RF Exposure Info pdf 192.78 KiB October 26 2023

 

 

n/a

 

 

1 Test Report pdf 85.76 KiB October 26 2023

 

 

n/a

 

 

1 Test Setup Photos pdf 290.37 KiB October 26 2023
frequency equipment class purpose
1 2023-10-26 433.92 ~ 433.92 DSC - Part 15 Security/Remote Control Transmitter Original Equipment

Application Forms

app s Applicant Information
1 Effective 2023-10-26
1 Applicant's complete, legal business name LLW Enterprise LLC
1 FCC Registration Number (FRN) 0025728213
1 Physical Address 15486 N Nebraska Ave
1 Lutz, Florida 33549
1 United States
app s TCB Information
1 TCB Application Email Address T******@intertek.com
1 TCB Scope A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
app s FCC ID
1 Grantee Code 2AI4G
1 Equipment Product Code TR-250DC-SS
app s Person at the applicant's address to receive grant or for contact
1 Name J****** M****** P********
1 Title Controller
1 Telephone Number 81397********
1 Fax Number 240-5********
1 E-mail j******@voltlighting.com
app s Technical Contact
1 Firm Name Intertek Testing Services Shenzhen Ltd.,Guangzhou
1 Name R**** L********
1 Physical Address lock E, No.7-2 Guang Dong Software Science Park, C
1 Guangzhou, Guangdong, 510663
1 China
1 Telephone Number +86 2********
1 E-mail R******@intertek.com
app s Non Technical Contact
1 Firm Name Intertek Testing Services Shenzhen Ltd.,Guangzhou
1 Name R******** L****
1 Physical Address lock E, No.7-2 Guang Dong Software Science Park, C
1 Guangzhou, Guangdong, 510663
1 China
1 Telephone Number +8620********
1 E-mail R******@intertek.com
app s Confidentiality (long or short term)
1 Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?:Yes
1 Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?:No
if no date is supplied, the release date will be set to 45 calendar days past the date of grant.
app s Cognitive Radio & Software Defined Radio, Class, etc
1 Is this application for software defined/cognitive radio authorization?No
1 Equipment ClassDSC - Part 15 Security/Remote Control Transmitter
1 Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant)Underwater dock light controller
1 Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application?No
1 Modular Equipment TypeDoes not apply
1 Purpose / Application is forOriginal Equipment
1 Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization?No
1 Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization?No
1 Is there an equipment authorization waiver associated with this application?No
1 If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded?No
app s Test Firm Name and Contact Information
1 Firm Name Intertek Testing Services Shenzhen LTD., Guangzhou
1 Name E****** H****
1 Telephone Number +86 2********
1 E-mail E******@intertek.com
Equipment Specifications
Line Rule Parts Grant Notes Lower Frequency Upper Frequency Power Output Tolerance Emission Designator Microprocessor Number
1 1 15.231 433.92000000 433.92000000

 

some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details

 

  This product uses the FCC Data API but is not endorsed or certified by the FCC