all | frequencies |
|
|
exhibits | applications |
---|---|---|---|---|---|
manuals |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
Installation Guide | Users Manual | 830.33 KiB | / February 04 2009 | |||
1 |
|
User Manual | Users Manual | 4.56 MiB | / February 04 2009 | |||
1 | Parts List/Tune Up Info | / February 04 2009 | ||||||
1 | Cover Letter(s) | / February 04 2009 | ||||||
1 | External Photos | / February 04 2009 | ||||||
1 | Internal Photos | / February 04 2009 | ||||||
1 | ID Label/Location Info | / February 04 2009 | ||||||
1 | ID Label/Location Info | / February 04 2009 | ||||||
1 | Cover Letter(s) | / February 04 2009 | ||||||
1 | RF Exposure Info | / February 04 2009 | ||||||
1 | Test Report | / February 04 2009 | ||||||
1 | Test Setup Photos | / February 04 2009 |
1 | Installation Guide | Users Manual | 830.33 KiB | / February 04 2009 |
Tsunami MP.16 3650 System Quick Installation Guide 3650 IMPORTANT This device must be installed by a trained professional, value added reseller or systems integrator who is familiar with RF planning issues and the regulatory limits. CAUTION!
Heed all the WARNINGS. Follow all the instructions. Do not defeat the safety purpose of the grounding. Only use attachments/accessories specified by the manufacturer. What is in the Kit SS with integrated antenna or BS/SS with external antenna connector (1 ea) Power Injector and Cord (1 ea) RJ45 to DB9 Serial Connector (1 ea) Mounting Hardware Kit (1 ea) Cable Termination Kit (1 ea) CD with User and Quick Installation Guide (1 ea) BS/SS Power Adaptor Serial Cable Installer CD 2. To wall-mount the unit, mount bracket E to a wall using 4 screws (not provided), as shown:
3 Determine Proper Mounting Orientation Locate the arrow on the back of the unit and determine your desired mounting orientation. For vertical polarization using the integrated antenna, the arrow should be pointing up (perpendicular to the ground). For horizontal polarization using the integrated antenna, the arrow should be horizontal (parallel to the ground). 6 Plug in the Cables 1. Plug one end of the CAT5 cable (A) into the RJ45 jack of the unit (B). 4 Assemble Mounting Hardware 1. Attach the mounting plate (A) using the provided screws and washers (Torque 9 Nm/75 in-
lbs), such that the units antenna will be vertically or horizontally polarized when mounted. 2. Attach the extension arm (B) to mounting plate (A) with the screw, nut, and washers provided, as shown below. The extension arm gives the unit more possible tilt, letting you adjust for azimuth or elevation over a larger angle. Mounting Clamp for Wall/Pole Extension Arm Mounting Plate Mounting Clamp for Pole 3. Attach the mounting bracket (C) to extension arm (B) with the screw, nut, and washers provided. Additional Items Required Wrenches, Screwdrivers, and tools as needed for mounting the unit. Grounding kits for the coax cable as it enters the shelter, if desired 1 Prepare for Installation Refer to the Installation and Management Guide to aid in choosing a proper installation location. Unpack the box and ensure all of the components are in the kit. Note down the serial number as it may be required for support. 2 Assemble the Cable You will be attaching an outdoor-rated 24 AWG CAT5 cable (diameter .114 to .250 inches/2.9 to 6.4 mm) (not provided) to the Power-over-Ethernet port on the back of the unit and weatherproofing the assembly later in the installation procedure. First, you must construct the cable and assemble the weatherproofing cable covers as described in the following steps. Proxim greatly simplifies this assembly process by offering pre-assembled CAT5 cable kits in 25m, 50m, and 75m lengths (part numbers 69819, 69820, and 69821, respectively). 1. Slide the sealing nut (A) over the bare end of the CAT5 cable. 2. Slide the lock nut (B) over the bare end of the CAT5 cable. 3. lide the sealing cap (C) over the bare end of the CAT5 cable. Make sure the red rubber gasket is inside the cap. 4. Apply two wraps of 0.5 wide Teflon tape around 4 the threads of the lock nut (B) that will go inside the sealing cap. Thread the lock nut (B) onto the sealing cap (C), and hand tighten. Terminate the RJ45 connectors (D) to both ends of the CAT5 cable; test for proper wiring using a straight-through cable. 5. 6. 4. Finally tighten the assembly (Torque 15 Nm/130 in-lbs). 5 Mount the Unit 1. To pole-mount, insert screws through bracket F and fasten around the pole to bracket E and secure (Torque 11 N.m/100 in-lbs). Longer bolts (not supplied) are required for mounting the units to a pole with a diameter larger than 3 inches. 2. Connect the free end of the CAT5 cable to the Data and Power Out port 2. on the power 3. injector. To connect the unit through a hub or a switch to a PC, connect a straight-3. through Ethernet cable between the network interface card in the PC and the hub, and between the hub and the RJ45 Data In port on the PoE adapter. To connect the unit directly to a PC, connect a cross-over Ethernet cable between the network interface card in the PC and the RJ45 Data In port on the power injector. 7 Power on the Unit The power adaptor provides Power-over-Ethernet (PoE), supplying electricity and wired connectivity to the unit over a single 24 AWG CAT5 (diameter .114 to .250 inches/2.9 to 6.4 mm). The unit is not 802.3af-compatible. Note that the Active Ethernet module provides +48 VDC over a standard CAT5 Ethernet cable. Once you have connected the power injector to the Ethernet cabling and plugged the power injector cord into an AC outlet, the unit is powered on. There is no ON/OFF switch on the unit. To remove power, unplug the AC cord from the AC outlet or disconnect the RJ45 connector from the Data and Power Out port on the power injector. Depressing the power adaptors Reload button for five seconds during power-up remotely resets BS/SS parameters affecting communication between the BS and SS to their factory default settings: IP address, subnet mask, user name, password, Ethernet speed/duplex, and VLAN mode. 8 View LED Two LED indicators are available on the Ethernet port of the unit. These LEDs display the activity of the Ethernet and RF links. LED State Off On Flashing Ethernet LED No Ethernet link Ethernet link is connected Packets are being received on Ethernet. RF (Wireless) LED Base Station Radio is off Radio is active
(transmitting downlink and receiving uplink) Unit is in standby Subscriber Station Radio is off Downlink synchronized. Increasing on-off speed indicates increasing RSNR. PN 76404 1 Copyrights 2009 Proxim Wireless 2 3 9 Align the Antenna Unit Initialization Antenna alignment is the process of physically aligning the antenna of the radio receiver and transmitter to have the best possible link established between them. The antenna alignment process is usually performed during installation and after major repairs. If you are installing external antennas, consult the documentation that accompanies the antenna for installation instructions. Note that you must weatherproof the antenna connectors as described in Weatherproof the Connectors. To ensure correct antenna alignment:
1. Perform a link budget calculation to obtain an expected signal level. A link budget calculator is available at http://support.proxim.com 2. Compare the calculation to the SNR value on the SS by logging into the SS Web interface and 3. clicking Monitor > Statistics > MAC Statistics. If needed, physically adjust the antenna, and refresh the. Monitor > Statistics > MAC Statistics page to take a new SNR reading. 10 Tighten the Cable 1. Apply two wraps of Teflon tape around the threads of the units RJ45 jack (A) in a clockwise direction. assembly (B). 2. Make sure that the red rubber gasket is still seated in the sealing cap of the sealing cap/lock nut 3. Slide the sealing cap/lock nut assembly (B) over the RJ45 jack (A) and thread onto enclosure. 4. 5. Hand tighten first, then use a pipe wrench or similar tool to tighten one more quarter turn. Tighten the lock nut (C) (Torque 4 N.m/35 in-lbs). Thread the sealing nut (D) onto the sealing cap/lock nut assembly (B) and tighten (Torque 3 N.m/25 in-lbs). 11 Weatherproof the Connectors 1. Remove the film liner from the rubber-based tape strip. 2. Stretch and wrap the tape around the connector tightly, starting below the connector cap and against the unit and wrapping in a clockwise direction. Wrap the tape once around the base of the connector cap. 3. Seal the tape tightly against the connector and the cable. 4. Apply a layer of black electrical tape (not provided) over the rubber-based tape for further protection. Make sure the electrical tape also extends beyond the rubber-based tape to seal it. 12 Install the Documentation and Software To install the documentation and software on a computer or network, insert the CD into the CD-
ROM drive. The installer starts automatically. If it does not, double click on the setup.exe on the installation CD. The following documentation and software products are installed. Click Start > All Programs > Tsunami > MP.16 3650 Documentation (in Docs subdirectory):
Installation and Management Guide Quick Installation Guide Safety and Regulatory Guide Recommended Antenna Guide Antenna Installation Guide MP.16 3650 Online Help All of these items are also available from C:\Program Files\Tsunami\MP.16 3650. Available from C:\Program Files\Tsunami\MP.16 3650:
Documentation (in Docs folder): See list above Help files (in Help folder; click on index.htm to access) TFTP Server (in Extras folder) 1. Open a Web browser on a network computer. 2. Enter the units IP address in the browsers Address field and press Enter or Go. The default IP address of the BS is https:\192.168.10.1. The default IP address of the SS is https:\192.168.10.2. 3. To log in as an administrator, enter admin in the User Name field. Enter the password in the Password field. For new units, the default administrator password is public. To log in as a user, enter user in the User Name field. Enter the password in the Password field. For new units, the default password is public. 4. Proxim strongly recommends that you change these passwords to more secure ones. Refer to the the Tsunami MP.16 3650 System User Guide for instructions. 5. Click on any of the menu items on the left side of the screen to begin configuring the unit. Web Interface Navigation 1. Menu: Use the collapsible menu on the left of your screen to navigate through the web interface. For headings (marked with a folder icon:
heading to expand its contents (
used for configuring the unit.
) click on the arrow to the left of the
). Configuration pages (marked with a page icon:) are 2. Configuration parameters: View and change the units settings in the work area. Enter required or desired values in available fields, or use drop down menus to make selections. When you have configured a page, you must click the OK button to save your changes. If you do not click the OK button, the configuration parameters you specified will not be set. First Configuration The MP.16 system operates with little required setup. However, the administrator must initially configure certain parameters to allow the BS and SS to communicate and (if desired) to secure the network. The following parameters must be set in order for the units to communicate:
Center frequency: On the BS and SS Web interfaces, click Configuration >Radio to set the desired frequency. The following parameters must be set to ensure that the network is secure:
IP address:
On the BS Web interface, click Configuration > Networking > Basic to set the IP address. On the SS Web interface, click Configuration > Network to set the IP address. Passwords: On the BS Web interface, click Commands > Passwords to set HTTPS and CLI passwords. Net Entry mode: On the BS Web interface, click Configuration > SS Authentication to set the Net Entry mode and default SS Class. More information on these parameters as well as more advanced configuration options can be found in following chapters in the Tsunami MP.16 3650 System User Guide:
Base Station Configuration contains information and advanced Web-based configuration options for the BS, including the use of Service Classes. Subscriber Station Configuration contains information and advanced Web-based configuration options for the SS. Command Line Interface contains information on configuring the BS/SS via the CLI. Information for Professional Installers Adjusting Tx Output Power Use the following formula in combination with the table of EIRP limits to calculate system transmit power (based on EIRP limits):
Tx Power Allowed (dBm) = EIRP Limit (dBm) + CL (dB) - G (dB) Where:
Tx Power =
EIRP Limit =
CL =
G =
Output power measured at the antenna input EIRP limits specified below Coax cable loss including loss of connectors Antenna Gain Frequency (GHz) EIRP Limit (dBm) 3.650 - 3.675 38 @ 7 MHz channels 35 @ 3.5 MHz channels Antenna Type Maximum Gain (dBi) Dipole 60 degree sector 90 degree sector 120 degree sector Flat Panel 8 17 14 17 18 Certification Summary Country USA USA Type Base Station Subscriber Station Certification/
Reference Number HZB-MP163650 HZB-MP163650S Technical Support Proxim eService Web Site Support The Proxim eService Web site is available 7x24 at: http://support.proxim.com Telephone Support Contact technical support via telephone as follows:
US and Canada: 408-383-7700, 866-674-6626 (Toll Free) Hours of Operation: 8.00AM-6.00PM, Pacific Time, Monday-Friday APAC Countries: +91 40 23115490 Hours of Operation: 9.00AM-6.00PM, IST (UTC/GMT +5.30 Hrs.), Monday-Friday International: 408-383-7700 Hours of Operation: 8.00AM-6.00PM, Pacific Time, Monday-Friday ServPak Support Advanced Replacement Extended Warranty 7x24 Technical Support Priority Queuing ServPak is a program of Enhanced Service Options that can be purchased individually or in combinations to meet your needs. To learn more, please call Proxim Support at 408-383-7700 or send an email to servpak@proxim.com. To purchase ServPak support services, please contact your authorized Proxim distributor. 1561 Buckeye Drive Milpitas, California 95035 Phone: (408) 383-7600 Fax: (408) 383-7680 www.proxim.com 4 5 6
1 | User Manual | Users Manual | 4.56 MiB | / February 04 2009 |
Tsunami MP.16 3650 System User Guide Software Version 1.0.0 Tsunami MP.16 3650 System User Guide Copyright 2008 Proxim Wireless Corporation. All rights reserved. Covered by one or more of the following U.S. patents: 5,231,634; 5,875,179;
6,006,090; 5,809,060; 6,075,812; 5,077,753. This users guide and the software described in it are copyrighted with all rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form by any means without the written permission of Proxim Wireless Corporation. Trademarks Proxim is a registered trademark, and Tsunami and the Proxim logo are trademarks, of Proxim Wireless Corporation. All other trademarks mentioned herein are the property of their respective owners. Tsunami MP.16 3650 System User Guide Software v. 1.0.0 P/N 76239, Feb 2009 2 Tsunami MP.16 3650 System User Guide Contents 1 Introduction. 8 Products Covered in this User Guide . 8 Document Conventions . 9 Notes, Warnings, Cautions. 9 Acronym List. 9 Product Features. 11 MP.16 System Overview . 13 System Setup . 13 Subscriber Station Initialization, Authentication, and Registration . 13 Wireless Communication and Service Classes . 14 System Monitoring . 14 MP.16 System Management Overview . 15 Web Interface . 15 Command Line Interface . 15 SNMP Management . 15 2 Installation and Initialization . 17 Hardware Description . 18 Base Station Radio . 18 Subscriber Station Radio . 19 Base Station/Subscriber Station LEDs . 19 Power Adaptor . 19 Antennas . 20 Serial Connection . 20 System Requirements . 22 Product Package . 23 Hardware Installation. 25 Step 1: Choose a Location . 27 Step 2: Unpack Shipping Box . 27 Step 3: Assemble the Cable . 28 Step 4: Determine Proper Mounting Orientation. 29 Step 5: Assemble Mounting Hardware . 30 Step 6: Mount the Unit . 31 Step 7: Plug in the Cables . 32 Step 8: Power on the Unit. 33 Step 9: View LEDs . 33 Step 10: Align the Antenna. 34 Step 11: Tighten the Cables . 34 Step 12: Weatherproof the Connectors . 35 Step 13: Install Documentation and Software. 36 3 Tsunami MP.16 3650 System User Guide Using the Web Interface . 37 Logging In . 37 Web Interface Navigation. 38 Installing Latest Software . 39 Download Software . 39 Install Software from your TFTP Server using the Web Interface . 39 Install Software from your TFTP Server using the CLI. 39 First Configuration. 41 3 Base Station Configuration . 42 Introduction . 42 System Configuration . 44 MAC Configuration . 45 Basic MAC Configuration . 45 Advanced MAC Configuration . 46 Radio Configuration . 47 Radio Downlink Burst Profile Configuration . 48 Radio Uplink Burst Profile Configuration. 49 Networking Configuration . 50 Basic Networking . 50 VLANs . 51 Bridging . 55 RADIUS Servers . 57 Syslog . 58 Trap Hosts . 61 Static Routes . 63 Global Positioning System (GPS) . 65 GPS Synchronization . 65 Cable Assembly for GPS Unit . 68 Secondary Management. 70 TFTP Table. 70 DHCP Server . 72 Subscriber Station Authentication . 73 Subscriber Station List . 74 Subscriber Station List Configuration . 75 Service Class Creation . 82 Introduction . 82 Subscriber Station Classes: Overview . 82 Service Class Creation. 85 Logging Configuration. 99 4 Tsunami MP.16 3650 System User Guide Management Interface Configuration . 100 4 Subscriber Station Configuration . 101 System Configuration . 102 Radio Configuration . 103 Network Configuration. 104 Syslog Configuration. 105 Logging Configuration. 106 5 Commands on BS/SS. 107 Update to BS/SS. 108 Update via TFTP . 108 Save Config to Server (BS Only) . 109 Save via TFTP . 109 Reboot . 110 Reset. 111 Passwords. 112 6 Log Messages on the BS/SS . 113 Logging Configuration. 113 Log Messages. 115 Common Log Messages . 115 Base Station Log Messages. 115 Subscriber Station Log Messages . 115 7 Monitoring the BS and SS . 116 Base Station Monitoring . 117 BS Ethernet Statistics. 117 BS MAC Statistics . 117 Service Flow Statistics . 118 Registered SS Statistics. 119 System Inventory . 120 GPS Status. 120 Subscriber Station Monitoring . 121 SS Ethernet Statistics. 121 SS MAC Statistics . 121 SS Service Flow Statistics . 122 A Command Line Interface . 123 CLI Overview. 124 Document Conventions . 124 Basic Functionality . 124 5 Tsunami MP.16 3650 System User Guide CLI Rules . 125 Commands. 126 Configuration from the Base Station . 132 System Parameters . 132 Base Station Parameters . 133 MAC Parameters . 136 Radio Parameters . 136 VLAN ID List. 139 Subscriber Station List . 140 Service Class Creation. 143 Logging Configuration . 153 Trap Host Parameters . 154 Management Interface Parameters . 154 Configuration from the Subscriber Station . 156 Subscriber Station Device Configuration . 156 Radio Configuration . 156 Logging Configuration . 157 Monitoring the BS and SS. 159 Software Version . 159 Network Status (SS only) . 159 Log Messages . 159 Base Station Statistics . 161 Subscriber Station Statistics. 163 B Technical Specifications . 165 Part Numbers . 165 Base Station . 165 Subscriber Station . 165 Base Station Antennas. 165 Subscriber Station Antennas . 165 Power Injector . 165 Accessories/Spare Kits . 166 Product Specifications. 167 Features. 167 Radio Performance . 168 Hardware Specifications . 169 Environmental Specifications . 169 Size and Weight Specifications . 169 Integrated Antenna (SS only). 169 Antenna Port . 170 Data Communication Port . 170 Serial Configuration Port . 170 6 Tsunami MP.16 3650 System User Guide C Technical Services and Support . 171 Obtaining Technical Services and Support . 171 Support Options . 172 Proxim eService Web Site Support . 172 Telephone Support. 172 ServPak Support . 172 D Statement of Warranty . 173 Warranty Coverage . 173 Repair or Replacement . 173 Limitations of Warranty. 173 Support Procedures . 173 Other Information . 174 Search Knowledgebase . 174 Ask a Question or Open an Issue . 174 Other Adapter Cards . 174 7 Introduction Tsunami MP.16 3650 System User Guide 1 Tsunami MP.16 systems consist of one or more Subscriber Stations (SS) that communicate with a Base Station (BS) to provide high-performance wireless network connections. There are no DSL, cable, or leased-line contracts to negotiate. Easy installation and operation allow network planners to quickly deploy up to 26 Mbps capacity between locations, making it the ideal solution for:
Establishing high-speed connections between Internet Service Providers and their customers Organizations requiring high-capacity WAN connectivity between multiple buildings or campuses Organizations or service providers seeking network redundancy for mission-critical wired connections See the following sections for more information:
Products Covered in this User Guide Document Conventions Notes, Warnings, Cautions Acronym List Product Features MP.16 System Overview System Setup Subscriber Station Initialization, Authentication, and Registration Wireless Communication and Service Classes System Monitoring MP.16 System Management Overview Web Interface Command Line Interface SNMP Management Products Covered in this User Guide This guide details functionality of the Tsunami MP.16 3650 System, consisting of the following:
Product Description Tsunami MP.16 3650 Base Station Tsunami MP.16 3650 Base Station with external type-N antenna connector Tsunami MP.16 3650 Subscriber Station Tsunami MP.16 3650i Subscriber Station Tsunami MP.16 3650 Subscriber Station with integrated antenna Tsunami MP.16 3650 Subscriber Station with external type-N antenna connector 8 Introduction Document Conventions Document Conventions Notes, Warnings, Cautions The following special notations are used:
Tsunami MP.16 3650 System User Guide NOTE: A note contains important information that helps you make better use of the AP or your computer. CAUTION: A Caution indicates potential damage to hardware or loss of data. WARNING: A Warning indicates imminent danger to hardware or loss of data. Acronym List This document contains the following acronyms:
Acronym Definition AK ARQ AWG BE BPSK BS CAT5 CID CINR CIR CLI CRC DCD DL FEC GPS GUI HCS HTTP ICMP IEEE IP IP TOS LOS MAC MIR Authorization Key Automatic Retransmission Request American Wire Gauge Best Effort Bi-Phase Shift Keying Base Station Category 5 Connection ID Carrier to Interference Noise Ratio CIR Committed Information Rate; equivalent to "Minimum Reserved Traffic Rate" defined in IEEE 802.16-2004 specification Command Line Interface Cyclic Redundancy Check Downlink Channel Descriptor Downlink Forward Error Correction Global Positioning System Graphical User Interface Header Check Sequence Hyper Text Transfer Protocol Internet Control Message Protocol Institute of Electrical and Electronics Engineers Internet Protocol Internet Protocol Type of Service Line of Sight Media Access Control MIR Maximum Information Rate; equivalent to "Maximum Sustained Traffic Rate" defined in IEEE 802.16-2004 specification. 9 Introduction Document Conventions Acronym Tsunami MP.16 3650 System User Guide Definition NLOS nrtPS OFDM PDU PIR PoE PPPoE QAM QoS QPSK RADIUS RSNR RSSI rtPS Rx SDU SF SF Class SFID SLA SNR SS SS Class TDD TEK TFTP Tx UCD UGS UL VLAN VoIP WAN Non Line of Sight Non-Real-Time Polling Services Orthogonal Frequency Division Modulation Protocol Data Unit Packet Identification Rule Power over Ethernet Point to Point Protocol over Ethernet Quadrature Amplitude Modulation Quality of Service Quadrature Phase Shift Keying Remote Authentication Dial-In User Service Received Signal to Noise Ratio Receive Signal Strength Indicator Real-Time Polling Services Receive Service Data Units Service Flow Service Flow Class Service Flow ID Service Level Agreement Signal to Noise Ratio Subscriber Station Subscriber Station Class Time Division Duplex Traffic Encryption Key Trivial File Transfer Protocol. Transmit Uplink Channel Descriptor Unsolicited Grant Service Uplink Virtual Local Area Network Voice over IP Wide Area Network 10 Introduction Product Features Product Features Tsunami MP.16 3650 System User Guide Based on 802.16-2004 standard WiMAX Forum certified Licensed 3.65 - 3.675 GHz bands for worldwide operation Support for both 3.5 MHz and 7 MHz channel bandwidths Time Division Duplex operation Modulation modes: BS operation in any combination of the following modulation parameters: BPSK-1/2, QPSK-1/2, QPSK-3/4, 16QAM-1/2, 16QAM-3/4, 64QAM-2/3, and 64QAM-3/4 Cyclic prefix: Tb/32, Tb/16, Tb/8, and Tb/4 FEC: concatenated, Reed-Solomon Convolutional Coding (RS-CC) only Frame duration (BS/SS): 5, 10, and 20 ms Up to approximately 10 Mbps in 3.5 MHz bandwidth 20 km LOS range with standard antennas All outdoor units with integrated antenna for simple installation Bridge and VLAN networking modes Local and remote network management through SNMP, HTTP (Web), or Command Line Interface Maximum coverage with OFDM for NLOS coverage Fast and reliable installation of Subscriber Station equipment at the end users site to minimize the installation cost Extensive performance monitoring and fault diagnostics from the Base Station to minimize truck rolls to the end-users premises Low latency for VoIP services, and QoS to manage VoIP connections Bandwidth management to multiple service level agreements (SLAs) Capability to operate co-located Base Stations in a multi-sectored deployment Centralized provisioning and management of Subscriber Stations through Base Station Support for VLAN tagging and filtering (IEEE 802.1q) Uplink/downlink boundary configuration (BS) Adaptive modulation Two access control levels with password (Admin/User) Creation and maintenance of Subscriber Station service profiles (BS) Up to 256 Service Flow Classes (BS) Up to 512 Packet Identification Rules (BS) Up to 64 Subscriber Station classes (BS) Subscriber Station configuration and service provisioning (BS) Scheduling (UGS and BE) (BS) Ethernet packet lengths from 64 to 1600 bytes PPPoE transparent mode Database for up to 512 configurable Subscriber Stations (BS) RADIUS authentication (BS) MIR, drop ingress packets in excess of "maximum sustained traffic rate" per connection CIR, schedule non-BE traffic to maintain to a "minimum reserved traffic rate" per connection Antenna alignment tool Performance monitoring via CLI and Web-GUI Configuration import/export utility 11 Introduction Product Features Tsunami MP.16 3650 System User Guide Statistics Ethernet connection LED indicators GPS LED Indicator (BS) SS management via Ethernet Power-on self test Continuous built-in self test Over-the-air and Ethernet software image upgrades via Web and CLI Revert to default configuration Software reset 12 Introduction MP.16 System Overview MP.16 System Overview Tsunami MP.16 3650 System User Guide In the MP.16 system, a Base Station (BS) communicates and exchanges traffic with one or more Subscriber Stations
(SS). System implementation is streamlined, requiring initial setup on the Base Station of Base-Station-specific, system-wide, and select Subscriber Station parameters, but requiring only minimal configuration on individual Subscriber Stations themselves. This centralized configuration procedure allows for more efficient deployment of MP.16 systems. The processes involved in the MP.16 system setup and functionality are described in the following sections:
System Setup Subscriber Station Initialization, Authentication, and Registration Wireless Communication and Service Classes System Monitoring System Setup The administrator configures local BS and system-level options by using one of the BSs management interfaces (HTTP, CLI, or SNMP). Configuration from the BS includes the following:
System: Configure local BS information, such as the system name, location, up time, and the contact persons email and phone number. MAC: Configure basic and advanced MAC parameters, including frame duration; downlink percentage; frame synchronization mode; DCD, UCD, and initial ranging intervals; and TEK lifetime. Radio: Select the BSs operating channel and configure downlink/uplink burst profiles. Networking: Configure the BSs Ethernet address/mask, transmission speed, static routes, and VLANs, and external
(RADIUS) servers. Subscriber Station Authentication: Set the Net Entry mode (authorization level for SSs entering the network), and choose a default Subscriber Station Class that will be assigned to all SSs entering the network without a pre-assigned class. Subscriber Station List: Add Subscriber Stations to the Base Stations list of registered SSs, or view the list of registered SSs. Assign SS Classes to individual Subscriber Stations; override SS Class parameters on a per-SS basis. Service Class Creation: Create new Packet Identification Rules (PIRs), Service Flows (SFs), and Subscriber Station Classes (SS Classes), or view and modify existing PIRs, SFs, and SS classes. Log: Set the parameters for the logging functions of the BS. BS configuration parameters are discussed in their entirety in Base Station Configuration. Subscriber Station Initialization, Authentication, and Registration When a Subscriber Station is initialized, it uses the configured frequency channels to search for a Base Station. If it finds one, it synchronizes with the BS to determine initial timing, frequency, and power settings. Once these settings are established, the SS attempts to register with the network. To do so, the SS sends the BS an Authentication Information message followed by an Authentication Request message. The BS verifies that the SS is authorized to join the network and sends an authorization response containing an Authorization Key (AK) encrypted with the SSs public key. This AK is used to secure the transmission of traffic encryption keys (TEKs), which secure further transmissions between the SS and BS. Periodically, the SS is required to reauthenticate and refresh its key information. The SS then sends the BS information about the SSs capabilities and operational parameters. The BS begins initiating Service Flows (see Wireless Communication and Service Classes). Once a Service Flow is active, a connection is established. The BS sets up uplink and downlink connections to carry traffic between the SS and BS. Much of the SSs configuration is set by the BS; that is, the administrator configures SS parameters on the BS, and the BS provisions this configuration information to the SS when it registers with the BS. However, an administrator can 13 Introduction MP.16 System Overview Tsunami MP.16 3650 System User Guide configure Subscriber Station parameters locally on the SS by using one of the SSs management interfaces (HTTP, CLI, or SNMP). Configuration from the SS includes the following:
SS: Configure local SS information, such as the system name, location, up time, and the contact persons email and phone number. Radio: Select the SSs operating channel, channel bandwidth, and optionally configure a connection with a specific BS. Networking: Configure the SSs Ethernet address/mask and default gateway. Log: Set the parameters for the logging functions of the SS. SS configuration parameters are discussed in their entirety in Subscriber Station Configuration. Wireless Communication and Service Classes Traffic is exchanged between the BS and SS through uplink connections (SS to BS) and downlink connections (BS to SS). The MP.16 system supports Time Division Duplex (TDD) operation. In TDD operation, wireless transmissions are divided into fixed-duration frames, with uplink and downlink subframes making up each frame. In order to allow the administrator to efficiently define connections and their associated traffic types and QoS parameters, the BS uses defined classes of service, called Subscriber Station Classes (SS Classes). SS Classes, configured on the BS and provisioned to SSs in the network, determine how different types of traffic are handled. As a packet is transmitted between the BS and SS, it is compared to a defined set of Packet Identification Rules. Each rule contains classifiers against which the packet is matched; depending on which classifiers the packet matches, it is directed to a particular uplink or downlink Service Flow. The Service Flow determines the QoS treatment for each packet. Each SS Class contains at least one uplink and one downlink Service Flow (but as many as 16), each with associated QoS settings. Up to 64 SS Classes can be created. By using multiple SS Classes that include different SFs, a service provider can offer tiers of service to customers. A premium plan, for instance, may consist of SS Classes offering SFs with improved QoS over a standard or basic plan. The MP.16 system comes supplied with pre-defined SS Classes, Service Flows, and PIRs. In addition, you can customize the predefined SS Classes, Service Flows, and PIRs or create new ones that uniquely serve the needs of your network environment. Upon entering the network, an SS uses either the default SS class configured on the BS (under the Subscriber Station Authentication tab) or a pre-assigned SS class (assigned by the BS under the Subscriber Station List tab or by a configured RADIUS server). See Service Class Creation for information on defining custom SS classes. System Monitoring Interface statistics Administrators and authorized users can monitor the following system statistics. Log messages MAC statistics Service Flow statistics SS Statistics (BS only) See Log Messages on the BS/SS. 14 Introduction MP.16 System Management Overview MP.16 System Management Overview Tsunami MP.16 3650 System User Guide The MP.16 system offers two levels of management access:
Administrators can display or change configuration settings, and can display configuration settings, logs, and statistics. Users can display configuration settings, logs, and statistics. The following management interfaces are available:
Web Interface Command Line Interface SNMP Management Web Interface The Web interface (HTTP) provides easy access to configuration settings and network statistics from any computer on the network. You can access the Web interface over your network, over the Internet, or with a crossover Ethernet cable connected directly to your computers Ethernet port. See Using the Web Interface for instructions and the following chapters for configuration and monitoring information:
Base Station Configuration Subscriber Station Configuration Commands on BS/SS Log Messages on the BS/SS Monitoring the BS and SS Command Line Interface The Command Line Interface (CLI) is a text-based configuration utility that supports a set of keyboard commands and parameters to configure and manage the MP.16 system. An administrator enters command statements, composed of CLI commands and their associated parameters. Statements may be issued from the keyboard for real time control, or from scripts that automate configuration. The CLI can be accessed through a terminal emulator over a serial connection or via Telnet. See Command Line Interface for more information on the CLI and for a list of CLI commands and parameters. SNMP Management In addition to the Web interface and the CLI, you also can manage and configure your unit using the Simple Network Management Protocol (SNMP). Note that this requires an SNMP manager program (sometimes called MIB browser) or a Network Manager program using SNMP, such as HP OpenView or Castle Rocks SNMPc. The units support several Management Information Base (MIB) files that describe the parameters that can be viewed and configured using SNMP:
ProximTmp16.mib WMAN-IF-MIB.mib MIB files are provided on the CD included with your unit. You must compile one or more of these MIB files into your SNMP programs database before you can manage your unit using SNMP. These MIBs define the read and read/write objects you can view or configure using SNMP. These objects correspond to most of the settings and statistics that are available with the other management interfaces. The MIB can be opened with any text editor, such as Microsoft Word, Notepad, and WordPad. NOTE: When you update the software in the unit, you must also update the MIBs to the same release. Because the parameters in the MIB may have changed, you may not have full control over the features in the new release. 15 Introduction MP.16 System Management Overview Tsunami MP.16 3650 System User Guide See the documentation that came with your SNMP manager for instructions about how to compile MIBs. The remainder of the User Guide discusses installing your MP.16 system and managing it using the Web and CLI interfaces. IMPORTANT!
