WELCOME TO QUICK START GUIDE HT25G2ASR Contents Hose Faucet Timer Quick Start Guide 1) Open the B-hyve App Log into your B-hyve account and tap My B-hyve. Go to devices then add device. The app will walk you through the rest of the process. For new users, search apps for B-hyve and download the free Android or iOS app. Create an account to begin setup. 2) Power Your Hose Faucet Timer Insert two new AA Batteries*, the timer is now in pairing mode and will flash a blue light every 5 seconds. You will also hear two clicks about 6 seconds apart, this is normal and ensures the valve is closed before you turn on the water. Write down the MAC address: 12 digit alphanumeric code on the bottom of the timer. Timer MAC Address:
If at any time you need to re-pair or do a factory reset, press the on/off button quickly 5 times.
*Batteries are sold separately. Replace batteries when timer flashes a red light every 5 seconds, or when the app notifies you that batteries need replacing. If you remove or change the batteries you will need to reconnect to Bluetooth to set the correct time and date. 3) Install the Timer Your timer is now ready to be used with any product that can be attached to a standard hose faucet. Do not place the timer in an underground valve box. 4) Turn on Your Water The water must remain on for the timer to work properly. Manual Watering Simply press and hold the on/off button for 5 seconds to activate manual watering. Need to stop watering, even during a programmed time? Press the on/off button once to stop watering. Orbit 1.801.299.5555 orbitonline.com M C Y K DATE: 11/29/2021 DESIGNER: QW MARKETING: CD ARTWORK : 21205-24 rA SOFTWARE: Adobe Indesign CC Dieline PMS CG 10 C Dims./
Callout PMS 7405 C Fold PMS 0000 Product Coverage PMS 0000 Glue PRINTERS ARE REQUIRED TO MATCH ALL SPECIFIED PMS COLORS. Folded Flat Additional Information L:
W:
3.75"
H:
2.75"
W:
10.25"
H:
5.5"
Printers are responsible for meeting print production requirements. Any changes must be approved by Orbit. Printed piece must meet designated specifications on this form. 2020 Orbit Inc. This work is the property of Orbit, and cannot be used, reproduced or distributed in any way without their express permission. Timer Range: 150 ft without interference Pressure Operating Range: 10-100 PSI Temperature Operating Range:
32F-158F (0-70C) For Outdoor Use With Cold Water Only Not For Use With Appliances Do Not Mix Alkaline, Standard (Carbon-Zinc), or Rechargeable
(Nickel Cadmium) Batteries. Used up or dead batteries must be removed from the timer and disposed of properly. Do not dispose of batteries in fire. Batteries may explode or leak. FCC ID: ML6HT25ASR FCC Statement:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Warning: Any changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate this equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and the receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This device meets the FCC and IC requirements for RF exposure in public or controlled environments. The end user is advised to maintain a distance 20 cm from the timer and any personnel to ensure compliance with RF exposure regulations. IC: 3330A-HT25ASR IC Statement:
This device complies with Industry Canada license exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This Class B digital apparatus complies with Canadian ICES-003. Remarque: cet appareil t test et dclar conforme aux limites dexposition pour les appareils numriques de classe B, selon la section 15 de la Rglementation de la FCC. Ces limites sont conus pour fournir une protection raisonnable contre les interfrences nuisibles dans une installation rsidentielle. Cet appareil produit, utilise et peut mettre de lnergie radio frquence et, si elle nest pas installe et utilise conformment aux instructions, peut causer des interfrences nuisibles aux communications radio. Cependant, il nest pas garantie que des interfrences ne se produisent pas dans une installation particulire. Si cet appareil cause des interfrences gnantes la rception dun signal radio ou de tlvision, ce qui peut tre dtermin en allumant et en teignant lappareil, lutilisateur peut corriger les interfrences en suivants une des mesures suivantes :
Rorientez ou repositionnez lantenne de rception. Augmentez la distance entre lappareil et le rcepteur. Branchez lappareil dans une prise sur un circuit diffrent du circuit sur lequel le rcepteur est branch. Consulter le revendeur ou un technicien radio/TV expriment pour obtenirde laide. Cet appareil est conforme aux exigences de la FCC et de lIC concernant lexposition aux ondes dans un environnement public ou contrl. Il est conseill lutilisateur final de maintenir une distance de 20 cm du contrleur pour assurer la conformit aux rglementations dexposition RF. Information de conformit pour le Canada Dclaration de lIC : Cet appareil est conforme la norme RSS dIndustry Canada. Son fonctionnement est soumis aux deux conditions suivantes : (1) cet appareil ne doit pas causer dinterfrences nuisibles, et (2) cet appareil doit tolrer toutes les interfrences, dont les interfrences pouvant causer un fonctionnementnon dsir. Cet appareil numrique de classe B est conforme la norme canadienneICES-003. Need Help?
If you encounter a problem, please use the following resources before retuning your B-hyve to the store. call us email us text us 1-801-299-5555 support@orbitbhyve.com 801-905-8260 Scan the QR Code for access to a full user manual, videos, and more. 21205-24 rA