all | frequencies |
|
|
exhibits | applications |
---|---|---|---|---|---|
manuals |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User Manual part 1 | Users Manual | 5.59 MiB | September 08 2016 / October 08 2016 | |||
1 |
|
User Manual part 2 | Users Manual | 5.35 MiB | September 08 2016 / October 08 2016 | |||
1 | Cover Letter(s) | September 08 2016 / October 08 2016 | ||||||
1 | Cover Letter(s) | September 08 2016 / October 08 2016 | ||||||
1 | External Photos | September 08 2016 / October 08 2016 | ||||||
1 | Internal Photos | September 08 2016 / October 08 2016 | ||||||
1 | ID Label/Location Info | September 08 2016 / October 08 2016 | ||||||
1 | Cover Letter(s) | September 08 2016 / October 08 2016 | ||||||
1 | Test Setup Photos | September 08 2016 / October 08 2016 | ||||||
1 | Test Report | September 08 2016 / October 08 2016 |
1 | User Manual part 1 | Users Manual | 5.59 MiB | September 08 2016 / October 08 2016 |
This device complies with Part 15 of the FCC Rules and with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/ TV technician for help.
1 | User Manual part 2 | Users Manual | 5.35 MiB | September 08 2016 / October 08 2016 |
OPERATING INSTRUCTIONS FOR OEM USE ONLY 4-SYMBOL Child Proof Time Signal Indicator Countdown Timer Battery Status Fahrenheit or Celsius
LTE! VASES. Temperature Figure 26: 4-symbol Display SETTING FAHRENHEIT or CELSIUS CHILD PROOF To change between C and F, press and buttons simultaneously. NOTE: Choosing F results in a 12 hour clock. Choosing C results in a 24 hour clock. SETTING the TIME
. Press @ and buttons simultane-
ously. Day flashes. Press @) or W) button to select a num-
ber to correspond with the day of the week (e.g. !=Monday, =Tuesday, J=Wednesday, 4=Thursday, 5=Fri-
day, 6= Saturday, 1= Sunday). Press (@) and () buttons simultane-
ously. Hour flashes. To select hour press @ or button. Press @ and v) buttons simultane-
ously. Minutes flash. 6. To select minutes press @) or ) but-
ton. 7. To confirm press @ and () buttons simultaneously or wait. 2016 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved. ON:
To activate press ) and () buttons simultaneously. displayed and the handset is rendered inoperable, except for the off function. OFF:
To deactivate press ) and () buttons simultaneously. disappears. MANUAL MODE (HANDSET) BEFORE OPERATING 1. Make sure MANUAL knob on the GV60 vaive is in the ON, full counterclockwise <2 position. 2. Place the ON/OFF switch (if equipped) in the I (ON) position. TO TURN ON FIRE When pilot ignition is confirmed, motor turns automatically to maximum flame height. 17/33 OPERATING INSTRUCTIONS FOR OEM USE ONLY Handset One-Button Operation
(Default Setting)
* Press button until two short beeps and a blinking series of lines confirms the start sequence has begun; release button. Main gas flows once pilot ignition is confirmed.
= Handset automatically goes into Man-
ual Mode after main burner ignition. Change from one-button to two-button ignition operation by pressing and holding button for 10 sec. immediately after installing batteries. ON is displayed and 1 is flashing. When change is complete 1 will change to 2. Handset Two-Button Operation
= Press and @ button simultaneously until two short beeps and a blinking series of lines confirms the start se-
quence has begun; release buttons.
= Main gas flows once pilot ignition is confirmed.
= Handset automatically goes into Man-
ual Mode after main burner ignition. NOTICE Change from two-button to one-button ignition operation by pressing and holding button for 10 sec. immediately after installing batteries. ON is displayed and 2 is flashing. When change is complete 2 will change to 1. PAAR If the pilot does not stay lit after several tries, turn the main valve knob to OFF and follow the instructions TO TURN OFF GAS TO APPLIANCE (page 33). STANDBY MODE (PILOT FLAME) Handset
= Press and hold () button to set appliance to pilot flame. TO TURN OFF FIRE Handset Press ) button to turn off. NOTE: There is a 5 sec delay before the next ignition is possible. 18/33 FLAME HEIGHT ADJUSTMENT Handset
*To increase flame height press and hold @) button.
= To decrease flame height or to set ap-
pliance to pilot flame, press and hold
&) button. DESIGNATED LOW FIRE and HIGH FIRE NOTE: Backlight must be on for high fire and low fire double-click operation.
* To go to low fire, double-click &) but-
ton. LOis displayed. NOTE: Flame goes to high fire first be-
fore going to low fire.
= To go to high fire, double-click @ but-
ton. H tis displayed. If the appliance will not operate, follow the instructions TO TURN OFF GAS TO APPLIANCE (page 33). COUNTDOWN TIMER ON/SETTING:
1. Press and hold () button until % dis-
played, and hour flashes. 2. To select hour press @ or button. 3. To confirm press (&) button. Minutes flash. 4. To select minutes press BorW button. 5. To confirm press (S) button or wait. OFF:
Press (8) button, % and countdown time disappear. NOTE: At end of countdown time period, the fire turns off. The Countdown Timer only works in Manual, Thermostatic, and Eco Modes. Maximum countdown time is 9 hours and 50 minutes. 2016 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved. OPERATING INSTRUCTIONS FOR OEM USE ONLY 6-SYMBOL Child Proof Time Signal Indicator Thermostatic Mode 5 ) Battery Status 44) 4074 AM :
_ Countdown Timer > wy Oo NE, SG -
GD) i Fahrenheit or Celsius
[Ojev LS <a Program Mode , OFF
(12 VaumS Vom
Temperature Figure 27: 6-symbol Display SETTING FAHRENHEIT or CELSIUS CHILD PROOF To change between C and F, press ) and buttons simultaneously. NOTE: Choosing F results in a 12 hour clock. Choosing C results in a 24 hour clock. SETTING the TIME
. Press @ and ) buttons simultane-
ously. Day flashes. Press @) or W) button to select a num-
ber to correspond with the day of the week (e.g. '=Monday, =Tuesday, 3=Wednesday, 4=Thursday, 5=Fri-
day, = Saturday, 1= Sunday). Press (A) and buttons simultane-
ously. Hour flashes. To select hour press @ or ) button. Press @) and Wy) buttons simultane-
ously. Minutes flash. 6. To select minutes press @ or but-
ton. 7. To confirm press @) and ) buttons simultaneously or wait. 2016 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved. ON:
To activate press and ) buttons simultaneously. Sy displayed and the handset is rendered inoperable, except for the off function. OFF:
To deactivate press and ) buttons simultaneously. disappears. MANUAL MODE (HANDSET) BEFORE OPERATING 1. Make sure MANUAL knob on the GV60 valve is in the ON, full counterclockwise <2 position. 2. Place the ON/OFF switch (if equipped) in the I (ON) position. TO TURN ON FIRE When pilot ignition is confirmed, motor turns automatically to maximum flame height. 19/33 OPERATING INSTRUCTIONS FOR OEM USE ONLY Handset One-Button Operation
(Default Setting)
* Press ) button until two short beeps and a blinking series of lines confirms the start sequence has begun; release button. Main gas flows once pilot ignition is confirmed.
= Handset automatically goes into Man-
ual Mode after main burner ignition. Change from one-button to two-button ignition operation by pressing and holding button for 10 sec. immediately after installing batteries. ON is displayed and 1 is flashing. When change is complete 1 will change to 2. Handset Two-Button Operation
* Press ) and @) button simultaneously until two short beeps and a blinking series of lines confirms the start se-
quence has begun; release buttons. Main gas flows once pilot ignition is confirmed.
= Handset automatically goes into Man-
ual Mode after main burner ignition. uleiles Change from two-button to one-button ignition operation by pressing and holding button for 10 sec. immediately after installing batteries. ON is displayed and 2 is flashing. When change is complete 2 will change to 1. PWR) If the pilot does not stay lit after several tries, turn the main valve knob to OFF and follow the instructions TO TURN OFF GAS TO APPLIANCE (page 33). STANDBY MODE (PILOT FLAME) Handset
* Press and hold () button to set appliance to pilot flame. TO TURN OFF FIRE Handset
* Press ) button to turn off. NOTE: There is a 5 sec delay before the next ignition is possible. 20/33 FLAME HEIGHT ADJUSTMENT Handset To increase flame height press and hold @ button.
* To decrease flame height or to set ap-
pliance to pilot flame, press and hold
) button. DESIGNATED LOW FIRE and HIGH FIRE NOTE: Backlight must be on for high fire and low fire double-click operation.
* To go to low fire, double-click (V) but-
ton. LB is displayed. NOTE: Flame goes to high fire first be-
fore going to low fire.
* To go to high fire, double-click (A) but-
ton. H tis displayed. If the appliance will not operate, follow the instructions TO TURN OFF GAS TO APPLIANCE (page 33). COUNTDOWN TIMER ON/SETTING:
1. Press and hold (@) button until dis-
played, and hour flashes. 2. To select hour press ) or () button. 3. To confirm press (@) button. Minutes flash. 4. To select minutes press @) or () button. 5. To confirm press button or wait. OFF:
Press @ button, & and countdown time disappear. NOTE: At end of countdown time period, the fire turns off. The Countdown Timer only works in Manuai, Thermostatic, and Eco Modes. Maximum countdown time is 9 hours and 50 minutes. 2016 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved. OPERATING INSTRUCTIONS FOR OEM USE ONLY MODES of OPERATION J Thermostatic Mode The room temperature is measured and compared to the set temperature. The flame height is then automatically ad-
justed to achieve the set temperature. Program Mode Programs 1 and 2, each can be pro-
grammed to go on and off at specific times at a set temperature. THERMOSTATIC MODE 2016 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved. ON:
Press (1) button. | displayed, preset tem-
perature displayed briefly, and then room temperature displayed. OFF:
1. Press 0) button. 2. Press (A) or () button to enter Manual Mode. 3. Press @ button to enter Program Mode. SETTING:
1. Press (J) button and hold until | dis-
played, temperature flashes. 2. To adjust set temperature press (@) or button. 3. To confirm press (1) button or wait. PROGRAM MODE ON:
Press @ button. @), 4 or 2, ON or OFF displayed. OFF:
1. Press @) or @) or () button to enter Manual Mode. 2. Press (J) button to enter Thermostatic Mode. NOTE: The set temperature for Thermostatic Mode is the tem-
perature for the on time in Program Mode. Changing the Thermostatic Mode set temperature also changes the on time temperature in Program Mode. Default settings:
ON TIME (Thermostatic) TEMPERATURE: 21C (70F) OFF TIME TEMPERATURE: ~" (pilot flame only) TEMPERATURE SETTING:
1. Press button and hold until @) fla-
shes. ON and set temperature (setting in Thermostatic Mode) displayed. 2. To continue press @ button or wait.