16 Installation and Initialization Tsunami MP.16 3650 System User Guide 2 Hardware Description Base Station Radio Subscriber Station Radio Base Station/Subscriber Station LEDs Power Adaptor Antennas Serial Connection System Requirements Product Package Hardware Installation Step 1: Choose a Location Step 2: Unpack Shipping Box Step 3: Assemble the Cable Step 4: Determine Proper Mounting Orientation Step 5: Assemble Mounting Hardware Step 6: Mount the Unit Step 7: Plug in the Cables Step 8: Power on the Unit Step 9: View LEDs Step 10: Align the Antenna Step 11: Tighten the Cables Step 12: Weatherproof the Connectors Step 13: Install Documentation and Software Using the Web Interface Logging In Web Interface Navigation Installing Latest Software First Configuration 17 Installation and Initialization Hardware Description Hardware Description Tsunami MP.16 3650 System User Guide The BS and SS equipment consists of a radio, power adaptor, and external antenna connectors (on some SS models). See Product Package for a full list of included components. The BS radio provides a wireless link between an Ethernet connection and SSs registered to the BS. It is installed outdoors in close proximity to its antenna so that the RF cable connection to the antenna has minimal loss. The power adaptor powers the BS over the PoE CAT5 cable. It also provides an Ethernet connection with the same PoE CAT5 cable, and the power adaptors second RJ45 connector connects the 100Base-T data signals to the backhaul network. The BS comes with a Type-N connector to attach external antennas. A single omni-directional antenna or multiple sector antennas (in combination with additional BSs) may be used to provide 360 degrees of coverage. The SS radio provides a wireless non-line-of-site connection with the BS. A CAT5 cable connects the SS to the users switch/router through the power adaptor to provide DC power to the radio and 100/10Base-T Ethernet service between the radio and a switch/router. This data port can be connected to either a single Ethernet host or to an Ethernet switch so that the SS can address multiple Ethernet hosts. The SS comes with an integrated panel antenna or a Type-N antenna connector to enable the use of external antennas. External antennas may be used to provide greater range. See the following:
Base Station Radio Subscriber Station Radio Base Station/Subscriber Station LEDs Power Adaptor Antennas Serial Connection Base Station Radio The BS radio operates in one of 744 possible frequency channels set by the user in the licensed 3.65 - 3.675 GHz bands, and time duplexes between transmitting downlink bursts to SSs and receiving uplink bursts from SSs. The major functions of the BS radio include:
Signal Radiation/Reception: An external antenna receives downlink and radiates uplink RF signals. Upconversion/Downconversion: Received RF signals are amplified and downconverted to baseband for demodulation; modulated uplink signals from baseband to RF are upconverted and amplified to a controlled power level. Modulation/Demodulation: Downlink MAC protocol data units (PDUs) are Forward Error Correction (FEC) encoded and modulate the baseband downlink. Uplink bursts received from SSs are demodulated and FEC decoded into MAC PDUs. The demodulation function also includes carrier-frequency, symbol-timing synchronization, and channel equalization. Wireless MAC Functions: Control and traffic data from the Ethernet services are formatted into MAC PDUs and assembled into downlink bursts. Uplink bursts received from SSs are parsed into MAC control messages and traffic SDUs destined for the Ethernet service. The MAC also controls frame synchronization, SS network entry, SS ranging and power control, bandwidth requests, QoS scheduling, encryption, and key management. Network Services: Services to connect a 10/100Base-T Ethernet interface to the wireless network include the following capabilities: bridging, VLAN awareness, ICMP, and PPPoE. BS Management: Configuration and dynamic control of the BS are provided via a command line interface (CLI), an HTTP GUI, and SNMP. Performance and status data can be displayed to enable a local or remote operator to determine the operational status, usage, and link performance of the BS and its active SSs. 18 Installation and Initialization Hardware Description Subscriber Station Radio Tsunami MP.16 3650 System User Guide The SS radio operates in one of 744 possible frequency channels set by the user in the licensed 3.65 - 3.675 GHz bands, and time duplexes between receiving downlink bursts from the BS and transmitting uplink bursts to the BS. The major functions of the SS radio include:
Signal Radiation/Reception: An integrated or external antenna receives downlink and radiates uplink RF signals. Upconversion/Downconversion: Received downlink RF signals are amplified and downconverted to baseband for demodulation; modulated uplink signals from baseband to RF are upconverted and amplified to a controlled power level. Modulation/Demodulation: Received baseband signals are demodulated and FEC decoded into MAC protocol data units (PDUs). Uplink PDUs are FEC encoded and modulate the baseband uplink. The demodulation function also includes carrier-frequency, symbol-timing synchronization, and channel equalization. Wireless MAC Functions: Control and traffic messages destined for Ethernet hosts and TDM interfaces connected to the SS are parsed from downlink MAC PDUs. Uplink PDUs are constructed to transport control and traffic data from Ethernet hosts and TDM interfaces. The MAC also controls uplink synchronization, power control, network entry, bandwidth requests, QoS scheduling, encryption, and key management. Network Services: Services to connect a 10/100Base-T Ethernet interface to the wireless network include the following capabilities: bridging, VLAN awareness, ICMP, and PPPoE. SS Management: Configuration and dynamic control of the SS are provided via the BS, a command-line interface
(CLI), an HTTP GUI, and SNMP. Performance and status data can be displayed to enable a local or remote operator to determine the operational status, usage, and link performance of the SS. Status and performance information is also sent to the BS as requested. Base Station/Subscriber Station LEDs Two LED indicators are available on the Ethernet port of the BS and SS. These LEDs display the activity of the Ethernet and RF links. If a water-tight cap is installed with the unit, you will need to unscrew it to view the LEDs. Ethernet LED RF LED Figure 2-1 BS/SS LED Indicators Power Adaptor The power adaptor provides Power-over-Ethernet (PoE), supplying electricity and wired connectivity to the unit over a single 24 AWG CAT5 (diameter .114 to .250 inches/2.9 to 6.4 mm). The unit is not 802.3af-compatible. Always use the supplied power injector to ensure that the unit is powered properly. Note that the Active Ethernet module provides +48 VDC over a standard CAT5 Ethernet cable. Depressing the power adaptors Reload button for five seconds during power-up remotely resets BS/SS parameters affecting communication between the BS and SS to their factory default settings: IP address, subnet mask, user name, password, Ethernet speed/duplex, and VLAN mode. 19 Installation and Initialization Hardware Description Power Adaptor LED Tsunami MP.16 3650 System User Guide An LED is provided on top of the power adaptor, as shown in the following figure. Figure 2-2 Power Adaptor LEDs When the LED is green, the power is on. Antennas Some Tsunami MP.16 3650 units have integrated antennas, while others have external antenna connectors (Type-N) and no integrated antennas. External connector specifications are as follows:
Characteristic Limit Connector type Impedance Antenna Return Loss DC Resistance Type-N, female 50 Ohms over the operating frequency band
-10 dB maximum DC resistance to ground less than 1 Ohm For more information on external antennas, see the Tsunami MP.16 3650 System Antenna Installation Guide and the Tsunami MP.16 System Recommended Antennas guide. Serial Connection The serial connection is used for issuing CLI commands using a terminal emulator. The serial connection is made with an RJ45 to DB9 connector (also referred to as a dongle). During Hardware Installation, plug the RJ45 end of the dongle into the GPS/SYNC port of the radio and connect the serial end to your PC. The serial dongle also includes an in-line stereo jack to aid in antenna alignment (upcoming feature). Connections are as follows:
DB9 In-Line RJ45 Plug Stereo Jack NC NC NC NC Connector NC 5 5 2 1 2 3 4 20 Tsunami MP.16 3650 System User Guide Installation and Initialization Hardware Description RJ45 Plug In-Line Stereo Jack NC 1 2, 3 NC DB9 Connector 3 5 NC NC 5 6 6 8 21 Installation and Initialization System Requirements System Requirements Tsunami MP.16 3650 System User Guide A 10Base-T Ethernet or 100Base-TX Fast Ethernet switch or hub or cross-over Ethernet cable A computer that is connected to the same IP network and has one of the following Web browsers installed:
Microsoft Internet Explorer 6 Mozilla Firefox 1.5 22 Installation and Initialization Product Package Product Package Tsunami MP.16 3650 System User Guide Each Tsunami MP.16 shipment includes the items in the following table. Verify that you have received all parts of the shipment. NOTE: Cables are not supplied with the unit. One of the following:
BS / SS with external antenna connector SS with Integrated Antenna RJ45 to DB9 serial connector
(supplied with BS only) (1 ea.) Installation CD (1 ea.) Power Adaptor and Cord (1 ea.) Cable Termination Kit Kit includes the following:
a b c d e a. RJ45 connector b. Sealing cap c. Sealing nut d. Lock nut e. Grounding screws 23 Installation and Initialization Product Package Tsunami MP.16 3650 System User Guide Mounting Kit Kit includes the following:
a b c a. Mounting clamp for wall/pole b. Extension arm c. Mounting plate to enclosure d. Mounting clamp for pole mounting d Mounting Hardware The following mounting hardware, included with the mounting kit:
Quantity Description 6 ea. Plain washer #5/16 2 ea. Hex Cap Screw NC 5/16-18 x 35 2 ea. 4 ea. 4 ea. 2 ea. 4 ea. Nut NC 5/16-18 Helical Spring Lock Washer #1/4 Helical Spring Lock Washer #1/16 Hex Cap Screw NC 5/16-18 x 80 68764, Screw, Machine, Pan, Philips, 1/4"-20, 5/8"L Rubber Tape Strip 24 Installation and Initialization Hardware Installation Hardware Installation Tsunami MP.16 3650 System User Guide This section describes the steps required to install and mount the unit, and to align the antenna. The installation procedure does not include the mounting and connection of antennas. See the documentation the accompanies the antenna and the Tsunami MP.16 3650 System Antenna Installation Guide for this information. IMPORTANT:
Before installing and using this product, see Safety and Regulatory Compliance Information on the product CD. IMPORTANT:
All units must be installed by a suitably trained professional installation technician or by a qualified installation service. WARNING:
To ensure proper grounding, use the hole at the bottom point on the back of each unit and the provided grounding screws to attach a ground wire of at least 10 AWG stranded to each unit. Use proper wire grounding techniques in accordance with local electric codes. NOTE: Be sure to read the Release Notes file on the product CD as it contains software version and driver information that may not have been available when this document was produced. NOTE: Equipment is to be used with, and powered by, the power injector provided or by a power injector that meets Limited Power Source Output per UL/IEC 60950 these requirements:
UL-Listed/ITE (NWGQ) CE-marked Rated output, 48 Vdc/0.67 A Approved for Power-over-Ethernet Pinout follows 802.3af standard for mid-span devices See the following sections for installation instructions:
Step 1: Choose a Location Step 2: Unpack Shipping Box Step 3: Assemble the Cable Step 4: Determine Proper Mounting Orientation Step 5: Assemble Mounting Hardware Step 6: Mount the Unit Step 7: Plug in the Cables Step 8: Power on the Unit Step 9: View LEDs Step 10: Align the Antenna Step 11: Tighten the Cables 25 Installation and Initialization Hardware Installation Step 12: Weatherproof the Connectors Step 13: Install Documentation and Software Tsunami MP.16 3650 System User Guide 26 Installation and Initialization Hardware Installation Step 1: Choose a Location Tsunami MP.16 3650 System User Guide To make optimal use of the unit, you must find a suitable location for the hardware. The range of the radio unit largely depends upon the position of the antenna. Proxim recommends you do a site survey, observing the following requirements, before mounting the hardware. The location must allow easy disconnection of power to the radio if necessary. Air must be able to flow freely around the hardware. The radio unit must be kept away from vibration and excessive heat. The installation must conform to local regulations at all times. The units are designed to directly mount to a pole or wall. Using the supplied brackets and hardware, you can mount them to a 1.25 inch to 4.5-inch pole (outside diameter). Using just one of the pole mounting brackets, you can mount the units to a wall or other flat surface. CAUTION: Proxim recommends the use of a lightning arrestor at the building ingress point. You can purchase the Proxim Lightning Protector; see the documentation that comes with the Lightning Protector for more information and installation instructions. Step 2: Unpack Shipping Box 1. Unpack the unit and accessories from the shipping box. 2. Note the Ethernet and MAC addresses of the unit, as well as the serial number. The addresses may be used when configuring the unit. The serial number is required to obtain support from Proxim. Keep this information in a safe place. 27 Installation and Initialization Hardware Installation Step 3: Assemble the Cable Tsunami MP.16 3650 System User Guide You will be attaching an outdoor-rated 24 AWG CAT5 cable (diameter .114 to .250 inches/2.9 to 6.4 mm) (not provided) to the Power-over-Ethernet port on the back of the unit and waterproofing the assembly later in the installation procedure. First, you must construct the cable and assemble the waterproofing cable covers as described in the following steps. Proxim greatly simplifies this assembly process by offering pre-assembled CAT5 cable kits in 25m, 50m, and 75m lengths
(part numbers 69819, 69820, and 69821, respectively). 1. Slide the sealing nut (A) over the bare end of the CAT5 cable. 2. Slide the lock nut (B) over the bare end of the CAT5 cable. 3. Slide the sealing cap (C) over the bare end of the CAT5 cable. Make sure the red rubber gasket is inside the cap. 4. Apply two wraps of 0.5 wide Teflon tape (not supplied with unit) around the threads of the lock nut (B) that will go inside the sealing cap. 5. Thread the lock nut (B) onto the sealing cap (C), and hand tighten. 6. Terminate the RJ45 connectors (D) to both ends of the CAT5 cable; test for proper wiring (cable should be a straight-through cable). D C B Apply Teflon tape here A NOTE:
The cable must feed through all parts of the weatherproof cap before the RJ45 is crimped on the outdoor Ethernet cable. The cable between the power injector and the unit must be a straight-through Ethernet cable (without crossover). Due to variance in CAT5 cable diameter, termination techniques of the installer, and the application of proper tightness of the connectors, it is strongly recommended that all cable connectors are secured by external weatherproofing. This process will be described in Step 12: Weatherproof the Connectors. 28 Installation and Initialization Hardware Installation Step 4: Determine Proper Mounting Orientation Tsunami MP.16 3650 System User Guide 1. Locate the arrow on the back of the unit and determine your desired mounting orientation. For vertical polarization using the integrated antenna, the arrow should be pointing up (perpendicular to the ground). For horizontal polarization using the integral antenna, the arrow should be horizontal (parallel to the ground). Vertical Polarization Horizontal Polarization 29 Installation and Initialization Hardware Installation Step 5: Assemble Mounting Hardware Tsunami MP.16 3650 System User Guide 1. Attach the mounting plate (A) using the provided screws and washers (Torque 9 N.m/75 in-lbs), such that the units antenna will be vertically or horizontally polarized when mounted. A Torque 9 N.m/75 in-lbs 2. Attach the extension arm (B) to mounting piece (A) with the screw, nut, and washers provided, as shown below. The extension arm gives the unit more possible tilt, letting you adjust for azimuth or elevation over a larger angle. A B 3. Attach the mounting bracket (C) to extension arm (B) with the screw, nut, and washers provided. C B 4. Tighten assembly (Torque 15 N.m/130 in-lbs). Torque 15 N.m/130 in-lbs 30 Installation and Initialization Hardware Installation The following figure shows the full assembly attached to the unit:
Tsunami MP.16 3650 System User Guide Step 6: Mount the Unit 1. To pole-mount, insert the provided screws through bracket F. Fasten around the pole to bracket E and secure (Torque 11 N.m/100 in-lbs). F F E Torque 11 N.m/100 in-lbs 2 screws 2. To wall-mount the unit, mount bracket E to the wall using 4 screws (not provided), as shown:
31 Installation and Initialization Hardware Installation Step 7: Plug in the Cables 1. Plug one end of the CAT5 cable (A) into the RJ45 jack of the unit (B). Tsunami MP.16 3650 System User Guide A B 2. Connect the free end of the CAT5 cable to the Data and Power Out port on the power injector. 3. To connect the unit through a hub or a switch to a PC, connect a straight-through Ethernet cable between the network interface card in the PC and the hub, and between the hub and the RJ45 Data In port on the PoE adapter. To connect the unit directly to a PC, connect a cross-over Ethernet cable between the network interface card in the PC and the RJ45 Data In port on the power injector. 32 Installation and Initialization Hardware Installation Step 8: Power on the Unit Tsunami MP.16 3650 System User Guide Once you have connected the power injector to the Ethernet cabling and plugged the power injector cord into an AC outlet, the unit is powered on. There is no ON/OFF switch on the unit. To remove power, unplug the AC cord from the AC outlet or disconnect the RJ45 connector from the Data and Power Out port on the power injector. Step 9: View LEDs When the unit is powered on, it performs startup diagnostics. When startup is complete, the LEDs show the units operational state. The LEDs are present at the units Ethernet connector. Ethernet LED RF LED LEDs exhibit the following behavior:
LED State Ethernet LED RF (Wireless) LED Off On (solid green) No Ethernet link. Ethernet link is connected. Flashing Packets are being received on Ethernet. Base Station Subscriber Station Radio is off. Radio is active (transmitting downlink and receiving uplink). Unit is in standby. Radio is off. Downlink synchronized. Increasing on-off speed indicates an increasing RSNR. 33 Installation and Initialization Hardware Installation Step 10: Align the Antenna Tsunami MP.16 3650 System User Guide Antenna alignment is the process of physically aligning the antenna of the radio receiver and transmitter to have the best possible link established between them. The antenna alignment process is usually performed during installation and after major repairs. If you are installing external antennas, consult the documentation that accompanies the antenna for installation instructions. Note that you must weatherproof the antenna connectors as described in Step 12: Weatherproof the Connectors. To ensure correct antenna alignment:
1. Perform a link budget calculation. 2. Compare the calculation to the SNR value on the SS by logging into the SS Web interface and clicking Monitor >
Statistics > MAC Statistics. If needed, physically adjust the antenna, and refresh the Monitor > Statistics > MAC Statistics page to take a new reading. 3. Step 11: Tighten the Cables 1. Apply two wraps of Teflon tape around the threads of the units RJ45 jack (A) in a clockwise direction. 2. Make sure that the red rubber gasket is still seated in the sealing cap of the sealing cap/lock nut assembly (B);
3. Slide the sealing cap/lock nut assembly (B) over the RJ45 jack (A) and thread onto enclosure. Hand tighten first, then use a pipe wrench or similar tool to tighten one more quarter turn. CAUTION: Do not over-tighten!
