Issue Department System Instruction Date Author 2019.01.07 Instruction of RF27 Edition V0.0 Page 1 of 5 Instruction of RF27 1 Key description 1.1 appearance Figure1buttonofremote
1/5 Issue Department System Instruction Date Author 2019.01.07 Instruction of RF27 Edition V0.0 Page 2 of 5 2 Key description Buttons
&LEDs B1 B2 Key value Specification CHILD LOCK Press and hold child lock button till the backlight flashes remote enters locking or unlocking mode. PAIR press and hold pair button ,the remote enters pairing mode 2/5 Issue Department System Instruction Date Author 2019.01.07 Instruction of RF27 Edition V0.0 Page 3 of 5 B3 M B4 FLASH LIGHT B5 ZG B6 HEAD UP B7 TV/PC B8 B9 FOOT UP FLAT B10 FOOTDOWN B11 ANTI SNORE B12 HEAD DOWN B13 LOUNGE B14 MASSAGE HEAD Click M button, the bed moves to M position, press and hold M button for 5s, until backlight flashes, the control set the current position as M position Click FLASH LIGHT button, open or close flash light Click zeroG button, the bed moves to zeroG position, press and hold zeroG button for 5s, until backlight flashes, the control set the current position as zeroG position Press and hold head up button, head actuator moves out, stop when released Click TV/PC button, the bed moves to TV/PC position, press and hold TV/PC button for 5s, until backlight flashes, the control set the current position as TV/PC position Press and hold foot up button, foot actuator moves out, stop when released Press and hold flat button, the bed goes flat Press and hold foot down button,foot actuator moves out, stop when released Click antisnore button, the bed moves to antisnore position, press and hold antisnore button for 5s until backlight flashes, the control set the current position as antisnore position Press and hold head down button, head actuator moves out, stop when released Click lounge button, the bed moves to lounge position, press and hold lounge button for 5s, until backlight flashes, the control set the current position as lounge position Click massage head button to switch massage intensity of head massage motors B15 TIMER Click timer button to switch massage time B16 MASSAGE FOOT Click massage foot button to switch massage 3/5 Issue Department System Instruction Date Author 2019.01.07 Instruction of RF27 Edition V0.0 Page 4 of 5 intensity of foot massage motors B17 B18 MASSAGE ON/OFF UNDER BED LIGHT Click massage on/off button to turn on/off head &
foot massage motors Click under bed light button to turn on/off the under bed light B19 MASSAGE TYPE Click massage type button to switch massage mode LED 1 LED 2 LED 3 LED 1 LED 2 LED 3 Massage time: 10 minutes Massage time: 20 minutes Massage time: 30 minutes Other function 1:
Zero G + Flat Press and hold zeroG and flat button for 5s until backlight flashes, the memory positions of control box reset to default settings FCC Warning Any Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 4/5 Issue Department System Instruction Date Author 2019.01.07 Instruction of RF27 Edition V0.0 Page 5 of 5 ISED RSS Warning:
interference, and (2) this device must accept any This device complies with Innovation,Science and Economic Development Canada licenceexemptRSS standard(s). Operation is subject to the following two conditions: (1) this devicemay not cause interference, includinginterference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR d'ISED applicables aux appareils radioexempts de licence. L'exploitation est autorise aux deux conditions suivantes:
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi,mme si le brouillage est susceptible d'en compromettre le fonctionnement. ISED RF exposure statement:
This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment.The device has been evaluated to meet general RF exposure requirement. Le matriel est conforme aux limites de dose d'exposition aux rayonnements noncs pour fac un autre environnement.ce dispositif a t valu satisfaire l'exigence gnrale de l'exposition aux rf. 5/5 FCC ID: PCU-RF27 IC: 21319-RF27 JLDP.14.027.000 JLDP.05.032.000 R5.216.01.015C JLDP.10.023.000 R5.504.01.250 R5.217.01.016 R5.413.01.005 R5.113.00.011 CB.13.22.01 FCC ID: PCU-CB1322 IC: 21319-CB1322 R5.410.01.009 JLDQ.9.001.130C B.15227 B.15226 NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Product name Product code number Head Motor Foot Motor Massage Motor Massage Motor Cable Control Box Power Supply Power Cord ANSI power cord Y cable Patch cord of LED strip LED strip/ LED USB Socket/USB Double USB Chager 19Keys remote B.15227 B.15226 JLDQ.9.001.130C R5.410.01.009 CB.13.22.01 JLDP.10.023.000 R5.217.01.016 R5.504.01.250 R5.216.01.015C R5.413.01.005 R5.113.00.011 JLDP.05.032.000 JLDP.14.027.000 RF27 1 1 2 1 1 1 1 1 1 1 1 1 2 1