@), OFF displayed, temperature flash-
es. 3. Select off temperature by pressing the @) or ) button. 4. To confirm press button. NOTE: The on (Thermostatic) and off set temperatures are the same for each day. DAY SETTING:
5. ALL flashes. Press A) or () button to choose between Ait, SASY, t, 23,4, 5,6,7%. 6. To confirm press @ button. 21/33 OPERATING INSTRUCTIONS FOR OEM USE ONLY it selected 5 NOTE:
NOTE:
NOTE:
ON TIME SETTING (PROGRAM 1):
7.@), 4, ONdisplayed, ALL is displayed shortly, and hour flashes. 8. To select hour press @) or () button. _., 9. To confirm press button. @), 4, ON displayed, ALL displayed shortly,
@) and minutes flash. 9) 10. To select minutes press (A) or () but-
y) ton. 11. To confirm press @) button. OFF TIME SETTING (PROGRAM 1):
12. @), 1, OFF displayed, ALL is displayed shortly, and hour flashes. 13. To select hour, press ) or () button. 14.To confirm press button. @), 4, OFF displayed, Ait displayed short-
ly, and minutes flash. 15. To select minutes press (A) or (V) but-
ton. 16. To confirm press @ button. Either continue to PROGRAM 2 and set on and off times or stop programming at this point, and PROGRAM 2 re-
mains deactivated. PROGRAM 1 and 2 use the same on (Thermostatic) and off temperatures for ALL, SASU and Daily Timer (i, 2, 3, 4, S, 6, 1). Once a new on (Thermostatic) and/or off tem-
perature has been set, that temperature becomes the new default setting. If Aut, SASU or Daily Timer are programmed for PRO-
GRAM 1 and PROGRAM 2 on and off times, these be-
come the new default times. The batteries must be re-
moved to clear the PROGRAM 1 and PROGRAM 2 on and off times and temperatures. SRSU or Daily Timer (i, 2, 3,4, 5, 6, 1) selected wpe
* Set on time and off time using same procedure as Ail se-
lected (above).
= SRSU: Set on time and off time for both Saturday and Sunday.
= Daily Timer: Unique on and off times may be set for a single day of the week, for multiple days of the week, or for every day of the week. Wait to finish setting. 22/33 2016 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved. OPERATING INSTRUCTIONS FOR OEM USE ONLY 2016 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved. 8-SYMBOL Child Proof Countdown Timer Program Mode Time Signal Indicator Thermostatic Mode Battery Status
ay I < Fahrenheit or Celsius
> s_ 12 TERS VALENS 4 Ag. * Eco Mode Temperature Auxiliary Feature Figure 28: 8-symbo! Display SETTING FAHRENHEIT or CELSIUS CHILD PROOF SETTING the TIME To change between C and F, press ) and buttons simultaneously. NOTE: Choosing F results in a 12 hour
. Press @ and ) buttons simultane-
ously. Day flashes. BEFORE OPERATING
. Press @) or ) button to select a num- 4. Make sure MANUAL knob on the GV60 valve is in the ON, ber to correspond with the day of the full counterclockwise <4 position. week (e.g. i=Monday, =Tuesday, 2. Place the ON/OFF switch (if equipped) in the | (ON) position. 3=Wednesday, 4=Thursday, 5=Fri-
day, 6= Saturday, 1= Sunday). Press (A) and () buttons simultane-
ously. Hour flashes. TO TURN ON FIRE _ To select hour press @) or () button. Press @ and buttons simultane-
ON:
To activate press ) and ) buttons simultaneously. C5 displayed and the handset is rendered inoperable, except clock. Choosing C results in a for the off function. 24 hour clock. OFF:
To deactivate press ) and () buttons simultaneously. disappears. MANUAL MODE (HANDSET) ously. Minutes flash. When pilot ignition is confirmed, motor turns automatically to 6. To select minutes press (A) or W) but- maximum flame height. ton. 7. To confirm press @) and () buttons simultaneously or wait. 23/33 OPERATING INSTRUCTIONS FOR OEM USE ONLY Handset One-Button Operation
(Default Setting)
* Press ) button until two short beeps and a blinking series of lines confirms the start sequence has begun; release button.
= Main gas flows once pilot ignition is confirmed. Handset automatically goes into Man-
ual Mode after main burner ignition. Change from one-button to two-button ignition operation by pressing and holding button for 10 sec. immediately after installing batteries. ON is displayed and 1 is flashing. When change is complete 1 will change to 2. Handset Two-Button Operation Press ) and @) button simultaneously until two short beeps and a blinking series of lines confirms the start se-
quence has begun; release buttons.
* Main gas flows once pilot ignition is confirmed. Handset automatically goes into Man-
ual Mode after main burner ignition. Change from two-button to one-button ignition operation by pressing and holding button for 10 sec. immediately after installing batteries. ON is displayed and 2 is flashing. When change is complete 2 will change to 1. PWARNING) If the pilot does not stay lit after several tries, turn the main valve knob to OFF and follow the instructions TO TURN OFF GAS TO APPLIANCE (page 33). STANDBY MODE (PILOT FLAME) Handset
= Press and hold button to set appliance to pilot flame. TO TURN OFF FIRE Handset
* Press ) button to turn OFF. NOTE: There is a 5 sec delay before the next ignition is possible. 24/33 FLAME HEIGHT ADJUSTMENT Handset To increase flame height press and hold @ button.
= To decrease flame height or to set ap-
pliance to pilot flame, press and hold
) button. DESIGNATED LOW FIRE and HIGH FIRE NOTE: Backlight must be on for high fire and low fire double-click operation.
* To go to low fire, double-click (V) but-
ton. LO is displayed. NOTE: Flame goes to high fire first be-
fore going to low fire.
* To go to high fire, double-click (A) but-
ton.H tis displayed If the appliance will not operate, follow the instructions TO TURN OFF GAS TO APPLIANCE (page 33). COUNTDOWN TIMER ON/SETTING:
1, Press and hold (@) button until % dis-
played, and hour flashes. 2. To select hour press @) or W) button. 3. To confirm press (&) button. Minutes flash. 4. To select minutes press @) or ) button. 5. To confirm press button or wait. OFF:
Press @ button, & and countdown time disappear. NOTE: At end of countdown time period, the fire turns off. The Countdown Timer only works in Manual, Thermostatic, and Eco Modes. Maximum countdown time is 9 hours and 50 minutes. 2016 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved. OPERATING INSTRUCTIONS FOR OEM USE ONLY 2016 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved, MODES of OPERATION
| Thermostatic Mode The room temperature is measured and compared to the set temperature. The flame height is then automatically ad-
justed to achieve the set temperature. Program Mode PROGRAMS 1 and 2, each can be pro-
grammed to go on and off at specific times at a set temperature. th Eco Mode Flame height modulates between high and low. If the room temperature is low-
er than the set temperature, the flame height stays on high for a longer period of time. If the room temperature is high-
er than the set temperature, the flame height stays on low for a longer period of time. One cycle lasts approx. 20min. THERMOSTATIC MODE ON:
Press (J) button. J displayed, preset tem-
perature displayed briefly, and then room temperature displayed. OFF:
1. Press (1) button. 2. Press @ or ) button to enter Manual Mode. 3. Press button to enter Program Mode. 4. Press @) button to enter Eco Mode. SETTING:
1. Press (J) button and hold until J dis-
played, temperature flashes. 2. To adjust set temperature press @ or button. 3. To confirm press (J) button or wait. PROGRAM MODE ON:
Press @ button. @), 4 or 2, ON or OFF displayed. OFE:
1. Press or () or W) button to enter Manual Mode. 2. Press (J) button to enter Thermostatic Mode. NOTE: The set temperature for Thermostatic Mode is the tem-
perature for the on time in Program Mode. Changing the Thermostatic Mode set temperature also changes the on time temperature in Program Mode. Default settings:
ON TIME (Thermostatic) TEMPERATURE: 21C (70F) OFF TIME TEMPERATURE: ~- (pilot flame only) TEMPERATURE SETTING:
1. Press @ button and hold until flashes. ON and set temperature (set-
ting in Thermostatic Mode) displayed. 2. To continue press @ button or wait.
@), OFF displayed, temperature flash-
es. 3. Select off temperature by pressing the @) or () button. 4. To confirm press @ button. NOTE: The on (Thermostatic) and off set temperatures are the same for each day. DAY SETTING:
5. RLL flashes. Press @) or V) button to choose between ALL, SASY, f, 2, J, 4, 56,2. 6. To confirm press @ button. 25/33 OPERATING INSTRUCTIONS FOR OEM USE ONLY it selected NOTE:
NOTE:
NOTE:
ON TIME SETTING (PROGRAM 1):
i oo 4, ON displayed, Rit is displayed shortly, and hour flashes. 8. To select hour press @ or W) button. 9. To confirm press button. @), 4, ON displayed, ALL displayed shortly, and minutes flash. 10. To select minutes press @ or (0) but-
ton. 11. To confirm press button. OFF TIME SETTING (PROGRAM 1):
12. @), 1, OFF displayed, ALL is displayed shortly, and hour flashes. 13. To select hour, press @ or w) button. 14.To confirm press @) button. @), 4, OFF displayed, Rit displayed short-
ly, and minutes flash. 15. To select minutes press (A) or () but-
ton. 16. To confirm press button. Either continue to PROGRAM 2 and set on and off times or stop programming at this point, and PROGRAM 2 re-
mains deactivated. PROGRAM 1 and 2 use the same on (Thermostatic) and off temperatures for ALL, SASU and Daily Timer (, 2, 3, 4, 5, 6, 1). Once a new on (Thermostatic) and/or off tempera-
ture has been set, that temperature becomes the new default setting If ALL, SASU or Daily Timer are programmed for PRO-
GRAM 1 and PROGRAM 2 on and off times, these be-
come the new default times. The batteries must be re-
moved to clear the PROGRAM 1 and PROGRAM 2 on and off times and temperatures. SASU or Daily Timer (, 2, 3,4, 5, 6, %) selected Set on time and off time using same procedure as ALL se-
lected (above).
