DOCUMENTATIONS CENTER PRODUCT DATASHEET LoRaWAN 3-in- I IAQ (Temperature+Humidity+CO2) Smart Sensor Terminal with WxS8813-423071 4.2" Ink Display (Indoor, ER18505H/M) Product Highlights LoRaWAN 3-in- I IAQ (Temperature+Humidity+CO2) Smart Sensor Terminal with 4.2" Ink Display (Indoor, ER18505H/M) Battery powered (ER18505M/ER18505H) Ultralow power design, batteries powered up to 10 years Temperature , humidity and CO2 (temperature: - 40 ~125 ; humidity: 0~100%
RH;CO2:0-5,000ppm) in the environment can be monitored and transmitted in real time Terminal and sensor parameters configurable with Configuration Tool running on PC o LoRaWAN ISM Global Bands Supported and SW Configurable o LoRaWAN Uplink Transmission Cycle Configurable o Sensor Parameters Configurable o Sensor Data Report Cycle Configurable FOTA (Over The Air) firmware upgrade, including to upgrade loader and application images OTA (Over The Air) terminal running parameters supported Integrated internal antenna, or optional external SMA/IPEX antenna The transmission reaches 5km in NLoS (non-line of sight) and 18km in LoS (line of sight) environment Optional (Public/Private) IoT cloud platform PolySuite iView and LoRaWAN network iServer LoRaWAN Compliance Specifications Parameters Smart Terminal Data Report Wireless ISM Regional Parameters Value MQTT Protocol, Jason format;
Cross-threshold report, plus periodic report (the threshold and the periodic report cycle are both user-configurable) AS923 (AS923-1, AS923-2, AS923-3, AS923-4) AU915 CN470 CN779 EU433 EU868 IN865 KR920 RU864 US915 Polysense Technologies Inc. Proprietary and Open Page 1 DOCUMENTATIONS CENTER PRODUCT DATASHEET Maximum Link Budget Distance Antenna Mechanical Dimension IP Grade Operating Temperature Total Weight Electrical Supply Voltage Power Type Compliance/Certification 168dB Up to 5km in NLOS; up to 18km in LOS Integrated internal antenna or external 1/2 wavelength whip antenna
(SMA) 100*86*28mm IP30
-40C to +85C 120 g 3.6VDC 2*ER18505M/H Products includes following parts:
PST-xx13-423071 3-in-1 IAQ (Temperature+Humidity+CO2) Smart Sensor Terminal with 4.2" Ink Display (Indoor, ER18505H/M) WxS88xx WxS Terminal LoRa Communications Board Configuration Tool iEdge4.0 WxS IoT Terminal products can be configured with PolySuite software-visual based Configuration Tool or CLI interface command or OTA via IoT platform, such as PolySuite PaaS platform iView. Download link http://ota.polysense.online/wincc/ConfigurationTool.rar Product Image Polysense Technologies Inc. Proprietary and Open Page 2 DOCUMENTATIONS CENTER PRODUCT DATASHEET 3-in-1 IAQ (Temperature+Humidity+CO2) Smart Sensor Terminal with 4.2" Ink PST-xx13-423071 Display (Indoor, ER18505H/M) Product introduction PST-xx13-423071 is a product with an ink screen display that integrates temperature, humidity and carbon dioxide sensors. Battery powered, it can detect carbon dioxide, temperature and humidity in the environment in real time.Mounted with screw or adhesive tape, suitable for indoor scenes. Detection principle Temperature and Humidity: Semiconductor CO2: advanced non dispersive infrared (NDIR) technology Product features Sensor parameters: ambient temperature and humidity, CO2 4.2 "ink screen, real-time display of temperature and humidity data Ultra low power design, battery powered up to 10 years Batteries: 2*ER18505 Product parameters Parameters Measuring range Temperature: - 40 125 Humidity: 0~100% RH CO2:0-5000ppm Temperature: 0 65 , 0.2 Other, 0.6 Humidity: 10~90%, 2% RH; Other, 4% RH CO2: (50ppm+5% reading) at 25 2 Temperature: 0.01 Humidity: 0.01%RH Temperature:>2s (T63%) Humidity: 86s Temperature:<0.03 /yr Humidity:<0.25% RH/yr Ink screen 4.2 100mm*86mm*28mm
- 10~50 ; Below 0~95% RH (non condensing)
- 30~60 ; Below 0~95% RH (non condensing) IP30 3.6V;
Replaceable ER18505M or ER18505H lithium battery Accuracy Resolution Response time Long term drift Display screen Mechanics Size Working conditions Storage conditions IP Grade Power Power Battery type Application It is widely used in indoor environment testing. Polysense Technologies Inc. Proprietary and Open Page 3 DOCUMENTATIONS CENTER PRODUCT DATASHEET Ordering Guide PST-xx13-423071 needs to be used together with WxS series communication boards (WxS88xx, WxS98xx and WxS99xx) to form intelligent IoT terminals with different communication modes;
Example of products are as follows:
4.2" Ink Display o WxS8813-423071 LoRaWAN Series IAQ (Temperature+Humidity+CO2) Smart Sensor Terminal with o WxS9813-423071 NB-IoT (China) Series IAQ (Temperature+Humidity+CO2) Smart Sensor Terminal o WxS9913-423071 NB-IoT (Global) Series IAQ (Temperature+Humidity+CO2) Smart Sensor Terminal with 4.2" Ink Display with 4.2" Ink Display FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Caution Any changes or modications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RF Exposure Information This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. Polysense Technologies Inc. Proprietary and Open Page 4