5.Notice FCC: VPYLB1FS IC: 772C-LB1FS M/N: LBEE5UW1FS For OEM integration only device cannot be sold to general public. Therefore we will ask OEM to include the following statements required by FCC/IC on the product and in the Installation manual Notice. Please describe the following warning on the final product which contains this module. Confidential FCC) Contains Transmitter Module FCC ID:VPYLB1FS IC) Contains Transmitter Module IC : 772C-LB1FS or or Contains FCC ID:VPYLB1FS Contains IC : 772C-LB1FS This device complies with Part 15 of FCC Rules and Industry Canadas licence-exempt RSSs. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. Le prsent metteur radio IC: 772C-LB1FS (LBEE5UW1FS) a t approuv par Industrie Canada pour fonctionner avec les types d'antenne numrs ci-dessous et ayant un gain admissible maximal. Les types d'antenne non inclus dans cette liste, et dont le gain est suprieur au gain maximal indiqu, sont strictement interdits pour l'exploitation de l'metteur. 1) l'appareil ne doit pas produire de brouillage, et 2) l'appareil doit accepter tout brouillage subi, mme si le brouillage est susceptible d' en compromettre le fonctionnement.
When the product is small, as for these words mentioned above, the posting to a manual is possible. Copyright Murata Manufacturing Co., Ltd. All rights reserved. 14 January 2016 5 5.Notice Confidential This radio transmitter IC: 772C-LB1FS (LBEE5UW1FS) has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Antenna type: Pattern Antenna Gain: 0.7dBi (55mm cable)
0.7dBi (58mm cable)
-2.1dBi (100mm cable) Le prsent metteur radio IC: 772C-LB1FS (LBEE5UW1FS) a t approuv par Industrie Canada pour fonctionner avec les types d'antenne numrs ci-dessous et ayant un gain admissible maximal. Les types d'antenne non inclus dans cette liste, et dont le gain est suprieur au gain maximal indiqu, sont strictement interdits pour l'exploitation de l'metteur. Type dantenne: Motif antenne Gain: + 0.7dBi (cble de 55mm)
+ 0.7dBi (cble de 58mm)
-2.1dBi (Cble de 100mm)
Please describe the following warning to the manual. FCC CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. This transmitter must not be co-located or operated in conjunction with any other antenna or transmitter. Copyright Murata Manufacturing Co., Ltd. All rights reserved. 14 January 2016 6 Confidential 5.Notice Please describe the following warning to the manual.
When installing it in a mobile equipment. This equipment complies with FCC/IC radiation exposure limits set forth for an uncontrolled environment and meets the FCC radio frequency (RF) Exposure Guidelines and RSS-102 of the IC radio frequency (RF) Exposure rules. This equipment should be installed and operated keeping the radiator at least 20cm or more away from persons body. Cet quipement est conforme aux limites dexposition aux rayonnements nonces pour un environnement non contrl et respecte les rgles les radiolectriques (RF) de la FCC lignes directrices d'exposition et dexposition aux frquences radiolectriques (RF) CNR-102 de lIC. Cet quipement doit tre install et utilis en gardant une distance de 20 cm ou plus entre le radiateur et le corps humain.
When installing it in a portable equipment. The available scientific evidence does not show that any health problems are associated with using low power wireless devices. There is no proof, however, that these low power wireless devices are absolutely safe. Low power Wireless devices emit low levels of radio frequency energy (RF) in the microwave range while being used. Whereas high levels of RF can produce health effects (by heating tissue), exposure of low-level RF that does not produce heating effects causes no known adverse health effects. Many studies of low-level RF exposures have not found any biological effects. Some studies have suggested that some biological effects might occur, but such findings have not been confirmed by additional research. LBEE5UW1FS has been tested and found to comply with FCC/IC radiation exposure limits set forth for an uncontrolled environment and meets the FCC radio frequency (RF) Exposure Guidelines and RSS-102 of the IC radio frequency (RF) Exposure rules. Les connaissances scientifiques dont nous disposons nont mis en vidence aucun problme de sant associ lusage des appareils sans fil faible puissance. Nous ne sommes cependant pas en mesure de prouver que ces appareils sans fil faible puissance sont entirement sans danger. Les appareils sans fil faible puissance mettent une nergie frquence radiolectrique (RF) trs faible dans le spectre des micro-ondes lorsquils sont utiliss. Alors quune dose leve de RF peut avoir des effets sur la sant (en chauffant les tissus), lexposition de faibles RF qui ne produisent pas de chaleur na pas de mauvais effets connus sur la sant. De nombreuses tudes ont t menes sur les expositions aux RF faibles et nont dcouvert aucun effet biologique. Certaines tudes ont suggr quil pouvait y avoir certains effets biologiques, mais ces rsultats nont pas t confirms par des recherches supplmentaires. LBEE5UW1FS a t test et jug conforme aux limites dexposition aux rayonnements nonces pour un environnement non contrl et respecte les rgles les radiolectriques (RF) de la FCC lignes directrices d'exposition et dexposition aux frquences radiolectriques (RF) CNR-102 de lIC. Note) Portable equipment : Equipment for which the spaces between human body and antenna are used within 20cm. Mobile equipment : Equipment used at position in which the spaces between human body and antenna exceeded 20cm. Copyright Murata Manufacturing Co., Ltd. All rights reserved. 14 January 2016 7