PAN05-1/-2/-3 In Wall Single relay(1 way) switch module P There are many kind of application by using the module to switch Load On and Off , one main application is the light control. If connect the com port directly to AC Line terminal ,the new smart relay calibration technology can reduce the inrush current caused by the load and let the module work perfectly with many kind of light like incandescent, fluorescent and LED light. This module can also connect to alternative power supply like DC 12V to switch on/off 12V MR-16 light as follow picture. Adding to Z-WaveTM Network In the front casing, there is an on/off button with LED indicator below which is used to toggle switch on and off or carries out inclusion, exclusion, reset or association. After being excluded, its LED flashes on and off alternately and repeatedly at 2-second in-
tervals. It implies that it has not been assigned a node ID and cannot work with Z-
Wave enabled devices. Fig 1. Assembling Auto Inclusion This in-wall switch module is a transceiver which is a Z-WaveTM enabled device and is fully compatible with any Z-WaveTM enabled network. Mini size design let the module can easily hide itself into the wall box and that will be good for the house decoration. The function of auto inclusion will be executed as long as the in wall switch does not have Node ID and just connect the switch to main power. Note: Auto inclusion timeout is 2 minute during which the node information of explorer frame will be emitted once every 5 seconds. Unlike inclusion function as 1 shown in the table below, the execution of auto inclusion is free from pressing the On/Off button on the Switch. seconds until LED is off. 3. IDs are excluded. The table below lists an operation summary of basic Z-Wave functions. Please refer to the instructions for your Z-WaveTM Certificated Primary Controller to access the Setup function, and to include/exclude/associate devices Function No node ID Description The Z-Wave Controller does not allocate a node ID to the Switch. LED Indication 2-second on, 2-second off Inclusion 1. Have Z-Wave Controller entered One press one flash inclusion mode. 2. Pressing Include button of PAN05 three times within 2 seconds will enter inclusion mode. Exclusion 1. Have Z-Wave Controller entered One press one flash exclusion mode. 2. Pressing Include button of PAN05 three times within 2 seconds will enter exclusion mode. Node ID has been excluded. 2-second on, 2-second off Reset 1. Pressing Include button of PAN05 three times within 2 seconds will enter inclusion mode. 2. Within 1 second, press Include button of PAN05 again for 5 Association 1. Have Z-Wave Controller entered One press one flash association mode. Or Pressing Include button of PAN05 three times within 2 seconds will enter association mode 2. There are only 1 group for the switch Including a node ID allocated by Z-Wave Controller means inclusion. Excluding a node ID allocated by Z-Wave Controller means exclusion. Failed or success in including/excluding the node ID can be viewed from the Z-Wave Controller. Sometimes people are not easy to execute exclusion or inclusion especially when PAN05 already installed in a wall box. To solve this issue, PAN05 support a special feature that can use S1 or S2 to execute exclusion, inclusion, Reset or Association at the first 3 minutes when first time connect to main power. LED Indication To distinguish what mode the switch is in, view from the LED for identification. State Type Normal LED Indication Whenever we switch On and off of the PAN05 by S1 S2 or On/Off button or RF command , the LED will lights up 1 second and then 2 No node ID Learning off. Under normal operation, when the Switch has not been allocated a node ID, the LED flashes on and off alternately at 2-second intervals. By pressing S1 S2 or On/Off button, it will stop flashing temporarily. However, after disconnect and reconnect the Switch, the LED will flash on and off alternately at 2-second intervals. When PAB01 is in learning mode, LED flashes on and off alternately and repeatedly at 0.5 second intervals. Choosing a Suitable Location 1. Do not locate the Switch facing direct sunlight, humid or dusty place. 2. The suitable ambient temperature for the Switch is 0C~40C. 3. Do not locate the Switch where exists combustible substances or any source of heat, e.g. fires, radiators, boiler etc. 4. After putting it into use, the body of Switch will become a little bit hot of which phenomenon is normal. Installation 1. Put the in wall switch into a wall box and connect the AC power wire L,N to PAN05 connector L, N. 2. Connect the wall switch to the PAN05 as Fig1 . 3. There are 3 mode PAN05 can be configured to match different kind of wall switch, please refer to 3-1 Edge / Pulse / Edge-Toggle mode which described in next section of this user manual. If Edge-Toggle mode has been set, and the S1 S2 is connect to normal bi-stable switch, every time when change the state of the wall switch will also swap the state of Relay1. 4. Programming 1. Basic Command Class / Binary Switch Command Class The Switch will respond to BASIC and BINARY commands that are part of the Z-
3 Wave system. load attached to the Switch turns off. 1-1 BASIC_GET / BINARY_SWITCH_GET 2. Z-Waves Groups (Association Command Class Version 1) Basic Get Command: [Command Class Basic, Basic Get]
Basic Report Command:
Report OFF: [Command Class Basic, Basic Report, Value = 0(0x00)]
Report ON:[Command Class Basic, Basic Report, Value = (255)0xFF]
Binary Switch Get Command:[Command Class Switch Binary, Switch Binary Get]
Binary Switch Report Command:
Report OFF:[Command Class Switch Binary, Switch Binary Report, Value
=0(0x00)]
Report ON:[Command Class Switch Binary, Switch Binary Report, Value =
(255)0xFF]
1-2 BASIC_SET / SWITCH_BINARY_SET
[Command Class Basic, Basic Set, Value = (255)0xFF]: the load attached to the Switch turns on.
[Command Class Basic, Basic Set, Value = 0(0x00)]: the load attached to the Switch turns off.
[Command Class Switch Binary, Switch Binary Set, Value = (255)0xFF]:
the load attached to the Switch turns on.
[Command Class Switch Binary, Switch Binary Set, Value = 0(0x00)]: the The Switch can be set to send reports to control associated Z-Wave devices. It supports only one association group and the group has one node support. Group1 support SWITCH_BINARY_REPORT, BASIC_REPORT. For group 1, the Switch will report ON/OFF status of Relay1 2-1 Auto report to Grouping 1 (Maximum Node 1) 2-1-1 On/Off Event Report When on or off state has been changed (ex. Press S1 S2 or include on/off button), it will send Binary Switch Report to the nodes of Group1. Binary Switch Report ON:[Command Class Switch Binary, Switch Binary Report, Value
=(255)0xFF]
OFF:[Command Class Switch Binary, Switch Binary Report, Value
=0(0x00)]
2-1-2 Overload alarm report command When PAN05 detect the overload, it will send Alarm Report to the correspond Group. 4 The content of Alarm Report Alarm report command:[Command Class Alarm, Alarm Report, Alarm Type
= 0x08, Alarm Level = 0xFF]
8 9 1 1 Auto off timer RF Off command mode 0-
0x7FFF 0-3 Second 0 0 0Disable auto off function 1-0x7FFF1 ~
32767seconds 0Switch off 1Ignore 2Switch toggle 3Switch on 3. Z-Waves Configuration Configuration Parameter 1 5 6 7 Function Size Value Unit Default Description
(Byte) 1 1-3 1 1 1 0-2 0-1 1-2 Edge or Pulse mode or Edge-Tog gle mode Restore switch state mode Manual On/Off mode LED indication mode 1 1 1 1 1Edge mode 2Pulse mode 3Edge-Toggle mode 0 : Switch Off 1 : Last Switch State 2 : Switch On 0Disable manual On/Off 1Enable manual On/Off 1Show switch 2Show night state mode 3-1 Edge / Pulse / Edge-Toggle mode Manual switch S1 and S2 can set to Edge mode or Pulse mode or Edge-Toggle mode , default value is Edge mode. Edge mode: this mode is suitable for the bi stable wall switch that has indicator point on the switch, and the same position correspond to same state of relay1. if the PAN05 relay change the state because of receiving Z-Wave RF command, it may need two times of change (switch on to off or switch off to on) to let relay back to the correspond state. Manual switch S2 is disabled in this mode. Pulse mode: this mode is suitable for the toggle type wall switch to swap the state of Relay1. Edge-Toggle mode: this mode is suitable for the normal bi-stable switch, every time when change the state of the wall switch will also swap the state of Relay1. 3-2 Restore Switch State Mode Whenever the AC power reconnected to PAN05, it will set the switch to OffOn or Last switch state, default value is Last switch state. 3-3 Manual On/Off Mode The On/Off function of S1S2 and learn switch can be disabled or enabled by this parameter, default value is Enable. 5 3-4 LED indication Mode Show switch stateLED on for switch on and off for switch off. Show switch stateLED off for switch on and on for switch off. The default value is Show switch state. 3-5 Auto Off timer When auto off timer is equal to 0, the auto off function will be disabled. Whenever the switch is set to on, the auto off timer begin to count down. After the timer counts to zero, PAN05 will switch off automatically. The default value is disable auto off function. 3-6 RF Off command mode Whenever a RF Off command is received, it could be interpreted as Switch OffSwitch OnSwitch Toggle, or it would be ignored. The default value is Switch Off. 4. Command Classes The Switch supports Command Classes including
* COMMAND_CLASS_ZWAVEPLUS_INFO
* COMMAND_CLASS_VERSION
* COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
* COMMAND_CLASS_DEVICE_RESET_LOCALLY
* COMMAND_CLASS_ASSOCIATION_V2
* COMMAND_CLASS_ASSOCIATION_GRP_INFO
* COMMAND_CLASS_POWERLEVEL
* COMMAND_CLASS_SWITCH_BINARY
* COMMAND_CLASS_BASIC
* COMMAND_CLASS_SWITCH_ALL
* COMMAND_CLASS_CONFIGURATION
* COMMAND_CLASS_ALARM
* COMMAND_CLASS_SCENE_ACTIVATION
* COMMAND_CLASS_SCENE_ACTUATOR_CONF
* COMMAND_CLASS_PROTECTION
* COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 Troubleshooting Symptom The Switch not working and LED off The Switch LED illuminating, but cannot control the ON/OFF Switch of the load attached Cause of Failure Recommendation 1. The Switch is not connect to the Main power 2. The Switch break down Check if the load connect into the Switch has its own ON/OFF switch 1. Check power connections 2. Dont open up the Switch and send it for repair. Set the ON/OFF switch of the load attached to ON The Switch LED illuminating, but the Detector cannot control 1. Not carry out association 2. Same frequency 1. Carry out association 2. Wait for a while to re-try 6 the Switch LED keep flashing continuously, but cannot control interference Overload occurs Remove the load attached or check max. load cannot exceed 11A(230Vac/120Vac) Disposal Specification Operating Voltage 100 ~240VAC Maximum Load 11A(230Vac/120Vac) Range Minimum 30 m in door 100m outdoor line of sight Operating Temperature 0C ~ 40C Frequency Range PAN05-1: 868.40MHz; 869.85MHz(EU) /
PAN05-2 908.40MHz; 916.00MHz(USA/Canada) /
PAN05-3 922.5MHz/ 923.9MHz/ 926.3MHz (Taiwan/JP)
** Specifications are subject to change and improvement without notice. FCC ID : RHHPAN05 Warning:
1.Plug out to disconnect from power supply; Do not plug in line. 2. Do not exceed the max rating This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling. Company of License HolderPhilio Technology Corporation Address of License Holder8F.,No.653-2,Zhongzheng Rd., Xinzhuang Dist., New Taipei City 24257,Taiwan(R.O.C) FCC Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is 7 encouraged to try to correct the interference by one of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. 8