= SRSU: Set on time and off time for both Saturday and Sunday.
* Daily Timer: Unique on and off times may be set for a single day of the week, for multiple days of the week, or for every day of the week.
* Wait to finish setting. 26/33 AUXILIARY FEATURE Upon ignition burner 1 is on and burner 2 is in the last setting. ON:
To switch a burner on, press the @) but-
ton. + displayed. OFF:
To switch the burner OFF, press the button. + disappears. NOTE: The latching solenoid valve cannot operate manually. If the receiver battery runs down it will remain in the last operating position. ECO MODE ON:
Press @ button to enter Eco Mode. 4a displayed. OFF:
Press @) button. Aa disappears. 2016 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved OPERATING INSTRUCTIONS FOR OEMUSE ONLY 2016 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved. 10-SYMBOL Child Proof Time Signal Indicator Thermostatic Mode 1 Battery Status eM _ ONAN PM. 3 Sac Countdown Timer TE, Oo vey} Fan r BEES r < - Fahrenheit or Celsius ON =a aa Light Program Mode 4 Yams Vamos Temperature Auxiliary Feature Figure 29: 10-symbol Display SETTING FAHRENHEIT or CELSIUS CHILD PROOF SAn ai) PU SETTING the TIME To change between C and F, press ) and buttons simultaneously. NOTE: Choosing F results in a 12 hour
. Press (@) and () buttons simultane-
ously. Day flashes. BEFORE OPERATING
. Press {@) or W) button to select a num- 1. Make sure MANUAL knob on the GV60 valve is in the ON, ber to correspond with the day of the full counterclockwise <4 position. week (e.g. i=Monday, =Tuesday, 2. Place the ON/OFF switch (if equipped) in the I (ON) position. 3=Wednesday, 4=Thursday, 5=Fri-
ON:
To activate press and a) buttons simultaneously. displayed and the handset is rendered inoperable, except clock. Choosing C results in a for the off function. 24 hour clock. OFF:
To deactivate press and () buttons simultaneously. disappears. MANUAL MODE (HANDSET) day, b= Saturday, 1= Sunday). Press () and () buttons simultane-
ously. Hour flashes. TO TURN ON FIRE
. To select hour press @) or V) button. Press (@) and () buttons simultane-
ously. Minutes flash. When pilot ignition is confirmed, motor turns automatically to 6. To select minutes press (A) or ) but- maximum flame height. ton. 7. To confirm press @ and () buttons simultaneously or wait. 27/33 OPERATING INSTRUCTIONS FOR OEM USE ONLY Handset One-Button Operation FLAME HEIGHT ADJUSTMENT
(Default Setting)
* Press ) button until two short beeps and a blinking series of lines confirms the start sequence has begun; release button.
= Main gas flows once pilot ignition is confirmed. Handset automatically goes into Man-
ual Mode after main burner ignition. Handset
*To increase flame height press and hold @) button.
= To decrease flame height or to set ap-
pliance to pilot flame, press and hold W) button. Change from one-button to two-button ignition operation by pressing and holding button for 10 sec. immediately after installing batteries. ON is displayed and 1 is flashing. When change is complete 4 will change to 2. DESIGNATED LOW FIRE and HIGH FIRE NOTE: Backlight must be on for high fire and low fire double-click operation. Handset Two-Button Operation Press ) and @) button simultaneously until two short beeps and a blinking series of lines confirms the start se-
quence has begun; release buttons.
* Main gas flows once pilot ignition is confirmed. Handset automatically goes into Man-
ual Mode after main burner ignition.
= To go to low fire, double-click ) but-
ton. LO is displayed. NOTE: Flame goes to high fire first be-
fore going to low fire.
* To go to high fire, double-click @ but-
ton. H tis displayed. Change from two-button to one-button ignition operation by pressing and holding button for 10 sec. immediately after installing batteries. ON is displayed and 2 is flashing. When change is complete 2 will change to 4. PAWARNING) If the pilot does not stay lit after several tries, turn the main valve knob to OFF and follow the instructions TURN OFF GAS TO APPLIANCE (page 33). If the appliance will not operate, follow the instructions TURN STANDBY MODE (PILOT FLAME) OFF GAS TO APPLIANCE (page 33). Handset
* Press and hold () button to set appliance to pilot flame. COUNTDOWN TIMER TO TURN OFF FIRE ON/SETTING:
1. Press and hold (&) button until dis-
played, and hour flashes. 2. To select hour press @ or ) button. 3. To confirm press ) button. Minutes flash. 4. To select minutes press @orW) button. 5. To confirm press button or wait. Handset
+ Press button to turn off. NOTE: There is a 5 sec delay before the next ignition is possible. OFF:
Press (8) button, % and countdown time disappear. NOTE: At end of countdown time period, the fire turns off. The Countdown Timer only works in Manual, Thermostatic, and Eco Modes. Maximum countdown time is 9 hours and 50 minutes. 2016 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved. 28/33 OPERATING INSTRUCTIONS FOR OEM USE ONLY 2016 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved. MODES of OPERATION
| Thermostatic Mode The room temperature is measured and compared to the set temperature. The flame height is then automatically ad-
justed to achieve the set temperature. Program Mode Programs 1 and 2, each can be pro-
grammed to go on and off at specific times at a set temperature. eM Eco Mode Flame height modulates between high and low. If the room temperature is low-
er than the set temperature, the flame height stays on high for a longer period of time. If the room temperature is high-
er than the set temperature, the flame height stays on low for a longer period of time. One cycle lasts approx. 20min. THERMOSTATIC MODE ON:
Press button. J displayed, preset tem-
perature displayed briefly, and then room temperature displayed. OFF:
1. Press d button. 2. Press (A) or () button to enter Manual Mode. 3. Press @uttn to enter Program Mode. 4. Press (4) button to enter Eco Mode. SETTING:
1. Press (1) button and hold until J dis-
played, temperature flashes. 2. To adjust set temperature press @) or
) button. 3. To confirm press (1) button or wait. PROGRAM MODE ON:
Press @ button. @), 4 or 2, ON or OFF displayed. OFF:
1. Press @ or @ or ) button to enter Manual Mode. 2. Press button to enter Thermostatic Mode. 3. Press (4) button to enter Eco Mode. NOTE: The set temperature for Thermostatic Mode is the tem-
perature for the on time in Program Mode. Changing the Thermostatic Mode set temperature also changes the on time temperature in Program Mode. Default settings:
ON TIME (Thermostatic) TEMPERATURE: 21C (70F) OFF TIME TEMPERATURE: ~ (pilot flame only) TEMPERATURE SETTING:
1. Press @) button and hold until flashes. ON and set temperature (set-
ting in Thermostatic Mode) displayed. 2. To continue press @ button or wait.
@), OFF displayed, temperature flash-
es. 3. Select off temperature by pressing the @) or () button. 4. To confirm press @ button. NOTE: The on (Thermostatic) and off set temperatures are the same for each day. DAY SETTING:
5. ALL flashes. Press ) or () button to choose between Att, SASY, t, 2, 3,4, 5,6, 7 6. To confirm press button. 29/33 OPERATING INSTRUCTIONS FOR OEM USE ONLY Lt selected NOTE:
NOTE:
NOTE:
ON TIME SETTING (PROGRAM 1):
7.@), 4, ON displayed, ALL is displayed shortly, and hour flashes. 8. To select hour press @ or v) button. 9. To confirm press @) button. @), 4, ON displayed, ALL displayed shortly, and minutes flash. 10. To select minutes press @ or but-
ton. 11. To confirm press @ button. OFF TIME SETTING (PROGRAM 1):
.@), 1, OFF displayed, ALt is displayed shortly, and hour flashes. 13. To select hour, press (A) or ) button. 14.To confirm press @ button. @), 4, OFF displayed, ALi displayed short-
ly, and minutes flash. 15. To select minutes press @ or ) but-
ton. 16. To confirm press @ button. Either continue to PROGRAM 2 and set on and off times or stop programming at this point, and PROGRAM 2 re-
mains deactivated. PROGRAM 1 and 2 use the same on (Thermostatic) and off temperatures for ALL, SASU and Daily Timer (i, 2, 3,4, 5, 6, 3). Once a new on (Thermostatic) and/or off tempera-
ture has been set, that temperature becomes the new default setting. If Rit, SASU or Daily Timer are programmed for PRO-
GRAM 1 and PROGRAM 2 on and off times, these be-
come the new default times. The batteries must be re-
moved to clear the PROGRAM 1 and PROGRAM 2 on and off times and temperatures. SRSU or Daily Timer (i, 2, 3,4, 5, 6, 1) selected
= Set on time and off time using same procedure as ALL se-
lected (above).
= SASU: Set on time and off time for both Saturday and Sunday.
= Daily Timer: Unique on and off times may be set for a single day of the week, for multiple days of the week, or for every day of the week.
* Wait to finish setting. 30/33 AUXILIARY FEATURE Upon ignition burner 1 is on and burner 2 is in the last setting. ON:
To switch a burner on, press the @ but-
ton. + displayed. OFF:
To switch the burner off, press the @
button. 4 disappears. NOTE: The latching solenoid valve cannot operate manually. If the receiver battery runs down it will remain in the last operating position. ECO MODE ON:
Press button to enter Eco Mode. Aa displayed. OFF:
Press () button. A disappears. CIRCULATING FAN OPERATION NOTE:
Circulating fan has 4 speed levels from low (1 bar) to high (4 bars). SETTING:
4.Press @) button and hold until &
flashes. 2. Press @ button to increase fan speed and button to decrease fan speed. 3. To confirm setting either press cS) but-
ton or wait (& displayed). OFF:
Press y) button until all 4 speed level bars disappear. SETTING only. If the fan was not switched off after last use, it starts automatically 4 minutes after ignition at max-
imum speed and goes to the last set level after 10 sec-
onds. The fan stops 10 minutes after the gas is OFF or at pilot. 2016 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved. OPERATING INSTRUCTIONS FOR OEM USE ONLY 2016 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved. LIGHT/ DIMMER OPERATION ON:
Press (@) button (@ displayed). Light is on at preset level. OFF:
Press @) button (@ disappears). SETTING:
1. Press @) button and hold until # flash-
es. 2. To adjust light between 20...100%
press (A) or () button. 3. To confirm setting either press but-
ton or wait (@ displayed). NOTE: The Light works independently of the Pilot flame. If you want the light on but no flame, press button. MYFIRE APP Before the App can be used, the myfire Wi-Fi Box must be wired and plugged into mains power according to myfire App setup diagram (see figure 20, page 12), and the App setup must be completed (see myfire App setup, page 15). If Thermostatic, Program or Eco Mode is activated, the corresponding icon and APP is displayed on the handset. The modes can be operated according to the descriptions on previous pages. NOTE: In Manual Mode APP is NOT displayed on the handset. 31/33 OPERATING INSTRUCTIONS FOR OEM USE ONLY TOUCHPAD/WALL SWITCH SWITCH PANEL Increase flame height A) Increase flame height ON-OFF B) ON/OFF Decrease flame height C) Decrease flame height Figure 30: Touchpad /Wall Switch To Turn ON Appliance
* Press ON-OFF button (see figure 30) until two short beeps con-
firm the start sequence has begun; release button.
* Once pilot ignition is confirmed, there is main gas flow. If the pilot does not stay lit after several tries, turn the main valve knob to OFF and follow the instructions TO TURN OFF GAS TO APPLIANCE (page 33). Figure 31: Switch Panel To Turn ON Appliance
= Press B button (see figure 31) until two short beeps confirm the start sequence has begun; release button.
* Once pilot ignition is confirmed, there is main gas flow. If the pilot does not stay lit after several tries, turn the main valve knob to OFF and follow the instructions TO TURN OFF GAS TO APPLIANCE (page 33). Standby Mode (Pilot Flame)
* Press and hold ( (small flame) button to set appliance at pilot flame. To Turn OFF Appliance
* Press ON-OFF button. Flame Height Adjustment
* Press and hold () (large flame) button to increase flame height. Press and hold (\ (small flame) button to decrease flame height or to set appliance at pilot flame. If the appliance will not operate, follow the instructions TO TURN OFF GAS TO APPLIANCE (page 33). TO OPEN AND CLOSE SOLENOID VALVE/BURNER
* Simultaneously press the ON-OFF and ( (small flame) buttons to switch the Decorative Burner OFF. Simultaneously press ON-OFF and () (large flame) buttons but-
tons to switch Decorative Burner on. NOTE: The latching solenoid valve cannot operate manually. If the receiver battery runs down it will remain in the last operating position. 32/33 Standby Mode (Pilot Flame) Press and hold C button to set appliance at pilot flame. To Turn OFF Appliance
= Press B button. Flame Height Adjustment
= Press and hold A button to increase flame height.
* Press and hold C button to decrease flame height or to set appliance at pilot flame. If the appliance will not operate, follow the instructions TO TURN OFF GAS TO APPLIANCE? (page 33). TO OPEN AND CLOSE SOLENOID VALVE/ BURNER
= Simultaneously press the B and C buttons to switch the Dec-
orative Burner OFF.
* Simultaneously press B and A buttons buttons to switch Decorative Burner on. NOTE: The latching solenoid valve cannot operate manually. If the receiver battery runs down it will remain in the last operating position. 2016 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved. OPERATING INSTRUCTIONS FOR OEM USE ONLY 2016 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved. MANUAL OPERATION
(Only possible, when MANUAL knob is used) Access to the pilot burner is only required for ignition with a match. When turning main valve knob, do not force. Knob has a slip clutch that clicks until the end stops are reached. This allows for manual flame height adjustment as well as adjustment to pilot standby position. 1. STOP! Read the safety information included before proceeding. 2. Turn main valve knob to the OFF, full clockwise > position. 3. Turn MANUAL knob to the MAN, full clockwise FY position. 4. Place ON/OFF switch (if equipped) in O (OFF) position. 5. Wait five (5) minutes to clear out any gas. Verify that no gas is in the area around the appliance, including near the floor. If you detect gas STOP! Follow WHAT TO DO IF YOU SMELL GAS in the safety information on page 2. If no gas is present, proceed to step 6. 6. Place ON/OFF switch (if equipped) in | (ON) position. 7. With the MANUAL knob in MAN position a manual pilot valve operator and piezo ignitor (optional) are accessible. 8. Fully push down manual pilot valve operator and hold in, to start pilot gas flow (see figure 32). Ignition with match:
Immediately light the pilot with a match, while continuing to hold in the manual pilot valve operator for about one (1) minute after the pilot is lit. Release manual pilot valve operator. If pilot does not stay lit, wait five (5) minutes and repeat. Ignition with piezo ignitor:
Change the ignition cable from the receiver to the valve. Push in the piezo ignitor to ignite. If pilot does not stay lit, wait five (5) minutes and repeat. If the pilot does not stay lit after several tries, turn the gas control knob (main valve knob) to OFF and proceed to step 12. 9. If applicable, replace pilot access panel before proceeding. 10. Turn MANUAL knob to the ON, full counterclockwise <-~O position. 11. Turn main valve knob to the full ON, full counterclockwise
<> position. 12. If the appliance will not operate, follow the instructions TO TURN OFF GAS TO APPLIANCE (below). Piezo Ignitor Connection
(optional) Piezo Ignitor Tab 2.8 x 0.8mm ON/OFF Switch
(optional) in MANUAL Knob ON Position in MAN Position 8 Wire Manual Pilot Receiver Jack Valve Operator Microswitch Main Valve Knob in OFF Position Figure 32: Combination control, cover TO TURN OFF GAS TO APPLIANCE 1.Place ON/OFF switch (if equipped) in O (OFF) position. 2. If gas control is accessible turn main valve knob to the OFF full clockwise 7, position. AUTOMATIC TURN DOWN TO PILOT 3 Hour No Communication Function The valve will turn to pilot flame if there is no communication between handset and receiver for a 3 hour period. The fire will continue to function normally when communication is restored. Receiver Overheating Valve turns to pilot flame if the temperature in the receiver is higher than 140F (60C), when the receiver:
= is powered by batteries and/or
* is connected to V Module. The main burner turns back on (manually or in Thermostatic Mode) only when the temperature is below 140F (60C). 1 Hour Turn Down
(optional; requires special receiver and handset software)
= The valve will turn to pilot flame if there is no motor movement over a 1 hour period. AUTOMATIC SHUT OFF Countdown Timer
= At end of countdown time period, the fire turns off. The Count-
down Timer only works in Manual, Thermostatic, and Eco Modes. Maximum countdown time is 9 hours and 50 minutes Low Battery Receiver
= With low battery power in the receiver the system shuts off the fire completely. This will not happen if the power supply is inter-
rupted. On-Demand Pilot
* This green feature eliminates gas energy consumption during extended appliance inactivity. When the appliance is inactive for an extended period of time the system automatically extin-
guishes the pilot. This feature helps the consumer realize cost benefits by automatically eliminating energy consumption dur-
ing non-heating months and limited use. The programmed length of inactivity to activate the system is specified by the appliance manufacturer and cannot be altered in the field. 2* Thermocouple Shut Off
(optional)
= The system shuts off the fire if the main burner does not com-
pletely ignite approximately 20 seconds after ignition or after pushing (@) button. NOTE: Before the next ignition there is a 2 minute waiting pe-
riod. If the thermocouple is then still too hot, you will hear a long beep. 33/33 MERTIK MAXITROL mMmAXITROL Exclusive Distributor Europe for Maxitrol Company Mertik Maxitrol GmbH & Co.KG Warnstedter Str. 3, 06502 Thale GERMANY Tel: +49 3947 400-0 Fax: +49 3947 400-200 www.mertikmaxitrol.com GV60-II.Ol-EN-04.2016-SYMAX DRAFT Exclusive Distributor North America for Mertik Maxitrol Maxitrol Company 23555 Telegraph Rd., PO Box 2230 Southfield, Ml 48037-2230 USA Tel: +1 248-356-1400 Fax: +1 248-356-0829 www.maxitrol.com 2016 Mertik Maxitrol GmbH & Co. KG, All Rights Reserved.
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2016-08-10 | 915 ~ 915 | DXT - Part 15 Low Power Transceiver, Rx Verified | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2016-08-10
|
||||
1 | Applicant's complete, legal business name |
Mertik Maxitrol GmbH & Co. KG
|
||||
1 | FCC Registration Number (FRN) |
0010228450
|
||||
1 | Physical Address |
Warnstedter Strasse 3
|
||||
1 |
06502 Thale, N/A
|
|||||
1 |
Germany
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
h******@acbcert.com
|
||||
1 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
RTD
|
||||
1 | Equipment Product Code |
B6RH9P
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
B**** H******
|
||||
1 | Title |
Group Leader Development Gas Controls
|
||||
1 | Telephone Number |
49 39********
|
||||
1 | Fax Number |
49 39********
|
||||
1 |
b******@mertikmaxitrol.de
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DXT - Part 15 Low Power Transceiver, Rx Verified | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Handset unit for gas burning applications (room heaters) | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
CSA Group Bayern GmbH
|
||||
1 | Name |
F******** S****
|
||||
1 | Telephone Number |
49-94********
|
||||
1 | Fax Number |
49-94********
|
||||
1 |
f******@csagroup.org
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 915.00000000 | 915.00000000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC