WEA412h (Indoor type) Quick Installation Manual This manual describes the Wireless Enterprise WEA412h configuration and installation instructions. Introduction Side View What is WEA412h?
WEA412h is an Access Point (AP) which supports IEEE 802.11ac wave1 standards and it connects wireless devices such as smartphone, laptop, tablet and etc. to a wired network in a hospitality environment such as hotel, dormitory, and condominium. The WEA412h supports the following features.
- IEEE 802.11a/b/g/n/ac standards
- 2.4 GHz and 5 GHz concurrent radios.
- 2 2 Multiple Input Multiple Output (MIMO)
- Gigabit Ethernet 1 port (PoE In) for a WAN connection
- Gigabit Ethernet 4 ports (PoE Out 1 port) for an uplink connection for wired network
- Power over Ethernet (PoE) IEEE 802.3af/802.3at
- External 48 V/0.75 A power adaptor (Optional).
- PoE Output of 10 watts max with 802.3at mode or using 48 V/0.75 A power adaptor.
- A tricolored LED displaying the operational status of WEA412h.
- One USB port (Host 2.0) Components After unpacking the WEA412h, confirm that all of the following items have been included:
Torx Security Screw Hole Torx Security Screw Hole DC Input Kensington Security Slot USB Factory Reset Switch Interface Port Name Left Side Right Side Description Tricolored LED Displays the operational status of WEA412h using a tricolored LED. DC Input This is for connecting the power adapter. Ethernet Port (PoE In) Supports 1000 BASE-T Gigabit Ethernet and IEEE 802.3af/802.3at PoE mode. Ethernet Port
(LAN1~LAN4) USB Port Supports 1000 BASE-T Gigabit Ethernet and a PoE Output for the LAN1 port. Supports BLE and ZigBee dongle and provides the 2.5 W output power. Factory reset switch Used to reset the WEA412h to the initial factory settings. WEA412h LED status indicator Bracket for the standard junction box
(standard gang junction box) Four Phillips screws
(UNC #6-32, L8) Two Security Torx
(T10) screws Installation Manual Ordered separately Wall Mount Bracket Four plastic anchors Four Phillips screws (M4, L50)
- It is recommended to keep all packaging materials and the box.
- The power adaptor is sold separately. If necessary, contact the retailer. Names and Functions Front and Rear View LED Status Description System start status White On Initial LED status Blue On Red On Device reset and test in progress Booting failure (Device reset failure) Provisioning status Red, Green, and Off repeatedly APC connection in progress (Network link normal) Green blinking CAPWAP connection in progress (APC server connection normal) Normal operation status Upgrade Error status Green On Blue On Blue blinking Red blinking Yellow blinking Purple blinking When there is no connected wireless device When there is a connected wireless device Software upgrade in progress Physical connection error of network IP address conflict Dynamic IP address allocation failure Bluish-green blinking Logical connection error of network Off Wireless interface error Installation WEA412h can be installed on a general wall or on the standard junction box. Please confirm that all of the components have been included before installation. Before Installation Safety Requirements Ethernet Port (PoE In) Carefully observe the following safety warnings in order to avoid the risk of damage or injury. For safe use, make sure to be well-informed.
- There is a risk of electrical shock. Make sure that the power is turned off during installation. Do not proceed with the installation if there is any electrical current leaking. It may cause a serious electric shock.
- Wear anti-static gloves or take an appropriate action to prevent ESD when handling the product.
- Do not connect a phone line to an Ethernet port. This may damage the product.
- This product must be connected to a power supply in compliance with IEEE 802.3af/at or connected to a limited power supply in compliance with IEC60950.
- This product must be installed in a vertical direction. To prevent damage of a product and burns of a user due to heat caused when the product is installed in a horizontal direction, an operation of wireless LAN is compulsorily restricted when the surface temperature of the product exceeds IEC60950 standards (95C).
- This product must be installed or removed by only appropriately trained service personnel.
- This product operates in the Safety Extra Low Voltage (SELV) state in compliance with IEC60950.
- All the connected equipment including this product must be installed inside of the same building. For more details, refer to the Environment A of IEEE 802.3af/at standards.
- During installation, this product must be installed at least 3 m or more apart from WiBro/3G/4G repeater or antenna. Installation Instructions The following instructions must be carefully observed during installation.
- The system must be installed in a place that is easily accessible for product installation, cable connections, and maintenance. Bottom View
- The PoE cable must be always installed away from any electrical interference source such as power lines, fluorescent lights or transmitters.
- The PoE cable must be Cat 5e or higher.
- When PoE is unavailable, a power adapter (sold separately) can be used. The 3-pin (including ground) power socket that supplies 100~240 V AC, 50~60 Hz must be located within 2 m from each equipment and the power must be supplied through an independent circuit breaker. It is recommended to use the equipment that uses a filter or a surge. Ethernet Port
(PoE Out) Ethernet Port LED status indicator
- Whether a USB port and a PoE output port (LAN1/PoE Out) operate or not according to a power pull-in source is as follows. 1) Power adapter: an USB port (2.5 W) and a PoE output port (15.4 W) available 2) 802.3at: an USB port (2.5 W) and a PoE output port (10 W) available 3) 802.3af: both an USB port and a PoE output port are disabled Wall-mount installation on a junction box 1. Couple and assemble screws fitting to the type of the standard junction box. Location and number of screws to be coupled vary depending on the standard junction box.
: Standard gang junction box (Box for 1-Korea/USA)
: Standard gang junction box (Box for 2-Korea/USA)
: Standard gang junction box (Box for 1-EU) 2. Connect an Ethernet cable to the Ethernet (PoE In) port by passing through the standard junction box. 3. 1) Mount the AP on the bracket using two holes in 2) Push the AP backward and tightly connect the the lower end of the AP. AP to the bracket. 4. Fasten the AP to the bracket using Torx security screws (each one on the left/right sides). Connecting RJ11 phone cable coming from the standard junction box 1. Pull forward the RJ11 cable by passing through the rectangular hole on the bracket as shown in the picture. Standard junction box RJ45 Cable Connect to the Ethernet port
(PoE In) Bracket for the standard junction box RJ11 Cable Connect to the phone 2. Pass through the RJ11 cable into the cable groove located in the lower end of the product. Protrusion for preventing RJ11 cable leaves 3. 1) Fitting the left/right protrusion of the lower end of the bracket into the hole of the bottom of the AP. 2) Push the AP backward and tightly connect the AP with the bracket. RJ11 Cable Wall-mount installation directly on wall
(Wall mounting bracket, Anchors and Screws can be ordered separately) 1. Mark 4 screw holes along the following dimensions on a wall and drill them. (You can easily mark the screw holes by using a 1:1 sized drawing in the WEA412h Quick Installation Manual.) 62 mm 2. Hang the Ethernet cable on the wall mounting bracket as shown in the picture. 3. Mount the standard junction box bracket on the wall mounting bracket. (There is hook type fasteners to help mounting) 4. 1) Use a hammer to insert 4 plastic anchors into the 2) Align the inserted plastic anchors with the screw drilled holes on the wall. holes of the bracket. 3) Tighten the wall mounting bracket and the standard junction box bracket to a wall using four M4 L50 screws. 5. Connect the Ethernet cable to the Ethernet port (PoE In). 6. 1) Mount the AP on a bracket using a hole in the 2) Push the AP backward and tightly connect the lower of the AP. AP to the bracket. 7. Fasten the AP to the bracket using Torx security screws (each one on the left/right sides). Installing Anti-theft lock cable When installing the WEA412h AP in a public place, it is recommended to use anti-theft lock cables to prevent any loss. (An anti-theft lock cable can be purchased separately and a variety of products are available in the market.) Connect the anti-theft lock cable to the WEA412h AP. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help. Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. The 5150-5250 MHz band is restricted to indoor use only. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this devicemust accept any interference, including interference that may cause undesired operation of thedevice. Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes: (1) lappareil ne doit pas produire de brouillage, et (2) lutilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. FCC RF Radiation Exposure Statement:
This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 50 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. RSS-102 RF Exposure Lantenne (ou les antennes) doit tre installe de faon maintenir tout instant une distance minimum de au moins 50 cm entre la source de radiation (lantenne) et toute personne physique. Cet appareil ne doit pas tre install ou utilis en conjonction avec une autre antenne ou metteur. Electromagnetic Wave Suitability Notice Class B Equipment (For Home Use Broadcasting & Communication Equipment) This equipment is home use (Class B) electromagnetic wave suitability equipment and to be used mainly at home and it can be used in all areas. Regulatory Information Hereby, Samsung Electronics, declares that this WEA412h is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. The original Declaration of Conformity may be found at http://www.samsungdocs.com, go to Search Product and enter the model name. AEEE Ynetmeliine Uygundur (Compliant with WEEE)
(Pb)
(Hg)
(Cd)
(Cr6+)
(PBB)
(PBDE) 6 2 m m SJ/T11364
: GB/T26572