4. Tighten the lock nut (C) (Torque 4 N.m/35 in-lbs). 5. Thread the sealing nut (D) onto the sealing cap/lock nut assembly (B) and tighten (Torque 3 N.m/25 in-lbs). CAUTION: The lock nut (C) on the sealing cap/lock nut assembly (B) must be fully tightened over the RJ45 connector before the sealing nut (D) is fully tightened. Otherwise, the Ethernet cable may twist and damage. B D C A (Apply Teflon tape here) Torque 4 N.m/35 in-lbs Torque 3 N.m/25 in-lbs 34 Installation and Initialization Hardware Installation Step 12: Weatherproof the Connectors Tsunami MP.16 3650 System User Guide After you have fully assembled and tightened the cable, use the provided self-fusing, rubber-based tape strip and electrical tape (not provided; Proxim recommends Scotch Super 33+ Vinyl Electrical Tape) to seal the connection, as follows. 1. Remove the film liner from the rubber-based tape strip, and stretch the tape until it is approximately half of its original width. This activates the self-fusing action of the tape, which will set up over time to create a single, waterproof mass. 2. Stretch and wrap the tape around the connector tightly, starting below the connector cap and against the unit and wrapping in a clockwise direction. Wrap the tape once around the base of the connector cap (A). Continue to wrap the tape spirally around the connector in a clockwise direction, maintaining a 50% width overlap (B). Continue wrapping the tape spirally upward (C) until the tape extends onto the cable and you have used the entire length of tape. Seal the tape tightly against the connector and the cable (D). NOTE: Be sure to wrap the tape in a clockwise direction; wrapping the tape in a counterclockwise direction may loosen up the connector. A B C D Start below connector cap Continue onto cable 3. In the same manner as described in Step 2 above, apply a layer of black electrical tape (not provided) over the rubber-based tape for further protection. Make sure the electrical tape also extends beyond the rubber-based tape to seal it. 4. Repeat the weatherproofing procedure for other connectors as appropriate. 35 Installation and Initialization Hardware Installation Step 13: Install Documentation and Software Tsunami MP.16 3650 System User Guide To install the documentation and software on a computer or network:
1. Place the installation CD in a CD-ROM drive. The installer normally starts automatically. (If the installation program does not start automatically, double click setup.exe on the installation CD.) 2. The following documentation and software products are installed:
Available from Start > All Programs > Tsunami > MP.16 3650:
Documentation (in Docs subdirectory):
User Guide Quick Installation Guide Recommended Antenna Guide Safety and Regulatory Guide Antenna Installation Guide MP.16 3650 Online Help NOTE: All of these items are also available from C:\Program Files\Tsunami\MP.16 3650. Available from C:\Program Files\Tsunami\MP.16 3650:
Documentation (in Docs folder): See list above Help files (in Help folder; click on index.htm to access) MIB files (in MIBs folder) TFTP Server (in Extras folder) 36 Installation and Initialization Using the Web Interface Using the Web Interface Logging In Tsunami MP.16 3650 System User Guide You may use your web browser to monitor and configure the radio unit. To configure and monitor the unit using the command line interface, see Command Line Interface. 1. Open a Web browser on a network computer. 2. Enter the units IP address in the browsers Address field and press Enter or Go. The default IP address of the BS is 192.168.10.1. The default IP address of the SS is 192.168.10.2. NOTE: The unit must be on the same subnet as your network computer. The default subnet for the BS is 255.255.254.0; the default for the SS is 255.255.255.0. The login page is displayed. Figure 2-3 Enter Network Password 3. Log in as follows:
To log in as an administrator, enter admin in the User Name field. Enter the password in the Password field. For new units, the default administrator password is public. To log in as a user, enter user in the User Name field. Enter the password in the Password field. For new units, the default password is public. NOTE: To change passwords via the web interface, see Passwords in the Commands on BS/SS chapter. To change passwords through the CLI, see Passwd Command in the Command Line Interface chapter. Upon successful login, the System Overview page is displayed, containing read-only information about your BS or SS. Figure 2-4 System Overview Page (Base Station) You can configure many of the parameters displayed on this page from the System Configuration page. To return to this page at any time, click MP.16 BS (Admin Logon) or MP.16 SS (Admin Logon) on the menu. 37 Installation and Initialization Using the Web Interface Tsunami MP.16 3650 System User Guide 4. Click on any of the menu items on the left side of the screen to begin configuring the unit. Web Interface Navigation The Web interface screen contains two sections (see Figure 2-5):
Menu: Use the collapsible menu on the left of your screen to navigate through the web interface. For headings
) click on the arrow to the left of the heading to expand its contents (
). Configuration
(marked with a folder icon:
pages (marked with a page icon:
NOTE: You must click on an item with a page icon (
) are used for configuring the unit. expanded heading (
), the screen will not update.
) to display configuration parameters; if you click on an Configuration parameters: View and change the units settings in the work area. Enter required or desired values in available fields, or use drop down menus to make selections. When you have configured a page, you must click the OK button to save your changes. If you do not click the OK button, the configuration parameters you specified will not be set. Configuration/Monitoring parameters Menu Figure 2-5 Web Interface Screen (Base Station) 38 Installation and Initialization Installing Latest Software Installing Latest Software Tsunami MP.16 3650 System User Guide Proxim periodically releases updated software for the Tsunami MP.16 3650 system on its support Web site, http://support.proxim.com. Proxim recommends that you check the Web site for the latest updates after you have installed and initialized the unit. Download Software 1. Contact Technical Services and Support to obtain the newest software. 2. Store the downloaded software in your TFTP servers directory. 3. Install the software via TFTP using the Web interface or the Command Line Interface, as described below. Install Software from your TFTP Server using the Web Interface 1. Log in to the BS or SS 2. Click Commands > Update to BS or Update to SS > via TFTP The Update Via TFTP page is displayed, as shown below. Figure 2-6 Update via TFTP Screen 3. From the File Type drop-down menu, select Image. 4. Enter the name of the downloaded software file (including the file extension) in the TFTP File Name field. This file must be in the TFTP servers local root directory. 5. Enter the IP address of your TFTP server in the TFTP Server IP Addr field. 6. Click OK. The download will begin, and image will be downloaded to the unit 7. Click Configuration > Commands > Reboot. 8. Click Reboot. Install Software from your TFTP Server using the CLI 1. Open the CLI interface to the BS or SS via Telnet or a serial connection. 2. Enter your username and password when prompted. 39 Installation and Initialization Installing Latest Software Tsunami MP.16 3650 System User Guide 3. Enter the following command: download <TFTP Server Address> <File Name> image
(e.g.: download 172.168.12.50 newimage.bin image) The download will begin, and the image will be downloaded to the unit. 4. When the download is complete, type reboot and press Enter. 40 Installation and Initialization First Configuration First Configuration Tsunami MP.16 3650 System User Guide The MP.16 system operates with little required setup. However, the administrator must initially configure certain parameters to allow the BS and SS to communicate and (if desired) to secure the network. The following parameters must be set in order for the units to communicate:
Center frequency: On the BS and SS Web interfaces, click Configuration > Radio to set the desired frequency. See the following:
Radio Configuration in the Base Station Configuration chapter Radio Configuration in the Subscriber Station Configuration chapter. The following parameters must be set to ensure that the network is secure:
IP address:
On the BS Web interface, click Configuration > Networking > Basic to set the IP address. See Networking Configuration in the Base Station Configuration chapter. On the SS Web interface, click Configuration > Network to set the IP address. See Networking Configuration in the Subscriber Station Configuration chapter. Passwords: On the BS Web interface, click Commands > Passwords to set HTTP and CLI passwords. See Passwords in the Commands on BS/SS chapter. Net Entry mode: On the BS Web interface, click Configuration > SS Authentication to set the Net Entry Mode. See Subscriber Station Authentication in the Base Station Configuration chapter. More information and advanced configuration options can be found as follows:
For information and advanced Web-based configuration on the BS, including the use of Service Classes, see Base Station Configuration. For information and advanced Web-based configuration options on the SS, see Subscriber Station Configuration. For information on configuration via the CLI, see Command Line Interface. 41 Base Station Configuration Introduction Tsunami MP.16 3650 System User Guide 3 In the Tsunami MP.16 multipoint system all radios within a sector can be centrally configured from the Base Station. Besides BS and SS configuration, the Base Station Configuration menu includes the authentication and registration of SSs, the assignment of pre-defined SS Classes to those SSs, the creation of new SS Classes, and other service defining parameters. After logging in to the BS, you can access the following configuration pages:
System Configuration MAC Configuration Basic MAC Configuration Advanced MAC Configuration Radio Configuration Radio Downlink Burst Profile Configuration Radio Uplink Burst Profile Configuration Networking Configuration Basic Networking VLANs VLAN Modes: Introduction VLAN ID List Configuring the BS for Transparent VLAN Mode Configuring the BS for Trunk VLAN Mode Bridging RADIUS Servers Syslog Overview Syslog Configuration Syslog Host Table Trap Hosts Static Routes Global Positioning System (GPS) TFTP Table DHCP Server Subscriber Station Authentication Subscriber Station List Subscriber Station List Configuration Service Class Creation Introduction Subscriber Station Classes: Overview Service Class Creation PIR Creation 42 Base Station Configuration Introduction Service Flow Creation Subscriber Station Class Creation Logging Configuration Management Interface Configuration Tsunami MP.16 3650 System User Guide 43 Base Station Configuration System Configuration System Configuration Tsunami MP.16 3650 System User Guide The System Configuration page allows you to set and view BS-specific identification, location, and contact information. Figure 3-1 System Configuration Parameters The following parameters can be configured or viewed from the System Configuration page:
System Description: A read-only description of the Base Station, including software version and build information. System Name: The name assigned to BS. Enter a value between 1 and 255 alphanumeric characters. System Location: The location where the BS is installed. Enter a value between 1 and 255 alphanumeric characters. Contact Name: The name of the person responsible for the BS. Enter a value between 1 and 255 alphanumeric characters. Contact Email: The email address of the person responsible for the BS. Enter a value between 1 and 255 alphanumeric characters. Contact Phone: The telephone number of the person responsible for the BS. Enter a value between 1 and 255 alphanumeric characters. 44 Base Station Configuration MAC Configuration MAC Configuration Tsunami MP.16 3650 System User Guide The MAC controls access to the wireless media. MAC configuration allows administrators to tune their 802.16 MAC implementation based on the needs of their network environment. The following sections provide more information:
Basic MAC Configuration Advanced MAC Configuration Basic MAC Configuration Figure 3-2 Basic MAC Screen The following basic MAC parameters may be set or viewed:
Frame Duration: The maximum frame length. Set the frame length to 5, 10, or 20 ms. Downlink Percentage: This parameter sets the downlink/uplink boundary of the TDD frame by setting the percentage of bandwidth allocated to the downlink. Set the downlink percentage to a value between 10%-90% depending on the frame duration (see the following table). The remainder will be allocated to the uplink. Frame Duration Minimum Downlink Percentage Maximum Downlink Percentage 5 ms 10 ms 20 ms 40%
40%
40%
50%
70%
70%
Frame Synchronization Mode: Set this parameter to Independent. BSID: A 48-bit value, defaulting to 1. Set this to a unique value for each BS, where the upper 24 bits equal the Operator ID. Contact the IEEE Registration Authority to for an Operator ID. If one can not be obtained, use a 24-bit random number until one can be obtained. 45 Base Station Configuration MAC Configuration Advanced MAC Configuration Tsunami MP.16 3650 System User Guide Figure 3-3 Advanced MAC Screen The following advanced MAC parameters may be set or viewed:
NOTE: These parameters should be modified only by experienced users. Please refer to the IEEE 802.16-2004 standard. DCD Interval: Time between the transmissions of Downlink Channel Descriptor (DCD) messages. Setting this value high saves bandwidth, but it may take longer for an SS to enter the network. Enter a value between 100 - 10000 milliseconds. UCD Interval: Time between the transmissions of Uplink Channel Descriptor (UCD) messages. Setting this value high saves bandwidth, but it may take longer for an SS to enter the network. Enter a value between 100 - 10000 milliseconds. Initial Ranging Interval: Time between initial ranging requests. Setting this value high saves bandwidth, but it may take longer to enter the network. Enter a value between 20-2000 milliseconds. TEK Lifetime: The length of time that a Traffic Encryption Key is valid. Minimum value is 30 minutes; maximum is 7 days. The default is 30 minutes. GPS Sync: Enables or disables synchronization of transmission and reception periods with co-located base stations. The GPS accessory must be attached to the BS in order for synchronization to operate. CAUTION: When GPS Sync is enabled, all BSs in an area must use the same frame duration and uplink/downlink modulation. 46 Base Station Configuration Radio Configuration Radio Configuration Tsunami MP.16 3650 System User Guide The BS radio controls the channel bandwidth and frequency, as well as the transmit power. Figure 3-4 Radio Configuration Parameters The following parameters may be set or viewed:
Channel Bandwidth: Set to 3.5 MHz or 7 MHz. Center Frequency: Set the desired center frequency. Transmit Power: Set the downlink transmit power to a value between 5 - 21 dBm. The default is 21 dBm. 47 Base Station Configuration Radio Downlink Burst Profile Configuration Radio Downlink Burst Profile Configuration Tsunami MP.16 3650 System User Guide From the Radio Downlink Burst Profile page, you can enable or disable modulation rates. Figure 3-5 Radio Downlink Burst Profile Configuration Parameters Enable or disable any of the following rates:
BPSK-1/2 QPSK-1/2 QPSK-3/4 16-QAM-1/2 16-QAM-3/4 64-QAM-2/3 64-QAM-3/4 48 Base Station Configuration Radio Uplink Burst Profile Configuration Radio Uplink Burst Profile Configuration Tsunami MP.16 3650 System User Guide From the Radio Uplink Burst Profile page, you can enable or disable modulation rates. Figure 3-6 Uplink Burst Profile Configuration Parameters Enable or disable any of the following rates:
BPSK-1/2 QPSK-1/2 QPSK-3/4 16-QAM-1/2 16-QAM-3/4 64-QAM-2/3 64-QAM-3/4 49 Tsunami MP.16 3650 System User Guide Base Station Configuration Networking Configuration Networking Configuration Network configuration includes the following:
Basic Networking VLANs Bridging RADIUS Servers Syslog Trap Hosts Static Routes Basic Networking Basic networking configuration involves setting the parameters of the BSs Ethernet interface. Figure 3-7 Basic Networking Parameters The following parameters may be set or viewed:
Ethernet Speed and Transmission Mode: This parameter is set to auto-speed-auto-duplex. It is not configurable. Ethernet IP Address: Set the static IP address of the BS. The default IP address of the BS is 192.168.10.1. Ethernet Subnet Mask: Set the subnet mask to which the unit is connected. The default mask is 255.255.255.0. Mcast Max Sustained Data Rate: Set the maximum sustained data rate on multicast packets. This parameter can be set to unlimited, or to a value between 8 - 8192 Kbps (in multiples of 8 Kbps). VLAN Mcast Max Sustained Data Rate: Set the maximum sustained data rate on multicast packets sent across a VLAN. This parameter can be set to unlimited, or to a value between 8 - 1024 Kbps (in multiples of 8 Kbps). Gateway IP Address: Enter the IP address of a gateway on the network. 50 Base Station Configuration Networking Configuration VLANs Tsunami MP.16 3650 System User Guide Virtual Local Area Networks (VLANs) are logical groupings of network resources behind one or more BS and SS. Groupings are based on VLAN IDs. If a data packet is tagged with a VLAN ID, it is called a VLAN-tagged packet. If there is no VLAN ID, the packet is called an untagged packet. All VLAN IDs must be stored in the VLAN ID List. Up to 256 individual VLAN IDs may be stored in this list. See VLAN Modes: Introduction for detailed information on MP.16 operation in each of these modes. See VLAN ID List for VLAN ID List configuration instructions. See Bridging for VLAN Mode configuration instructions. VLAN Modes: Introduction Depending on the VLAN capabilities of sub-networks and devices behind the BS and SS, you can configure the BS and SS for various VLAN modes. The BS can be configured to operate in one of three VLAN modes:
Transparent Trunk Mixed Depending on the BS mode selected, the SS can be configured to operate in one of four VLAN modes:
Transparent: Available when the BS is in Transparent mode. Trunk: Available when the BS is in Trunk mode. Access: Available when the BS is in either Transparent or Trunk mode. Mixed: Available when the BS is in Trunk mode. See the following sections for more information on the functionality of each mode. BS in Transparent Mode When the BS is in Transparent mode, the SS may be in either Transparent or Access mode. When both the BS and SS are in Transparent mode VLAN-tagged or untagged packets are accepted and forwarded by the BS and SS, unless they are discarded due to PIR restrictions (see Networking Parameters in the Service Class Creation section). The BS and SS will process both tagged and untagged packets from both the wireless and Ethernet interfaces. When the BS is in Transparent mode and the SS is in Access mode, the SS processes only untagged packets from the Ethernet interface, discarding any tagged packets it receives. Upon receiving an untagged packet, the SS tags it with an assigned VLAN ID and priority provisioned by the BS. When the SS receives tagged packets from the wireless interface, it removes the VLAN tag and sends only untagged packets to the Ethernet interface. Figure 3-8 illustrates the exchange of packets when the BS is in Transparent mode and registered SSs are in either Transparent or Access mode. Table 3-1 provides a detailed summary of BS and SS functionality when the BS is in Transparent mode. 51 Base Station Configuration Networking Configuration Tsunami MP.16 3650 System User Guide Figure 3-8 BS in Transparent Mode Table 3-1 BS in VLAN Transparent ModeSummary BS in Transparent VLAN Mode SS in Transparent or Access VLAN Mode BS forwards both tagged and untagged frames BS allows any untagged management frames to access the device Transparent Mode:
SS forwards both tagged and untagged frames SS allows any untagged management frames to access the device Access Mode:
SS discards any tagged framed received from the Ethernet interface SS tags any untagged frames received from the Ethernet interface with the configured VLAN ID and priority and forwards them to the BS SS untags all frames received from the BS that are tagged with the VLAN ID and forwards them to the Ethernet Interface or to the internal IP address. SS discards any frames received from the BS with a tag other than the VLAN ID SS tags any management frames that it generates with the configured VLAN ID and priority when sending them on the wireless interface SS sends all management frames as untagged when sending them on the Ethernet interface BS in Trunk Mode When the BS is in Trunk mode, the SS may be in either Trunk, Access, or Mixed mode. When both the BS and SS are in Trunk mode, packets are forwarded only if they are tagged with one of the allowed VLAN IDs configured on the BS or provisioned to the SS. Any untagged frames, and any frames with a tag that is not found in the VLAN ID List, are discarded. When the BS is in Trunk mode and the SS is in Access mode, the SS processes only untagged packets from the Ethernet interface, discarding any tagged packets it receives. Upon receiving an untagged packet, the SS tags it with an assigned VLAN ID and priority provisioned by the BS. When the SS receives tagged packets from the wireless interface, it removes the VLAN tag and sends only untagged packets to the Ethernet interface. 52 Base Station Configuration Networking Configuration Tsunami MP.16 3650 System User Guide When the BS is in Trunk mode and the SS is in Mixed Mode, the SS processes tagged and untagged packets. Upon receiving an untagged packet, the SS tags it with an assigned VLAN Access ID and priority provisioned by the BS. Upon receiving a tagged packet, the SS forwards it only if its tag matches the configured VLAN Access ID or one of the VLAN IDs configured in the VLAN ID Trunk list. Figure 3-9 illustrates the exchange of packets when the BS is in Trunk mode and registered SSs are in either Trunk, Access, or Mixed mode. Table 3-2 provides a detailed summary of BS and SS functionality when the BS is in Trunk mode. Figure 3-9 BS in Trunk Mode 53 Base Station Configuration Networking Configuration Table 3-2 BS in VLAN Trunk ModeSummary Tsunami MP.16 3650 System User Guide BS in Trunk VLAN Mode SS in Trunk or Access VLAN Mode BS discards all untagged frames received from the Ethernet interface or from any of the associated SSs. BS forwards frames received from the Ethernet interface or from any associated SS that are tagged with the configured VLAN IDs The BS tags all management frames that it generates with the configured Management VLAN ID and priority The BS allows only management frames tagged with the configured Management VLAN ID to access it. Trunk Mode:
SS discards all untagged frames received from the Ethernet interface or from the BS. SS forward only frames received from the Ethernet Interface or from the wireless interface that are tagged with the configured VLAN IDs; it discards all other tagged frames. SS tags any management frames that it generates with the configured Management VLAN ID and priority SS allows only management frames tagged with the configured Management VLAN ID to access it Access Mode:
SS discards any tagged framed received from the Ethernet interface SS tags any untagged frames received from the Ethernet interface with the configured VLAN ID and priority and forwards them to the BS SS untags all frames received from the BS that are tagged with the VLAN ID and forwards them to the Ethernet Interface or to the internal IP address. SS discards any frames received from the BS with a tag other than the VLAN ID SS tags any management frames that it generates with the configured VLAN ID and priority when sending them on the wireless interface SS sends all management frames as untagged when sending them on the Ethernet interface Mixed Mode:
SS tags any untagged frames received from the Ethernet interface with the configured VLAN Access ID and priority and forwards them to the BS When it receives a tagged from the Ethernet or Wireless interface, the SS forwards only frames that are tagged with the VLAN IDs configured in the Trunk list; it discards all other tagged frames. SS untags all frames received from the BS that are tagged with the VLAN Access ID and forwards them to the Ethernet Interface or to the internal IP address. SS tags any management frames that it generates with the configured VLAN Access ID and priority when sending them on the wireless interface SS sends all management frames as untagged when sending them on the Ethernet interface 54 Base Station Configuration Networking Configuration VLAN ID List Tsunami MP.16 3650 System User Guide Figure 3-10 VLAN ID List Configuration To configure the VLAN ID List:
1. Enter a number or range of numbers between 1 and 4095 in the VLAN ID List Entry field. Up to 256 entries may be added to the VLAN ID List. 2. Click the right arrow
. To remove a VLAN ID from the list, select it and click the left arrow. Bridging From the Bridging Parameters page, you can set the VLAN mode and associated bridging parameters for the BS. See the following sections:
Configuring the BS for Transparent VLAN Mode Configuring the BS for Trunk VLAN Mode 55 Base Station Configuration Networking Configuration Configuring the BS for Transparent VLAN Mode Tsunami MP.16 3650 System User Guide Figure 3-11 Bridge Parameters (Transparent Mode) 1. Set the VLAN Mode to Transparent. NOTE: The VLAN Priority and Management VLAN ID fields are not configurable when VLAN Mode is set to Transparent. 2. Set Repeating Mode to Enable or Disable. When enabled, the BS allows traffic to be bridged between SSs. Configuring the BS for Trunk VLAN Mode 1. Set the VLAN Mode to Trunk. Figure 3-12 Bridge Parameters (Trunk Mode) NOTE: If you have not added VLAN IDs to the VLAN ID List, an error message will be displayed. For information on configuring the VLAN ID List, see VLAN ID List. 56 Base Station Configuration Networking Configuration Tsunami MP.16 3650 System User Guide 2. Set the VLAN Priority: Priority to be given to the VLAN Management ID; select a number between 0 and 7. 3. Select a VLAN Management ID. This is one VLAN ID from the VLAN ID List that serves as the Management ID. Only VLAN packets tagged with this ID will have management access to the BS. CAUTION: VLAN Management ID must be set when the VLAN mode is set to Trunk. 4. Set Repeating Mode to Enable or Disable. When enabled, the BS allows traffic to be bridged between SSs. RADIUS Servers In large networks with multiple units, you can maintain a list of MAC addresses in a centralized location using a RADIUS authentication server that grants or denies access. If you use RADIUS authentication, you must specify a primary RADIUS server and associated parameters. The secondary server is not configurable at this time. Figure 3-13 RADIUS Server Parameters The following parameters may be viewed or configured:
Address Format: The format for the RADIUS server address is IP Address. Name/IP Address: Enter the IP address of the RADIUS server. Destination Port: Enter the port number which the BS and the server will use to communicate. The range is 1000-65536; by default, RADIUS servers communicate on port 1812. Shared Secret: Enter the password (between 1 and 255 character) shared by the RADIUS server and the BS. The same password must also be configured on the RADIUS server. The default password is public. Response Time: Enter the maximum time, in seconds, that the BS should wait for the RADIUS server to respond to a request. The range is 1-10 seconds; the default is 3 seconds. Maximum Retransmissions: Enter the maximum number of times an authentication request may be transmitted. The range is 0 to 4, the default is 3. Status: Select Enable from the drop-down box to enable the RADIUS server, or select Disable to disable the RADIUS server. 57 Base Station Configuration Networking Configuration Syslog Overview Tsunami MP.16 3650 System User Guide When Secondary Management is enabled on the SS, the MP.16 supports Syslog functionality. Up to two Syslog servers can be configured, each offering the following alert levels:
Alert Type Severity Level Emergency Alert Critical Error Warning Notice Informational Debug 0 1 2 3 4 5 6 7 Each Syslog message includes a time-stamp, the severity level, and a brief description of the event. Supported Syslog messages are as follows:
Description TFTP upload request failed TFTP upload request successful TFTP download request failed TFTP download request successful System manually rebooted System cold/warm start Event log reset Interface up Interface down SS link lost SS modulation dropped to BPSK SS RSSI dropped below low threshold SS RSSI increased above high threshold GPS not present GPS lock lost Severity Additional Information Alert (1) Warning (4) Alert (1) Warning (4) Alert (1) Alert (1) Warning (4) Alert (1) Alert (1) Alert (1) Critical (2) Critical (2) Critical (2) Alert (1) Alert (1) BS Only Includes interface number Includes interface number BS Only BS Only BS Only Syslog Configuration From the Syslog Configuration page, you can enable or disable Syslog server functionality. 58 Base Station Configuration Networking Configuration Tsunami MP.16 3650 System User Guide Figure 3-14 Syslog Configuration Syslog Host Table Use the Syslog Host Table page to add and configure the Syslog host(s). Figure 3-15 Syslog Host Table (Syslog Server List) 1. Do one of the following:
Click Add to add a new Syslog server to the list. You may add up to two servers. Click the radio button next to one of the Syslog servers IP addresses and click Clone to make a copy of the Syslog server entry. 59 Base Station Configuration Networking Configuration Tsunami MP.16 3650 System User Guide Click the radio button next to one of the Syslog servers IP addresses and click Edit to edit an existing Syslog server entry. Click the radio button next to one of the Syslog servers IP addresses and click Delete to delete that Syslog server from the list. 2. If you are adding or cloning a Syslog server entry, specify the IP address of the new server and click Add. If you are editing an Syslog server entry, you will not be prompted to specify an IP address. NOTE: When adding a server, you must enter an IP address. Do not enter a name. Figure 3-16 Adding a Syslog Host The Syslog Host Configuration page will be displayed. Figure 3-17 Syslog Host Configuration 60 Base Station Configuration Networking Configuration Tsunami MP.16 3650 System User Guide 3. Select the Priority. This selection sets the lowest level alert to be sent to the Syslog server. 4. Enter a Comment. This field is optional. 5. Enable or disable this Syslog server using the Status drop-down menu. 6. Click OK. Trap Hosts Traps are sent to the configured list of Trap Hosts. The following traps are supported:
Description Severity Additional Information TFTP request failed TFTP request successful System manually rebooted System cold/warm start Event log reset Interface up Interface down SS link lost SS modulation dropped to BPSK Service Flow creation GPS not present GPS lock lost 1 4 1 1 4 1 1 1 2 4 Alert (1) Alert (1) From the Trap Hosts page, you can configure the Trap Hosts. BS only Includes interface number Includes interface number BS only BS only BS Only BS Only Figure 3-18 Trap Host List 1. Do one of the following:
Click Add to add a new Trap host to the list. You may add up to two servers. Click the radio button next to one of the Trap hosts IP addresses and click Clone to make a copy of the Trap host entry. 61 Base Station Configuration Networking Configuration Tsunami MP.16 3650 System User Guide Click the radio button next to one of the Trap hosts IP addresses and click Edit to edit an existing Trap host entry. Click the radio button next to one of the Trap hosts IP addresses and click Delete to delete that Trap host from the list. 2. If you are adding or cloning a Trap host entry, specify the IP address of the new host and click Add. If you are editing an Trap host entry, you will not be prompted to specify an IP address. NOTE: When adding a host, you must enter an IP address. Do not enter a name. Figure 3-19 Adding a Trap Host The Trap Host Configuration page will be displayed. Figure 3-20 Subscriber Station Configuration 3. Set the Password for the Trap host. 4. Enter a Comment. This field is optional. 5. Enable or disable this Trap host using the Status drop-down menu. 62 Base Station Configuration Networking Configuration 6. Click OK. Static Routes Tsunami MP.16 3650 System User Guide From the Static Routes page, you can configure up to 16 fixed routes from the BSs Ethernet address to other points on the network. Each static route consists of destination network, subnet mask, and a gateway address. Figure 3-21 Static Routes List 1. Do one of the following:
Click Add to add a Static Route to the list. Click the radio button next to one of the routes and click Edit to edit an existing Static Route. Click the radio button next to one of the routes and click Delete to delete that route. If you are adding or editing a Static Route, the Static Route page will be displayed. Figure 3-22 Static Route Configuration 63 Base Station Configuration Networking Configuration 2. Enter the following information:
IP Address: The destination IP address. Subnet Mask: Subnet mask of the destination. Gateway Address: Default gateway address of the destination. 3. Click OK. Tsunami MP.16 3650 System User Guide 64 Base Station Configuration Global Positioning System (GPS) Global Positioning System (GPS) Tsunami MP.16 3650 System User Guide The Base Station can be configured (via advanced MAC configuration) to enable GPS. In this mode, the BS will require a functioning GPS recevier to be connected to its GPS/SYNC port. Once the BS attains synchronization with the one pps signal of the GPS recevier, it will detect any timing delta between the GPS one PPS signal ad its internal start of transmit frame time. Accordingly, the BS start of transit frame will be adjusted to match the one pps signal of the GPS recevier. Whenever GPS is enabled and there is synchronization between its one pps signal and the BS, the BS will mute its radio transmission until such synchronization is attained. GPS Synchronization CAUTION: DO NOT enable GPS Synchronization on a Base Station unless you are concurrently connecting a GPS unit to the Base Station. With GPS enabled, if a GPS unit is not connected to the Base Station, or if the GPS unit loses satellite reception, the Base Stations transmittor will shut down until GPS satellite reception is restored. GPS Synchronization is enabled on the Tsunami MP.16-3650 Base Station via the Advanced MAC Configuration screen. After selecting Enable from the GPS ENable/Disable menu, click the OK button. To complete the process, the Base Station must be rebooted. GPS Unit Installation Position the GPS unit in a location where the antenna plate is parallel to the Earth/horizon. The GPSdomed antenna should be exposed to as much of the sky possible (clear line-of-sight) so that the GPS unit can always acquire at least four GPS satellites to extract timing signals for the Base Station transmission synchronization. Insert the band clamp through the slots in the GPS unit mounting bracket and around the mounting pole. Tighten the clamp around the mounting pole and then tighten the screw in the clamp to secure the GPS unit mounting bracket to the mounting pole. Attach the GPS unit mounting bracket using the #10-32x3/8 SEm screws (the screws with attached washers). Connecting the GPS Unit to the Base Station Remove the weather-protection cap from the Base Stations GPS/SYNC connection enclosure to expose the RJ45 jack. Plug the GPS units connection cable (RJ45 plug) into the RJ45 jack of the Base Station. NOTE: When power is applied to the Base Station, the GPS unit automatically be powered as well. Secure the GPS connection cable assembly as follows:
1. Apply two wraps of Teflon tape around the threads of the Base Stations GPS/SYNC RJ45 jack enclosure in a clockwise direction. 2. Make sure that the rubber gasket is properly seated in the sealing cap of the sealing cap/lock nut assembly. 3. Slide the sealing cap/lock nut assembly over the RJ45 jack and thread onto the enclosure. Hand-tighten first, then use an adjustable wrench or similar tool to tighten one more quarter turn. 4. Tighten the lock nut (Torque 4 N.m/35in-Ibs). 5. Thread the sealing nut onto the sealing cap/lock nut assembly must be fully tightened over the RJ45 connector before the sealing nut is fully tightened. If not fully tightened first, the GPS unit connection cable may twist and be damaged. CAUTION: The lock nut on the sealing cap/lock nut assembly must be fully tightened over the RJ45 connector before the sealing nut is fully tightened. If not fully tightened first, the GPS unit connection cable may twist and be damaged. Waterproof of the GPS connector assembly in the same manner as for the Power/Ethernet connector assembly. 65 Base Station Configuration Global Positioning System (GPS) Verifying Base Station GPS Synchronization Tsunami MP.16 3650 System User Guide Via the Base Stations web interface, GPS synchronization status can be obversedvia the Base Station GPS Statistics monitor page. Figure 3-23 Advenced MAC Configuration When GPS is disabled on the Base Station, the Base Station will show disabled:
Figure 3-24 BSU GPS disabled mode 66 Base Station Configuration Global Positioning System (GPS) Tsunami MP.16 3650 System User Guide When GPS is enabled on the Base Station, and the GPS recevier is either not connected or is still searching for satellites, the Base Station will show not found:
Figure 3-25 BSU GPS not found mode When the GPS has acquired the satellite signals, but the Base Station has not yet synchronized its internal timing, the Base Station will show not locked:
Figure 3-26 BSU GPS not locked mode When the GPS receiver has processed the GPS timing signal and the Base Station is properly synchronized, the base Station will show locked:
67 Base Station Configuration Global Positioning System (GPS) Tsunami MP.16 3650 System User Guide Figure 3-27 BSU GPS Locked mode Cable Assembly for GPS Unit NOTE: This document provides the pinout and cable assembly for the GPS receiver only for reference purposes. The GPS kit can be ordered from Proxim and is provided with the assembly/components, as stated in this document. Secondary Management Secondary Management allows a Subscriber Station to acquire a set of network settings including IP address and, if necessary, to download a new configuration file. When secondary management is enabled on the SS, the SS sends a DHCP request to BS, which is functioning as a DHCP server. The SS then configures itself based on the DHCP response received. The DCHP response includes:
The IP address to be used by the SS The subnet mask to be used by the SS The IP address of the TFTP server that will be used to download a new software image file, if necessary The name of the SS software image file to be read from the TFTP server, if necessary A list of addresses of one or more routers to be used for forwarding SS-originated IP traffic. The SS uses the first router in this list as the Default Gateway for all its own IP traffic. It adds others (if present) to the IP Route Table. A list of Syslog servers to which logging information may be sent A list of time servers from which the current time may be obtained The time offset of the SS from UTC. This is used by the SS to calculate the local time for use in time-stamping error logs. After the SS has successfully received a valid DHCP response from the BS, the TFTP client allows the Subscriber Station to download a specified software image file from a specified TFTP Server location. The TFTP Server IP address and the File Name are retrieved from the DHCP Response. 68 Base Station Configuration Global Positioning System (GPS) Tsunami MP.16 3650 System User Guide Secondary management is enabled/disabled on the SS (see Network Configuration in the Subscriber Station Configuration chapter). TFTP and DHCP settings are configured on the BS. See the following sections:
TFTP Table DHCP Server TFTP Table Use the TFTP Table page to configure the parameters used to provide a software image file to the SS (when necessary) when secondary management is enabled. Entries in the TFTP Secondary Management List Table are based on SS hardware versions in your network. 69 Base Station Configuration Global Positioning System (GPS) Tsunami MP.16 3650 System User Guide Figure 3-28 TFTP Table 1. Do one of the following To add TFTP settings for a new hardware version, click Add. To edit TFTP settings for an existing hardware version, select the radio button next to the version you wish to modify, and click Edit. 2. If you are adding a hardware version, you will be prompted to select the hardware version from a drop-down menu. Then click Add. If you are editing an existing hardware version, you will not need to select a version. Figure 3-29 Adding Hardware Identifier The Secondary Management TFTP Configuration page will be displayed. 70 Base Station Configuration Global Positioning System (GPS) Tsunami MP.16 3650 System User Guide Figure 3-30 Secondary Management TFTP Configuration 3. Enter the Software Version number of the image to be used with the selected hardware. 4. Enter the IP address of the TFTP Server from which the specified software image is available for download. 5. Enter the Upgrade File Name of the software image to be downloaded. 6. Click OK. DHCP Server Use the DHCP Server page to configure and enable the BS to function as a DHCP server when secondary management is enabled on the SS. Figure 3-31 1. Enter the following information:
Base Station Secondary Management IP: The IP address of the BS to be used when functioning as a DHCP server. Base Station Secondary Management Mask: The mask of the BS to be used when functioning as a DHCP server. 71 Base Station Configuration Global Positioning System (GPS) Tsunami MP.16 3650 System User Guide Pool Start IP Address: The first IP address in the DHCP pool. Pool End IP Address: The last IP address in the DHCP pool. 2. Click OK. 72 Base Station Configuration Subscriber Station Authentication Subscriber Station Authentication Tsunami MP.16 3650 System User Guide Subscriber Station Authentication Parameters determine the authentication method for SSs entering the BSs network, and specify a default Subscriber Station class used for any SS entering the network without an otherwise predefined class. Figure 3-32 Subscriber Station Authentication Parameters The following parameters can be configured or viewed from the Subscriber Station Authentication page:
Net Entry Mode: Select one of the following:
Unrestricted: All Subscriber Stations may enter the network. This is the default selection. NOTE: Unrestricted access is intended to simplify initialization and configuration, but as it is not secure, it is not recommended for a secure deployment. Internally Authorized: Only Subscriber Stations listed in the Base Stations list of authorized SSs can enter the network. See Subscriber Station List. Externally Authorized: Only Subscriber Stations listed in the configured RADIUS servers list of authorized SSs can enter the network. When changing to external authorization from any other authorization type, SSs currently in the SS List must be manually deleted. Default SS Class: When the Net Entry mode is set to Unrestricted, select the default SS class assigned to all SSs entering the network without a preassigned SS class. The default is Unlimited Best Effort. See Subscriber Station List for information on assigning non-default SS Classes from a list of pre-defined SS classes and Service Class Creation for information on creating new classes. NOTE: When the Net Entry mode is set to Internally Authorized, the SS Class is assigned when the SS is added to the Subscriber Station List. When the Net Entry mode is set to Externally Authorized, the SS class is assigned by the configured RADIUS server. 73 Base Station Configuration Subscriber Station List Subscriber Station List Tsunami MP.16 3650 System User Guide From the Subscriber Station List page, you can add SSs to your network, associate them with an SS Class, and configure select SS-specific parameters. Figure 3-33 Subscriber Station List All SSs in the Subscriber Station List are authorized to join the network. Depending on the Net Entry mode of the Base Station, this list is populated as follows:
Unrestricted mode: SSs are automatically added to the Subscriber Station List upon registering with the network. The default SS Class configured on the Subscriber Station Authentication page is initially assigned to SSs. Internal authorization mode: Each SS must be manually added to the Subscriber Station List. An SS class is assigned manually during this process. CAUTION: In internal authorization mode, only SSs in the Subscriber Station List are authorized to join the network. External authorization mode: SSs are added to the Subscriber Station List automatically by the configured RADIUS server. The RADIUS server assigns an SS class. CAUTION: When changing to external authorization from any other authorization type, SSs currently in the SS List must be manually deleted. The administrator may optionally configure parameters of individual SSs on the list, including assigning an SS class, overriding particular elements of an assigned SS Class, and resetting overridden parameters to their default states. 74 Base Station Configuration Subscriber Station List Subscriber Station List Configuration Tsunami MP.16 3650 System User Guide NOTE: You must reboot the SS for any configuration changes to take effect. 1. Do one of the following:
Click Add to add an authorized SS to the list. Click the radio button next to one of the SS MAC addresses and click Clone to make a copy of SS entry. Click the radio button next to one of the SS MAC addresses and click Edit to edit an existing SS entry. Click the radio button next to one of the SS MAC addresses and click Delete to delete that SS from the list. If you are adding or cloning an SS entry, specify the MAC address of the new SS and click Add. If you are editing an SS entry, you will not be prompted to specify a MAC address. 2. Figure 3-34 Adding a Subscriber Station The Subscriber Station page will be displayed. Figure 3-35 Subscriber Station Configuration 3. Select an SS Class. The drop-down menu displays the currently assigned SS Class. Use the drop-down menu to select a different SS Class. If a desired class of service is not contained in this list, you may create it (see Service Class Creation) and then return to the Subscriber Station List page to assign it to one or more SSs. 75 Base Station Configuration Subscriber Station List Tsunami MP.16 3650 System User Guide 4. Specify an Uplink Modulation for the SS. When adaptive is selected, the SS will continually monitor and adjust to select the best modulation for the link conditions. 5. Specify an Downlink Modulation for the SS. When adaptive is selected, the SS will continually monitor and adjust to select the best modulation for the link conditions. 6. Set the VLAN parameters of the SS:
To use the VLAN parameters associated with the assigned SS Class, select Inherited from the VLAN Mode drop-down menu, and click OK. The VLAN Management ID configured with the SS Class will be used; this field is not configurable here. To override the VLAN parameters associated with the assigned SS Class, select Transparent, Access, Trunk, or Mixed from the drop-down menu. and configure parameters as described in the following sections:
To set the VLAN mode to Transparent, see Configuring an Individual SS for Transparent Mode (Override) To set the VLAN mode to Access, see Configuring an Individual SS for Access Mode (Override) To set the VLAN mode to Trunk, see Configuring an Individual SS for Trunk Mode (Override) To set the VLAN mode to Mixed, see Configuring an Individual SS for Trunk Mode (Override) NOTE: To reset an override to the value specified by the SS Class, set VLAN Mode to Inherited. 76 Base Station Configuration Subscriber Station List Tsunami MP.16 3650 System User Guide Configuring an Individual SS for Transparent Mode (Override) If the BSs VLAN mode is set to Transparent, the SSs VLAN mode may be set to Transparent. With the SSs VLAN mode set to Transparent, the following screen will be displayed:
Figure 3-36 SS VLAN Configuration Override (Transparent Mode) In Transparent mode, all tagged and untagged packets can access the device. There is therefore no need to specify a VLAN Management ID; this field is not configurable. Once the VLAN Mode is set, click OK. 77 Base Station Configuration Subscriber Station List Tsunami MP.16 3650 System User Guide Configuring an Individual SS for Access Mode (Override) If the BSs VLAN mode is set to Transparent or Trunk, the SSs VLAN mode may be set to Access. With the SSs VLAN mode set to Access, the following screen will be displayed:
Figure 3-37 SS VLAN Configuration Override (Access Mode) In Access mode, only one VLAN ID may be specified as having access to the SS. This VLAN ID has management access. NOTE: When you move the VLAN ID to the Selected Access VLAN ID list, the VLAN Management ID field will be automatically populated with this ID. Set the following parameters and then click Save & Finish:
Selected VLAN Access ID: Select one VLAN ID from the Available VLAN ID List to serve as the Management ID. Only VLAN packets tagged with this ID will have access to and be able to manage the SS. To designate a VLAN ID as the Management ID, select the VLAN ID from Available VLAN ID List, and click the right arrow
. To designate a different VLAN ID as the Management ID, remove the current VLAN ID by clicking the left arrow, and select a different VLAN ID from the list. VLAN Priority: Priority to be given to the Selected Access VLAN ID; select a number between 0 and 7. For information on configuring the Available VLAN ID List, see VLAN ID List. 78 Base Station Configuration Subscriber Station List Tsunami MP.16 3650 System User Guide Configuring an Individual SS for Trunk Mode (Override) If the BSs VLAN mode is set to Trunk, the SSs VLAN mode may be set to Trunk. With the SSs VLAN mode set to Trunk, the following screen will be displayed:
Figure 3-38 SS VLAN Configuration Override (Trunk Mode) In Trunk mode, up to 16 VLAN IDs may be specified as having access to the SS. Additionally, one of these VLAN IDs must be designated as the VLAN Management ID for the VLAN. NOTE: The total number of VLANs and Service Flows must not exceed 20. Set the following parameters and click OK:
VLAN Management ID: Select one VLAN ID from the Selected Trunk VLAN ID List to serve as the Management ID. Only VLAN packets tagged with this ID will have management access to the SS. If the VLAN ID entered in this field is not contained in the Selected Trunk VLAN ID List, an error message will be displayed when you click OK. Selected VLAN ID List: You may add up to 16 VLAN IDs to this list. To add a VLAN ID, select the VLAN ID from Available VLAN ID List, and click the right arrow left arrow. NOTE: After clicking OK, the selected Management ID will be automatically moved to the top of the Selected Trunk
. To remove a VLAN ID from the list, select the ID and click the VLAN ID List. For information on configuring the Available VLAN ID List, see VLAN ID List. 79 Base Station Configuration Subscriber Station List Tsunami MP.16 3650 System User Guide Configuring an Individual SS for Mixed Mode (Override) If the BSs VLAN mode is set to Trunk, the SSs VLAN mode may be set to Mixed. With the SSs VLAN mode set to Trunk, the following screen will be displayed:
Figure 3-39 SS VLAN Configuration Override (Mixed Mode) In Mixed mode, one VLAN Access ID and up to 16 VLAN Trunk IDs may be specified as having access to the SS. The VLAN Access ID has management access. NOTE: When you move a VLAN ID to the Selected Access VLAN ID list, the VLAN Management ID field will be automatically populated with this ID. NOTE: The total number of VLANs and Service Flows must not exceed 20. When using Mixed mode, this number includes the Access VLAN ID as well as the Trunk VLAN IDs. Set the following parameters and click OK:
Selected Access VLAN ID: Select one VLAN ID from the Available VLAN ID List to serve as the Access VLAN ID. Only VLAN packets tagged with this ID will have access to and be able to manage the SS. To designate a VLAN ID as the Access VLAN ID, select the VLAN ID from Available VLAN ID List, and click the right arrow
. To designate a different VLAN ID as the Management ID, remove the current VLAN ID by clicking the left arrow, and select a different VLAN ID from the list. 80 Base Station Configuration Subscriber Station List Tsunami MP.16 3650 System User Guide VLAN Priority: Priority to be given to the Selected Access VLAN ID; select a number between 0 and 7. Selected Trunk VLAN ID List: You may add up to 16 VLAN IDs to this list. To add a VLAN ID, select the VLAN ID
. To remove a VLAN ID from the list, select the ID and click from Available VLAN ID List, and click the right arrow the left arrow. For information on configuring the Available VLAN ID List, see VLAN ID List. 81 Base Station Configuration Service Class Creation Service Class Creation Introduction Tsunami MP.16 3650 System User Guide When a Subscriber Station enters the network, its MAC address must be added to the network and associated with an SS class. Upon entering the network, an SS uses either the default SS class configured on the BS (under the Subscriber Station Authentication tab) or a pre-assigned SS class (assigned by the BS under the Subscriber Station List tab or by the configured RADIUS server). The MP.16 system comes with several predefined SS classes; however, the system also allows you to edit these classes or define custom classes to fit your particular systems needs. The following sections provide more information on SS classes and custom SS class creation. Subscriber Station Classes: Overview Service Class Creation PIR Creation Service Flow Creation Subscriber Station Class Creation For instructions on assigning a pre-defined class to an SS, see Subscriber Station Authentication (to select a default SS class for all SSs entering the network when the Net Entry mode is set to Unrestricted) and Subscriber Station List (to assign SS classes to individual SSs when the Net Entry mode is set to Internally Authorized). NOTE: When the Net Entry mode is set to Externally Authorized, the SS class is assigned by the configured RADIUS server. Subscriber Station Classes: Overview Figure 3-40 depicts the process of defining custom Subscriber Station classes. Figure 3-40 Defining SS Classes The fundamental building blocks of an SS class are:
PIRs, which determine which packets are mapped to which service flows. 82 Base Station Configuration Service Class Creation Tsunami MP.16 3650 System User Guide Service Flows, including their direction and QoS traffic scheduling mechanism(s) Networking Parameters, including VLAN properties. Packet Identification Rules PIRs are rules that are matched against fields of incoming packets for the purpose of mapping the packet onto the appropriate service flow. A PIR includes one or more of eleven different classifier fields, which, if included, are matched against the incoming packet. If a PIR includes multiple classifiers, every included field must match the incoming packet for the rule to match. The only parts of the packet that are inspected are those corresponding to classifiers included in the PIR. PIRs are extremely flexible and can be used In many different ways. Some examples include:
Using the ToS field in a classification rule to identify a certain class of differentiated IP traffic. This then could be used to map from the layer 3 QoS to the underlying 802.16 service flow providing the necessary QoS guarantees. Using the destination IP address field to identify uplink traffic destined to a particular server address, such as a VoIP gateway. This could be used to identify VoIP traffic and map it to the appropriate service flow. A priority is used when assigning a PIR to a Service Flow during SS Class configuration (as described in Step 2:
Associate PIRs with Service Flows later in this guide). This priority is used to filter traffic, with higher priority PIRs being serviced first. PIR priority is not used per Service Flow on the BS, so unique PIR priority values across all SS Classes are required to ensure proper traffic prioritization. Service Flows As PIRs determine which traffic gets directed to which Service Flow, the Service Flows, in turn, determine the traffics QoS treatment. The SF direction specifies whether the service flow is to be used by uplink (to the BS) or downlink (from the BS) traffic. An uplink service flow is intended for traffic flowing from an SS to the BS. A downlink service flow is intended for traffic flowing from a BS to an SS. SF Quality of Service (QoS) The SFs QoS traffic scheduling settings define the method by which bandwidth is allocated for packets sent over that service flow. Quality of Service (QoS) for networks is an industry-wide set of standards and technologies for ensuring high-quality performance for critical applications. By using QoS mechanisms, network administrators can use existing resources efficiently and ensure the required level of service without reactively expanding or over-provisioning their networks. Traditionally, the concept of quality in networks meant that all network traffic was treated equally. The result was that all network traffic received the networks best effort, with no guarantees for reliability, delay, variation in delay, or other performance characteristics. With best-effort delivery service, however, a single bandwidth-intensive application can result in poor or unacceptable performance for all applications. The QoS concept of quality is one in which the requirements of some applications and users are more critical than others, which means that some traffic needs preferential treatment. The goal of QoS is to provide preferential delivery service for the applications that need it by ensuring sufficient bandwidth, controlling latency and jitter, and reducing data loss, while also making sure that providing priority for one or more flows does not make other flows fail. QoS lets you provide better service to certain flows of traffic. This is done by either raising the priority of a flow or limiting the priority of another flow. You can raise the priority of a flow by queuing and servicing queues in different ways:
Raise priority by dropping lower-priority flows before higher-priority flows. Police and shape priority to a flow by limiting the throughput of other flows. 83 Base Station Configuration Service Class Creation Tsunami MP.16 3650 System User Guide Limit large flows to show a preference for small flows. The Tsunami MP.16 system lets complex networks control and predictably service a variety of networks applications and traffic types. Almost any network can take advantage of QoS for optimum efficiency, whether it is a small corporate network, an Internet Service Provider, or an enterprise network. QoS Traffic Scheduling Mechanisms The MP.16 system supports four types of QoS traffic scheduling mechanisms:
Unsolicited Grant Services (UGS): UGS is designed to support constant bit rate services like T1/E1 and VoIP without silence suppression. In the MP.16 system, UGS QoS parameters include maximum sustained data rate, maximum latency, and tolerable jitter. Real-Time Polling Services (rtPS): rtPS is designed to support real-time services that generate variable size data packets on a periodic basis, such as MPEG video or VoIP with silence suppression. In the MP.16 system, rtPS QoS parameters include maximum sustained data rate, minimum reserved traffic rate, and maximum latency. Non-Real-Time Polling Services (nrtPS): nrtPS is designed to support non-real-time services that require variable size data grant burst types on a regular basis. In the MP.16 system, nrtPS QoS parameters include maximum sustained data rate, minimum reserved traffic rate, and traffic priority. Best Effort Services: BE services are typically provided by the Internet today for Web surfing. In the MP.16 system, BE QoS parameters include maximum sustained data rate and traffic priority. Networking Parameters SS class networking parameters include VLAN settings. These settings are dependent on the VLAN mode of the Base Station. See VLANs in the Networking Configuration section for a description of VLAN functionality. 84 Base Station Configuration Service Class Creation Service Class Creation Tsunami MP.16 3650 System User Guide NOTE: You must reboot the SS for any configuration changes to take effect. The steps for creating SS classes are as follows:
PIR Creation Service Flow Creation Subscriber Station Class Creation Step 1: Select Service Flows Step 2: Associate PIRs with Service Flows Step 3: Networking Parameters PIR Creation From the Packet Identification Rule List page, you can create, delete, and edit up to 512 PIRs that identify specific traffic types, including those that are predefined for you (see Pre-Defined PIRs). 1. Click Service Class Creation > PIRs Figure 3-41 Packet Identification Rule List 2. Do one of the following:
Click Add to create a new PIR. Click the radio button next to one of the PIRs and click Clone to make a copy of that PIR. Click the radio button next to one of the PIRs and click Edit to edit an existing PIR. Click the radio button next to one of the PIRs and click Delete to delete that PIR from the list. If you are adding or cloning a PIR, specify a unique PIR Name between 1 and 32 characters, and click Add. 3. 85 Base Station Configuration Service Class Creation Tsunami MP.16 3650 System User Guide Figure 3-42 Add Packet Identification Rules Screen The Configuration screen for the PIR will be displayed. 4. Place a check mark in the box next a classifier name to configure it and add it to the PIR. Uncheck the box to remove the classifier from the PIR. In the following figure, the IP TOS and VLAN ID classifiers are selected and expanded for configuration. NOTE: If you are editing or cloning a PIR, some classifiers will already be expanded and configured; you may modify these classifiers as needed or uncheck the box to remove them from the PIR. Figure 3-43 PIR Classifier List 5. If packets matching the classifiers configured below are to be blocked, select the PIR Blocked box. If this box is not checked, packets matching the classifiers configured below will be allowed. 6. Configure the desired classifiers as follows. 86 Base Station Configuration Service Class Creation Tsunami MP.16 3650 System User Guide IP TOS: To identify a packet by IP Type of Service, specify a minimum TOS value, maximum TOS value, and mask. The minimum and maximum values must be numeric values between 0 and 255, with the minimum being equal to or less than the maximum. The mask is a value between 0 and 255. Ethernet Type: To identify a packet by Ethernet Type, classify either DIX- or SNAP-encapsulated frames, or frames with an SAP less than or greater than 0xAA. For DIX- or SNAP-encapsulated frames, specify a 16-bit Ethernet type. For frames with an SAP less than or greater than 0xAA, specify an 8-bit Ethernet type. Ethernet Priority: Specify the minimum and maximum priority in the 802.1Q priority. The range is 0-7. VLAN ID: To identify a packet by VLAN ID, specify a VLAN ID. Source IP Address: To identify a packet by IP source address, specify a list of 1 to 16 address/mask combinations. Dest IP Address To classify by IP destination address, specify a list of 1 to 16 address/mask combinations. Source IP Port Low: To identify a packet by source port range, specify a list of 1 to 16 port ranges. For each range, the low value must be less than or equal to the high value. Ranges cannot overlap. NOTE: This field can be defined only if TCP or UDP are included in the IP Protocol list (see IP Protocol List above). Destination IP Port Low: To identify a packet by destination port range, specify a list of 1-16 port ranges. For each range, values can range between 1-65535, and the low value must be less than or equal to the high value. Ranges cannot overlap. NOTE: This field can be defined only if TCP or UDP are included in the IP Protocol list. IP Protocol: To identify a packet by IP protocol, specify a list of up to 16 values. Source MAC Address: To identify a packet by source MAC address, specify a list of 1 to 16 MAC addresses and masks. Masks default to FF:FF:FF:FF:FF:FF. Destination MAC Address: To identify a packet by destination MAC address, specify a list of 1 to 16 MAC addresses and masks. Masks default to FF:FF:FF:FF:FF:FF. 7. Click OK. Pre-Defined PIRs The MP.16 system comes with several pre-defined PIRs that can be used as is, edited, or used as templates for the creation of new PIRs. These pre-defined PIRs can be deleted by the administrator; if they are deleted, they are restored if the system is reset to factory defaults. The following table describes the pre-defined PIRs:
Table 3-3 Pre-Defined PIRs PIR Name Classification Fields All Cisco VoIP UL Vonage VoIP UL Cisco VoIP DL Vonage VoIP DL TCP UDP PPPoE Control No classification fields; all traffic matches Protocol Source Port Range (16,000-33,000) IP Protocol List (17) Protocol Source Port Range (5060-5061, 10000-20000) IP Protocol List (17) Protocol Source Port Range (16,000-33,000) IP Protocol List (17) Protocol Source Port Range (5060-5061, 10000-20000) IP Protocol List (17) IP Protocol List (6) IP Protocol List (17) Ethertype (type 1, 0x8863) 87 Base Station Configuration Service Class Creation Table 3-3 Pre-Defined PIRs PIR Name PPPoE Data IP ARP Expedited Forwarding Streaming Video (IP/TV) 802.1p BE 802.1p Voice 802.1p Video L2 Broadcast/Multicast Service Flow Creation Tsunami MP.16 3650 System User Guide Classification Fields Ethertype (type 1, 0x8864) Ethertype (type 1, 0x800) Ethertype (type 1, 0x806) IP TOS/DSCP (low=0x2D, high=0x2D, mask = 0x3F) IP TOS/DSCP (low=0x0D, high=0x0D, mask = 0x3F) Ethernet Priority (low=0, high=0) Ethernet Priority (low=6, high=6) Ethernet Priority (low=5, high=5) Ethernet Destination (dest = 0x80000000, mask = 0x80000000) You can create, delete, and edit up to 256 service flow classes, including those that are predefined for you (see Pre-Defined Service Flow Classes). 1. Click Service Class Creation > SF Class Figure 3-44 Service Flow Class List 2. Do one of the following:
Click Add to create a new SF Class. Click the radio button next to one of the SF Classes and click Clone to make a copy of that SF Class. Click the radio button next to one of the SF Classes and click Edit an existing SF Class. Click the radio button next to one of the SF Classes and click Delete to delete that SF Class from the list. If you are adding or cloning an SF Class, specify a unique name between 1 and 32 characters, and click Add. 3. 88 Base Station Configuration Service Class Creation Tsunami MP.16 3650 System User Guide Figure 3-45 Add Service Flow Classes Screen The Service Flow Class Configuration page will be displayed. Figure 3-46 Service Flow Class Configuration Page 4. Configure the Service Flow Class parameters:
Scheduling Type: The traffic scheduling mechanism used by the uplink or downlink. Select one of the following:
Best-Effort Service (BE): This mechanism is defined by the following QoS parameters: maximum sustained data rate and traffic priority. See below. Non Real-Time Polling Service (nrtPS): This mechanism is defined by the following QoS parameters: maximum sustained data rate, minimum reserved traffic rate, and traffic priority. See below. Real-Time Polling Services (rtPS): This mechanism is defined by the following QoS parameters: maximum sustained data rate, minimum reserved traffic rate, and maximum latency. See below. 89 Base Station Configuration Service Class Creation Tsunami MP.16 3650 System User Guide Unsolicited Grant Service (UGS): This mechanism is defined by the following QoS parameters: maximum sustained data rate, maximum latency, and tolerable jitter. See below. Service Flow Direction: Select Uplink or Downlink. QoS Parameters Maximum Sustained Data Rate: The peak information rate of the service flow. All traffic classified onto a service flow in excess of this rate is dropped. Set this parameter to unlimited, or to any value between 8 kbps and 8192 kbps. The default value is unlimited. Set to 0 for unlimited. Minimum Reserved Traffic Rate: The minimum reserved traffic rate for the service flow. Set this parameter to any value between 8 kbps and 8192 kbps. The default value is 0 (unlimited). Maximum Latency: The maximum latency between the reception of a packet by the BS or SS on its network interface and the forwarding of the packet to the RF interface. Set this parameter to any value between 5 ms and 100 ms, in increments of 5 ms. Tolerable Jitter: The maximum delay variation for the connection. Set this parameter to any value between 5 ms and 100 ms, in increments of 5 ms. Traffic Priority: The priority assigned to the service flow. Set this parameter to any value between 0 and 7, where 7 is the highest priority. 5. Click OK. Pre-Defined Service Flow Classes The MP.16 system comes with several pre-defined service flow classes that can be used as is, edited, or used as templates for the creation of new SF classes. These pre-defined classes can be deleted by the administrator; if they are deleted, they are restored if the system is reset to factory defaults. The following table describes the pre-defined service flow classes. Table 3-4 Pre-Defined Service Flow Classes Service Flow Class Name Scheduling Type Direction UL-Unlimited BE DL-Unlimited BE UL-G711 20ms VoIP UGS Unlimited Grant Best Effort Best Effort Service Uplink Downlink Uplink Max. Sustained Data Rate Unlimited Unlimited 100 kbps DL-G711 20ms VoIP UGS Unlimited Grant Service Downlink 100 kbps Min. Reserved Traffic Rate Max. Latency Tolerable Jitter Traffic Priority 0 0 20 ms 20 ms 0 0 Subscriber Station Class Creation You can create, delete, and edit up to 64 SS classes, including those that are predefined (see Pre-Defined Subscriber Station Classes). To do so, you will use the SFs and PIRs created the previous sections. 1. Click Service Class Creation > SS Class 90 Base Station Configuration Service Class Creation Tsunami MP.16 3650 System User Guide Figure 3-47 Subscriber Station Class List 2. Do one of the following:
Click Add to create a new SS Class. Click the radio button next to one of the SS Classes and click Clone to make a copy of that SS Class. Click the radio button next to one of the SS Classes and click Edit an existing SS Class. Click the radio button next to one of the SS Classes and click Delete to delete that SS Class from the list. If you are adding or cloning an SS Class, specify a unique name between 1 and 32 characters, and click Add. If you are editing an SS class, select the radio button next to the name of the Class you wish to edit, and click Edit. 3. Figure 3-48 Add Subscriber Station Classes Screen The Subscriber Station Class wizard will start, and the first of three configuration steps will be displayed. In this step, you will select Service Flows to add to the SS Class. 91 Base Station Configuration Service Class Creation Step 1: Select Service Flows Tsunami MP.16 3650 System User Guide Figure 3-49 SS Class Creation Step 1: Select Service Flows 4. Under the Available Service Flows heading, select a Service Flow and Type that are to be used for this class, and click
. To remove a service flow, select it and click the left arrow. At least one uplink and one downlink the right arrow service flow must be defined. Select a Service Flow Type, based on the following:
IPv4 ENET: Use this type when associated PIRs use at least one IP classifier and no VLAN classifiers. Ethernet classifiers are optional. IPv4 VLAN: Use this type when associated PIRs use at least one IP classifier and one VLAN classifier. ENET 802.3: Use this type when associated PIRs use only Ethernet classifiers. VLAN 802.1Q: Use this type when associated PIRs use only VLAN classifiers. 5. Click Save & Next. The Step 2: Associate PIRs with Service Flow page will be displayed. This page contains a section for each Service Flow you added in Step 1. 92 Base Station Configuration Service Class Creation Step 2: Associate PIRs with Service Flows Tsunami MP.16 3650 System User Guide Figure 3-50 SS Class Creation Step 2: Add PIRs to Service Flows 1. For each Service Flow, select a PIR, assign it a Priority level, and click the right arrow it and click the left arrow. You can add up to 32 PIRs to each Service Flow. To remove a PIR, select 2. Click Save & Next. The Step 3: Networking Parameters page will be displayed. On this page, you will configure the VLAN settings for the SS Class. 93 Base Station Configuration Service Class Creation Step 3: Networking Parameters Tsunami MP.16 3650 System User Guide Figure 3-51 SS Class Creation Step 3: Networking Parameters (Transparent Mode) 1. Select the VLAN Mode depending on Base Stations VLAN mode:
If the BS is configured for VLAN Trunk mode, the SS class can be configured for Trunk, Access, or Mixed mode. If the BS is configured for VLAN Transparent mode, the SS class can be configured for either Transparent or Access mode. 2. If the VLAN mode is set to Transparent, click Save & Finish. NOTE: The VLAN Management ID parameter has no effect when VLAN Mode is set to Transparent. This field is not configurable. 3. If the VLAN mode is set to Access, Trunk, or Mixed, see Configuring an SS Class for Access Mode or Configuring an SS Class for Trunk Mode. 94 Base Station Configuration Service Class Creation Tsunami MP.16 3650 System User Guide Configuring an SS Class for Access Mode With the VLAN mode set to Access, the following screen will be displayed:
Figure 3-52 SS Class Creation Step 3: Networking Parameters (Access Mode) In Access mode, only one VLAN ID may be specified as having access to the SS. This VLAN ID has management access. NOTE: When you move the VLAN ID to the Selected Access VLAN ID list, the VLAN Management ID field will be automatically populated with this ID. Set the following parameters and then click Save & Finish:
Selected VLAN Access ID: Select one VLAN ID from the Available VLAN ID List to serve as the Management ID. Only VLAN packets tagged with this ID will have access to and be able to manage the SS. To designate a VLAN ID as the Management ID, select the VLAN ID from Available VLAN ID List, and click the right arrow
. To designate a different VLAN ID as the Management ID, remove the current VLAN ID by clicking the left arrow, and select a different VLAN ID from the list. VLAN Priority: Priority to be given to the Selected Access VLAN ID; select a number between 0 and 7. For information on configuring the Available VLAN ID List, see VLAN ID List. 95 Base Station Configuration Service Class Creation Tsunami MP.16 3650 System User Guide Configuring an SS Class for Trunk Mode With the VLAN mode set to Trunk, the following screen will be displayed:
Figure 3-53 SS Class Creation Step 3: Networking Parameters (Trunk Mode) In Trunk mode, up to 16 VLAN IDs may be specified as having access to the SS. Additionally, one of these VLAN IDs must be designated as the VLAN Management ID for the VLAN. NOTE: The total number of VLANs and Service Flows must not exceed 20. Set the following parameters and click OK:
VLAN Management ID: Select one VLAN ID from the Selected Trunk VLAN ID List to serve as the Management ID. Only VLAN packets tagged with this ID will have management access to the SS. If the VLAN ID entered in this field is not contained in the Selected Trunk VLAN ID List, an error message will be displayed when you click OK. Selected VLAN ID List: You may add up to 16 VLAN IDs to this list. To add a VLAN ID, select the VLAN ID from Available VLAN ID List, and click the right arrow left arrow. NOTE: After clicking OK, the selected Management ID will be automatically moved to the top of the Selected Trunk
. To remove a VLAN ID from the list, select the ID and click the VLAN ID List. For information on configuring the Available VLAN ID List, see VLAN ID List. 96 Base Station Configuration Service Class Creation Tsunami MP.16 3650 System User Guide Configuring an SS Class for Mixed Mode With the VLAN mode set to Mixed, the following screen will be displayed:
Figure 3-54 SS Class Creation Step 3: Networking Parameters (Mixed Mode) In Mixed mode, one VLAN Access ID and up to 16 VLAN Trunk IDs may be specified as having access to the SS. The VLAN Access ID has management access. NOTE: When you move a VLAN ID to the Selected Access VLAN ID list, the VLAN Management ID field will be automatically populated with this ID. NOTE: The total number of VLANs and Service Flows must not exceed 20. When using Mixed mode, this number includes the Access VLAN ID as well as the Trunk VLAN IDs. Set the following parameters and click OK:
Selected Access VLAN ID: Select one VLAN ID from the Available VLAN ID List to serve as the Selected Access VLAN ID. Only VLAN packets tagged with this ID will have access to and be able to manage the SS. To designate a VLAN ID as the Access VLAN ID, select the VLAN ID from Available VLAN ID List, and click the right arrow
. To designate a different VLAN ID as the Management ID, remove the current VLAN ID by clicking the left arrow, and select a different VLAN ID from the list. VLAN Priority: Priority to be given to the Selected Access VLAN ID; select a number between 0 and 7. Selected Trunk VLAN ID List: You may add up to 16 VLAN IDs to this list. To add a VLAN ID, select the VLAN ID
. To remove a VLAN ID from the list, select the ID and click from Available VLAN ID List, and click the right arrow the left arrow. For information on configuring the Available VLAN ID List, see VLAN ID List. 97 Base Station Configuration Service Class Creation Tsunami MP.16 3650 System User Guide Pre-Defined Subscriber Station Classes The MP.16 system comes with several pre-defined SS classes that can be used as is, edited, or used as templates for the creation of new SF classes. These pre-defined classes can be deleted by the administrator; if they are deleted, they are restored if the system is reset to factory defaults. The following table describes the pre-defined SS classes. NOTE: Pre-defined SS Classes have a VLAN mode of Transparent. Table 3-5 Pre-Defined SS Classes SS Class Name Uplink Unlimited Best Effort G711 VoIP UGS G711 VoIP UGS/Unlimited BE SF Class Name(s) PIR(s) UL-Unlimited BE UL-G711 20ms UGS UL-Unlimited BE All All All Priority 0 0 0 UL-G711 20ms UGS Vonage VoIP UL Cisco VoIP UL 1 1 Downlink SF Class Name(s) PIR(s) DL-Unlimited BE DL-G711 20ms UGS UL-Unlimited BE DL-G711 20ms UGS All All All Priority 0 0 0 Vonage VoIP DL Cisco VoIP DL 1 1 98 Base Station Configuration Logging Configuration Logging Configuration Tsunami MP.16 3650 System User Guide From the Logging Configuration page, you can set the parameters for the logging functions of the BS. Figure 3-55 Logging Configuration The following logging parameters can be configured or viewed:
Filter Level: For both the volatile (stored in RAM) and non-volatile (stored in Flash), select the minimum logging level. Logging Output: Select the desired output locations:
Select Volatile Log to save the log to the RAM. Note that information stored to the RAM may be lost in the event of a power cycle. Select Non-Volatile Log to save the log to the flash. Clear Logs: Press Delete to clear the contents of the specified log. Module IDs: Select the modules for which logging should be enabled. Once logging is configured, logs can be viewed on the Logs page. 99 Base Station Configuration Management Interface Configuration Management Interface Configuration Tsunami MP.16 3650 System User Guide From the Management Interface page, you can enable or disable SNMP management. Figure 3-56 Management Interface Configuration 100 Subscriber Station Configuration Tsunami MP.16 3650 System User Guide 4 To configure local SS parameters via the web, log in to the SSs web interface. For information on configuring the SS via the CLI, see Configuration from the Subscriber Station in the Command Line Interface chapter. After logging in to the SS, you can access the following configuration pages:
System Configuration Radio Configuration Network Configuration Syslog Configuration Logging Configuration 101 Subscriber Station Configuration System Configuration System Configuration Tsunami MP.16 3650 System User Guide To access the System Configuration page, click Configuration > System. The System Configuration page allows you to set and view SS-specific MAC address, name, location, and contact information. Figure 4-1 SS System Configuration Parameters The following parameters can be configured or viewed from the System Configuration page:
System Description: A read-only description of the Subscriber Station, including software version and build information. SS MAC Address: The MAC address of the SS. System Name: The name assigned to SS. Enter a value between 1 and 255 alphanumeric characters. System Location: The location where the SS is installed. Enter a value between 1 and 255 alphanumeric characters. Contact Name: The name of the person responsible for the SS. Enter a value between 1 and 255 alphanumeric characters. Contact Phone: The telephone number of the person responsible for the SS. Enter a value between 1 and 255 alphanumeric characters. Contact Email: The email address of the person responsible for the SS. Enter a value between 1 and 255 alphanumeric characters. 102 Subscriber Station Configuration Radio Configuration Radio Configuration Tsunami MP.16 3650 System User Guide From the SS Radio configuration page, you can control the channel bandwidth and frequency, and specify a BS connection. Figure 4-2 SS Radio Parameters Configuration The following parameters may be set or viewed:
Channel Bandwidth: Select a channel bandwidth of 3.5 MHz or 7 MHz. Frequency Channel: Set the desired center frequency. BS ID: Set the specific ID of the Base Station with which the SS communicates, or set this parameter to Any to connect to any available Base Station (the default). 103 Subscriber Station Configuration Network Configuration Network Configuration Tsunami MP.16 3650 System User Guide From the SS Network configuration page, you can set the Ethernet IP address and mask, specify the default gateway, and enable/disable secondary management functionality. Figure 4-3 SS Network Configuration The following parameters may be set or viewed:
Ethernet IP Address: Enter an IP address and subnet for the units Ethernet port. The default IP address of the SS is 192.168.10.2. Ethernet IP Subnet Mask: Select a subnet mask for the units Ethernet port. The default mask is 255.255.255.0 Default Gateway: Enter an IP address to serve as the default IP gateway. Secondary Management: Use the drop-down menu to enable or disable secondary management support. See Global Positioning System (GPS) in the Base Station Configuration chapter for more information. 104 Subscriber Station Configuration Syslog Configuration Syslog Configuration Tsunami MP.16 3650 System User Guide When Secondary Management is enabled, the Syslog Server List displays the IP addresses of the Syslog servers configured on the BS. Figure 4-4 Syslog Server List 105 Subscriber Station Configuration Logging Configuration Logging Configuration Tsunami MP.16 3650 System User Guide From the Logging Configuration page, you can set the parameters for the logging functions of the SS. Figure 4-5 Logging Configuration 106 Commands on BS/SS Tsunami MP.16 3650 System User Guide 5 The following commands are available on the BS and SS:
Update to BS/SS Reboot Reset Passwords NOTE: Figures in this chapter are based on the BS. SS functionality is identical unless otherwise noted. 107 Commands on BS/SS Update to BS/SS Update to BS/SS Update via TFTP Tsunami MP.16 3650 System User Guide Use the Update page to update software images and configuration files to the unit. A TFTP server must be running and configured to point to the directory containing the file. If you do not have a TFTP server installed on your system, install the TFTP server from the Installation CD. Figure 5-1 Update via TFTP Screen The Update page contains the following parameters:
File Type: Select the proper file type. Choices include:
Config: configuration information, such as System Name, Contact Name, and so on. Image: BS/SS Image (executable program). File Name: Enter the name of the file to be downloaded (including the file extension). This file must be in the TFTP servers local root directory. TFTP Server IP Address: Enter the TFTP server IP Address. This is the IP address that will be used to point the unit to the Image file. 108 Commands on BS/SS Save Config to Server (BS Only) Save Config to Server (BS Only) Save via TFTP Tsunami MP.16 3650 System User Guide On the BS, use the Save via TFTP page to save configuration to a location external to the unit. A TFTP server must be running and configured to point to the directory containing the file. If you do not have a TFTP server installed on your system, install the TFTP server from the Installation CD. Figure 5-2 Save via TFTP Screen The Update page contains the following parameters:
File Name: Enter the name of the file to be saved (including the file extension). TFTP Server IP Address: Enter the IP Address of the TFTP server where the file is to be placed. 109 Commands on BS/SS Reboot Reboot Tsunami MP.16 3650 System User Guide Use the Reboot tab to save configuration changes (if any) and reset the unit. Note that Reset, described below, discards configuration changes. CAUTION: Rebooting the unit will cause all users who are currently connected to lose their connection to the network until the unit has completed the restart process and resumed operation. Figure 5-3 Reboot Screen 110 Commands on BS/SS Reset Reset Tsunami MP.16 3650 System User Guide Use the Reset tab to restore the unit to factory default conditions. Since this will reset the current IP address, a new IP address must be assigned. The unit will reboot automatically after this command has been issued. CAUTION: Resetting the unit to its factory default configuration will permanently overwrite all configuration changes to date. Figure 5-4 Reset to Factory Defaults Screen 111 Commands on BS/SS Passwords Passwords Tsunami MP.16 3650 System User Guide Use the Passwords page to change the management passwords for the BS/SS. If you are logged on as an administrator, you can change the administrator-level password or the user-level password. If you are logged on as a user, you can change only the user-level password. Figure 5-5 Passwords Screen 112 Tsunami MP.16 3650 System User Guide 6 Log Messages on the BS/SS See the following sections:
Logging Configuration Log Messages Logging Configuration On the BS, logging is configured on the Configure > Logging. See Logging Configuration in the Base Station Configuration chapter. On the SS, logging is configured from the Logs > Configuration page (shown here). Figure 6-1 Logging Configuration (Subscriber Station) The following logging parameters can be configured or viewed:
Filter Level: For both the volatile (temporary) and non-volatile (permanent), select the minimum logging level. Logging Output: Select the desired output locations:
113 Log Messages on the BS/SS Logging Configuration Tsunami MP.16 3650 System User Guide Select Volatile Log to save the log to the RAM. Note that information stored to the RAM may be lost in the event of a power cycle. Select Non-Volatile Log to save the log to the flash. Clear Logs: Press Delete to clear the contents of the specified log. Module IDs: Select the modules for which logging should be enabled. Once logging is configured, logs can be viewed by clicking on Monitor > Logs tab in the web interface. See Log Messages on the BS/SS for more information. 114 Log Messages on the BS/SS Log Messages Log Messages Tsunami MP.16 3650 System User Guide Log messages for both the Base Station and Subscriber Stations can be monitored by the administrator. You can view log messages for either the non-volatile or the volatile memory. Figure 6-2 Non-Volatile Message Log Page Common Log Messages The following log messages are supported on both the Subscriber Station and the Base Station:
Log Message Invalid HTTP Login Invalid SNMP Community Invalid CLI Login Base Station Log Messages The following log messages are supported in the Base Station:
Log Message Subscriber station xx:xx:xx:xx:xx:xx successfully entered the network Subscriber station xx:xx:xx:xx:xx:xx authorization failure Subscriber station xx:xx:xx:xx:xx:xx exited the network Subscriber station xx:xx:xx:xx:xx:xx adapted uplink/downlink from y to z. (e.g., y,z = BPSK-1/2) No response from Radius Server Service Flow xxxx successfully activated Subscriber station xx:xx:xx:xx:xx:xx power adjusted by # dB Subscriber Station Log Messages The following log messages are supported at the Subscriber Station:
Log Message Subscriber station adjusted power by # dB Service Flow xxxx successfully activated Subscriber station lost link to BSID xx:xx:xx:xx:xx:xx Subscriber station successfully connected to BSID xx:xx:xx:xx:xx:xx Subscriber station requesting downlink adaptation from y to z Severity Warning Warning Warning Severity Informational Warning Informational Informational Alert Informational Informational Severity Informational Informational Alert Informational Informational 115 Monitoring the BS and SS Tsunami MP.16 3650 System User Guide 7 Statistics for both the Base Station and Subscriber Stations can be monitored by the administrator. Base Station Monitoring BS Ethernet Statistics BS MAC Statistics Service Flow Statistics Registered SS Statistics System Inventory GPS Status Subscriber Station Monitoring SS Ethernet Statistics SS MAC Statistics SS Service Flow Statistics 116 Monitoring the BS and SS Base Station Monitoring Base Station Monitoring BS Ethernet Statistics Tsunami MP.16 3650 System User Guide Figure 7-1 BS Ethernet Statistics The BS displays the following interface statistics:
Unicast and multicast packets received Unicast and multicast packets transmitted BS MAC Statistics Figure 7-2 BS MAC Statistics The BS displays the following MAC statistics:
Packets transmitted Packets received Number of CRC errors Number of bad HCSs Number of missed bursts 117 Monitoring the BS and SS Base Station Monitoring Service Flow Statistics Tsunami MP.16 3650 System User Guide Figure 7-3 Service Flow Statistics This screen provides information on each Service Flow that has been provisioned (whether active or inactive) to SSs. Arrows indicate whether the SF is uplink or downlink. The following statistics are displayed for each SF:
Direction and State: The colored arrows on the page indicate the direction and state of each SF. Subscriber Station: The MAC address of the SS using the Service Flow. SF Name: The name of the Service Flow. SFID: The Service Flows ID number CID: The connection ID (if connected) Pkts: The number of packets sent or received (active flows only). 118 Monitoring the BS and SS Base Station Monitoring Registered SS Statistics Tsunami MP.16 3650 System User Guide Figure 7-4 SS Statistics Screen This screen provides information on each SS currently registered with the BS. Select the required SS and click the Statistics button. The following page is displayed:
Figure 7-5 SS Statistics Detail Screen This page contains information about the following:
Uplink modulation Downlink modulation Elapsed time since network entry Average RSSI 119 Tsunami MP.16 3650 System User Guide Monitoring the BS and SS Base Station Monitoring Average SNR Uplink packets Downlink packets Basic CID Primary CID System Inventory The System Inventory page provides information on the components of the system, including hardware, software, and radio components. Figure 7-6 System Inventory Screen GPS Status The GPS Status page displays information related to GPS functionality. 120 Monitoring the BS and SS Subscriber Station Monitoring Subscriber Station Monitoring SS Ethernet Statistics Tsunami MP.16 3650 System User Guide Figure 7-7 SS Ethernet Statistics The SS displays the following statistics on a per-interface basis. Unicast and multicast packets transmitted Unicast and multicast packets received SS MAC Statistics Figure 7-8 SS MAC Statistics The following statistics can be displayed for the SS MAC:
Packets transmitted Packets received CRC errors Bad HCSs Downlink RSL 121 Monitoring the BS and SS Subscriber Station Monitoring Average SNR Current uplink and downlink modulations Elapsed time since network entry SS Service Flow Statistics Tsunami MP.16 3650 System User Guide Figure 7-9 SS Service Flow Statistics This screen provides information on each Service Flow that has been provisioned (whether active or inactive) to the SS. Arrows indicate whether the SF is uplink or downlink. The following statistics are displayed for each SF:
Direction and State: The colored arrows on the page indicate the direction and state of each SF. Subscriber Station: The MAC address of the SS using the Service Flow. Service Flow Name: The name of the SF. SFID: The Service Flows ID number CID: The connection ID (if connected) Pkts: The number of packets sent or received (active flows only). 122 Technical Specifications Please see the following sections:
Part Numbers Product Specifications Hardware Specifications Part Numbers Base Station Part Number Tsunami MP.16 3650 System User Guide B Description 3650-B00-WLD0 Tsunami MP.16 3650 Base Station with external type-N antenna connector Subscriber Station Part Number 3650-S00-WLD0 3650-S00-WLD1 Base Station Antennas Part Number 3336-A00-360 3338-A00-060 3338-A00-90 3338-A00-120 Tsunami MP.16 3650 Subscriber Station with external type-N antenna connector Tsunami MP.16 3650 Subscriber Station with integrated antenna Description Description 8 dBi Omni-Directional Antenna 60 Sector Antenna 90 Sector Antenna 120 Sector Antenna Subscriber Station Antennas Part Number 3437-A00-001 18 dBi Panel Antenna Description Power Injector Part Number Description 69823 Spare MP.16 32 Watt Power Injector Kit Accessories/Spare Kits Part Number 5054-SURGE 70251 Surge Arrestor for 5 GHz, Standard-N Female to Female PoE (Power over Ethernet) Surge Arrestor Description 165 Technical Specifications Product Specifications: Features Product Specifications Features Tsunami MP.16 3650 System User Guide Feature WiMAX Compliance Duplexing Mode Channel Bandwidth Maximum MAC Addresses per Sector and CPE Maximum Service Flows Per Sector and CPE Maximum VLANs Per Sector and CPE Center Channel Frequency Resolution NLOS and Interference Mitigation Features Modulation Frame Duration FEC Description 3.300 GHz to 3.500 GHz TDD 3.5 MHz to 7 MHz 8192/8192 Base Station supports up to 256 Service Flow Classes, 512 Packet Identification Rules, and 64 Subscriber Station Classes. 16 Service Flows are supported in each Subscriber Station Class. 256 VLAN IDs per sector supported. 16 VLAN IDs supported per CPE. 1 KHz channel raster OFDM 256 FFT, adaptive modulation, FEC OFDM modulation, 256 FFT points: BPSK, QPSK, 16QAM, 64QAM 5, 10, 20 ms Convolutional coding: 1/2, 2/3, 3/4 166 Technical Specifications Radio Performance: Features Radio Performance Tsunami MP.16 3650 System User Guide Channel Bandwidth 3.5 MHz 7 MHz Modulation/FEC Rx Sensitivity
(10-6) Minimum C/I Spectral Efficiency BPSK - 1/2 QPSK - 1/2 QPSK - 3/4 16QAM - 1/2 16QAM- 3/4 64QAM- 2/3 64QAM- 3/4 BPSK - 1/2 QPSK - 1/2 QPSK - 3/4 16QAM - 1/2 16QAM- 3/4 64QAM- 2/3 64QAM- 3/4
-95 dBm
-92 dBm
-90 dBm
-87 dBm
-84 dBm
-80 dBm
-78 dBm
-92 dBm
-89 dBm
-87 dBm
-84 dBm
-81 dBm
-77 dBm
-75 dBm 4.5 dB 6.6 dB 8.9 dB 11.9 dB 15.2 dB 19.3 dB 21.3 dB 4.5 dB 6.6 dB 8.9 dB 11.9 dB 15.2 dB 19.3 dB 21.3 dB 0.5 bps/Hz 1 bps/Hz 1.5 bps/Hz 2 bps/Hz 3 bps/Hz 4 bps/Hz 4.5 bps/Hz 0.5 bps/Hz 1 bps/Hz 1.5 bps/Hz 2 bps/Hz 3 bps/Hz 4 bps/Hz 4.5 bps/Hz Burst Data Rate, Mbps Tg/Tb = 1/16 1.4 Mbps 2.8 Mbps 4.2 Mbps 5.6 Mbps 8.5 Mbps 11.3 Mbps 12.7 Mbps 1.4 Mbps 2.8 Mbps 4.2 Mbps 5.6 Mbps 8.5 Mbps 11.3 Mbps 12.7 Mbps 167 Technical Specifications Hardware Specifications: Environmental Specifications Hardware Specifications Environmental Specifications Tsunami MP.16 3650 System User Guide Feature Specification Operating Temperature Storage Temperature Operating Altitude Water Tightness Storage and Transit Altitude Wind Humidity Dust Salt Transit and Vibration Power Specifications Feature Outdoor Radio Unit (BS/SS)
-40 to +60 C
-55 to +85 C Up to 15,000 ft. IPx5 protection in accordance with IEC 60529 and UL50 Up to 40,000 ft. Up to 115 mph Up to 100%
IPx6 protection in accordance with IEC 60529 Immune Per MIL-STD-810, methods 514.5 and 516 Indoor Power Injector 0 to +40 C
-20 to +85 C Up to 15,000 ft. IPx5 protection in accordance with IEC 60529 and UL50 Up to 40,000 ft. NA Up to 95%, non-condensing NA NA NA Specification Outdoor Radio Unit (BS/SS) Input Voltage Range Output Voltage and Current Input Connector Power Consumption (Typical) 42 to 60 VDC NA RJ45 BS: Less than 12 Watts SS: Less than 10 Watts Size and Weight Specifications Indoor Power Injector 90 to 260 VAC, 47 to 63 Hz 48 VDC up to 0.67 AMPs 3-conductor male Up to 32 Watts total power output Feature Outdoor Radio Unit (BS/SS) Indoor Power Injector Specification Weight Dimensions (Packaged) 5.3 lbs 14.57 x 13.70 x 8.19 in
(370 x 348 x 208 mm) Dimensions (Unpackaged: Model 3650 SS/BS) 10.5 x 10.5 x 3.25 in
(267 x 267 x 83 mm) 12.6 x 12.6 x 3.5 in
(320 x 320 x 89 mm) Dimensions (Unpackaged: Model 3650i SS) Integrated Antenna (SS only) Feature Gain Polarization Horizontal Beamwidth 18 dBi Horizontal or vertical 18 Specification 2.7 lbs 5.12 x 3.62 x 2.64 in
(130 x 92 x 67 mm) 168 Technical Specifications Hardware Specifications: Antenna Port Tsunami MP.16 3650 System User Guide Feature Vertical Beamwidth Azimuth/Elevation Cross Polarization Return Loss Antenna Port Feature Connector Return Loss, BS Return Loss, Antenna Specification 17 Meets EN 302 085 TS2 Meets EN 302 085 TS2 14 dB Specification N-Female, 50 Ohms
-15 dB, maximum
-10 dB, maximum Data Communication Port Feature Standard Connector Compliance Max Packet Size Specification 10/100 Base-TX Ethernet, manual/auto negotiate, half/full duplex RJ45 802.3, 802.3u, IPv4 Up to 1600 bytes Serial Configuration Port Feature Connector RJ45 Specification 169 Command Line Interface This chapter contains information on the following topics:
CLI Overview Document Conventions Basic Functionality CLI Rules Commands Configuration from the Base Station System Parameters Base Station Parameters MAC Parameters Radio Parameters VLAN ID List Subscriber Station List Service Class Creation Subscriber Station Classes Service Flows Packet Identification Rules Logging Configuration Trap Host Parameters Management Interface Parameters Configuration from the Subscriber Station Subscriber Station Device Configuration Radio Configuration Logging Configuration Monitoring the BS and SS Software Version Network Status (SS only) Base Station Statistics Subscriber Station Statistics Log Messages Tsunami MP.16 3650 System User Guide A 123 Command Line Interface CLI Overview: Document Conventions CLI Overview Document Conventions Tsunami MP.16 3650 System User Guide The following text conventions are used in this chapter:
Computer prompts are shown as constant width type. For example: MP16>
NOTE: The root prompt is represented globally as MP16. Depending on your systems name, your system may use a different root prompt. Information that you input as shown is displayed in bold constant width type. For example:
MP16> set ipaddr 10.0.0.12 Basic Functionality Navigation and Special Keys The CLI supports the use of special key combinations and arrow keys for navigation. The supported special keys are defined below:
Key Combination Description Backspace Delete CtrlA CtrlE CtrlF CtrlB CtrlD CtrlU Ctrl-K Ctrl-W Ctrl-T CtrlP CtrlN Tab
Command History Delete previous character Delete next character Move cursor to beginning of line Move cursor to end of line Move cursor forward one character Move cursor back one character Delete the character the cursor is on Delete all text to the left of the cursor Delete to end of line Delete previous word Transpose previous character Go to the previous line in the history buffer (see Command History) Go to the next line in the history buffer (see Command History) Complete the command line (see Command Line Completion) List available commands (see Command Line Listing) You can access previously-executed commands in the history buffer. Commands in the history buffer can be accessed by using the following special keys:
Ctrl-P (previous line in history buffer) Ctrl-N (next line in history buffer) Up arrow (previous line in history buffer) Down arrow (next line in history buffer) Command Line Completion When you press the tab key while typing a command or argument at the prompt, the command or argument name will be completed as the one that most closely matches what has been typed. Command or argument completion will only be 124 Command Line Interface CLI Overview: CLI Rules Tsunami MP.16 3650 System User Guide possible if there is no ambiguity, and if there is a match to what has been typed. If more than one command or argument matches what has been typed, a list of possible matches will be displayed. Command Line Listing This command can be used in a number of ways to display available commands and parameters. The following table lists each operation and provides a basic example. Operation Display the Command List Display commands that start with specified letters Display next possible parameters or commands Basic Example MP16>?
MP16>c?
MP16>configure ?
MP16>configure s?
CLI Rules Parameter Groupings For ease of configuring MP.16 products, the parameters have been logically grouped. Parameter tables for each group contain the following information for each object:
Name: Parameter, group, or table name Type: Data type Value: Value range and default value, if any Access: Access type R = Read Only (can only be viewed) RW = Read-Write (can be set or viewed) W = Write Only (for passwords and security-sensitive objects) Parameter: Parameter name as used in the CLI Entering Values Although the data type of a parameter may be Integer, in order for the CLI to interpret values correctly, enter the provided alphanumeric value whenever possible. Entering Strings String objects are supported by MP.16 devices; a string delimiter is required for the strings to be interpreted correctly by the command line parser. In this implementation, the single quote () or double quote () character is to be used at the beginning and at the end of any string that contains spaces. For example:
set sysname MP 16 set sysname MP 16 set sysname MP16 Quotes required Quotes required No quotes required Rebooting Some parameter values change only when the unit is rebooted. In these cases, the CLI warns you that a reboot is required for the change to take effect. 125 Command Line Interface CLI Overview: Commands Conventions Tsunami MP.16 3650 System User Guide PIR Class, SF Class and SS Class Names All the names are case-sensitive. When you create names with a combination of uppercase and lowercase characters, you must use the same combination when configuring or deleting the PIR Class, SF Class, and SS Classes. Interface Addressing The following conventions are to be used during configuration for addressing the interfaces. These conventions apply to both the SS and the BS. rf0: Wireless interface enet0: Ethernet interface MAC Address Format When specifying the MAC address in a command, the format can be one of the following:
xx-xx-xx-xx-xx-xx xx:xx:xx:xx:xx:xx Commands Commands affect the units behavior and allow you to configure parameters and tables. After entering commands (and parameters/arguments, if any) press the Enter key to execute the Command Line. The commands listed below are described in more detail in the following subsections:
Add Command: Adds PIRs, SF Classes, Subscriber Stations, SS Classes, and VLAN IDs Configure Command: Allows configuration access to a group of parameters, packet identification rule, or service flow Delete Command: Deletes PIRs, SF Classes, Subscriber Stations, SS Classes, and VLAN IDs Download Command: Transfers files from the TFTP server to the unit Exit Command: Disconnects and closes the current CLI session Passwd Command: Changes the password used to access the CLI Reboot Command: Signals the unit to reboot after a specified number of seconds Reset Command: Resets the unit to factory default Set Command: Changes parameter values. This command is only available from the configure prompt; it not available from the root prompt. (See Configure Command.) Show Command: Views parameter and statistical values Upload Command: Transfers files from the unit to the TFTP server Add Command Use the add command from the root prompt on the BS to add PIRs, Service Flows, Subscriber Station Classes, authorized SSs, Syslog Servers, TFTP configuration information, Trap Hosts, and VLAN ID List entries. Valid syntax for the add command is as follows:
Command add pir <PIR name>
add sfclass <SF Class name>
add ssclass <SS Class name>
add ss <SS MAC address>
add sysloghost <IP Address>
Results Adds a Packet Identification Rules Adds a Service Flow Class Adds a Subscriber Station Class Adds an authorized Subscriber Station Adds a Syslog Server to the Syslog Server List 126 Command Line Interface CLI Overview: Commands Command Tsunami MP.16 3650 System User Guide Results add tftpconf <Hardware ID>
add traphost <IP Address>
add vlantbl <VLAN ID>
add vlanid <value>
Adds a Secondary Management TFTP parameters for a specific hardware ID Adds a Trap Host to the Trap Host list Adds a VLAN ID to the VLAN ID List Adds a VLAN ID to an SS or SS Class configuration when VLAN mode is set to Trunk. This command is only available from the SS or SS Class configure prompts; it not available from the root prompt. See Configure Command. View the results of the add command from the root prompt as follows:
Command show pir show pir <PIR name>
show sfclass show sfclass <SF Class name>
show ssclass show ssclass <SS Class name>
show ss show ss <SS MAC address>
show sysloghost show sysloghost <IP Address>
show tftpconf show tftpconf <Hardware ID>
show traphost show traphost <IP Address>
show vlantbl show vlantbl <VLAN ID>
Results Displays a list of all Packet Identification Rules Displays all configured parameters for a particular PIR Displays a list of all Service Flow Classes Displays all configured parameters for a particular Service Flow Class Displays a list of all SS Classes Displays all configured parameters for a particular SS Class Displays a list of all authorized Subscriber Stations Displays all configured parameters for a particular authorized Subscriber Station Displays a list of all Syslog Servers Displays all configured parameters of a particular Syslog Server Displays a list of all configured hardware IDs Displays all configured parameters of a particular configured hardware ID Displays a list of all configured Trap Hosts Displays all configured parameters of a particular Trap Host Displays a list of all VLAN IDs in the VLAN ID List. Displays all configured parameters for a particular VLAN ID NOTE: Also see Service Class Creation for information on lists of pre-defined PIRs, SS Classes, and Service Flows. Once PIRs, SF Classes, SS Classes, SSs, Syslog Hosts, TFTP hardware IDs, and Trap Hosts are added, use the Configure Command to set and show parameters specific to each. As the VLAN table has no configurable parameters, it is not executable with the configure command. Configure Command Use the configure command from the root prompt to access configuration parameters related to a particular group. For example, executing configure with system allows the user to configure system parameters. The root prompt changes based on the configure command, as follows:
MP16> configure system MP16(system)>
To exit the configure prompt and return to the root prompt, use the exit command or press CTRL-Z. Valid syntax for the configure command is as follows:
Command configure bs Access local Base Station parameters (Base Station only). Result 127 Command Line Interface CLI Overview: Commands Tsunami MP.16 3650 System User Guide Command Result Access logging parameters (Base Station only). Access Base Station MAC parameters (Base Station only). Access Packet Identification Rule parameters (Base Station only). Access Base Station radio parameters (Base Station only). Access Service Flow parameters (Base Station only). configure log configure mac configure pir <PIR name>
configure radio configure sfclass <Service Flow Class Name>
configure ss <MAC Address> On the BS, access parameters for an authorized Subscriber Station. configure ssclass
<Subscriber Station Class Name>
configure syslog configure sysloghost <IP Address) configure system configure tftpconf
<hardware ID>
configure traphost <IP Address>
Access configuration parameters related to the MP.16 system (Base Station only). Configure the Secondary Management TFTP parameters of the specified hardware ID (Base Station only). Configure the parameters of the specified Trap host (Base Station only). Enable or disable Syslog functionality (Base Station only). Configure the parameters of the specified Syslog server (Base Station only). On the SS, configure local SS parameters. Access Subscriber Station class parameters (Base Station only). Delete Command Use the delete command to delete configured PIRs, SF Classes, SS Classes, authorized SSs, and VLAN IDs. Valid syntax for the delete command is as follows:
Command delete pir <PIR name>
delete sfclass <SF Class name>
delete ss <SS MAC address>
delete ssclass <SS Class name>
delete sysloghost <IP Address) delete tftpconf <hardware ID>
delete vlantbl <VLAN ID>
Results Deletes a Packet Identification Rules (PIR) Deletes a Service Flow Class Deletes an authorized Subscriber Station Deletes a Subscriber Station Class Configure the parameters of the specified Syslog server. Delete a configured hardware ID for Secondary Management. Deletes a VLAN ID from the VLAN ID List Download Command The download command has different effects on the BS and the SS:
On the SS: the download command is used to download an image from a specified TFTP server. On the BS, the download command is used to download an image file or a configuration file from a specified TFTP server. To transfer a file from the TFTP server to the unit:
download <TFTP Server IP Address> <path or filename> <file type>
where:
<TFTP IP Address> is the IP address of the configured TFTP server
<path or filename> is the filename or path and filename of file to be downloaded 128 Command Line Interface CLI Overview: Commands Tsunami MP.16 3650 System User Guide NOTE: If the file is located in the TFTP root directory, you do not need to enter a path. However, if the file is located in a sub-level of the TFTP directory, enter the entire path, beginning with a back slash (\) and containing both the path and the file name.
<file type> is one of the following:
config: configuration file image: compressed or FPGA image file Examples:
>download 135.85.199.10 software_image001.bin image
>download 135.85.199.10 \config\software_image.bin config Passwd Command Use the passwd command to change the password used to access the CLI. Administrators can reset the password for themselves or for users. NOTE: If you are logged on as an administrator, you can change your own password or user-level passwords. If you are logged on as a user, you can change only your own password. To change the password, enter the following command:
MP16>passwd <old password> <new password> <new password>
For an administrator to change the users password, enter the following command:
MP16>passwd user <old password> <new password> <new password>
Enter the new password twice to ensure no mistake was made when specifying the new password. If you forget the CLI password, there is no way to retrieve it from the unit and the CLI cannot be accessed. In this case, the unit must be reset to factory defaults. The default password for the CLI is public. The passwd command is available from the root prompt. Use the reboot command from the root prompt to signal the unit to reboot immediately. Reboot Command MP16>reboot Reset Command Use the reset command from the root prompt to reset the unit to factory defaults or to reset statistics and logs. Valid syntax for the reset command is as follows:
Command reset defaultcfg reset stnstatreset reset log Results Resets the unit to factory default configuration. Resets the station statistics. Resets the log. Set Command Use the set command to change parameters in groups or tables. This command is only available from the configure prompt; it not available from the root prompt. (See Configure Command.) To set parameters, first access the configure prompt for the group to which the parameter belongs:
MP16>configure <group name>
129 Command Line Interface CLI Overview: Commands Tsunami MP.16 3650 System User Guide Then enter the set command from the configure prompt:
MP16 (group name)>set <parameter 1> <value 1> . <parameter N> <value N>
For example, to set the system name:
MP16>configure bs MP16(bs)> set sysname MP16 location office In the above example, the system name and location parameters are being modified. NOTE: You may also set parameters in a single step by entering the configure and set commands in one command line from the root prompt, as follows:
configure bs set sysname MP16 location office Show Command Use the show command from the root or the configure prompt to display the values of parameters or table entries, and to view statistics and diagnostic tools. The valid syntax for the show command is as follows:
Command Result Displays a list of showable groups and statistics. Displays all configured parameters in a group Displays all configured parameters in a group or table, or shows statistics. Displays a list of all PIRs. Displays configured parameters for a particular PIR. Displays a list of all SS Classes. show ?
show show <statistics, group, or table name>
show pir show pir <PIR name>
show ssclass show ssclass <SS Class name> Displays configured parameters for a show sfclass show sfclass <SF Class name> Displays configured parameters for a show sysloghost show sysloghost <IP Address> Displays all configured parameters of a show sysinvmgmt show tftpconf show tftpconf <Hardware ID> Displays all configured parameters of a show traphost show traphost <IP Address>
particular SF Class. Displays a list of all Syslog Servers particular SS Class. Displays a list of all SF Classes. particular configured hardware ID Displays a list of all configured Trap Hosts Displays all configured parameters of a particular Trap Host particular Syslog Server Displays hardware and software components of the BS or SS Displays a list of all configured hardware IDs BS (root prompt) BS (root prompt) BS and SS (root prompt) BS (root prompt) BS (root prompt) Availability BS and SS (root prompt and configure prompt) BS and SS (configure prompt only) BS and SS (root prompt and configure prompt) BS (root prompt) BS (root prompt) BS (root prompt) BS (root prompt) BS (root prompt) BS (root prompt) BS and SS (root prompt) BS (root prompt) For information on statistics and diagnostics viewable with the show command, see Monitoring the BS and SS. 130 Command Line Interface CLI Overview: Commands Tsunami MP.16 3650 System User Guide Upload Command Use the upload command from the root prompt to transfer the configuration file from the Base Station to the TFTP server. To upload a configuration file from the BS to the TFTP server, use the following syntax:
MP16>upload <TFTP server address> <path or filename>
NOTE: If the file is located in the TFTP root directory, you do not need to enter a path. However, if the file is located in a sub-level of the TFTP directory, enter the entire path, beginning with a back slash (\) and containing both the path and the file name. For example:
MP16>upload 135.85.199.10 config.bin MP16>upload 135.85.199.10 \config\config.bin Exit Command Use the exit command as follows:
From the root prompt: disconnect and close the CLI. From the configure prompt: return to the root prompt. NOTE: Pressing CTRL-Z will also exit from a configuration prompt and return to the root-level prompt. 131 Command Line Interface Configuration from the Base Station: System Parameters Configuration from the Base Station Tsunami MP.16 3650 System User Guide Log into the Base Station and use the add, delete, set, and show commands to set or view parameters associated with the following groups/tables:
System Parameters: Configure parameters affecting the MP.16 system as a whole. Parameters include Broadcast Bandwidth Control and Default Gateway. Base Station Parameters: Configure Device, Base Station ID, Net Entry Mode, IP Addresses and Masks, Ethernet Interface parameters, Bridging parameters, and VLAN Mode/Management ID parameters. MAC Parameters: Configure MAC parameters Radio Parameters: Configure Radio, Uplink Burst Profile, and Downlink Burst Profile parameters VLAN ID List Subscriber Station List Service Class Creation Subscriber Station Classes Service Flows Packet Identification Rules Logging Configuration Trap Host Parameters Management Interface Parameters System Parameters The parameters that affect the system as a whole are grouped under System. To configure the parameters under the System group, you must get into the System configuration prompt, which is done by entering the following command:
MP16>configure system The prompt will change to:
MP16(system)>
From the system configuration prompt, you can show or set parameters from the following groups:
Broadcast Bandwidth Control Default Gateway Broadcast Bandwidth Control Name Broadcast Bandwidth Control Default Gateway Type Broadcast Bandwidth Control TBD Values Access RW Parameter bcastbwctrl Name Type Values Gateway IP Address IP Address User defined Access RW Parameter dfltgateway 132 Command Line Interface Configuration from the Base Station: Base Station Parameters Base Station Parameters Tsunami MP.16 3650 System User Guide Parameters that affect the Base Station only are grouped under Base Station. To configure the parameters under the Base Station group, you must get into the Base Station configuration prompt, which is done by entering the following command:
MP16>configure bs The prompt will change to:
MP16(bs)>
From the bs configuration prompt, you can show or set parameters in the following categories:
Base Station Device Parameters SS Authentication Networking VLAN Mode/Management ID Static IP Routes Base Station Device Parameters Name Base Station ID Type MAC Address Name Display String Location Display String Contact Name Display String Contact Email Display String Contact Phone No. Display String Current Date and Time* Display String Up Time
* These values will reset to default upon unit reboot. Time Ticks SS Authentication Name Net Entry Mode Type Integer Default SS Class Display String Networking Name IP Address/Mask Maximum Multicast Downlink Type IP Address Integer Maximum VLAN Multicast Downlink Integer Access RW Values 48 bits
(default = 00:00:00:00:01) 1 255 alphanumeric characters RW 1 255 alphanumeric characters RW 1 255 alphanumeric characters RW 1 255 alphanumeric characters RW 1 255 alphanumeric characters RW YYYY:MM:DD:HH:MM 0 65535 R/W*
R Parameter bsid sysname location contact emailid phone datetime*
sysuptime Values unrestricted (default) int ext Any defined SS Class Access Parameter RW RW accessmode dfltss Values Access Parameter Valid IP address Unlimited 8 - 8192 Kbps (in multiples of 8 kbps) Unlimited 8 - 8192 Kbps (in multiples of 8 kbps) RW RW RW ipaddr maxmcastdl maxvlanmcastdl 133 Command Line Interface Configuration from the Base Station: Base Station Parameters Tsunami MP.16 3650 System User Guide Name Ethernet Speed Type Integer Repeating Mode Integer Values 10fullduplex 10halfduplex 100fullduplex 100halfduplex Auto enable disable (default) Access Parameter RW speed RW repeating To set the IP Address and Mask:
MP16>configure bs MP16(bs)>set ipaddr <interface> <ipaddress> <mask>
where <interface> is either Ethernet (enet0) or Wireless (rf1). To set the maximum multicast downlink or maximum VLAN multicast downlink:
MP16>configure bs MP16(bs)>set maxmcastdl <value> or set maxvlanmcastdl <value>
To set the Ethernet speed:
MP16>configure bs MP16(bs)>set speed enet0 <value>
VLAN Mode/Management ID Name VLAN Mode*
Type Integer Values Access Parameter RW vlanmode transparent trunk 1 - 4095 0-7 Management VLAN ID*
Management Priority
* When setting the BS to Trunk mode, you must also configure the Management VLAN ID that will be used to manage the BS. The Manage-
ment VLAN ID must be one of the VLAN IDs configured in the VLAN ID List. When you set the BS to Trunk mode, your CLI session will be terminated (stop responding). Reconnect to the CLI through a VLAN switch continue BS configuration. mgmtvlan mgmtpriority Integer Integer RW RW To set the VLAN mode to Transparent:
MP16>configure bs MP16(bs)>set vlanmode transparent To set the VLAN mode to Trunk:
MP16>configure bs MP16(bs)>set vlanmode trunk mgmtvlan <VLAN ID> mgmtpriority <0-7>
Static IP Routes NOTE: Static Routes are configured using the add command. Name Static IP Route Type Values Access Parameter iproute To add a static IP route:
MP16>configure bs MP16(bs)>add iproute <network> <mask> <gateway>
134 Tsunami MP.16 3650 System User Guide Command Line Interface Configuration from the Base Station: Base Station Parameters where:
<network> is the IP address of the destination network
<mask> is the subnet mask of the destination network
<gateway> is the IP address of the destination gateway RADIUS Configuration The following parameters may be viewed or configured:
Type Group IP Address IP Address of RADIUS Server RW R Values Access Parameter Name Radius RADIUS Server IP Address RADIUS Server Destination Port Number RADIUS Server Shared Secret RADIUS Server Response Time Maximum retransmissions to the Server RADIUS Server Status Integer 1000-65536 Display String 1 - 64 characters Integer Integer Integer 1 - 10 (seconds) 0 - 4 enable disable RW RW RW RW RW radius ipaddr port ssecret responsetm maxretx status To configure the RADIUS client on the BS, the IP address, shared secret, and status are required. All other parameters are optional:
MP16>configure bs MP16(bs)>set radius ipaddr <IP address> ssecret <password> status <enable/disable>
135 Command Line Interface Configuration from the Base Station: MAC Parameters MAC Parameters Tsunami MP.16 3650 System User Guide The parameters that affect the BS MAC are grouped under mac. To configure the parameters under the MAC group, you must get into the MAC configuration prompt by entering the following command:
MP16>configure mac The prompt will change to:
MP16(mac)>
From the mac configuration prompt, you can show or set the following parameters:
Name Frame Duration Type Integer DCD Interval*
UCD Interval Integer Integer Initial Ranging Interval Integer AK Lifetime TEK Lifetime Integer Integer Frame Synchronization Mode Downlink Percentage**
Integer Integer Cyclic Prefix Integer32 GPS Sync Integer Values Access Parameter 5 10 (default) 20 100 - 10000 milliseconds Default: 500 100 - 10000 milliseconds Default: 500 20 - 2000 milliseconds Default: 200 1800 - 604800 seconds Default: 43200 seconds 1800 - 604800 seconds Default: 43200 seconds independent 10% - 90% in steps of 1%
Default: 50%
1/32 1/16 1/8 1/4 enable disable RW RW RW RW RW RW RW RW R framedurcode dcdinterval ucdinterval initrnginterval aklifetime teklifetime framesyncmode dnlinkpercent cycprefix RW GPSSyncEnable
* Time between transmission of DCD messages. Time between transmission of UCD messages. Time between Initial Ranging regions assigned by the BS.
**This parameter sets the downlink/uplink boundary of the TDD frame by setting the percentage of bandwidth allocated to the downlink. Set the downlink percentage to a value between 10%-90% depending on the frame duration (see the following table). The remainder will be allocated to the uplink. Frame Duration Minimum Downlink Percentage Maximum Downlink Percentage 5 ms 10 ms 20 ms Radio Parameters 40%
20%
20%
50%
70%
70%
The parameters that affect the BS radio are grouped under radio. To configure the parameters under the radio group, you must get into the radio configuration prompt by entering the following command:
MP16>configure radio 136 Command Line Interface Configuration from the Base Station: Radio Parameters Tsunami MP.16 3650 System User Guide The prompt will change to:
MP16(radio)>
From the radio configuration prompt, you can show or set parameters in the following categories:
Radio Parameters Downlink Burst Profile Table Uplink Burst Profile Table Radio Parameters Name Type Channel Bandwidth Integer 3.5 7 Values Access Parameter RW chbandwidth Center Frequency Integer Transmit Power Integer Downlink Burst Profile Table Uplink Modulation RW RW 3650000 - 3675000
(in steps of 250) Default: 36850365000 5 - 21 dBm (in steps of 1 dBm) Default: 21 dBm See Downlink Burst Profile Table See Uplink Burst Profile Table centerfreq txpower See Downlink Burst Profile Table See Uplink Burst Profile Table Downlink Burst Profile Table You can enable/disable each modulation type in the Downlink Burst Profile Table. Name Type Values Downlink Burst Profile Table Modulation Type*
Integer Integer Status Integer bpsk_1_2 qpsk_1_2 qpsk_3_4 qam16_1_2 qam16_3_4 qam64_2_3 qam64_3_4 enable (default) disable Access Parameter dnlinkburstprofile feccodetype R R RW status
* The modulation type is the index to this table. See example. To enable/disable an entry in the Downlink Burst Profile Table:
MP16>set dnlinkburstprofile feccodetype <modulation type> status <enable/disable>
Uplink Burst Profile Table You can enable/disable each modulation type in the Uplink Burst Profile Table. Name Uplink Burst Profile Table Type Integer Values Access R Parameter uplinkburstprofile 137 Command Line Interface Configuration from the Base Station: Radio Parameters Tsunami MP.16 3650 System User Guide Name Type Modulation Type*
Integer Status Integer Values bpsk_1_2 qpsk_1_2 qpsk_3_4 qam16_1_2 qam16_3_4 qam64_2_3 qam64_3_4 enable (default) disable Access Parameter R feccodetype RW status
* The modulation type is the index to this table. See example. To enable/disable an entry in the Uplink Burst Profile Table:
MP16>set uplinkburstprofile feccodetype <modulation type> status <enable/disable>
138 Command Line Interface Configuration from the Base Station: VLAN ID List VLAN ID List Tsunami MP.16 3650 System User Guide All VLAN IDs to be used by the BS and associated SSs must be stored in the VLAN ID List. Up to 256 individual VLAN IDs may be stored in this list. NOTE: See VLANs in the Base Station Configuration chapter for an overview of VLAN functionality in the MP.16 system. Use the add and delete commands from the root prompt to add entries to or remove entries from the VLAN ID List table:
MP16>add vlantbl <VLAN ID>
where <vlanid> is the ID of the VLAN you wish to add. To view all VLAN IDs in the table:
MP16>show vlantbl To delete entries in the vlan table, MP16>delete vlantbl <vlanid> (deletes a particular VLAN) MP16>delete vlantbl all (deletes all vlans) Name VLAN ID List VLAN ID Type Table Integer N/A 1 4095 Values Access Parameter R RW vlantbl vlanid 139 Command Line Interface Configuration from the Base Station: Subscriber Station List Subscriber Station List Tsunami MP.16 3650 System User Guide All SSs in the Subscriber Station List are authorized to join the network. Depending on the Net Entry mode of the Base Station, this list is populated as follows:
Unrestricted mode: SSs are automatically added to the Subscriber Station List upon registering with the network. The default SS Class configured during SS Authentication is initially assigned to SSs. Internal authorization mode: Each SS must be manually added to the Subscriber Station List. An SS class is assigned manually during this process. CAUTION: In internal authorization mode, only SSs in the Subscriber Station List are authorized to join the network. External authorization mode: SSs are added to the Subscriber Station List automatically by the configured RADIUS server. The RADIUS server assigns an SS class. CAUTION: When changing to external authorization from any other authorization type, SSs currently in the SS List must be manually deleted. The administrator may optionally configure parameters of individual SSs on the list, including assigning an SS class, overriding particular elements of an assigned SS Class, and resetting overridden parameters to their default states. To view the entries in the SS List, enter the following command at the root prompt:
MP16>show ss To add an SS MAC address to the SS List, use the add command as follows, at the root prompt:
MP16>add ss <SS MAC address>
To assign an SS Class, enter the following:
MP16>configure ss <SS MAC address>
MP16(SS MAC Address)>set ssclass <SS Class Name>
Additionally, you can configure parameters specific to the particular Subscriber Station from the ss configuration prompt. These values will override the values of the associated SS Class. For example, assume Subscriber Station 1 (SS1) is set to use SS Class 1 (SSCLASS1), and that SSCLASS1 has a VLAN mode of Trunk. If you want SS1 to use SSCLASS1, but to use a VLAN mode of Access, you could override the VLAN mode of the class by configuring the VLAN mode for SS1 only in the SS table. If you do not configure any parameters specific to the SS, the SS Class parameters will be applied. You may also reset the overrides to the original Class parameters. To view all configurable parameters for the SS, enter the following command at the SS prompt:
MP16(SS MAC Address)>set ?
To view all configured parameters for the SS, enter the following command at the SS prompt:
MP16(SS MAC Address)>show The following parameters can be configured for the SS:
Name MAC Address SS Class Type Values Access Parameter MAC Address DisplayString Alphanumeric R RW macaddr ssclass 140 Command Line Interface Configuration from the Base Station: Subscriber Station List Tsunami MP.16 3650 System User Guide Name Type Uplink Modulation Type Integer Downlink Modulation Type Integer VLAN Mode Integer Values adaptive bpsk_1_2 qpsk_1_2 qpsk_3_4 qam16_1_2 qam16_3_4 qam64_2_3 qam64_3_4 adaptive bpsk_1_2 qpsk_1_2 qpsk_3_4 qam16_1_2 qam16_3_4 qam64_2_3 qam64_3_4 transparent (default) access trunk mixed inherited*
1 4095 0 7 Integer Integer VLAN ID (used in Access Mode or Trunk mode)
(see Access Mode and Trunk Mode) Management Priority
(used in Access mode)
(see Access Mode) Access ID (used in Mixed mode) (See Mixed Mode) Access Priority ((used in Mixed mode) (See Mixed Mode) Trunk ID (used in Mixed mode) (See Mixed Mode)
* Use inherited to use the VLAN parameters associated with the assigned SS Class. 1 4095 1 4095 Integer Integer Integer 0 7 Access Parameter RW upmodtype RW downmodtype RW vlanmode RW RW RW RW RW vlanid priority accessid accesspriority trunkid Transparent Mode To set the VLAN mode for the SS to Transparent:
MP16(SS MAC Address)>set vlanmode transparent Access Mode To configure the SS for Access mode, set the mode the Access, specify an allowed VLAN ID, and set the management priority. The VLAN ID will also be the management ID. MP16(SS MAC Address)>set vlanmode access vlanid <1 -4095> priority <0 - 7>
MP16(SS MAC Address)>add vlanid <1 - 4095>
141 Command Line Interface Configuration from the Base Station: Subscriber Station List Tsunami MP.16 3650 System User Guide Trunk Mode To configure the SS for Trunk mode, set the mode the Trunk and specify a VLAN management ID. Then use the add and delete commands to configure a group of allowed VLAN IDs. This group may contain up to 16 VLAN IDs. MP16(SS MAC Address)>set vlanmode trunk vlanid <Management VLAN ID>
MP16(SS MAC Address)>add vlanid <1 - 4095>
. MP16(SS MAC Address)>add vlanid <1 - 4095>
Mixed Mode To configure the SS for Mixed mode, set the mode the Mixed and specify a VLAN Access ID and a VLAN Trunk ID to be used for management, as well as an Access priority. Then use the add and delete commands to configure a group of allowed VLAN IDs. This group may contain up to 16 VLAN IDs.
<Management VLAN ID> access priority <0-7>
MP16(SS MAC Address)>set vlanmode mixed accessid <Management VLAN ID> trunkid MP16(SS MAC Address)>add vlanid <1 - 4095>
. MP16(SS MAC Address)>add vlanid <1 - 4095>
142 Command Line Interface Configuration from the Base Station: Service Class Creation Service Class Creation Tsunami MP.16 3650 System User Guide Service classes, also called Subscriber Station Classes (SS Classes), are comprised of uplink and downlink Service Flows, each of which has specific QoS settings. Traffic is directed to Service Flows through the application of Packet Identification Rules. See Wireless Communication and Service Classes for a brief overview of SS Classes and Service Class Creation for a more detailed discussion of SS Class creation. The MP.16 system comes supplied with pre-defined SS Classes, Service Flows, and PIRs. In addition, you can customize the predefined SS Classes, Service Flows, and PIRs, or create new ones that uniquely serve the needs of your network environment. While SS Classes use Service Flows and PIRs to direct traffic, each of these can be configured independently. That is, if you want to create a new SS Class that uses a new PIR or Service Flow, you must first define the new PIR or Service Flow, and then define the new SS Class that uses them. Alternatively, you may create a new SS Class that uses pre-defined PIRs and Service Flows, or you create a new PIR or Service flow to be used with a pre-defined SS class. Each element of the class is defined separately from the others. See the following sections for instructions:
Subscriber Station Classes: Create and configure new Subscriber Station classes; edit pre-defined SS Classes. Service Flows: Create and configure new service flows; edit pre-defined Service Flows. Packet Identification Rules: Create and configure new PIRs; edit pre-defined PIRs. Subscriber Station Classes You may create, modify, and delete up to 64 SS Classes, including those that are pre-defined. If the Base Station is reset to factory defaults, the original values of the parameters for the pre-defined Subscriber Station classes are restored. To create an new SS Class, enter the following command at the root prompt:
MP16 >add ssclass <name of SS class>
To view a list of all SS classes, enter the following from the root prompt:
MP16>show ssclass To view the configuration of an SS Class, enter the following from the root prompt:
MP16>show ssclass <SS Class Name>
To delete an SS Class, enter the following from the root prompt:
MP16>delete ssclass <SS Class Name>
To configure the parameters of a particular Subscriber Station class, you must access the ssclass configuration prompt. Enter the following at the root prompt:
MP16>configure ssclass <name of SS class>
The prompt will change to:
MP16(SS Class name)>
To view the configuration of the current SS Class, enter the following from the ssclass configuration prompt:
MP16>show From the ssclass configuration prompt, you can add, set, and show parameters as described in the following sections:
Adding Service Flows to an SS Class Associating PIRs with Added Service Flows Configuring SS Class VLAN Parameters See SS Class Creation Example for a step-by-step configuration example. 143 Command Line Interface Configuration from the Base Station: Service Class Creation Tsunami MP.16 3650 System User Guide Subscriber Station Class Parameters Name VLAN Mode Type Integer Values transparent (default) access trunk mixed 1 4095 VLAN ID (used in Access Mode or Trunk mode)
(see Access Mode and Trunk Mode) Management Priority
(used in Access mode)
(see Access Mode) Access ID (used in Mixed mode) (See Mixed Mode) Access Priority ((used in Mixed mode) (See Mixed Mode) Trunk ID (used in Mixed mode) (See Mixed Mode) Integer Integer 0 7 Integer 1 4095 Integer 0 7 Integer 1 4095 Access Parameter RW vlanmode RW RW RW RW RW vlanid priority accessid accesspriority trunkid Adding Service Flows to an SS Class You can add up to 16 Service Flows to the Subscriber Station Class. To add a service flow for a Subscriber Station class:
MP16(SS Class name)>add sfclass <service flow class name> <type>
where <type> is one of the following:
IPv4 ENET: Use this type when associated PIRs use at least one IP classifier and no VLAN classifiers. Ethernet classifiers are optional. IPv4 VLAN: Use this type when associated PIRs use at least one IP classifier and one VLAN classifier. ENET 802.3: Use this type when associated PIRs use only Ethernet classifiers. VLAN 802.1Q: Use this type when associated PIRs use only VLAN classifiers. NOTE: If the Service Flow has not yet been defined, or if the Service Flow is already added to the SS class, an error message will be displayed. Associating PIRs with Added Service Flows For each service flow, you can associate up to 16 PIRs. To add a PIR to a Service Flow within the context of a particular Subscriber Station class:
MP16(SS Class name)>add pir <SF Class name> <PIR name> <priority>
where <priority> is a value between 1 and 255. NOTE: If the PIR has not yet been defined, or if the Service Flow already has the maximum number of PIRs added to it, an error message will be displayed. 144 Command Line Interface Configuration from the Base Station: Service Class Creation Tsunami MP.16 3650 System User Guide Configuring SS Class VLAN Parameters For each SS Class, you can set the VLAN mode and, depending the mode, associated VLAN parameters. See the following:
Configuring the SS Class for Transparent Mode Configuring the SS Class for Access Mode Configuring the SS Class for Trunk Mode Configuring the SS Class for Mixed Mode Configuring the SS Class for Transparent Mode If the BS VLAN mode is set to Transparent, you can set the VLAN mode of the SS Class to either Transparent or Access. To set the VLAN mode to Transparent, enter the following:
MP16(SS Class name)>set vlanmode transparent With the VLAN mode set to Transparent, no further VLAN parameters need to be set. Configuring the SS Class for Access Mode If the BS VLAN mode is set to Transparent, you can set the VLAN mode of the SS Class to either Transparent (see above) or Access. If you set the VLAN mode to Access, an allowed VLAN ID, and set the management priority. The VLAN ID will also be the management ID. The VLAN ID must be taken from the VLAN ID List. MP16(SS Class Name)> set vlanmode access vlanid <value> priority <value>
Configuring the SS Class for Trunk Mode If the BS VLAN mode is set to Trunk, you can set the VLAN mode of the SS Class to either Access (see above), Trunk
(described here) or Mixed (see below). When setting the VLAN mode to Trunk, you must also specify a VLAN ID that will have management access. This VLAN ID must be one of the VLAN IDs configured in the VLAN ID List. MP16(SSCLASS1)>set vlanmode trunk vlanid <value>
With the VLAN mode to Trunk, you may add up to 16 entries to the list of allowed VLAN IDs. The allowed VLAN IDs must be from the VLAN ID List. MP16(SSCLASS1)>add vlanid <value>
. MP16(SSCLASS1)>add vlanid <value>
Configuring the SS Class for Mixed Mode If the BS VLAN mode is set to Trunk, you can set the VLAN mode of the SS Class to either Access (see above), Trunk
(see above) or Mixed (described here). When setting the VLAN mode to Access, you must also specify a VLAN Access ID and a VLAN Trunk ID to be used for management, as well as an Access priority. These VLAN IDs must be from the list of VLAN IDs configured in the VLAN ID List. MP16(SS MAC Address)>set vlanmode mixed accessid <Management VLAN ID> trunkid
<Management VLAN ID> access priority <0-7>
With the VLAN mode to Mixed, you may add up to 16 entries to the list of allowed VLAN IDs. The allowed VLAN IDs must be from the VLAN ID List. MP16(SSCLASS1)>add vlanid <value>
. 145 Command Line Interface Configuration from the Base Station: Service Class Creation MP16(SSCLASS1)>add vlanid <value>
Tsunami MP.16 3650 System User Guide SS Class Creation Example The following example assumes that you are creating a new SS Class using pre-defined Service Flows and PIRs. Step 1: Add New SS Class In this step, you are creating a new SS Class, called SSCLASS1, and entering the configuration prompt for that new Class. MP16>add ssclass SSCLASS1 MP16>configure SSCLASS1 MP16(SSCLASS1)>
From the configure prompt for the new SS Class, you can add Service Flows to the class. Step 2: Add Service Flows In this step, you are two uplink and two downlink Service Flows with associated Service Flow types. MP16(SSCLASS1)>add sfclass UL-SFCLASS1 ipv4_enet MP16(SSCLASS1)>add sfclass UL-SFCLASS2 vlan_802_1q MP16(SSCLASS1)>add sfclass DL-SFCLASS1 ipv4_enet MP16(SSCLASS1)>add sfclass DL-SFCLASS2 vlan_802_1q NOTE: If the Service Flow has not yet been defined, or if the Service Flow is already added to the SS class, an error message will be displayed. NOTE: To see a list of available SFs, return to the root prompt by pressing CTRL-Z, and enter show sfclass. Step 3: Associate PIRs with Service Flows In this step, you must associate PIRs with the added Service Flows. MP16(SSCLASS1)>add pir UL-SFCLASS1 PIR1 1 Above, you added PIR1 to UL-SFCLASS1 with a priority of 1. Now you will add more PIRs to Service Flows. MP16(SSCLASS1)>add pir UL-SFCLASS1 PIR3 2 MP16(SSCLASS1)>add pir UL-SFCLASS1 PIR7 5 MP16(SSCLASS1)>add pir UL-SFCLASS2 PIR16 9 MP16(SSCLASS1)>add pir DL-SFCLASS1 PIR6 3 MP16(SSCLASS1)>add pir DL-SFCLASS1 PIR4 1 NOTE: If the PIR has not yet been defined, or if the Service Flow already has the maximum number of PIRs added to it, an error message will be displayed. NOTE: To see a list of available PIRs, return to the root prompt by pressing CTRL-Z, and enter show pir. You have now added PIRs to Service Flows as follows:
UL-SFCLASS1 has three PIRs associated with it: PIR1, PIR3, and PIR7 UL-SFCLASS2 has one PIR, PIR16, associated with it. DL-SFCLASS1 has one PIR, PIR6, associated with it. DL-SFCLASS2 has one PIR, PIR4, associated with it Step 4: Configure SS Class VLAN Parameters Option A: Configuring SS Class for Transparent Mode If the BS VLAN mode is set to Transparent, you can set the VLAN mode of the SS Class to Transparent if you do not want to restrict access to the network. 146 Command Line Interface Configuration from the Base Station: Service Class Creation MP16(SSCLASS1)>set vlanmode transparent No further parameters need to be set. Tsunami MP.16 3650 System User Guide Option B: Configuring SS Class for Access Mode If the BS VLAN mode is set to Transparent, you can set the VLAN mode of the SS Class to Access to restrict access to the network. When you select Access, you must also select a VLAN ID with management access and set the management priority. The Management VLAN ID must be taken from the VLAN ID List configured from the root prompt or from the Configuration > Networking > VLAN ID List page in the Web interface. MP16(SSCLASS1)>set vlanmode access vlanid 25 priority 1 Above, you selected VLAN ID 25 as the Management VLAN ID for the SS Class, and you set the Management Priority to 1. Option C: Configuring SS Class for Trunk Mode If the BS VLAN mode is set to Trunk, you can set the VLAN mode of the SS Class Trunk to allow access by multiple VLANs. When you select Trunk, you must also select a VLAN ID for management access. MP16(SSCLASS1)>set vlanmode trunk vlanid 1 With the VLAN mode to Trunk, you can add up to 16 entries to the list of allowed VLAN IDs. The VLAN IDs must be taken from the VLAN ID List configured from the root prompt or from the Configuration > Networking > VLAN ID List page in the Web UI. MP16(SSCLASS1)>add vlanid 15 MP16(SSCLASS1)>add vlanid 25 MP16(SSCLASS1)>add vlanid 100 Above, you selected VLAN ID 1 as the Management VLAN ID, and added VLAN IDs 15, 25, and 100 to the list of allowed VLAN IDs. Option D: Configuring SS Class for Mixed Mode If the BS VLAN mode is set to Trunk, you can set the VLAN mode of the SS Class to Mixed to allow both tagged and untagged frames to access the network. When you select Mixed mode, you must also specify a VLAN Access ID and a VLAN Trunk ID to be used for management, as well as an Access priority. MP16(SSCLASS1)>set vlanmode access accessid 1 access priority 7 trunkid 12 With the VLAN mode to Mixed, you can add up to 16 entries to the list of allowed VLAN IDs. The VLAN IDs must be taken from the VLAN ID List configured from the root prompt or from the Configuration > Networking > VLAN ID List page in the Web UI. MP16(SSCLASS1)>add vlanid 15 MP16(SSCLASS1)>add vlanid 25 MP16(SSCLASS1)>add vlanid 100 Above, you selected VLAN ID 1 as the Access Management VLAN ID and VLAN ID 12 as the Trunk Management VLAN ID. You then added VLAN IDs 15, 25, and 100 to the list of allowed VLAN IDs. Step 5: View SS Class Configuration In this step, you will review the SS Class configuration you just completed:
MP16(SSCLASS1)>show 147 Command Line Interface Configuration from the Base Station: Service Class Creation Tsunami MP.16 3650 System User Guide Service Flows You can create, modify, and delete up to 256 Service Flow classes, including those that are pre-defined on the Base Station. If the Base Station is reset to factory defaults, the original values of the parameters for the pre-defined service flow classes are restored. To create an new SF Class, enter the following command at the root prompt:
MP16 >add sfclass <SF Class name>
To view a list of all SF Classes, enter the following from the root prompt:
MP16>show sfclass To view the configuration of an SF Class, enter the following from the root prompt:
MP16>show sfclass <SF Class name>
To delete an SF, enter the following from the root prompt:
MP16>delete sfclass <SF Class name>
To configure the parameters of a particular SF Class, you must access the sfclass configuration prompt. Enter the following at the root prompt:
MP16>configure sfclass <SF Class name>
The prompt will change to:
MP16(SF Class name)>
To view the configuration of the current SF Class, enter the following from the sfclass configuration prompt:
MP16>show From the sfclass prompt, you can show or set parameters described below. Service Flow Class Parameters Name Type Values Access Parameter Service Flow Class ID Scheduling Type (see QoS Scheduling Types) Service Flow Direction Maximum Sustained Data Rate Minimum Reserved Traffic Rate Maximum Latency Tolerable Jitter Traffic Priority Integer NA Integer DisplayString32 ugs rtps nrtps (default) be uplink downlink 8 8192 kbps (in steps of 8 kbps) 8 8192 kbps in steps of 8 kbps
(default = 0) 5 100 ms (in steps of 5 ms) 5 100 ms (in steps of 5 ms) 0 7 Integer Integer Integer Integer Integer R RW RW RW RW RW RW RW sfclassid schedtype direction maxsusdatrt minresdatrt maxslat toljtr trafpriority QoS Scheduling Types Four QoS scheduling types are available. After selecting a scheduling type, set the associated parameters, as follows:
UGS: The following QoS parameters are configurable (see table above):
Maximum sustained information rate 148 Command Line Interface Configuration from the Base Station: Service Class Creation Tsunami MP.16 3650 System User Guide Maximum latency Tolerable jitter rtPS: The following QoS parameters are configurable (see table above):
Maximum sustained information rate Minimum reserved traffic rate Maximum latency nrtPS: The following QoS parameters are configurable (see table above):
Maximum sustained information rate (MIR) Minimum reserved traffic rate Traffic priority BE: The following QoS parameters are configurable (see table above):
Maximum sustained information rate (MIR) Traffic priority Packet Identification Rules You can create, modify, and delete up to 512 Packet Identification Rules (PIRs), including those that are pre-defined on the Base Station. If the Base Station is reset to factory defaults, the original values of the parameters for the pre-defined PIRs are restored. To create an new PIR, enter the following command at the root prompt:
MP16 >add pir <PIR name>
To view a list of all PIRs, enter the following from the root prompt:
MP16>show pir To view the configuration of a PIR, enter the following from the root prompt:
MP16>show pir <PIR name>
To delete a PIR, enter the following from the root prompt:
MP16>delete PIR <PIR name>
To configure the parameters of a particular PIR, you must access the pir configuration prompt. Enter the following at the root prompt:
MP16>configure pir <PIR name>
The prompt will change to:
MP16(PIR name)>
To view the configuration of the current PIR, enter the following from the pir configuration prompt:
MP16>show From the pir prompt, use the add command to configure parameters as described in the following sections. PIR Parameters NOTE: PIR parameters are configured using the add command. Name Blocked Type Integer Values enable disable (default) See Blocked (blocked) Access RW blocked Parameter 149 Command Line Interface Configuration from the Base Station: Service Class Creation Tsunami MP.16 3650 System User Guide Name IP Type of Service IP Protocol List IP Source & Mask List Ethernet Source MAC and Mask Type Integer Table Table Table Protocol Source Port Range Table IP Destination & Mask List Table Ethernet Destination MAC and Mask Table Protocol Destination Port Range Ethernet Type/Value Ethernet Priority VLAN ID Table Table Integer Integer Values Access Parameter See IP Type of Service
(iptos) See IP Protocol List
(ipproto) See IP Source Address and Mask List (scrcipaddr) See Ethernet Source MAC Address and Mask
(srcmacaddr) See Protocol Source Port Range (srcport) See IP Destination Address and Mask List
(destippaddr) See Ethernet Destination MAC Address and Mask
(destmacaddr) See Protocol Destination Port Range (destport) See Ethernet Type/Value
(ethertype) See Ethernet Priority
(ethernetpriority) See VLAN ID (vlanid) RW RW RW RW RW RW RW RW RW RW RW iptos ipproto srcipaddr srcmacaddr srcport destipaddr destmacaddr destport ethertype ethernetpriority vlanid Blocked (blocked) When the blocked parameter is enabled, packets matching the classifiers configured below are blocked. When disabled, packets matching the classifiers configured below are allowed. Use the following syntax:
MP16(PIR Name)>add blocked <enable/disable>
IP Type of Service (iptos) The IP Type of Service parameters are under the group iptos. To add IP Type of Service entries, use the following syntax:
MP16(PIR Name)>add iptos <iptos low value> <iptos high value> <iptos mask value>
where all values are between 0 and 255. Execute a show command to view the value of the IPTOS parameters:
MP16(PIR Name)>show iptos To delete iptos entries:
MP16(PIR Name)>delete iptos IP Protocol List (ipproto) The IP Protocol list is grouped under ipproto. Up to 16 entries can be added to this list. To add entries:
MP16(PIR Name)>add ipproto <value>
where <value> is a number between 1 255. 150 Command Line Interface Configuration from the Base Station: Service Class Creation Tsunami MP.16 3650 System User Guide Execute a show command to view the entries in the IP Protocol List:
MP16(PIR Name)>show ipproto To delete a single IP Protocol List entry:
MP16(PIR Name)>delete ipproto <index>
To delete all entries:
MP16(PIR Name)>delete ipproto all IP Source Address and Mask List (scrcipaddr) The IP source address and mask parameters are under the group srcipaddr. Up to 16 entries can be added to this list. To add entries, use the following syntax:
MP16(PIR Name)>add scripaddr <source IP address> <mask>
Execute a show command to view the entries in the IP Source Address and Mask List, with index numbers:
MP16(PIR Name)>show srcipaddr To delete an entry in the table:
MP16(PIR Name)>delete srcipaddr <index>
To delete all entries in the table Ethernet Source MAC Address and Mask (srcmacaddr) The Ethernet source MAC address and mask parameters are under the group srcmacaddr. To add an entry:
MP16(PIR Name)>add srcmacaddr <Ethernet destination MAC address> <mask>
Execute a show command to view Ethernet Source MAC and Mask parameters, with index numbers:
MP16(PIR Name)>show srcmacaddr To delete an entry in the table:
MP16(PIR Name)>delete srcmacaddr <index>
To delete all entries in the table MP16(PIR Name)>delete srcmacaddr all Protocol Source Port Range (srcport) This range may only be configured if TCP and/or UDP are included in the IP Protocol list. The IP protocol source port start and end parameters are under the group srcport. Up to 16 entries can be added to this list. To add entries, use the following syntax:
MP16(PIR Name)>add srcport <start port value> <end port value>
where:
<start port value> is the low-end inclusive range of TCP/UDP source port numbers to which a packet is compared and
<end port value> is the high-end inclusive range of TCP/UDP source port numbers to which a packet is compared. The range is between 0 65535. Execute a show command to view the entries in the Protocol Source Port range, with index numbers:
MP16(PIR Name)>show srcport To delete an entry in the table:
MP16(PIR Name)>delete srcport <index>
151 Command Line Interface Configuration from the Base Station: Service Class Creation Tsunami MP.16 3650 System User Guide To delete all entries in the table:
MP16(PIR Name)>delete srcport all MP16(PIR Name)>delete srcipaddr all IP Destination Address and Mask List (destippaddr) The IP source address and mask parameters are under the group destipaddr. Up to 16 entries can be added to this list. To add entries, use the following syntax:
MP16(PIR Name)>add destipaddr <destination IP address> <mask>
Execute a show command to view the entries in the IP Destination Address and Mask List, with index numbers:
MP16(PIR Name)>show destipaddr To delete an entry in the table:
MP16(PIR Name)>delete destipaddr <index>
To delete all entries in the table MP16(PIR Name)>delete destipaddr all Ethernet Destination MAC Address and Mask (destmacaddr) The Ethernet source MAC address and mask parameters are under the group srcmacaddr. To add an entry:
MP16(PIR name)> add destmacaddr <Ethernet source MAC address> <mask>
Execute a show command to view Ethernet Destination MAC and Mask parameters, with index numbers:
MP16(PIR Name)>show destmacaddr To delete an entry in the table:
MP16(PIR Name)>delete destmacaddr <index>
To delete all entries in the table MP16(PIR Name)>delete destmacaddr all Protocol Destination Port Range (destport) This range may only be configured if TCP and/or UDP are included in the IP Protocol list. The IP protocol source port start and end parameters are under the group destport. Administrators can add up to 16 entries in this list. To add an entry, use the following syntax:
MP16(PIR Name)>add destport <start port value> <end port value>
where <start port value> is the low-end inclusive range of TCP/UDP source port numbers to which a packet is compared, and <end port value> is the high-end inclusive range of TCP/UDP source port numbers to which a packet is compared. The range is between 0 65535. Execute a show command to view the entries in the Protocol Destination Port range, with index numbers:
MP16(PIR Name)>show destport To delete an entry in the table:
MP16(PIR Name)>delete destport <index>
To delete all entries in the table MP16(PIR Name)>delete destport all 152 Command Line Interface Configuration from the Base Station: Logging Configuration Tsunami MP.16 3650 System User Guide Ethernet Type/Value (ethertype) The Ethernet Type parameter designates the Ethernet type on which the filtering is to be done. To add an Ethernet type entry:
MP16(PIR Name)>add ethertype <value> <Ethernet Protocol Type>
where <value> is dix_snap or dsap, and <Ethernet Protocol Type> is a 16-bit value if dix_snap is selected, and an 8-bit value if dsap is selected. Ethernet protocol type can be one of the following:
0200 (Xerox PUP) 6001 (DEZ MOP) 8005 (HP Probe) 809B (AppleTalk) Execute a show command to view Ethernet type:
MP16(PIR Name)>show ethertype To delete the Ethernet type:
MP16(PIR Name)>delete ethertype Ethernet Priority (ethernetpriority) The Ethernet priority parameters are under the group ethernetpriority. To add an entry:
MP16(PIR Name)>add ethernetpriority <Ethernet priority low> <Ethernet priority high>
where <ethernet priority low> and <ethernet priority high> are values in the range 0 - 7. Execute a show command to view Ethernet priority:
MP16(PIR Name)>show ethernetpriority To delete the Ethernet priority:
MP16(PIR Name)>delete ethernetpriority VLAN ID (vlanid) The VLAN ID designates the VLAN on which the filtering is to be done. To add a VLAN ID:
MP16(PIR Name)>add vlanid <value>
where <value> is a number between 0 4095 (0 = unused). To delete the VLAN ID:
MP16(PIR Name)>delete vlandid Logging Configuration To configure logging related parameters, enter the following command at the root prompt:
MP16>configure log The prompt will change to:
MP16(log)>
From the log configuration prompt, you can set or show the following logging configuration parameters:
153 Command Line Interface Configuration from the Base Station: Trap Host Parameters Tsunami MP.16 3650 System User Guide Type Values Parameter Name Volatile Log Status Non-Volatile Log Status Volatile Log Filter Level Integer Integer Integer Non-Volatile Log Filter Level Integer vlogstatus nvlogstatus vloglevel nvloglevel enable disable enable disable none emergency alert critical error warning notice informational debug all none emergency alert critical error warning notice informational debug all Trap Host Parameters To configure the Trap Host parameters, you must first add a Trap Host. Enter the following command from the root prompt:
MP16>add traphost <IP Address>
To configure the added Trap Host, enter the following command from the root prompt:
MP16>configure traphost <IP Address>
The prompt will change to:
MP16(trap host IP Address)>
Name IP Address Password Status Comment Type IP Address DisplayString Integer DisplayString Values Access Parameter User defined User defined enable disable (default) User defined RW W RW RW password status comment Management Interface Parameters To configure the management interface parameters, enter the following command from the root prompt:
MP16> configure mgmtinterface The prompt will change to:
MP16(configure-mgmtinterface)>
154 Command Line Interface Configuration from the Base Station: Management Interface Parameters Tsunami MP.16 3650 System User Guide Name Type SNMP Enable/Disable Integer Values enable (default) disable Access Parameter RW snmp 155 Command Line Interface Configuration from the Subscriber Station: Subscriber Station Device Configuration Configuration from the Subscriber Station Tsunami MP.16 3650 System User Guide Log into the Subscriber Station and use the configure, delete, set, and show commands to set or view local SS parameters. See the following sections:
Subscriber Station Device Configuration Radio Configuration Logging Configuration Subscriber Station Device Configuration To configure the individual SS parameters, enter the following command from the root prompt:
MP16>configure ss The prompt will change to:
MP16(ss)>
From the ss prompt, you can show or set parameters in the following groups:
Device Parameters IP Addresses/Masks Device Parameters Name Name Location Contact Name Contact Email Type DisplayString DisplayString DisplayString DisplayString Contact Phone Number DisplayString Values Access Parameter 1 255 alphanumeric characters 1 255 alphanumeric characters 1 255 Alphanumeric characters 1 255 alphanumeric characters 1 255 alphanumeric characters RW RW RW RW RW sysname location contact emailid phone IP Addresses/Masks Name IP Address Default Gateway Type IP Address IP Address Values Valid IP address Access Parameter RW RW ipaddr dfltgw To set the IP Address and Mask:
MP16(ss)>set ipaddr <interface> <ipaddress> <mask>
where <interface> is Ethernet (enet0). To set the Default Gateway:
MP16(ss)>set dfltgw <ipaddress>
Radio Configuration To configure the radio parameters for an SS, enter the following command from the root prompt:
156 Command Line Interface Configuration from the Subscriber Station: Logging Configuration Tsunami MP.16 3650 System User Guide MP16>configure radio The prompt will change to:
MP16(radio)>
From the radio prompt, you can show or set the following parameters:
Name Base Station ID Center Frequency Channel Bandwidth Logging Configuration Type Values MacAddress Valid MAC address 3650000 - 3675000 Integer
(in steps of 250) Default: 3685000 3.5 7 auto (default) Integer Access Parameter RW RW RW bsid centerfreq chbandwidth To configure logging related parameters, enter the following command at the root prompt:
MP16>configure log The prompt will change to:
MP16(log)>
From the log configuration prompt, you can set or show the following logging configuration parameters:
Values Parameter loglevel Name Logging Filter Level Type Integer Logging Filter Module IDs DisplayString none emergency alert critical error warning notice informational debug dhcp tftp mac bridge snmp netentry pa Logging Output Interfacebitmask 00000000 (0x00): No logging 00000001 (0x01): RAM 00000010 (0x02): NVRAM 00000111 (0x04): Logging in RAM, NVRAM To view all logs of a specified level for a particular module:
MP16(log)>show logmodid <value>
To view all logs for a particular module:
logmodid logop 157 Command Line Interface Configuration from the Subscriber Station: Logging Configuration MP16(log)>show logmodid <value>
To view a list of logs:
MP16(log)>show Tsunami MP.16 3650 System User Guide 158 Tsunami MP.16 3650 System User Guide Command Line Interface Monitoring the BS and SS: Software Version Monitoring the BS and SS Software Version Network Status (SS only) Software Version Base Station Statistics Subscriber Station Statistics Software Version You can view the version number of the application image and the firmware version number on both the BS and the SS. Log into the BS or SS and enter the following command:
MP16>show version Network Status (SS only) You can view the network status of the SS. Log into the BS or SS and enter the following command:
MP16>show status Log Messages A message log is available on both the BS and SS. Common Log Messages The following log messages shall be supported on both the Subscriber Station and the Base Station:
Log Message Invalid HTTP Login Invalid SNMP Community Invalid CLI Login Base Station Log Messages The following log messages shall be supported in the Base Station:
Log Message Subscriber station xx:xx:xx:xx:xx:xx successfully entered the network Subscriber station xx:xx:xx:xx:xx:xx authorization failure Subscriber station xx:xx:xx:xx:xx:xx exited the network Subscriber station xx:xx:xx:xx:xx:xx adapted uplink/downlink from y to z. (e.g., y,z = BPSK-1/2) No response from Radius Server Service Flow xxxx successfully activated Subscriber station xx:xx:xx:xx:xx:xx power adjusted by # dB Subscriber Station Log Messages The following log messages shall be supported at the Subscriber Station:
Subscriber station adjusted power by # dB Log Message Severity Warning Warning Warning Severity Informational Warning Informational Informational Alert Informational Informational Severity Informational 159 Command Line Interface Monitoring the BS and SS: Log Messages Tsunami MP.16 3650 System User Guide Service Flow xxxx successfully activated Subscriber station lost link to BSID xx:xx:xx:xx:xx:xx Subscriber station successfully connected to BSID xx:xx:xx:xx:xx:xx Subscriber station requesting downlink adaptation from y to z Informational Alert Informational Informational 160 Tsunami MP.16 3650 System User Guide Command Line Interface Monitoring the BS and SS: Base Station Statistics Base Station Statistics BS MAC Statistics To view BS MAC statistics, enter the following command:
MP16>show macstats The following statistics will be displayed:
Number of packets transmitted Number of packets received Number of CRC errors Number of bad HCSs Current temperature BS Ethernet Statistics To view BS Ethernet statistics, enter the following command:
MP16>show pkstats The following statistics will be displayed:
Number of unicast packets transmitted Number of unicast packets received Number of multicast packets transmitted Number of multicast packets received Number of broadcast packets transmitted Number of broadcast packets received BS GPS Statistics To view BS GPS statistics, enter the following command:
MP16>show gpsstats This command will display the GPS Sync status Per-SS Statistics To view statistics for registered Subscriber Stations, enter the following command:
MP16>show stnlist (displays information for each SS) MP16>show stnlist <SS MAC Address> (displays information for a particular SS) The following information will be displayed:
Basic CID Primary CID Uplink modulation Downlink modulation Uplink PER TX power Elapsed time since network entry 161 Command Line Interface Monitoring the BS and SS: Base Station Statistics Tsunami MP.16 3650 System User Guide Maximum RSL Maximum RX Gain Uplink packets Downlink packets Per-Service Flow Statistics To view Service Flow statistics, enter the following command:
MP16>show sfstats (displays information for all Service Flows) MP16>show sfstats <Service Flow ID> (displays information for a particular Service Flow) The following information will be displayed:
Service Flow ID Service Flow Class name State (provisioned, admitted, or active) Direction Packets sent (only when showing statistics for a particular SF) CID (if connected) GPS Statistics To view GPS statistics, enter the following command:
MP16>show gpsstats 162 Command Line Interface Monitoring the BS and SS: Subscriber Station Statistics Subscriber Station Statistics Log in to the Subscriber Station to view SS Statistics. SS Bridge Statistics To view SS bridge statistics, enter the following command:
MP16>show bridgestat The following statistics will be displayed:
Bridge port Number of frames received Number of frames sent Number of frames discarded SS MAC Statistics To view SS MAC statistics, enter the following command:
MP16>show macstats The following statistics will be displayed:
Total packets sent Total packets received Total HCS errors Total CRC errors Current temperature Average RSSI Average RSL Average SNR Current uplink modulation Current downlink modulation Elapsed time since entry SS Ethernet Statistics To view SS Ethernet statistics, enter the following command:
MP16>show pkstats The following statistics will be displayed:
Number of unicast packets transmitted Number of unicast packets received Number of multicast packets transmitted Number of multicast packets received Per-Service Flow Statistics To view Service Flow statistics, enter the following command:
Tsunami MP.16 3650 System User Guide 163 Command Line Interface Monitoring the BS and SS: Subscriber Station Statistics Tsunami MP.16 3650 System User Guide MP16>show sfstats (displays statistics for all Service Flows) MP16>show sfstats <Service Flow ID> (displays statistics for a particular Service Flow) The following information will be displayed:
Service Flow ID Service Flow Class name State (active, provisioned, admitted) Direction Packets sent (only when showing statistics for a particular SF) CID (if connected) Service Flow Statistics To view Service Flow information, enter the following command:
MP16>show sf (displays configuration information all Service Flows) MP16>show sf <Service Flow Name> (displays configuration information for a particular Service Flow) 164 Tsunami MP.16 3650 System User Guide C Technical Services and Support See the following sections:
Obtaining Technical Services and Support Support Options Proxim eService Web Site Support Telephone Support ServPak Support Obtaining Technical Services and Support If you are having trouble utilizing your Proxim product, please review this manual and the additional documentation provided with your product. If you require additional support and would like to use Proxims free Technical Service to help resolve your issue, please be ready to provide the following information before you contact Proxims Technical Services:
Product information:
Part number of suspected faulty unit Serial number of suspected faulty unit Trouble/error information:
Trouble/symptom being experienced Activities completed to confirm fault Network information (what kind of network are you using?) Circumstances that preceded or led up to the error Message or alarms viewed Steps taken to reproduce the problem Servpak information (if a Servpak customer):
Servpak account number Registration information:
If the product is not registered, date when you purchased the product If the product is not registered, location where you purchased the product NOTE: If you would like to register your product now, visit the Proxim eService Web Site at http://support.proxim.com and click on New Product Registration. 171 Technical Services and Support Support Options: Proxim eService Web Site Support Support Options Proxim eService Web Site Support Tsunami MP.16 3650 System User Guide The Proxim eService Web site is available 7x24 at http://support.proxim.com. On the Proxim eService Web Site, you can access the following services:
New Product Registration: Register your product for free support. Open a Ticket or RMA: Open a ticket or RMA and receive an immediate reply. Search Knowledgebase: Locate white papers, software upgrades, and technical information. ServPak (Service Packages): Receive Advanced Replacement, Extended Warranty, 7x24x365 Technical Support, Priority Queuing, and On-Site Support. Your Stuff: Track status of your tickets or RMAs and receive product update notifications. Provide Feedback: Submit suggestions or other types of feedback. Customer Survey: Submit an On-Line Customer Survey response. Repair Tune-Up: Have your existing Proxim equipment inspected, tested, and upgraded to current S/W and H/W revisions, and extend your warranty for another year. Telephone Support Contact technical support via telephone as follows:
US and Canada: 408-383-7700, 866-674-6626 (Toll Free) Hours of Operation: 8.00AM-6.00PM, Pacific Time, Monday-Friday APAC Countries: +91 40 23115490 Hours of Operation: 9.00AM-6.00PM, IST (UTC/GMT +5.30 Hrs.), Monday-Friday International: 408-383-7700 Hours of Operation: 8.00AM-6.00PM, Pacific Time, Monday-Friday ServPak Support Proxim understands that service and support requirements vary from customer to customer. It is our mission to offer service and support options that go above-and-beyond normal warranties to allow you the flexibility to provide the quality of service that your networks demand. In recognition of these varying requirements we have developed a support program called ServPak. ServPak is a program of Enhanced Service Options that can be purchased individually or in combinations to meet your needs. Advanced Replacement: This service offers customers an advance replacement of refurbished or new hardware.
(Available in the U.S., Canada, and select countries. Please inquire with your authorized Proxim distributor for availability in your country.) Extended Warranty: This service provides unlimited repair of your Proxim hardware for the life of the service contract. 7x24 Technical Support: This service provides unlimited, direct access to Proxims world-class technical support 24 hours a day, 7 days a week, 365 days a year. Priority Queuing: This service allows your product issue to be routed to the next available Customer Service Engineer. To purchase ServPak support services, please contact your authorized Proxim distributor. To receive more information or for questions on any of the available ServPak support options, please call Proxim Support at 408-383-7700 or send an email to servpak@proxim.com. 172 Statement of Warranty Warranty Coverage Tsunami MP.16 3650 System User Guide D Proxim Wireless Corporation warrants that its Products are manufactured solely from new parts, conform substantially to specifications, and will be free of defects in material and workmanship for a Warranty Period of 1 year from the date of purchase. Repair or Replacement In the event a Product fails to perform in accordance with its specification during the Warranty Period, Proxim offers return-to-factory repair or replacement, with a thirty (30) business-day turnaround from the date of receipt of the defective Product at a Proxim Wireless Corporation Repair Center. When Proxim Wireless Corporation has reasonably determined that a returned Product is defective and is still under Warranty, Proxim Wireless Corporation shall, at its option, either: (a) repair the defective Product; (b) replace the defective Product with a refurbished Product that is equivalent to the original; or (c) where repair or replacement cannot be accomplished, refund the price paid for the defective Product. The Warranty Period for repaired or replacement Products shall be ninety (90) days or the remainder of the original Warranty Period, whichever is longer. This constitutes Buyers sole and exclusive remedy and Proxim Wireless Corporations sole and exclusive liability under this Warranty. Limitations of Warranty The express warranties set forth in this Agreement will not apply to defects in a Product caused; (i) through no fault of Proxim Wireless Corporation during shipment to or from Buyer, (ii) by the use of software other than that provided with or installed in the Product, (iii) by the use or operation of the Product in an application or environment other than that intended or recommended by Proxim Wireless Corporation, (iv) by modifications, alterations, or repairs made to the Product by any party other than Proxim Wireless Corporation or Proxim Wireless Corporations authorized repair partners, (v) by the Product being subjected to unusual physical or electrical stress, or (vii) by failure of Buyer to comply with any of the return procedures specified in this Statement of Warranty. Support Procedures Buyer should return defective LAN Products1 within the first 30 days to the merchant from which the Products were purchased. Buyer can contact a Proxim Wireless Corporation Customer Service Center either by telephone or via web. Calls for support for Products that are near the end of their warranty period should be made not longer than seven (7) days after expiration of warranty. Repair of Products that are out of warranty will be subject to a repair fee. Contact information is shown below. Additional support information can be found at Proxims web site at http://support.proxim.com. US and Canada: 408-383-7700, 866-674-6626 (Toll Free) Hours of Operation: 8.00AM-6.00PM, Pacific Time, Monday-Friday APAC Countries: +91 40 23115490 Hours of Operation: 9.00AM-6.00PM, IST (UTC/GMT +5.30 Hrs.), Monday-Friday International: 408-383-7700 Hours of Operation: 8.00AM-6.00PM, Pacific Time, Monday-Friday When contacting the Customer Service for support, Buyer should be prepared to provide the Product description and serial number and a description of the problem. The serial number should be on the product. In the event the Customer Service Center determines that the problem can be corrected with a software update, Buyer might be instructed to download the update from Proxim Wireless Corporations web site or, if thats not possible, the update will be sent to Buyer. In the event the Customer Service Center instructs Buyer to return the Product to Proxim 173 Statement of Warranty Other Information: Search Knowledgebase Tsunami MP.16 3650 System User Guide Wireless Corporation for repair or replacement, the Customer Service Center will provide Buyer a Return Material Authorization (RMA) number and shipping instructions. Buyer must return the defective product to Proxim Wireless Corporation, properly packaged to prevent damage, shipping prepaid, with the RMA number prominently displayed on the outside of the container. Calls to the Customer Service Center for reasons other than Product failure will not be accepted unless Buyer has purchased a Proxim Wireless Corporation Service Contract or the call is made within the first thirty (30) days of the Products invoice date. A per-call fee will be charged for service beyond the 30-day free support time. Contact Proxim Support for detailed pricing. If Proxim Wireless Corporation reasonably determines that a returned Product is not defective or is not covered by the terms of this Warranty, Buyer shall be charged a service charge and return shipping charges. Other Information Search Knowledgebase Proxim Wireless Corporation stores all resolved problems in a solution database at the following URL:
http://support.proxim.com. Ask a Question or Open an Issue Submit a question or open an issue to Proxim Wireless Corporation technical support staff at the following URL:
http://support.proxim.com. Other Adapter Cards Proxim Wireless Corporation does not support internal mini-PCI devices that are built into laptop computers, even if identified as "ORiNOCO" devices. Customers having such devices should contact the laptop vendor's technical support for assistance. For support for a PCMCIA card carrying a brand name other than Proxim, ORiNOCO, Lucent, Wavelan, or Skyline, Customer should contact the brand vendor's technical support for assistance. 174
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2009-04-02 | 3654.25 ~ 3670.75 | TNB - Licensed Non-Broadcast Station Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2009-04-02
|
||||
1 | Applicant's complete, legal business name |
Proxim Wireless Corporation
|
||||
1 | FCC Registration Number (FRN) |
0005850607
|
||||
1 | Physical Address |
47633 Westinghouse Drive
|
||||
1 |
Fremont, California 94539
|
|||||
1 |
United States
|
|||||
app s | TCB Information | |||||
n/a | ||||||
app s | FCC ID | |||||
1 | Grantee Code |
HZB
|
||||
1 | Equipment Product Code |
MP163650S
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
C******** v******
|
||||
1 | Title |
Sr. Regulatory and Compliance Manager
|
||||
1 | Telephone Number |
408 3********
|
||||
1 | Fax Number |
408 3********
|
||||
1 |
c******@proxim.com
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
Proxim Wireless Corporation
|
||||
1 | Name |
V******** T******
|
||||
1 | Physical Address |
1561 Buckeye Dr
|
||||
1 |
Milpitas, California 95035
|
|||||
1 |
United States
|
|||||
1 | Telephone Number |
(408)********
|
||||
1 |
i******@proxim.com
|
|||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | TNB - Licensed Non-Broadcast Station Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Wireless Networking Device | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Output is EIRP. The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of 1.1307(b)(3). | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Micom Labs
|
||||
1 | Name |
G******** H******
|
||||
1 | Telephone Number |
925-4********
|
||||
1 | Fax Number |
925-4********
|
||||
1 |
g******@micomlabs.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 9 | RS | 3652.5 | 3670 | 3.5 | 20 ppm | 3M2W7D | |||||||||||||||||||||||||||||||||
1 | 2 | 9 | RS | 3654.25 | 3670.75 | 7 | 20 ppm | 6M4W7D |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC